HFA200MD40C [INFINEON]
Ultrafast, Soft Recovery Diode; 超快,软恢复二极管型号: | HFA200MD40C |
厂家: | Infineon |
描述: | Ultrafast, Soft Recovery Diode |
文件: | 总5页 (文件大小:295K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PD-2.450 rev. B 01/99
HFA200MD40C
HEXFREDTM
Ultrafast, Soft Recovery Diode
VR = 400V
LUG
TERMINAL
CATHODE
LUG
TERMINAL
ANODE 1
LUG
TERMINAL
ANODE 2
VF(typ.) = 0.9V
IF(AV) = 200A
Reduced RFI and EMI
Reduced Snubbing
Extensive Characterization of
Recovery Parameters
Qrr (typ.) = 330nC
IRRM(typ.)= 8.1A
trr(typ.)= 45ns
Isolated Base
di(rec)M/dt (typ.) = 270A/µs
HEXFREDTM diodes are optimized to reduce losses and EMI/RFI in high frequency
power conditioning systems. An extensive characterization of the recovery
behavior for different values of current, temperature and di/dt simplifies the
calculations of losses in the operating conditions. The softness of the recovery
eliminates the need for a snubber in most applications. These devices are
ideally suited for power converters, motors drives and other applications where
switching losses are significant portion of the total losses.
TO-244AB
(ISOLATED)
Parameter
Max.
Units
VR
Cathode-to-Anode Voltage
400
172
83
1200
1.4
V
IF @ TC = 25°C
IF @ TC = 100°C
IFSM
Continuous Forward Current
Continuous Forward Current
Single Pulse Forward Current
Non-Repetitive Avalanche Energy
Maximum Power Dissipation
A
EAS
mJ
W
PD @ TC = 25°C
PD @ TC = 100°C Maximum Power Dissipation
278
111
TJ
TSTG
Operating Junction and
Storage Temperature Range
C
-55 to +150
Parameter
Min.
Typ.
0.10
Max.
0.45
Units
RthJC
Junction-to-Case, Single Leg Conducting
Junction-to-Case, Both Legs Conducting
Case-to-Sink, Flat , Greased Surface
Weight
°C/W
K/W
0.23
RthCS
Wt
40 (4.6)
40 (4.6)
80
79 (2.8)
g (oz)
Mounting Torque
30 (3.4)
30 (3.4)
lbfin
(Nm)
TerminalTorque
Vertical Pull
lbfin
2 inch Lever Pull
35
Note: Limited by junction temperature
L = 100µH, duty cycle limited by max TJ
125°C
Mounting surface must be smooth, flat, free or burrs or other
protrusions. Apply a thin even film or thermal grease to mounting
surface. Gradually tighten each mounting bolt in 5-10 lbfin steps
until desired or maximum torque limits are reached. Module
1
HFA200MD40C
PD-2.450 rev. B 01/99
J
Parameter
Min. Typ. Max. Units
Test Conditions
VBR
VFM
Cathode Anode Breakdown Voltage
400
1.0 1.2
1.2 1.4
0.9 1.1
2.0 12
3.0 16
370 500
V
IR = 100µA
Max Forward Voltage
IF = 100A
IF = 200A
V
See Fig. 1
IF = 100A, TJ = 125°C
IRM
Max Reverse Leakage Current
µA VR = VR Rated
mA TJ = 125°C, VR = 320V
pF VR = 200V
See Fig. 2
See Fig. 3
CT
LS
Junction Capacitance
Series Inductance
From top of terminal hole to mounting
plane
5.0
nH
J
Parameter
Min. Typ. Max. Units
Test Conditions
trr
Reverse Recovery Time
45
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
trr1
trr2
81 120
260 390
8.1 15
ns TJ = 25°C See Fig.
TJ = 125°C
TJ = 25°C See Fig.
TJ = 125°C
TJ = 25°C See Fig.
TJ = 125°C
TJ = 25°C See Fig.
5
IF = 100A
VR = 200V
IRRM1
IRRM2
Qrr1
Qrr2
Peak Recovery Current
A
17
30
6
Reverse Recovery Charge
330 890
2200 6000
290
270
nC
7
dif/dt = 200A/µs
di(rec)M/dt1 Peak Rate of Fall of Recovery Current
di(rec)M/dt2 During tb
A/µs
TJ = 125°C
8
80.01 (3.150)
40.26 (1.585)
39.75 (1.565)
20.32 (0.800)
17.78 (0.700)
LEAD ASSIGNMENTS
1 - ANODE
2 - CATHODE
3 - ANODE
7.49 (0.295)
6.99 (0.275)
(2 PLCS.)
DIA.
34.925 (1.375)
REF.
63.50 (2.500)
60.96 (2.400)
1/4-20 SLOTTED HEX
1
2
3
OUTLINE TO-244AB (ISOLATED)
Dimensions in Millimeters and (Inches)
23.55 (0.927)
20.42 (0.804)
15.75 (0.620)
14.99 (0.590)
3.35 (0.132)
3.02 (0.119)
92.71 (3.650)
90.17 (3.550)
2
HFA200MD40C
PD-2.450 rev. B 01/99
1000
100
10
100000
10000
1000
100
T = 150°C
J
T = 125°C
J
T = 150°C
10
J
T = 125°C
T = 25°C
J
J
1
T = 25°C
J
0.1
0
100
200
300
400
Reverse Voltage - V (V)
R
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage, (per Leg)
A
10000
T = 25°C
J
1000
1
0.4
0.8
1.2
1.6
2.0
Forward Voltage Drop - V
(V)
FM
100
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current,
(per Leg)
1
10
100
1000
Reverse Voltage - V (V)
R
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage, (per Leg)
1
D = 0.50
D = 0.33
D = 0.25
D = 0.17
0.1
P
DM
D = 0.08
t
1
t
2
0.01
Notes:
1. Duty factor D = t / t
Single Pulse
(Thermal Resistance)
1
2
2. Peak T = P
J
x Z
+ T
DM
thJC
C
0.001
0.00001
0.0001
0.001
0.01
0.1
1
10
100
t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics, (per Leg)
3
HFA200MD40C
PD-2.450 rev. B 01/99
100
10
1
500
VR = 200V
TJ = 125°C
TJ = 25°C
VR = 200V
TJ = 125°C
TJ = 25°C
400
300
200
100
0
I
F
= 200A
I
= 200A
F
I
= 100A
F
I
= 100A
I
= 70A
F
F
I
= 70A
F
100
1000
100
1000
di /dt - (A/µs)
f
di /dt - (A/µs)
f
Fig. 6 - Typical Recovery Current vs. dif/dt,
Fig. 5 - Typical Reverse Recovery vs. dif/dt,
(per Leg)
(per Leg)
6000
10000
VR = 200V
TJ = 125°C
TJ = 25°C
VR = 200V
TJ = 125°C
TJ = 25°C
I
F
= 200A
4000
2000
0
I
= 100A
F
I
= 70A
F
I
= 70A
F
1000
I
= 100A
F
I
= 200A
F
100
100
100
1000
1000
di /dt - (A/µs)
di /dt - (A/µs)
f
f
Fig. 7 - Typical Stored Charge vs. dif/dt,
Fig. 8 - Typical di(rec)M/dt vs. dif/dt,
(per Leg)
(per Leg)
4
HFA200MD40C
PD-2.450 rev. B 01/99
3
t
rr
I
F
t
t
a
b
0
REVERSE RECOVERY CIRCUIT
4
Q
rr
V
= 200V
2
R
I
0.5 I
RRM
RRM
5
di(rec)M/dt
Ω
0.01
0.75 I
RRM
L = 70µH
1
di /dt
f
D.U.T.
1. dif/dt - Rate of change of current
through zero crossing
4. Qrr - Area under curve defined by trr
D
and IRRM
dif/dt
ADJUST
trr X IRRM
IRFP250
G
2. IRRM - Peak reverse recovery current
Q =
rr
2
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
S
5. di(rec)M/dt - Peak rate of change of
current during tb portion of t
rr
Fig. 10 - Reverse Recovery Waveform and
Fig. 9 - Reverse Recovery Parameter Test
Definitions
Circuit
I
L = 100µH
L(PK)
HIGH-SPEED
SWITCH
DUT
FREE-WHEEL
DIODE
Rg = 25 ohm
+
CURRENT
MONITOR
DECAY
TIME
Vd = 50V
V
(AVAL)
V
R(RATED)
Fig. 11 - Avalanche Test Circuit and Waveforms
WORLDHEADQUARTERS: 233 Kansas St., El Segundo, California 90245 U.S.A. Tel: (310) 322 3331. Fax: (310) 322 3332.
EUROPEANHEADQUARTERS: Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408.
IRCANADA: 15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801.
IR GERMANY: Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933.
IRITALY: Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220.
IR FAR EAST: K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086.
IR SOUTHEAST ASIA: 1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630.
IR TAIWAN: 16 Fl. Suite D.207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan. Tel: 886 2 2377 9936.
http://www.irf.com
Fax-On-Demand: +44 1883 733420
Data and specifications subject to change without notice.
5
相关型号:
©2020 ICPDF网 联系我们和版权申明