3B15R [HONEYWELL]
Analog Circuit;型号: | 3B15R |
厂家: | Honeywell |
描述: | Analog Circuit |
文件: | 总4页 (文件大小:151K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
21-75-03-05
7/83
Thermocouples with
Protecting Tubes
Specification
Description
Straight Assemblies
These thermocouple assemblies include
an element which consists of thermo-
couple wires, double bore ceramic in-
sulators, terminal block, protecting tube
and terminal head. Constructed of high
quality materials to meet the high
Honeywell standards, these ther-
mocouples provide the solution to
temperature sensing problems in ap-
plications worldwide.
Mounting Attachments
Metal Tube
Terminal heads are available in two
types: screw cover (weatherproof)
shown in Figure 1 and general purpose.
Both types have 1/2-inch conduit con-
nection and the screw cover head is
also available with 3/4-inch connection.
Mounting bushings and adjustable
flanges are also available.
Reference
For complete data on the Honeywell
thermocouple line including ordering in-
formation, see Catalog 21-75-30-01
Ceramic Tube
Figure 1
TABLE 1 - Thermocouple Accuracies
Limits of Error (Select whichever is greater)
Temperature Range
Type of Wire
Premium Grade*
–––
Standard Grade
±1°C or ±1.5%
±1°C or ±0.75%
–200 to 0°C
0 to 350°C
Type T
±0.5°C or ±0.4%
±0.75° F or ±1%
±0.75°F or ±0.38%
±1.5°F or ±2%
±1.5°F or ± 0.75%
–300 to 32°F
32 to 700°F
±1.1°C or ±0.4%
±2°F or ±0.38%
±2.2°C or ±0.5%
±4°F or ±0.5%
Type J
Type E
Type K
0 to 750°C
32 to 1400°F
±1°C or ±0.4%
±2°F or ±0.38%
±1.7°C or ±0.5%
±3°F or ±0.5%
0 to 900°C
32 to 1600°F
±1.1°C or ±0.4%
±2.2°C or
±0.75%
±4°F or ±0.75%
0 to 1250°C
32 to 2300°F
0 to 1450°C
32 to 2700°F
±2°F or ±0.38%
–––
±1.5°C or
±0.25%
±3°C or ±0.25%
Type R or
Type S
–––
NOTE: When the limit of error is given in %, the percentage applies to the
temperature being measured, not the range.
*Available at additional cost.
Specification
21-75-03-05
TABLE 2 — Straight Assemblies (see Figure 1)
Model No.*
Protecting Tube Material
Calibration
Maximum Temperature
Protecting Tube O.D.
mm
inches
°F
°C
1D10B
Type T
Carbon Steel
316 S.S.
260
260
538
482
538
593
482
593
760
593
760
760
760
760
593
538
538
538
538
538
649
871
500
10.0
10.0
13.8
10.0
21.4
10.0
13.8
13.8
21.4
19.0
21.4
41.0
22.0
23.8
17.5
10.0
13.8
21.4
10.0
13.8
13.8
21.4
19.0
21.4
41.0
22.0
13.8
21.4
13.8
21.4
25.4
19.0
21.4
41.0
22.0
32.0
19.0
26.6
23.8
17.5
0.41
0.41
0.54
0.41
0.84
0.41
0.54
0.54
0.84
0.75
0.84
1.62
0.84
0.94
0.69
0.41
0.54
0.84
0.41
0.54
0.54
0.84
0.75
0.84
1.62
0.84
0.54
0.84
0.54
0.84
1.00
0.75
0.84
1.62
0.84
1.25
0.75
1.05
0.94
0.68
1D10T
500
3B10B
1000
900
Type J
Carbon Steel
Carbon Steel
Carbon Steel
316 S.S.
3D10B
3A10W
3D10T
1000
1100
900
3D10S
304 S.S.
304 S.S.
1100
1400
1100
1400
1400
1400
1400
1100
1000
1000
1000
1000
1000
1200
1600
1200
1600
1400
1600
1000
1000
1800
1800
1800
1800
2200
1400
1800
1800
1800
2000
2300
2000
3B10S
3A10PA
3B10P
Resisteat (446 S. S.)
Resisteat {446 S. S.)
Inconel
3A10M
3A10D
Cast Iron
3A10L
Nickel
3A15R
Sillramic
3B15R
Sillramic
Y(3)D10B
Y(3)B10B
Y(3)A10W
Y(3)D10T
Y(3)D10S
Y(3)B10S
Y(3)A10PA
Y(3)B10P
Y(3)A10M
Y(3)A10D
Y(3)A10L
5B10B
Carbon Steel
Carbon Steel
Carbon Steel
316 S.S.
Type E
304 S.S.
304 S.S.
Resisteat (446 S. S.)
Resisteat (446 S. S.)
Inconel
649
871
760
871
Cast Iron
Nickel
538
538
982
982
982
982
1204
760
982
982
982
1093
1260
1093
Type K
Carbon Steel
Carbon Steel
304 S.S.
5A10W
5B10S
5A10PA
5A10P
Resisteat (446 S. S.)
Resisteat (446 S. S.)
Resisteat (446 S. S.)
Inconel
5B10P
5A10M
5A10D
Cast Iron
5A10L
Nickel
5A10LA
5B10LA
5A10E
Nickel
Nickel
Cast T
5A15R
Sillramic
5B15R
Sillramic
Type R
Platinum
13% Rhodium
12.7
17.5
6G15N
6G15R
1260
1482
2300
2700
0.50
0.68
Quartz
Sillramic
Type S
Platinum
10% Rhodium
7G15N
7G15R
12.7
17.5
Quartz
1260
1482
2300
2700
0.50
0.68
Sillramic
*Follow with tube length and terminal head type.
Specification
21-75-03-05
Angle Assemblies
These assemblies have a protecting tube
of selected material, cast iron angle elbow
and carbon steel extension tube con-
necting the angle fitting to the terminal
head or with a full length protecting tube
with a 90° bend.
TABLE 3 — Assemblies with Angle Elbow
Calibration
Model No.*
Protecting Tube Material
Maximum Temperature
Protecting Tube O.D.
°C
°F
mm
inches
0.54
0.84
0.54
0.84
1.62
0.54
0.84
1.00
0.75
0.54
0.84
1.62
1.25
0.84
0.75
0.94
0.69
0.69
0.69
Type J
3B50B
3A50W
3B50S
3A50M
3A50D
5B50B
5A50PA
5A50P
5B50P
5B50S
5A50M
5A50D
5A50LA
5A50L
5B50LA
5A50R
5B50R
6G50R
7G50R
Carbon Steel
Carbon Steel
304 S.S.
538
538
593
760
760
538
982
982
982
982
1204
871
1000
1000
1100
1400
1400
1000
1800
1800
1800
1800
2200
1600
1800
1800
1800
2300
2000
2700
2700
13.8
21.4
13.8
21.4
41.2
13.8
21.4
25.4
19.0
13.8
21.4
41.2
32.0
22.2
19.0
23.8
17.5
17.5
17.5
Inconel
Cast Iron
Type K
Carbon Steel
Resisteat (446 S.S.)
Resisteat (446 S.S.)
Resisteat (446 S.S.)
304 S.S.
001-57
Inconel
Cast Iron
Nickel
982
982
982
1260
1093
1482
1482
Nickel
Nickel
Sillramic
Sillramic
Type R
Type S
Sillramic
Sillramic
Assemblies with 90° Bend
0.54
0.84
0.54
0.84
0.84
0.84
0.54
0.84
0.84
13.8
21.4
13.8
21.4
21.4
21.4
13.8
21.4
21.4
1000
1000
1100
1400
1400
1000
1800
1800
2200
538
538
593
760
760
538
982
982
1204
Carbon Steel
Carbon Steel
304 S.S.
3B56B
3A56W
3B56S
3A56PA
3A56M
5A56W
5B56S
5A56PA
5A56M
Type J
Resisteat (446 S.S.)
Inconel
Carbon Steel
304 S.S.
Type K
001-56
Resisteat (446 S.S.)
Inconel
*Follow with tube length, terminal head type and cold leg length.
Specification
21-75-03-05
Assemblies with Double Protecting
Tubes
These assemblies have two protecting
tubes to provide additional mechanical
protection for the thermocouple. The
primary (internal) tube is sillramic with the
outer tube of various materials as listed in
Table 4.
Metal
Ceramic
TABLE 4- Assemblies with Double Protecting Tubes
Maximum Temperature
Protecting Tube O.D.
Model No.*
Protecting Tuba Material
Calibration
inches
mm
°C
°F
1.25
0.84
1.75
2.00
3.00
1.25
0.84
1.75
2.00
3.00
32.0
21.4
44.4
50.8
76.2
32.0
21.4
44.4
50.8
76.2
Nickel
982
1800
2200
2700
2700
2700
1800
2200
2700
2700
2700
6G22E
6G22M
6G25H
6G25D
6G25D
Type R Platinum
13% Rhodium
1204
1482
1482
1482
982
1204
1482
1482
1482
Inconel
Silicon Carbide
Mullite
Mullite
Type S Platinum 7G22E
Nickel
Inconel
10% Rhodium
7G22M
7G25H
7G25D
7G25D
Silicon Carbide
Mullite
Mullite
Assemblies with Extension Pipe
Pipe extended assemblies are designed
for economical installations where a full
length protecting tube is not required. The
protecting tube and terminal head are
connected by a carbon steel extension
tube.
Metal
TABLE 5 — Pipe Extension Models
Protecting Tube Material
Maximum Temperature
Protecting Tube O.D.
Model No.*
Calibration
inches
0.54
1.00
0.75
0.84
0.69
0.54
1.00
0.75
0.84
1.05
0.84
1.25
0.75
0.69
0.69
0.69
mm
°C
°F
13.8
25.4
19.0
21.4
17.5
13.8
25.4
19.0
21.4
26.6
22.0
32.0
19
Type J
3B30S
3A30P
3B30P
3A30M
3B30R
5B30S
5A30P
5B30P
5A30M
5A30E
5A30L
5A30LA
5B30LA
5B30R
6G30R
7G30R
304 S.S.
593
760
593
760
593
982
982
982
1204
1093
982
982
982
1093
1482
1482
1100
1400
1100
1400
1100
1800
1800
1800
2200
2000
1800
1800
1800
2000
2700
2700
Resisteat (446 S.S.)
Resisteat (446 S.S.)
Inconel
Sillramic
304 S.S.
Resisteat (446 S.S.)
Resisteat (446 S.S.)
Inconel
Type K
Cast T
Nickel
Nickel
Nickel
Sillramic
Sillramic
Sillramic
17.5
17.5
17.5
Type R
Type S
*Follow with tube length, terminal head type and extension length.
Specifications are subject to change without notice.
For more information contact the nearest Honeywell sales office, or Honeywell Process Control Division, 1100 Virginia Drive,
Fort Washington, Pa. 19034. In Canada, Honeywell Limited, 155 Gordon Baker Road, Willowdale, Ontario M2H 3N7.
相关型号:
©2020 ICPDF网 联系我们和版权申明