LA50-S/SP1 [LEM]

Current Transducer LA 50-S/SP1; 电流传感器LA 50 -S / SP1
LA50-S/SP1
型号: LA50-S/SP1
厂家: LEM    LEM
描述:

Current Transducer LA 50-S/SP1
电流传感器LA 50 -S / SP1

传感器
文件: 总2页 (文件大小:131K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Current Transducer LA 50-S/SP1  
IPN = 50 A  
For the electronic measurement of currents : DC, AC, pulsed...,  
with a galvanic isolation between the primary circuit (high power)  
and the secondary circuit (electronic circuit).  
Electrical data  
IPN  
IP  
RM  
Primary nominal r.m.s. current  
Primary current, measuring range  
Measuring resistance  
50  
A
A
Features  
0 .. ± 100  
RM min RMmax  
· Closed loop (compensated) current  
transducer using the Hall effect  
· Insulated plastic case recognized  
according to UL 94-V0.  
with ± 15 V  
@ ± 50 Amax  
@ ± 100 Amax  
0
0
330  
100  
W
W
ISN  
KN  
VC  
IC  
Secondary nominal r.m.s. current  
Conversion ratio  
Supply voltage (± 5 %)  
Current consumption  
R.m.s. voltage for AC isolation test, 50 Hz, 1 min  
25  
mA  
1 : 2000  
± 15  
10 + IS  
3
Special features  
V
mA  
kV  
· IP  
= 0 .. ± 100 A  
Vd  
· KN = 1 : 2000  
Advantages  
Accuracy - Dynamic performance data  
· Excellent accuracy  
· Very good linearity  
XG  
Overall accuracy @ IPN, TA = 25°C  
Linearity  
± 0.5  
< 0.1  
%
%
e
L
· Low temperature drift  
· Optimized response time  
· Wide frequency bandwidth  
· No insertion losses  
· High immunity to external  
interference  
Typ Max  
IO  
IOT  
Offset current @ IP = 0, TA = 25°C  
Thermal drift of IO  
± 0.1 mA  
- 10°C .. + 70°C  
± 0.2 ± 0.4 mA  
tr  
Response time 1) @ 90 % of IPN  
< 1  
> 50  
DC .. 150  
µs  
A/µs  
kHz  
di/dt di/dt accurately followed  
f
Frequency bandwidth (- 1 dB)  
· Current overload capability.  
Applications  
General data  
· AC variable speed drives and servo  
motor drives  
· Static converters for DC motor drives  
· Battery supplied applications  
· Uninterruptible Power Supplies  
(UPS)  
TA  
TS  
RS  
m
Ambient operating temperature  
Ambient storage temperature  
Secondary coil resistance @ TA = 70°C  
- 10 .. + 70  
- 25 .. + 85  
130  
45  
EN 50178  
°C  
°C  
W
g
Mass  
Standards  
2)  
· Switched Mode Power Supplies  
(SMPS)  
· Power supplies for welding  
applications.  
1)  
Notes : With a di/dt of 50 A/µs  
2)  
A list of corresponding tests is available.  
991014/5  
LEM Components  
www.lem.com  
Dimensions LA 50-S/SP1 (in mm. 1 mm = 0.0394 inch)  
Front view  
Left view  
Secondary terminals  
Terminal + : supply voltage + 15 V  
Terminal - : supply voltage - 15 V  
Terminal M : measure  
Terminal 0 : NC  
Connection  
Top view  
Mechanical characteristics  
Remarks  
· General tolerance  
· Fastening  
· Primary through-hole  
· Connection of secondary  
± 0.2 mm  
· IS is positive when IP flows in the direction of the arrow.  
· Temperature of the primary conductor should not exceed  
100°C.  
· Dynamic performances (di/dt and response time) are best  
with a single bar completely filling the primary hole.  
· In order to achieve the best magnetic coupling, the primary  
windings have to be wound over the top edge of the device.  
· To measure nominal currents of less than 50 A, the optimum  
accuracy is obtained by having several primary turns (nomi-  
nal current x number of turns < 50 At).  
2 holes Æ 3.2 mm  
12.7 x 6.35 mm  
Molex 5045-04/AG  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.  

相关型号:

LA50-SP1

Current Transducer
LEM

LA50-S_06

Current Transducer
LEM

LA5000

2 to 5V 60mA Low Saturation Voltage Regulators
SANYO

LA5000M

2 TO 10V 60MA LOW SATURATION VOLTAGE REGULATORS
SANYO

LA5002

2 to 5V 60mA Low Saturation Voltage Regulators
SANYO

LA5002M

2 TO 10V 60MA LOW SATURATION VOLTAGE REGULATORS
SANYO

LA5003

2 to 5V 60mA Low Saturation Voltage Regulators
SANYO

LA5003M

2 TO 10V 60MA LOW SATURATION VOLTAGE REGULATORS
SANYO

LA5004

2 to 5V 60mA Low Saturation Voltage Regulators
SANYO

LA5004M

2 TO 10V 60MA LOW SATURATION VOLTAGE REGULATORS
SANYO