2-1393767-8 [MACOM]

R10 Series Panel Plug-in Relay; R10系列面板插入式继电器
2-1393767-8
型号: 2-1393767-8
厂家: Tyco Electronics    Tyco Electronics
描述:

R10 Series Panel Plug-in Relay
R10系列面板插入式继电器

继电器
文件: 总6页 (文件大小:1024K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay  
n
n
1 through 8 form C (CO) contact arrangement  
Broad range of coil options provides sensitivity ranging from 25 to  
750mW  
n
n
Various contacts switch from dry circuit to 7.5 amps  
Many mounting and termination options  
Typical applications  
Coin changers, audio equipment, elevators, traffic controls, ultrasonic test  
equipment, parking toll readers  
R10  
R10-R  
R10S  
R10-T  
Approvals  
UL E29244; CSA LR15734  
Technical data of approved types on request  
Contact ratings (continued)  
Type  
Load  
Cycles  
UL 508  
P type, Au overlay Ag, bifurcated crossbar contact  
2A, 120VAC, resistive  
Contact Data  
100x103  
6x103  
Contact arrangement  
1, 2, 3, 4, 6 and 8 Form C (CO)  
120VAC  
3 A, 120 VAC, resistive  
3 A, 30 VDC, resistive  
Rated voltage  
100x103  
Rated current  
Contact material  
Contact style  
7.5A  
L type, AuPtAg, bifurcated crossbar contact  
500mA, 28VDC, resistive  
Mechanical endurance  
Ag, AgCdO, Au overlay Ag, AuPtAg  
Single or bifurcated crossbar  
6x103  
10x106 ops., except W type is 1x106 ops.  
Min. recommended contact load  
W type, AgCdO, single contact  
X type, AgCdO, single contact  
M type, AgCdO, bifurcated contact  
Y type, Ag, single contact  
Z type, Ag, bifurcated crossbar  
P type, Au overlay Ag, bifurcated crossbar  
L type, AuPtAg, bifurcated crossbar  
Initial contact resistance  
300mA, 12VDC  
300mA, 12VDC  
300mA, 12VDC  
100mA, 12VDC  
1mA, 12VDC  
Coil Data  
Coil voltage range  
3 to 115VDC  
4.5mA to 20mA  
6 to 115VAC  
dry circuit  
dry circuit  
Coil versions, DC coil  
Coil  
code  
Rated  
voltage  
VDC  
Operate  
voltage  
VDC  
Coil  
resistance  
Ω 10ꢀ  
Rated coil  
power  
mW  
All AgCdO contact types  
All other contact materials and types  
Frequency of operation  
100mΩ  
50mΩ  
360 ops./hr  
V - standard DC voltage adjustment  
1, 2 and 4 pole  
V10  
V28  
V52  
V185  
V700  
V2.5K  
V5.8K  
V15.0K  
6 pole  
V6  
V16  
V25  
V90  
V430  
V1.5K  
V3.5K  
V9.0K  
8 pole  
V5  
3
5
6
12  
24  
48  
72  
115  
2.25  
3.75  
4.5  
9
10  
28  
52  
185  
700  
2500  
5800  
15000  
900  
900  
900  
900  
900  
900  
900  
900  
Contact ratings  
Type  
Load  
Cycles  
UL 508  
W type, AgCdO, single contact  
7.5A, 120VAC, resistive  
18  
36  
54  
86  
7.5A, 28VDC, resistive  
1/8HP, 120VAC, same polarity  
1/6HP, 240VAC, same polarity  
X type, AgCdO, single contact  
3
5
6
12  
24  
48  
72  
115  
2.25  
6
16  
25  
90  
430  
1500  
3500  
9000  
1,500  
1,600  
1,500  
1,600  
1,400  
1,600  
1,500  
1,500  
2A, 30VDC, resistive  
5A, 120VAC, resistive  
5A, 30VDC, resistive  
1/20HP, 120VAC, same polarity  
1/10HP, 240VAC, same polarity  
100x103  
6x103  
3.75  
4.5  
9
100x103  
18  
36  
54  
86  
M type, AgCdO, bifurcated contact  
5A, 120VAC, resistive  
5A, 28VDC, resistive  
Y type, Ag, single contact  
6x103  
6x103  
3
5
6
12  
24  
48  
72  
115  
2.25  
5
14  
20  
72  
350  
1250  
2800  
8000  
1,800  
1,800  
1,800  
2,000  
1,700  
1,900  
1,900  
1,700  
2A, 120VAC  
2A, 28VDC  
250VA, 250VAC  
6x103  
6x103  
V14  
V20  
V72  
V350  
V1.25K  
V2.8K  
V8.0K  
3.75  
4.5  
9
30x103  
100x103  
125VA, 125VAC  
18  
Z type, Ag, bifurcated crossbar contact  
3A, 120VAC  
36  
54  
86  
6x103  
6x103  
3A, 28VDC  
2A, 30VDC  
100x103  
All figures are given for coil without preenergization, at ambient temperature +23°C.  
1
08-2011, Rev. 0811  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay (Continued)  
Coil  
resistance  
Ω 10ꢀ  
Rated coil  
power  
mW  
Coil  
resistance  
Ω 10ꢀ  
Rated coil  
power  
mW  
Q - special DC voltage adjustment  
1 and 2 pole  
S - sensitive DC voltage adjustment (continued)  
2 pole  
Q52  
Q110  
5
6
3.1  
4.5  
52  
110  
450  
1,800  
7500  
15000  
30000  
500  
350  
350  
350  
310  
350  
450  
SS110  
SS350  
SS500  
SS2.0K  
SS4.5K  
SS7.5K  
SS15.0K  
SS30.0K  
3 and 4 pole  
SS52  
3
5
6
12  
18  
24  
36  
48  
2.25  
3.75  
4.5  
9
110  
350  
500  
2000  
4500  
7500  
15000  
30000  
85  
75  
75  
75  
75  
80  
85  
80  
Q450  
12  
24  
48  
72  
115  
9.2  
Q1.8K  
Q7.5K  
Q15.0K  
Q30.0K  
3 and 4 pole  
Q32  
17.4  
36.2  
49.5  
67.5  
13.5  
18  
27  
36  
5
6
3.8  
4.2  
32  
52  
185  
1000  
3200  
7500  
15000  
800  
700  
800  
600  
750  
700  
900  
Q52  
3
2.25  
52  
175  
250  
1000  
2200  
3700  
7500  
15000  
175  
150  
150  
150  
150  
150  
175  
150  
Q185  
12  
24  
48  
72  
115  
8.4  
SS175  
SS250  
SS1.0K  
SS2.2K  
SS3.7K  
SS7.5K  
SS15.0K  
5
6
12  
18  
24  
36  
48  
3.75  
4.5  
9
Q1.0K  
Q3.2K  
Q7.5K  
Q15.0K  
17.2  
31.1  
49.3  
67.5  
13.5  
18  
27  
36  
S - sensitive DC voltage adjustment  
1 and 2 pole  
S50  
S140  
S200  
S800  
S3.2K  
S13.0K  
S28.0K  
S50.0K  
3 and 4 pole  
S30  
S80  
S110  
S450  
S1.8K  
S7.5K  
S16.0K  
S40.0K  
6 pole  
S20  
S56  
S80  
S320  
S1.2K  
S5.2K  
S13.0K  
S30.0K  
8 pole  
S12  
S35  
S52  
S200  
S800  
S3.2K  
S7.5K  
S16.0K  
3
5
6
12  
24  
48  
72  
115  
2.25  
3.75  
4.5  
9
50  
140  
200  
800  
3200  
13000  
28000  
50000  
180  
180  
180  
180  
180  
180  
190  
270  
Coil  
code  
Maximum  
coil current  
mADC  
Operate  
current  
mADC  
Coil  
resistance  
Ω 10ꢀ  
Pick-up  
coil power  
mW  
18  
J - sensitive DC current adjustment  
2 pole  
J1.0K  
J2.5K  
36  
54  
86  
45  
28  
20  
14  
11.5  
8.3  
8.5  
5.8  
4.1  
3.1  
2.6  
1.7  
1000  
2500  
5000  
10000  
15000  
30000  
75  
85  
85  
100  
100  
85  
J5.0K  
3
5
6
12  
24  
48  
72  
115  
2.25  
30  
80  
110  
300  
350  
350  
350  
350  
300  
350  
350  
J10.0K  
J15.0K  
J30.0K  
4 pole  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J15.0K  
J30.0K  
6 pole  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J15.0K  
J30.0K  
8 pole  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J15.0K  
J30.0K  
3.75  
4.5  
9
450  
18  
1800  
7500  
16000  
40000  
45  
28  
20  
14  
11.5  
8.3  
13  
1000  
2500  
5000  
10000  
15000  
30000  
175  
175  
200  
200  
200  
200  
36  
54  
86  
8.4  
6.2  
4.5  
3.5  
2.5  
3
5
6
12  
24  
48  
72  
115  
2.25  
20  
56  
80  
500  
500  
500  
500  
500  
500  
400  
500  
3.75  
4.5  
9
45  
28  
20  
14  
11.5  
8.3  
16  
10  
7.2  
5
4.2  
2.9  
1000  
2500  
5000  
10000  
15000  
30000  
250  
250  
250  
250  
270  
250  
320  
18  
1200  
5200  
13000  
30000  
36  
54  
86  
3
5
6
12  
24  
48  
72  
115  
2.25  
12  
35  
52  
200  
800  
3200  
7500  
16000  
750  
750  
700  
750  
750  
750  
700  
850  
45  
28  
20  
14  
11.5  
8.3  
20  
13  
9
6.4  
5.3  
3.7  
1000  
2500  
5000  
10000  
15000  
30000  
250  
250  
250  
250  
270  
250  
3.75  
4.5  
9
18  
36  
54  
86  
J - sensitive DC current adjustment - R10S types only  
1 pole  
J500  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J16.0K  
J30.0K  
1)  
SS - ultra sensitive DC voltage adjustment  
1 pole  
SS220  
4.5  
3.2  
2
1.4  
1
0.8  
0.6  
500  
1000  
2500  
5000  
10000  
16000  
30000  
10  
10  
10  
10  
10  
10  
11  
1)  
3
5
6
12  
18  
24  
36  
2.25  
3.75  
4.5  
9
13.5  
18  
27  
220  
700  
1000  
4000  
9000  
15000  
30000  
45  
40  
40  
40  
40  
40  
45  
2)  
SS700  
SS1.0K  
SS4.0K  
SS9.0K  
SS15.0K  
SS30.0K  
3)  
2
08-2011, Rev. 0811  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay (Continued)  
Coil versions, DC coil (continued)  
Operative Range  
R10 Relays (DC Only) Typical Ranges of Operations @ 25°C  
Coil  
code  
Maximum  
coil current  
mADC  
Operate  
current  
mADC  
Coil  
resistance  
Ω 10ꢀ  
Pick-up  
coil power  
mW  
(Curves for reference only. If specific  
J - sensitive DC current adjustment – R10S types only  
values are required, testing is required.)  
2 pole  
30  
25  
12  
10  
1)  
J500  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J16.0K  
J30.0K  
4 pole  
J500  
J1.0K  
J2.5K  
J5.0K  
J10.0K  
J16.0K  
J30.0K  
6.3  
4.5  
2.9  
2
1.4  
1.2  
0.8  
500  
1000  
2500  
5000  
10000  
16000  
30000  
20  
20  
25  
20  
20  
25  
20  
Typical Operate  
and Release Time  
2)  
(all contact configurations)  
8
6
4
2
20  
15  
10  
5
3)  
Release Time  
(no suppression)  
9
500  
1000  
2500  
5000  
10000  
16000  
30000  
45  
45  
45  
45  
40  
35  
45  
6.5  
4.1  
2.9  
2
1.4  
1.2  
2)  
3)  
Operate Time  
1.0  
1.33 1.5  
2.0  
2.5  
3.0  
Multiple of Max. Pull-in Voltage or Current  
1) Suggested for 5VDC operation  
2) Suggested for 12VDC operation  
3) Suggested for 24VDC operation  
R10 Ultra-Sensitive “SS” and “JJ” Typical Ranges of Operation @ 25°C  
JJ - ultrasensitive DC current adjustment  
1 pole  
(Curves for reference only. If specific  
values are required, testing is required.)  
10  
8
50  
JJ1.0K  
JJ2.5K  
JJ5.0K  
JJ10.0K  
JJ15.0K  
JJ30.0K  
2 pole  
JJ1.0K  
JJ2.5K  
JJ5.0K  
JJ10.0K  
JJ15.0K  
JJ30.0K  
4 pole  
45  
28  
20  
14  
11.5  
8.3  
4.5  
2.9  
2.1  
1.5  
1.2  
0.85  
1000  
2500  
5000  
10000  
15000  
30000  
20  
25  
25  
25  
25  
25  
Typical Operate  
and Release Time  
(all contact configurations)  
40  
30  
6
Release Time  
(no suppression)  
45  
28  
20  
14  
11.5  
8.3  
6.5  
4.1  
2.9  
2
1.7  
1.2  
1000  
2500  
5000  
10000  
15000  
30000  
45  
45  
45  
40  
45  
45  
20  
10  
4
2
Operate Time  
3.0  
4.0  
1.0  
1.5 2.0  
JJ1.0K  
JJ2.5K  
JJ5.0K  
JJ10.0K  
JJ15.0K  
JJ30.0K  
45  
28  
20  
14  
11.5  
8.3  
9
1000  
2500  
5000  
10000  
15000  
30000  
85  
85  
85  
90  
85  
90  
Multiple of Max. Pull-in Voltage or Current  
5.8  
4.1  
3
2.4  
1.7  
Typical Coil Inductance  
500  
All figures are given for coil without preenergization, at ambient temperature +23°C.  
100  
50  
Coil versions, AC coil (dual coil diode rectified construction)  
Coil  
Rated  
voltage  
VAC  
Operate  
voltage  
VAC  
Coil  
resistance  
Ω 20ꢀ  
code  
10  
Armature (open)  
Armature (closed)  
Standard AC  
2 and 4 pole  
6V  
12V  
24V  
48V  
115V  
6 and 8 pole  
6V  
12V  
6
5
9
18  
36  
86  
25  
120  
500  
2000  
9000  
1.0  
0.5  
12  
24  
48  
115  
0.1  
10  
50 100  
500 1K  
Coil Resistance (Ohms)  
5K 10K  
100K  
6
5
9
18  
36  
86  
15  
90  
350  
1400  
7500  
12  
24  
48  
115  
24V  
48V  
115V  
All figures are given for coil without preenergization, at ambient temperature +23°C.  
3
08-2011, Rev. 0811  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay (Continued)  
Insulation Data  
Other Data (continued)  
Initial dielectric strength  
between open contacts  
between contact and coil  
between adjacent contacts  
Initial insulation resistance  
between insulated elements  
Terminal type  
500Vrms  
1000Vrms  
1000Vrms  
Solder/plug-in terminals, PCB-THT,  
8- or 11-PIN octal type plug  
23 to 40g  
Weight  
Packaging/unit  
tray/50 pcs., box/350pcs.  
10GΩ, 500VDC  
Accessories  
For details see datasheet  
Sockets and Accessories, R10 Relays  
Other Data  
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content  
refer to the Product Compliance Support Center at  
Product Code Description  
Many versions of sockets and clips available.  
www.te.com/customersupport/rohssupportcenter  
NOTE: Relays with contact current <50mA are not recommended for use in sockets.  
Ambient temperature  
-55ºC to 75ºC  
Category of environmental protection  
IEC 61810  
RTI - dust protected and RTIII - wash tight  
Dimensions  
1.187 MAX .  
(30.15)  
R10S: 1.50 MAX.  
.735 MAX.  
(18.67)  
CASE R ONLY  
(38.1)  
Recommend tape tab  
be removed after  
immersion cleaning  
and before relay is put  
in service. Peel off to  
permit proper relay  
ventilation.  
CASE E  
ONLY  
2 POLE .950 MAX.  
(24.13, 2 POLE 1R10)  
4 POLE 1.165 MAX.  
(29.59, 4 POLE 1R10)  
6 POLE 1.375 MAX.  
(34.93)  
8 POLE 1.580 MAX.  
(40.13)  
.406  
(10.31)  
.085 MAX.  
(2.16)  
.135  
(3.43)  
.171  
(4.43)  
.354  
(8.99)  
TYPE E6 ONLY  
TYPE E6 ONLY  
.210  
.156  
(3.96)  
.375  
(9.53)  
(5.33)  
3-48THREAD  
NIB .091 DIA. x .020 HIGH  
(2.31) (.51)  
#6-32  
THREAD  
TYPE E1 ONLY  
}
.59 REF.  
(15.0)  
.437  
(11.10)  
STUD ON NARROW  
SIDE ONLY  
Terminal dimensions  
Solder terminal dimensions  
.090  
Printed circuit terminal dimensions  
A
B
C
D
Arrang.  
Inline  
Inline  
(2.29)  
B
.040  
Type 2  
Type 7  
Type 9  
.131 .050 .064 1.251  
.131 .040 .013 1.20  
.170 .040 .000 1.187 Staggered  
.013 –––  
(1.02)  
C
A
Thickness .012 .012 .012  
D
(TO TOP OF CASE)  
.012  
.080  
(2.03)  
(.30)  
Terminal assignment  
R10 - AC Coil Diagram  
28 15  
16  
14  
13  
11  
10  
8
26  
27  
22 12  
13  
11  
10  
8
25 12  
20  
19  
17  
16  
14  
21  
23  
22  
20  
19  
17  
24  
16  
14 15  
13  
11 12  
9
10  
16  
9
10  
8
9
18  
6
9
21  
6
DUAL  
COIL  
14 15  
8
7
5
10  
8
6
9
7
5
10  
8
6
9
7
5
13  
6
7
6
7
7
11 12  
5
18  
5
15  
5
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
1 POLE  
2 POLE  
3 POLE  
4 POLE  
6 POLE  
8 POLE  
4
08-2011, Rev. 0811  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay (Continued)  
PCB layout  
Bottom view on solder pins  
Suggested panel cutout for relay  
Mounting hole layout for  
terminal & mounting style 6  
Terminal Types E2 & R2  
(Omit unnecessary holes)  
Terminal Types E9 & R9  
(Omit unnecessary holes)  
.187 .002 DIA.  
(4.75 .05)  
2 HOLES  
+ .005  
.010  
.25)  
.500  
(12.70)  
TOLERANCE:  
X
DIA.  
.109  
(
.210  
(5.33)  
– .000  
+ .13  
.100  
(2.54)  
GRID  
.740  
(18.80)  
2.77  
(
)
.530  
(13.46)  
.437  
(11.10)  
– .00  
.420  
(10.67)  
.320  
(8.13)  
6
POLE  
.400  
(10.16)  
.550  
(13.97)  
.630  
(16.00)  
4
.110  
(2.79)  
.500  
2
.147 .002 DIA.  
(3.73 .05)  
POLE  
.281  
(7.14)  
(12.70)  
POLE  
.140  
(3.56)  
.281 .015  
(7.14 .38)  
.354  
(8.99)  
HOLES  
+ .004  
HOLES  
.656 .015  
.450  
(11.43)  
+ .004  
DIA.  
.056  
DIA.  
.150  
(3.81)  
.056  
- .000  
(16.66 .38)  
- .000  
.100  
(2.54)  
+ .10  
- .00  
.450  
(11.43)  
+ .10  
- .00  
X =  
1.42  
2 POLE – .343 .020  
(8.71 .51)  
(
)
1.42  
(
)
4 POLE – .562 .020  
(14.27 .51)  
6 POLE – .781 .020  
(19.84 .51)  
8 POLE – 1.000 .020  
(25.40 .51)  
Product code structure  
Type  
Typical product code  
R10  
-E  
1
Y
4
-V700  
R10 Cradle-style relay with form C contacts  
R10S Super sensitive cradle-style relay with form C contacts  
Case style  
E
R
T
Non-sealed polycarbonate dust cover (RTI)  
Wash-tight (RTIII), tape sealed plastic case  
Octal style base on non-sealed polycarbonate dust cover (terminal types 1 & 2 only; 1, 2 & 3 poles only)  
1) R10 type only, terminal code 2 or 9 only, no ground or stud  
1)  
Terminal and mounting  
1
2
6
7
9
Solder/Plug-in terminals with #3-48 mounting stud on R10-E; 8-pin octal type on R10-T  
PCB terminals (std.) 1.62mm (.064in) clearance, 31.75mm (1.25in) seated ht.; 11-pin octal type on R10-T  
Side mounting plate with #6-32 stud, solder/plug-in terminals (#3-48 stud not included)  
Narrow 1.02mm (.04in) PCB terminals, .33mm (.013in) clearance, 30.48mm (1.2in) seated ht.  
2)  
Non-shouldered, narrow 1.02mm (.04in) PCB terminals in staggered arrangement  
2) Available only on 1 through 6 pole models  
3)  
Contact style and rating  
5)  
W
X
M
Y
Z
Single contact rated 7.5A max, 300mA min. 4)  
5) 6)  
Single contact rated 5A max, 300mA min.  
Bifurcated contact rated 5A max, 300 mA min. 5) 6)  
Single contact rated 2A typ, 3A max, 100mA min.  
Bifurcated low level contacts rated 100mA typ, 2A max, 1mA min.  
P
L
Bifurcated crossbar dry circuit contacts rated 1mA typ, 3A max, dry circuit min.  
Bifurcated crossbar dry circuit contacts rated 500 microA typ, 250 mA max, dry circuit min.  
3) Ratings are at 28VDCV or 115VAC. Total load must not exceed 30A per relay.  
4) Use ungrounded frame for AC load of ≥5A. Max ratings are 7.5A at 115VAC and 4A at 28VDC for coil codes S & J  
5) Only available on R10 type, only available with coil adjustment code V, Q, S and J.  
6) Use ungrounded frame for AC load of ≥5A. Max ratings are 5A at 115VAC and 3A at 28VDC for coil codes S & J  
Number of poles  
1
2
3
1 pole  
2 pole  
3 pole  
4
6
8
4 pole (not available on R10-T)  
6 pole (not available on R10-T) 7)  
8 pole (not available on R10-T)  
8)  
7) Not available with contact code W  
8) Only available with case style E, not available with contact code W  
Coil voltage  
Coil code: please refer to coil versions table  
AC voltage Specify coil code consisting of nominal coil voltage followed by W (example: 24V)  
DC voltage Specify coil code consisting of coil adjustment code letter followed by coil resistance (example: V700)  
5
08-2011, Rev. 0811  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  
General Purpose Relays  
Industrial Relays  
Potter & Brumfield  
R10 Series Panel Plug-in Relay (Continued)  
Product Code Arrangement Material Contact Style/Rating Nom. Coil V  
Terminals & Mounting  
Part Number  
R10-E1P2-115V  
R10-E1P2-V700  
R10-E1P4-115V  
R10-E1P4-V700  
R10-E1W2-V185  
R10-E1W2-V700  
R10-E1W4-V185  
R10-E1W4-V700  
R10-E1X2-24V  
R10-E1X2-115V  
R10-E1X2-S800  
R10-E1X2-V185  
R10-E1X2-V700  
R10-E1X4-115V  
R10-E1X4-V185  
R10-E1X4-V700  
R10-E1X4-V2.5K  
R10-E1X6-115V  
R10-E1X6-V90  
2 Form C, 2 CO Au overlay Ag Bif crossbar / dry circuit  
115 VAC  
24 VDC  
115 VAC  
24 VDC  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
24 VAC  
115 VAC  
12 VDC  
Solder/plug-in w/ #3-48 mounting stud  
7-1393765-0  
6-1393765-9  
7-1393765-6  
7-1393765-5  
8-1393765-9  
9-1393765-1  
9-1393765-3  
9-1393765-5  
1-1393766-1  
1-1393766-0  
1393766-3  
4 Form C, 4 CO  
2 Form C, 2 CO  
4 Form C, 4 CO  
2 Form C, 2 CO  
AgCdO  
Single contact / 7.5A  
Single contact / 5A  
1393766-5  
1393766-9  
24 VDC  
115 VAC  
12 VDC  
24 VDC  
48 VDC  
115 VAC  
12 VDC  
24 VAC  
4 Form C, 4 CO  
1-1393766-8  
1-1393766-4  
1-1393766-7  
1-1393766-5  
2-1393766-5  
2-1393766-4  
2-1393766-2  
3-1393766-3  
3-1393766-4  
4-1393766-0  
4-1393766-4  
4-1393766-1  
3-1393766-9  
4-1393766-9  
5-1393766-6  
5-1393766-5  
5-1393766-7  
6-1393766-1  
6-1393766-0  
7-1393766-2  
7-1393766-4  
7-1393766-9  
8-1393766-1  
8-1393766-0  
8-1393766-6  
8-1393766-5  
2-1393769-8  
7-1393769-0  
7-1393769-5  
1393767-3  
6 Form C, 6 CO  
2 Form C, 2 CO  
R10-E1X6-V430  
R10-E1Y2-J1.0K  
R10-E1Y2-J2.5K  
R10-E1Y2-V185  
R10-E1Y2-V700  
R10-E1Y2-V2.5K  
R10-E1Y2-V15.0K  
Ag  
Single contact / 2A typical Not applicable  
12 VDC  
24 VDC  
48 VDC  
115 VDC  
R10-E1Y4-J10.0K 4 Form C, 4 CO  
R10-E1Y4-V52  
Not applicable  
R10-E1Y4-V2.5K  
R10-E1Y4-V700  
48 VDC  
24 VDC  
R10-E1Y6-V430  
R10-E1Y6-V1.5K  
R10-E1Z2-V185  
R10-E1Z2-V700  
R10-E1Z4-V185  
R10-E1Z4-V700  
R10-E1Z4-V2.5K  
R10-E1Z6-V430  
R10-E1Z6-V1.5K  
R10-T1P2-115V  
6 Form C, 6 CO  
2 Form C, 2 CO  
4 Form C, 4 CO  
48 VDC  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
48 VDC  
24 VDC  
48 VDC  
115 VAC  
Bifurcated / 100mA typical  
6 Form C, 6 CO  
2 Form C, 2 CO Au overlay Ag Bif crossbar / dry circuit  
R10S-E1Y1-J1.0K 1 Form C, 1 CO  
R10S-E1Y2-J5.0K 2 Form C, 2 CO  
Ag  
Single contact / 2A typical Not applicable  
R10-E2P4-V185  
R10-E2P4-V700  
R10-E2W2-V185  
R10-E2X2-V185  
R10-E2X2-V700  
R10-E2X4-V185  
R10-E2X4-V700  
R10-E2Y2-V185  
R10-E2Y2-V700  
R10-E2Y4-V185  
R10-E2Y4-V700  
4 Form C, 4 CO Au overlay Ag Bif crossbar / dry circuit  
12 VDC  
24 VDC  
12 VDC  
PCB, .064" clearance, 1.25" seated ht.  
1393767-4  
1393767-7  
2 Form C, 2 CO  
AgCdO  
Ag  
Single contact / 5A  
1-1393767-1  
1-1393767-5  
1-1393767-7  
1-1393767-8  
2-1393767-6  
2-1393767-9  
3-1393767-5  
3-1393767-6  
8-1393769-1  
24 VDC  
12 VDC  
24 VDC  
12 VDC  
24 VDC  
4 Form C, 4 CO  
2 Form C, 2 CO  
4 Form C, 4 CO  
Single contact / 2A typical  
12 VDC  
24 VDC  
R10S-E2Y1-J1.0K 1 Form C, 1 CO  
Not applicable  
6
08-2011, Rev. 0811  
Datasheets and product specification  
according to IEC 61810-1 and to be used  
only together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY