FLU011 [LITTELFUSE]

Supplementary Overcurrent Protection; 补充过流保护
FLU011
型号: FLU011
厂家: LITTELFUSE    LITTELFUSE
描述:

Supplementary Overcurrent Protection
补充过流保护

文件: 总4页 (文件大小:239K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Midget Fuses  
Supplementary Overcurrent Protection  
Ampere Ratings:  
KLK Fuses  
FAST-ACTING 600 VAC  
1
8
10  
1
4
5
6
7
8
9
10  
12  
15  
20  
25  
30  
1
11⁄  
2
2
2
Fast-acting, high-interrupting capacity,  
current-limiting type fuse. Especially suited  
for control circuits, street lighting, H.I.D.  
lighting, computers, and other applications  
without high inrush currents.  
10  
1
4
21⁄  
3
2
3
10  
1
2
31⁄  
2
3
4  
Approvals: Standard 248-14  
UL Listed 3/10-30A  
Voltage Rating: 600 Volts AC  
500 Volts DC  
(File No: E10480)  
CSA Certified 3/10-30A  
(File No: LR29862)  
Versions available to meet  
MIL-F-5160/60, QPL F60C:  
Contact Factory.  
Interrupting Rating: UL Listed 100,000  
amperes rms symmetrical  
(Capable of 200,000 amperes)  
Dimensions: 13/32" x 1-1/2"  
Example part number (series & amperage): KLK 1-1/2  
Ampere Ratings:  
KLKD Fuses  
FAST-ACTING 600 VAC/DC  
1
8  
10  
1
4
5
6
7
8
9
10  
12  
15  
20  
25  
30  
1
11⁄  
2
2
2
4
10  
Fast-acting, high-interrupting capacity,  
1
21⁄  
3
2
current-limiting type fuse. Especially suited  
for DC control circuits, street lighting, H.I.D.  
lighting, computers, and other applications.  
3
10  
1
2
31⁄  
2
3
4
Voltage Rating: 600 Volts AC/DC  
Approvals: Standard 248-14  
UL Listed 3/10-30A  
Interrupting Rating: AC: 100,000 amperes  
rms symmetrical; DC: 10,000 amperes  
(File No: E10480)  
CSA Certified 3/10-30A  
(File No: LR29862)  
Dimensions: 13/32" x 1-1/2"  
Example part number (series & amperage): KLKD 30  
Ampere Ratings:  
FLM Fuses  
TIME-DELAY 250 VAC  
11⁄  
11⁄  
8
3
7
8
9
10  
12  
15  
20  
25  
30  
1
10  
15  
100  
4
3210  
2
4
10  
1410  
31⁄  
2
Use FLM 250 volt time-delay fuses to  
protect control circuit transformers,  
solenoids, and other circuits with high  
inrush currents. Excellent for supplemental  
protection of small motors. For motor  
branch-circuit protection, See Class  
CC fuses.  
1
11⁄  
2
4
3
4
1
6
8
10  
1610  
1810  
2
41⁄  
5
2
10  
2
5610  
6
10  
21⁄  
4
10  
21⁄  
2
61⁄  
4
1
2810  
Voltage Rating: 250 Volts AC  
Approvals: Standard 248-14  
UL Listed (File No: E10480)  
CSA Certified  
(File No: LR29862)  
Interrupting Rating: AC: 10,000 amperes  
rms symmetrical.  
Dimensions: 13/32" x 1-1/2"  
Example part number (series & amperage): FLM 15  
Ampere Ratings:  
FLQ Fuses  
TIME-DELAY 500 VAC  
3210  
8
9
1
8
10  
10  
1
8
1
31⁄  
2
15  
100  
11⁄  
8
4
10  
12  
14  
15  
20  
25  
30  
These 500 volt time-delay fuses provide  
excellent supplemental protection of control  
power transformers, solenoids, and circuits  
with high inrush currents. UL and CSA 500  
volt ratings permit use on 480 volt circuits.  
FLQ fuses also provide supplemental  
protection to small motors. For motor  
branch-circuit protection, see Class  
CC fuses.  
3
10  
16  
11⁄  
4
41⁄  
5
2
2
11⁄  
1610  
2
2
1
3
4
1
6
4
5610  
6
10  
10  
21⁄  
4
61⁄  
4
2
21⁄  
2
7
10  
3
Approvals: Standard 248-14  
UL Listed (File No: E10480)  
CSA Certified  
Voltage Rating: 500 Volts AC  
(File No: LR29862)  
Dimensions: 13/32" x 1-1/2"  
Example part number (series & amperage): FLQ 1/2  
Interrupting Rating: 10,000 amperes  
rms symmetrical  
RECOMMENDED FUSE BLOCKS  
L60030M series. Refer to Fuse Block section of this catalog for additional information.  
49  
Midget Fuses  
Supplementary Overcurrent Protection  
Ampere Ratings:  
BLN Fuses  
FAST-ACTING 250 VAC  
1
2
3
4
5
6
8
10  
12  
15  
20  
25  
30  
Fiber tube, 250 volt BLN fuses provide low-  
cost protection for military applications and  
control circuits.  
Approvals: Standard 248-14  
UL Listed (File No: E10480)  
CSA Certified  
(File No: LR29862)  
Versions available to meet  
MIL-F-15160/9, QPL F09A:  
Contact Factory  
Voltage Rating: 250 Volts AC  
Interrupting Rating: 10,000 amperes rms  
symmetrical  
Dimensions: 13/32" x 1-1/2"  
Example part number (series & amperage): BLN 30  
Ampere Ratings:  
BLF Fuses  
FAST-ACTING 125/250 VAC  
1
2
3
4
5
6
7
8
9
10  
12  
15  
20  
25  
30  
1
11⁄  
2
2
Laminated tube BLF fuses are the lowest  
price midget fuse. They are suitable for  
control circuit and instrument protection in  
dry locations.  
21⁄  
2
61⁄  
4
Approvals: Standard 248-14  
Voltage Ratings: 250 Volts AC: 1/2 – 15  
amperes; 125 Volts AC: 20 – 30 amperes  
UL Listed (File No: E10480)  
CSA Certified  
(File No: LR29862)  
Dimensions: 13/32" x 1-1/2"  
Example part number (series & amperage): BLF 5  
Interrupting Rating: 10,000 amperes rms  
symmetrical  
Ampere Ratings:  
BLS Fuses  
FAST-ACTING 250/600 VAC  
2
10  
10  
1
2
3
4
5
6
7
8
10  
4
11⁄  
2
1
1610  
1810  
BLS fuses are 1-3/8" long in contrast to  
other midget fuses which are 1-1/2". They  
provide space-saving, low-cost, protection  
to street lighting, metering, control and  
electronic circuits.  
2
3
4
8
10  
Approvals: Standard 248-14  
UL Listed 1/2-5 Amps  
(File No: E10480)  
CSA Certified 1/2 – 5 Amps  
(File No: LR29862)  
Voltage Rating: 600 Volts AC: 2/10 – 5  
amperes; 250 Volts AC: 6 – 10 amperes  
Interrupting Rating: 10,000 amperes  
rms symmetrical  
Dimensions: 13/32" x 1-3/8"  
Example part number (series & amperage): BLS 10  
Ampere Ratings:  
FLA Fuses  
TIME-DELAY 125 VAC  
10  
11⁄  
11⁄  
8
2810  
3
61⁄  
7
8
10  
12  
15  
20  
25  
30  
4
1
15  
100  
4
2
10  
1410  
3210  
FLA fuses are 125 volt, pin-indicating time-  
delay fuses for protection of control circuit  
transformers, solenoids, and other circuits  
with high inrush currents. Metal indicating pin  
“pops-out” when fuse opens. Pin gives visual  
indication of open fuse. Use FLA fuses in  
conjunction with special fuseblocks to operate  
mechanical signal switches or energize alarm  
circuits. Fuses rated 12 amperes and above  
have dual-tube construction.  
1
4
11⁄  
2
31⁄  
2
3
4
1
6
8
10  
1610  
1810  
2
4
*
*
*
*
*
10  
41⁄  
5
2
2
10  
21⁄  
4
5610  
6
10  
21⁄  
2
1
Approvals: Standard 248-14  
UL Listed (File No: E10480)  
CSA Certification Pending  
Voltage Rating: 125 Volts AC  
Dimensions: 13/32" x 1-1/2"  
Note: Dual tube construction  
Interrupting Rating: 10,000 amperes rms  
symmetrical  
*
Example part number (series & amperage): FLA 15  
RECOMMENDED FUSE BLOCKS  
L60030M series. Refer to Fuse Block section of this catalog for additional information.  
50  
Midget Fuses  
Supplementary Overcurrent Protection  
SPECIFICATIONS  
Voltage Rating: 600VAC  
NEW  
Interrupting Rating: 10,000 amperes  
Ampere Range: 1 – 6 amperes  
Approvals: Standard 248-14 UL Listed (File No: E10480)  
Dimensions: 13/32" x 1-3/8"  
AMPERE RATINGS  
1
2
3
4
5
6
1-6/10  
RECOMMENDED FUSE BLOCKS  
L60030M Series. Refer to Fuse Block section of this catalog  
for additional information.  
ORDERING INFORMATION  
Example catalog number: KLQ005  
Example system number: 0KLQ005.T  
CROSS REFERENCE  
Littelfuse  
Buss  
Ferraz-Shawmut  
KLQ Series Fuses  
KLQ  
KTQ  
The Littelfuse KLQ series is designed to protect gaseous  
vapor fixtures, HID ballasts, and other electronic and lighting  
circuits. The KLQ is the same physical size as the Littelfuse  
BLS, but has more time delay to handle transient and inrush  
currents.  
SPECIFICATIONS  
Voltage Rating: 1000 VAC/VDC  
Interrupting Rating: 44/100A: 10kA  
NEW  
11A: 20kA  
Ampere Range: 44/100 and 11 amperes  
Approvals: UL Recognized under the components program.  
(File No: E10480)  
CSA Certified (File No: LR29862)  
Dimensions: 44/100A: 13/32" x 1-3/8"  
11A: 13/32" x 1-1/2"  
ORDERING INFORMATION  
Example catalog number: FLU011  
Example system number: 0FLU011.T  
CROSS REFERENCE  
Littelfuse  
Buss  
Ferraz-Shawmut  
FLU  
DMM  
FLU Series Fuses  
The Littelfuse FLU series is designed specifically for the  
protection of multimeters. The 1000 VAC/VDC rating also  
makes the FLU ideal for a variety of other applications.  
51  
Midget Fuses  
Supplementary Overcurrent Protection  
KLK  
KLKD  
1000  
800  
600  
1000  
800  
600  
400  
300  
400  
300  
200  
200  
100  
80  
60  
100  
80  
60  
40  
30  
40  
30  
20  
20  
10  
8
6
10  
8
6
4
3
4
3
2
2
1
1
.8  
.8  
.6  
.6  
.4  
.3  
.4  
.3  
.2  
.2  
.1  
.1  
.08  
.08  
.06  
.06  
.04  
.03  
.04  
.03  
.02  
.02  
.01  
.01  
CURRENT IN AMPERES  
CURRENT IN AMPERES  
FLM  
FLQ  
1000  
800  
600  
1000  
800  
600  
400  
300  
400  
300  
200  
200  
100  
80  
60  
100  
80  
60  
40  
30  
40  
30  
20  
20  
10  
8
6
10  
8
6
4
3
4
3
2
2
1
1
.8  
.8  
.6  
.6  
.4  
.3  
.4  
.3  
.2  
.2  
.1  
.1  
.08  
.08  
.06  
.06  
.04  
.03  
.04  
.03  
.02  
.02  
.01  
.01  
CURRENT IN AMPERES  
CURRENT IN AMPERES  
52  

相关型号:

FLU011.

Axial Lead and Cartridge Fuses - Midget
LITTELFUSE

FLU011.U

Electric Fuse, 11A, 1000VAC, 1000VDC, 20000A (IR), Inline/holder
LITTELFUSE

FLU1-40

40W SINGLE OUTPUT SWITCHING POWER SUPPLIES
SLPOWER

FLU1-40-1AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-40-2AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-40-3AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-40-4AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-40-5AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-40-6AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-50-1AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-50-2AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER

FLU1-50-3AD

OPEN-FRAME SWITCHING POWER SUPPLIES
SLPOWER