083171-1-02N [GRAYHILL]
Rotary Switch, Wire Terminal, Flat Shaft Type Actuator, Panel Mount-threaded,;型号: | 083171-1-02N |
厂家: | GRAYHILL, INC |
描述: | Rotary Switch, Wire Terminal, Flat Shaft Type Actuator, Panel Mount-threaded, 开关 |
文件: | 总2页 (文件大小:376K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Special Function Rotary Switches
SERIES 08,09,42,44,50
Spring Return
FEATURES
• Hold-To-Test, Hold-To-Calibrate,
And Other Momentary Applications
• Choice of Configurations, Ratings,
Styles and Circuitry
• 10,000 Cycles of Operation
DESCRIPTION
A spring return rotary switch has 1 or more momentary positions. Maintaining contact at momentary
positions requires rotational force. Releasing the force allows the mechanism to return the contact
to a normal, or detent, position.
DIMENSIONS
Series 08 & 09
Series 50
Equivalent to Series 50 Standard Switches
.500 .015
(12,7 0,38)
DIA.
DIM. A + .046 (1,17)
–.020 (0,51)
DIM. B REF.
STUD PROJECTION
.320 .015 (8,13 0,38)
CIRCLE OF CENTERS
For all other dimensions and
specifications, see Standard
Switch pages.
COMMON
36°
3°
No. of
Decks
Dim
A
Dim
B
Series 42 & 44
DIM. A + .046 (1,17)
–.020 (0,51)
No. of
Decks
Dim.
A
1
2
3
4
5
6
.960 (24,38) .062 (1,57)
1.228 (31,19) .062 (1,57)
1.496 (38,0)
1.764 (44,81) .062 (1,57)
2.032 (51,61) .062 (1,57)
2.550 (64,77) .312 (7,92)
.062 (1,57)
1
2
3
1.025 (26,04)
1.371 (34,82)
1.717 (43,61)
For all other dimensions and
specifications, see Standard
Switch pages.
For all other dimensions and
specifications, see Standard
Switch pages.
CONFIGURATIONS
SELECTING A SWITCH
OPTIONS
This configuration indicates a counterclockwise
force is required to hold the switch at position
#1. “M” indicates a momentary position
counterclockwiseof“D”and"D", detentedones.
1. Select a Configuration: The total number of
positions always includes the 2 basic positions.
A (4) position switch of DDDDM configuration
wouldhave3detentpositionscounterclockwise
of the momentary position.
Watertight panel seal; Multi-pole switches that
exceed the limits noted in the Selector Chart;
Series 50 MD or DM configurations in Military
styles; Series 08, 09, & 44 in MMMDMMM, and
in MMDDMM, and in MMMMMD.
Positions
1
2
3
M
D
D
Not available through Distributors
2. Select Series, Angle of Throw, and Style:
See the Choices Chart. The basic switch
description, series, and throw are as follows:
Releasingthisforcebreakscontactwithposition
#1 and returns the switch to #2. Normal rotary
switch detent action occurs when the switch is
rotated between position #2 and #3.
ORDERING INFORMATION
Create the part number using this example.
1/2", 1/4 Amp, multi-deck
1", 1 Amp, multi-deck
08 = 36° 09 = 30°
42 = 36° 44 = 30°
All of the configurations (except MDM) list a
basic 2 position arrangement which is shown in
italics.Example:MDDDDDorDDDDDM.Several
positions can be added during the switch
constructionatthefactory;but,anyconfiguration
must always contain the 2 basic positions.
1/2", 200 mA, single deck 50 = 36°
Stem number from chart
(4 or 5 digits)
Number of Decks
Electrical ratings are the same as those of the
conventional switches with the exception of life.
Life is limited to 10,000 cycles of operation
(25,000 cycles for Series 50) due to the spring
arrangement. Dimensions are the same as for
conventional types except for the shaft flat
orientation of the 3, 4, 5, and 6 pole, Series 09
and 44 in the DDDDDM configuration (see
chart).
Number of Poles/Deck
093103-2-045
Type of Contacts:
S=Shorting
N=Non-Shorting
Number of Positions/Pole
3. Select Poles & Positions Per Pole: If you
do not find the poles and positions per pole you
need in one series, try another or contact the
factory. If the behind panel length is a problem,
select a multi-pole type instead of a single deck.
Exception: Numbers beginning with 5 are
already complete part numbers.
Grayhill, Inc.
• 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Special Function Rotary Switches
CHOICES AND LIMITATIONS
Con-
figur-
ation
Conven-
tional
Switch
Description
Of
Spring Return
Stem Number
(See Ordering Info.)
No.
Of
Decks
Poles
Per
Deck
Positions Per
Pole & Contact
Type
Location Of
UniquePosition,
Detent or Momentary
Term.
Opp.
Flat**
Style
08A36
Standard
08317
1 to 6
1 to 3
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M 5
M 5, 10
5
5
1 to 6
1 to 3
1 or 2
1
1
2
3
02 to 06 (N or S)
02 to 06 (N or S)
02 to 04 (N or S)
02 or 03 (N or S)
02 (N or S)
M 6
M 6, 12
M 4, 8, 12
M 3, 6, 9, 12
M 2, 4, 6, 8, 10, 12
6
6
4
3
2
09A30
Standard
09310
4
DDDDDM
1
5 or 6
42A36
42M36
44A30
44M30
08A36
Standard
Military
42349
42352
44346
44350
08319
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M 5
M 5, 10
5
5
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M 5
M 5, 10
5
5
Standard
Military
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M 6
M 6, 12
6
6
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M 6
M 6, 12
6
6
Standard
1 to 6
1 to 3
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M 1
M 1, 6
1
1
1 to 6
1 to 3
1 or 2
1
1
2
3
02 to 06 (N or S)
02 to 06 (N or S)
02 to 04 (N or S)
02 or 03 (N or S
02 (N or S)
M 1
M 1, 7
M 1, 5, 9
M 1, 4, 7, 10
M 1, 3, 5, 7, 9, 11
1
1
1
1
1
09A30
Standard
09312
4
1
5 or 6
MDDDDD
1 to 3
1
1
1
2
3
02 to 06 (N or S)
02 to 06 (N or S)
02 to 04 (N or S)
M 1
M 1, 7
M 1, 5, 9
1
1
1
09M30
42A36
42M36
44A30
44M30
Military
09356
42350
42353
44312
44351
Standard
Military
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M 1
M 1, 6
1
1
1 to 3
1
1
2
02 to 05 (N or S)
02 to 05 (N or S)
M 1
M 1, 6
1
1
Standard
Military
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M 1
M 1, 7
1
1
1 to 3
1
1
2
02 to 06 (N or S)
02 to 06 (N or S)
M 1
M 1, 7
1
1
50A36
50P36
8A36
Std., Solder Lug
Std., PC Mount
Standard
503265-1-03N*
503267-1-03N*
08316
1
1
1
1
03N
03N
D 2
D 2
2
2
1 to 6
1 to 3
1
2
03 (N or S)
03 (N or S)
D 2
D 2, 7
2
2
1 to 6
1 to 3
1 or 2
1
1
2
3
4
03 (N or S)
03 (N or S)
03 (N or S)
03 (N or S)
D 2
D 2, 8
D 2, 6, 10
D 2, 5, 8, 11
2
2
2
2
9A30
Standard
09311
MDM
42A36
42M36
44A30
44M30
Standard
Military
42348
42351
44345
44349
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D 2
D 2, 7
2
2
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D 2
D 2, 7
2
2
Standard
Military
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D 2
D 2, 8
2
2
1 to 3
1
1
2
03 (N or S)
03 (N or S)
D 2
D 2, 8
2
2
*This is a complete (not stem) part number.
**Terminal opposite shaft flat when switch
is in its unique (detent or momentary)
position.
For prices and discounts, contact a local Sales
Office,anauthorizedlocalDistributor,orGrayhill.
AvailablefromyourlocalGrayhillDistributor
Grayhill, Inc.
• 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明