ISSUE 1
Installation Instructions for the
SS431P Hall Effect Sensor
PK 80076
ABSOLUTE MAXIMUM RATINGS*
WARNING
Supply voltage
-1 to +30 VDC
PERSONAL INJURY
Voltage externally
applied to output
+30 VDC max. (OFF only)
-0.5 VDC min. (OFF or ON)
• DO NOT USE these products as safety or
emergency stop devices, or in any other
application where failure of the product could
result in personal injury.
Failure to comply with these instructions could
result in death or serious injury.
Output ON current
Storage Temperature
Magnetic flux
50 mA max.
-65 to +160°C (-85 to +320°F)
No limit. Circuit cannot be
damaged by magnetic
overdrive.
*Absolute maximum ratings are the extreme limits that
the device will withstand without damage to the device.
However, the electrical and mechanical characteristics
are not guaranteed as the maximum limits (above
recommended operating conditions) are approached, nor
will the device necessarily operate at absolute maximum
ratings.
NOTICE
SOLDERING/ASSEMBLY
Interruption of power to a bipolar or latching
device may cause the output to change state when
power is restored. If a magnetic field of sufficient
strength is present, the sensor output will be in the
condition dictated by the magnetic field.
Leads must be adequately supported during any
forming/ shearing operation to ensure that the leads
are not stressed inside the plastic case. Recom-
mended PC board wave soldering temperature is
250 to 260oC (482 to 500oF) for 3 seconds
maximum.
NOTE: The SS431P is a 2-wire, current output
sensor.
OPERATING CHARACTERISTICS
Min.
25°C
Max.
Remarks
Target
Supply voltage
ICC Operate
3.8
11
4
24
20
9
VDC
mA
15
6
mA
ICC Released
2.0
2.5
4.0
mA
ICC Ratio (Op/Rel)
Output switching time
Rise, 10 to 90%
Fall, 90 to 10%
30 µs
30 µs
VCC = 12 V. RL = 300 Ω,
CL = 33 nF, CS = 330 pF
Operating Temperature
-55 to +160°C (-67 to +320°F)
MAGNETIC SPECIFICATIONS
Temperature Range
Max. Operate Gauss
Min. Release Gauss
Min. Differential Gauss
-40°C
0°C
65
25°C
60
85°C
125°C
65
150°C
70
-70
15
60
-60
12
70
-70
10
-65
15
-60
15
-65
12
HONEYWELL Sensing and Control
SS431P Hall Effect Sensor
ISSUE 1 PK 80076
BLOCK DIAGRAM
GAUSS VS. TEMPERATURE
2 Honeywell • Sensing and Control
For application help: call 1-800-537-6945
SS431P Hall Effect Sensor
ISSUE 1 PK 80076
MOUNTING DIMENSIONS (for reference only)
NOTES
1.Magnetic flux used to operate the sensor must be
in the direction and location shown (this assumes
the convention that the direction of the external
flux of a magnet is from the north to the south
pole of the magnet.
2.The magnetic field strength (gauss) required to
cause the sensor to change state (operate and
release) will be as shown on page 1. To test the
sensor against the specified limits, the sensor
must be placed in a uniform magnetic field.
3.Part dimensions do not include flash. Flash is
limited to .005” max.
4.Lead dimension refers to location of lead
centerlines as they exit the plastic package.
For application help: call 1-800-537-6945
Honeywell • Sensing and Control 3
SS431P Hall Effect Sensor
ISSUE 1 PK 80076
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of
coverage, Honeywell will repair or replace without
charge those items it finds defective. The foregoing
is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including
those of merchantability and fitness for a
particular purpose.
For application assistance, current specifications,
pricing or name of the nearest Authorized
Distributor, contact a nearby sales office. Or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
http://www.honeywell.com/sensing/
info@micro.honeywell.com
Specifications may change without notice. The
information we supply is believed to be accurate
and reliable as of this printing. However, we assume
no responsibility for its use.
While we provide application assistance,
personally and through our literature, it is up to the
customer to determine the suitability of the product
in the application.
Honeywell Inc.
11 West Spring Street
Freeport, Illinois 61032
PrintedwithSoyInk
on 50%Recycled Paper
PK 80076-1-EN IL50 GLO 698 Printed in USA
相关型号:
©2020 ICPDF网 联系我们和版权申明