600 Series  
IdentiFlex 650  
Analog Addressable Control Panel  
Description  
The IdentiFlex 650 (IF650) is a full-featured Fire Alarm  
Control Panel (FACP) that can be configured to monitor  
and control both analog intelligent addressable devices  
and conventional hard-wired zones, providing maximum  
application flexibility. It is easily adapted to a new or retrofit  
installation, providing up to 2016 analog addressable  
points plus 96 conventional circuits. With the addition of a  
SmartLink™ network, the IdentiFlex 650 system can  
include multiple IF650s or other 600 Series fire alarm pan-  
els. The interactive operator’s display uses LED prompting  
for easy user operation and programming. The alphanu-  
meric display and keypad simplify field programming.  
Gamewell-FCI’s Smart Program II can be used to program  
the IF650 with a PC.  
ID650  
Features  
Analog/addressable and conventional input circuits.  
SmartStart™ self-programming logic.  
Fully modular.  
160-character, four-line display.  
One to 16 Signal Line Circuits (SLC) for up to 2016  
analog points.  
Polarity-insensitive SLC wiring (XP95 protocol).  
Automatic default response for increased survivability.  
1000-event history log.  
Integration of analog and hard-wired circuits allows the  
system engineer to customize the control panel based on  
the application. The CPU automatically senses system  
configuration to ensure that modules are correctly posi-  
tioned to speed installation and maintenance.  
IdentiFlex 650 software allows the system to be custom-  
ized to specific applications, such as cross-zoning and  
alarm verification.  
Digital SLC protocol.  
PC or front-panel programming.  
Password protected.  
Serial annunciator, remote display, and remote printer  
options.  
One-man, selectable-input walk test.  
Automatic drift compensation.  
Coded signaling.  
Day/night mode settings.  
Approved for Suppressant Releasing and Supervisory  
Service.  
Front-panel construction is designed to allow routine main-  
tenance of the system without disturbing the I/O modules.  
Multiple levels of password protection prevent unautho-  
rized use. The cabinet is designed with terminal strips for  
ease of installation and service.  
Operator’s Display  
The IdentiFlex 650 operator’s display supplies all the nec-  
essary keys and annunciation points to maintain and moni-  
tor the system. Alarm, Supervisory and Trouble conditions  
are all indicated on the operator’s display by dedicated  
LEDs and the internal sounder. The Acknowledge, Reset,  
and Signal Silence keys are easily identified on the display.  
UDACT compatible.  
Adjustable sensor sensitivity and temperature settings.  
SmartLink™ network compatible.  
An ISO 9000-2000 Company  
SIGNALING  
FM  
City of  
MEA  
132-95-E  
Approved  
APPROVED  
Chicago  
S521  
7165-1288:144 Approved  
SmartStart™ and SmartLink™ are trademarks of Honeywell International Inc.  
7170-1288:146  
High Rise  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
©2007 Honeywell International Inc. All rights reserved.  
Specifications are for information only, are not intended for installation pwurpwoswes,.ganadmareeswubejecllt-tofcchia.cngoemwithout notice. No responsibility is assumed by Gamewell-FCI for their use.  
CS-2005 Rev. A page 1 of 4  
The Reset key returns the control panel to idle mode after  
an alarm condition has been cleared. Trouble conditions  
that have been cleared will automatically return the control  
panel to idle mode if the problem has been corrected. Trou-  
ble conditions that have been acknowledged will resound  
the internal sounder if the condition is not corrected within  
a programmed time period.  
greatly expanding its use in retrofit applications (consult  
Gamewell-FCI Technical Support for specific wiring  
requirements).  
The CONVENTIONAL INPUT MODULE (CIM-8) occupies  
one bay and provides eight hard-wired input circuits for  
monitoring conventional detectors and contact-type  
devices. The CIM-8 monitors and reports each circuit’s  
analog status to the CPU as it distinguishes between  
detectors and contact devices and determines if two or  
more detectors are in alarm. Each input module uses one  
slot in the MPU bus and is supplied with its own display  
module. The display module provides LED annunciation of  
alarm and trouble conditions and has a switch (per circuit)  
for programming and bypass functions. The display has  
space for user-defined custom labels for each circuit.  
Beyond normal alarm and supervisory functions, the input  
circuits can be programmed for Remote Acknowledge,  
Reset, Signal Silence, and Release Abort switches. Cir-  
cuits can be wired for Style B, D, and E service and are  
capable of monitoring normally-closed devices.  
The Signal Silence key deactivates notification appliances.  
This function can be modified by user programming to  
operate only after a specified time period.  
There are three additional programmable switches avail-  
able to control application-specific operations. Keys for  
programming and bypass functions, along with LEDs for  
active and trouble conditions, are provided for the City  
Connection, and two signal circuits which are part of the  
Common Control section.  
Other Panel/System Components  
The IF650 COMMON CONTROL SECTION comprises the  
heart of the system. The common control section houses  
the main CPU and all system memory as well as providing  
local and remote communications and supervision. The  
common control contains the common system relays, two  
signal circuits, city tie, and optional EIA-232 port. All inter-  
action with the common control section is through the oper-  
ator’s display panel. Four relay circuits control auxiliary  
functions. The relays, rated at 10 Amps, are controlled by  
the main CPU. Two 24 VDC notification appliance circuits  
(NAC) are provided. The NACs can provide a steady or  
coded output. All circuits are power-limited per NEC 760  
and UL 864.  
The 600 Series UNIVERSAL SIGNAL MODULE (USM-8)  
occupies one bay and is a multifunctional eight-circuit out-  
put module. USM-8 modules communicate via the MPU  
bus and require one expansion slot each. The USM can be  
configured as 24 VDC signaling circuits. Modules are pro-  
grammed in two-circuit increments, making it possible to  
perform all four functions with a single module. Signal cir-  
cuits provide steady or coded outputs. All circuits are  
power-limited per NEC 760 and UL 864. Signal circuits can  
be wired in either Style Y or Z. Signal modules are supplied  
with their own display that provides LED annunciation of  
activation and trouble conditions and has a switch (per cir-  
cuit) for programming and bypass functions. The display  
has space for user-defined custom labels for each circuit.  
The 600 Series POWER SUPPLY (MPS-8) furnishes sys-  
tem operating and signaling power. The supply is equipped  
with a battery charger for maintaining the secondary power  
source. The power supply is monitored by the main CPU to  
ensure that adequate power levels are maintained. The  
power supply design allows for high efficiency while provid-  
ing precise power output. The battery charger is capable of  
operating with lead-acid batteries and maintaining up to 50  
AH batteries. Multiple auxiliary power supplies (APS-8)  
may be added to the system when additional power is  
required.  
The IF650 ANALOG INTERFACE MODULE (AAM95-  
1,2,4) occupies one bay and has from one to four circuits  
that can monitor and control up to 126 addressable/analog  
devices each for a total of 504 points per bay. Gamewell-  
FCI IF650 systems can be configured for up to 2016 points.  
The analog interface module has a dedicated microproces-  
sor which simultaneously communicates with the con-  
nected field devices and the main CPU. This feature allows  
the IF650 to maintain maximum communications speed  
throughout the system. Analog/addressable circuits can be  
wired as non-polarized in Style 4, 6, or 7. The communica-  
tions protocol provides for alarm verification per detector,  
detector adjustability and compensation, adjustable analog  
heat detector range (131°F to 194°F/55°C to 90°C), circuit  
isolation, and priority interrupts. Priority interrupts allow  
contact-type devices such as manual fire alarm stations to  
interrupt the polling cycle and transmit their addresses at  
any time during a polling sequence. The digital protocol  
allows the IF650 to operate on most types of field wiring,  
The 600 Series RELAY MODULE (RM-8) supplies eight  
NO/NC relays for control of auxiliary functions. The relays  
are controlled by the main CPU and are fully programma-  
ble. Each position on the MPU bus can accommodate a  
relay module. The relays are rated at 10 Amps and each is  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
CS-2005 Rev. A page 2 of 4  
www.gamewell-fci.com  
provided with a feedback point for positive confirmation of  
activation. Like all 600 Series expansion modules, the relay  
module reports activation.  
Addressable input-interface devices provide the means to  
communicate with cost-effective conventional devices in  
areas that do not require analog sensors.  
Addressable control-output devices serve as the interface  
between the analog circuits and building functions. The  
outputs are controlled via Control-by-Event software and  
can be programmed to respond to any event. The control  
devices can also be used as supervised remote signal cir-  
cuits.  
The 600 Series BUILDING CONTROL MODULE (BCM-8)  
provides an interface between the fire alarm and HVAC  
systems. Relays (rated at 10 A) are accompanied by feed-  
back points for positive confirmation of the programmed  
action. The BCM is available in eight-circuit modules that  
are monitored and controlled by the MPU bus which can  
monitor and control one expanded (i.e., eight-circuit) BCM  
per position. The display for the BCM provides LEDs for  
annunciation of relay state or feedback, and windows for  
user-defined custom labeling. In addition, the display for  
the BCM comes with a three position ON/OFF/AUTO  
switch per circuit for manual override of the programmed  
automatic functions.  
The IF650’s optional EIA-232 output expands the system’s  
display and control capability.  
Serial annunciators can be added to display system activity  
and control. The serial annunciator drivers provide the  
interface to graphic annunciators.  
An alphanumeric display (RAN2-RCS) can also be used for  
remote status and control. The alphanumeric display is  
designed to communicate over the serial communications  
network. It features a 160-character display and provides  
remote reset/acknowledge/silence keys. See RAN/SAN  
data sheets CS-2025 and CS-2027 for complete annuncia-  
tor details.  
Although the common control module is equipped with a  
city tie circuit which is suitable for most applications, an  
optional four-circuit CITY TIE MODULE (CTX-4) has been  
developed for applications that require multiple connec-  
tions. The city tie module connects to the MPU bus and is  
supplied with a display module. The CTX-4 can also be  
used for applications requiring a polarity-reversal output.  
The IF650 communicates with an EIA-232 printer either  
locally or remotely for documentation of system activity.  
The printer interface accepts serial communications from  
the control panel and provides a parallel output to the  
printer.  
There are two SYSTEM HOUSING CONFIGURATIONS  
available for the IF650 control panel. The four-bay cabinet  
(IF654) will accommodate four 600 Series modules in addi-  
tion to the common control, power supply, and batteries. An  
eight-bay cabinet (IF658) will accommodate eight 600  
Series modules in addition to the common control, power  
supply and batteries. The housings are designed with  
ample wiring space, conduit knockouts, and mounting  
options. The unit’s dead-front design allows all operation,  
programming, and user interface to take place without  
exposing the system modules or field wiring. Field-wiring  
terminals are mounted directly to the backbox for ease of  
installation and service. Modules can be removed for ser-  
vicing without disturbing field wiring.  
The IF650 can provide the required functions to control the  
releasing of bulk fire-suppressant materials. The IF650 is  
Listed for the following NFPA types of suppressant: 13  
Sprinkler, 15 Water Spray, 11 Low-Expansion Foam, 16  
Water Foam, 17 Dry Chemical, and 2001 Clean Agent.  
Applications  
The Gamewell-FCI IdentiFlex 650 Analog Addressable  
Control Panel is designed for small-to-large projects. The  
embedded CPU offers users unrivaled reliability with flexi-  
bility and value.  
The IF650 control panel is designed to incorporate the  
XP95 analog addressable sensors into an integrated life  
safety system which will meet today’s most stringent  
requirements.  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
CS-2005 Rev. A page 3 of 4  
www.gamewell-fci.com  
Specifications  
Ordering Information  
Common Control  
Standby Current:  
Alarm Current:  
Model  
IF654  
Description  
IdentiFlex 650 base analog/addressable  
system consisting of the following:  
0.275A.  
0.407A plus signaling circuit power,  
plus 0.002A for master box, or plus  
0.022A for reverse-polarity  
120 VAC, 2.0A  
IF650 common control that includes:  
- Main CPU  
Input Power:  
Auxiliary Output:  
S+/S–, A+/A–:  
- IF650 front display with LCD  
alphanumeric display  
- Bus Driver Module  
24 VDC, 2.0A combined maximum  
Common Relays:  
10A @ 30 VDC or 250 VAC  
- Common system relays  
Two NAC circuits and ribbon cables  
MPS-8 main power supply  
Four-bay cabinet assembly  
Supports up to 2016 points  
Signaling Circuits: 24 VDC nominal @ 2.0A per circuit  
Panel Dimensions:  
Four-bay cabinet:  
37.14" H x 24.0" W x 6.0" D  
(94.3 H x 61 W x 15.2 D cm)  
52.5" H x 24.0" W x 6.0" D  
(133.4 H x 61 W x 15.2 D cm)  
50 AH.  
Eight-bay cabinet:  
IF658  
IdentiFlex 650 base analog/addressable  
system consisting of the following:  
Battery Capacity:  
Battery Storage  
Dimensions:  
IF650 common control that includes:  
- Main CPU  
8.0" H x 14.25" W x 6.0" D  
(20.3 H x 36.2 W x 15.2 D cm)  
- IF650 front display with LCD  
alphanumeric display  
- Bus Driver Module  
Relative Humidity: 93% non-condensing  
Temperature Rating: 32° – 120°F (0° – 49°C)  
- Common system relays  
Two NAC circuits and ribbon cables  
MPS-8 main power supply  
Eight-bay cabinet assembly  
Supports up to 2016 points  
SYS-EXP8  
MPU bus expander module, complete  
with cables. Allows expansion for  
additional 600 Series Modules installed  
into a second eight-bay cabinet.  
CAB600-BD8  
Eight-bay cabinet with blank deadfront  
(no display windows). For housing auxil-  
iary power supplies (APS-8) with lock.  
Dimensions: 52.5" H x 24.0" W x 6.0" D  
(133.4 H x 61 W x 15.2 D cm)  
CAB600-8  
CAB600-4  
Eight-bay expansion cabinet assembly,  
with space for eight (8) MPU bus mod-  
ules. Includes backbox, deadfront cover,  
inner door assemblies, lock and key.  
Dimensions: 52.5" H x 24.0" W x 6.0" D  
(133.4 H x 61 W x 15.2 D cm)  
Four-bay expansion cabinet assembly,  
with space for four (4) MPU bus mod-  
ules. Includes backbox, deadfront cover,  
inner door assemblies, lock and key.  
Dimensions: 37.14" H x 24.0" W x 6.0" D  
(94.3 H x 61 W x 15.2 D cm)  
APS-8  
72122  
Eight-amp auxiliary power supply. Fits in  
one module expansion slot, includes one  
blank dress panel.  
IdentiFlex 650 Installation/Operating  
Manual.  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
CS-2005 Rev. A page 4 of 4  
www.gamewell-fci.com  

相关型号:

SYS161000FKX-10

SRAM Module, 1MX16, 100ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKX-12

x16 SRAM Module
ETC

SYS161000FKX-70

x16 SRAM Module
ETC

SYS161000FKX-85

SRAM Module, 1MX16, 85ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKXI-10

SRAM Module, 1MX16, 100ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKXI-12

SRAM Module, 1MX16, 120ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKXI-70

SRAM Module, 1MX16, 70ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKXI-85

SRAM Module, 1MX16, 85ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKXL-10

x16 SRAM Module
ETC

SYS161000FKXL-12

x16 SRAM Module
ETC

SYS161000FKXL-70

SRAM Module, 1MX16, 70ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC

SYS161000FKXL-85

SRAM Module, 1MX16, 85ns, CMOS, PDIP44, PLASTIC, DIP-44
MOSAIC