EXD-Q26-2 [HONEYWELL]

Snap Acting/Limit Switch, DPDT, Momentary, 0.3A, 125VDC, 5.3mm, Wire Terminal, Panel Mount-threaded;
EXD-Q26-2
型号: EXD-Q26-2
厂家: Honeywell    Honeywell
描述:

Snap Acting/Limit Switch, DPDT, Momentary, 0.3A, 125VDC, 5.3mm, Wire Terminal, Panel Mount-threaded

开关 瞄准线 光电二极管
文件: 总13页 (文件大小:842K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MICRO SWITCH™  
Hazardous Location Switches  
EX Series  
Datasheet  
MICRO SWITCH™ EX Series  
Hazardous Location Limit Switches  
MICRO SWITCH™ EX Series switches feature the smallest UL-listed housings available for use in hazardous locations. The EX  
Series switch cavity is designed to cool expanding gases below the ignition temperature of the surrounding explosive atmosphere.  
The EX Series is capable of switching up to 20 amps while providing ample wiring space for ease of installation. Single and double  
conduit openings are available. Dual conduit openings may allow for through wiring of multiple switches. The EX Series can be  
mounted from any of the switchs four sides.  
What makes our switches better?  
Honeywell has over 80 years of switch manufacturing experience  
covering most environment types  
Proven technology plus superior quality and service are offered  
world-wide. The EX Series holds multiple agency approvals,  
including CE, IEC Ex, UL, CSA, and ATEX directives  
Multiple actuator options make the EX Series a good choice for  
indoor explosion-proof applications  
Smallest UL-listed, power-load carrying switch available for use in  
hazardous locations  
Manufactured for hars
and explosive environ
RELIABILITY • ACTUATION VARIETY  
sensing.honeywell.com  
2
COMPACT AND RUGGED HOUSING  
Features  
and Benefits  
Often used in applications where space is at a premium, MICRO SWITCH™ EX  
Series switches feature ample wiring space that eases installation time. The  
four-sided mounting with optional mounting bracket simplifies installation in most  
applications. The EX Series offers dual conduit openings on select models that  
allow for through wiring making it easier to wire multiple switches in a single circuit.  
International approvals for use around the world  
WIDE VARIETY OF PRODUCT OFFERINGS AND VARIATIONS  
Broad range of actuator styles available in pin plunger and rotary configurations.  
Switching capacity from 1 A for low energy loads, up to 20 A for most industrial  
electrical loads.  
DESIGN FLEXIBILITY  
Rotary actuators are field adjustable for quick set up and application adaptability.  
Roller lever actuators are adjustable through 360° of rotation. 1EX and 2EX listings  
have dual conduit openings enabling “wire through” or allowing the user to  
split the wiring of a double pole switch with one pole exiting each side.  
Potential Applications  
INDUSTRIAL PAINT BOOTHS  
Position detecting in automated paint booths used by indoor industrial painting  
companies  
Automotive paint booth door position detection assures the door is closed before  
paint can be applied  
PETROLEUM AND CHEMICAL PLANTS  
Valve position in indoor potentially explosive environments in petroleum refineries  
and chemical plants  
PROCESSING FACILITIES  
Position sensing indoors at grain handling and processing plants, pulp and paper  
processing, lumber and other types of facilities where dust and other fine particles  
in the atmosphere may create the potential for explosions  
sensing.honeywell.com  
3
EX Series  
Table 1. Specifications  
Characteristic  
Parameter  
Product type  
MICRO SWITCH™ hazardous location limit switches  
overtravel top plunger  
adjustable roller lever  
side roller lever  
rod lever  
one-way roller lever  
manually activated paddle  
Actuators  
adjustable rod lever with one-inch nylon roller  
Circuitry  
SPDT, DPDT  
Electrical  
1 A, 3 A, 5 A, 10 A, 15 A, and 20 A  
Aluminum die-cast  
Housing material  
Termination types  
1/2-14 NPT conduit, preleaded  
NEMA 1, 7, and 9, UL listed, and CSA certified:  
Class I, Div.1 & 2, Groups B*, C, and D  
[*Group B - only as noted in order guide]  
Class II, Div.1 & 2, Groups E, F, and G  
Sealing  
-40 °C to 71 °C [-40 °F to 160 °F]  
*High temp models available up to 204 °C [400 °F] (refer to order guide on pages 6 and 7)  
Operating temperature1  
Agency approvals and standards  
UL listed  
IEC Ex, ATEX (CE), UL, CSA  
#E14274  
CSA certified  
#LR57324  
ATEX directive2  
KEMA 04ATEX2312X  
KEM 08.0012X  
IEC Ex certified  
UNSPSC code  
302119  
UNSPSC commodity  
302119 Switches and controls and relays  
1 Refer to order guide  
2 Most models, refer to individual specifications for selected catalog listings  
Table 2. Agency Approvals and Standards  
UL, CE/ATEX, CSA, IEC Ex, INMETRO  
Standards & Designations  
UL listed  
#E14274  
UL 1203  
CSA certified  
#LR57324  
C22.2 No. 25 and No. 30  
II 2 G Ex d IIB + H2 T6 Gb (EX)  
II 2 G Ex d IIB + H2 T2 Gb (EXHT)  
EN60079-0 and EN60079-1  
ATEX directive *  
KEMA 04ATEX2312X  
II 2 G Ex d IIB + H2 T6 Gb (EX)  
II 2 G Ex d IIB + H2 T2 Gb (EXHT)  
IEC60079-0 and IEC60079-1  
IEC Ex certified *  
KEM 08.0027X  
In process  
INMETRO certified *  
IEC60079-0 and IEC60079-1  
*Most models, refer to individual specifications for selected catalog listings  
sensing.honeywell.com  
4
MICRO SWITCH™ Hazardous Location Limit Switches  
Table 3. Circuitry and Electrical Ratings  
Rating  
Table 4. Hazardous Location Classifications  
Rating  
Circuitry  
Electrical rating  
Classification  
code  
code  
UL/CSA Rating:  
Explosion Proof-UL listed for Hazardous Locations  
15 A, 125, 250, or 480 Vac  
1/8 HP, 125 Vac; 1/4 HP, 250 Vac  
0.5 A, 125 Vdc; 0.25 A 250 Vdc  
1
2
NEMA 7, Class I, Groups B, C, and D  
NEMA 9, Class II, Groups E, F, and G  
A
SPDT  
Explosion Proof-UL listed for Hazardous Locations  
NEMA 7, Class I, Groups C and D  
UL/CSA Rating:  
20 A, 125, 250, or 480 Vac  
10 A, 125 Vac “L”  
NEMA 9, Class II, Groups E, F, and G  
B
C
SPDT  
DPDT  
European Hazardous Locations Designation:  
Ex dIIB + H2 T6 Category II 2 G  
3
4
1 HP, 125 Vac; 2 HP, 250 Vac  
0.5 A, 125 Vdc; 0.25 A, 250 Vdc  
European Hazardous Locations Designation:  
Ex dIIB + H2 T2 Category II 2 G  
UL/CSA Rating:  
10 A, 125 or 250 Vac  
0.3 A, 125 Vac; 0.15 A 250 Vdc  
Series  
Code  
ATEX Temperature Rating  
UL/CSA Rating:  
D
E
F
SPDT  
SPDT  
SPDT  
10 A, 125, 250, or 480 Vac  
0.5 A, 125 Vdc; 0.25 A 250 Vdc  
EX  
T6  
T2  
-40 °C to 70 °C [-40 °F to 158 °F]  
-40 °C to 204 °C [-40 °F to 400 °F]  
EXHT  
UL Rating: 1 A, 125 Vac  
UL/CSA Rating:  
3 A, 125 or 250 Vac  
1/10 HP, 125 Vac; 1/6 HP, 250 Vac  
UL/CSA Rating:  
G
SPDT  
5 A, 125, 250, or 480 Vac;  
0.50 A, 125 Vdc; 0.25 A, 250 Vac  
sensing.honeywell.com  
5
EX Series  
MICRO SWITCH™ EX SERIES ORDER GUIDE  
5,56  
[0.219]  
(8°)  
0,18  
[0.007]  
(0.25°)  
15 A  
(A)  
2,22 N to 5,56 N  
[8 oz to 20 oz]  
EX-AR  
CW*  
CW*  
SPDT  
SPDT  
2, 3  
2, 3  
90°  
90°  
5,56  
[0.219]  
(8°)  
0,18  
15 A  
(A)  
2,22 N to 5,56 N  
[8 oz to 20 oz]  
EX-AR141  
[0.007] No mounting bracket  
(0.25°)  
5,56  
[0.219]  
(8°)  
20 A  
(B)  
3,34 N to 8,90 N  
[12 oz to 32 oz]  
0,304  
[0.012]  
EXA-AR  
EXA-AR20  
EX-AR16  
CW*  
CW*  
SPDT  
SPDT  
SPDT  
2, 3  
2, 3  
2, 3  
25°  
25°  
90°  
5,56  
[0.219]  
(8°)  
15 A  
(B)  
No lever furnished  
(order separately)  
5,56  
[0.219]  
(8°)  
0,18  
Low O.F.  
CW or  
CCW*  
15 A  
(A)  
0,56 N [2 oz]  
max.  
[0.007] (no return spring) with-  
(0.25°)  
out mounting bracket  
0.125 in x 5.28 in  
aluminum lever (no  
mounting bracket)  
EX-  
AR1613  
15 A  
(A)  
0,56 N [2 oz]  
max.  
CW*  
CW*  
SPDT  
SPDT  
2, 3  
2, 3  
16° 2° 40° min.  
3,81 N to 9,53 N  
[12.5 oz to  
5,56  
0,18  
[0.007]  
(0.25°)  
15 A  
(A)  
No lever furnished  
(order separately)  
EX-AR20  
[0.219]  
(8°)  
90°  
31.25 oz]  
0,18  
[0.007]  
(0.25°)  
15 A  
(A)  
0,45 Nm  
[4.0 in-lb]  
1,65  
[0.065]  
No lever furnished  
(order separately)  
EX-AR230  
CCW*  
CW*  
SPDT  
SPDT  
2, 3  
2, 3  
25°  
90°  
5,56  
[0.219]  
(8°)  
0,533  
[0.021]  
(0.75°)  
EX-  
AR471-3  
15 A  
(A)  
3,34 N to 7,32 N  
[12 oz to 24 oz]  
36 inch leadwire  
Manual  
opera-  
tion  
3,18  
[0.125]  
min.  
0,077  
[0.003]  
approx.  
15 A  
(A)  
Large 3 in x 3.5 in  
paddle  
EX-AR50  
SPDT  
2, 3  
11,12 N [40 oz]  
*Note: CW (Clockwise) and CCW (Counter-Clockwise) when looking at nameplate. EX Series switches are not sealed against liquids and are not  
intended to be used in liquid splash environments or outdoor use without protection. NEMA 1, 7, 9 only.  
sensing.honeywell.com  
6
MICRO SWITCH™ Hazardous Location Limit Switches  
MICRO SWITCH™ EX SERIES ORDER GUIDE, CONTINUED  
5,56  
[0.219]  
(8°)  
0,18  
[0.007]  
(0.25°)  
15 A  
(A)  
2,22 N to 5,56 N  
[8 oz to 20 oz]  
EX-AR128  
EXD-AR-3  
CW*  
CW*  
SPDT  
DPDT  
2, 3  
1, 3  
90°  
25°  
One-way roller lever  
36 inch wire leads  
10 A  
(C)  
2,44 N to 7,32 N  
[8 oz to 24 oz]  
6,35  
[0.25]  
2,77  
[0.109]  
3,18  
[0.125]  
min.  
20 A  
(B)  
2,77  
[0.109]  
0,229  
[0.009]  
EXA-N  
EXA-Q  
Plunger SPDT  
2, 3  
2, 3  
15,57 N [56 oz]  
With seal boot  
3,18  
[0.125]  
min.  
20 A  
(B)  
1,27  
[0.05]  
0,229  
[0.009]  
Plunger SPDT  
Plunger SPDT  
Plunger SPDT  
8,90 N [32 oz]  
8,90 N [32 oz]  
13,34 N [48 oz]  
3,18  
[0.125]  
min.  
3 A  
(F)  
1,27  
[0.05]  
0,229  
[0.009]  
EXHT-Q  
EX-Q400  
EXHT-AR  
1, 4  
400° high temperature  
5 A  
(G)  
1,98  
[0.078]  
4,78  
[0.188]  
0,102  
[0.004]  
400° high temperature  
intermittent exposure  
1
5,56  
[0.219]  
(8°)  
3 A  
(F)  
3,34 N to 8,90 N  
[12 oz to 32 oz]  
0,406  
[0.016]  
CW*  
SPDT  
1, 4  
25°  
400° high temperature  
5,56  
[0.219]  
(8°)  
0,18  
[0.007]  
(0.25°)  
15 A  
(A)  
2,22 N to 5,56 N  
[8 oz to 20 oz]  
1EX1  
2EX1  
CW*  
CW*  
SPDT  
DPDT  
2, 3  
2, 3  
90°  
25°  
Dual conduit openings  
Dual conduit openings  
5,56  
[0.219]  
(8°)  
0,305  
[0.012]  
(0.5°)  
20 A  
(B)  
3,34 N to 8,90 N  
[12 oz to 32 oz]  
*Note: CW (Clockwise) and CCW (Counter-Clockwise) when looking at nameplate. EX Series switches are not sealed against liquids and are not  
intended to be used in liquid splash environments or outdoor use without protection. NEMA 1, 7, 9 only.  
sensing.honeywell.com  
7
EX Series  
DIMENSIONAL DRAWINGS mm [in]  
Figure 1. MICRO SWITCH™ EX Series, no lever  
Figure 5. MICRO SWITCH™ EX Series, rod lever  
Figure 2. MICRO SWITCH™ EX Series, side rotary  
Figure 6. MICRO SWITCH™ EX Series, top pin plunger  
Figure 3. MICRO SWITCH™ EX Series, side rotary with two  
conduit openings  
Figure 7. MICRO SWITCH™ EX Series, boot sealed  
Figure 8. MICRO SWITCH™ EX Series, manually actuated  
Figure 4. MICRO SWITCH™ EX Series, one-way lever  
sensing.honeywell.com  
8
MICRO SWITCH™ Hazardous Location Limit Switches  
Table 5. Replacement Catalog Listings  
EX Series Part Number  
Internal Switching Element/  
Basic Switch  
Actuator  
Internal Springs  
EXA-AR  
EXA-Q  
BA-2R-P4  
BZ-2R-P4  
BZ-2R-P4  
BZ-2R-P4  
BZ-2RW88-P5  
BZ-2RW88-P5  
BZ-2R-P4  
BZ-2R-P4  
BZ-2R-P4  
BZ-2R-P4  
DT-2R4-A7  
DT-2R711-A7  
DT-2R-A7  
6PA5-EX  
8PA15-EX  
6PA5-EX  
6PA130-EX  
6PA5-EX  
6PA136-EX  
*
33PA6-EX  
EX-AR  
33PA7-EX  
33PA7-EX  
EX- AR128  
EX-AR16  
EX-AR1613  
EX-AR20*  
EX-AR30  
EX-AR50  
EX-AR800  
EXD-AR-3  
EXD-AR30-3  
EXD-Q-3  
EXH-AR3  
EXH-AR33  
EX-N15  
33PA7-EX  
33PA5-EX  
33PA7-EX  
33PA7-EX  
33PA6-EX  
33PA5-EX  
6PA5-EX  
6PA134-OP  
6PA5-EX  
6PA5-EX  
6PA5-EX  
8PA77-EX  
6PA5-EX  
6PA5-EX  
8PA12-EX  
8PA15-EX  
8PA15-EX  
4HS202  
33PA6-EX  
33PA6-EX  
4HS203  
BZ-2R15-P4  
BZ-2R-P4  
BZ-2R-P4  
EX-Q  
EX-Q800  
Double Conduit  
1EX1  
BZ-2R-P4  
BZ-2R-P4  
DT-2R4-A7  
6PA5-EX  
6PA5-EX  
6PA5-EX  
33PA6-EX  
33PA6-EX  
33PA6-EX  
2EX1  
4EX1-3  
* Order levers separately  
GROUNDING SCREW ASSEMBLY  
(for equipped models only)  
Table 6. Actuator Order Codes  
Type  
Part Number  
One-way roller lever  
(for CW actuation)  
6PA130-EX  
(bronze roller)  
Pan-head Phillips screw  
with external lock washer  
Metal clamp  
One-way roller lever  
(for CCW actuation)  
6PA142-EX  
(bronze roller)  
Adapter screw  
Adjustable length  
roller lever  
43 mm to 76 mm  
[1.7 in to 3 in]  
6PA138-EX  
(nylon roller)  
Washer  
Rod lever  
6PA136-EX  
134 mm [5.28 in]  
(aluminum rod)  
Adjustable length  
317,5 mm [12.5 in]  
max. rod lever  
6PA204-EX  
with 25,4 mm [1 in]  
nylon roller  
6PA5-EX  
(bronze roller)  
6PA127-EX  
(nylon roller)  
Roller lever  
sensing.honeywell.com  
9
EX Series  
Table 7. Mounting Brackets  
15PA85-EX (for side rotary)  
15PA86-EX (for top plunger)  
used for top, bottom, back, or end mounting. It is furnished with each  
switch, except where noted in the order guides.  
ordered separately for top mounting of plunger switches. EX switches  
may also be direct mounted, using 10-32 UNF screws.  
This datasheet supports the following MICRO SWITCH™ EX Series Hazardous Location Limit Switches  
1EX1  
2EX1  
EX-AR1613  
EX-AR1620  
EX-AR-1621  
EX-AR182  
EX-AR20  
EX-AR800  
EX-AR830  
EX-AR87  
EXD-AR20-3  
EXD-AR-3  
EXD-AR30-3  
EXD-AR30-6  
EXD-AR62-3  
EXD-AR87-3  
EXD-N-3  
EXH-AR3  
EXH-AR33  
EXH-AR7  
EXH-AR7-R1  
EXH-N  
EXH-Q26-2  
EXHT-AR  
EXHT-AR403  
EXHT-Q  
EX-N15  
EX-N152  
EX-Q  
EX-Q1  
EX-Q171  
EX-Q173  
EX-Q19  
EX-Q22  
EX-Q400  
EX-Q62  
EX-Q800  
15PA85-EX  
19PA4-EX  
33PA1-EX  
33PA5-EX  
33PA6-EX  
33PA7-EX  
6PA126-EX  
6PA127-EX  
6PA130-EX  
6PA136-EX  
6PA138-EX  
6PA142-EX  
6PA204-EX  
6PA5-EX  
8PA12-EX  
8PA15-EX  
8PA77-EX  
EX-XR3  
4EX1-3  
4EX5-3  
EXA-AR  
EXA-AR20  
EXA-AR62  
EXA-N  
EXA-Q  
EX-AR  
EX-AR128  
EXAR-141  
EX-AR16  
EX-AR230  
EX-AR30  
EX-AR400  
EX-AR420  
EX-AR471-15  
EX-AR471-3  
EX-AR50  
EXD-Q26-2  
EXD-Q-3  
EXD-Q62-3  
EXH-AR2  
EX-XR9  
EX-YQ-3  
EX-AR68  
EX-AR8  
sensing.honeywell.com  
10  
MICRO SWITCH™ Hazardous Location Limit Switches  
Table 8. Additional Available EX Lstings  
Class 1  
Group  
B
2-CKT  
DB  
Pre-  
leaded  
Listing  
CW  
CCW  
Plunger  
SPDT  
DPDT  
1 A  
10 A  
15 A  
20 A  
EXA-AR62  
EXA-N  
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
EX-AR1620  
EX-AR-1621  
EX-AR182  
EX-AR30  
ü
ü
ü
ü
ü
ü
EX-AR400  
EX-AR420  
EX-AR471-15  
EX-AR471-3  
EX-AR68  
5 A  
5 A  
ü
ü
ü
ü
ü
ü
ü
15 ft  
3 ft  
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
EX-AR8  
EX-AR800  
EX-AR830  
EX-AR87  
ü
ü
ü
ü
ü
EXD-AR20-3  
EXD-AR-3  
EXD-AR30-3  
EXD-AR30-6  
EXD-AR62-3  
EXD-AR87-3  
EXD-N-3  
3 ft  
3 ft  
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
3 ft  
ü
ü
6 ft  
3 ft  
ü
ü
3 ft  
3 ft  
ü
ü
ü
ü
EXD-Q26-2  
EXD-Q-3  
3 ft  
2 ft  
EXD-Q62-3  
EXH-AR2  
EXH-AR3  
EXH-AR33  
EXH-AR7  
EXH-AR7-R1  
EXH-N  
3 ft  
ü
ü
ü
ü
ü
ü
ü
10.5 ft  
10.5 ft  
3 ft  
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
EXH-Q26-2  
EXHT-AR403  
EX-N15  
ü
ü
3 A  
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
EX-N152  
SPNO  
ü
EX-Q  
ü
EX-Q1  
SPNO  
ü
ü
EX-Q171  
EX-Q173  
ü
EX-Q19  
ü
EX-Q22  
ü
EX-Q62  
ü
EX-Q800  
ü
ü
ü
Double Conduit  
4EX1-3  
3 ft  
3 ft  
ü
ü
ü
ü
ü
ü
4EX5-3  
sensing.honeywell.com  
11  
EX Series  
ADDITIONAL INFORMATION  
WARNING  
PERSONAL INJURY  
The following associated literature is available on the Honeywell web  
site at sensing.honeywell.com:  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the product  
could result in personal injury.  
• Product installation instructions  
• Product range guide  
• Hazardous location switches product brochure  
• Product application-specific information  
Failure to comply with these instructions could result in  
death or serious injury.  
– Applicaiton note: Electronic sensors and electromechanical  
switches in valves and flow meters  
WARNING  
MISUSE OF DOCUMENTATION  
– Application note: Industrial waste water treatment  
– Application note: Sensors and switches for industrial manual  
process valves  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
– Sensors and switches in oil rig applications  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywells standard  
product warranty applies unless agreed to otherwise by Honeywell  
in writing; please refer to your order acknowledgement or consult  
your local sales office for specific warranty details. If warranted  
goods are returned to Honeywell during the period of coverage,  
Honeywell will repair or replace, at its option, without charge those  
items it finds defective. The foregoing is buyer’s sole remedy  
and is in lieu of all other warranties, expressed or implied,  
including those of merchantability and fitness for a particu-  
lar purpose. In no event shall Honeywell be liable for conse-  
quential, special, or indirect damages.  
While we provide application assistance personally, through our  
literature and the Honeywell website, it is up to the customer to  
determine the suitability of the product in the application.  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this printing.  
However, we assume no responsibility for its use.  
sensing.honeywell.com  
12  
Find out more  
Honeywell serves its customers  
through a worldwide network  
of sales offices, representatives  
and distributors. For application  
assistance, current specifications,  
pricing or name of the nearest  
Authorized Distributor, contact  
your local sales office.  
To learn more about Honeywells  
sensing and control products,  
call +1-815-235-6847 or  
1-800-537-6945,  
visit sensing.honeywell.com, or  
e-mail inquiries to  
info.sc@honeywell.com  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
Golden Valley, MN 55422  
honeywell.com  
002390-1-EN IL50 GLO  
November 2014  
Copyright © 2014 Honeywell International Inc. All rights reserved.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY