1-6609113-3 [MACOM]
Switch with IEC Connector Compact Size; 开关符合IEC连接器体积小巧型号: | 1-6609113-3 |
厂家: | Tyco Electronics |
描述: | Switch with IEC Connector Compact Size |
文件: | 总2页 (文件大小:89K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CORCOM Product Guide
Switch with IEC Connector Compact Size
C Series
UL Recognized
CSA Certified
VDE Approved
CFS
CS
†Applies to Filtered models only.
C Series
Specifications
Maximum leakage current, each line to ground: †
F Models
Two function power entry module combining a DPST switch
and an IEC 320 power line connector. Compact packaging
allows a smaller panel cutout with choice of snap-in or
flange mounting. Available with general purpose filtering (F
models - CFS, CFE), medical application filtering (H models
- CHS, CHE) or unfiltered (CS, CE). Terminals allow for easy
connection to any wiring scheme. Preconnected terminals
from line to switch are available (B Models - CBS, CBE) for
reducing OEM wiring time.
H Models
@120 VAC 60 Hz:
@250 VAC 50 Hz:
Hipot rating (one minute):
line-to-ground
.25 mA
.40 mA
2 µA
5 µA
2250 VDC
1450 VDC
50/60 Hz
line-to-line
Operating frequency:
Rated voltage:
Operating voltages:
Switch:
250 VAC
The medical versions (H models) are designed specifically
for health care applications. Their extremely low leakage
current allows compliance with UL544 and UL2601 as well
as CSA22.2 health care specifications for use with both
patient and non-patient care equipment. For more
115/230 VAC
Double-insulated rated
for 10,000 operations
at full load.
51 Amp inrush capability.
information on UL544 or UL2601, see Appendix C.
Unfiltered Push-on Force:
18 lb/80 N
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency MHz
Rating
F Models
0 1A
0 3A
0 6A
0.05 0.15 0.5
1
5
10
30
Electrical Schematics
10
8
26
16
11
4
46
32
22
14
48
36
27
18
46
43
36
27
47
48
41
33
46
50
50
42
F Models (CFS, CFE)
4
LINE
LOAD
10A
1
H Models
0 1A
0 3A
0 6A
10A
16
9
4
21
14
10
6
37
31
22
10
44
32
23
15
26
26
19
11
21
24
18
11
10
14
13
9
H Models (CHS, CHE)
2
LINE
LOAD
Line-to-line in 50 ohm circuit
Current
Rating
F Models
0 1A
0 3A
0 6A
10A
H Models
0 1A
0 3A
0 6A
Frequency MHz
0.05 0.15 0.5
1
5
10
30
B Models (CBS, CBE)
1
2
2
1
3
6
6
7
13
14
14
14
28
23
27
23
62
65
46
42
67
65
48
44
42
67
58
62
Power On/Off
L
L
G
N
Note 1
Note 1
Note 2
Note 2
G
N
1
6
5
5
4
13
10
14
11
29
22
20
19
38
36
31
32
42
34
33
37
26
36
37
38
1
1
1
Note 1: Jumpers provided on CBS and CBE versions only.
Note 2: Location of optional filter
10A
Resistor location for reference only.
110
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany: 49-89-6089-0
www.corcom.com
www.tycoelectronics.com
reference purposes only.
Specifications subject
to change.
CORCOM Product Guide
Switch with IEC Connector Compact Size (Continued)
C Series
CBS, CBE Pre-Connected Terminals
Case Styles
*
CE, CBE
C
1.04
26.4
Max
.211
5.36
Max.
CBS, CBE Side View
CBS Rear View
CBE Rear View
B
F
A
*
CS, CBS
Case Dimensions
A
B
C
D
E
F
± .006
± .152
± .006
± .006
± .152
Part No. (max) (max) (max)
± .152
C
1.23
.97
1.62
1.06
1.54
CS, CBS
CE, CBE
CFS, CHS
CFE, CHE
—
31.24 24.64 41.17 26.92 39.12
1.74
44.2
1.23
.97
24.64 41.17 26.92 39.12
2.53 1.62 1.12 1.54
28.5 39.12
1.12 1.54
28.5 39.12
1.62
1.06
1.54
1.417
36.0
.211
5.36
Max.
B
A
—
31.24 64.26 41.17
1.74
44.2
2.53
1.62
1.417
36.0
CFE, CHE
64.26 41.17
C
Part Numbers
01CFS1
03CFS1
06CFS1
10CFS1
10CS1
01CFE1
01CHS1
01CHE1
.211
5.36
Max.
03CFE1
06CFE1
10CFE1
10CE1
03CHS1
06CHS1
10CHS1
10CBS1
03CHE1
06CHE1
10CHE1
10CBE1
B
F
A
CFS, CHS
Recommended Panel Cutout
C
Panel Cutout for thickness of .031-
.098 [.8-2.5]. Not recommended for
plastic panels. For snap-in applica-
tions, the D sides of the cutout must
have a .02 [.508] radius on the instal-
lation side. Snap-in models allow
front mounting only.
.06
1.52
D
R max
.211
5.36
Max.
B
E
A
Typical Dimensions:
F
Mounting Holes: .13 [3.3] Dia. (2) with .23 Dia. x 90˚ Counter sunk
Terminals: .250 [6.35] (3)
Holes: .07 [1.8] Dia.
111
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
www.corcom.com
www.tycoelectronics.com
Germany:
49-89-6089-0
相关型号:
1-6610005-5
Telecom and Datacom Connector, 16 Contact(s), Female, Right Angle, Solder Terminal, Jack
BEL
©2020 ICPDF网 联系我们和版权申明