81977 [GENERAL]
Super Vu-Tron® Welding Cable; 超级VU- Tron®焊接电缆型号: | 81977 |
厂家: | GENERAL CABLE TECHNOLOGIES CORPORATION |
描述: | Super Vu-Tron® Welding Cable |
文件: | 总2页 (文件大小:120K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Industrial-Grade Cable
Mining
®
Super Vu-Tron Welding Cable
90ºCꢀ600ꢀVoltꢀUL/CSAꢀRHH/RHW
Product Construction:
Conductor:
ꢀ
•ꢀ 6ꢀ ꢀAWGꢀthroughꢀ4/0ꢀAWGꢀfullyꢀannealedꢀ
stranded bare copper per ASTM B-172 Class M
Jacket:
ꢀ
ꢀ
•ꢀ SuperꢀVu-Tron®, orange
•ꢀ ꢀTemperatureꢀrange:ꢀ-50ºCꢀtoꢀ+90ºC
Jacket Marking:
ꢀ
•ꢀ#6ꢀ-ꢀ#1ꢀAWG:ꢀCAROLꢀSUPERꢀVU-TRON®
WELDINGꢀCABLE–EXTRAꢀFLEXIBLEꢀ(UL)ꢀ600ꢀ
VOLTꢀ(-50°Cꢀtoꢀ+90°C)ꢀOILꢀRESISTANTꢀ
P-123-141ꢀMSHAꢀ(SIZE)ꢀCSAꢀ90°CꢀARCꢀ
WELDING CABLE FT-1
SUPER VU-TRON® WELDING CABLE—UL/CSA—CLASS M—34 AWG STRANDING
APPROX.
NET WT.
LBS/M'(S)
NOMINAL O.D.
INCHES
CATALOG
NUMBER
COND. SIZE
(AWG)
CONDUCTOR
STRAND
STD.
CTN.
mm
ꢀ
•ꢀ1/0ꢀ-ꢀ4/0ꢀAWG:ꢀCAROLꢀSUPERꢀVU-TRON®
WELDINGꢀCABLEꢀ(SIZE)ꢀEXTRAꢀFLEXIBLEꢀ
(UL)ꢀ600ꢀVOLTꢀ(-50°Cꢀtoꢀ+90°C)ꢀOILꢀ
RESISTANTꢀP-123-141ꢀMSHAꢀCSAꢀ90°Cꢀ
ARC WELDING CABLE FT-1 TYPE RHH OR
RHWꢀ(UL)ꢀ600VꢀFORꢀCTꢀUSE
6
4
660/34
1045/34
1666/34
2090/34
2640/34
3300/34
4180/34
5225/34
0.370
0.415
0.475
0.530
0.575
0.630
0.700
0.800
9.40
10.54
12.07
13.46
14.61
16.00
17.78
20.32
125
191
259
331
401
511
615
844
250'
250'
250'
250'
250'
250'
250'
250'
01768
01767
01766
01765
01764†
01763†
01762†
01761†
2
1
Applications:
ꢀ
ꢀ
•ꢀ ꢀSecondaryꢀvoltageꢀresistanceꢀweldingꢀleads
•ꢀ ꢀPowerꢀsupplyꢀapplicationsꢀnotꢀexceedingꢀ
600ꢀvoltsꢀAC
1/0
2/0
3/0
4/0
ꢀ
•ꢀ ꢀSizesꢀ1/0ꢀandꢀlargerꢀforꢀpermanentꢀwiringꢀ
inꢀconduitꢀorꢀtrayꢀofꢀ600Vꢀpowerꢀsupplies,ꢀ
hoists, cranes or other applications where
flexible power leads must be installed in
conduit, raceways or trays
(S) Actual shipping weight may vary.
†
TypeꢀRHH/RHWꢀ-ꢀ600VꢀforꢀCTꢀuse.
Features:
ꢀ
ꢀ
ꢀ
•ꢀ ULꢀListed
•ꢀ ꢀCSAꢀCertified
•ꢀ ꢀExcellentꢀflexibilityꢀtoꢀlastꢀlongerꢀinꢀflexꢀ
applications
•ꢀ ꢀAbrasion-resistant
WELDING CABLE AMPACITIES
SINGLE CONDUCTOR
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀ ꢀResistsꢀoilsꢀandꢀsolvents
•ꢀ ꢀRatedꢀ-50ºCꢀforꢀuseꢀinꢀcoldꢀenvironments
•ꢀ ꢀWeather-resistant
RequiredꢀCableꢀSizes:ꢀForꢀWeldingꢀCableꢀApplication
•ꢀ ꢀOzone-resistant
•ꢀ ꢀSafety-coloredꢀforꢀhighꢀvisibility
•ꢀ ꢀAssuredꢀlongerꢀserviceꢀlife,ꢀsavingꢀmoneyꢀ
in replacement costs, maintenance cost
and downtime
length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
AMPS
100
150
100'
150'
200'
250'
300'
350'
1/0
400'
1/0
4
4
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4
2
1
1/0
2/0
3/0
3/0
4/0
4/0
4/0
2
1
1/0
2/0
3/0
4/0
2
1
ꢀ
ꢀ
•ꢀ ꢀMSHAꢀapprovedꢀforꢀflameꢀresistance
•ꢀ ꢀSunlight-resistant
1/0
2/0
3/0
4/0
2/0
3/0
4/0
3/0
4/0
3/0
4/0
200
250
300
350
400
450
500
550
600
Industry Approvals:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀ ꢀULꢀListed
•ꢀ ꢀCSAꢀCertified
•ꢀ ꢀMSHAꢀApproved
•ꢀ ꢀMeetsꢀULꢀVerticalꢀFlameꢀTestꢀperꢀULꢀ854
•ꢀ RoHSꢀCompliant
Packaging:
ꢀ
•ꢀ ꢀ250'ꢀ(76.2ꢀm),ꢀ500'ꢀ(152.4ꢀm),ꢀandꢀ1000'ꢀ
(304.8ꢀm)ꢀreels
•ꢀ ꢀOtherꢀput-upsꢀavailableꢀonꢀspecialꢀorder
ꢀ
REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS
Theꢀtotalꢀcircuitꢀlengthꢀincludesꢀbothꢀweldingꢀandꢀgroundꢀleadsꢀ(Basedꢀonꢀ4-voltꢀdrop)ꢀ60%ꢀdutyꢀcycle.
Suggested Ampacities:
For 600 Volt In-Line Applications
These values for current-carryingꢀcapacityꢀareꢀbasedꢀonꢀaꢀcopperꢀtemperatureꢀofꢀ60°Cꢀ(140°F),ꢀanꢀambientꢀtemperatureꢀofꢀ
40°Cꢀ(104°F)ꢀandꢀyieldꢀloadꢀfactorsꢀofꢀfromꢀapproximatelyꢀ32%ꢀforꢀtheꢀNo.ꢀ2ꢀAWGꢀcableꢀtoꢀapproximatelyꢀ23%ꢀforꢀtheꢀ
No.ꢀ3/0ꢀAWGꢀcable,ꢀandꢀhigherꢀforꢀtheꢀsmallerꢀsizes.ꢀTheꢀsizesꢀofꢀcablesꢀgenerallyꢀusedꢀrangeꢀfromꢀNo.ꢀ2ꢀAWGꢀtoꢀ
No.ꢀ3/0ꢀAWG.ꢀInꢀactualꢀservice,ꢀtheꢀloadꢀfactorꢀmayꢀbeꢀmuchꢀhigherꢀthatꢀindicatedꢀwithoutꢀoverheatingꢀtheꢀcableꢀasꢀtheꢀ
ambientꢀtemperatureꢀwillꢀgenerallyꢀbeꢀsubstantiallyꢀlowerꢀthanꢀ40°C.
AWG
4/0
3/0
2/0
1/0
AMPERES
405
AWG
1
AMPERES
220
350
2
190
300
4
140
260
6
105
PerꢀStandards:ꢀICEAꢀS-19-81ꢀNEMAꢀWC-3ꢀPartꢀ8,ꢀ
Appendix J Ampacities for portable cable in accordance
withꢀNECꢀTableꢀ400.5(B).
May not be suitable for all installations per National
Electrical Code®.
28
Mining
Industrial-Grade Cable
Super Vu-Tron® EPR/CPE Diesel Locomotive Cable
90ºCꢀ2000ꢀVoltꢀDLO,ꢀULꢀRHH/RHWꢀ600ꢀVoltsꢀCSAꢀR90ꢀ1000ꢀVolt
Product Construction:
Conductor:
ꢀ
•ꢀ 1ꢀ 4ꢀAWGꢀthroughꢀ1111.1ꢀkcmilꢀstrandedꢀ
tinned annealed copper per AAR 589
Insulation:
ꢀ
ꢀ
ꢀ
•ꢀ Pꢀ remium-gradeꢀ90ºCꢀEP
Jacket:
•ꢀ ChlorinatedꢀPolyethyleneꢀ(CPE),ꢀblack
14 AWG - 1111.1 kcmil DLO - 2000 VOLT
Jacket Marking:
COND.
SIZE
CATALOG (AWG/
NUMBER kcmil)
NOM. INS.
CURRENT
AMPS
APPROX.
NET WEIGHT
LBS/MFT(S)
•ꢀ Sꢀ IZESꢀ14ꢀTHROUGHꢀ1ꢀAWGꢀ-ꢀCAROLꢀ
SUPER VU-TRON®ꢀ(SIZE)ꢀ(STRANDING)ꢀ
90°CꢀDLOꢀ2000ꢀVOLTSꢀP-7K-123040ꢀ
MSHAꢀCSAꢀR90ꢀ1000Vꢀ(UL)ꢀRHHꢀORꢀRHWꢀ
600ꢀVOLTS
THICKNESS
NOMINAL O.D.
COND.
STRAND
INCHES
mm
INCHES
mm
(1)
(2)
14
12
19/0.0147
19/0.0185
27/24
0.045
0.047
0.045
0.060
0.060
0.060
0.060
0.080
0.080
0.080
0.080
0.080
0.095
0.095
0.095
0.095
0.120
0.120
0.120
0.120
0.140
1.14
1.19
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
3.05
3.05
3.05
3.05
3.56
0.21
0.24
0.26
0.34
0.40
0.46
0.52
0.65
0.69
0.73
0.81
0.87
1.00
1.06
1.10
1.23
1.34
1.45
1.50
1.67
1.84
5.44
6.10
25
35
34
45
81914
81912
81910
81908
81906
81904
81902
81901
81911
81920
81930
81940
81926
81931
81937
81944
81953
81964
81977
81929*
81999
ꢀ
•ꢀ Sꢀ IZESꢀ1/0ꢀTHROUGHꢀ646.4ꢀ-ꢀCAROLꢀ
SUPERꢀVU-TRON®ꢀ(SIZE)ꢀ90°CꢀDLO
2000ꢀVOLTSꢀP-7K-123040ꢀMSHAꢀCSAꢀR90ꢀ
1000Vꢀ(-40°C)ꢀFT-1ꢀ(UL)ꢀRHHꢀORꢀRHWꢀ600ꢀ
VOLTSꢀSUNLIGHTꢀRESISTANTꢀFORꢀCTꢀ
USE
NOTE:ꢀ535.3ꢀANDꢀ646.4ꢀkcmilꢀPRINTEDꢀ
(UL)ꢀRHHꢀORꢀRHWꢀ2000ꢀVOLTS
•ꢀ Sꢀ IZESꢀ777.7ꢀTHROUGHꢀ1111.1ꢀkcmil -
CAROL SUPER VU-TRON® C(UL) TYPE
RHW-2 2KV VW-1 FOR CT USE TYPE DLO
2000Vꢀ90°CꢀP-102ꢀMSHA
30
40
40
55
10
6.60
60
8
37/24
8.64
55
80
95
6
61/24
10.16
11.68
13.21
16.51
17.53
18.54
20.57
22.10
25.40
26.92
27.94
31.24
34.04
36.83
38.10
42.42
46.74
75
105
140
190
220
260
300
350
405
467
522
591
652
728
815
904
1014
1115
145
4
105/24
154/24
224/24
280/24
329/24
456/24
551/24
650/24
777/24
925/24
1110/24
1332/24
1609/24
1924/24
2299/24
2745/24
95
205
2
130
150
170
195
225
260
296
326
362
400
445
493
546
602
635
295
ꢀ
1
440
1/0
515
Applications:
2/0
580
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀ Dꢀ ieselꢀelectricꢀlocomotives
•ꢀ Tꢀ elecomꢀpowerꢀsupply
•ꢀ Mꢀ iningꢀandꢀearth-movingꢀequipment
•ꢀ Sꢀ hipyards
•ꢀ Mꢀ otorꢀleads
•ꢀ Wꢀ hereꢀflexibleꢀpowerꢀleadsꢀmustꢀbeꢀ
installed in conduit or raceways
3/0
770
4/0
930
262.6
313.3
373.7
444.4
535.3
646.4
777.7
929.2
1111.1
1130
1295
1545
1820
2195
2560
3050
3625
4354
Features:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
•ꢀ 90ºCꢀtemperatureꢀrating
•ꢀ Eꢀ xcellentꢀimpactꢀandꢀabrasionꢀresistance
•ꢀ Rꢀ esistsꢀoils,ꢀacids,ꢀalkalies,ꢀheat,ꢀflame
•ꢀ Fꢀ lexibleꢀtinnedꢀcopperꢀstranding
•ꢀ Fꢀ T4ꢀuponꢀrequest
•ꢀ Sꢀ unlight-resistant
Industry Approvals:
ꢀ
ꢀ
•ꢀ ULꢀListed
•ꢀ Acceptedꢀforꢀlistingꢀasꢀflame-resistantꢀ
by MSHA
•ꢀ CSAꢀR90
•ꢀ RoHSꢀCompliant
Dimensions and weights are nominal; subject to industry tolerances.
(1) Ampacitiesꢀbasedꢀonꢀ90°Cꢀconductorꢀandꢀ30°CꢀambientꢀtemperatureꢀbasedꢀonꢀtheꢀNationalꢀElectricalꢀCode® for not more
ꢀ
ꢀ
than three current-carrying conductors in raceway, cable or earth.
(2) Ampacitiesꢀbasedꢀonꢀsingle-conductorꢀinꢀfreeꢀair,ꢀ90°Cꢀconductorꢀtemperatureꢀandꢀanꢀambientꢀairꢀtemperatureꢀofꢀ30°C,ꢀinꢀ
accordance with National Electrical Code® (NEC).
(S) Actual shipping weight may vary.
* Non-stock item
Packaging:
ꢀ
•ꢀ Lꢀ engthsꢀcutꢀtoꢀorder
29
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明