HYS72D64000GU-8-A [INFINEON]
2.5 V 184-pin Unbuffered DDR-I SDRAM Modules; 2.5 V 184针无缓冲DDR- SDRAM我模块型号: | HYS72D64000GU-8-A |
厂家: | Infineon |
描述: | 2.5 V 184-pin Unbuffered DDR-I SDRAM Modules |
文件: | 总18页 (文件大小:288K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
2.5 V 184-pin Unbuffered DDR-I SDRAM Modules
512 MByte & 1024 MByte Modules
PC1600, PC2100 & PC2700
Preliminary datasheet rev. 0.81
•
184-pin Unbuffered 8-Byte Dual-In-Line
DDR-I SDRAM non-parity and ECC-Modules
for PC and Server main memory applications
•
•
•
•
Auto Refresh (CBR) and Self Refresh
All inputs and outputs SSTL_2 compatible
Serial Presence Detect with E2PROM
•
•
One bank 64M x 64, 64M x 72 and two bank
128M x 64, 128M × 72 organization
Jedec standard MO-206 form factor:
133.35 mm × 31.75 mm × 4.00 mm max.
JEDEC standard Double Data Rate
Synchronous DRAMs (DDR-I SDRAM)
Single + 2.5 V (± 0.2 V) power supply
•
•
Jedec standard reference layout
Gold plated contacts
•
•
Built with 512 Mbit DDR-I SDRAMs organized
as 64Mb x 8 in 66-Lead TSOPII package
Programmable CAS Latency, Burst Length,
and Wrap Sequence (Sequential &
Interleave)
•
Performance:
-6
-7
-8
Unit
Component Speed Grade
Module Speed Grade
DDR333B DDR266A DDR200
PC2700
166
PC2100
143
PC1600
125
fCK
fCK
Clock Frequency (max.) @ CL = 2.5
Clock Frequency (max.) @ CL = 2
MHz
MHz
133
133
100
The HYS64/72D64000GU and HYS64/72D128020GU are industry standard 184-pin 8-byte Dual
in-line Memory Modules (DIMMs) organized as 64M × 64 and 128M × 64 for non-parity and 64M x
72 and 128M x 72 for ECC main memory applications. The memory array is designed with 512Mbit
Double Data Rate Synchronous DRAMs. A variety of decoupling capacitors are mounted on the PC
board. The DIMMs feature serial presence detect based on a serial E2PROM device using the 2-pin
I2C protocol. The first 128 bytes are programmed with configuration data and the second 128 bytes
are available to the customer.
INFINEON Technologies
1
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Ordering Information
Type
Compliance Code
Description
SDRAM
Technology
PC2700 (CL=2.5):
HYS64D128320GU-6-A
HYS72D128320GU-6-A
PC2100 (CL=2):
PC2700-25330-B1
PC2700-25330-B1
two banks 1024 MB DIMM
512 MBit
512 MBit
two banks 1024 MB ECC-DIMM
HYS64D64000GU-7-A
HYS72D64000GU-7-A
HYS64D128020GU-7-A
HYS72D128020GU-7-A
PC1600 (CL=2):
PC2100-20330-A1
PC2100-20330-A1
PC2100-20330-B1
PC2100-20330-B1
one bank 512 MB DIMM
512 MBit
512 Mbit
512 MBit
512 MBit
one bank 512 MB ECC-DIMM
two banks 1024 MB DIMM
two banks 1024 MB ECC-DIMM
HYS64D64000GU-8-A
HYS72D64000GU-8-A
HYS64D128020GU-8-A
HYS72D128020GU-8-A
PC1600-20220-A1
PC1600-20220-A1
PC1600-20220-B1
PC1600-20220-B1
one bank 512 MB DIMM
512 MBit
512 Mbit
512 MBit
512 MBit
one bank 512 MB ECC-DIMM
two banks 1024 MB DIMM
two banks 1024 MB ECC-DIMM
Note: All part numbers end with a place code, designating the silicon-die revision. Reference information
available on request. Example: HYS 72D64000GU-8-A, indicating Rev.A dies are used for the SDRAM
components.
The Compliance Code is printed on the module labels and describes the speed sort fe. “PC2100”, the
latencies (f.e. “20330” means CAS latency = 2, trcd latency = 3 and trp latency =3 ) and the Raw Card
used for this module.
INFINEON Technologies
2
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Pin Definitions and Functions
A0 - A12
Address Inputs
S0, S1
Chip Selects
BA0, BA1
DQ0 - DQ63
CB0 - CB7
RAS
Bank Selects
VDD
Power (+ 2.5 V)
Data Input/Output
VSS
Ground
Check Bits (x72 organization only)
Row Address Strobe
Column Address Strobe
Read/Write Input
VDDQ
VDDID
VREF
I/O Driver power supply
VDD Indentification flag
I/O reference supply
Serial EEPROM power supply
Serial bus clock
CAS
WE
VDDSPD
SCL
CKE0 - CKE1
DQS0 - DQS8
CLK0 - CLK2,
CLK0 - CLK2
Clock Enable
SDRAM low data strobes
SDRAM clock (positive lines)
SDRAM clock (negative lines)
SDA
SA0 - SA2
NC
Serial bus data line
slave address select
no connect
DM0 - DM8
DQS9 - DQS17
SDRAM low data mask/
high data strobes
note: S1 and CKE1 are used on two bank modules only
Address Format
Density Organization
Memory SDRAMs
Banks
# of
# of row/bank/
Refresh Period Interval
SDRAMs columns bits
512 MB 64M x 64
512 MB 64M x 72
1024 MB 128M × 64
1024 MB 128M × 72
1
1
2
2
64M x 8
64M x 8
64M x 8
64M x 8
8
13/2/11
13/2/11
13/2/11
13/2/11
8k
8k
8k
8k
64 ms 7.8 µs
64 ms 7.8 µs
64 ms 7.8 µs
64 ms 7.8 µs
9
16
18
INFINEON Technologies
3
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Pin Configuration
Frontside
Frontside
Backside
Backside
PIN#
1
Symbol
VREF
DQ0
PIN#
48
Symbol
A0
PIN#
93
Symbol
VSS
PIN#
140
141
142
143
144
Symbol
NC / DM8/DQS17
A10
2
49
NC / CB2
VSS
94
DQ4
3
VSS
50
95
DQ5
NC / CB6
VDDQ
NC / CB7
KEY
4
DQ1
51
NC / CB3
BA1
96
VDDQ
DM0/DQS9
DQ6
5
DQS0
DQ2
52
97
6
KEY
98
7
VDD
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
DQ32
VDDQ
DQ33
DQS4
DQ34
VSS
99
DQ7
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
VSS
8
DQ3
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
VSS
DQ36
9
NC
NC
DQ37
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
NC
NC
VDD
VSS
NC
DM4/DQS13
DQ38
DQ8
VDDQ
DQ12
DQ13
DM1/DQS10
VDD
DQ9
BA0
DQ39
DQS1
VDDQ
CLK1
CLK1
VSS
DQ35
DQ40
VDDQ
WE
VSS
DQ44
RAS
DQ14
DQ15
CKE1
VDDQ
NC (BA2)
DQ20
NC / A12
VSS
DQ45
DQ41
CAS
VDDQ
S0
DQ10
DQ11
CKE0
VDDQ
DQ16
DQ17
DQS2
VSS
VSS
S1
DQS5
DQ42
DQ43
VDD
DM5/DQS14
VSS
DQ46
DQ47
NC
DQ21
A11
NC
DQ48
DQ49
VSS
VDDQ
DQ52
A9
DM2/DQS11
VDD
DQ18
A7
DQ53
CLK2
CLK2
VDDQ
DQS6
DQ50
DQ51
VSS
DQ22
A8
NC (A13)
VDD
VDDQ
DQ19
A5
DQ23
VSS
DM6/DQS15
DQ54
DQ24
VSS
A6
DQ55
DQ28
DQ29
VDDQ
DM3/DQS12
A3
VDDQ
NC
DQ25
DQS3
A4
VDDID
DQ56
DQ57
VDD
DQ60
DQ61
VDD
VSS
DQ26
DQ27
A2
DQ30
VSS
DM7/DQS16
DQ62
DQS7
DQ58
DQ59
VSS
DQ31
NC / CB4
NC / CB5
VDDQ
CK0
DQ63
VSS
VDDQ
SA0
A1
NC / CB0
NC / CB1
VDD
NC
SA1
SDA
SA2
SCL
CK0
VDDSPD
NC / DQS8
VSS
Note: Pins 44, 45, 47, 49, 51, 134, 135, 140 and 144 are NC (“no-connects”) on x64 organised non-ECC
modules.
INFINEON Technologies
4
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
S0
DQS0
DQS4
DM4/DQS13
DM0/DQS9
CS
D4
DM
I/O 7
DQS
DQS
DM
I/O 7
CS
D0
DQ32
DQ33
DQ34
DQ35
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ36
DQ37
DQ38
DQ39
DQS5
DQS1
DM5/DQS14
DM1/DQS10
CS DQS
D5
DM
DQS
CS
D1
DM
DQ40
DQ41
DQ42
DQ43
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ8
DQ9
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
DQ10
DQ11
DQ12
DQ13
DQ14
DQ15
DQ44
DQ45
DQ46
DQ47
I/O 3
I/O 2
DQS6
DM6/DQS15
DQS2
DM2/DQS11
DM
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS
CS
D6
CS DQS
D2
DM
I/O 7
DQ48
DQ49
DQ50
DQ51
DQ52
DQ53
DQ54
DQ55
DQ16
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS3
DM3/DQS12
DQS7
DM7/DQS16
DQS
DM
I/O 7
CS
D7
DM
CS DQS
D3
DQ56
DQ57
DQ58
DQ59
DQ60
DQ61
DQ62
DQ63
DQ24
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ25
DQ26
DQ27
DQ28
DQ29
DQ30
DQ31
* Clock Wiring
Clock
Input
SDRAMs
Serial PD
2 SDRAMs
3 SDRAMs
3 SDRAMs
*CK0/CK0
*CK1/CK1
*CK2/CK2
SDA
SCL
A0
SA0
A1
A2
* Wire per Clock Loading
Table/Wiring Diagrams
SA1
SA2
BA0 - BA1
BA0, BA1: SDRAMs D0
- D7
Notes:
A0 - A11,A12: SDRAMs D0 - D7
A0 -A11, A12
1. DQ-to-I/O wiring is shown as recom-
mended but may be changed.
2. DQ/DQS/DM/CKE/S relationships must
be maintained as shown.
3. DQ, DQS, DM/DQS resistors: 22 Ohms.
4. VDDID strap connections
RAS
RAS: SDRAMs D0 - D7
V
V
DD, DDQ
D0 - D7
D0 - D7
D0 - D7
CAS
CKE0
WE
CAS: SDRAMs D0 - D7
CKE: SDRAMs D0 - D7
VREF
V
V
SS
: SDRAMs D0 - D7
WE
DDID
(for memory device VDD, VDDQ):
STRAP OUT (OPEN): VDD = VDDQ
Block Diagram: One Bank 64M x 64 DDR-I SDRAM DIMM Module
HYS64D64000GU using x8 organized SDRAMs
INFINEON Technologies
5
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
S1
S0
DQS4
DM4/DQS13
DQS0
DM0/DQS9
CS
D4
CS
DM
I/O 7
DQS
DM
I/O 0
DQS
DQS
CS
D0
DM
CS DQS
D8
DM
I/O 7
DQ32
DQ33
DQ34
DQ35
DQ36
DQ37
DQ38
DQ39
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ0
DQ1
DQ2
DQ3
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
D12
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ4
DQ5
DQ6
DQ7
DQS5
DQS1
DM5/DQS14
DM1/DQS10
CS
DM
DM
CS
D5
DQS
DQS
DQS
CS
D1
CS DQS
D9
DM
DM
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ40
DQ41
DQ42
DQ43
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
DQ8
DQ9
DQ10
DQ11
DQ12
DQ13
DQ14
DQ15
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
D13
DQ44
DQ45
DQ46
DQ47
I/O 4
I/O 5
I/O 3
I/O 2
DQS6
DM6/DQS15
DQS2
DM2/DQS11
DM
DM
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
CS
D6
DQS
CS DQS
D14
CS DQS
D2
DM
I/O 0
CS DQS
D10
DM
I/O 7
DQ48
DQ49
DQ50
DQ51
DQ52
DQ53
DQ54
DQ55
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ16
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS7
DM7/DQS16
DQS3
DM3/DQS12
DM
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DM
DQS
DQS
CS
CS
D7
DM
CS DQS
D3
DM
CS
DQS
DQ56
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ24
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ57
DQ58
DQ59
DQ60
DQ61
DQ62
DQ63
D15
DQ25
DQ26
DQ27
DQ28
DQ29
DQ30
DQ31
D11
* Clock Wiring
Clock
Input
SDRAMs
BA0, BA1: SDRAMs D0, D15
A0 - A12: SDRAMs D0 - D15
BA0, BA1
A0 - A12
Serial PD
A1
4 SDRAMs
6 SDRAMs
6 SDRAMs
*CK0/CK0
*CK1/CK1
*CK2/CK2
SDA
V
V
DD, DDQ
D0 - D15
D0 - D15
SCL
A0
SA0
A2
VREF
* Wire per Clock Loading
Table/Wiring Diagrams
SA1
SA2
V
SS
D0 - D15
V
DDID
Notes:
1. DQ-to-I/O wiring is shown as recom-
mended but may be changed.
2. DQ/DQS/DM/CKE/S relationships must
be maintained as shown.
CKE1
RAS
CKE: SDRAMs D8 - D15
RAS: SDRAMs D0 - D15
3. DQ, DQS, DM/DQS resistors: 22 Ohms.
4. VDDID strap connections
(for memory device VDD, VDDQ):
STRAP OUT (OPEN): VDD = VDDQ
CAS
CKE0
WE
CAS: SDRAMs D0 - D15
CKE: SDRAMs D0 - D7
WE: SDRAMs D0 - D15
Block Diagram: Two Bank 128M x 64 DDR-I SDRAM DIMM Modules
HYS64D128020GU using x8 Organized SDRAMs
INFINEON Technologies
6
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
S0
DQS0
DQS4
DM4/DQS13
DM0/DQS9
DM
I/O 7
DQS
DQS
CS
D0
CS
D4
DM
I/O 7
DQ32
DQ33
DQ34
DQ35
DQ36
DQ37
DQ38
DQ39
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS5
DQS1
DM5/DQS14
DM1/DQS10
CS
D5
DM
DQS
DQS
CS
D1
DM
DQ40
DQ41
DQ42
DQ43
DQ44
DQ45
DQ46
DQ47
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ8
DQ9
DQ10
DQ11
DQ12
DQ13
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
DQ14
DQ15
I/O 3
I/O 2
DQS6
DM6/DQS15
DQS2
DM2/DQS11
DM
I/O 7
CS DQS
D6
DM
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
CS DQS
D2
DQ48
DQ49
DQ50
DQ51
DQ52
DQ53
DQ54
DQ55
DQ16
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
DQS3
DM3/DQS12
DQS7
DM7/DQS16
DM
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS
CS
D3
CS
D7
DQS
DM
DQ56
DQ57
DQ58
DQ59
DQ24
I/O 7
DQ25
DQ26
DQ27
DQ28
DQ29
DQ30
DQ31
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ60
DQ61
DQ62
DQ63
DQS8
DM8/DQS17
Serial PD
A1
DM
DQS
CS
D8
CB0
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
CB1
CB2
CB3
CB4
CB5
CB6
CB7
SDA
SCL
A0
SA0
A2
SA2
SA1
BA0, BA1: SDRAMs D0
- D8
BA0, BA1
* Clock Wiring
A0 - A11,A12
A0 - A11, A12: SDRAMs D0 - D8
Clock
Input
SDRAMs
RAS
RAS: SDRAMs D0 - D8
V
V
DD, DDQ
D0 - D8
D0 - D8
D0 - D8
3 SDRAMs
3 SDRAMs
3 SDRAMs
*CK0/CK0
*CK1/CK1
*CK2/CK2
CAS
CAS: SDRAMs D0 - D8
CKE: SDRAMs D0 - D8
VREF
CKE0
V
SS
WE
WE: SDRAMs D0 - D8
* Wire per Clock Loading
Table/Wiring Diagrams
V
DDID
Notes:
1. DQ-to-I/O wiring is shown as recom-
mended but may be changed.
2. DQ/DQS/DM/CKE/S relationships must
be maintained as shown.
3. DQ, DQS, DM/DQS resistors: 22 Ohms.
4. VDDID strap connections
(for memory device VDD, VDDQ):
STRAP OUT (OPEN): VDD = VDDQ
Block Diagram: One Bank 64M x 72 DDR-I SDRAM DIMM Module
HYS72D64000GU using x8 organized SDRAMs
INFINEON Technologies
7
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
S1
S0
DQS4
DM4/DQS13
DQS0
DM0/DQS9
DM
I/O 0
DM
I/O 7
CS DQS
D4
CS DQS
D13
DQS
CS
D0
CS
D9
DM
DQS
DM
I/O 7
DQ32
DQ33
DQ34
DQ35
DQ36
DQ37
DQ38
DQ39
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ0
DQ1
DQ2
DQ3
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQ4
DQ5
DQ6
DQ7
DQS5
DM5/DQS14
DQS1
DM1/DQS10
CS
DM
CS
DM
DQS
DQS
CS
DQS
DQS
DM
DM
CS
D1
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ40
DQ41
DQ42
DQ43
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
DQ8
DQ9
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
D5
D14
D10
DQ10
DQ11
DQ12
DQ13
DQ14
DQ15
DQ44
DQ45
DQ46
DQ47
I/O 4
I/O 5
I/O 3
I/O 2
DQS6
DM6/DQS15
DQS2
DM2/DQS11
CS
D6
CS
DM
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS
DM
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQS
DQS
DQS
DQS
DM
I/O 0
DQS
DQS
DQS
DM
I/O 7
CS
D2
CS
DQ48
DQ49
DQ50
DQ51
DQ16
D15
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ17
DQ18
DQ19
DQ20
DQ21
DQ22
DQ23
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
D11
DQ52
DQ53
DQ54
DQ55
DQS7
DQS3
DM3/DQS12
DM7/DQS16
CS
D7
DM
I/O 0
CS
DQS
DM
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
DQS
DM
DM
CS
D3
CS
DQ56
I/O 0
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ24
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 1
I/O 6
I/O 7
I/O 2
I/O 3
I/O 4
I/O 5
DQ57
DQ58
DQ59
DQ60
DQ61
DQ62
DQ63
D16
DQ25
DQ26
DQ27
D12
DQ28
DQ29
DQ30
DQ31
DQS8
DM8/DQS17
CS
DM
CS
D8
DM
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
I/O 7
I/O 6
I/O 1
I/O 0
I/O 5
I/O 4
I/O 3
I/O 2
CB0
CB1
CB2
CB3
CB4
CB5
CB6
CB7
D17
* Clock Wiring
Clock
Input
SDRAMs
BA0, BA1
A0 - A12
BA0, BA1: SDRAMs D0 - D17
A0 - A12: SDRAMs D0 - D17
Serial PD
A1
6 SDRAMs
6 SDRAMs
6 SDRAMs
*CK0/CK0
*CK1/CK1
*CK2/CK2
SDA
SCL
A0
SA0
A2
V
V
DD,
DDQ
D0 - D17
D0 - D17
* Wire per Clock Loading
Table/Wiring Diagrams
VREF
SA1
SA2
V
SS
D0 - D17
Notes:
V
DDID
1. DQ-to-I/O wiring is shown as recom-
mended but may be changed.
2. DQ/DQS/DM/CKE/S relationships must
be maintained as shown.
CKE1
RAS
CKE: SDRAMs D9 - D17
RAS: SDRAMs D0 - D17
3. DQ, DQS, DM/DQS resistors: 22 Ohms.
4. VDDID strap connections
(for memory device VDD, VDDQ):
STRAP OUT (OPEN): VDD = VDDQ
CAS
CKE0
WE
CAS: SDRAMs D0 - D17
CKE: SDRAMs D0 - D8
WE: SDRAMs D0 - D17
Block Diagram: Two Bank 128M x 72 DDR-I SDRAM DIMM Modules
HYS72D128020GU using x8 Organized SDRAMs
INFINEON Technologies
8
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Clock Net Wiring
4 DRAM Loads
6 DRAM Loads
DRAM 1
DR AM 1
DRAM2
DRAM3
DRAM2
R = 120
CK
R =
120
Cap.
DIMM
DIMM
Connector
Connector
DR AM4
DR AM5
Cap.
CK
DRAM5
DR AM6
DRAM6
DRAM 1
2 DRAM Loads
3 DRAM Loads
DRAM 1
Cap.
Cap.
Cap.
R =120
R =120
DIMM
Connector
DRAM3
DIMM
Connector
Cap.
Cap.
DR AM5
DR AM5
Cap.
Cap.
Absolute Maximum Ratings
Parameter
Symbol
Limit Values
Unit
min.
max.
3.6
3.6
+150
1
Input / Output voltage relative to VSS
Power supply voltage on VDD/VDDQ to VSS
Storage temperature range
VIN, VOUT – 0.5
VDD, VDDQ – 0.5
V
V
TSTG
PD
-55
–
oC
W
mA
Power dissipation (per SDRAM component)
Data out current (short circuit)
IOS
–
50
Permanent device damage may occur if “Absolute Maximum Ratings” are exceeded.
Functional operation should be restricted to recommended operation conditions.
Exposure to higher than recommended voltage for extended periods of time affect device reliability
INFINEON Technologies
9
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Supply Voltage Levels
Parameter
Symbol
Limit Values
nom.
Unit
Notes
min.
max.
Device Supply Voltage
Output Supply Voltage
Input Reference Voltage
Termination Voltage
VDD
2.3
2.5
2.7
V
V
V
V
V
–
1)
VDDQ
VREF
VTT
2.3
2.5
2.7
2)
3)
0.49 x VDDQ
VREF – 0.04
2.3
0.5 x VDDQ
VREF
0.51 x VDDQ
VREF + 0.04
3.6
EEPROM supply voltage
VDDSPD
2.5
1)
Under all conditions, VDDQ must be less than or equal to VDD
.
2)
Peak to peak AC noise on VREF may not exceed ± 2% VREF (DC). VREF is also expected to track noise variations
in VDDQ
VTT of the transmitting device must track VREF of the receiving device.
.
3)
DC Operating Conditions (SSTL_2 Inputs)
(VDDQ = 2.5 V, TA = 70 °C, Voltage Referenced to VSS
)
Parameter
Symbol
Limit Values
max.
Unit
Notes
min.
1)
DC Input Logic High
DC Input Logic Low
Input Leakage Current
Output Leakage Current
VIH (DC)
VIL (DC)
IIL
VREF + 0.15
– 0.30
– 5
VDDQ + 0.3
V
VREF – 0.15
V
–
2)
5
5
µA
µA
2)
IOL
– 5
1)
The relationship between the VDDQ of the driving device and the VREF of the receiving device is what determines
noise margins. However, in the case of VIH (max) (input overdrive), it is the VDDQ of the receiving device that is
referenced. In the case where a device is implemented such that it supports SSTL_2 inputs but has no SSTL_2
outputs (such as a translator), and therefore no VDDQ supply voltage connection, inputs must tolerate input
overdrive to 3.0 V (High corner VDDQ + 300 mV).
2)
For any pin under test input of 0 V ≤ VIN ≤ VDDQ + 0.3 V. Values are shown per DDR-SDRAM component.
INFINEON Technologies
10
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Operating, Standby and Refresh Currents (PC1600)
512MB
x64
1bank
-8
512MB
x72
1bank
-8
1GB
x64
2bank
-8
1GB
x72
2bank
-8
Notes
Symbol
Parameter/Condition
Unit
mA
4
1
MAX
MAX
MAX
MAX
: one bank; active / precharge; tRC = tRC MIN; tCK =
Operating Current
IDD0
tCK MIN; DQ, DM, and DQS inputs changing once per clock cycle;
1280
1440
1680
1890
address and control inputs changing once every two clock cycles
: one bank; active/read/precharge; Burst = 4;
Operating Current
IDD1
1360
96
1530
108
1760
192
1980
216
mA
mA
1, 3
2
Refer to the following page for detailed test conditions.
: all banks idle; power-down
Precharge Power-Down Standby Current
IDD2P
mode; CKE <= VIL MAX; tCK = tCK MIN
: /CS >= VIH MIN, all banks idle;
Precharge Floating Standby Current
CKE >= VIH MIN; tCK = tCK MIN ,address and other control inputs
changing once per clock cycle, VIN = VREF for DQ, DQS and DM.
320
360
640
720
IDD2F
IDD2Q
mA
2
: /CS >= VIH MIN, all banks idle;
Precharge Quiet Standby Current
CKE >= VIH MIN; tCK = tCK MIN ,address and other control inputs
stable at >= VIH MIN or <= VIL MAX; VIN = VREF for DQ, DQS and DM.
200
128
225
144
400
256
450
288
mA
mA
2
2
: one bank active; power-down
Active Power-Down Standby Current
IDD3P mode; CKE <= VIL MAX; tCK = tCK MIN;VIN = VREF for DQ, DQS and
DM.
: one bank active; active / precharge;CS >= VIH
Active Standby Current
MIN; CKE >= VIH MIN; tRC = tRAS MAX; tCK = tCK MIN; DQ, DM, and
DQS inputs changing twice per clock cycle; address and control inputs
changing once per clock cycle
IDD3N
IDD4R
IDD4W
400
450
800
900
mA
mA
mA
2
: one bank active; Burst = 2; reads; continuous burst;
Operating Current
address and control inputs changing once per clock cycle; 50% of data
outputs changing on every clock edge; CL = 2 for DDR200, and
DDR266A, CL=3 for DDR333; tCK = tCK MIN; IOUT = 0mA
1320
1280
1485
1440
1720
1680
1935
1890
1, 3
: one bank active; Burst = 2; writes; continuous burst;
Operating Current
address and control inputs changing once per clock cycle; 50% of data
outputs changing on every clock edge; CL = 2 for DDR200, and
DDR266A, CL=3 for DDR333; tCK = tCK MIN
1
1
: tRC = tRFC MIN, distributed refresh
Auto-Refresh Current
2320
40
2610
45
2720
80
3060
90
IDD5
IDD6
mA
mA
: CKE <= 0.2V; external clock on; tCK = tCK MIN
Self-Refresh Current
: four bank; four bank interleaving with BL=4;
Refer to the following page for detailed test conditions.
Operating Current
IDD7
2800
3150
3200
3600
mA
1, 3
1. The module IDD values are calculated from the component IDD datasheet values as:
n * IDDx[component]
for single bank modules (n: number of components per module bank)
n * IDDx[component] + n * IDD3N[component]
for two bank modules (n: number of components per module bank)
2. The module IDD values are calculated from the component IDD datasheet values as:
n * IDDx[component]
2 * n * IDDx[component]
for single bank modules (n: number of components per module bank)
for two bank modules (n: number of components per module bank)
3. DQ I/O (IDDQ) currents are not included into calculations: module IDD values will be measured differently depending on load conditions
4. Test condition for maximum values: VDD = 2.7V ,Ta = 10°C
INFINEON Technologies
11
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Operating, Standby and Refresh Currents (PC2100 and PC2700)
512MB 512MB 1GB
x64 x72 x64
1bank 1bank 2bank 2bank 2bank 2bank
-7 -7 -6 -6 -7 -7
MAX MAX MAX MAX MAX MAX
1GB
x72
1GB
x64
1GB
x72
Notes
Symbol
Parameter/Condition
Unit
mA
4
1
: one bank; active / precharge; tRC = tRC MIN; tCK =
Operating Current
IDD0
tCK MIN; DQ, DM, and DQS inputs changing once per clock cycle;
1360
1530
2200
2475
1920
2160
address and control inputs changing once every two clock cycles
: one bank; active/read/precharge; Burst = 4;
Operating Current
IDD1
1440
112
1620
126
2320
288
2610
324
2000
224
2250
252
mA
mA
1, 3
2
Refer to the following page for detailed test conditions.
: all banks idle; power-down
Precharge Power-Down Standby Current
IDD2P
mode; CKE <= VIL MAX; tCK = tCK MIN
: /CS >= VIH MIN, all banks idle;
Precharge Floating Standby Current
CKE >= VIH MIN; tCK = tCK MIN ,address and other control inputs
changing once per clock cycle, VIN = VREF for DQ, DQS and DM.
400
450
960
1080
800
900
IDD2F
IDD2Q
mA
2
: /CS >= VIH MIN, all banks idle;
Precharge Quiet Standby Current
CKE >= VIH MIN; tCK = tCK MIN ,address and other control inputs
stable at >= VIH MIN or <= VIL MAX; VIN = VREF for DQ, DQS and DM.
224
144
252
162
640
368
720
414
448
288
504
324
mA
mA
2
2
: one bank active; power-down
Active Power-Down Standby Current
IDD3P mode; CKE <= VIL MAX; tCK = tCK MIN;VIN = VREF for DQ, DQS and
DM.
: one bank active; active / precharge;CS >= VIH
Active Standby Current
MIN; CKE >= VIH MIN; tRC = tRAS MAX; tCK = tCK MIN; DQ, DM, and
DQS inputs changing twice per clock cycle; address and control inputs
changing once per clock cycle
IDD3N
IDD4R
IDD4W
560
630
1200
2560
2480
1350
2880
2790
1120
2160
2120
1260
2430
2385
mA
mA
mA
2
: one bank active; Burst = 2; reads; continuous burst;
Operating Current
address and control inputs changing once per clock cycle; 50% of data
outputs changing on every clock edge; CL = 2 for DDR200, and
DDR266A, CL=3 for DDR333; tCK = tCK MIN; IOUT = 0mA
1600
1560
1800
1755
1, 3
: one bank active; Burst = 2; writes; continuous burst;
Operating Current
address and control inputs changing once per clock cycle; 50% of data
outputs changing on every clock edge; CL = 2 for DDR200, and
DDR266A, CL=3 for DDR333; tCK = tCK MIN
1
1
: tRC = tRFC MIN, distributed refresh
Auto-Refresh Current
2480
40
2790
45
3280
80
3690
90
3040
80
3420
90
IDD5
IDD6
mA
mA
: CKE <= 0.2V; external clock on; tCK = tCK MIN
Self-Refresh Current
: four bank; four bank interleaving with BL=4;
Refer to the following page for detailed test conditions.
Operating Current
IDD7
3040
3420
3840
4320
3600
4050
mA
1, 3
1. The module IDD values are calculated from the component IDD datasheet values as:
n * IDDx[component]
for single bank modules (n: number of components per module bank)
n * IDDx[component] + n * IDD3N[component]
for two bank modules (n: number of components per module bank)
2. The module IDD values are calculated from the component IDD datasheet values as:
n * IDDx[component]
2 * n * IDDx[component]
for single bank modules (n: number of components per module bank)
for two bank modules (n: number of components per module bank)
3. DQ I/O (IDDQ) currents are not included into calculations: module IDD values will be measured differently depending on load conditions
4. Test condition for maximum values: VDD = 2.7V ,Ta = 10°C
INFINEON Technologies
12
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Electrical Characteristics & AC Timing for DDR-I components
(for reference only)
(0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V)
DDR333
-6
DDR266A
-7
DDR200
-8
Symbol
tAC
Parameter
Unit Notes
Min
− 0.7
− 0.7
0.45
0.45
Max
+ 0.7
+ 0.7
0.55
0.55
Min
Max
Min
Max
+ 0.8
+ 0.8
0.55
0.55
DQ output access time from CK/CK
− 0.75 + 0.75
− 0.75 + 0.75
− 0.8
− 0.8
0.45
0.45
ns
ns
tCK
tCK
ns
ns
ns
ns
ns
1-4
1-4
1-4
1-4
1-4
1-4
1-4
1-4
1-4
tDQSCK DQS output access time from CK/CK
tCH
tCL
tHP
tCK
tCK
tDH
tDS
CK high-level width
CK low-level width
Clock Half Period
0.45
0.45
0.55
0.55
min (tCL, tCH)
min (tCL, tCH)
min (tCL, tCH)
CL = 2.5
CL = 2.0
6
12
12
7
12
12
8
12
12
Clock cycle time
7.5
7.5
0.5
0.5
10
0.6
0.6
DQ and DM input hold time
DQ and DM input setup time
0.45
0.45
–
–
Control and Addr. input pulse width (each
input)
tIPW
2.2
2.2
2.5
2
ns
ns
1, 10
1-4,
11
tDIPW DQ and DM input pulse width (each input)
1.75
1.75
tHZ
tLZ
Data-out high-impedence time from CK/CK
Data-out low-impedence time from CK/CK
− 0.7
− 0.7
0.75
+ 0.7
+ 0.7
1.25
− 0.75 + 0.75
− 0.75 + 0.75
− 0.8
− 0.8
0.75
+ 0.8
+ 0.8
1.25
ns
ns
tCK
1-4, 5
1-4, 5
1-4
tDQSS Write command to 1st DQS latching transition
0.75
1.25
+ 0.5
DQS-DQ skew
tDQSQ
+ 0.4
+ 0.6
ns
1-4
(for DQS & associated DQ signals)
tQHS
tQH
Data hold skew factor
+ 0.55
tHP-tQHS
0.35
–
+ 0.75
+ 1.0
ns
ns
tCK
1-4
1-4
1-4
Data Output hold time from DQS
tHP-tQHS
0.35
tHP-tQHS
0.35
tDQSL,H DQS input low (high) pulse width (write cycle)
DQS falling edge to CK setup time (write
tDSS
0.2
0.2
0.2
0.2
0.2
0.2
tCK
tCK
1-4
1-4
cycle)
DQS falling edge hold time from CK (write
cycle)
tDSH
tMRD Mode register set command cycle time
tWPRES Write preamble setup time
tWPST Write postamble
12
0
14
0
16
0
ns
ns
tCK
tCK
ns
ns
ns
ns
tCK
tCK
ns
ns
1-4
1-4, 7
1-4, 6
1-4
0.40
0.25
0.75
0.60
0.40
0.25
0.9
1.0
0.9
1.0
0.9
0.40
45
0.60
0.40
0.25
1.1
1.1
1.1
1.1
0.9
0.40
50
0.60
tWPRE Write preamble
fast slew rate
Address and control
tIS
input setup time
slow slew rate
2-4,
10,11
fast slew rate
0.75
Address and control
tIH
input hold time
slow slew rate
tRPRE Read preamble
tRPST Read postamble
0.9
0.40
42
1.1
0.60
1.1
0.60
1-4
1-4
1-4
1-4
tRAS
tRC
Active to Precharge command
120,000
120,000
Active to Active/Auto-refresh command period
60
65
70
INFINEON Technologies
13
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Electrical Characteristics & AC Timing for DDR-I components
(for reference only)
(0 °C ≤ TA ≤ 70 °C; VDDQ = 2.5V ± 0.2V; VDD = 2.5V ± 0.2V)
DDR333
-6
DDR266A
-7
DDR200
-8
Symbol
Parameter
Unit Notes
Min
72
Max
Min
Max
Min
Max
Auto-refresh to Active/Auto-refresh
command period
tRFC
75
80
ns
1-4
tRCD
tRP
tRRD
tWR
Active to Read or Write delay
Precharge command period
Active bank A to Active bank B command
Write recovery time
18
18
12
15
20
20
15
15
20
20
15
15
ns
ns
ns
ns
1-4
1-4
1-4
1-4
(twr/tck)
+ (trp/
tck)
(twr/tck)
+ (trp/
tck)
Auto precharge write recovery
+ precharge time
tDAL
tCK
1-4,9
tWTR Internal write to read command delay
tXSNR Exit self-refresh to non-read command
tXSRD Exit self-refresh to read command
Average Periodic
1
1
1
tCK
ns
tCK
1-4
1-4
1-4
75
75
80
200
200
200
tREFI
7.8
7.8
7.8
µs
1-4, 8
512 Mbit based
Refresh Interval
1. Input slew rate >=1V/ns for DDR266 and = 1V/ns for DDR200.
2. The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross: the input reference
level for signals other than CK/CK, is VREF. CK/CK slew rate are >= 1.0 V/ns.
3. Inputs are not recognized as valid until VREF stabilizes.
4. The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (Note 3) is VTT
5. HZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referred
to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ).
.
t
6. The maximum limit for this parameter is not a device limit. The device operates with a greater value for this parameter, but
system performance (bus turnaround) degrades accordingly.
7. The specific requirement is that DQS be valid (HIGH, LOW, or some point on a valid transition) on or before this CK edge.
A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were
previously in progress on the bus, DQS will be transitioning from Hi-Z to logic LOW. If a previous write was in progress,
DQS could be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS
.
8. A maximum of eight Autorefresh commands can be posted to any given DDR SDRAM device.
9. For each of the terms, if not already an integer, round to the next highest integer. tCK is equal to the actual system clock
cycle time.
10. These parameters guarantee device timing, but they are not necessarily tested on each device
11. Fast slew rate >= 1.0 V/ns , slow slew rate >= 0.5 V/ns and < 1V/ns for command/address and CK & CK slew rate >1.0 V/
ns, measured between VOH(ac) and VOL(ac)
INFINEON Technologies
14
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
SPD Codes for PC1600 Modules “-8”
512MB
x64
1bank
-8
512MB
x72
1bank
-8
1GB
x64
2bank
-8
1GB
x72
2bank
-8
Byte#
Description
HEX
80
HEX
80
HEX
80
HEX
80
0
1
Number of SPD Bytes
128
Total Bytes in Serial PD
Memory Type
256
08
08
08
08
2
DDR-SDRAM
07
07
07
07
3
Number of Row Addresses
Number of Column Addresses
Number of DIMM Banks
13
0D
0B
0D
0B
0D
0B
02
0D
0B
02
4
11
5
1 / 2
01
01
6
Module Data Width
x64 / x72
40
48
40
48
7
Module Data Width (cont’d)
Module Interface Levels
0
SSTL_2.5
8 ns
00
00
00
00
8
04
04
04
04
9
SDRAM Cycle Time at CL = 2.5
Access Time from Clock at CL = 2.5
DIMM Config
80
80
80
80
10
11
12
13
14
0.8 ns
80
80
80
80
non-ECC / ECC
Self-Refresh, 7.8 ms
x8
00
02
00
02
Refresh Rate/Type
82
82
82
82
SDRAM Width, Primary
08
08
08
08
Error Checking SDRAM Data Width
Minimum Clock Delay for Back-to-Back
Random Column Address
Burst Length Supported
na / x8
00
08
00
08
15
tccd = 1 CLK
01
01
01
01
16
17
2, 4 & 8
0E
04
0E
04
0E
04
0E
04
Number of SDRAM Banks
Supported CAS Latencies
CS Latencies
4
18
CAS latency = 2 & 2.5
0C
01
0C
01
0C
01
0C
01
19
CS latency = 0
20
WE Latencies
Write latency = 1
02
02
02
02
21
SDRAM DIMM Module Attributes
SDRAM Device Attributes: General
Min. Clock Cycle Time at CAS Latency = 2
Access Time from Clock for CL = 2
Minimum Clock Cycle Time at CL = 1.5
Access Time from Clock at CL = 1.5
Minimum Row Precharge Time
Minimum Row Act. to Row Act. Delay tRRD
Minimum RAS to CAS Delay tRCD
Minimum RAS Pulse Width tRAS
Module Bank Density (per bank)
Addr. and Command Setup Time
Addr. and Command Hold Time
Data Input Setup Time
unbuffered
20
20
20
20
22
–
C0
A0
C0
A0
C0
A0
C0
A0
23
10.0 ns
24
0.8 ns
80
80
80
80
25
not supported
00
00
00
00
26
not supported
00
00
00
00
27
20 ns
50
50
50
50
28
15 ns
3C
50
3C
50
3C
50
3C
50
29
20 ns
30
50 ns
32
32
32
32
31
512MByte
80
80
80
80
32
1.1 ns
B0
B0
B0
B0
33
1.1 ns
B0
B0
B0
B0
34
0.6 ns
60
60
60
60
35
Data Input Hold Time
0.6 ns
60
60
60
60
36-40
41
Superset Information
–
00
00
00
00
Minimum Core Cycle Time tRC
Min. Auto Refresh Cmd Cycle Time tRFC
Maximum Clock Cycle Time tck
Max. DQS-DQ Skew tDQSQ
X-Factor tQHS
70 ns
46
46
46
46
42
80 ns
50
50
50
50
43
12 ns
30
30
30
30
44
0.6 ns
3C
A0
3C
A0
3C
A0
3C
A0
45
1.0 ns
46-61
62
Superset Information
-
00
00
00
00
SPD Revision
Revision 0.0
00
00
00
00
63
Checksum for Bytes 0 - 62
Manufacturers JEDEC ID Code
Manufacturer
–
–
–
–
–
–
–
–
–
E8
FA
C1
INFINEON
E9
FB
C1
INFINEON
64
C1
INFINEON
C1
INFINEON
65-71
72
Module Assembly Location
Module Part Number
73-90
91-92
93-94
95-98
99-127
Module Revision Code
Module Manufacturing Date
Module Serial Number
–
128-255
open for Customer use
–
INFINEON Technologies
15
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
SPD Codes for PC2100 & PC2700 Modules “-7” & “-6”
512MB
512MB
x72
1bank
-7
1GB
x64
2bank
-7
1GB
x72
2bank
-7
1GB
x64
2bank
-6
1GB
x72
2bank
-6
x64
1bank
-7
Byte#
Description
HEX
80
HEX
80
HEX
80
HEX
80
HEX
80
HEX
80
0
1
Number of SPD Bytes
128
Total Bytes in Serial PD
Memory Type
256
08
08
08
08
08
08
2
DDR-SDRAM
07
07
07
07
07
07
3
Number of Row Addresses
Number of Column Addresses
Number of DIMM Banks
13
0D
0B
01
0D
0B
0D
0B
02
0D
0B
02
0D
0B
0D
0B
02
4
11
5
1 / 2
x64 / x72
0
01
02
6
Module Data Width
40
48
40
48
40
48
7
Module Data Width (cont’d)
Module Interface Levels
00
00
00
00
00
00
8
SSTL_2.5
7 ns
04
04
04
04
04
04
9
SDRAM Cycle Time at CL = 2.5
Access Time from Clock at CL = 2.5
DIMM Config
70
70
70
70
60
60
10
11
12
13
14
0.75 ns
75
75
75
75
70
70
non-ECC / ECC
Self-Refresh, 7.8 ms
x8
00
02
00
02
00
02
Refresh Rate/Type
82
82
82
82
82
82
SDRAM Width, Primary
08
08
08
08
08
08
Error Checking SDRAM Data Width
Minimum Clock Delay for Back-to-Back
Random Column Address
Burst Length Supported
na / x8
00
08
00
08
00
08
15
tccd = 1 CLK
01
01
01
01
01
01
16
17
2, 4 & 8
0E
04
0E
04
0E
04
0E
04
0E
04
0E
04
Number of SDRAM Banks
Supported CAS Latencies
CS Latencies
4
CAS latency = 2 & 2.5
CS latency = 0
Write latency = 1
unbuffered
–
18
0C
01
0C
01
0C
01
0C
01
0C
01
0C
01
19
20
WE Latencies
02
02
02
02
02
02
21
SDRAM DIMM Module Attributes
SDRAM Device Attributes: General
Min. Clock Cycle Time at CAS Latency = 2
Access Time from Clock for CL = 2
Minimum Clock Cycle Time at CL = 1.5
Access Time from Clock at CL = 1.5
Minimum Row Precharge Time
Minimum Row Act. to Row Act. Delay tRRD
Minimum RAS to CAS Delay tRCD
Minimum RAS Pulse Width tRAS
Module Bank Density (per bank)
Addr. and Command Setup Time
Addr. and Command Hold Time
Data Input Setup Time
20
20
20
20
20
20
22
C0
75
C0
75
C0
75
C0
75
C0
75
C0
75
23
7.5 ns
24
0.75 ns
not supported
not supported
20 ns
75
75
75
75
70
70
25
00
00
00
00
00
00
26
00
00
00
00
00
00
27
50
50
50
50
48
48
28
15 ns
3C
50
3C
50
3C
50
3C
50
30
30
29
20 ns
48
48
30
45 ns
2D
80
2D
80
2D
80
2D
80
2A
80
2A
80
31
512MByte
0.9 ns
32
90
90
90
90
75
75
33
0.9 ns
90
90
90
90
75
75
34
0.5 ns
50
50
50
50
45
45
35
Data Input Hold Time
0.5 ns
50
50
50
50
45
45
36-40
41
Superset Information
–
00
00
00
00
00
00
Minimum Core Cycle Time tRC
Min. Auto Refresh Cmd Cycle Time tRFC
Maximum Clock Cycle Time tck
Max. DQS-DQ Skew tDQSQ
X-Factor tQHS
65 ns
41
41
41
41
3C
48
3C
48
42
75 ns
4B
30
4B
30
4B
30
4B
30
43
12 ns
30
30
44
0.5 ns
32
32
32
32
2D
55
2D
55
45
0.75 ns
–
75
75
75
75
46-61
62
Superset Information
00
00
00
00
00
00
SPD Revision
Revision 0.0
–
00
00
00
00
00
00
63
Checksum for Bytes 0 - 62
Manufacturers JEDEC ID Code
F3
05
F4
06
42
54
64
–
C1
INFI-
NEON
C1
INFI-
NEON
C1
INFI-
NEON
C1
INFI-
NEON
C1
INFI-
NEON
C1
INFI-
NEON
65-71
Manufacturer
–
72
Module Assembly Location
Module Part Number
Module Revision Code
Module Manufacturing Date
Module Serial Number
–
–
–
–
–
–
–
73-90
91-92
93-94
95-98
99-127
128-255
open for Customer use
–
INFINEON Technologies
16
2002-09-10 (rev.0.81)
HYS64/72D64000/128020GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Package Outlines -Raw Card A1 (One Bank Modules)
DDR-SDRAM DIMM Module Package
+ 0.15
-
133.35
4.0 max.
Front View
4.0
*)
53
92
52
pin 1
+ 0.1
-
1.27
64.77
49.53
2.3 typ.
6.62
Backside View
144
pin 93
145
184
2.5D
3
3
*) on ECC modules only
Detail of Contacts B
6.35
Detail of Contacts A
0.9R
+ 0.05
-
1
1.27
1.8
2.175
L-DIM-184-
29
INFINEON Technologies
17
2002-09-10 (rev.0.81)
HYS64/72D64000/128x20GU-7/8-A
Unbuffered DDR-I SDRAM-Modules
Package Outlines - Raw Card B1 (Two Bank Modules)
DDR-SDRAM DIMM Module Package
two bank modules
+ 0.15
-
133.35
4.0 max.
Front View
4.0
*)
92
53
52
pin 1
+ 0.1
-
1.27
64.77
49.53
2.3 typ.
6.62
Backside View
144
pin 93
145
184
2.5D
*)
3
3
*) on ECC modules only
Detail of Contacts A
Detail of Contacts B
6.35
0.9R
+ 0.05
-
1
1.27
1.8
2.175
L-DIM-184-
9d
INFINEON Technologies
18
2002-09-10 (rev.0.81)
相关型号: