Power Supply  
HVO Series  
FEATURES:  
AC Input 100~277VAC  
Built-in Active PFC Function  
Protection: SCP / OVP / OTP  
12V Auxiliary Output  
Built-in 3 in 1 dimming function (0-10Vdc, 10V PWM signal, or resistance)  
Power saving < 0.35W at Dim to off.  
● Flicker Free  
High Operating Ambient Temp.: -40~+60℃  
Surge protection: L-N 4KV, L-FG/N-FG 6KV  
Safety: UL 8750  
EMI: FCC Part 15 Class B / CE  
IP 67 Compliant  
Warranty: 3 years (refer to warranty policy)  
RoHS Compliant  
PRODUCT SPECIFICATION  
DC OUTPUT DC OUTPUT  
OUTPUT  
CURRENT  
(A)  
OUTPUT  
CURRENT  
TOLERANCE  
Power Factor (Typ.)  
EFFICIENCY (Ref.)  
MODEL  
POWER  
(W)  
VOLTAGE  
(V)  
100VAC 120VAC 200VAC 277VAC 100VAC 120VAC 200VAC 277VAC  
HVO100U351FFB0  
HVO100U701FFB0  
HVO100U112FFB0  
HVO100U142FFB0  
HVO120U701FFB0  
HVO120U112FFB0  
HVO120U142FFB0  
HVO120U182FFB0  
HVO150U701FFB0  
HVO150U112FFB0  
HVO150U142FFB0  
HVO150U182FFB0  
HVO150U212FFB0  
100  
100  
100  
100  
120  
120  
120  
120  
150  
150  
150  
150  
150  
143 - 286  
72 - 143  
48 - 95  
0.35  
0.7  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
±5%  
86.0% 88.0% 90.0% 90.0% 0.98  
86.0% 88.0% 90.0% 90.0% 0.98  
85.0% 87.0% 90.0% 90.0% 0.98  
85.0% 87.0% 90.0% 90.0% 0.98  
85.0% 87.0% 90.0% 91.0% 0.98  
85.0% 87.0% 90.0% 91.0% 0.98  
84.0% 86.0% 89.0% 90.0% 0.98  
84.0% 86.0% 89.0% 90.0% 0.98  
86.0% 88.0% 91.0% 92.0% 0.98  
86.0% 88.0% 91.0% 92.0% 0.98  
85.0% 87.0% 90.0% 91.0% 0.98  
85.0% 87.0% 90.0% 91.0% 0.98  
85.0% 87.0% 90.0% 91.0% 0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.98  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
1.05  
1.4  
36 - 72  
107 - 172  
58 - 115  
43 - 86  
0.7  
1.05  
1.4  
34 - 69  
1.75  
0.7  
107 - 214  
71 - 143  
54 - 107  
43 - 86  
1.05  
1.4  
1.75  
2.1  
36 - 72  
Input Specifications  
Min.  
90  
Typ.  
Max.  
305  
63  
Conditions/Description  
Units  
Vac  
Hz  
Input Voltage Range  
Input Frequency Range  
Input Current (100-HVO)  
Input Current (120-HVO)  
Input Current (150-HVO)  
Inrush Current  
47  
1.22  
1.41  
1.76  
100VAC in  
100VAC in  
A
A
100VAC in  
A
65  
A
230VAC in,25Cold start  
277VAC in  
Leakage Current  
0.75  
mA  
Power Factor (PF)  
0.9  
100-277VAC,100% load  
Total Harmonics Distortion (THD)  
Output Specifications  
20  
%
Min.  
Typ.  
Max.  
±3  
Conditions/Description  
Units  
%
Line Regulation  
Load Regulation  
±3  
%
Output Current Regulation  
Ripple and Noise (pk-pk)  
±5  
%
1
20MHz Bandwidth.  
V
*Measured at electronic load LED mode and nominal input voltage  
with DC10V dimming.  
Ripple Current  
<30% of rated output current  
Turn-on Delay Time  
1
*Measured at 100-277VAC and at full load.  
± 10% Tolerance (Available for customization)  
s
V
A
Auxiliary Output Voltage  
Auxiliary Output Source Current  
Protection Functions  
12  
0
0.42  
Min.  
Typ.  
Max.  
Conditions/Description  
Units  
Short Circuit Protection  
Over Voltage Protection  
Over Temp Protection (Tc)  
Auto recovery  
Auto recovery  
Auto recovery  
100  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
Environmental Conditions  
Min.  
-40  
10  
Typ.  
Max.  
60  
Conditions/Description  
Units  
Operating Temperature (Ta)  
Operating Humidity  
Non-condensing  
Non-condensing  
90  
%RH  
Case temperature measured at the case hot spot  
Measured at 277VAC,Ta 60℃  
Operating Case Temperature (Tc)  
86  
Storage Temperature  
Storage Humidity  
Life Time  
-40  
10  
80  
95  
Non-condensing  
Non-condensing  
%RH  
Measured at 277VAC, 45,000 hours at Tc 75°C  
219 * 64.1 * 35.5 mm8.62* 2.52 * 1.40 inch】  
990  
Dimensions(L*W*H)  
Weight  
g
EMC Compliance and Safety  
EMC Compliance  
Comply with EN 55015 (CISPR15)  
Conducted and Radiated Emmission  
Harmonic Current Emissions  
Comply with EN 61000-3-2  
Comply with EN 61000-3-3  
Comply with IEC 61000-4-2  
Voltage Fluctuations & Flicker  
8 KV air discharge, 4 KV contact discharge  
L-N 4KV, L-FG/N-FG 6KV  
Electrostatic Discharge (ESD)  
RF Electromagnetic Field  
Susceptibility  
Comply with IEC 61000-4-3  
Electrical Fast Transient  
Surge Immunity  
Comply with IEC 61000-4-4  
Comply with IEC 61000-4-5  
Comply with IEC 61000-4-6  
EMS Standards  
Conducted RF Disturbances  
Power Frequency Magnetic Field Comply with IEC 61000-4-8  
Voltage Dips Comply with IEC 61000-4-11  
Safety  
Comply with UL 8750  
Comply with PSE  
UL  
PSE  
Notes  
(1) All specifications Typical @25, unless otherwise noted, at normal line and load.  
(2) Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.  
(3) Specified for free-air convection cooling.  
(4) 3 in 1 Dimming function .(Analog voltage 0~10VDC ; 10V PWM signal 500Hz ~ 10 KHz ; Resistor 1K~100K)  
(4) Minimum load is NOT required for proper operation .  
REFERENCE: www.linkcom.com.tw  
Please contact sales@linkcom.com.tw, sales@linkcomusa.com for more information  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
DERATING CURVE (HVO-100W)  
DERATING CURVE (HVO-120W)  
DERATING CURVE (HVO-150W)  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
DIMENSIONS  
REFERENCE: www.linkcom.com.tw  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
DIMMING OPERATION  
DC 0-10V Dimmiable  
Parameters  
Minimum  
0V  
0mA  
Typical  
Maximum  
10V  
1mA  
Absolute maximum voltageon on the 0-10(+) Purple Wire  
Source current on the 0-10V(+) Purple Wire  
RED (LED+)  
BLACK (LED-)  
BROWN (AUX+)  
PURPLE (DIM+)  
HVO Series  
SENSOR  
Dimmer  
GRAY (AUX-/DIM-)  
Compatible Occupancy Sensors  
Manufacturer  
Sensor Model number  
IR-TEC  
Acuity Brands Lighting  
BOA 5xx Series  
Sensor Switch MSOD 7  
12~24VDC  
12~24VDC  
DC 0-10V Dimming Performance  
Notes:  
1. Purple and Gray wires on the output side are used for 0-10V dimming.  
2. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent.  
3. When dimming wires +Purple/-Gray are left open, the output current will be at 100%.  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
PWM Dimmiable  
Parameters  
Minimum  
Typical  
0V  
10V  
Maximum  
Input LOW Level Voltage Range (Purple Wire)  
Input HIGH Level Voltage Range (Purple Wire)  
Current into PWM Input (Purple Wire)  
PWM Input Signal Frequency  
10KHz  
0.1mA  
500Hz  
PWM Dimmiable Duty cycle 0%~100% 10V 1KHz Dimming Performance  
Dimmiable External Resistor  
Parameters  
Resistance range of Dimmable  
Resistance of Dim to off  
Minimum  
Typical  
Maximum  
100K  
10K  
5K  
Dimmiable External Resistor Dimming Performance  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
Output Current vs. Load (HVO150U142FFB0)  
Output Current vs. Load  
1.500  
1.400  
1.300  
1.200  
1.100  
1.000  
Vin=100  
Vin=120  
Vin=200  
Vin=230  
Vin=277  
40%  
50%  
60%  
70%  
80%  
90%  
100%  
110%  
Load (%)  
Efficiency vs. Load (HVO150U142FFB0)  
Efficiency vs. Load  
100.0%  
90.0%  
80.0%  
70.0%  
60.0%  
Vin=100  
Vin=120  
Vin=200  
Vin=230  
Vin=277  
40%  
50%  
60%  
70%  
80%  
90%  
100%  
110%  
Load (%)  
THD vs. Load (HVO150U142FFB0)  
THD vs. Load  
50.0%  
40.0%  
30.0%  
20.0%  
10.0%  
0.0%  
Vin=100  
Vin=120  
Vin=200  
Vin=230  
Vin=277  
40%  
50%  
60%  
70%  
80%  
90%  
100%  
110%  
Load (%)  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
PF vs. Load (HVO150U142FFB0)  
PF vs. Load  
1.00  
0.95  
0.90  
0.85  
0.80  
0.75  
0.70  
Vin=100  
Vin=120  
Vin=200  
Vin=230  
Vin=277  
40%  
50%  
60%  
70%  
80%  
90%  
100%  
110%  
Load (%)  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  
Power Supply  
HVO Series  
Linkcom Manufacturing Co., Ltd.  
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY