XPC01DFH [HONEYWELL]

Peizoresistive Sensor, Differential, 17-19mV, Panel Mount, Through Hole Mount;
XPC01DFH
型号: XPC01DFH
厂家: Honeywell    Honeywell
描述:

Peizoresistive Sensor, Differential, 17-19mV, Panel Mount, Through Hole Mount

输出元件 传感器 换能器
文件: 总4页 (文件大小:512K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
XPC/XPCL Series and  
XPXL Series  
Compensated/Calibrated and  
Uncompensated/Uncalibrated  
Board Mount Pressure Sensors  
DESCRIPTION  
The XPC/XPCL Series and XPXL Series sensors integrate  
silicon micromachined sensing technology, temperature  
compensation, and calibration in a complete family of low-cost  
packages. This series offers a cost-effective solution for design  
requirements.  
On devices of 5 psi and above, the top side of the chip is  
protected against humidity by a Silgel® coating.  
Although the sensors are designed for use with noncorrosive,  
nonionic pressure media, they accommodate many gases that  
are used in medical applications.  
These piezoresistive pressure sensors use micromachined  
silicon chips mounted on ceramic and protected with a plastic  
cap. Several tube arrangements with nylon housings are  
available for various pressure applications.  
FEATURES  
POTENTIAL APPLICATIONS  
Medical applications  
Low cost, small size  
Temperature compensated  
Zero and span calibrated  
Millivolt output  
Applications requiring small size  
Applications requiring vacuum and positive pressure  
reference or both  
Differential, gage and absolute pressure  
Constant voltage excitation  
High impedance - low current  
XPC/XPCL Series and XPXL Series  
Table 1. Electrical Specifications  
Characteristic  
XPC/XPCL at 12 Vdc, 25 °C [77 °F]  
XPXL at 5 Vdc, 25 °C [77 °F]  
Unit  
Min.  
3.0  
-1.0  
Typ.  
12.0  
0
Max.  
16.0  
1.0  
Min.  
3.0  
-50  
Typ.  
5.0  
0
Max.  
12.0  
50  
Excitation voltage  
Null  
Vdc  
mV  
Offset temperature shift1  
±1.0  
±0.5  
mV  
0 C to 25 C [32 F to 77 F]  
25 C to 70 C [77 F to 158 F]  
Full scale temperature shift1  
-1800  
PPM/ C  
±2  
% span  
0 C to 25 C [32 F to 158 F]  
25 C to 70 C [77 F to 158 F]  
Linearity, hysteresis error2  
Input resistance  
5.0  
0.25  
3.0  
1.0  
0.25  
3.0  
3.0  
1.0  
% span  
kOhm  
kOhm  
C [ F]  
C [ F]  
psi  
Output resistance  
Operating temperature  
Storage temperature  
Common mode pressure  
-25 [-13]  
-40 [-40]  
85 [185]  
125 [257]  
50  
-25 [-13]  
-40 [-40]  
85 [185]  
125 [257]  
50  
Notes:  
1. Shift is relative to 25 °C [77 °F].  
2. Measured at 1/2 full scale rated pressure using BFSL.  
Table 2. Absolute Output  
FS Pressure  
XPC at 12 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
Overpressure  
(psi)  
Max.  
15  
45  
90  
180  
250  
Min.  
Max.  
Max.  
5 psi  
57  
85  
85  
85  
95  
60  
63  
95  
95  
15 psi  
30 psi  
60 psi  
100 psi  
90  
90  
90  
100  
95  
105  
Table 3. Gage/Differential1 Output  
FS Pressure  
XPC/XPCL at 12 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
XPXL at 5 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
Overpressure  
(psi)  
Max.  
3
Min.  
23  
19  
17  
57  
85  
85  
85  
95  
85  
Typ.  
Max.  
Min.  
Typ.  
68  
78.5  
75  
Max.  
4 inH2O  
10 inH2O  
1 psi  
25  
27  
50  
45  
40  
86  
20  
21  
112  
110  
225  
338  
338  
338  
380  
338  
3
3
18  
19  
5 psi  
60  
63  
112  
168  
168  
189  
210  
187  
168.5  
253  
15  
15 psi  
30 psi  
60 psi  
100 psi  
150 psi  
90  
95  
45  
90  
95  
253  
90  
90  
100  
90  
95  
105  
95  
263.5  
295  
262.5  
180  
250  
250  
Note:  
1. Differential common mode pressure should not exceed 50 psi.  
Figure 1. Mounting Dimensions (For reference only: mm (in).)  
D/A Housing  
(Differential/Absolute)  
GFS/AFS Housing  
(Gage/Absolute Offset Axial)  
GBFS Housing  
(Gage Backside Offset Axial)  
2
www.honeywell.com/sensing  
Compensated/Calibrated and Uncompensated/  
Uncalibrated Board Mount Pressure Sensors  
Figure 1. Mounting Dimensions (continued)  
GF/AF Housing  
(Gage/Absolute Axial)  
DF Housing  
(Differential Axial)  
GBF Housing  
(Gage Backside Axial)  
GT/AT Housing  
(Gage/Absolute Radial)  
GBT Housing  
(Gage Backside Radial)  
DT Housing  
(Differential Radial)  
Honeywell Sensing and Control  
3
Figure 2. Equivalent Circuit  
Pinout  
Media compatibility: Clean, dry gases only.  
1. -V Excitation  
P1 Port: Media must be compatible with epoxy-based adhesive and silicon gel.  
P2 Port: Media must be compatible with nylon housing, epoxy-based adhesive and  
silicon.  
2. + Output Signal  
3. +V Excitation  
4. - Output Signal  
Order Guide1  
XPCL  
04  
G
B
F
C
Series  
Accuracy Grade  
(XPC, XPCL only)  
C - Commercial  
XPC - compensated and calibrated (psi)  
XPCL - compensated and calibrated (inH20)  
XPXL - uncompensated and uncalibrated (inH20)  
H - High Accuracy  
Pressure Range  
04 inH20, 10 inH20  
01, 05, 15, 30, 60, 100, 150 psi  
Pressure Reference  
G - Gage  
D - Differential  
Port Option  
F - Axial  
Port Operation2  
T - Radial  
A - Absolute > 5 psi  
B - Backside  
FS - Offset Axial2  
Notes:  
1. Not all combinations may be available. Contact Honeywell representative for details.  
2. Option available in ported gage version only.  
WARNING  
WARNING  
MISUSE OF DOCUMENTATION  
PERSONAL INJURY  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
Failure to comply with these instructions could result in  
death or serious injury.  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
WARRANTY/REMEDY  
Failure to comply with these instructions could result in  
death or serious injury.  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
SALES AND SERVICE  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer’s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
Phone and Fax:  
Asia Pacific +65 6355-2828  
+65 6445-3033 Fax  
Europe  
+44 (0) 1698 481481  
+44 (0) 1698 481676 Fax  
Latin America +1-305-805-8188  
+1-305-883-8257 Fax  
USA/Canada +1-800-537-6945  
+1-815-235-6847  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
+1-815-235-6545 Fax  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
008046-6-EN IL50 GLO Printed in USA  
July 2011  
© 2011 Honeywell International Inc. All rights reserved.  
Golden Valley, MN 55422  
www.honeywell.com/sensing  

相关型号:

XPC01DH

Precision compensated pressure sensors / mV-output
SENSORTECHNIC

XPC01DH

Peizoresistive Sensor, Gage, -1Psi Min, 1Psi Max, Through Hole Mount
HONEYWELL

XPC01DTC

Precision compensated pressure sensors / mV-output
SENSORTECHNIC

XPC01DTC

Peizoresistive Sensor, Differential, 0Psi Min, 1Psi Max, 0-18mV, Through Hole Mount
HONEYWELL

XPC01DTH

Precision compensated pressure sensors / mV-output
SENSORTECHNIC

XPC01DTH

Peizoresistive Sensor, Differential, 17-19mV, Panel Mount, Through Hole Mount
HONEYWELL

XPC01GBFC

Peizoresistive Sensor, Gage, 0Psi Min, 1Psi Max, 0-18mV, Through Hole Mount
HONEYWELL

XPC01GBFH

Peizoresistive Sensor, Gage, 0Psi Min, 1Psi Max, 0-18mV, Through Hole Mount
HONEYWELL

XPC01GBFSH

Peizoresistive Sensor, Gage, 0Psi Min, 1Psi Max, 0-18mV, Through Hole Mount
HONEYWELL

XPC01GBTC

Peizoresistive Sensor, Gage, 0Psi Min, 1Psi Max, 0-18mV, Through Hole Mount
HONEYWELL

XPC01GC

Peizoresistive Sensor, Gage, 0Psi Min, 1Psi Max, 0-18mV, Through Hole Mount
HONEYWELL

XPC01GFC

暂无描述
HONEYWELL