100ACMEA_15S4 [GAPTEC]

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated;
100ACMEA_15S4
型号: 100ACMEA_15S4
厂家: GAPTEC    GAPTEC
描述:

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated

文件: 总3页 (文件大小:1582K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
100ACMEA Series  
100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated  
AC-DC Converter  
100 Watt  
EMI for both Class I (with PE)  
and Class II (without PE)  
Over voltage protection (OVP)  
Meets EN60950, UL60950  
UL / IEC / EN 60601 3.1  
Edition & UL / IEC / EN 60950  
AM2 Safety Approvals  
Meets EN60601-1, ANSI/  
AAMI ES60601-1 standards  
(2 x MOOP)  
The 100ACMEA series is a compact size power converter offered by  
GAPTEC. It features universal input voltage, taking both DC and AC  
input voltage, low power consumption, high efficiency, high reliability,  
safer isolation. It offers good EMC performance, meets IEC/EN61000-4,  
CISPR22/EN55022, UL60950 and EN60950 standards, and is widely used  
in medical instrumentation and critical applications in commercial and  
industrial electronic equipment.  
High efficiency up to 93.5%  
Plastic case, meets UL94V-0  
Short circuit protection (SCP)  
Output power protection (OPP)  
With PFC Function >0.9  
<0.3W No Load Input Power  
(pending)  
Approval  
Model  
Power  
[W]  
Output voltage  
[V]  
Output current  
[A, max]  
Capacitive Load  
[µF, max]  
Efficiency*  
[@230VAC, %, typ]  
UL/CE  
UL/CE  
UL/CE  
UL/CE  
100ACMEA_12S4  
100ACMEA_15S4  
100ACMEA_24S4  
100ACMEA_48S4  
100  
100  
100  
100  
12  
15  
8.33  
6.667  
4.2  
6000  
5000  
2000  
330  
92.5  
92.5  
93  
24  
48  
2.1  
93.5  
* After 30 minutes of burn-in  
Input specifications  
Input voltage range  
Input frequency  
Input current  
Output specifications  
90-264 VAC (see derating curve)  
47~63Hz  
Item  
Test conditions  
Min Typ  
2
Max  
Units  
%
Output voltage  
accuracy  
Full load  
115VAC  
• 2A (max)  
230VAC  
• 1A (max)  
Line regulation  
Load regulation  
Ripple & noise*  
Hold-up time  
1
1
%
%
Inrush current  
(<2ms)  
115VAC  
• 45A (typ)  
230VAC  
• 90A (typ)  
10% to 100% load  
1% of Vout  
Leakage current  
Power factor  
< 0.1mA/264VAC (touch current)  
PF>0.9 at full load  
@90% Vout/115VAC  
10  
ms  
* Measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.  
Protection specifications  
Short circuit  
protection  
Protection type:  
Auto recovery, hiccup mode  
Example:  
100ACMEA_05S4  
100 = 100Watt; AC = AC-DC; MEA = series; 5Vout; S = Single Output;  
4 = 4kVAC  
Over-voltage  
protection  
Protection type:  
Auto recovery  
Over-power  
protection  
Protection type:  
Auto recovery, hiccup mode  
Note:  
Over-temperature  
protection  
Protection type:  
Auto recovery  
1. This product is not designed for use in critical life support systems, equipment  
used in hazardous environment, nuclear control systems or other such  
applications which necessitate specific safety and regulatory standards other  
the ones listed in this datasheet.  
2. All specifications valid at 230VAC input voltage, full load and +25°C after  
warm-up time unless otherwise stated.  
Page 1 of 3  
100ACMEA – Rev. 2017-1.0  
Specifications subject to change without notice.  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
100ACMEA Series  
100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated  
Common specifications  
Operating temperature range  
Storage temperature range  
Humidity (non-condensing)  
Cooling  
-30°C ~ +70°C (with derating)  
-30°C ~ +85°C  
95% MAX  
Free air convection  
0.05%/°C  
Temperature coefficient  
I/O-isolation voltage  
Input-Output: 4000VAC or 5656VDC  
Input-FG:  
Output-FG:  
2000VAC or 2828VDC  
1500VAC or 2121VDC  
Altitude during operation  
Atmospheric pressure  
EMC / EMI / Conducted and radiated EMI*  
EMC / EMS / ESD  
5000m  
56kPa to 106kPa  
EN55032 Conducted & Radiated Class B  
IEC/EN 61000-4-2  
IEC/EN 61000-4-3  
IEC/EN 61000-4-4  
IEC/EN 61000-4-5  
IEC/EN 61000-4-6  
IEC/EN 61000-4-8  
IEC/EN 61000-4-11  
EN61000-4-11  
Contact 4KV / Air 8KV  
perf. Criteria B  
perf. Criteria A  
perf. Criteria B  
perf. Criteria B  
perf. Criteria A  
perf. Criteria A  
perf. Criteria B  
EMC / EMS / Radiated Immunity  
EMC / EMS / Fast Transient  
EMC / EMS / Surge  
EMC / EMS / Conducted immunity  
EMC / EMS / PFMF  
EMC / EMS / Dips  
10V/m  
2kV  
1KV  
10Vr.m.s  
30A/m  
30% / 10ms  
>95% 5000ms  
EMC / EMS / Interruption  
Safety standards  
IEC60950, EN60950, UL60950  
Safety approvals  
UL / IEC / EN 60601 3.1rd Edition & UL / IEC / EN 60950 AM2  
UL94V-0  
Case material  
MTBF  
>250,000 h @ 25°C (MIL-HDBK-217F, Notice 1)  
10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.  
109.0 x 58.5 x 35.0 mm / Tolerance 5mm  
264 gr.  
Vibration  
Dimension  
Weight  
* Please secure the power supply unit to your metal case by using the four screw holes in the corners for either Class I or Class II equipment.  
Typical characteristics  
Derating graphs  
Power derating  
Page 2 of 3  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
100ACMEA – Rev. 2017-1.0  
Specifications subject to change without notice.  
100ACMEA Series  
100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated  
Block diagram  
Trim  
Mechanical dimensions  
PIN  
1
ø
Single  
AC IN (N)  
AC IN (L)  
PE  
1.2 0.1%mm  
1.2 0.1%mm  
1.2 0.1%mm  
1.2 0.1%mm  
2
3
4
ON / OFF  
(Provide +5Vdc Controlled)  
5
6
7
1.8 0.1%mm  
1.8 0.1%mm  
1.2 0.1%mm  
+DC OUT  
-DC OUT  
Trim  
Note:  
Please reserve the pin 4 hole on PCB.  
If the remote on/off function is not required, please  
connect the pin 4 circuit layout with pin6, or keep pin 4  
floating.  
Note:  
Unit: mm[inch]  
General tolerances: 0.50mm [ 0.020inch]  
Page 3 of 3  
GAPTEC-Electronic GmbH & Co. KG  
sales@gaptec-electronic.com – www.gaptec-electronic.com  
100ACMEA – Rev. 2017-1.0  
Specifications subject to change without notice.  

相关型号:

100ACMEA_24S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEA_48S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEB

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEB_12S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEB_24S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACMEB_48S4

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACP

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_05SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_12SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_24SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC

100ACPM_48SC

100W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated
GAPTEC