P-AT-826.5-70A [HRS]

Programmable Attenuators; 可编程衰减器
P-AT-826.5-70A
型号: P-AT-826.5-70A
厂家: HRS    HRS
描述:

Programmable Attenuators
可编程衰减器

衰减器
文件: 总5页 (文件大小:97K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Programmable Attenuators  
P-AT Series  
Features  
1.Used for frequencies from DC to 26.5GHz (max.)  
Input/output couplings utilizes Hirose’s HE*  
connector, which is combination of the internal  
attenuation elements, provides the required  
attenuation characteristic.  
2.Self-disconnecting  
The drive current will automatically switch off after  
setting the attenuation.  
3.Automatic return  
In the event of sudden shock the attenuation will  
quickly return to the pre-set level.  
Applications  
Wide variety of measuring instruments and other  
devices requiring control of high frequency  
transmission lines.  
* HE connector will mate with K type connectors  
* K connector is a trademark of Anritsu Co.  
Product Specifications  
Operating temperate range  
Operating relative humidity  
DC~8GHz(P-AT-6,AP-AT-7)  
DC~26.5GHz(P-AT-8)  
-10ç to +75ç(No freezing)  
95% Max.  
Frequency range  
Ratings  
Characteristic  
1.Vibration  
Requirements  
Conditions  
Frequency of 10 to 55 Hz, overall amplitude of 1.5  
mm for 2 hours in each of 3 directions  
No electrical discontinuity of 1 µs or more  
2
No damage, cracks, or parts dislocation  
Acceleration of 98 m/s , sine half-wave waveform,  
2.Shock  
3 cycles in each of the 3 axis  
3.Temperature cycle  
No damage, cracks, or parts dislocation  
The test method conforms to MIL-STD-202.  
Materials and Finishes  
Ordering Information  
Component  
Body  
Material  
Aluminum  
Finish  
Conductive alumite  
Passivated  
P-AT - 6 ( 8 - 70 ) A  
1
2
3
4
5
Coupling connector body  
Female contact  
Stainless steel  
Beryllium Copper  
Series Name  
Suffix  
1
2
3
4
5
Gold plating  
Maximum frequency (GHz)  
Maximum attenuation (dB)  
Revised  
102  
Specifications  
Insertion  
Attenuation Accuracy  
Switching  
Current  
(Each Section)  
(mA)  
Frequency  
Range  
(GHz)  
Switching  
Volt  
(DC V)  
Switching  
Time  
(ms)(Max)  
V.S.W.R. Attenuation  
Loss Impedance Power  
(dB) (ohms) (W)  
(Max)  
Operating Connectors Weight  
(dB)  
Part Number  
(Max)  
(dB)  
Life  
(g)  
5dB 10dB 20dB 40dB  
0~70  
(10dB  
STEP)  
0~75  
(5dB  
120+200  
∞3  
6
6
P-AT-6(8-70)A  
P-AT-7(8-75)A  
DC  
DC  
~
8
8
1.35  
1.35  
---  
0.5 0.6  
1
1
1.5  
1.5  
50  
50  
1(CW) +24  
1(CW) +24  
20  
20  
2∞10  
2∞10  
HE-J  
HE-J  
250  
300  
section  
160+200  
∞4  
section  
~
0.5 0.5 0.6  
STEP)  
1.4  
(DC~  
12GHz)  
1.7  
0~70  
120+200  
∞3  
section  
0.55+  
0.06∞f(GHz)  
6
P-AT-8(26.5-70)A DC  
~
26.5  
(10dB --- Ref table 1  
STEP)  
50  
1(CW) +24  
20  
2∞10  
HE-J  
240  
(12~  
26.5GHz)  
Attenuation Accuracy(dB)  
Frequency Range  
GHz)  
10dB 20dB 30dB 40dB 50dB 60dB 70dB  
DC~8  
8~12  
0.3 0.5 0.6 0.7 0.8 1.0 1.1  
0.4 0.5 0.7 0.9 1.0 1.3 1.5  
0.5 0.6 0.8 1.1 1.2 1.4 1.7  
0.7 0.8 1.0 1.5 1.6 1.9 2.3  
12~20  
20~26.5  
Typical Data  
P-AT-7(8-75)A  
[dB]  
Attenuation  
75  
70  
65  
60  
55  
50  
45  
40  
35  
30  
25  
20  
15  
10  
[dB]  
2.0  
Insertion Loss  
1.0  
0
VSW R  
1.35  
1.30  
スルー(0dB)  
1.20  
1.10  
1.00  
DC  
2
4
6
8
5
0
FrequencyGHz〕  
DC  
2
4
6
8
FrequencyGHz〕  
103  
External Dimensions  
340  
Control connector  
HIF3BA-10D-2.54R  
117  
10-conductor flat ribbon cable  
9.55  
97.9  
9.55  
2-M3∞0.5  
4mm deep  
Opposite side is the same  
2-1/4-36UNS-2A  
RF IN  
RF OUT  
Circuit Organization  
(23.15)  
51.6  
(23.15)  
Opposite side is the same  
Section Number  
RF IN  
1
2
3
Through  
RF OUT  
10dB  
40dB  
20dB  
250  
Control connector  
HIF3BA-10D-2.54R  
10-conductor flat ribbon cable  
142.8  
123.7  
9.55  
9.55  
2-M3∞0.5  
4mm deep  
Opposite side is the same  
RF IN  
RF OUT  
(23.15)  
2-1/4-36UNS-2A  
(23.15)  
77.4  
Circuit Organization  
Opposite side is the same  
Section Number  
RF IN  
1
2
3
4
Through  
RF OUT  
10dB  
40dB  
20dB  
5dB  
104  
External Dimensions  
P-AT-8(26.5-70)A  
250  
Control connector  
HIF2B-14-2.54RB  
10-conductor flat ribbon cable  
90.2  
2-1/4-36UNS-2A  
76.2  
RF IN  
RF OUT  
2-M3∞0.5  
105.9  
6mm deep  
Opposite side is the same  
Circuit Organization  
Section Number  
RF IN  
1
2
3
Through  
RF OUT  
10dB  
40dB  
20dB  
105  
K
K
HIF3BA-10D-2.54R ContactNo.  
P-AT-6(8-70)A,P-AT-7(8-75)A  
HIF2B-14-2.54RB Contact No.  
P-AT-8(26.5-70)A  
1
7
8
1
3
7
8
9
5
2
4
6
10  
14  
BAttenuation Change Contact No.(Connect Ground)  
Section No.  
1
2
3
4
Contact  
No.  
Contact  
No.  
Contact  
No.  
Contact  
No.  
Cable Color Attenuation  
Cable Color Attenuation  
Cable Color Attenuation  
Cable Color Attenuation  
Part No.  
1
2
Black  
White  
Black  
White  
Black  
White  
0dB(Through)  
10dB  
3
4
3
4
3
9
Gray  
Purple  
Gray  
0dB(Through)  
40dB  
5
6
Blue  
Green  
Blue  
0dB(Through)  
20dB  
----  
----  
7
----  
----  
----  
----  
P-AT-6(8-70)A  
1
0dB(Through)  
10dB  
0dB(Through)  
40dB  
5
0dB(Through)  
20dB  
Yellow 0dB(Through)  
P-AT-7(8-75)A  
2
Purple  
Gray  
6
Green  
Green  
Yellow  
8
Orange  
----  
5dB  
----  
13  
2
0dB(Through)  
10dB  
0dB(Through)  
40dB  
11  
5
0dB(Through)  
20dB  
----  
----  
P-AT-8(26.5-70)A  
Brown  
----  
----  
BDrive Voltage Contact No.  
Section No.  
DC24V  
Ground  
Open  
Contact  
Contact  
Contact  
No.  
Cable Color  
Red  
Cable Color  
Yellow  
Orange  
----  
Cable Color  
----  
Part No.  
No.  
No.  
9
7
----  
----  
P-AT-6(8-70)A  
10  
9
Brown  
Red  
8
Connector Body  
----  
----  
----  
----  
P-AT-7(8-75)A  
10  
6
Brown  
Red  
----  
----  
----  
12  
Purple  
----  
4
Blue  
Orange  
----  
P-AT-8(26.5-70)A  
----  
----  
----  
----  
10  
----  
----  
----  
1,7,8,14  
K
DC Drive Circuit (1 Section)  
Switching signal to  
the RF through side (0 dB)  
Solenoid  
Drive circuit  
+24V  
Automatic return and  
automatic disconnection  
by photo sensor  
Switching signal to  
the RF resistance side  
106  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY