2CLSA1B4-4 [HONEYWELL]
Snap Acting/Limit Switch;型号: | 2CLSA1B4-4 |
厂家: | Honeywell |
描述: | Snap Acting/Limit Switch 开关 |
文件: | 总6页 (文件大小:604K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Interactive Catalog Supplements Catalog PDFs
If you need detailed product information, or help choosing the right
product for your application, see our Interactive Catalogꢀ Use the
Interactive Catalog to access the most complete and up-to-date
information availableꢀ
Sensing and Control
In t e ra c t ive
Ca t a lo g ...
The Interactive Catalog provides an extensive collection of product
specifications, application data, and technical literature that can be
searched based on criteria you selectꢀ
Click this icon to try
the Interactive Catalogꢀ
This PDF catalog information was published in November 2000ꢀ
Sensing and Control
Honeywell Incꢀ
11 West Spring Street
Freeport, IL 61032
www.honeywell.com/sensing
Limit and Enclosed Switches
CLS Series
Momentary Cable Pull Limit Switches: For Signaling Applications
FEATURES
ɀ Offered in Single Head and Duplex
Head versions
ɀ Optional direct acting contacts enhance
reliability
ɀ Duplex Head switches cover up to 400
ft. cable spans (200 ft. in each direction)
ɀ Single Head switches have one normally
open auxiliary contact, while Duplex
Head switches have up to three
normally open and two normally closed
auxiliary contacts
ɀ Four conduit opening thread size
options: 1/2-14 NPT, 20mm, PF1/2 and
PG13.5
ɀ Compact size of Single Head switches
fits into tight spaces
MOMENTARY (CONTACT SWITCH) OPERATING HEAD
ɀ Sealed to NEMA 1, 3, 4 and 13
ɀ Smart Distributed System output
available on Duplex version for
monitoring only
Momentary CLS Series Cable Pull Limit Switches are designed for signaling applications;
they are not to be used as emergency stop devices. (For emergency stop applications, see
the Maintained Cable Pull Limit Switches in the Safety Products catalog.)
ɀ UL listed
Whenusingdirectactingcontacts,MomentaryCablePullLimitSwitchesprovideameansto
manually force disconnection of a normally closed control circuit by pulling on an attached
cable. Momentary switches cause contact transfer if the cable is manually pulled and held.
When the cable is released, switch contacts return to their original state. Momentary
switches have either direct-acting contacts or snap-action contacts.
ɀ CSA certified
ɀ CE certified
ɀ Temperature range: –1° to 70°C (30° to
158°F)
ɀ Available with indicators
ɀ Duplex versions available with high
visibility pilot light
Cable length may be up to 200 ft. in a straight line for Single Head switches, and up to 400 ft.
(200 ft. in each direction) for Duplex Head switches.
TYPICAL APPLICATIONS
ɀ Conveyors
ɀ Packaging machinery
ɀ Assembly lines
ɀ Process equipment
ɀ Transfer lines
TYPICAL DUPLEX HEAD SWITCH INSTALLATION
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
A65
Limit and Enclosed Switches
CLS Series
Momentary Cable Pull Limit Switches: For Signaling Applications
TECHNICAL DATA CLS SERIES SPECIFICATIONS
Electrical
Rate thermal current
Rate insulation voltage
Impulse voltage
I
th = 10 A
Ui = 660 VAC/660 VDC
imp = 2.5 kV
< 25 milliohms
U
Contact resistance
Operating rating
AC15
U = 600 V: I = 1.2 A
U = 240 V: I = 3 A
U = 120 V: I = 6 A
U = 250 V: I = 0.27 A
U = 24 V: I = 2.8 A
DC13
UL/CSA
A600/Q300
Mechanical
Protection class
Mechanical life
NEMA 1, 3, 4 and 13
5
10 operations maximum
Temperature Range
Terminal identification
Head/housing material
–1° to 70°C (30° to 158°F)
Numbering to EN50013
Zinc die cast
CABLE PULL SWITCH
CHARACTERISTICS
An additional auxiliary switch is also avail- SMART DISTRIBUTED SYSTEM OUTPUT
able in the Duplex. This auxiliary switch may VERSION
Momentary Cable Pull Limit Switches are be configured as 1NO - 1NC direct acting, The Smart Distributed System Output Ver-
offered with a black operating head and a 2NO - 2NC snap action (monitoring only) or sion provides Smart Distributed System
blue body. There is a choice of four different 1NO - 1NC with Smart Distributed System compatible switch status messaging. The
conduit openings: 1/2-14 NPT, 20mm, PF output (monitoring only).
1/2, and PG13.5. Duplex switches have 3
primary contact block (NC) must be wired to
the control current. The auxiliary contact
block has been replaced with the Smart
Distributed System circuitry.
Neon and LED indicators are available. A
standard conduit openings with two conduit
plugs provided.
6 watt incandescent pilot light is available
on the Duplex for high visibility at long
All switches come with a 1NO auxiliary con- distances.
tact as standard.
Snap action contact blocks and the Smart
Distributed Output Version should be used
for monitoring only. These types of switches
should not be used in control circuits.
A66
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
Limit and Enclosed Switches
CLS Series
Momentary Cable Pull Limit Switches: For Signaling Applications
SINGLE HEAD CLS ORDER GUIDE
CLS
–
BODY CODE
MODIFICATION CODES
A BLUE BODY – PG13.5
B BLUE BODY – 1/2 NPT
C BLUE BODY – 20MM
D BLUE BODY – PF1/2
1 HEAD ASSEMBLED WITH ACTUATOR TO THE LEFT
2 HEAD ASSEMBLED WITH ACTUATOR TO THE FRONT
3 HEAD ASSEMBLED WITH ACTUATOR TO THE
MOUNTING SURFACE
BASIC SWITCH CODE
3 1NO-1NC SNAP ACTION (Monitoring Only)
4 1NO-1NC DIRECT ACTING
HEAD CODES
B MOMENTARY
5 1NO-1NC DIRECT ACTING 240V NEON INDICATOR
6 1NO-1NC DIRECT ACTING 120V NEON INDICATOR
7 1NO-1NC DIRECT ACTING 24V LED INDICATOR
Notes:
ɀ Leave the MODIFICATION CODE blank if a modification is not required.
ɀ Standard head orientation is with actuator to the right.
ɀ Unit may be field modified.
EXAMPLE CATALOG LISTING
Catalog Listing
Description
CLSD4B-1
Single Head Cable Pull Limit Switch, Blue Body – PF 1/2, 1NO - 1NC
Direct Acting, Momentary, Head assembled with actuator to the left
DUPLEX HEAD 2CLS ORDER GUIDE
2CLS
–
BODY CODE
MODIFICATION CODES
(See chart below for numbered
modification codes.)
A BLUE BODY – PG13.5
B BLUE BODY – 1/2 NPT
C BLUE BODY – 20MM
D BLUE BODY – PF1/2
INDICATOR – PILOT LIGHT CODE
A 120V – 6W RED PILOT LIGHT
B 120V NEON INDICATOR
C 240V NEON INDICATOR
D 24V LED INDICATOR
PRIMARY BASIC SWITCH CODE – LEFT
1 1NO – 1NC DIRECT ACTING
OPERATING HEAD
B MOMENTARY, BOTH SIDES
AUXILIARY BASIC SWITCH CODE – RIGHT
1 1NO – 1NC DIRECT ACTING
3 2NO – 2NC (DPDT) SNAP ACTION (Monitoring Only)
4 1NO – 1NC WITH SDS OUTPUT (Monitoring Only)
9 NO SWITCH
Notes:
HEAD ORIENTATION
ɀ No numbered modification code indicates both heads oriented to side (Duplex Head).
ɀ Standard Conduit openings are left, center, and right with two conduit plugs furnished.
ɀ Leave the INDICATOR – PILOT LIGHT CODE blank if a pilot light is not required.
NUMBERED MOD CODES
MOD CODE LEFT HEAD RIGHT HEAD
ɀ Leave the HEAD ORIENTATION NUMBERED MODIFICATION CODE blank if not required. Do not enter zero.
1
2
3
4
5
6
7
8
FRONT
FRONT
FRONT
REAR
REAR
REAR
SIDE
FRONT
REAR
SIDE
EXAMPLE CATALOG LISTING
Catalog Listing
Description
FRONT
REAR
SIDE
2CLSB1B1-3
Duplex Head Cable Limit Switch, Blue Body – 1/2 NPT, 1NO – 1NC
Direct Acting, Momentary – Both Sides, 1NO – 1NC Direct Acting, No
Pilot Light, Left Head Front – Right Head Side
FRONT
REAR
SIDE
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
A67
Limit and Enclosed Switches
CLS Series
Momentary Cable Pull Limit Switches: For Signaling Applications
MOUNTING DIMENSIONS
(For reference only)
A68
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
Limit and Enclosed Switches
CLS Series
Momentary Cable Pull Limit Switches: For Signaling Applications
INSTALLATION HARDWARE
ɀ Aircraft cable precut to 25, 50, 100, 150
and 200 feet lengths
ɀ Lockout attachment
ɀ End springs for long cable spans to
compensate for temperature variations
ɀ Installation hardware kit supports cable
installations of 25 ft. and 50 ft.
INSTALLATION HARDWARE ORDER GUIDE
Catalog Listings
CLSZC1
Description
25 ft. Red Aircraft Cable, finished cable dia. 0.187 in
50 ft. Red Aircraft Cable, finished cable dia. 0.187 in
100 ft. Red Aircraft Cable, finished cable dia. 0.187 in
150 ft. Red Aircraft Cable, finished cable dia. 0.187 in
200 ft. Red Aircraft Cable, finished cable dia. 0.187 in
End Spring
CLSZC2
CLSZC3
CLSZC4
CLSZC5
CLSZ1S
CLSZ00
Installation Kit includes: 4 thimbles, 8 wire rope clamps, 1 turnbuckle (w/lock nuts), 9 eyebolts (w/hardware),
1 endspring, 1 conduit fitting
Notes:
1. Eyebolts should be spaced 1.8 to 2.4 m (6 to 8 ft.) apart.
2. One used for each 7.5 m (25 ft.) of cable span.
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada
A69
相关型号:
©2020 ICPDF网 联系我们和版权申明