K0890NC400 [IXYS]
Silicon Controlled Rectifier, 1755A I(T)RMS, 4000V V(DRM), 4000V V(RRM), 1 Element;型号: | K0890NC400 |
厂家: | IXYS CORPORATION |
描述: | Silicon Controlled Rectifier, 1755A I(T)RMS, 4000V V(DRM), 4000V V(RRM), 1 Element 栅 栅极 |
文件: | 总11页 (文件大小:220K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Date:- 4 Sep, 2002
WESTCODE
Data Sheet Issue:- 1
An IXYS Company
Medium Voltage Thyristor
Types K0890NC360 to K0890NC400
Old Type No.: R295CH36-40
Absolute Maximum Ratings
MAXIMUM
LIMITS
VOLTAGE RATINGS
UNITS
VDRM
VDSM
VRRM
VRSM
Repetitive peak off-state voltage, (note 1)
Non-repetitive peak off-state voltage, (note 1)
Repetitive peak reverse voltage, (note 1)
Non-repetitive peak reverse voltage, (note 1)
3600-4000
3600-4000
3600-4000
3700-4100
V
V
V
V
MAXIMUM
LIMITS
OTHER RATINGS
UNITS
IT(AV)M
IT(AV)M
IT(AV)M
IT(RMS)
IT(d.c.)
ITSM
Maximum average on-state current, Tsink=55°C, (note 2)
Maximum average on-state current. Tsink=85°C, (note 2)
Maximum average on-state current. Tsink=85°C, (note 3)
Nominal RMS on-state current, Tsink=25°C, (note 2)
D.C. on-state current, Tsink=25°C, (note 4)
Peak non-repetitive surge tp=10ms, Vrm=0.6VRRM, (note 5)
Peak non-repetitive surge tp=10ms, Vrm≤10V, (note 5)
I2t capacity for fusing tp=10ms, Vrm=0.6VRRM, (note 5)
I2t capacity for fusing tp=10ms, Vrm≤10V, (note 5)
Critical rate of rise of on-state current (repetitive), (Note 6)
Critical rate of rise of on-state current (non-repetitive), (Note 6)
Peak reverse gate voltage
890
610
A
A
365
A
1755
1525
10.9
A
A
kA
kA
A2s
A2s
A/µs
A/µs
V
ITSM2
I2t
I2t
12
594×103
720×103
500
(di/dt)cr
1000
5
VRGM
PG(AV)
PGM
Mean forward gate power
2
W
Peak forward gate power
30
W
Tj op
Operating temperature range
-40 to +125
-40 to +150
°C
°C
Tstg
Storage temperature range
Notes:-
1) De-rating factor of 0.13% per °C is applicable for Tj below 25°C.
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 125°C Tj initial.
6) VD=67% VDRM, IFG=2A, tr≤0.5µs, Tcase=125°C.
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 1 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Characteristics
PARAMETER
MIN.
TYP. MAX. TEST CONDITIONS (Note 1)
UNITS
VTM
VT0
rT
Maximum peak on-state voltage
Threshold voltage
-
-
2.98 ITM=1830A
V
V
-
-
1.516
0.8
Slope resistance
-
-
mΩ
V/µs
mA
mA
V
(dv/dt)cr Critical rate of rise of off-state voltage
1000
-
-
VD=80% VDRM, linear ramp, gate o/c
IDRM
IRRM
Vtr
Peak off-state current
Peak reverse current
On-state recovery voltage
Gate trigger voltage
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
100 Rated VDRM
100 Rated VRRM
6.0
-
-
IT=2500A, tp=10ms, Tcase=25°C
VGT
IGT
VGD
IH
3.0
300
V
Tj=25°C VD=10V, IT=3A
Gate trigger current
-
mA
V
Gate non-trigger voltage
Holding current
-
0.25 Rated VDRM
1000 Tj=25°C
1.0
-
mA
µs
tgd
Gate-controlled turn-on delay time
Turn-on time
0.5
1.5
4000
1500
100
25
VD=67% VDRM, IT=1000A, di/dt=10A/µs,
I
FG=2A, tr=0.5µs, Tj=25°C
tgt
3.0
µs
Qrr
Qra
Irm
Recovered charge
-
µC
µC
A
Recovered charge, 50% Chord
Reverse recovery current
Reverse recovery time
1750
I
TM=1000A, tp=1000µs, di/dt=10A/µs,
Vr=50V
-
-
trr
µs
ITM=1000A, tp=1000µs, di/dt=10A/µs,
Vr=50V, Vdr=80%VDRM, dVdr/dt=20V/µs
ITM=1000A, tp=1000µs, di/dt=10A/µs,
Vr=50V, Vdr=80%VDRM, dVdr/dt=200V/µs
-
-
300
500
-
-
tq
Turn-off time
µs
-
-
-
0.024 Double side cooled
K/W
K/W
kN
RthJK
Thermal resistance, junction to heatsink
-
-
0.048 Single side cooled
F
Mounting force
Weight
19
-
26
-
Wt
510
g
Notes:-
1) Unless otherwise indicated Tj=125°C.
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 2 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Notes on Ratings and Characteristics
1.0 Voltage Grade Table
V
DRM VDSM VRRM
VRSM
V
3700
3850
4100
VD VR
DC V
1900
1960
2000
Voltage Grade
V
36
38
40
3600
3800
4000
2.0 Extension of Voltage Grades
This report is applicable to other voltage grades when supply has been agreed by Sales/Production.
3.0 De-rating Factor
A blocking voltage de-rating factor of 0.13%/°C is applicable to this device for Tj below 25°C.
4.0 Repetitive dv/dt
Standard dv/dt is 1000V/µs.
5.0 Frequency Ratings
The curves illustrated in figures 17 & 18 are for guidance only and are superseded by the maximum
ratings shown on page 1. For operation above line frequency, please consult the factory for assistance.
6.0 Snubber Components
When selecting snubber components, care must be taken not to use excessively large values of snubber
capacitor or excessively small values of snubber resistor. Such excessive component values may lead to
device damage due to the large resultant values of snubber discharge current. If required, please consult
the factory for assistance.
7.0 Rate of rise of on-state current
The maximum un-primed rate of rise of on-state current must not exceed 1000A/µs at any time during
turn-on on a non-repetitive basis. For repetitive performance, the on-state rate of rise of current must not
exceed 500A/µs at any time during turn-on. Note that these values of rate of rise of current apply to the
total device current including that from any local snubber network.
8.0 Square wave frequency ratings
These ratings are given for load component rate of rise of on-state current of 50A/µs.
9.0 Duty cycle lines
The 100% duty cycle is represented on the frequency ratings by a straight line. Other duties can be
included as parallel to the first.
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 3 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
10.0 Gate Drive
The nominal requirement for a typical gate drive is illustrated below. An open circuit voltage of at least 30V
is assumed. This gate drive must be applied when using the full di/dt capability of the device.
IGM
4A/µs
IG
tp1
The magnitude of IGM should be between five and ten times IGT, which is shown on page 2. Its duration
(tp1) should be 20µs or sufficient to allow the anode current to reach ten times IL, whichever is greater.
Otherwise, an increase in pulse current could be needed to supply the necessary charge to trigger. The
‘back-porch’ current IG should remain flowing for the same duration as the anode current and have a
magnitude in the order of 1.5 times IGT.
11.0 Computer Modelling Parameters
11.1 Device Dissipation Calculations
∆T
2
WAV =
−VT 0 + VT 0 + 4 ff r WAV
T
Rth
IAV =
and:
2 ff r
T
∆T = Tj max −THs
Where VT0=1.516V, rT=0.8mΩ,
Rth = Supplementary thermal impedance, see table below and
ff = Form factor, see table below.
Supplementary Thermal Impedance
Conduction Angle
30°
60°
90°
120°
180°
270°
d.c.
Square wave Double Side Cooled
Square wave Single Side Cooled
Sine wave Double Side Cooled
Sine wave Single Side Cooled
0.0293
0.0534
0.0286
0.0531
0.0285
0.053
0.0278
0.0524
0.0269
0.0517
0.0271
0.0518
0.0263
0.0511
0.0261
0.0509
0.0248
0.0497
0.0249
0.0497
0.024
0.048
0.0276
0.0523
Form Factors
Conduction Angle
Square wave
Sine wave
30°
60°
90°
2
120°
1.732
1.879
180°
1.414
1.57
270°
d.c.
1
3.464
3.98
2.449
2.778
1.149
2.22
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 4 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
11.2 Calculating VT using ABCD Coefficients
The on-state characteristic IT vs. VT, on page 6 is represented in two ways;
(i)
(ii)
the well established VT0 and rT tangent used for rating purposes and
a set of constants A, B, C, D, forming the coefficients of the representative equation for VT in
terms of IT given below:
VT = A + B ln
(
IT + C IT + D IT
)
The constants, derived by curve fitting software, are given below for both hot and cold characteristics. The
resulting values for VT agree with the true device characteristic over a current range, which is limited to
that plotted.
25°C Coefficients
125°C Coefficients
A
B
C
D
0.78163983
0.4140327
1.11101×10-3
A
B
C
D
0.66032723
0.169496
8.46556×10-4
-0.0744794
-0.01175336
11.3 D.C. Thermal Impedance Calculation
p=n
−t
τ p
r = r 1− e
∑
t
p
p=1
Where p = 1 to n, n is the number of terms in the series and:
t = Duration of heating pulse in seconds.
rt
= Thermal resistance at time t.
rp = Amplitude of pth term.
τp = Time Constant of rth term.
The coefficients for this device are shown in the tables below:
D.C. Double Side Cooled
Term
rp
1
2
3
4
5
0.01249139
0.8840810
6.316833×10-3
1.850855×10-3
1.922045×10-3
6.135330×10-4
0.1215195
0.03400152
6.742908×10-3
1.326292×10-3
τp
D.C. Single Side Cooled
Term
rp
1
2
3
4
5
6
0.02919832
6.298105
4.863568×10-3 3.744798×10-3 6.818034×10-3 2.183558×10-3 1.848294×10-3
3.286174
0.5359179
0.1186897
0.02404574
3.379476×10-3
τp
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 5 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Curves
Figure 1 - On-state characteristics of Limit device
Figure 2 - Transient thermal impedance
10000
0.1
SSC 0.048K/W
Tj = 25°C
Tj = 125°C
DSC 0.024K/W
0.01
1000
0.001
0.0001
K0890NC360-400
Issue 1
K0890NC360-400
Issue 1
100
0.00001
0
2
4
6
8
10
0.0001 0.001
0.01
0.1
1
10
100
Instantaneous on-state voltage - VT (V)
Time (s)
Figure 3 - Gate characteristics - Trigger limits
Figure 4 - Gate characteristics - Power curves
20
6
K0890NC360-400
K0890NC360-400
Issue 1
Issue 1
Tj=25°C
Tj=25°C
18
5
16
14
Max VG dc
4
Max VG dc
12
10
8
IGT, VGT
3
PG Max 30W dc
2
1
6
4
PG 2W dc
2
IGD, VGD
Min VG dc
Min VG dc
0
0
0
2
4
6
8
10
0
0.2
0.4
0.6
0.8
1
Gate Trigger Current - IGT (A)
Gate Trigger Current - IGT (A)
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 6 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Figure 5 - Total recovered charge, Qrr
Figure 6 - Recovered charge, Qra (50% chord)
10000
10000
2000A
1500A
1000A
500A
2000A
1500A
1000A
500A
Tj = 125°C
Tj = 125°C
K0890NC360-400
Issue 1
K0890NC360-400
Issue 1
1000
1000
1
10
100
1000
1
10
100
1000
Commutation rate - di/dt (A/µs)
Commutation rate - di/dt (A/µs)
Figure 7 - Peak reverse recovery current, Irm
Figure 8 - Maximum recovery time, trr (50% chord)
100
10000
2000A
1500A
1000A
500A
1000
100
10
10
2000A
1500A
1000A
500A
Tj = 125°C
Tj = 125°C
K0890NC360-400
Issue 1
K0890NC360-400
Issue 1
1
1
10
100
1000
1
10
100
1000
Commutation rate - di/dt (A/µs)
Commutation rate - di/dt (A/µs)
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 7 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Figure 9 – On-state current vs. Power dissipation –
Double Side Cooled (Sine wave)
Figure 10 – On-state current vs. Heatsink
temperature - Double Side Cooled (Sine wave)
4000
125
K0890NC360-400
Issue 1
180°
3500
3000
2500
2000
1500
1000
500
120°
90°
60°
30°
100
75
50
25
30°
60°
90° 120° 180°
K0890NC360-400
Issue 1
0
0
0
200
400
600
800
1000
1200
0
200
400
600
800
1000
1200
Mean forward current (A) (Whole cycle averaged)
Mean forward current (A) (Whole cycle averaged)
Figure 11 – On-state current vs. Power dissipation
– Double Side Cooled (Square wave)
Figure 12 – On-state current vs. Heatsink
temperature – Double Side Cooled (Square wave)
4000
125
K0890NC360-400
Issue 1
3500
100
3000
d.c.
270°
180°
120°
2500
2000
1500
1000
500
75
90°
60°
30°
50
25
30°
60° 90°120° 180°
270° d.c.
K0890NC360-400
Issue 1
0
0
0
500
1000
1500
0
500
1000
1500
Mean Forward Current (Amps) (Whole Cycle Averaged)
Mean Forward Current (Amps) (Whole Cycle Averaged)
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 8 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Figure 13 – On-state current vs. Power dissipation
– Single Side Cooled (Sine wave)
Figure 14 – On-state current vs. Heatsink
temperature – Single Side Cooled (Sine wave)
2000
125
K0890NC360-400
Issue 1
180°
1800
1600
1400
1200
1000
800
600
400
200
0
120°
90°
60°
30°
100
75
50
25
30°
60°
90° 120° 180°
K0890NC360-400
Issue 1
0
0
100
200
300
400
500
600
700
0
100
200
300
400
500
600
700
Mean forward current (A) (Whole cycle averaged)
Mean forward current (A) (Whole cycle averaged)
Figure 15 – On-state current vs. Power dissipation
– Single Side Cooled (Square wave)
Figure 16 – On-state current vs. Heatsink
temperature – Single Side Cooled (Square wave)
125
2000
1800
1600
1400
1200
K0890NC360-400
Issue 1
100
75
d.c.
270°
1000
800
600
400
200
0
180°
120°
90°
60°
30°
50
25
30°
60° 90° 120° 180° 270° d.c.
K0890NC360-400
Issue 1
0
0
200
400
600
800
1000
0
200
400
600
800
1000
Mean Forward Current (Amps) (Whole Cycle Averaged)
Mean Forward Current (Amps) (Whole Cycle Averaged)
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 9 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Figure 17 – Square Wave Frequency Ratings
Figure 18 – Sine Wave Frequency Ratings
1.00E+05
1.00E+05
K0890NC360-400
Issue 1
THs=55°C
500A
1kA
100% Duty Cycle
500A
100% Duty Cycle
1.00E+04
1.00E+03
1.00E+02
1.00E+01
1.00E+00
1kA
1.00E+04
1.00E+03
1.00E+02
1.00E+01
1.5kA
2kA
1.5kA
2kA
3kA
5kA
3kA
5kA
THs=55°C
di/dt=50A/µs
K0890NC360-400
Issue 1
1.00E-05
1.00E-04
1.00E-03
1.00E-02
1.00E-05
1.00E-04
1.00E-03
1.00E-02
Pulse width (s)
Pulse Width (s)
Figure 19 - Maximum surge and I2t Ratings
Gate may temporarily lose control of conduction angle
100000
10000
1000
1.00E+07
I2t: VRRM≤10V
I2t: 60% VRRM
1.00E+06
ITSM: VRRM≤10V
ITSM: 60% VRRM
Tj (initial) = 125°C
K0890NC360-400
Issue 1
1.00E+05
1
3
5
10
1
5
10
50 100
Duration of surge (ms)
Duration of surge (cycles @ 50Hz)
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 10 of 11
September, 2002
WESTCODE An IXYS Company
Medium Voltage Thyristor Types K0890NC360 to K0890NC400
Outline Drawing & Ordering Information
ORDERING INFORMATION
(Please quote 10 digit code as below)
ꢀꢀ
K0890
NC
0
Voltage code
Fixed turn-off
VDRM/100
time code
36-40
Fixed
Type Code
Fixed
outline code
Order code: K0890NC380 – 3800V VRRM, 27.7mm clamp height capsule.
IXYS Semiconductor GmbH
Edisonstraße 15
Westcode Semiconductors Ltd
PO Box 57 Chippenham
D-68623 Lampertheim
Tel: +49 6206 503-0
Fax: +49 6206 503-627
E-mail: marcom@ixys.de
Wiltshire SN15 1JL
Tel: +44 (0)1249 444524
Fax: +44 (0)1249 659448
E-mail: WSL.sales@westcode,com
WESTCODE
An IXYS Company
IXYS Corporation
3540 Bassett Street
Santa Clara CA 95054 USA
Tel: +1 (408) 982 0700
Fax: +1 (408) 496 0670
E-mail: sales@ixys.net
Westcode Semiconductors Inc
3270 Cherry Avenue
Long Beach CA 90807 USA
Tel: +1 (562) 595 6971
Fax: +1 (562) 595 8182
E-mail: WSI.sales@westcode.com
www.westcode.com
www.ixys.net
The information contained herein is confidential and is protected by Copyright. The information may not be used or
© Westcode Semiconductors Ltd.
disclosed except with the written permission of and in the manner permitted by the proprietors Westcode Semiconductors
Ltd.
In the interest of product improvement, Westcode reserves the right to change specifications at any time without prior
notice.
Devices with a suffix code (2-letter or letter/digit/letter combination) added to their generic code are not necessarily subject
to the conditions and limits contained in this report.
Data Sheet. Types K0890NC360 to K0890NC400 Issue 1
Page 11 of 11
September, 2002
相关型号: