AMF2807R5D/CH [INFINEON]
HYBRID - HIGH RELIABILITY RADIATION TOLERANT DC/DC CONVERTER; 混合 - 高可靠性抗辐射DC / DC转换器型号: | AMF2807R5D/CH |
厂家: | Infineon |
描述: | HYBRID - HIGH RELIABILITY RADIATION TOLERANT DC/DC CONVERTER |
文件: | 总7页 (文件大小:123K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PD-94689B
AMF28XXS SERIES
28V Input, Single Output
HYBRID - HIGH RELIABILITY
RADIATION TOLERANT
DC/DC CONVERTER
Description
The AMF28XXS series of DC/DC converter modules
has been specifically designed for operation in
moderate radiation environments supplementing the
higher radiation performance available in the
International Rectifier ART, ARH and G-Series
converters. Environments presented to space vehicles
operating in low earth orbits, launch boosters, orbiting
space stations and similar applications requiring a low
power, high performance converter with moderate
radiation hardness performance will be optimally
served by the AMF28XXS Series.
AMF
Features
n 12 Watts Output Power
n Available in 3.3, 5, 7.5, 12 and 15 Volt Outputs
n 16 - 40 VDC Input Range (28 VDC Nominal)
n Low Input/Output Noise
n Total Ionizing Dose > 25KRads (Si)
The physical configuration of the AMF28XXS series
permits mounting directly to a heat dissipation surface
without the necessity of signal leads penetrating the
heat sink surface. This package configuration permits
greater independence in mounting and more
mechanical security than traditional packages.
International Rectifier’s rugged ceramic seal pins are
used exclusively in the package thereby assuring long
term hermeticity.
n
n
SEE Hardened to LET up to 60 MeV.cm2/mg
-55°C to +125°C Operating Range
n Indefinite Short Circuit Protection
Flexible Mounting
n
n High Power Density
n Fully Isolated - Input to Output and to Case
n Complimentary EMI Filter Available
n Synchronizable From An External Source
n Electrical Performance Similar to
AHF28XXS Series
The AMF28XXS has been designed for high density
using chip and wire hybrid technology that complies
with the class H requirements of MIL-PRF-38534.
Manufactured in a facility fully qualified to MIL-PRF-38534,
these converters are fabricated utilizing DSCC qualified
processes. For available screening options, refer to
device screening table in the data sheet. Applicable
generic lot qualification test data including radiation
performance can be made available on request. Consult
IR Santa Clara for special requirements.
n
Standard Microcircuit Drawings Available
www.irf.com
1
09/15/08
AMF28XXS Series
Specifications
Absolute Maximum Ratings
Recommended Operating Conditions
Input Voltage range
-0.5V to +50VDC
300°C for 10 seconds
Input Voltage range
Output Power
+16V to +40VDC
Soldering temperature
Less than or equal to 12W
Storage case temperature -65°C to +135°C
Operating case temperature -55°C to +125°C
Static Characteristics -55°C ≤ T
≤ +125°C, V =28 V
IN
±5%, C =0, unless otherwise specified.
DC
L
CASE
Group A
Parameter
Input Voltage
Subgroups
Test Conditions
Min
Nom
Max
Unit
16
28
40
V
Vin = 28 Volts, 0% load
Output Voltage
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
1
1
1
1
1
3.25
4.95
6.97
3.30
5.00
7.50
3.35
5.05
7.58
11.88 12.00 12.12
14.85 15.00 15.15
AMF2815S
V
2, 3
2, 3
2, 3
2, 3
2, 3
3.20
4.90
7.35
11.76
14.70
3.40
5.10
7.65
12.24
15.30
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
Output Current 1
Output Power 1
Vin = 16, 28, 40 Volts
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
0
0
0
0
0
3000
2400
1600
1000
800
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
mA
AMF2815S
Vin = 16, 28, and 40 Vdc
1, 2, 3
1, 2, 3
10
12
W
AMF2803R3S
All Others
2
1, 2, 3
Vin = 16, 28, 40 Volts,
BW = 20 Hz to 2 MHz
25
60
mVPP
Output Ripple Voltage
Output Voltage
Regulation
V
= 16, 28, 40 Volts
in
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
1, 2, 3
10
10
10
10
10
25
25
50
50
50
Line
AMF2803R3S
Iout = 0%, 50%, and 100%
max
AMF2805S
AMF2807R5S
AMF2812S
mV
AMF2815S
1, 2, 3
10
50
Load
All
For Notes to Specifications, refer to page 5
2
www.irf.com
AMF28XXS Series
Static Characteristics (Continued) -55°C ≤ T
≤ +125°C, V =28 V
IN DC
±5%, C =0, unless otherwise specified.
CASE
L
Group A
Parameter
Subgroups
Test Conditions
Vin=28V,
Min
Nom
Max
Unit
Input Current
1, 2, 3
Iout=0, Inhibit (pin 1)=open
(AMF2812S and AMF2815S)
(All other Models)
No Load
30
20
50
30
mA
1, 2, 3
1, 2, 3
Inhibit (pin 1) shorted to input
return (pin 7) (All Models)
Inhibit
8.0
20
12
50
Input Ripple Current
Efficiency
Vin = 16, 28, 40 Volts, 100%
load, BW = 20 Hz to 2 MHz
mAPP
1, 3
1, 3
1, 3
1, 3
1, 3
100% load
72
76
77
78
78
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
%
2
2
2
2
2
70
72
73
75
75
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
AMF2815S
Isolation
1
Input to output or any pin to
case (except pin 6) at 500Vdc
100
MΩ
Capacitive Load 3, 4
AMF2803R3S
4
4
4
4
4
No effect on dc performance
500
500
300
200
200
AMF2805S
AMF2807R5S
AMF2812S
µF
W
AMF2815S
1, 2, 3
Short Circuit Power Dissipation
Short Circuit Recovery 4
6.0
4, 5, 6
4, 5, 6
0% load to 100% Load
100% load
20
ms
KHz
Khr
Switching Frequency
MTBF
500
750
550
600
MIL-HDBK-217F
SF @ Tc = 35ºC
36
g
Weight
For Notes to Specifications, refer to page 5
www.irf.com
3
AMF28XXS Series
Dynamic Characteristics -55°C ≤ T
≤ +125°C, V =28 V
IN
±5%, C =0, unless otherwise specified.
DC
L
CASE
Group A
Subgroups
Parameter
Test Conditions
Min
Nom
Max
Unit
Synchronization Input
4, 5, 6
500
2.5
-0.5
700
10
0.8
100
80
KHz
V
V
ns
%
Frequency Range
Pulse Amplitude, Hi 4
Pulse Amplitude, Lo 4
Pulse Rise time 4
Pulse Duty Cycle 4
20
Output Response To Step
Transient Load Changes 5
4, 5, 6
-300
+300
Load step 50% 100%
Load step 0% 50%
All
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
-400
-500
-750
-750
-750
+400
+500
+750
+750
+750
AMF2803R3S
AMF2805S
AMF2807R5S
AMF2812S
mVpk
AMF2815S
Recovery Time, Step Transient
Load Changes 5, 6
AMF2803R3S
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
Load step 50% 100%
Load step 0% 50%
70
70
100
100
100
AMF2805S
AMF2807R5S
µs
AMF2812S
AMF2815S
4, 5, 6
All
2.0
ms
⇔
Input step 16
100% Load
40Vdc
Output Response Transient Step
Line Changes 4, 7
AMF2803R3S
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
-500
-500
-1200
-1500
-1500
+500
+500
+1200 mV
+1500
AMF2805S
AMF2807R5S
pk
AMF2812S
AMF2815S
+1500
Input step 16 ⇔ 40Vdc, 100%
load
Recovery Time Transient Step
Line Changes 4, 7
4, 5, 6
800
µ
s
Turn On Overshoot 8
AMF2803R3S
AMF2805S
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
0% load to 100% load
400
600
600
600
750
mV
pk
AMF2807R5S
AMF2812S
AMF2815S
Turn On Delay 8
4, 5, 6
0% load to 100% load
20
ms
For Notes to Specifications, refer to page 5
4
www.irf.com
AMF28XXS Series
Notes to Specifications
1
2
3
Parameter guaranteed by line and load regulation tests.
Bandwidth guaranteed by design. Tested for 20Hz to 2.0MHz.
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of
the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing
as a short circuit during turn on.
4
Parameter shall be tested as part of design characterization and after design or process changes. Therefore this Parameters shall
be guaranteed to the limit specified.
5
6
7
8
Load step transition time between 2.0 and 10 microseconds.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 % of VOUT at 50 percent load.
Input step transition time between 1.0 and 10 microseconds. Parameter guaranteed by design but not 100% tested.
Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin while power is applied to the input.
Block Diagram
EMI
Filter
8
+Input
+Output
3
Under-Voltage
Detector
Output
Return
4
Primary
Housekeeping
Supply
1
Enable
6
Case
Drive
Pulse Width
Modulator
Error
Amp &
Ref
2
FB
CS
Sync
Input
Input
Return
7
Application Information
Inhibit Function (Enable)
Device Synchronization
When multiple DC/DC converters are utilized in a
single system, significant low frequency noise may
be generated due to a small difference in the
switching frequency of the converters (beat
frequency noise). Because of the low frequency
nature of this noise (typically less than 10 KHz), it is
difficult to filter out and may interfere with proper
operation of sensitive systems (communication,
radar or telemetry). Interenational Rectifier provides
synchronization of multiple AMF type converters to
match switching frequency of the converter to the
frequency of the system clock, thus eliminating this
type of noise.
Connecting the enable input (Pin 1) to input common
(Pin 7) will cause the converter to shut down. It is
recommended that the enable pin be driven by an
open collector device capable of sinking at least
400 µA of current. The open circuit voltage of the
enable input is 10 +1.0 VDC
.
EMI Filter
An optional EMI filter is available (AFH461) that will
reduce the input ripple current to levels below the
limits imposed by MIL-STD-461 CE03.
www.irf.com
5
AMF28XXS Series
Mechanical Outline
1.130
Ø 0.140
0.17
0.03D x 0.25L
8 Pins
1.850 1.600
2.10
1.000
0.800
0.600
0.400
0.19
0.33
1.380
Tolerance unless otherwise specified:
x.xx ±0.010
x.xxx ±0.005
Pin Designation
Pin #
Designation
1
2
3
4
5
6
7
8
Enable
Sync. Input
+ Output
Output Return
NC
Case Ground
Input Return
+ Input
Radiation Specification
Parameter
Condition
Min
Typ
Max
Unit
Total Ionizing Dose
MIL-STD-883, Method 1019.4
Operating bias applied during exposure
25
—
—
KRads
(Si)
MeV cm2
•
Heavy Ion
(Single event effects)
BNL Dual Van de Graf Generator
60
—
—
/mg
International Rectifier currently does not have a DSCC certified Radiation Hardness Assurance Program.
6
www.irf.com
AMF28XXS Series
Device Screening
Requirement
MIL-STD-883 Method
No Suffix
CH
EM
Temperature Range
Element Evaluation
Non-Destructive Bond Pull
Internal Visual
-55°C to +125°C
Class H
N/A
-55°C to +125°C
Class H
N/A
-55°C to +85°C
MIL-PRF-38534
2023
N/A
N/A
2017
Yes
Yes
Temperature Cycle
Constant Acceleration
PIND
1010
Cond C
Cond C
Cond C
3000 Gs
2001, Y1 Axis
2020
3000 Gs
Cond A
3000 Gs
Cond A
N/A
320 hrs @ 125°C
( 2 x 160hrs )
-55°C, +25°C,
+125°C
320 hrs @ 125°C
( 2 x 160hrs )
-55°C, +25°C,
+125°C
48 hrs @ 125°C
Burn-In
1015
Final Electrical
( Group A )
MIL-PRF-38534
& Specification
MIL-PRF-38534
1014
-55°C, +25°C,
+85°C
PDA
2%
2%
N/A
Seal, Fine and Gross
Radiographic
External Visual
Cond A, C
Yes
Cond A, C
Yes
Cond A
N/A
2012
2009
Yes
Yes
Notes:
Best commercial practice.
Device with ‘/CH’ suffix is a DSCC class H compliant without radiation performance. No suffix is a radiation rated
device but not available as a DSCC qualified SMD per MIL-PRF-38534.
International Rectifier currently does not have a DSCC certified Radiation Hardness Assurance Program.
Part Numbering
Standard Microcircuit Drawing Equivalence Table
AMF 28 05 S /EM
Standard Microcircuit
Drawing Number
5962-04252
IR Standard
Part Number
AMF2805S
Model
Screening Level
(Please refer to Screening Table)
No suffix, CH, EM
Input Voltage
5962-04253
AMF2812S
28 = 28V
5962-04254
AMF2815S
Output
S = Single
D = Dual
Output Voltage
03R3 = 3.3V, 05 = 5V
07R5 = 7.5V, 12 = 12V
15 = 15V
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice. 09/2008
www.irf.com
7
相关型号:
©2020 ICPDF网 联系我们和版权申明