PX3AF1BH010BSAAX [HONEYWELL]

PRESSURE TRANSDUCER 10BAR UNF 7;
PX3AF1BH010BSAAX
型号: PX3AF1BH010BSAAX
厂家: Honeywell    Honeywell
描述:

PRESSURE TRANSDUCER 10BAR UNF 7

传感器 换能器
文件: 总10页 (文件大小:2278K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Heavy Duty Pressure Transducers  
32313757  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Issue F  
Datasheet  
Figure 2. PX3 Series External Freeze/Thaw Resistance  
(Shown with mating connector, see Figure 5.)  
• Reduced current consumption: Helps to reduce energy costs,  
and enhances product life if used in battery driven systems.  
• Media compatibility: Common HFC (hydrofluorocarbon)  
refrigerants (R410A and R134A), next generation low  
global warming potential (GWP) refrigerants (R448A/  
Solstice® N40, R32 and R1234ZE), engine oil, petroleum-  
based hydraulic fluids, brake fluids (DOT3), and dry air. For  
ammonia and other corrosive media, see Honeywell’s SPT Series.  
DIFFERENTIATION  
• Optional diagnostics mode: Beneficial in applications where  
the sensor functionality and the need to know internal or  
external failure modes is critical.  
DESCRIPTION  
Honeywell’s PX3 Series Heavy Duty Pressure Transducers  
use piezoresistive sensing technology with ASIC (Application  
Specific Integrated Circuit) signal conditioning in a brass  
housing and Metri-Pack 150, DIN, or cable harness electrical  
connections. The PX3 Series is calibrated and temperature  
compensated from -40°C to 125°C ꢁ-40°F to 257°F].  
• Great customer value: Multiple configuration possibilities  
provide flexibility of use in the application with no upfront  
NRE or tooling charges.  
• Durable: Provides the tough environmental specifications  
needed, including insulation resistance and dielectric  
strength, external freeze-thaw resistance (see Figure 2),  
and EMC performance.  
VALUE TO CUSTOMERS  
• 4 mA to 20 mA output is temperature compensated up to 125°C.  
• Total Error Band (TEB) 1.0 ꢀFSS from -20°C to 85°C:  
Provides indication of the sensor’s true measurement  
performance over a specified temperature range; small  
error promotes system uptime and efficiency. (See Figure 1.)  
FEATURES  
• Pressure range: 1 bar to 50 bar | 15 psi to 700 psi (absolute  
and sealed gage)  
• Ratiometric output: 0.5 Vdc to 4.5 Vdc or 0.33 Vdc to 2.97 Vdc  
• 4 mA to 20 mA output supports transmission of output  
signals over longer distances  
Figure 1. TEB Definition and Temperature Performance  
• Calibrated and temperature compensated  
• Total Error Band: 1.0 ꢀFSS from -20°C to 85°C ꢁ-4°F to 185°F]  
• External freeze/thaw resistance: 6 cycles from -30°C to  
50°C ꢁ-22°F to 122°F]  
Sources of Error  
Offset  
Full Scale Span  
Pressure Non-Linearity  
Total  
Error  
Band  
Accuracy  
BFSL  
• Insulation resistance: >100 MOhm, 1500 Vdc (in dry, non-  
ionized air)  
Pressure Hysteresis  
Pressure Non-Repeatability  
Thermal Effect on Offset  
Thermal Effect on Span  
Thermal Hysteresis  
• Dielectric strength: AC1500V, 1 min. or AC1800V, 1 s (in dry, non-  
ionized air)  
• Current consumption: 3.5 mA max.  
• EMC (radiated immunity): 200 V/m (ratiometric voltage  
output), 140 V/m (current output) per ISO 11452-2  
• Ingress protection IP67 (Metri-Pack connector), IP69K  
(cable harness), IP65 (DIN connector)  
3
2
1
Total Error Band  
• RoHS, REACH, and CE compliant  
0
-1  
-2  
-3  
• Six industry-standard pressure port types, including a tube port  
which provides for hermetically-sealed process connection  
POTENTIAL APPLICATIONS  
• Industrial: Refrigerant pressure monitoring in HVAC/R  
systems; dry air system pressure, process controls and  
automation  
-40°C  
[-40°F]  
0°C  
85°C  
[185°F]  
-20°C  
[-4°F]  
125°C  
[257°F]  
[32°F]  
Temperature (°C [°F])  
• Transportation: Dry air system monitoring; hydraulic, brake,  
and engine oil fluid pressure monitoring; air brake pressure  
monitoring  
• Higher insulation resistance and dielectric strength:  
Protects the user and sensor in high over-voltage  
situations, and ensures that the device is compliant with  
industry standards.  
• Higher EMC performance: Operates more reliably in the  
presence of electro-magnetic fields, such as near wireless  
signals, RF communication, and electrical devices.  
• Higher external freeze/thaw resistance: Survives exposure to  
frost, commonly found in refrigeration systems. (See Figure 2.)  
The PX3 Series is not recommended for use with media  
involving water, saturated air such as steam and vapor, and  
ammonia.  
PORTFOLIO  
Honeywell’s PX3 Series joins the PX2 Series, MLH Series, and  
SPT Series heavy duty pressure transducers.  
Sensing and Internet of Things  
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Table 1. Electrical Specifications  
Characteristic  
Parameter  
Supply voltage:  
ratiometric voltage output:  
5 Vdc  
5 Vdc 0.25 Vdc  
3 Vdc 0.25 Vdc  
3.3 Vdc  
current output:  
-40°C to 100°C  
>100°C to 125°C  
8 Vdc to 30 Vdc  
8 Vdc to 25 Vdc  
Over voltage and reverse voltage:  
ratiometric voltage output  
current output  
16 Vdc  
35 Vdc  
Current consumption:  
5 Vdc supply  
3.0 mA max.  
1.6 mA to 2.1 mA  
3.3 Vdc supply  
Short circuit protection  
yes  
Nominal output transfer function:  
5 Vdc supply  
0.5 Vdc to 4.5 Vdc (ratiometric to supply)  
0.33 Vdc to 2.97 Vdc (ratiometric to supply)  
4 mA to 20 mA  
3.3 Vdc supply  
8 Vdc to 30 Vdc supply  
Table 2. Performance Specifications (At 25°C [77°F] and under unless otherwise noted.)  
Characteristic  
Parameter  
Operating temperature range1  
Storage temperature range1  
Compensated temperature range  
-40°C to 125°C ꢁ-40°F to 257°F]  
-40°C to 125°C ꢁ-40°F to 257°F]  
-40°C to 125°C ꢁ-40°F to 257°F]  
Total Error Band2:  
-20°C to 85°C ꢁ-4°F to 185°F]  
<-20°C, >85°C ꢁ<-4°F, >185°F]  
1.0 ꢀFSS  
2.0 ꢀFSS  
Accuracy BFSL3  
Response time  
Turn on time4  
0.25 ꢀFSS  
<2 ms (10ꢀ to 90ꢀ step change in pressure)  
<7 ms  
EMC rating5:  
surge immunity (all leads)  
electrostatic discharge  
radiated immunity  
fast transient burst  
1000 V line to ground per IEC 61000-4-5  
4 kV contact, 8 kV air per IEC 61000-4-2  
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3  
1 kV per IEC 61000-4-4  
immunity to conducted disturbances 3 V per IEC 61000-4-6  
radiated emissions  
40 dBμV (30 MHz to 230 MHz), 47 dBμV (230 MHz to 1000 MHz) per CISPR 11  
radiated immunity:  
ratiometric (voltage) output  
4 mA to 20 mA (current) output  
200 V/m per ISO 11452-2  
140 V/m per ISO 11452-2  
Insulation resistance6:  
ratiometric voltage output  
current output  
>100 MOhm at 1500 Vdc  
>100 MOhm at 1000 Vdc  
Dielectric strength  
Load resistance6:  
<1 mA at 1500 Vac (1 min) or 1800 Vac (1 s)  
ratiometric voltage output  
current output  
>5 kOhm  
(Vin - 8) x 50 Ohm  
Life  
>10 million full scale pressure cycles over the calibrated pressure range  
1 Dependent on seal material. See Figure 5.  
2 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all  
errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect  
on span, and thermal hysteresis.  
3 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C  
ꢁ77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability.  
4 Turn on time: Duration from power applied until first valid output for voltage output. Typical value for 4 mA to 20 mA output.  
5 Tested using 1,5 m ꢁ59.1 in] long cable.  
6 Tested in dry, non-ionized air.  
Sensing and Internet of Things  
2
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Table 3. Pressure Reference Definitions  
Pressure Reference Definition  
Output is calibrated to be proportional to the difference between applied pressure and a fixed reference to  
perfect vacuum (absolute zero pressure).  
Absolute  
Sensor construction is identical to the absolute version with a built in reference at zero pressure in order to  
minimize measurement error over temperature. The output is calibrated to be proportional to the difference  
between applied pressure and a reference of 1 standard atmosphere (1.013 barA | 14.7 psiA). Example: 100  
psi sealed gage has a calibrated pressure range from 14.7 psi absolute to 114.7 psi absolute. (See Figure 3.)  
Sealed gage1  
1 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.  
Diagnostics Mode (For Ratiometric Voltage Output Only)  
Figure 3. Ratiometric Output Option AA for 100 psi,  
Absolute vs Sealed Gage  
The PX3 Series diagnostics mode allows the device to  
indicate when internal or external faults occur. If an internal  
fault occurs, the output will rail to the preset lower or upper  
limit values shown in Figure 4 and Table 5.  
5
4.5  
4
External faults will result in the sensor’s output exceeding  
those preset limits (lower or upper). (For example, if the  
external sensor ground (signal) were lost, the sensor output  
would exceed the upper rail of 97.5ꢀ.)  
3.5  
3
2.5  
100 psi absolute  
100 psi sealed gage  
2
1.5  
Figure 4. Analog Output with Diagnostics  
100  
1
0.5  
0
Upper Rail (97.5%)  
90  
80  
70  
60  
0
20  
40  
60  
80  
100  
120  
114.7  
140  
14.7  
Pressure (psi Absolute)  
50  
40  
30  
20  
Table 4. Pressure Ratings  
bar  
psi  
Operating Over-  
10  
Operating Over-  
Pressure pressure Pressure Pressure pressure Pressure  
Burst  
Burst  
Lower Rail (2.5%)  
0
10 20 30 40 50 60 70 80 90 100  
Pressure (psi)  
1
1.6  
2
5
8
15  
30  
70  
150  
250  
450  
450  
450  
450  
450  
1000  
1000  
1000  
1000  
1000  
-
115  
250  
400  
750  
750  
750  
1150  
1150  
1500  
1500  
1500  
1500  
1500  
-
5
8
Table 5. Output Transfer Function Codes  
Fault Condition  
10  
10  
17  
31  
31  
31  
31  
32  
69  
69  
69  
69  
69  
69  
69  
17  
50  
Analog Diagnostic Rail  
2.5  
4
17  
100  
150  
174  
200  
250  
300  
500  
600  
667  
700  
-
EEPROM Corrupt  
below lower rail  
27  
6
51  
Sensor Bridge Open  
(any element)  
above upper rail  
above upper rail  
8
51  
10  
12  
16  
20  
25  
30  
35  
40  
46  
50  
51  
Sensor Bridge Short  
(any element)  
51  
80  
Low supply voltage  
below lower rail  
above upper rail  
103  
103  
103  
103  
103  
103  
103  
Loss of ground connection  
-
-
-
-
-
-
-
-
-
Sensing and Internet of Things  
3
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Table 6. Environmental and Mechanical Specifications  
Characteristic  
Parameter  
Shock:  
threaded ports  
tube port  
100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C ꢁ77°F])  
100 G per MIL-STD-202F, Method 213B, and Condition C  
Vibration:  
threaded ports  
tube port  
20 G sweep, 10 Hz to 2000 Hz (at 25°C ꢁ77°F])  
10 Hz to 55 Hz, 2 mm displacement, tested as per IEC 60068-2-6; Test FC. (at 25°C ꢁ77°F])  
Ingress protection:  
Metri-Pack 150 electrical connector  
DIN electrical connector  
IP67  
IP65  
Cable harness electrical connector  
IP65, IP67, IP69K  
Ambient humidity  
0 ꢀRH to 95 ꢀRH, non-condensing  
External freeze/thaw resistance  
>6 cycles from -30°C to 50°C ꢁ-22°F to 122°F]  
Wetted materials:  
threaded ports  
brass C36000; lead (Pb) content: 3.7ꢀ max.  
external seals for ports  
tube port  
nitrile  
copper UNS C12200; lead (Pb) free  
braze filler  
silver and copper alloy  
internal O-ring media seal  
sensing element and substrate  
adhesives  
seal material based on application (see seal material media compatibility options below)  
alumina, glass, silicon  
epoxy  
Internal O-ring material media compatibility1:  
HNBR (option H)  
refrigerants, engine oil, petroleum-based hydraulic fluid  
dry air  
silicone (option S)  
Electrical connector material  
PBT 30ꢀ GF  
1 Honeywell can assist with selecting suitable O-ring seal material for the media based on the seal manufacturer’s recommendation. The customer  
should test the compatibility with the media to ensure that it is correct for the application.  
CAUTION  
PRODUCT DAMAGE TO TUBE PRESSURE PORT TYPE DURING BRAZING  
Ensure that the temperature of the brass port and plastic connector is maintained below 125°C during flame brazing.  
Exposure to temperatures higher than 125°C can cause permanent product damage and can compromise ingress protection  
leading to short circuits.  
Failure to comply with these instructions may result in product damage.  
CAUTION  
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES  
• Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating  
materials and thread sealants can result in significantly different torque values from one application to the next.)  
• When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling.  
Ensure the sealant is rated for the application.  
• Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.  
• Always hand-start transducers into the hole to prevent cross threading and damage.  
• Ensure that torque is not applied to the electrical connector.  
• Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged  
seals can compromise ingress protection, leading to short circuits.  
Failure to comply with these instructions may result in product damage.  
CAUTION  
PRODUCT DAMAGE DUE TO PARTICULATES AND SATURATED AIR  
Ensure that filters and dehumidifiers are used upstream of the transducers to keep media flow free of large particulates and  
condensed moisture. PX3 Series transducers are dead-end devices. Particulate accumulation may clog the port or damage  
the diaphragm. Condensing moisture may affect sensor output and lower insulation resistance.  
Failure to comply with these instructions may result in product damage.  
CAUTION  
PRODUCT DAMAGE DUE TO CONDUCTIVE MEDIA  
Ensure sensor is not used with conductive or ionic media. These media can affect sensor output and lower insulation resistance.  
Failure to comply with these instructions may result in product damage.  
Sensing and Internet of Things  
4
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 5. Nomenclature and Order Guide  
For example, PX3AN1BS150PAAAX defines a PX3 Series Heavy Duty Pressure Transducer, Metri-Pack 150,  
standard (UL V-0) electrical connector type, 1/4-18 NPT pressure port type, brass housing body, silicone:  
-40°C to 125°C [-40°F to 257°F] seal material and temperature range, 150 psi pressure range, absolute pressure  
reference, ratiometric: 0.5 Vdc to 4.5 Vdc output transfer function, no special  
PX3 A N1 B S 150P A AA X  
Special  
X
Series  
Heavy Duty  
PX3  
Pressure Transducer1  
Output Transfer Function  
AA Ratiometric: 5.0 V, 10% to 90% Vs  
DA Ratiometric: 5.0 V, 10% to 90% Vs (diagnostics on)6  
AC Ratiometric: 3.3 V, 10% to 90% Vs  
DC Ratiometric: 3.3 V, 10% to 90% Vs (diagnostics on)6  
CH Current: 4 mA to 20 mA  
Electrical Connector Type  
Metri-Pack 150,  
A
Standard (UL V-0)2  
DIN  
(Male, EN 175301-803C)  
C
Pressure Reference  
Absolute  
Sealed gage7  
PVC Cable3  
XLPE Cable3  
A
S
-40°C to 105°C -40°C to 125°C  
[-40°F to 221°F] [-40°F to 257°F]  
Pressure Range  
bar  
two or three  
22 AWG wires  
two or three  
22 AWG wires  
psi  
001B 1 bar  
016B 16 bar  
1.6B 1.6 bar 020B 20 bar  
002B 2 bar 025B 25 bar  
2.5B 2.5 bar 030B 30 bar  
015P 15 psi  
250P 250 psi  
300P 300 psi  
500P 500 psi  
0.5 m [1.3ft]  
1.0 m [3.2 ft]  
2.0 m [6.6 ft]  
3.0 m [9.8 ft]  
5.0 m [16.4 ft]  
K
E
F
L
M
N
P
030P 30 ps  
i
050P 50 psi  
100P 100 psi 600P 600 psi  
150P 150 psi 667P 667 psi  
174P 174 psi 700P 700 psi  
200P 200 psi  
004B 4 bar  
006B 6 bar  
008B 8 bar  
010B 10 bar 050B 50 bar  
012B 12 bar  
035B 35 bar  
040B 40 bar  
046B 46 bar  
G
H
Q
Three-wire cable is required  
for ratiometric Output Transfer  
Functions AA, DA, AC and DC;  
two-wire cable is required for  
Output Transfer Function CH.  
Internal O-ring Material and Temperature Range1, 8  
HNBR (Hydrogenated Nitrile Butadiene Rubber):  
H
-30°C to 125°C [-22°F to 257°F]  
S
Silicone: -40°C to 125°C [-40°F to 257°F]  
Three meter and five meter  
cables are only available  
with Output Transfer  
Function CH.  
Housing Body Material  
three-wire two-wire  
B Brass (C36000)  
Pressure Port Type4  
1 Not all catalog listing combinations are shown. Custom configurations,  
such as varied cable lengths, end mating connectors, different O-ring  
materials, and different pressure ranges are available. Please contact  
Honeywell.  
7/16-20 UNF  
1/4 inch 45° Flare  
Female Schrader  
F1  
(SAE J512)  
2 Metri-Pack 150 mating connectors with shielded cable and three 22 AWG  
wires are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft]  
cable length and part no. 3685302 for 3 m [9.8 ft] cable length.  
G1/4 A-G  
(ISO 1179-3)  
G1  
3 PVC Flame Retardant (FR) type cable is FT1 rated per IEC60332-1; XLPE  
non-flame retardant cable is FT2 rated per IEC60332-1.  
G1/4 A-L  
G2  
4 See Table for pressure port materials.  
(ISO 1179-2)  
5 Tube port is not available with DIN connector option.  
6 See page 3 for Diagnostics Mode information.  
M12 x 1.5  
(ISO 6149-3)  
7 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.  
8 See Table 6 for O-ring seal material media compatibility.  
M1  
1/4-18 NPT  
(ANSI/ASME B1.20.1)  
N1  
Mating Connector2  
1/8-27 NPT  
(ANSI/ASME B1.20.1)  
N2  
T1 Tube5  
Sensing and Internet of Things  
5
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 6. Metri-Pack Mounting Dimensions (For reference only. mm/[in].) E  
General product marking  
Pinout  
Ratiometric Voltage Output  
Pin A = Ground  
F1, G1, G2, M1, N1, N2  
T1  
Pin A  
Pin A  
Pin B = V+  
Pin C = Vout  
Yellow lettering  
22,0  
[0.87]  
Current Output  
Pin A = Return  
Pin B = Supply  
Pin C = Not connected  
Pin C  
Pin C  
Pin B  
Pin B  
F1: 7/16-20 UNF 1/4 inch 45° Flare  
Female Schrader (SAE J512)  
Seal: 45° cone  
G1: G1/4 A-G (ISO 1179-3)  
Seal: O-ring (included)  
G2: G1/4 A-L (ISO 1179-2)  
Seal: ISO 9974-2/DIN 3869 profile ring (included)  
Mating geometry: ISO 1179-1  
Mating geometry: ISO 1179-1  
Mating geometry: SAE J512  
Installation torque: 15 N m ꢁ11.1 ft-lb] max.  
Weight: 35,1 g to 40,1 g ꢁ1.2 oz to 1.4 oz]  
Installation torque: 15 N m ꢁ11.1 ft-lb] max.  
Weight: 35,1 g to 40.1 g ꢁ1.2 oz to 1.4 oz]  
Installation torque: 17 N m ꢁ12.5 ft-lb] max.  
Weight: 41 g to 46 g ꢁ1.4 oz to 1.6 oz]  
ø17,0  
ø17,0  
[0.67]  
ø17,0  
[0.67]  
[0.67]  
ø21,6  
ø21,6  
[0.85]  
ø21,6  
34,9  
[1.37]  
37,4  
[1.47]  
[0.85]  
35,9  
[0.85]  
[1.41]  
47,1  
[1.85]  
13,9  
48,9  
[1.93]  
49,6  
[1.95]  
12,9  
[0.51]  
15,4  
[0.61]  
[0.55]  
14,0  
[0.55]  
Profile ring  
12,2  
[0.48]  
11,2  
[0.44]  
O-ring  
7/16-20 UNF 1/4 in 45° Flare Female  
Schrader (SAE J512)  
G1/4 A-G (ISO 1179-3)  
G1/4 A-L (ISO 1179-2)  
ø15,9  
[0.63]  
M1: M12 x 1.5 (ISO 6149-3)  
Seal: O-ring (included)  
N1: 1/4-18 NPT  
Seal: Pipe thread  
Mating geometry: ISO 6149-1  
Mating geometry: ANSI B1.20.1  
Installation torque: 12 N m ꢁ8.85 ft-lb] max.  
Weight: 33,9 g to 38,9 g ꢁ1.2 oz to 1.4 oz]  
Installation torque: Two to three turns from finger tight  
Weight: 35,1 g to 40,1 g ꢁ1.2 oz to 1.4 oz]  
ø17,0  
ø17,0  
[0.67]  
[0.67]  
ø21,6  
ø21,6  
[0.85]  
[0.85]  
34,9  
[1.37]  
35  
[1.4]  
48,4  
[1.91]  
50  
[2.0]  
13  
[0.5]  
12,9  
[0.51]  
15,0  
[0.59]  
13,5  
[0.53]  
O-ring  
M12 x 1.5 (ISO 6149-3)  
1/4-18 NPT  
N2: 1/8-27 NPT  
T1: Tube  
ø17,0  
[0.67]  
Seal: Pipe thread  
Seal: Brazing  
Mating geometry: ANSI B1.20.1  
Weight: 32 g ꢁ1.1 oz]  
Installation torque: Two to three turns from finger tight  
Weight: 31,2 g to 36.2 g ꢁ1.1 oz to 1.3 oz]  
ø17,0  
[0.67]  
39,5  
[1.56]  
ø21,6  
96,5  
[3.80]  
[0.85]  
36  
[1.4]  
ø23,0  
[0.91]  
46  
[1.8]  
Ensure this area is  
protected during the  
brazing process so  
that temperatures  
do not exceed  
57,0  
[2.24]  
14  
[0.5]  
125°C [257°F].  
7,0  
[0.27]  
10,0  
[0.39]  
1/8-27 NPT  
ø7,3  
[0.29]  
ø6,35  
[0.25]  
Sensing and Internet of Things  
6
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 7. DIN Mounting Dimensions (For reference only. mm/[in].) E  
Pinout  
General product marking  
Ratiometric Voltage Output  
Pin 1 = Ground  
F1, G1, G2, M1, N1, N2  
Pin 4  
Pin 2  
Pin 2 = V+  
Pin 1  
Pin 3 = Vout  
Pin 4 (PE) = Not connected  
Yellow lettering  
22,0  
[0.87]  
Current Output  
Pin 1 = Return  
Pin 2 = Supply  
Pin 3  
Pin 3 = Not connected  
Pin 4 (PE) = Not connected  
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512)  
Seal: 45° cone  
G1: G1/4 A-G (ISO 1179-3)  
Seal: O-ring (included)  
Mating geometry: SAE J512  
Mating geometry: ISO 1179-1  
Installation torque: 17 N m ꢁ12.5 ft-lb] max.  
Weight: 42 g to 47 g ꢁ1.5 oz to 1.7 oz]  
Installation torque: 15 N m ꢁ11.1 ft-lb] max.  
Weight: 36,1 g to 41,1 g ꢁ1.3 oz to 1.4 oz]  
16,9  
[0.66]  
ø16,9  
[0.66]  
ø21,60  
[0.85]  
ø21,60  
[0.85]  
37,4  
[1.47]  
28,9  
[1.14]  
42,6  
[1.68]  
15,4  
[0.61]  
40,1  
13,9  
[1.58]  
[0.55]  
12,2  
[0.48]  
O-ring  
11,2  
[0.44]  
7/16-20 UNF 1/4 in 45° Flare Female  
Schrader (SAE J512)  
G1/4 A-G (ISO 1179-3)  
ø15,9  
[0.63]  
G2: G1/4 A-L (ISO 1179-2)  
M1: M12 x 1.5 (ISO 6149-3)  
Seal: O-ring (included)  
Seal: ISO 9974-2/DIN 3869 profile ring (included)  
Mating geometry: ISO 1179-1  
Mating geometry: ISO 6149-1  
Installation torque: 15 N m ꢁ11.1 ft-lb] max.  
Weight: 36,1 g to 41,1 g ꢁ1.3 oz to 1.4 oz]  
Installation torque: 12 N m ꢁ8.85 ft-lb] max.  
Weight: 34,9 g to 39,9 g ꢁ1.2 oz to 1.4 oz]  
,
ø16,9  
ø17,0  
[0.66]  
[0.67]  
ø21,60  
[0.85]  
ø21,60  
27,9  
[1.10]  
[0.85]  
27,9  
[1.10]  
41,9  
[1.65]  
41,4  
[1.63]  
12,9  
[0.51]  
12,9  
[0.51]  
14,0  
[0.55]  
13,5  
[0.53]  
Profile ring  
O-ring  
M12 x 1.5 (ISO 6149-3)  
G1/4 A-L (ISO 1179-2)  
N1: 1/4-18 NPT  
N2: 1/8-27 NPT  
Seal: Pipe thread  
Seal: Pipe thread  
Mating geometry: ANSI B1.20.1  
Mating geometry: ANSI B1.20.1  
Installation torque: Two to three turns from finger tight  
Weight: 36,1 g to 41,1 g ꢁ1.3 oz to 1.4 oz]  
Installation torque: Two to three turns from finger tight  
Weight: 32,2 g to 37,2 g ꢁ1.1 oz to 1.3 oz]  
ø16,9  
ø16,9  
[0.66]  
[0.66]  
ø21,60  
[0.85]  
ø21,6  
29  
[1.1]  
28  
[1.1]  
[0.85]  
13  
43  
39  
[1.5]  
[0.5]  
[1.7]  
14  
[0.5]  
15,0  
[0.59]  
10,0  
[0.39]  
1/4-18 NPT  
1/8-27 NPT  
Sensing and Internet of Things  
7
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 8. Cable Harness Mounting Dimensions (For reference only. mm/[in].)  
Wire colors  
F1, G1, G2, M1, N1, N2  
T1  
General product marking  
22,0  
[0.87]  
3-wire  
cable  
Voltage Output  
Black = Ground  
Red = V+  
White = Vout  
White label with  
black lettering  
Current Output  
Black = Return  
Red = Supply  
22,0  
[0.87]  
2-wire  
cable  
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512) G1: G1/4 A-G (ISO 1179-3)  
Seal: 45° cone  
Seal: O-ring (included)  
Mating geometry: SAE J512  
Installation torque: 17 N m ꢁ12.5 ft-lb] max.  
Weight: 90 g to 88 g ꢁ3.2 oz to 3.1 oz]  
Mating geometry: ISO 1179-1  
Installation torque: 15 N m ꢁ11.1 ft-lb] max.  
Weight: 70 g to 68 g ꢁ2.5 to 2.4 oz]  
3-Wire  
Cable  
2-Wire  
Cable  
3-Wire  
Cable  
2-Wire  
Cable  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
33,1  
[1.30]  
31,6  
[1.24]  
ø
21,6  
ø21,6  
[0.85]  
[0.85]  
45,3  
[1.78]  
42,75  
[1.683]  
15,4  
[0.61]  
13,9  
[0.55]  
7/16-20 UNF 1/4 in 45° Flare  
Female Schrader (SAE J512)  
12,2  
[0.48]  
11,2  
[0.44]  
O-Ring  
G1/4 A-G (ISO 1179-3)  
ø
15,9  
[0.63]  
G2: G1/4 A-L (ISO 1179-2)  
M1: M12 x 1.5 (ISO 6149-3)  
Seal: O-ring (included)  
Seal: ISO 9974-2/DIN 3869 profile ring (included)  
Mating geometry: ISO 1179-1  
Mating geometry: ISO 6149-1  
Installation torque: 12 N m ꢁ8.85 ft-lb] max.  
Weight: 69 g to 67 g ꢁ2.4 oz]  
Installation torque: 15 N m ꢁ11.1 ft-lb] max.  
Weight: 70 g to 68 g ꢁ2.5 oz to 2.4 oz]  
3-Wire  
2-Wire  
Cable  
3-Wire  
Cable  
2-Wire  
Cable  
Cable  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
30,6  
[1.20]  
30,6  
[1.20]  
ø21,6  
[0.85]  
ø21,6  
[0.85]  
44,55  
[1.754]  
12,9  
[0.51]  
44,1  
12,9  
[1.73]  
[0.51]  
14,0  
[0.55]  
Profile ring  
G1/4 A-L (ISO 1179-2)  
13,5  
[0.53]  
O-Ring  
M12 x 1.5 (ISO 6149-3)  
Sensing and Internet of Things  
8
Heavy Duty Pressure Transducers  
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi  
Figure 8. Cable Harness Mounting Dimensions (For reference only. mm/[in].)  
N1: 1/4-18 NPT  
N2: 1/8-27 NPT  
Seal: Pipe thread  
Seal: Pipe thread  
Mating geometry: ANSI B1.20.1  
Installation torque: Two to three turns from finger tight  
Weight: 70 g to 68 g ꢁ2.5 oz to 2.4 oz]  
Mating geometry: ANSI B1.20.1  
Installation torque: Two to three turns from finger tight  
Weight: 66 g to 64 g ꢁ2.3 oz]  
3-Wire  
Cable  
2-Wire  
Cable  
3-Wire  
Cable  
2-Wire  
Cable  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
30,6  
[1.20]  
31,6  
[1.24]  
ø21,6  
[0.85]  
ø21,6  
[0.85]  
45,6  
[1.79]  
12,9  
[0.51]  
41,6  
[1.64]  
13,9  
[0.55]  
15,0  
[0.59]  
10,0  
[0.39]  
1/4-18 NPT  
1/8-27 NPT  
T1: Tube  
3-Wire  
Cable  
2-Wire  
Cable  
Seal: Brazing  
Weight: 67 g ꢁ2.4 oz]  
1000 50  
[39.9 1.9]  
1000 50  
[39.9 1.9]  
ø23,0  
[0.91]  
32,2  
[1.38]  
92,2  
[3.63]  
Ensure this area is  
protected during the  
brazing process so that  
temperatures do not  
exceed 125°C [257°F].  
57,0  
[2.24]  
7,0  
[0.27]  
ø7,3  
[0.29]  
ø6,35  
[0.25]  
Sensing and Internet of Things  
9
ADDITIONAL INFORMATION  
The following associated literature is available on the  
Honeywell web site at sensing.honeywell.com:  
WARNING  
PERSONAL INJURY  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
• Product line guide  
• Product range guide  
• Product installation instructions  
• Application notes:  
Failure to comply with these instructions could result in  
death or serious injury.  
- Heavy Duty Pressure Transducers, PX2 Series and  
PX3 Series  
WARNING  
- PX2 Series and PX3 Series Heavy Duty Pressure  
Transducers for Potential Use in Industrial Refrigeration  
MISUSE OF DOCUMENTATION  
The information presented in this datasheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
- PX2 Series and PX3 Series Heavy Duty Pressure  
Transducers for Potential Use in Industrial HVAC/R  
Applications  
• Technical notes:  
- Total Error Band Specification for Honeywell Heavy  
Duty Pressure Transducers, PX2 Series and PX3 Series  
Failure to comply with these instructions could result in  
death or serious injury.  
- Media Compatibility for Honeywell Heavy Duty  
Pressure Transducers, PX2 Series and PX3 Series  
• CAD models  
Warranty/Remedy  
Honeywell warrants goods of its manufacture as being free  
of defective materials and faulty workmanship during the  
applicable warranty period. Honeywell’s standard product  
warranty applies unless agreed to otherwise by Honeywell  
in writing; please refer to your order acknowledgement or  
consult your local sales office for specific warranty details.  
If warranted goods are returned to Honeywell during the  
period of coverage, Honeywell will repair or replace, at its  
option, without charge those items that Honeywell, in its sole  
discretion, finds defective. The foregoing is buyer’s sole  
remedy and is in lieu of all other warranties, expressed or  
implied, including those of merchantability and fitness for  
a particular purpose. In no event shall Honeywell be liable  
for consequential, special, or indirect damages.  
While Honeywell may provide application assistance  
personally, through our literature and the Honeywell web site, it  
is buyer’s sole responsibility to determine the suitability of the  
product in the application.  
For more information  
Honeywell Sensing and Internet of  
Things services its customers through a  
worldwide network of sales offices and  
distributors. For application assistance,  
current specifications, pricing or the  
nearest Authorized Distributor, visit  
sensing.honeywell.com or call:  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this writing.  
However, Honeywell assumes no responsibility for its use.  
Asia Pacific  
Europe  
USA/Canada  
+65 6355-2828  
+44 (0) 1698 481481  
+1-800-537-6945  
Solstice® N40 is a registered trademark  
of Honeywell International Inc.  
Honeywell Sensing and Internet of Things  
9680 Old Bailes Road  
Fort Mill, SC 29707  
32313757-F-EN | F | 07/19  
© 2019 Honeywell International Inc.  
www.honeywell.com  

相关型号:

PX3AF1BH020BSAAX

PRESSURE TRANSDUCER 20BAR UNF 7
HONEYWELL

PX3AF1BH100PSAAX

PRESSURE TRANSDUCER 100PSI UNF 7
HONEYWELL

PX3AF1BH150PSAAX

PRESSURE TRANSDUCER 150PSI UNF 7
HONEYWELL

PX3AF1BH300PSAAX

PRESSURE TRANSDUCER 300PSI UNF 7
HONEYWELL

PX3AF1BH500PSAAX

PRESSURE TRANSDUCER 500PSI UNF 7
HONEYWELL

PX3AF1BH667PSCHX

Peizoresistive Sensor,
HONEYWELL

PX3AF1BS300PSCHX

Peizoresistive Sensor,
HONEYWELL

PX3AG1BH010BSAAX

PRESSURE TRANSDUCER 10BAR G1/4
HONEYWELL

PX3AN1BH100PSAAX

PRESSURE TRANSDUCER 100PSI NPT 1
HONEYWELL

PX3AN1BS025BSCHX

Peizoresistive Sensor,
HONEYWELL

PX3AN2BS250PAAAX

PRESSURE TRANSDUCER 250PSIA NPT
HONEYWELL

PX3EG1BS016BSCHX

Peizoresistive Sensor,
HONEYWELL