HIH-3602-L [HONEYWELL]

Analog Circuit, 1 Func, MBCY6, TO-39, 6 PIN;
HIH-3602-L
型号: HIH-3602-L
厂家: Honeywell    Honeywell
描述:

Analog Circuit, 1 Func, MBCY6, TO-39, 6 PIN

文件: 总3页 (文件大小:301K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Interactive Catalog Replaces Catalog Pages  
Honeywell Sensing and Control has replaced  
the PDF product catalog with the new  
Interactive Catalog. The Interactive Catalog is  
a power search tool that makes it easier to find  
product information. It includes more  
installation, application, and technical  
Click this icon to try the new  
information than ever before.  
Interactive Catalog.  
Sensing and Control  
Honeywell Inc.  
11 West Spring Street  
Freeport, Illinois 61032  
Humidity Sensors  
HIH Series  
Relative Humidity  
FEATURES  
GENERAL INFORMATION  
ɀ Linear voltage output vs %RH  
ɀ Laser trimmed interchangeability  
ɀ High accuracy  
The HIH-3602-L IC (Integrated Circuit)  
Relative Humidity (RH) sensor delivers  
instrumentation quality RH sensing per-  
formance in a rugged, low cost, slotted  
TO-39 housing.  
ɀ Fast response  
ɀ Stable, low drift performance  
ɀ Chemically resistant  
ɀ Built-in static protection  
The RH sensor is a thermoset polymer  
capacitive sensing element with on-chip  
integrated signal conditioning. On-board  
signal conditioning reduces product de-  
velopment times while a typical current  
draw of only 200 ȖA makes the  
HIH-3602-L perfect for battery powered  
systems.  
TYPICAL APPLICATIONS  
ɀ Refrigeration  
ɀ Drying  
ɀ Meteorology  
ɀ Battery-powered systems  
ɀ OEM assemblies  
ORDER GUIDE  
NIST CALIBRATION  
HIH-3602-L may be ordered with a NIST calibration and sensor  
specific data printout. Append ‘‘CP’’ to the model number to  
order.  
Catalog Listing  
HIH-3602-L  
Description  
Integrated circuit humidity sensor in TO-39 can  
HIH-3602-L-CP  
Integrated circuit humidity sensor in TO-39 can  
with calibration and data printout  
RH SENSOR CONSTRUCTION  
Sensor construction consists of a planar capacitor with a sec-  
ond polymer layer to protect against dirt, dust, oils and other  
hazards.  
MOUNTING DIMENSIONS (for reference only)  
CAUTION  
PRODUCT DAMAGE  
Theinherentdesignofthiscomponentcausesittobesensitive  
to electrostatic discharge (ESD). To prevent ESD-induced  
damage and/or degradation, take normal ESD precautions  
when handling this product.  
INTERNAL PIN CONNECTIONS  
0.018 (0,46) dia. lead gold plated (6 places)  
A, B  
C
No connection  
+VDC supply  
() Power or ground  
VDC out  
D
E
F
Case ground  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  
97  
Humidity Sensors  
HIH Series  
Relative Humidity  
PERFORMANCE SPECIFICATIONS  
Parameter  
Conditions  
(1)  
RH Accuracy  
±2% RH, 0-100% RH non-condensing, 25°C, Vsupply 5 VDC  
±5% RH, 0-60% RH; ±8% @ 90% RH typical  
±0.5% RH typical  
RH Interchangeability  
RH Linearity  
RH Hysteresis  
±1.2% of RH span maximum  
±0.5% RH  
RH Repeatability  
RH Response Time, 1/e  
RH Stability  
30 seconds in slowly moving air at 25°C  
±1% RH typical at 50% RH in 5 years  
Power Requirements  
Voltage Supply  
Current Supply  
4 to 5.8 VDC, sensor calibrated at 5 VDC  
200 ȖA at 5 VDC  
Voltage Output  
Vout Vsupply (0.0062 (Sensor RH) +0.16), typical @ 25°C  
(Data printout provides a similar, but sensor specific, equation at 25°C.)  
0.8 to 3.9 VDC output @ 25°C typical  
Push/pull symmetric; 50 ȖA typical, 20 ȖA minimum, 100 ȖA maximum  
Turn-on 0.1 second  
V
supply 5 VDC  
Drive Limits  
Temp. Compensation  
True RH (Sensor RH)/(1.093-.0012T), T in °F  
True RH (Sensor RH)/(1.0546-0.00216T), T in °C  
±0.007% RH/°C (negligible)  
Effect @ 0% RH  
Effect @ 100% RH  
0.22% RH/°C (<1% RH effect typical in occupied space systems above 15°C (59°F))  
Humidity Range  
Operating  
Storage  
0 to 100% RH, non-condensing  
(1)  
0 to 90% RH, non-condensing  
Temperature Range  
Operating  
Storage  
40°C to 85°C (40°F to 185°F)  
40°C to 125°C (40°F to 257°F)  
(2)  
Package  
Handling  
Six pin TO-39 with slotted nickel cap  
Static sensitive, diode protected to 15 kV maximum  
Notes:  
1. Extended exposure to 90% RH causes a reversible shift of 3% RH.  
2. This sensor is light sensitive. For best results, shield the sensor from bright light.  
OUTPUT VOLTAGE VS RELATIVE HUMIDITY (at 0°C)  
OUTPUT VOLTAGE VS RELATIVE HUMIDITY  
(at 0°C, 25°C, and 85°C)  
98  
Honeywell ɀ Sensing and Control ɀ1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ1-800-737-3360 Canada  

相关型号:

HIH-3605-B

Analog Circuit, 1 Func, 0.050 INCH PITCH, SIP-3
HONEYWELL

HIH-3610-001

Molded thermoset plastic housing with cover
HONEYWELL

HIH-3610-002

Molded thermoset plastic housing with cover
HONEYWELL

HIH-3610-003

Molded thermoset plastic housing with cover
HONEYWELL

HIH-3610-004

Molded thermoset plastic housing with cover
HONEYWELL

HIH-4000

Humidity Sensors
HONEYWELL

HIH-4000-001

Integrated Circuity Humidity Sensor
HONEYWELL

HIH-4000-002

Integrated Circuity Humidity Sensor
HONEYWELL

HIH-4000-003

Integrated Circuity Humidity Sensor
HONEYWELL

HIH-4000-004

Integrated Circuity Humidity Sensor
HONEYWELL

HIH-4000-005

3 Pin, Unspecified, SIP-3
HONEYWELL

HIH-4010

Humidity Sensors
HONEYWELL