Flex Series  
GWF402 and  
GWF404  
2 and 4 Zone Conventional  
Fire Alarm Control Panels  
Description  
The Flex 402 is a two zone fire alarm control panel (FACP)  
and the Flex 404 is a four zone FACP. These control pan-  
els provide reliable fire signaling protection for small to  
medium sized retail, office, multi-family, or other similar  
c om me r ci al o r i n st i tu t i on al bu il d in g .  
Initiating device circuits (IDCs) for Flex Series panels are  
power limited and operate in Style B (Class B). Each panel  
is compatible with conventional input devices such as two-  
wire smoke detectors, four-wire smoke detectors, pull sta-  
tions, water flow devices, tamper switches and other nor-  
mally-open contact devices. This includes System Sensor  
GWF402 (left) and GWF404 (right)  
i3Series microprocessor-based detectors with advanced  
features like drift compensation, maintenance alert and  
freeze warning. (See Device Compatibility Document PN  
52195 for a listing of compatible devices.)  
Features  
Flex 402: Two Style B (Class B) IDC zones, one Style Y  
(Class B) NAC  
Outputs include one notification appliance circuit (NAC) on  
the Flex 402 and two NACs on the Flex 404. NACs are  
power limited and operate in Style Y (Class B). Each FACP  
has a Form-C Alarm and Trouble relay and 24 VDC special  
applications resettable power. In addition, the Flex 404 has  
a Form-C Supervisory relay and a special application non-  
resettable power output. The FACP supervises wiring, AC  
voltage and battery level.  
Flex 404: Four Style B (Class B) IDC zones, two Style Y  
(Class B) NACs  
Optional NAC Class A converter module (Flex 404)  
NAC synchronization and programmability features:  
- ADA compliant strobe synchronization  
- ANSI audible signals as required by NFPA 72  
- Silence inhibit, auto-silence, non-silenceable  
- Selective Silence: mute horns, keep strobes lit  
- Temporal or steady signal  
Silent or audible walk test from front keypad  
Zone disable, alarm verification selectable per zone  
Controls: Acknowledge, Alarm, Silence, Reset,  
Walktest, Zone enable/disable  
LED indicators: Alarm, Supervisory, Maintenance,  
Trouble (one per zone): AC, NAC / Zone disable, NAC  
fault, System / Power Trouble, Walktest, Alarm Silence,  
Charger / Battery / Earth Fault (on pcb)  
Alarm verification  
Activation of a compatible smoke detector or any normally-  
open fire alarm initiating device will activate audible and  
visual signaling devices, illuminate an indicating LED,  
sound the piezo sounder at the FACP, activate the FACP  
alarm relay and operate and optional modules used to  
notify a remote station or initiate an auxiliary control  
function.  
Both the Flex 402 and Flex 404 fire alarm control panels  
®
are listed to UL Standard 864, 9th Edition.  
Low AC voltage sense, automatic battery charger  
Piezo sounder for alarm, trouble, and supervisory  
An ISO 9000-2000 Company  
SIGNALING  
i 3™ is a trademark of Honeywell International Inc.  
MEA  
UL® is a registered trademark of Underwriter’s Laboratories Inc.  
Approved  
S521 366-04-E 7165-1288:180  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
©2007 by Honeywell International Inc. All rights reserved.  
Specifications are for information only, are not intended for installation pwurpwoswes,.ganadmareeswubejecllt-tofcchia.cngoemwithout notice. No responsibility is assumed by Gamewell-FCI for their use.  
9021-60292 Rev. A page 1 of 2  
Options  
Specifications (Continued)  
CAC-4  
Used to convert Style B (Class B) IDCs to  
Style D (Class A) and Style Y (Class B)  
NACs to Style Z (Class A). Mounts in  
FACP. Flex 404 only.  
Second 100VA transformer for maximum  
accessory power. Mounts in FACP. Flex  
404 only.  
Transmitter module provides output for  
local energy municipal box transmitter and  
alarm and trouble reverse polarity. Mounts  
in FACP. Flex 402 & Flex 404.  
Circuits (NAC) Operation: Style Y (Class B)  
Power limited circuitry  
Operating voltage: nominal 24 VDC  
Maximum signaling current: 2.5 A total  
(5.0 A Flex 404 with optional  
transformer)  
Maximum line impedance: 1.5 volt drop  
XRM-24  
4XTMF  
Form-C Relays Trouble, Alarm (Supervisory, Flex 404)  
Contact ratings 2 A @ 30 VAC  
(resistive)  
4XZMF  
4XLMF  
Zone relay module provides Form-C relays:  
Alarm Zones 1, 2, 3, 4, System Alarm,  
Trouble. Mounts in FACP. Flex 404 only.  
LED interface module supports the  
GWSAN-404 remote annunciator,  
supervises annunciator wiring for open  
conditions. Mounts in FACP. Flex 404 only.  
Four input/channel, dual line, digital alarm  
communicator/transmitter(DACT). Input/  
channels are compatible with normally  
open relay contacts, are supervised and  
fully programmable. Interfaces with public  
switched telephone networks and  
compatible with most central station receiv-  
ers. Flex 404 only.  
Resettable  
power  
Operating voltage: nominal 24 VDC  
Power limited circuitry  
Maximum available current: 500 mA  
Nonresettable Operating voltage: nominal 24 VDC  
power  
Power limited circuitry  
Maximum Available current: 500 mA  
411UD  
Cabinet  
Door: 15.3" x 14.7" x 0.3" (39 x 37 x 1 cm)  
Backbox: 15.0" x 14.5" x 3.0"  
(38 x 37 x 8 cm)  
Ordering Information  
GWF402  
Flex 402 conventional FACP, 2 zones,  
120 VAC, red  
GWSAN-404 Remote annunciator mounts in single-gang  
electrical box, provides LED indication of  
Alarm Zones 1, 2, 3, 4; and System  
GWF404  
Flex 404 conventional FACP, 4 zones,  
120 VAC, red  
EOL resistor, 4.7K ohm, ½ watt  
Flex 402 and Flex 404 Installation &  
Operation Manual  
71252  
52194  
Trouble. Flex 404 only.  
Specifications  
Options:  
CAC-4  
Class A converter for initiating device  
circuits and notification appliance cir-  
cuits (cannot be used on Flex 402)  
Transformer, expands NAC circuit  
power from 3 to 5 amps  
Transmitter module for remote station  
output or municipal box connection  
Relay module, four relays-by-zone,  
alarm and trouble contacts, 24VDC  
Remote annunciator driver, 24 VDC,  
supports GWSAN-404  
Four channel dual slave programmer  
DACT, Form C relay and upload/down-  
load capability; with enclosure, requires  
PRO-411  
Programmer, use with 411UD,  
411UDAC  
AC Power  
120 VAC, 50/60Hz, 2.3 A  
Battery  
Max. charging circuit: 27.6 VDC@ 0.8A  
Max. charger capacity: 18 Ah (two 7Ah  
batteries fit inside FACP)  
XRM-24  
4XTMF  
4XZMF  
4XLMF  
411UD  
Initiating Device Alarm zones 1 & 2 (Flex 402 / Flex 404)  
Circuits (IDC)  
Alarm zones 3 & 4 (Flex 404 only)  
Operation: All zones Style B (Class B)  
Power limited circuitry  
Operating voltage: nominal 20 VDC  
Alarm current: 15 mA minimum  
Short circuit current: 40 mA maximum  
Standby current: 4 mA  
PRO-411  
GWSAN-404  
BB-17F  
Maximum loop resistance: 100 ohms  
LEDremoteannunciatorforFlex404,  
4 alarms, 1 trouble (requires 4XLMF)  
Battery box, houses 2 batteries  
(7-18 Ah max)  
Notification  
One NAC: Flex 402; two NACs:Flex 404  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
9021-60292 Rev. A page 2 of 2  
www.gamewell-fci.com  

相关型号:

BB-183-10

Wire Terminal, 2mm2,
MOLEX

BB-183-10T

Wire Terminal, 2mm2,
MOLEX

BB-2

Dual action fire alarm station
GAMEWELL-FCI

BB-200.000MBE-T

OSC XO 200.000MHZ LVPECL SMD
ETC

BB-201-76HDX

Wire Terminal
MOLEX

BB-201-76HDXT

Wire Terminal
MOLEX

BB-207-04X

Wire Terminal, 2mm2,
MOLEX

BB-207-04XT

Wire Terminal, 2mm2,
MOLEX

BB-207-06X

InsulKrimp™ Spade Tongue Terminal for 14-16 AWG Wire
MOLEX

BB-207-06XT

Wire Terminal, 2mm2,
MOLEX

BB-213-04X

Wire Terminal, 2mm2,
MOLEX

BB-213-04XT

Wire Terminal, 2mm2,
MOLEX