77030 [HONEYWELL]

Set Points from 0.5 to 150 psi; 点集从0.5到150 psi
77030
型号: 77030
厂家: Honeywell    Honeywell
描述:

Set Points from 0.5 to 150 psi
点集从0.5到150 psi

文件: 总2页 (文件大小:127K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Set Points from 0.5 to 150 psi  
5000 Series Extended Duty Pressure Switch With Direct Action Blade Contacts  
The 5000 Series switch is specifically  
designed to stand up to extended duty  
applications. This switch is factory set  
Standard Specifications  
Type:  
Direct action  
blade contact  
Silver alloy,  
gold plated  
Factory set  
but capable of field adjustment. It  
features a Kapton diaphragm for  
compatibility with a wide variety of  
fluids, and various terminations  
including a Metri-Pack connector that  
forms a tight seal when connected.  
Among the outstanding design benefits  
are its durable construction, compact  
size, and enhanced set point integrity.  
Contacts:  
Set Point:  
from 0.5 to 150 PSI  
Operating Pressure:  
150 PSI for 0.5-24 PSI set point range,  
250 PSI for 25-150 PSI set point range  
Proof Pressure: 500 PSI  
Burst Pressure: 750 PSI for 0.5-24 PSI  
set point range  
Switch Boot P/N 79380  
for Vacuum and Pressure  
1250 PSI for 25-150 PSI  
set point range.  
Ratings:  
Resistive: 15 AMP-  
8 AMP-  
6
VDC  
12 VDC  
24 VDC  
4 AMP-  
2.9” REF.  
Inductive:  
1 AMP- 120 VAC  
0.5 AMP- 240 VAC  
Diaphragm: Polyimide film  
2.3” REF.  
Temperature  
Range:  
-40° F to + 250° F  
Connector: 1/8 -27 NPT male thread  
Terminals: #8-32 screws,  
1/4” blade,  
280 Series Metri-Pack  
Circuitry:  
SPST-N.O., N.C.,  
1 circuit adjustable dual  
circuit, or 2 circuits  
adjustable dual circuit.  
Also available are  
1.47” REF.  
1.47” REF.  
N.O./N.O. dual circuit  
5000 Series Switch  
with Metri-Pack Terminal  
5000 Series Switch  
with Screw Terminals  
and N.C./N.C. dual circuit.  
Plated Steel  
Base:  
Cover:  
Options:  
Glass reinforced polyester  
Brass, plastic or stainless  
steel base; various base  
connector thread sizes;  
wire leads (potted & sealed).  
NOTE: OPERATING MEDIA (PRESSURE SWITCH)  
The pressure switch is designed to operate with air,  
motor oils, transmission oils, jet fuels and other similar  
hydrocarbon media.  
4
5000 Series Pressure Switch With Standard Terminal  
Dual Circuit  
One circuit adjustable  
Dual Circuit  
Both circuits adjustable  
Single Circuit  
1 Terminal  
Single Circuit  
2 Terminals  
1
2
Part Number  
Screw Blade Screw Blade Screw  
78630 78631 78628 78629  
Part Number  
Contact  
Setting3  
Part Number  
Screw  
Contact  
Setting  
Factory  
Set At  
Part Number  
Circuitry  
Blade  
Blade  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
0.5-1 PSI  
±0.3  
1.1-3 PSI  
±0  
.5  
3.1-7 PSI  
±1  
8-13 PSI  
±2  
14-24 PSI  
±3  
25-50 PSI  
±5  
3-4 PSI  
±0.5  
5-8 PSI  
±1  
9-24 PSI  
±2  
25-50 PSI  
±3  
51-90 PSI  
+5/-2  
91-150 PSI  
+8/-2  
1 PSI  
2 PSI  
76081 76086  
76582 76590  
76082 76087  
76083 76088  
76084 76089  
76085 76090  
78711 78712  
76071 76076  
76579 76587  
76580 76588  
76072 76077  
76073 76078  
76074 76079  
76075 76080  
78634 78635 78632 78633  
78142 78399 76051 76056  
78149 78406 76061 76066  
78143 78400 76575 76583  
78150 78407 76577 76585  
78144 78401 76576 76584  
78151 78408 76578 76586  
78145 78402 76052 76057  
78152 78409 76062 76067  
78146 78403 76053 76058  
78153 78410 76063 76068  
78147 78404 76054 76059  
78154 78411 76064 76069  
78148 78405 76055 76060  
78155 78412 76065 76070  
4 PSI  
10 PSI  
15 PSI  
35 PSI  
60 PSI  
100 PSI  
51-90 PSI  
±7  
91-150PSI  
±10  
Notes:  
1. The N.C. circuit is the reference  
circuit for the dual circuit switch;  
the normally open circuit is not  
adjusted. The expected dead band  
between the N.C. & N.O. circuit  
is shown in the chart below. For  
applications requiring the normally  
open circuit as the reference circuit  
the N.C. circuit is not adjusted.  
5000 Series Pressure Switch With Metri-Pack Terminal  
Dual Circuit  
Both circuits adjustable  
(Mates with Packard  
P/N 12034147)  
Dual Circuit  
One circuit adjustable  
(Mates with Packard  
P/N 12034147)  
Single Circuit  
(Mates with Packard  
P/N 15300027)  
2
1
Contact  
Setting  
1-3 PSI  
±0.5  
4-6 PSI  
±1  
7-12 PSI  
±2  
13-24 PSI  
±3  
25-46 PSI  
±5  
47-76 PSI  
±6  
77-100 PSI  
±7  
Contact  
Setting3  
Part  
Number  
Factory  
Set At  
Part Number  
77038  
Circuitry  
Part Number  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
N.O.  
N.C.  
77029  
77020  
77030  
77021  
77031  
77022  
77032  
77023  
77033  
77024  
77034  
77025  
77035  
77026  
77036  
77027  
77037  
77028  
3-4 PSI  
±0.5  
5-10 PSI  
±1  
11-24 PSI  
±2  
25-46 PSI  
±3  
47-76 PSI  
+5/-2  
77-100 PSI  
+7/-2  
101-126 PSI  
+9/-2  
127-150 PSI  
+10/-2  
2 PSI  
77047  
2. Switch may be adjusted so that:  
A. N.C. circuit opens before N.O.  
circuit closes.  
B. N.C. and N.O. circuit have same  
set point.  
C. N.O. circuit closes before the  
N.C. circuit opens. (There is no  
dead band and both circuits are on  
for a brief period of time.)  
77039  
77040  
77041  
77042  
77043  
77044  
77045  
77046  
5 PSI  
77048  
77049  
77050  
77051  
77052  
77053  
77054  
10 PSI  
20 PSI  
35 PSI  
60 PSI  
85 PSI  
115 PSI  
135 PSI  
3. The tolerances given in the table  
are applicable to a switch adjusted  
so that the N.O. circuit closes  
before the N.C. circuit opens and  
applies to the N.C. circuit. The  
N.O. set point and tolerances are  
such that a minimum overlap of 1  
PSI exists during which both circuits  
are on.  
101-126  
±9  
127-150 PSI  
±10  
Note 1: Expected Dead Band (Higher than N.C. circuit)  
Contact  
Dead Band  
Setting  
0.5-3 PSI  
4-7 PSI  
1.5 PSI  
2.5 PSI  
3.5 PSI  
8 PSI  
15 PSI  
23 PSI  
40 PSI  
8-13 PSI  
14-24 PSI  
25-50 PSI  
51-90 PSI  
91-150 PSI  
5

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY