XPX05ABFH [HONEYWELL]

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 0-168.5mV, Through Hole Mount;
XPX05ABFH
型号: XPX05ABFH
厂家: Honeywell    Honeywell
描述:

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 0-168.5mV, Through Hole Mount

传感器 换能器
文件: 总4页 (文件大小:159K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
XPC/XPCL and XPX/XPXL  
Series  
Uncompensated/Compensated and  
Compensated Calibrated Silicon  
Pressure Sensors  
DESCRIPTION  
On devices of 5 psi and above, the top side of the chip is  
The XPC/XPCL and XPX/XPXL Series sensors integrate  
silicon micromachined sensing technology, temperature  
compensation, and calibration in a complete family of low-cost  
packages. This series offers a cost-effective solution for design  
requirements.  
protected against humidity by a Silgel® coating.  
Although the sensors are designed for use with noncorrosive,  
nonionic pressure media, they accommodate many gases that  
are used in medical applications.  
These piezoresistive pressure sensors use micromachined  
silicon chips mounted on ceramic and protected with a plastic  
cap. Several tube arrangements with nylon housings are  
available for various pressure applications.  
FEATURES  
POTENTIAL APPLICATIONS  
Low cost, small size  
Medical applications  
Temperature compensated  
Zero and span calibrated  
Millivolt output  
Applications requiring small size  
Applications requiring vacuum and positive pressure  
reference or both  
Differential, gage and absolute pressure  
Constant voltage excitation  
High impedance - low current  
XPC/XPCL and XPX/XPXL Series  
ELECTRICAL SPECIFICATIONS  
Characteristic  
XPC/XPCL at 12 Vdc, 25 °C [77 °F]  
XPX/XPXL at 5 Vdc, 25 °C [77 °F]  
Min.  
Typ.  
Max.  
Unit  
Unit  
Min.  
3.0  
-50  
Typ.  
5.0  
0
Max.  
12.0  
50  
Excitation voltage  
Null  
3.0  
-1.0  
12.0  
0
16.0  
1.0  
±1.0  
Vdc  
mV  
Vdc  
mV  
mV  
Offset temperature shift(1)  
0 °C to 25 °C [32 °F to 77°F]  
25 °C to 70 °C [77 °F to 158 °F]  
Full scale temperature shift(1)  
0 °C to 25 °C [32 °F to 158 °F]  
25 °C to 70 °C [77 °F to 158 °F]  
Linearity, hysteresis error(2)  
Input resistance  
±0.5  
mV  
±2  
PPM/°C  
-2200  
PPM/°C  
5.0  
0.25  
3.0  
1.0  
85 [185]  
125 [257]  
50  
% span  
kOhm  
kOhm  
°C [°F]  
°C [°F]  
psi  
0.25  
3.0  
1.0  
85 [185]  
125 [257]  
50  
% span  
kOhm  
kOhm  
°C [°F]  
°C [°F]  
psi  
5.0  
Output resistance  
Operating temperature  
Storage temperature  
Common mode pressure  
Weight  
-25 [-13]  
-40 [-40]  
-25 [-13]  
-40 [-40]  
2
g
2
g
Notes:  
1. Shift is relative to 25 °C [77 °F].  
2. Measured at 1/2 full scale rated pressure using BFSL.  
ABSOLUTE OUTPUT  
FS Pressure  
XPC at 12 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
XPX at 5 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
Overpressure  
(psi)  
Max.  
15  
45  
90  
180  
250  
Min.  
Typ.  
60  
Max.  
Min.  
Typ.  
168.5  
253  
Max.  
225  
338  
338  
338  
380  
5 psi  
57  
85  
85  
85  
95  
63  
95  
95  
95  
105  
112  
168  
168  
189  
210  
15 psi  
30 psi  
60 psi  
100 psi  
90  
90  
90  
100  
253  
263.5  
295  
GAGE/DIFFERENTIAL(1) OUTPUT  
FS Pressure  
XPC/XPCL at 12 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
XPX/XPXL at 5 Vdc, 25 °C [77 °F]  
Output Full Scale Span (mV)  
Overpressure  
(psi)  
Max.  
3
3
3
15  
45  
90  
Min.  
Typ.  
25  
Max.  
Min.  
50  
Typ.  
68  
Max.  
86  
4 in H2O  
10 in H2O  
1 psi  
5 psi  
15 psi  
30 psi  
60 psi  
100 psi  
150 psi  
23  
19  
17  
57  
85  
85  
85  
95  
85  
27  
21  
19  
63  
95  
95  
95  
105  
95  
20  
18  
60  
90  
90  
90  
100  
90  
40  
40  
78.5  
75  
168.5  
253  
253  
263.5  
112  
110  
225  
338  
338  
338  
380  
338  
112  
168  
168  
189  
210  
187  
180  
250  
250  
295  
262.5  
Note:  
1. Differential common mode pressure should not exceed 50 psi.  
MOUNTING DIMENSIONS (For reference only: mm (in).)  
D/A Housing  
(Differential/Absolute)  
GFS/AFS Housing  
(Gage/Absolute Offset Axial)  
GBFS Housing  
(Gage Backside Offset Axial)  
2
www.honeywell.com/sensing  
Uncompensated/Compensated and Compensated Calibrated  
Silicon Pressure Sensors  
MOUNTING DIMENSIONS (For reference only: mm (in).)  
GF/AF Housing  
(Gage/Absolute Axial)  
DF Housing  
(Differential Axial)  
GBF Housing  
(Gage Backside Axial)  
GT/AT Housing  
(Gage/Absolute Radial)  
GBT Housing  
(Gage Backside Radial)  
DT Housing  
(Differential Radial)  
Honeywell Sensing and Control  
3
EQUIVALENT CIRCUIT  
Pinout  
Media compatibility: Clean, dry gases only.  
1. -V Excitation  
2. + Output Signal  
3. +V Excitation  
4. - Output Signal  
P1 Port: Media must be compatible with epoxy-based adhesive and silicon gel.  
P2 Port: Media must be compatible with nylon housing, epoxy-based adhesive and  
silicon.  
ORDER GUIDE(1)  
Notes:  
1. Not all combinations may be available. Contact Honeywell representative for details.  
2. Option available in ported gage version only.  
WARNING  
WARNING  
PERSONAL INJURY  
MISUSE OF DOCUMENTATION  
DO NOT USE these products as safety or emergency stop  
devices or in any other application where failure of the  
product could result in personal injury.  
The information presented in this product sheet is for  
reference only. Do not use this document as a product  
installation guide.  
Failure to comply with these instructions could result in  
death or serious injury.  
Complete installation, operation, and maintenance  
information is provided in the instructions supplied with  
each product.  
Failure to comply with these instructions could result in  
death or serious injury.  
WARRANTY/REMEDY  
Honeywell warrants goods of its manufacture as being free of  
defective materials and faulty workmanship. Honeywell’s  
standard product warranty applies unless agreed to otherwise  
by Honeywell in writing; please refer to your order  
acknowledgement or consult your local sales office for specific  
warranty details. If warranted goods are returned to Honeywell  
during the period of coverage, Honeywell will repair or replace,  
at its option, without charge those items it finds defective. The  
foregoing is buyer’s sole remedy and is in lieu of all other  
warranties, expressed or implied, including those of  
merchantability and fitness for a particular purpose. In no  
event shall Honeywell be liable for consequential, special,  
or indirect damages.  
SALES AND SERVICE  
Honeywell serves its customers through a worldwide network  
of sales offices, representatives and distributors. For  
application assistance, current specifications, pricing or name  
of the nearest Authorized Distributor, contact your local sales  
office or:  
E-mail: info.sc@honeywell.com  
Internet: www.honeywell.com/sensing  
Phone and Fax:  
Asia Pacific +65 6355-2828  
While we provide application assistance personally, through  
our literature and the Honeywell web site, it is up to the  
customer to determine the suitability of the product in the  
application.  
+65 6445-3033 Fax  
Europe  
+44 (0) 1698 481481  
+44 (0) 1698 481676 Fax  
Latin America +1-305-805-8188  
+1-305-883-8257 Fax  
USA/Canada +1-800-537-6945  
+1-815-235-6847  
Specifications may change without notice. The information we  
supply is believed to be accurate and reliable as of this  
printing. However, we assume no responsibility for its use.  
+1-815-235-6545 Fax  
Sensing and Control  
Honeywell  
1985 Douglas Drive North  
008046-5-EN IL50 GLO Printed in USA  
July 2007  
© 2007 Honeywell International Inc. All rights reserved.  
Minneapolis, MN 55422  
www.honeywell.com/sensing  

相关型号:

XPX05ABTC

暂无描述
HONEYWELL

XPX05ABTH

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 0-168.5mV, Through Hole Mount
HONEYWELL

XPX05AC

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 0-630mV, Round, Through Hole Mount
HONEYWELL

XPX05AFC

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 0-630mV, Through Hole Mount
HONEYWELL

XPX05ATC

Peizoresistive Sensor, Absolute, 0Psi Min, 5Psi Max, 0-630mV, Through Hole Mount
HONEYWELL

XPX05DBFC

Peizoresistive Sensor, Differential, 0Psi Min, 5Psi Max, 0-253mV, Through Hole Mount
HONEYWELL

XPX05DC

Pressure Sensor, DIFFERENTIAL, PEIZORESISTIVE PRESSURE SENSOR, 0-5Psi, 0-630mV, ROUND, THROUGH HOLE MOUNT
HONEYWELL

XPX05DFC

Peizoresistive Sensor, Differential, 0Psi Min, 5Psi Max, 0-630mV, Through Hole Mount
HONEYWELL

XPX05GBFC

Peizoresistive Sensor, Gage, 0Psi Min, 5Psi Max, 0-630mV, Through Hole Mount
HONEYWELL

XPX05GBFH

Peizoresistive Sensor, Gage, 0Psi Min, 5Psi Max, 0-253mV, Through Hole Mount
HONEYWELL

XPX05GBFSC

Peizoresistive Sensor, Gage, 0Psi Min, 5Psi Max, 0-630mV, Through Hole Mount
HONEYWELL

XPX05GBFSH

Peizoresistive Sensor, Gage, 0Psi Min, 5Psi Max, 0-253mV, Through Hole Mount
HONEYWELL