401425 [HP]

Real-Time PCR System;
401425
型号: 401425
厂家: HEWLETT-PACKARD    HEWLETT-PACKARD
描述:

Real-Time PCR System

PC
文件: 总2页 (文件大小:308K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AriaDx  
Real-Time PCR System  
For In Vitro Diagnostic Use  
Total Confidence qPCR  
Specifications Table  
The AriaDx Real-Time PCR System is a fully  
integrated quantitative PCR amplification,  
detection, and data analysis system. Now  
with innovative modular optics which can be  
changed out in one easy step, the instrument  
provides the flexibility to scale up over time,  
as needed.  
Feature  
Description  
Excitation Source  
Detection Sources  
Optical Cartridges  
8 dye specific LEDs per optical module  
8 photodiodes  
SYBR/FAM  
HEX  
ROX  
CY3  
CY5  
ATTO425  
6 slots, swappable optical modules  
The latest design combines a state-of-the-art  
thermal cycler, an advanced optical system  
with LED excitation source, and data analysis  
software. Continuing the tradition of intuitive  
software, the instrument now has a  
touchscreen, so plates and analytics can  
be started with the touch of a finger.  
Dye Selection  
Excitation and Emission  
Reaction Volume  
Chemistries Supported  
Thermal System  
10 μl to 30 μl  
SYBR and Probes  
Six Peltiers made from two ceramic plates with semi-conductor elements, 96-well  
Thermal System  
Temperature Range  
25.0 – 99.9°C  
Heating: 6.0°C/sec  
Cooling: 3.0°C/sec (Median), 2.5°C/sec (Average)  
Accuracy: ± 0.2°C or better at typical annealing, amplification, and denaturation  
temperatures  
With enhanced performance, the software  
provides results capturing RDML information  
required for publishing under the miQE  
guidelines. Simultaneously, the software is  
equipped to export images and raw data  
in multiple formats, allowing results to be  
viewed in common programs.  
Dynamic Range  
9
Experiment Types  
Quantitative PCR with dye, Quantitative PCR with probe, Allele Discrimination with  
probe, Comparative Quantitation, User Defined  
Uniformity  
± 0.4°C  
Data Acquisition Time  
Cq Uniformity  
<3 seconds for all  
Cq St Dev <0.20 at fast cycling (5s 95°C/10s 60°C)  
100 – 240VAC, 50/60Hz, 1100VA  
20 – 30°C, 20 – 80% non-condensing humidity, 7500 feet, max altitude  
50 lbs. (23 kg)  
Electrical Power (input)  
Operating Environment  
Weight  
For more firmware and software features, see next page.  
Dimensions  
19.7” W x 18.1“ D x 16.5” H (50cm x 46cm x 42cm)  
96-well plates, strip tubes; 0.2mL tubes  
Sample Containers  
Warranty  
• 1 year warranty is standard with the instrument  
• 5 year warranty and service packages available  
• Thermal, physical, interactive (sensors) tests  
• Extended: 125 performance points tested in 30 minutes  
• Start-up: 59 performance points tested in ~1 minute  
• Optional bypass of both features  
Onboard Analytics  
Services (upon request) • Installation & Familiarization  
• Diagnostic Preventative Maintenance  
• Additional service contract to extend warranty coverage up to 5 years  
• Return-to-Agilent Instrument Exchange Program  
• Thermal block verification  
Specifications Table continued  
Feature  
Description  
Operating System  
• Windows 7 and 10  
Run Modes  
• Stand alone  
• PC connected  
• LAN connected to PC (more than 20 instruments can be connected and monitored remotely)  
• USB connected, external devices  
Software  
Free software including LIMS connectivity feature  
Optical Module Calibration  
and Cleaning  
• All channels can be tested and calibrated  
• All attributes of optical channels are calibrated at the factory – LED light output, light path, mirror, and photodiode  
• Optical modules can be cleaned in lab without Agilent technician or sending back to factory  
Selected Applications  
• Quantitative and qualitative gene expression analysis  
• miRNA analysis  
• Genetic mapping  
• NGS library quantification  
• 2-6 channel multiplex ability  
• Pathogen quantification  
• Genetic fingerprinting  
Ordering Information  
Category  
Part #  
Description  
Quantity  
Instrumentation  
K8930AA  
AriaDx Real-Time PCR instrument  
SYBR/FAM Optical Cartridge  
ROX Optical Cartridge  
1
Option 101  
Option 102  
Option 103  
Option 104  
Option 105  
Option 106  
1/pack  
1/pack  
1/pack  
1/pack  
1/pack  
1/pack  
HEX Optical Cartridge  
CY3 Optical Cartridge  
CY5 Optical Cartridge  
ATTO425 Optical Cartridge  
Option 300  
Option 650  
Electronic Tracking  
PC Kit  
1
1
AriaDx Software Upgrade  
(post instrument purchase)  
K5822AA  
Electronic Tracking of AriaDx Software (Upgrade)  
1
Optical Cartridges  
(sold without instrument)  
G8830-67001  
G8830-67002  
G8830-67003  
G8830-67004  
G8830-67005  
G8830-67006  
401490  
SYBR/FAM Optical Cartridge  
ROX Optical Cartridge  
1/pack  
1/pack  
HEX Optical Cartridge  
1/pack  
CY3 Optical Cartridge  
1/pack  
CY5 Optical Cartridge  
1/pack  
ATTO425 Optical Cartridge  
1/pack  
Plastics  
96-well plates, skirted and low profile  
96-well plates, skirted and rigid  
96-well plates, non skirted low profile  
Adhesive plate seals  
1 x 25/pack  
1 x 25/pack  
1 x 25/pack  
1 x 25 plates  
8/strip x 120/box  
8/strip x 120/box  
Box of 60  
401491  
401494  
401492  
401493  
Low profile strip tubes for PCR and qPCR applications, without caps  
Strip caps for PCR and qPCR applications  
Optical Strip Caps  
401425  
401427  
Reagents  
SYBR  
5190-7708  
SYBR Qualification Plate  
1 plate/pack  
www.agilent.com/genomics/ariadxsoftware  
For In Vitro Diagnostic Use  
PR7000-0181  
© Agilent Technologies, Inc., 2018  
Published in USA, March 5, 2018  
5991-6877EN  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY