Green-Mode PWM Controller below 100mW Standby Power  
Features  
Description  
Current mode PWM control  
The GR8830 is a highly-integrated, low startup  
current, current mode PWM controller with  
Green-mode function. This function enables the  
power supply to easily meet even the strictest  
power conservation requirements. The integrated  
functions also include the leading-edge blanking  
Standby power below 100mW solution  
Under voltage lockout (UVLO)  
Non-audible-noise green-mode control  
Programmable switching frequency  
Internal leading-edge blanking  
Internal slope compensation  
of  
the current sensing, internal slope  
Internal soft start  
compensation, cycle-by-cycle peak current  
limiting, and soft start. OLP, OCP and OVP  
provide protection performance for fault conditions.  
For protecting the external power MOSFET from  
being damaged by supply over voltage, the  
GR8830 OUT pin voltage is clamped to about  
13V.  
Gate output voltage clamp  
Jitter and soft driving for reducing EMI  
Over-voltage protection (OVP) on VCC pin  
Over-load protection (OLP)  
Over-current protection (OCP) on CS pin  
Over-temperature protection (OTP)  
The GR8830 improves the performance and  
reduces the cost of power supplies. It is with both  
DIP-8 and SOT-26 package.  
Applications  
Switching AC/DC power adaptor  
Battery charger  
Open-frame SMPS  
Ordering and Marking Information  
DIP-8  
SOT-26  
Grenergy OPTO Inc. reserves the right to make changes to improve reliability or manufacture ability without notice, and  
advise customers to obtain the latest version of relevant information to verify before placing orders.  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
1
GR8830  
Pin Configuration  
Pin Description  
Pin No.  
Name  
GND  
COMP  
RT  
Function  
1
2
3
4
5
6
Ground  
Voltage feedback pin, by connecting a photo-coupler to control the duty cycle  
Connecting a resistor to ground to set the switching frequency  
Current sense pin, connect to sense the MOSFET current  
Power Supply pin  
CS  
VCC  
OUT  
The output driver for driving the external MOSFET  
Note: Pin No. is only for SOT-26 package, DIP-8 see Pin Configuration.  
Absolute Maximum Ratings  
Supply voltage VCC --------------------------------------------------------------------------------------------------------- 30V  
COMP, RT, CS --------------------------------------------------------------------------------------------------------  
OUT ------------------------------------------------------------------------------------------------------------ 0.3 ~ Vcc+0.3V  
Junction temperature ---------------------------------------------------------------------------------------------------- 150  
0.3 ~ 7V  
Operating ambient temperature -----------------------------------------------------------------------------  
Storage temperature range -------------------------------------------------------------------------------  
20 ~ 85  
65 ~ 150  
SOT-26 package thermal resistance ----------------------------------------------------------------------------  
250 /W  
Power dissipation (SOT-26, at ambient temperature = 85  
Power dissipation (DIP-8, at ambient temperature = 85  
)
------------------------------------------------ 250mW  
--------------------------------------------------- 650mW  
)
Lead temperature (All Pb free packages, soldering, 10 sec) --------------------------------------------------  
ESD voltage protection, human body model -------------------------------------------------------------------------  
ESD voltage protection, machine model ----------------------------------------------------------------------------  
260  
2KV  
200V  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
2
GR8830  
Recommended Operating Conditions  
Item  
Min.  
12  
Max.  
25  
Unit  
V
Supply voltage VCC  
Switching frequency  
50  
130  
KHz  
Block Diagram  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
3
GR8830  
Electrical Characteristics (VCC = 15.0V and T  
A
= +25  
unless otherwise specified)  
Parameter  
Pin  
Min.  
Typ.  
Max.  
Unit  
SUPPLY VOLTAGE  
Startup current  
5
5
5
8
15  
uA  
mA  
mA  
Operating current (with 1nF load on OUT pin), Vcomp = 0V  
1.5  
2.5  
Operating current (with 1nF load on OUT pin), Vcomp = 2.5V  
Operating current (with 1nF load on OUT pin), protection tripped  
5
0.65  
mA  
(OLP, OVP)  
UVLO (off)  
5
5
5
6.8  
10.8  
27  
V
V
V
UVLO (on)  
OVP level on VCC pin  
26  
28  
5
VOLTAGE FEEDBACK  
Open loop voltage, COMP pin open  
2
2
V
V
Green-mode threshold voltage  
1.8  
CURRENT SENSING  
Maximum input voltage, Vcs (off)  
4
4
4
4
0.85  
1
0.90  
350  
0.95  
V
nS  
M
Leading-edge blanking time  
Input impedance  
Delay to output  
100  
nS  
OSCILLATOR  
Frequency (RT = 100K  
Jitter frequency  
)
3
3
3
3
3
60  
20  
65  
6
70  
KHz  
%
Green mode frequency (RT = 100K  
Temp. stability 40°C ~ 110°C)  
)
25  
3
KHz  
%
Voltage stability (Vcc = 11V ~ 25V)  
1
%
GATE DRIVER OUTPUT  
Output low level, VCC = 15V, Io = 10mA  
Output high level, VCC = 15V, Io = 10mA  
Rising time, load capacitance = 1000pF  
Falling time, load capacitance = 1000pF  
VGATE-clamp (at VCC = 20V )  
6
6
6
6
6
1
V
V
8
200  
80  
nS  
nS  
V
12  
13  
14  
OLP  
OLP trip level, Vcomp (OLP)  
-
-
3.5  
60  
V
OLP delay time (note), Fs = 65KHz  
mS  
PWM Section  
Maximum duty cycle  
-
70  
75  
80  
%
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
4
GR8830  
Typical Performance Characteristics  
20.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
5
GR8830  
Application Information  
Start-up Current  
Where R is the resistor connected at RT pin.  
100Kohm resistor results in 65KHz switching  
frequency. The recommended range of oscillation  
A
The typical start-up current is around 8uA. Very low  
start-up current allows the PWM controller to  
increase the value of start-up resistor and then  
reduce the power dissipation on it.  
frequency is 50 KHz~130 KHz  
.
Green-Mode Operation  
Under-voltage Lockout (UVLO)  
When the load decreases to an extent, the  
frequency of the controller will decrease so as to  
reduce the system power consumption. The  
minimum frequency is about 21 KHz, which is  
A hysteresis UVLO comparator is implemented in  
GR8830, once the VCC rises above UVLO (on)  
voltage, the controller starts to switch with a soft  
start period. It will continue to operate unless the  
voltage drops below UVLO (off) voltage. It’s  
operation is shown in Fig. 7  
outside the audio range  
.
Leading-edge Blanking (LEB)  
Each time the power MOSFET is switched on, a  
turn-on spike will inevitably occur at the sense  
resistor. To avoid fault trigger, a 350ns leading-edge  
blanking time is built in. Conventional RC filtering  
can therefore be omitted. During this blanking  
period, the current-limit comparator is disabled and  
can not switch off the gate driver.  
Internal Slope Compensation  
Fig. 7  
A built-in slope compensation circuit is constructed  
in GR8830. When the switch is on, a ramp voltage is  
added to the sensed voltage across the CS pin,  
which helps to stabilize the system and prevent  
Soft Start  
During initial power on, the GR8830 provides soft  
start function. It effectively suppresses the start up  
peak current to reduce the power MOSFET drain  
voltage especially at high line.  
sub-harmonic oscillations  
.
Oscillator  
The maximum duty-cycle of internal oscillator is  
limited about 75% to avoid the transformer  
saturation.  
The frequency of the oscillator is  
decided by an external resistor connected from RT  
pin to ground.  
fosc= 6500KHz/R (Kohm)  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
6
GR8830  
Application Information (Cont.)  
Over-load Protection (OLP)  
VCC  
The controller has over load protection function.  
An internal circuit detects the load level, when the  
load is larger than a threshold and the condition  
lasts more than 60ms, the gate output will keep low  
level. Then VCC decreases below UVLO off level,  
the controller resets again. Fig. 8 shows the  
waveform of the OLP operation.  
OVP Tripped  
OVP Level  
UVLO(on)  
UVLO(off)  
t
OUT  
Non-Switching  
Switching  
Switching  
t
VCC  
Fig. 9  
Gate Clamp/Soft Driving  
UVLO(on)  
(off)  
UVLO  
OLP  
(off )  
OLP Counter Reset  
Driver is clamped to 13V by an internal clamping  
circuit. Those damages usually come from  
undesired over-voltage gate signals. Under the  
conditions listed below, the gate output will turn off  
immediately to protect the power circuit. The  
GR8830 also has soft driving function to minimize  
EMI.  
t
t
t
COMP  
OLP delay time  
3.5 V  
OLP trip Level  
OUT  
Switching  
Non - Switching  
Switching  
VCC Mode Operation  
In order to avoid the output voltage shut down by  
load changing from full to no load, the GR8830 is  
built-in the VCC mode function. When the load from  
full changes to no load, the output voltage will  
overshoot and pull low the COMP pin by feedback  
loop. Thus the duty will disappear and no power  
delivers to the secondary. If there is without any  
mechanism to prevent this situation, the VCC pin  
voltage will down to UVLO off and the IC will re-start  
again. In the GR8830, before the VCC is down to  
UVLO off, it will force the OUT pin outputs the  
specified duty to pull the VCC higher than UVLO off.  
The operation is shown in Fig.10.  
Fig. 8  
Over-voltage Protection (OVP) on VCC  
To prevent power MOSFET from being damaged,  
the GR8830 is implemented an OVP function on  
VCC. When the VCC voltage is higher than the OVP  
threshold voltage, the output gate driver circuit will  
be shut down immediately to stop the switching of  
power MOSFET. The VCC OVP function is an  
auto-recovery type protection. If OVP happens, the  
pulses will be stopped and recover at the next  
UVLO on. The GR8830 is working in a hiccup mode  
as shown in Fig. 9.  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
7
GR8830  
Application Information (Cont.)  
The VCC mode function is used to prevent the  
output re-start again when load changes. So never  
let the system operate on the VCC mode at no load.  
The system should operate on burst mode,  
otherwise the input power maybe become larger.  
VCC  
VCC mode  
Burst mode  
VCC mode(off)  
VCC mode(on)  
UVLO(off)  
t
t
t
LOAD  
Full load  
OUT  
Switching  
Fig. 10  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
8
GR8830  
Typical Application Circuit  
C C V  
D N G  
5
1
t
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
9
GR8830  
Package Information  
SOT-26  
SYMBOL  
MILLIMETERS  
INCHES  
MIN.  
MAX.  
1.45  
0.15  
1.30  
0.50  
0.22  
3.10  
3.00  
1.80  
MIN.  
MAX.  
0.057  
0.006  
0.051  
0.020  
0.009  
0.122  
0.118  
0.071  
A
A1  
A2  
b
0.00  
0.90  
0.30  
0.08  
2.70  
2.60  
1.40  
0.000  
0.035  
0.012  
0.003  
0.106  
0.102  
0.055  
c
D
E
E1  
e
0.95 BSC  
1.90 BSC  
0.037 BSC  
0.075 BSC  
e1  
L
0.30  
0o  
0.60  
8 o  
0.012  
0o  
0.024  
8 o  
Note: 1. Followed from JEDEC TO-178 AB.  
2. Dimension D and E1 do not include mold flash, protrusions or gate burrs. Mold flash, protrusions or  
gate burrs shall not exceed 10 mil per side.  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
10  
GR8830  
Package Information  
DIP-8  
SYMBOL  
MILLIMETERS  
INCHES  
MIN.  
MAX.  
5.33  
MIN.  
MAX.  
0.210  
A
A1  
A2  
b
0.38  
2.92  
0.36  
1.14  
0.20  
9.01  
0.13  
7.62  
6.10  
0.015  
0.115  
0.014  
0.045  
0.008  
0.355  
0.005  
0.300  
0.240  
4.95  
0.56  
1.78  
0.35  
10.16  
0.195  
0.022  
0.070  
0.014  
0.400  
b2  
c
D
D1  
E
8.26  
7.11  
0.325  
0.280  
E1  
e
2.54 BSC  
7.62 BSC  
0.100 BSC  
0.300 BSC  
eA  
eB  
L
10.92  
3.81  
0.430  
0.150  
2.92  
0.115  
Note: 1. Followed from JEDEC MS-001 BA.  
2. Dimension D, D1 and E1 do not include mold flash or protrusions. Mold flash or protrusions shall not  
exceed 10 mil.  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
11  
GR8830  
Carrier Tape & Reel Dimensions  
SOT-26  
Application  
SOT-26  
A
H
T1  
C
d
D
W
E1  
F
8.4+2.00 13.0+0.50  
178.0 2.00 50 MIN.  
1.5 MIN. 20.2 MIN. 8.0 0.30 1.75 0.10 3.5 0.05  
-0.00  
-0.20  
D0  
P0  
P1  
P2  
D1  
T
A0  
B0  
K0  
1.5+0.10  
-0.00  
0.6+0.00  
-0.40  
4.0 0.10  
4.0 0.10 2.0 0.05  
1.0 MIN.  
3.20 0.20 3.10 0.20 1.50 0.20  
(mm)  
Application  
SOT -26  
Carrier Width  
Cover Tape Width  
Devices Per Reel  
8
5.3  
3000  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
12  
GR8830  
Taping direction information  
SOT-26  
Direction of feed  
Direction of feed  
AAA  
AAA AAA  
AAA AAA AAA AAA  
_______________________________________________________________________  
Grenergy OPTO, Inc. reserves the right to make corrections, modifications, enhancements, improvements, and other changes  
to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the  
latest relevant information before placing orders and should verify that such information is current and complete.  
2010.10 Ver. 1.1 Copyright Grenergy OPTO, Inc. www.grenergy-ic.com  
13  

相关型号:

GR8830CG

Green-Mode PWM Controller below 100mW Standby Power
GRENERGY

GR8830CL

Green-Mode PWM Controller below 100mW Standby Power
GRENERGY

GR8830JG

Green-Mode PWM Controller below 100mW Standby Power
GRENERGY

GR8830JL

Green-Mode PWM Controller below 100mW Standby Power
GRENERGY

GR8835A

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8835ACG

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8835ACI

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8835AJG

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8835AJI

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8836

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8836CG

Green-Mode PWM Controller with Integrated Protections
GRENERGY

GR8836JG

Green-Mode PWM Controller with Integrated Protections
GRENERGY