SZR-MY2-1-DC12V [HONEYWELL]
Power/Signal Relay, DPDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Panel Mount;型号: | SZR-MY2-1-DC12V |
厂家: | Honeywell |
描述: | Power/Signal Relay, DPDT, Momentary, 0.075A (Coil), 12VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Panel Mount 光电二极管 继电器 |
文件: | 总10页 (文件大小:545K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General Purpose
Power Relay
SZR-MY Series
FEATURES
• Small package design
• DPDT has a fine silver
contact with 5 A capability
• 4PDT has a gold-plated
silver contact with 3 A
capability
• High dielectric strength
(1,800 Vac)
• High reliability and long life
• Ultra-high sensitivity with
quick response time
(20 ms max.)
• Options include LED
indicator, diode protection,
and LED indicator/diode
protection
• UL listed, CE certified,
CSA certified
®
SZR-MY Series general-purpose power relays are designed for a wide
range of applications including power as well as logic control for factory
machines and control panels.
SZR-MY Series relays have a small package design for multiple
application needs. Relays are available in two configurations: DPDT with a
5A load and 4PDT with a 3 A load.
One standard and three options are available: LED indicator, internal
surge protection diode, and LED indicator/diode protection. Honeywell’s
global sales and distribution channels ensure a rapid response and excellent
customer service.
TYPICAL APPLICATIONS
• Control panels
• Elevator panels
• Machine tools
• Test equipment
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
General Purpose
Power Relays
SZR-MY Series
RELAY MODEL SELECTION GUIDE
Type
Catalog Listing
Terminal
Contact
DPDT
4PDT
DPDT
4PDT
DPDT
4PDT
DPDT
4PDT
DPDT
4PDT
SZR-MY2-1
SZR-MY4-1
Standard
Plug-in/Solder
SZR-MY2-1P
SZR-MY4-1P
SZR-MY2-N1
SZR-MY4-N1
SZR-MY2-D1
SZR-MY4-D1
SZR-MY2-X1
SZR-MY4-X1
PCB
LED Indicator
Plug-in/Solder
DIODE surge suppression
LED indicator + surge suppression
SOCKETS – REQUIRED ACCESSORIES
Din-rail Mounting
Solder Terminal
PCB Terminal
Relay Contact
DPDT
For use with
SZR-MY2-1, -N1, -
D1, -X1
SZX-SMB-08P
SZX-SMF-08N
SZX-SMB-08
4PDT
For use with
SZR-MY4-1, -N1, -
D1, -X1
SZX-SMB-14P
SZX-SMF-14N
SZX-SMB-14
2
Honeywell • Sensing and Control
General Purpose
Power Relays
SZR-MY Series
CONTACT RATINGS
Type
DPDT
4PDT
Load Resistive Load (p.f. = 1)
Inductive load
Resistive Load (p.f. = 1)
Inductive load
Ratings
(p.f. = 0.4, L/R = 7 ms)
(p.f. = 0.4, L/R = 7 ms)
Rated load
220 Vac, 5A
24 Vdc, 5A
220 Vac, 2A
24 Vdc, 2A
220 Vac, 3A
24 Vdc, 3A
220 Vac, 0.8 A
24 Vdc, 1.5 A
Carry current
Max. operating
voltage
5A
3A
250 Vac, 125 Vdc
250 Vac, 125 Vdc
Max. operating
current
5 A
3 A
Max. switching
capacity
1,100 VA, 120 W
440 VA, 48 W
660 VA, 72 W
176 VA, 16 W
Min. permissible
load
1 mA, 5 Vdc
1 mA, 1 Vdc
COIL RATINGS
Rated Current
(mA)
Coil Inductance (H)
Armature Armature Pick-up Dropout Maximum
Rated
Voltage
(V)
50 Hz
60 Hz
Coil
Power
Consumption
(W)
resistance
OFF
ON
Voltage Voltage
Voltage
(V)
(V)
(V)
(Ω)
12.2
6
214.1
106.5
53.8
183
91
0.04
0.17
0.69
3.22
14.54
19.2
54.75
83.5
0.17
0.73
3.2
0.08
0.33
1.3
Approx.
1.0 W to 1.2 W
(60 Hz)
12
24
46
46
180
Max.
75 %
Min.
30%
AC
50
25.7
22
788
5.66
24.6
32.1
94.07
136.4
0.33
1.37
5.72
21.0
86.2
110%
100/110 11.7/12.9 10/11
110/120 9.9/10.8 8.4/9.2
3,750
4,430
12,950
18,790
Approx
0.9 W to 1.1 W
(60 Hz)
200/220
220/240
6
6.2/6.8
4.8/5.3
5.3/5.8
4.2/4.6
150
40
160
12
75
Max.
75%
Min.
10%
Approx.
0.9 W
DC
24
36.9
18.5
650
110%
48
2,600
11,000
10.6
45.6
100/110
9.1/10
Note 1: The rated current and coil resistance are measured at a coil temperature of 23 °C [73.4 °F] with tolerances of +15%,
-20% for AC rated current and 15% for DC coil resistance.
Note 2: The rated current of N1 and X1 types is 4 mA higher than the value in the table above.
Honeywell • Sensing and Control
3
General Purpose
Power Relays
SZR-MY Series
SPECIFICATIONS
Contact material
Contact resistance
Operate time
Silver
Max. 50 MOhm
Max. 20 ms
Release time
Max. 20 ms
Operating
frequency
Mechanical
Electrical
18,000 operations per hour
1,800 operations per hour
Insulation resistance
Min. 100 Mw at 500 Vdc
Dielectric withstand voltage
1,800 Vac 50 Hz/60 Hz for one minute between non-continuous current
carrying terminals and between coil thermals and contact terminals
10 Hz to 55 Hz at double amplitude of 1.0 mm
Vibration
resistance
Mechanical durability
Malfunction durability
10 Hz to 55 Hz at double amplitude of 1.0 mm
Shock resistance Mechanical durability
Malfunction durability
1,000 m/s2 (approx. 100 g)
200 m/s2 (approx. 20 g)
Service life
Mechanical
AC: Min. 50 million operations (at operating frequency of 18,000 operations/hour)
DC: Min. 100 million operations (at operating frequency of 18,000 operations/hour)
DPDT: Min. 500,000 operations (at operating frequency of 1,800 operations/hour)
4PDT: Min. 200,000 operations (at operating frequency of 1,800 operations/hour)
Approximately 35 g
Electrical
Weight
Note 1: The data shown above are of initial value
CHARACTERISTIC DATA
Max.
Switchin
g capac
ity
Resi
stive Loa
d
Ind
uctive L
oad
AC resistive
1,000
500
1,000
500
10
5
AC110V
AC220V
AC110V p.f.=0.4
AC220V p.f.=0.4
DPDT
AC inductive
p.f.=0.4
DC resistive
100
50
100
50
1
0.5
DC inductive
L/R=7ms
DC24V
DC24V L/R=7ms
1
10
10
0.1
0
1
2
3
4
5
6
7
8
0
2
5
10
50 100
500
Current(A)
Rated operating voltage(V)
Current(A)
Ma
x. Switc
Resist
Ind
ive Load
uctive L
oad
hing cap
acity
1,000
500
1,000
500
10
5
4PDT
AC resistive
AC110V
3
AC110V p.f.=0.4
AC220V
AC inductive
p.f.=0.4
DC30V L/R=7ms
100
50
100
50
DC resistive
1
0.5
0.1
DC inductive
L/R=7ms
AC220V p.f.=0.4
DC30V
10
10
0
0.5
1
1.5
Current(A)
0
1
2
3
5
100
10
50
500
Current(A)
Rated operating voltage(V)
4
Honeywell • Sensing and Control
General Purpose
Power Relays
SZR-MY Series
HOLDING CLIPS
•
•
•
•
Holding clips are included with the sockets
Holding clips for the SMF-08N and SMF-14N cannot be removed once inserted
Holding clips for all SMB sockets are wire for easy removal
Holding clips are to be inserted into the slots provided on the socket
DIMENSIONS (For reference only – mm/in)
Figure 1. Dimensions
For SZX-SMF-08N and SZX-SMF-14N sockets
Figure 2. Dimensions
For all SZX-SMB sockets
29,0 [1.14]
6,5
[0.26]
5,0
[0.20]
14,5
[0.57]
4,6 [0.18]
6,2
[0.24]
49,9 [1.96]
Honeywell • Sensing and Control
5
General Purpose
Power Relays
SZR-MY Series
CATALOG LISTING MATRIX
SZR – MY 2 - ___ 1 P - AC110-120V
Voltage Rating:
AC6V
=
=
=
=
=
6 Vac
Terminal Type
__ = Solder/Plug-in
P = PCB
AC12V
AC24V
AC50V
AC100V
12 Vac
24 Vac
50 Vac
100 Vac
Mounting Type
1 = Terminal
AC110-120V = 110/120 Vac
AC200V
AC220V
AC220-240V = 220/240 Vac
=
=
200 Vac
220 Vac
Option Type
__ = No Indicator or Diode
D = Internal Surge Protection Diode
N = Red LED Operation Indicator
X = LED and Diode
Poles
2 = DPDT
4 = 4PDT
DC6V
=
=
=
=
=
6 Vdc
DC12V
DC24V
DC48V
DC100V
12 Vdc
24 Vdc
48 Vdc
100 Vdc
Amp Rating:
MY = 5 A or 3 A
LY = 10 A
Product Type
General Purpose Relay
6
Honeywell • Sensing and Control
General Purpose
Power Relays
SZR-MY Series
FIGURE 3. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR
SZR-MY2-1, SZR-MY2-N1, SZR-MY2-D1, and SZR-MY2-X1
8 - O 1,2 [0.05] x 3 Holes
0,5
[0.02]
Max. 21,5
[0.85]
Max. 36,0 [1.42]
6,0
[0.24]
MY2-1
MY2-N1 AC
MY2-N1 DC
MY2-D1
MY2-X1
1
5
4
8
1
4
8
1
5
4
8
1
5
4
8
1
5
4
8
5
9
12
14
9
12
14
9
12
14
9
12
14
9
12
-
+
-
+
-
+
13
13
13
13
13
14
Bottom view
FIGURE 4. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR
SZR-MY2-1P and SZR-MY4-1P
3,5
[0.14]
0,5
[0.02]
Max. 21,5
[0.85]
6,0
Max. 36,0 [1.42]
[0.24]
The circuit diagram is the same wit standard type of SZR-MY2-1 or the SZR-MY4-1
Honeywell • Sensing and Control
7
General Purpose
Power Relays
SZR-MY Series
FIGURE 5. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR
SZR-MY4-1, SZR-MY4-N1, SZR-MY4-D1, and SZR-MY4-X1
14 - O 1.2 [0.05] x 3 Holes
Max. 21,5
[0.85]
0,5
[0.02]
Max. 36,0 [1.42]
6,0
[0.24]
MY4-1
MY4-N1 AC
MY4-N1 DC
MY4-D1
MY4-X1
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
1
5
2
6
3
7
4
8
10 11
12
14
10 11
9
10 11 12
14
9
9
12
14
9
10 11 12
9
10 11 12
-
+
-
+
-
+
13
13
13
13
14
13
14
-
-
Bottom view
FIGURE 6. CIRCUIT DRAWING FOR SZR-MY2- and SZR-MY4-
4PDT
13.2
DPDT
13.2
0.1
14- 1.3
4.4
0.1
3.75
8- 1.3
8
Honeywell • Sensing and Control
General Purpose
Power Relays
SZR-MY Series
SOCKETS
FIGURE 7. SZX-SMF-08N
FIGURE 8. SZX-SMF-14N
6,0
[0.24]
6,0
[0.24]
3,9
[0.15]
3,9
[0.15]
26,0
[1.02]
26,0
[1.02]
2-M3 or 2-M4
2-M3 or 2-M4
2 - O 4,5 [0.18] Holes
2 - O 4,5 [0.18] Holes
18,0
[0.70]
26,0 [1.02]
18,0
26,0 [1.02]
[0.70]
30,0 [1.18]
25,0 [0.99]
25,0 [0.99]
30,0 [1.18]
FIGURE 9. SZX-SMB-08
FIGURE 10. SZX-SMB-14
14 - 3 x O 1,2 [0.05] Holes
8 - 3 X O 1,2 [0.05] Holes
Max 24,0 [0.94]
Max. 24,0 [0.94]
7,7
[0.30]
2,7
[0.11]
2,6
[0.10]
2,7
[0.11]
7,7
[0.30]
2,6 [0.10]
Max. 20,0
[0.79]
Max. 20,0
[0.79]
21,4 ± 0,2
0.84 ± .008
21,4 ± 0,2
[0.84 ± .008]
Honeywell • Sensing and Control
9
General Purpose
Power Relays
SZR-MY Series
FIGURE 11. SZX-SMB-08P
FIGURE 12. SZX-SMB-14P
4,3
[0.17]
4,3
[0.17]
Max. 22,0
[0.87]
Max. 22,0 [0.87]
2,7
[0.11]
2,7
[0.11]
2,6
[0.10]
2,6
[0.10]
Max. 16,5
[0.65]
13,2
[0.52]
Max. 16,5
[0.65]
4,4
13,2
[0.17]
[0.52]
14 - O 2,0 [0.08] Holes
4,2
[0.17]
8 - O 2,0 [0.08] Holes
4,2
[0.17]
WARRANTY/REMEDY
While we provide application assistance
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of
coverage, Honeywell will repair or replace without
charge those items it finds defective. The
foregoing is Buyer’s sole remedy and is in lieu
of all other warranties, expressed or implied,
including those of merchantability and fitness
for a particular purpose.
personally, through our literature and the
Honeywell web site, it is up to the customer to
determine the suitability of the product in the
application.
For application assistance, current specifications,
or name of the nearest Authorized Distributor,
contact a nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
Specifications may change without notice. The
information we supply is believed to be accurate
and reliable as of this printing. However, we
assume no responsibility for its use.
www.honeywell.com/sensing
info.sc@honeywell.com
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
009550-4-EN IL50 GLO 0104 Printed in USA
Copyright 2003-2004 Honeywell International Inc. All Rights Reserved.
相关型号:
SZR-MY2-1-DC24V
Power/Signal Relay, DPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Panel Mount
HONEYWELL
SZR-MY2-1P-AC220-240V
Power/Signal Relay, DPDT, Momentary, 1100mW (Coil), AC Input, AC Output, Through Hole-Straight Mount
HONEYWELL
SZR-MY2-1P-DC24V
Power/Signal Relay, DPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount
HONEYWELL
SZR-MY2-D1-DC24V
Power/Signal Relay, DPDT, Momentary, 0.037A (Coil), 24VDC (Coil), 900mW (Coil), 5A (Contact), 125VDC (Contact), DC Input, DC Output, Panel Mount
HONEYWELL
SZR-MY2-N1-AC220V
Power/Signal Relay, DPDT, Momentary, 1100mW (Coil), AC Input, AC Output, Panel Mount
HONEYWELL
©2020 ICPDF网 联系我们和版权申明