3.3V PROGRAMMABLE  
SKEW PLL CLOCK DRIVER  
TURBOCLOCK™  
QS5V991  
FEATURES/BENEFITS  
DESCRIPTION  
REFis 5Vtolerant  
TheQS5V991is ahighfanout3.3VPLLbasedclockdriverintendedfor  
highperformancecomputinganddata-communicationsapplications.Akey  
featureoftheprogrammableskewistheabilityofoutputstoleadorlagthe  
REFinputsignal.TheQS5V991has eightprogrammableskewoutputs in  
fourbanksof2.Skewiscontrolledby3-levelinputsignalsthatmaybehard-  
wiredtoappropriate HIGH-MID-LOW levels.  
4pairs ofprogrammable skewoutputs  
Low skew: 200ps same pair, 250ps all outputs  
Selectable positive ornegative edge synchronization:  
ExcellentforDSPapplications  
Synchronous outputenable  
Outputfrequency: 6.25MHzto85MHz  
2x, 4x, 1/2, and 1/4 outputs  
3 skew grades:  
Whenthe GND/sOE pinis heldlow,allthe outputs are synchronously  
enabled.However,ifGND/sOEisheldhigh,alltheoutputsexcept3Q0and  
3Q1 are synchronously disabled.  
QS5V991-2:tSKEW0<250ps  
QS5V991-5:tSKEW0<500ps  
QS5V991-7:tSKEW0<750ps  
3-level inputs for skew and PLL range control  
PLL bypass for DC testing  
Externalfeedback,internalloopfilter  
12mAbalanceddrive outputs  
Furthermore, when the VCCQ/PE is held high, all the outputs are  
synchronizedwiththe positive edge ofthe REFclockinput.WhenVCCQ/  
PEis heldlow,allthe outputs are synchronizedwiththe negative edge of  
REF. BothdeviceshaveLVTTLoutputswith12mAbalanceddriveoutputs.  
LowJitter: <200ps peak-to-peak  
Industrialtemperaturerange  
Available in 32-pin PLCC Package  
FUNCTIONALBLOCKDIAGRAM  
GND/sOE  
1Q0  
Skew  
Select  
1Q1  
3
3
3
1F1:0  
VCCQ/PE  
2Q0  
2Q1  
Skew  
Select  
3
REF  
PLL  
2F1:0  
FB  
3Q0  
3Q1  
Skew  
Select  
3
3
3
3
FS  
3F1:0  
4Q0  
4Q1  
Skew  
Select  
3
4F1:0  
COMMERCIAL/INDUSTRIAL TEMPERATURE RANGES  
MAY 2000  
1
c
2000 Integrated Device Technology, Inc.  
DSC-5786/-  
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
ABSOLUTE MAXIMUM RATINGS (1)  
PINCONFIGURATION  
Symbol  
Rating  
Max.  
Unit  
Supply Voltage to Ground  
–0.5 to +7  
V
VI  
DC Input Voltage  
–0.5 to VCC+0.5  
–0.5 to +5.5  
0.8  
V
V
REF Input Voltage  
4
3
2
1
32 31 30  
3F1  
4F0  
5
29  
28  
27  
26  
25  
24  
23  
22  
21  
2F0  
Maximum Power Dissipation (TA = 85°C)  
Storage Temperature Range  
W
6
GND/sOE  
1F1  
TSTG  
–65°C to +150°C °C  
4F1  
7
NOTE:  
1. Stresses greater than those listed under ABSOLUTE MAXIMUM  
RATINGS may cause permanent damage to the device. This is a  
stress rating only and functional operation of the device at these or  
any other conditions above those indicated in the operational sections  
of this specification is not implied. Exposure to absolute maximum  
rating conditions for extended periods may affect reliability.  
VCCQ/PE  
8
1F0  
J32-1  
VCCN  
VCCN  
4Q1  
9
10  
11  
12  
13  
1Q0  
4Q0  
1Q1  
GND  
GND  
GND  
GND  
CAPACITANCE (T = 25 C, f = 1MHz, V = 0V)  
°
A
IN  
14 15 16 17 18 19 20  
Parameter  
Description  
Typ.  
Max.  
Unit  
CIN  
Input Capacitance  
5
7
pF  
NOTE:  
PLCC  
1. Capacitance applies to all inputs except TEST, FS, and nF1:0.  
TOP VIEW  
PIN DESCRIPTION  
Pin Name  
Type  
Description  
REF  
IN  
Reference Clock Input  
Feedback Input  
FB  
IN  
TEST (1)  
IN  
When MID or HIGH, disables PLL (except for conditions of Note 1). REF goes to all outputs. Skew selections (see Control  
Summary Table) remain in effect. Set LOW for normal operation.  
GND/ sOE (1)  
IN  
IN  
Synchronous Output Enable. When HIGH, it stops clock outputs (except 3Q0 and 3Q1) in a LOW state - 3Q0 and 3Q1 may be used  
as the feedback signal to maintain phase lock. When TEST is held at MID level and GND/sOE is HIGH, the nF[1:0] pins act as  
output disable controls for individual banks when nF[1:0] = LL. Set GND/sOE LOW for normal operation.  
Selectable positive or negative edge control. When LOW/HIGH the outputs are synchronized with the negative/positive edge of the  
reference clock.  
VCCQ/PE  
nF[1:0]  
FS  
IN  
3-level inputs for selecting 1 of 9 skew taps or frequency functions  
IN  
Selects appropriate oscillator circuit based on anticipated frequency range. (See PLL Programmable Skew Range.)  
nQ[1:0]  
VCCN  
VCCQ  
GND  
OUT  
PWR  
PWR  
PWR  
Four banks of two outputs with programmable skew  
Power supply for output buffers  
Power supply for phase locked loop and other internal circuitry  
Ground  
NOTE:  
1. When TEST = MID and GND/sOE = HIGH, PLL remains active with nF[1:0] = LL functioning as an output disable control for individual output banks.  
Skew selections remain in effect unless nF[1:0] = LL.  
PROGRAMMABLESKEW  
Output skew with respect to the REF input is adjustable to compensate to minimize the number of control pins, 3-level inputs (HIGH-MID-LOW)  
for PCB trace delays, backplane propagation delays or to accommodate are used, they are intended for but not restricted to hard-wiring. Undriven  
requirements for special timing relationships between clocked compo- 3-level inputs default to the MID level. Where programmable skew is  
nents. Skew is selectable as a multiple of a time unit tU which is of the not a requirement, the control pins can be left open for the zero skew  
order of a nanosecond (see PLL Programmable Skew Range and Resolution default setting. The Control Summary Table shows how to select specific  
Table). There are nine skew configurations available for each output skew taps by using the nF1:0 control pins.  
pair. These configurations are chosen by the nF1:0 control pins. In order  
2
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
EXTERNALFEEDBACK  
By providing external feedback, the QS5V991 gives users flexibility  
with regard to skew adjustment. The FB signal is compared with the  
input REF signal at the phase detector in order to drive the VCO. Phase  
differences cause the VCO of the PLL to adjust upwards or downwards  
accordingly.  
An internal loop filter moderates the response of the VCO to the  
phase detector. The loop filter transfer function has been chosen to  
provide minimal jitter (or frequency variation) while still providing accu-  
rate responses to input frequency changes.  
PLL PROGRAMMABLE SKEW RANGE AND RESOLUTION TABLE  
FS = LOW  
1/(44 x FNOM)  
25 to 35MHz  
FS = MID  
1/(26 x FNOM)  
35 to 60MHz  
FS = HIGH  
1/(16 x FNOM)  
60 to 85 MHz  
Comments  
Timing Unit Calculation (tU)  
VCO Frequency Range (FNOM) (1,2)  
Skew Adjustment Range (3)  
Max Adjustment:  
±9.09ns  
±49º  
±9.23ns  
±83º  
±9.38ns  
±135º  
±37%  
ns  
Phase Degrees  
% of Cycle Time  
±14%  
tU = 0.91ns  
tU = 0.76ns  
±23%  
Example 1, FNOM = 25MHz  
Example 2, FNOM = 30MHz  
Example 3, FNOM = 40MHz  
Example 4, FNOM = 50MHz  
Example 5, FNOM = 80MHz  
tU = 0.96ns  
tU = 0.77ns  
tU = 0.78ns  
NOTES:  
1. The device may be operated outside recommended frequency ranges without damage, but functional operation is not guaranteed. Selecting the ap-  
propriate FS value based on input frequency range allows the PLL to operate in its ‘sweet spot’ where jitter is lowest.  
2. The level to be set on FS is determined by the nominal operating frequency of the VCO and Time Unit Generator. The VCO frequency always ap-  
pears at 1Q1:0, 2Q1:0, and the higher outputs when they are operated in their undivided modes. The frequency appearing at the REF and FB inputs will  
be the same as the VCO when the output connected to FB is undivided. The frequency of the REF and FB inputs will be 1/2 or 1/4 the VCO frequency  
when the part is configured for a frequency multiplication by using a divided output as the FB input.  
3. Skew adjustment range assumes that a zero skew output is used for feedback. If a skewed Q output is used for feedback, then adjustment range will  
be greater. For example if a 4tU skewed output is used for feedback, all other outputs will be skewed –4tU in addition to whatever skew value is programmed  
for those outputs. ‘Max adjustment’ range applies to output pairs 3 and 4 where ± 6tU skew adjustment is possible and at the lowest FNOM value.  
4. The maximum REF Clock Input Frequency is 70MHz. Use Q/2 or Q/4 as feedback and use the Control Summary Table explicitly for output frequency  
to 85MHz.  
CONTROL SUMMARY TABLE FOR FEEDBACK SIGNALS  
nF1:0  
LL (1)  
LM  
Skew (Pair #1, #2)  
Skew (Pair #3)  
Divide by 2  
–6tU  
Skew (Pair #4)  
Divide by 2  
–6tU  
–4tU  
–3tU  
LH  
–2tU  
–4tU  
–4tU  
ML  
–1tU  
–2tU  
–2tU  
MM  
MH  
HL  
Zero Skew  
1tU  
Zero Skew  
2tU  
Zero Skew  
2tU  
2tU  
4tU  
4tU  
HM  
HH  
3tU  
6tU  
6tU  
Inverted (2)  
4tU  
Divide by 4  
NOTES:  
1. LL disables outputs if TEST = MID and GND/sOE = HIGH.  
2. When pair #4 is set to HH (inverted), GND/ sOE disables pair #4 HIGH when VCCQ/PE = HIGH, GND/ sOE disables pair #4 LOW when VCCQ/PE =  
LOW.  
3
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
RECOMMENDED OPERATING RANGE  
QS5V991-5, -7  
(Industrial)  
QS5V991-2  
(Commercial)  
Symbol  
Description  
Power Supply Voltage  
Ambient Operating Temperature  
Min.  
Max.  
Min.  
Max.  
Unit  
Vcc  
3
3.6  
3
3.6  
V
TA  
-40  
+85  
0
+70  
°C  
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE  
Symbol  
Parameter  
Input HIGH Voltage  
Conditions  
Min.  
Max.  
Unit  
VIH  
Guaranteed Logic HIGH (REF, FB Inputs Only)  
2
V
V
VIL  
Input LOW Voltage  
Input HIGH Voltage (1)  
Input MID Voltage (1)  
Input LOW Voltage (1)  
Guaranteed Logic LOW (REF, FB Inputs Only)  
3-Level Inputs Only  
VCC0.6  
VCC/20.3  
0.8  
VIHH  
VIMM  
VILL  
IIN  
V
3-Level Inputs Only  
VCC/2+0.3  
0.6  
V
3-Level Inputs Only  
V
Input Leakage Current  
(REF, FB Inputs Only)  
VIN = VCC or GND  
VCC = Max.  
±5  
µA  
VIN = VCC  
HIGH Level  
MID Level  
LOW Level  
2.2  
±200  
±50  
I3  
3-Level Input DC Current (TEST, FS, nF1:0)  
VIN = VCC/2  
µA  
VIN = GND  
±200  
±100  
±100  
IPU  
Input Pull-Up Current (VCCQ/PE)  
Input Pull-Down Current (GND/sOE)  
Output HIGH Voltage  
VCC = Max., VIN = GND  
VCC = Max., VIN = VCC  
VCC = Min., IOH = 12mA  
VCC = Min., IOL = 12mA  
µA  
µA  
V
IPD  
VOH  
VOL  
Output LOW Voltage  
0.55  
V
NOTE:  
1. These inputs are normally wired to VCC, GND, or unconnected. Internal termination resistors bias unconnected inputs to VCC/2. If these inputs are  
switched, the function and timing of the outputs may be glitched, and the PLL may require an additional tLOCK time before all datasheet limits are  
achieved.  
POWER SUPPLY CHARACTERISTICS  
Symbol  
Parameter  
Test Conditions(1)  
VCC = Max., TEST = MID, REF = LOW,  
VCCQ/PE = LOW, GND/sOE = LOW  
All outputs unloaded  
Typ. (2)  
Max.  
Unit  
ICCQ  
Quiescent Power Supply Current  
8
25  
mA  
ICC  
ICCD  
ITOT  
Power Supply Current per Input HIGH  
Dynamic Power Supply Current per Output  
Total Power Supply Current  
VCC = Max., VIN = 3V  
1
30  
90  
µA  
µA/MHz  
mA  
VCC = Max., CL = 0pF  
55  
29  
42  
76  
VCC = 3.3V, FREF = 20MHz, CL = 160pF (1)  
VCC = 3.3V, FREF = 33MHz, CL = 160pF (1)  
VCC = 3.3V, FREF = 66MHz, CL = 160pF (1)  
mA  
mA  
NOTE:  
1. For eight outputs, each loaded with 20pF.  
4
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
INPUT TIMING REQUIREMENTS  
Symbol  
Description (1)  
Min.  
Max.  
Unit  
tR, tF  
Maximum input rise and fall times, 0.8V to 2V  
10  
ns/V  
tPWC  
DH  
Input clock pulse, HIGH or LOW  
Input duty cycle  
3
90  
70  
ns  
%
10  
10  
REF  
Reference Clock Input  
MHz  
NOTE:  
1. Where pulse width implied by DH is less than tPWC limit, tPWC limit applies.  
SWITCHING CHARACTERISTICS OVER OPERATING RANGE  
QS5V991-2  
Typ. Max.  
QS5V991-5  
Typ.  
QS5V991-7  
Typ.  
Symbol  
Parameter  
VCO Frequency Range  
Min.  
Min.  
Max.  
Min.  
Max.  
Unit  
FNOM  
See PLL Programmable Skew Range and Resolution Table  
tRPWH  
tRPWL  
tU  
REF Pulse Width HIGH (11)  
3
3
3
3
3
3
ns  
ns  
REF Pulse Width LOW (11)  
Programmable Skew Time Unit  
Zero Output Matched-Pair Skew (xQ0, xQ1) (1,2,3)  
Zero Output Skew (All Outputs) (1,4)  
See Control Summary Table  
tSKEWPR  
tSKEW0  
tSKEW1  
0.05  
0.1  
0.2  
0.25  
0.5  
0.1  
0.25  
0.6  
0.25  
0.5  
0.1  
0.3  
0.6  
0.25  
0.75  
1
ns  
ns  
ns  
Output Skew  
0.25  
0.7  
(Rise-Rise, Fall-Fall, Same Class Outputs) (1,5)  
tSKEW2  
tSKEW3  
tSKEW4  
Output Skew  
0.3  
0.25  
0.5  
1.2  
0.5  
0.9  
0.5  
0.5  
0.5  
1.2  
0.7  
1
1
1.5  
1.2  
1.7  
ns  
ns  
ns  
(Rise-Fall, Nominal-Inverted, Divided-Divided) (1,5)  
Output Skew  
(Rise-Rise, Fall-Fall, Different Class Outputs) (1,5)  
0.7  
1.2  
Output Skew  
(Rise-Fall, Nominal-Divided, Divided-Inverted) (1,2)  
Device-to-Device Skew (1,2,6)  
tDEV  
tPD  
0.25  
1.2  
0
0.75  
0.25  
1.2  
2
0.5  
1.2  
0
1.25  
0.5  
1.2  
2.5  
3
0.7  
1.2  
0
1.65  
0.7  
1.2  
3
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ms  
ps  
REF Input to FB Propagation Delay (1,8)  
Output Duty Cycle Variation from 50% (1)  
Output HIGH Time Deviation from 50% (1,9)  
Output LOW Time Deviation from 50% (1,10)  
Output Rise Time (1)  
tODCV  
tPWH  
tPWL  
tORISE  
tOFALL  
tLOCK  
tJR  
0
0
0
1
1
1.5  
1.5  
2.5  
1.8  
1.8  
0.5  
25  
3.5  
2.5  
2.5  
0.5  
40  
0.15  
0.15  
0.15  
0.15  
1.8  
1.8  
0.5  
40  
0.15  
0.15  
Output Fall Time (1)  
1
1
PLL Lock Time (1,7)  
Cycle-to-Cycle Output Jitter (1) RMS  
Peak-to-Peak  
200  
200  
200  
NOTES:  
1. All timing tolerances apply for FNOM > 25MHz.  
2. Skew is the time between the earliest and the latest output transition among all outputs for which the same tU delay has been selected when all are  
loaded with the specified load.  
3. tSKEWPR is the skew between a pair of outputs (xQ0 and xQ1) when all eight outputs are selected for 0tU.  
4. tSKEW0 is the skew between outputs when they are selected for 0tU.  
5. There are 3 classes of outputs: Nominal (multiple of tU delay), Inverted (4Q0 and 4Q1 only with 4F0 = 4F1 = HIGH), and Divided (3Qx and 4Qx only  
in Divide-by-2 or Divide-by-4 mode).  
6. tDEV is the output-to-output skew between any two devices operating under the same conditions (VCC, ambient temperature, air flow, etc.)  
7. tLOCK is the time that is required before synchronization is achieved. This specification is valid only after VCC is stable and within normal operating  
limits. This parameter is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits.  
8. tPD is measured with REF input rise and fall times (from 0.8V to 2V) of 1ns.  
9. Measured at 2V.  
10. Measured at 0.8V.  
11. Refer to Input Timing Requirements table for more detail.  
5
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
AC TEST LOADS AND WAVEFORMS  
VCC  
150  
Output  
150  
20pF  
tOFALL  
tORISE  
2.0V  
0.8V  
tPWH  
tPWL  
LVTTLOUTPUTWAVEFORM  
1ns  
1ns  
3.0V  
2.0V  
Vth = 1.5V  
0.8V  
0V  
LVTTL INPUT TEST WAVEFORM  
6
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
AC TIMING DIAGRAM  
RPWL  
t
REF  
t
tRPWH  
REF  
tPD  
ODCV  
ODCV  
t
t
FB  
JR  
t
Q
tSKEWPR  
tSKEWPR  
SKEW0, 1  
SKEW0, 1  
t
t
OTHER Q  
SKEW2  
t
SKEW2  
t
INVERTED Q  
REF DIVIDED BY 2  
REF DIVIDED BY 4  
SKEW3, 4  
t
SKEW3, 4  
t
SKEW3, 4  
SKEW2, 4  
t
SKEW1, 3, 4  
t
t
NOTES:  
VCCQ/PE: The AC Timing Diagram applies to VCCQ/PE=VCC. For VCCQ/PE=GND, the negative edge of FB aligns with the negative edge of REF, divided  
outputs change on the negative edge of REF, and the positive edges of the divide-by-2 and the divide-by-4 signals align.  
Skew:  
The time between the earliest and the latest output transition among all outputs for which the same tU delay has been selected when all are loaded  
with 20pF and terminated with 75to VCC/2.  
tSKEWPR: The skew between a pair of outputs (xQ0 and xQ1) when all eight outputs are selected for 0tU.  
tSKEW0:  
tDEV:  
The skew between outputs when they are selected for 0tU  
.
The output-to-output skew between any two devices operating under the same conditions (VCC, ambient temperature, air flow, etc.)  
The deviation of the output from a 50% duty cycle. Output pulse width variations are included in tSKEW2 and tSKEW4 specifications.  
tODCV:  
tPWH is measured at 2V.  
tPWL is measured at 0.8V.  
tORISE and tOFALL are measured between 0.8V and 2V.  
tLOCK:  
The time that is required before synchronization is achieved. This specification is valid only after VCC is stable and within normal operating limits.  
This parameter is measured from the application of a new signal or frequency at REF or FB until tPD is within specified limits.  
7
QS5V991  
COMMERCIALANDINDUSTRIALTEMPERATURERANGES  
3.3VPROGRAMMABLESKEWPLLCLOCKDRIVERTURBOCLOCK  
ORDERINGINFORMATION  
XXXXX  
XX  
X
QS  
Package Process  
Device Type  
Commercial (0°C to +70°C)  
Industrial (-40°C to +85°C)  
C
I
Rectangular Plastic Leaded Chip Carrier (J32-1)  
JR  
3.3V Programmable Skew PLL Clock Driver TurboClock  
5V991-2  
5V991-5  
5V991-7  
CORPORATE HEADQUARTERS  
for SALES:  
2975StenderWay  
Santa Clara, CA 95054  
800-345-7015 or 408-727-6116  
fax: 408-492-8674  
www.idt.com*  
*To search for sales office near you, please click the sales button found on our home page or dial the 800# above and press 2.  
The IDT logo is a registered trademark of Integrated Device Technology, Inc.  
Turboclock is a registered trademark of Integrated Device Technology, Inc.  
8

相关型号:

QS5V991-7JRI

PLL Based Clock Driver, QS5 Series, 8 True Output(s), 0 Inverted Output(s), CMOS, PQCC32, PLASTIC, LCC-32
IDT

QS5V9910-2SOC

PLL Based Clock Driver, QS5 Series, 8 True Output(s), 0 Inverted Output(s), CMOS, PDSO24, 0.300 INCH, SOIC-24
IDT

QS5V9910-2SOI

Clock Driver, CMOS, PDSO24
IDT

QS5V9910-5SOC

Clock Driver, CMOS, PDSO24
IDT

QS5V9910-5SOI

PLL Based Clock Driver, QS5 Series, 8 True Output(s), 0 Inverted Output(s), CMOS, PDSO24, 0.300 INCH, SOIC-24
IDT

QS5V9910-7Q

Clock Driver, CMOS, PDSO24
IDT

QS5V9910-7SOI

PLL Based Clock Driver, QS5 Series, 8 True Output(s), 0 Inverted Output(s), CMOS, PDSO24, 0.300 INCH, SOIC-24
IDT

QS5V993-2Q

Clock Driver, CMOS, PDSO28
IDT

QS5V993-2QC

PLL Based Clock Driver, QS5 Series, 8 True Output(s), 0 Inverted Output(s), PDSO28, QSOP-28
IDT

QS5V993-5Q

Clock Driver, CMOS, PDSO28
IDT

QS5V993-5QI

PLL Based Clock Driver, QS5 Series, 8 True Output(s), 0 Inverted Output(s), PDSO28, QSOP-28
IDT

QS5V993-7Q

Clock Driver, CMOS, PDSO28
IDT