COMMUNICATIONS MODULES & SUBSYSTEMS  
Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol,  
CWDM, 3R Transponder  
WaveReady™ Transponder 740 LR CWDM  
Key Features  
• Client-side SFP modules support either single-mode (SMF)  
or multi-mode fiber (MMF)  
• Automatic bit rate detection and reporting  
• Multiple protocols supported at discrete bit rates of 125 Mb/s  
to 2.7 Gb/s  
• Network optics support eight CWDM channels using 20-nm  
channel spacing  
• Facility loopback functionality on both network and client sides  
• Remote management with SNMP traps or TL1  
• 3R functionality at all supported bit rates and protocols  
Applications  
The WaveReady Transponder 740 LR CWDM (WRT-740 CWDM) is a multi-rate,  
multi-protocol, auto-lock module that translates optical signals between a variety  
of client-side interfaces into a long-reach, single-mode course wavelength division  
multiplexing (CWDM) interface. This module features small form factor  
pluggable (SFP) modules on the client side as well as loopback and 3R (reshape,  
re-time, and re-amplify/regenerate) functionalities.  
Wavelength services  
• Metro optical access overlay  
• Storage area network (SAN) and  
GigE extension services  
The WRT-740 CWDM contains an embedded management channel, which  
allows for remote management, lowering operating, administration, and  
management costs. The transponder’s WaveReady communication module  
manages the WRT-740 CWDM using TL1, SNMP, command line interface, or  
JDSU Node Manager software  
Compliance  
• FCC Part 15 (Class A)  
• UL 60950 3rd edition, December 2000  
• CAN/CSA-C22.2 No. 950-95  
• NEBS Level 3  
• GR-63-CORE  
• CE  
• IEC 60950  
• ETS300-386  
• EN 55022 (Class B)  
• 73/23/EEC  
NORTH AMERICA: 800 498-JDSU (5378)  
WORLDWIDE: +800 5378-JDSU  
WEBSITE: www.jdsu.com  
WAVEREADY TRANSPONDER 740 LR CWDM  
2
Point-to-Point Eight-Channel CWDM Link  
Typical Link Budget  
Data Rate  
Minimum Rx Power  
Total Power Budget  
Maximum Distance  
OC-48  
Gigabit Ethernet  
-28.5 dBm  
-30 dBm  
27.5 dB  
29.0 dB  
76 km  
82 km  
WAVEREADY TRANSPONDER 740 LR CWDM  
3
Point-to-Point Single-Channel CWDM Link  
Note: Power budget is 25 dB, but to go from 80 to 100 km, a dispersion compensation module (DCM) is required.  
Typical Link Budget  
Data Rate  
Minimum Rx Power  
Total Power Budget  
Maximum Distance  
OC-48  
Gigabit Ethernet  
-28.5 dBm  
-30 dBm  
27.5 dB  
29.0 dB  
110 km  
116 km  
Network Optical Specifications  
Parameter  
Specifications  
Optical Path between Transmitter and Receiver Connectors  
Dispersion penalty at OC-48 (80 km)  
Dispersion at OC-48  
Optical return loss of cable plant, including any connectors  
Discrete reflectance between transmitter and receiver connectors  
Maximum link budget at OC-48,  
including dispersion penalty at BER = 1x10-12  
Transmitter  
Maximum 2 dB  
Minimum 1600 ps/nm  
Minimum 24 dB  
Maximum 27 dB  
Minimum 25.5 dB  
Typical  
27 dB  
Output wavelengths  
Wavelength accuracy  
1471, 1491, 1511, 1531, 1551, 1571, 1591, and 1611 nm  
6.5 nm  
Mean output power  
Minimum -1 dBm  
Typical 1 dBm  
Maximum 4 dBm  
Minimum 8.2 dB1  
Extinction ratio  
Receiver  
Sensitivity at 100Base-F to GigE, BER = 1x10-12  
Sensitivity at OC-48, BER = 1x10-12  
Overload  
Minimum -30 dBm  
Minimum -28.5 dBm  
Minimum -8 dBm2  
LOS activation threshold  
LOS deactivation threshold  
Typical  
Typical  
-36 dBm  
-34 dBm  
Note: All specifications are guaranteed over the life, operating temperatures, wavelengths, and input voltage range specified. This product should be deployed in accordance  
with each company’s deployment directives.  
1. At OC-48  
2. Management communications at OC-3 require input power less than -15 dBm  
WAVEREADY TRANSPONDER 740 LR CWDM  
4
Other Specifications  
Parameter  
Condition  
Specifications  
Electrical  
Power dissipation  
Over temperature range EOL  
Typical  
15.5 W  
19 W  
38 V  
Maximum  
Minimum  
Maximum  
Supply voltage1  
60 V  
Environmental  
Storage temperature  
Ambient operating temperature  
-40 to 85°C  
-5 to 55 °C  
-5 to 55°C short term; 96 hours continuous;  
no more than 15 days per year  
Non-condensing  
Humidity  
5 to 95%  
Mechanical  
Weight (approximate)  
Dimensions (H x W x D)  
1.4 kg (3.1 lb)  
25.4 x 223.5 x 175 mm  
(1.0 x 6.89 x 8.8 inches)  
WaveReady 3500-F or WaveReady  
3100 shelf in standard 19- or  
23-inch or ETSI rack  
Mounting options  
1. The DC power supply must be -48 V SELV output and certified by a nationally recognized test laboratory (NRTL). UL tested at -48 V.  
Interface Specifications  
Parameter  
Specification  
Operations, administration, maintenance,  
and provisioning (OAM&P)  
Via the WaveReady Communication Module 200; remote management:  
SNMP and TL1 command mode through JDSU Node Manager software or  
through telnet or command-line application or SNMP; Communication  
with remote modules through an embedded supervisory channel  
CARD (power), MAJ/CRIT (major/critical alarm), MIN (minor alarm),  
LOS B, LOS D, LOOPBK (loopback), MGT (management)  
Client-side ports: A and B single-mode or multi-mode fiber (SMF or MMF);  
Network-side ports: C and D, SMF  
CARD (power), MAJ/CRIT (major/critical) alarm; MIN (minor alarm),  
LOS B, LOS D (loss of lock); Alarm relay open under normal operation;  
relay closed when power is off and alarm is active  
Front panel LEDs  
Front panel ports  
Alarms  
WAVEREADY TRANSPONDER 740 LR CWDM  
Ordering Information  
For more information on this or other products and their availability, please contact your local JDSU account manager or  
JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at  
customer.service@jdsu.com.  
Sample: WRT-740DC240B-057  
WRT-740DC240B-  
Code  
047  
049  
051  
053  
055  
057  
059  
061  
Frequency  
1471 nm  
1491 nm  
1511 nm  
1531 nm  
1551 nm  
1571 nm  
1591 nm  
1611 nm  
Note: For current compatible SFPs, please contact your local JDSU account manager.  
All statements, technical information and recommendations related to the products herein are based upon information believed to be  
reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any  
inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves  
the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, includ-  
ing withdrawal at any time of  
a product offered for sale herein. JDSU makes no representations that the products  
herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU, Waveready, and the  
JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. ©2006 JDS  
Uniphase Corporation. All rights reserved. 30137338 Rev. 001 03/06 WRT740CWDM.DS.CMS.AE  
NORTH AMERICA: 800 498-JDSU (5378)  
WORLDWIDE: +800 5378-JDSU  
WEBSITE: www.jdsu.com  

相关型号:

WRT-740DC240B-051

Long Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, CWDM,3R Transponder
JDSU

WRT-740DC240B-053

Long Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, CWDM,3R Transponder
JDSU

WRT-740DC240B-055

Long Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, CWDM,3R Transponder
JDSU

WRT-740DC240B-057

Long Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, CWDM,3R Transponder
JDSU

WRT-740DC240B-059

Long Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, CWDM,3R Transponder
JDSU

WRT-740DC240B-061

Long Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, CWDM,3R Transponder
JDSU

WRT-740DT240B-135

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-137

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-144

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-145

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-146

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU

WRT-740DT240B-147

Extended Reach, Client-Side SFP, Multi-Rate,Multi-Protocol, DWDM,3R Transponder
JDSU