FEATURES  
CꢀTwo linear taper potentiometers  
ꢀꢁ DS1845-010 one 10k, 100 position &  
one 10k, 256 position  
SDA  
SCL  
A0  
A1  
A2  
1
2
3
4
5
6
7
14  
13  
12  
11  
10  
9
Vcc  
H0  
W1  
H1  
L1  
ꢀꢁ DS1845-050 one 10k, 100 position &  
one 50k, 256 postition  
ꢀꢁ DS1845-100 one 10k, 100 position &  
one 100k, 256 position  
WP  
GND  
W0  
L0  
Cꢀ256 bytes of EEPROM memory  
CꢀAccess to data and potentiometer control via  
an I2C compatible 2-wire interface  
CꢀExternal Write Enable pin to protect data and  
potentiometer settings  
8
14-Pin TSSOP (173 mil)  
Top View  
CꢀNonvolatile wiper storage  
A
B
C
CꢀOperates from 3V or 5V supplies  
CꢀPackaging: Flip Chip Package, 16-ball  
CSBGA, 14-pin TSSOP  
CꢀIndustrial operating temperature: -40ºC to  
+85ºC  
D
1
2
3
4
16-Ball CSBGA (4mm x 4mm)  
14-Pin Flip Chip (100-mil x 100-mil) (Not Shown)  
DESCRIPTION  
The DS1845 Dual NV Potentiometer and Memory consists of one100-position linear taper  
potentiometer, one256-position linear taper potentiometer, 256 bytes of EEPROM memory, and a 2-wire  
interface. The device provides an ideal method for setting bias voltages and currents in control  
applications using a minimum of circuitry. The EEPROM memory allows a user to store configuration  
or calibration data for a specific system or device as well as provide control of the potentiometer wiper  
settings. Any type of user information may reside in the first 248 bytes of this memory. The next two  
addresses of EEPROM memory are for potentiometer settings. Access to this EEPROM is via an  
industry standard 2-wire bus. The wiper position of the DS1845, as well as EEPROM data, can be  
hardware write-protected using the Write Protect (WP) input pin. Up to eight DS1845s can be installed  
on a single 2-wire bus. Access to an individual device is achieved by using a device address that is  
determined by the logic levels of address pins A0 though A2. Additionally, the DS1845 will operate  
from 3 volt or 5 volt supplies. Three package options are available: Flip Chip Package, 16-ball CSBGA  
and 14-pin TSSOP.  
1 of 14  
011006  
DS1845  
PIN DESCRIPTIONS  
Name TSSOP BGA  
Description  
VCC  
14  
A3  
Power Supply Terminal. The DS1845 will support supply  
voltages ranging from +2.7V to +5.5V.  
GND  
SDA  
7
1
D1  
B2  
Ground Terminal.  
2-Wire serial data interface. The serial data pin is for serial data  
transfer to and from the DS1845. The pin is open drain and may  
be wire-ORed with other open drain or open collector interfaces.  
2-Wire Serial Clock Input. The serial clock input is used to  
clock data into the DS1845 on rising edges and clock data out on  
falling edges.  
SCL  
WP  
2
6
A2  
C1  
Write Protect Input. If set to logic 0, the data in memory and the  
potentiometer wiper setting may be changed. If set to logic 1, both  
the memory and the potentiometer wiper settings will be write  
protected. The WP pin is pulled high internally.  
Address Input. Pins A0, A1, and A2 are used to specify the  
address of each DS1845 when used in a multi-dropped  
configuration. Up to eight DS1845s may be addressed on a single  
2-wire bus.  
A0  
3
A1  
A1  
A2  
H0  
4
B1  
C2  
A4  
Address Input.  
5
Address Input.  
13  
High terminal of Potentiometer 0. For both potentiometers, it is  
not required that the high terminal be connected to a potential  
greater than the low terminal. Voltage applied to the high terminal  
of each potentiometer cannot exceed VCC or go below ground.  
High terminal of Potentiometer 1.  
H1  
L0  
11  
8
B3  
D3  
Low terminal of Potentiometer 0. For both potentiometers, it is  
not required that the low terminal be connected to a potential less  
than the high terminal. Voltage applied to the low terminal of each  
potentiometer cannot exceed VCC or go below ground.  
Low terminal of Potentiometer 1.  
L1  
10  
9
C4  
D4  
W0  
Wiper terminal of Pot 0. The wiper position of Potentiometer 0  
is determined by the byte at EEPROM memory location F9h.  
Voltage applied to the wiper terminal of each potentiometer cannot  
exceed the power supply voltage, VCC, or go below ground.  
Wiper terminal of Pot 1. The wiper position of Potentiometer 1  
is determined by the byte at EEPROM memory location F8h.  
No Connect.  
W1  
12  
B4  
NC  
NC  
C3  
D2  
No Connect.  
2 of 14  
DS1845  
DS1845 BLOCK DIAGRAM Figure 1  
248 BYTES  
VCC  
GND  
EEPROM  
MEMORY  
2-WIRE  
INTERFACE  
POTENTIOMETER 0  
6 RESERVED  
BYTES  
CONTROL  
DATA  
SDA  
H0  
100  
Position  
Pot  
W0  
L0  
SCL  
WP  
1 BYTE WIPER  
SETTING  
POT 0  
A0  
A1  
A2  
POTENTIOMETER 1  
1 BYTE WIPER  
SETTING  
POT 1  
H1  
W1  
L1  
256  
Position  
Pot  
MEMORY ORGANIZATION  
The DS1845’s serial EEPROM is internally organized with 256 words of 1 byte each. Each word requires  
an 8-bit address for random word addressing. The byte at address F9h determines the wiper setting for  
potentiometer 0, which contains 100 positions. Writing values above 63h to this address sets the wiper to  
its uppermost position. The byte at address F8h determines the wiper setting for potentiometer 1, which  
contains 256 positions (00h to FFh). The factory default wiper position for both potentiometers is FFh.  
Memory locations 00h to F7h are factory programmed to 00h. Address locations FAh though FFh are  
reserved and should not be written.  
DEVICE OPERATION  
Clock and Data Transitions: The SDA pin is normally pulled high with an external resistor or device.  
Data on the SDA pin may only change during SCL low time periods. Data changes during SCL high  
periods will indicate a start or stop conditions depending on the conditions discussed below. Refer to the  
timing diagram Fig 2 for further details.  
Start Condition: A high-to-low transition of SDA with SCL high is a start condition which must  
precede any other command. Refer to the timing diagram Fig 2 for further details.  
Stop Condition: A low-to-high transition of SDA with SCL high is a stop condition. After a read  
sequence, the stop command places the DS1845 into a low-power mode. Refer to the timing diagram Fig  
2 for further details.  
Acknowledge: All address and data byte are transmitted via a serial protocol. The DS1845 pulls the  
SDA line low during the ninth clock pulse to acknowledge that it has received each word.  
Standby Mode: The DS1845 features a low-power mode that is automatically enabled after power-on,  
after a stop command, and after the completion of all internal operations.  
3 of 14  
DS1845  
2-Wire Interface Reset: After any interruption in protocol, power loss, or system reset, the following  
steps reset the DS1845.  
1. Clock up to nine cycles.  
2. Look for SDA high in each cycle while SCL is high.  
3. Create a start condition while SDA is high.  
Device Addressing: The DS1845 must receive an 8-bit device address word following a start condition  
to enable a specific device for a read or write operation. The address word is clocked into the DS1845  
MSB to LSB. The address word consists of Ah (1010) followed by A2, A1, and A0 then the R/W  
(READ/WRITE) bit. If the R/W bit is high, a read operation is initiated. The R/W is low, a write  
operation is initiated. For a device to become active, the values of A2, A1 and A0 must be the same as  
the hard-wired address pins on the DS1845. Upon a match of written and hard-wired addresses, the  
DS1845 will output a zero for one clock cycle as an acknowledge. If the address does not match the  
DS1845 returns to a low-power mode.  
Write Operations: After receiving a matching address byte with the R/W bit set low, the device goes  
into the write mode of operation. The master must transmit an 8-bit EEPROM memory address to the  
device to define the address where the data is to be written. After the reception of this byte, the DS1845  
will transmit a zero for one clock cycle to acknowledge the receipt of the address. The master must then  
transmit an 8-bit data word to be written into this address. The DS1845 will again transmit a zero for one  
clock cycle to acknowledge the receipt of the data. At this point the master must terminate the write  
operation with a stop condition. The DS1845 then enters an internally timed write process tw to the  
EEPROM memory. All inputs are disabled during this byte write cycle.  
The DS1845 is capable of an 8-byte page write. A page write is initiated the same way as a byte write,  
but the master does not send a stop condition after the 1st byte. Instead, after the slave acknowledges  
receipt of the data byte, the master can send up to seven more bytes using the same nine-clock sequence.  
The master must terminate the write cycle with a stop condition or the data clocked into the DS1845 will  
not be latched into permanent memory.  
Acknowledge Polling: Once the internally-timed write has started and the DS1845 inputs are disabled,  
acknowledge polling can be initiated. The process involves transmitting a start condition followed by the  
device address. The R/W bit signifies the type of operation that is desired. The read or write sequence  
will only be allowed to proceed if the internal write cycle has completed and the DS1845 responds with a  
zero.  
Read Operations: After receiving a matching address byte with the R/W bit set high, the device goes  
into the read mode of operation. There are three read operations: current address read, random read and  
sequential address read.  
4 of 14  
DS1845  
CURRENT ADDRESS READ  
The DS1845 has an internal address register that maintains the address used during the last read or write  
operation, incremented by one. This data is maintained as long as VCC is valid. If the most recent  
address was the last byte in memory, then the register resets to the first address. This address stays valid  
between operations as long as power is available.  
Once the device address is clocked in and acknowledged by the DS1845 with the R/W bit set to high, the  
current address data word is clocked out. The master does not respond with a zero, but does generate a  
stop condition afterwards.  
RANDOM READ  
A random read requires a dummy byte write sequence to load in the data word address. Once the device  
and data address bytes are clocked in by the master, and acknowledged by the DS1845, the master must  
generate another start condition. The master now initiates a current address read by sending the device  
address with the read/write bit set high. The DS1845 will acknowledge the device address and serially  
clocks out the data byte.  
SEQUENTIAL ADDRESS READ  
Sequential reads are initiated by either a current address read or a random address read. After the master  
receives the first data byte, the master responds with an acknowledge. As long as the DS1845 receives  
this acknowledge after a byte is read, the master may clock out additional data words from the DS1845.  
After reaching address FFh, it resets to address 00h.  
The sequential read operation is terminated when the master initiates a stop condition. The master does  
not respond with a zero.  
For a more detailed description of 2-wire theory of operation, refer to the following section.  
2-WIRE SERIAL PORT OPERATION  
The 2-wire serial port interface supports a bi-directional data transmission protocol with device  
addressing. A device that sends data on the bus is defined as a transmitter, and a device receiving data as  
a receiver. The device that controls the message is called a “master.” The devices that are controlled by  
the master are “slaves.” The bus must be controlled by a master device that generates the serial clock  
(SCL), controls the bus access, and generates the START and STOP conditions. The DS1845 operates as  
a slave on the two-wire bus. Connections to the bus are made via the open-drain I/O lines SDA and SCL.  
The following I/O terminals control the 2-wire serial port: SDA, SCL, A0, A1, A2. Timing diagrams for  
the 2-wire serial port can be found in Figures 2 and 3. Timing information for the 2-wire serial port is  
provided in the AC Electrical Characteristics table for 2-wire serial communications.  
The following bus protocol has been defined:  
-
-
Data transfer may be initiated only when the bus is not busy.  
During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in  
the data line while the clock line is HIGH will be interpreted as control signals.  
Accordingly, the following bus conditions have been defined:  
Bus not busy: Both data and clock lines remain HIGH.  
5 of 14  
DS1845  
Start data transfer: A change in the state of the data line from HIGH to LOW while the clock is HIGH  
defines a START condition.  
Stop data transfer: A change in the state of the data line from LOW to HIGH while the clock line is  
HIGH defines the STOP condition.  
Data valid: The state of the data line represents valid data when, after a START condition, the data line  
is stable for the duration of the HIGH period of the clock signal. The data on the line can be changed  
during the LOW period of the clock signal. There is one clock pulse per bit of data. Figures 2 and 3  
detail how data transfer is accomplished on the two-wire bus. Depending upon the state of the R/W bit,  
two types of data transfer are possible.  
Each data transfer is initiated with a START condition and terminated with a STOP condition. The  
number of data bytes transferred between START and STOP conditions is not limited and is determined  
by the master device. The information is transferred byte-wise and each receiver acknowledges with a 9th  
bit.  
Within the bus specifications a regular mode (100 kHz clock rate) and a fast mode (400 kHz clock rate)  
are defined. The DS1845 works in both modes.  
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the  
reception of each byte. The master device must generate an extra clock pulse which is associated with this  
acknowledge bit.  
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a  
way that the SDA line is a stable LOW during the HIGH period of the acknowledge related clock pulse.  
Of course, setup and hold times must be taken into account. A master must signal an end of data to the  
slave by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this  
case, the slave must leave the data line HIGH to enable the master to generate the STOP condition.  
1. Data transfer from a master transmitter to a slave receiver. The 1st byte transmitted by the master is  
the command/control byte. Next follows a number of data bytes. The slave returns an acknowledge bit  
after each received byte.  
2. Data transfer from a slave transmitter to a master receiver. The master transmits the 1st byte (the  
command/control byte) to the slave. The slave then returns an acknowledge bit. Next follows a  
number of data bytes transmitted by the slave to the master. The master returns an acknowledge bit  
after all received bytes other than the last byte. At the end of the last received byte, a ‘not  
acknowledge’ can be returned.  
The master device generates all serial clock pulses and the START and STOP conditions. A transfer is  
ended with a STOP condition or with a repeated START condition. Since a repeated START condition is  
also the beginning of the next serial transfer, the bus will not be released.  
6 of 14  
DS1845  
The DS1845 may operate in the following two modes:  
1. Slave receiver mode: Serial data and clock are received through SDA and SCL respectively. After  
each byte is received, an acknowledge bit is transmitted. START and STOP conditions are  
recognized as the beginning and end of a serial transfer. Address recognition is performed by  
hardware after reception of the slave (device) address and direction bit.  
2. Slave transmitter mode: The 1st byte is received and handled as in the slave receiver mode. However,  
in this mode the direction bit will indicate that the transfer direction is reversed. Serial data is  
transmitted on SDA by the DS1845 while the serial clock is input on SCL. START and STOP  
conditions are recognized as the beginning and end of a serial transfer.  
Slave Address: command/control byte is the 1st byte received following the START condition from the  
master device. The command/control byte consists of a 4-bit control code. For the DS1845, this is set as  
1010 binary for read/write operations. The next 3 bits of the command/ control byte are the device select  
bits or slave address (A2, A1, A0). They are used by the master device to select which of eight devices is  
to be accessed. When reading or writing the DS1845, the device-select bits must match the device-select  
pins (A2, A1, A0). The last bit of the command/control byte (R/W) defines the operation to be performed.  
When set to a 1 a read operation is selected, and when set to a 0 a write operation is selected.  
Following the START condition, the DS1845 monitors the SDA bus checking the device type identifier  
being transmitted. Upon receiving the 1010 control code, the appropriate device address bits, and the  
read/write bit, the slave device outputs an acknowledge signal on the SDA line.  
WRITE PROTECT  
An external pin WP (write protect) protects EEPROM data and potentiometer position from alteration in  
an application. This pin must be open or tied high to protect data from alteration.  
READING AND WRITING THE POTENTIOMETER VALUES  
Reading from and writing to the potentiometers consists of a standard read or write to EEPROM memory  
at the addresses F8h and F9h. The 8-bit value at address F9h controls the wiper setting for potentiometer  
0, which has 100 positions. The 8-bit value at address F8h controls the wiper setting of potentiometer 1,  
which has 256 positions. Potentiometer 1 may be set to any value between 00h and FFh. 00h sets the  
wiper of potentiometer 1 to its lowest value and FFh sets the wiper to its highest. Potentiometer 0 may be  
set to any value between 00h and 63h. A value of 00h sets the wiper of potentiometer 0 to its lowest  
position and 63h sets the wiper to its highest position. Any hexadecimal value is a valid address. Setting  
a value greater than the upper limit of the potentiometer’s range, 64h or greater for potentiometer 0, will  
result in setting the wiper to its highest position, but the MSB will be ignored.  
7 of 14  
DS1845  
2- WIRE PROTOCOL DATA TRANSFER PROTOCOL Figure 2  
2-WIRE AC CHARACTERISTICS Figure 3  
8 of 14  
DS1845  
ABSOLUTE MAXIMUM RATINGS*  
Voltage on Any Pin Relative to Ground  
Operating Temperature  
-0.5V to +6.0V  
-40°C to +85°C; Industrial  
0°C to +70°C  
Programming Temperature  
Storage Temperature  
-55°C to +125°C  
Soldering Temperature  
See J-STD-020 specification  
* This is a stress rating only and functional operation of the device at these or any other conditions above  
those indicated in the operation sections of this specification is not implied. Exposure to absolute  
maximum rating conditions for extended periods of time may affect reliability.  
RECOMMENDED OPERATING CONDITIONS  
(-40LC to +85LC)  
PARAMETER  
Supply Voltage  
SYMBOL  
VCC  
MIN  
+2.7  
.7 VCC  
-0.5  
TYP  
MAX  
5.5  
UNITS  
NOTES  
V
V
V
V
1
Input Logic 1  
Input Logic 0  
Resistor Inputs  
VIH  
VCC+0.5  
.3 VCC  
VCC+0.5  
1,3  
1,3  
1
VIL  
L,H,W  
-0.5  
9 of 14  
DS1845  
DC ELECTRICAL CHARACTERISTICS  
(-40°C to +85°C; VCC =2.7V to 5.5V)  
PARAMETER  
SYMBOL CONDITION  
MIN  
TYP  
MAX  
UNITS NOTES  
Supply Current  
Active  
ICC  
0.5  
mA  
12,13  
Input Leakage  
Wiper Resistance  
3V  
ILI  
RW  
-1  
+1  
A  
500  
250  
1000  
600  
5V  
Wiper Current  
IW  
2
mA  
V
Input Logic levels  
Input Logic 1  
0.7 VCC  
-0.5  
VCC+0.5  
0.3 VCC  
+10  
A0, A1, A2  
Input Logic 0  
0.4<VI/O  
Input Current each  
I/O pin  
-10  
A  
A  
<0.9VDD  
ISTBY  
2
Standby Current  
20  
30  
40  
60  
3V  
5V  
Low Level Output  
VOL1  
VOL2  
3 mA sink  
current  
0.0  
0.0  
0.4  
V
V
Voltage (SDA)  
6 mA sink  
0.6  
current  
I/O Capacitance  
CI/O  
Rwp  
10  
100  
pF  
k  
WP Internal Pull Up  
40  
65  
Resistance, Rwp  
10 of 14  
DS1845  
ANALOG RESISTOR CHARACTERISTICS (-40°C to +85°C; VCC=2.7V to 5.5V)  
PARAMETER  
SYMBOL CONDITION  
MIN  
TYP  
MAX  
UNITS NOTES  
End-to-End Resistance  
25°C  
-20  
+20  
%
Absolute Linearity  
-0.75  
-0.75  
-1.0  
+0.75  
+0.75  
+1.0  
LSB  
9
10k/100 pos.  
10k/256 pos.  
20k/256 pos.  
50k/256 pos.  
-1.5  
+1.5  
-2.25  
+2.25  
100k/256  
pos.  
Relative Linearity  
-3dB Cutoff freq.  
-0.25  
-0.5  
+0.25  
+0.5  
LSB  
10  
11  
10k/100 pos.  
all other pots  
DS1845-010  
fCUTOFF  
1
750  
MHz  
ppm/°C  
End-to-End Temp.  
Coefficient  
11 of 14  
DS1845  
AC ELECTRICAL CHARACTERISTICS  
(-40°C to 85°C , Vcc=2.7V to 5.5V)  
PARAMETER  
SYMBOL CONDITION MIN  
TYP MAX UNITS NOTES  
SCL clock frequency  
Fast Mode  
Standard Mode  
Fast Mode  
0
400  
kHz  
fSCL  
4
0
100  
Bus free time between  
STOP and START  
condition  
Hold time (repeated)  
START condition  
Low period of SCL clock  
1.3  
4.7  
s  
tBUF  
Standard Mode  
Fast Mode  
Standard Mode  
Fast Mode  
0.6  
4.0  
1.3  
4.7  
0.6  
4.0  
0
s  
s  
s  
s  
ns  
tHD:STA  
tLOW  
5
Standard Mode  
Fast Mode  
High period of SCL clock  
Data hold time  
tHIGH  
Standard Mode  
Fast Mode  
0.9  
tHD:DAT  
tSU:DAT  
6
Standard Mode  
Fast Mode  
0
Data set-up time  
100  
250  
0.6  
4.7  
20 +  
Standard Mode  
Fast Mode  
Start set-up time  
s  
tSU:STA  
tR  
Standard Mode  
Fast Mode  
Rise time of both SDA  
and SCL signals  
300  
ns  
7
7
Standard Mode 0.1CB  
1000  
Fall time of both SDA  
and SCL signals  
Set-up time for STOP  
condition  
Capacitive load for each  
bus line  
EEPROM write time  
Fast Mode  
20 +  
300  
ns  
tF  
Standard Mode 0.1CB  
300  
Fast Mode  
0.6  
4.0  
s  
tSU:STO  
Standard Mode  
CB  
tW  
400  
pF  
7
8
5
ms  
NOTES:  
1. All voltages are referenced to ground.  
2. ISTBY specified with VCC equal 3.0V and 5.0V and control port logic pins are driven to the appropriate  
logic levels. Appropriate logic levels specify that logic inputs are within a 0.5V of ground or VCC for  
the corresponding inactive state.  
3. I/O pins of fast mode devices must not obstruct the SDA and SCL lines if VCC is switched off.  
4. A fast mode device can be used in a standard mode system, but the requirement tSU:DAT > 250 ns must  
then be met. This will automatically be the case if the device does not stretch the LOW period of the  
SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next  
data bit to the SDA line tRMAX + tSU:DAT = 1000 + 250 = 1250 ns before the SCL line is released.  
5. After this period, the first clock pulse is generated.  
6. The maximum tHD:DAT has only to be met if the device does not stretch the LOW period (tLOW) of the  
SCL signal.  
12 of 14  
DS1845  
7. C - total capacitance of one bus line in picofarads. Timing referenced to 0.9VCC and 0.1VCC.  
B
8. EEPROM write begins after a stop condition occurs.  
9. Absolute linearity is used to measure expected wiper voltage as determined by wiper position.  
10. Relative linearity is used to determine the change of wiper voltage between two adjacent wiper  
positions.  
11. When used as a rheostat or variable resister the temperature coefficient applies: 750 ppm/°C. When  
used as a voltage divider or potentiometer, the effective temperature coefficient approaches  
30 ppm/°C.  
12. ICC specified with SDA pin open.  
13. Maximum Icc is dependent on clock rates.  
13 of 14  
DS1845  
ORDERING INFORMATION  
ORDERING  
NUMBER  
PACKAGE  
ORERATING  
TEMPERATURE  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
VERSION  
Pot 0/Pot 1  
10 kꢂꢄ10 kꢂ  
10 kꢂꢄ10 kꢂ  
10 kꢂꢄ10 kꢂ  
10 kꢂꢄ10 kꢂ  
10 kꢂꢄ50 kꢂ  
10 kꢂꢄ50 kꢂ  
10 kꢂꢄ50 kꢂ  
10 kꢂꢄ50 kꢂ  
10 kꢂꢄ100 kꢂ  
10 kꢂꢄ100 kꢂ  
10 kꢂꢄ100 kꢂ  
10 kꢂꢄ100 kꢂ  
10 kꢂꢄ100 kꢂ  
10 kꢂꢄ10 kꢂ  
DS1845E-010  
14 PIN TSSOP (173 MIL)  
14 PIN TSSOP/TAPE & REEL  
14 PIN FLIP CHIP  
16 BALL CSBGA (4X4 MM)  
14 PIN TSSOP (173 MIL)  
14 PIN TSSOP/TAPE & REEL  
14 PIN FLIP CHIP  
16 BALL CSBGA (4X4 MM)  
14 PIN TSSOP (173 MIL)  
14 PIN TSSOP/TAPE & REEL  
14 PIN FLIP CHIP  
16 BALL CSBGA (4X4 MM)  
14 PIN TSSOP LF (173 MIL)  
16 BALL CSBGA/T&R LF (4X4  
MM)  
16 BALL CSBGA/T&R  
16 BALL CSBGA LF (4X4 MM)  
14 PIN TSSOP/T&R LF (173  
MIL)  
16 BALL CSBGA LF (4X4 MM)  
14 PIN TSSOP LF (173 MIL)  
14 PIN TSSOP/T&R LF  
14 PIN TSSOP/T&R LF (173  
MIL)  
16 BALL CSBGA LF (4X4 MM)  
14 PIN TSSOP LF  
DS1845E-010/T&R  
DS1845X-010/T&R  
DS1845B-010  
DS1845E-050  
DS1845E-050/T&R  
DS1845X-050/T&R  
DS1845B-050  
DS1845E-100  
DS1845E-100/T&R  
DS1845X-100/T&R  
DS1845B-100  
DS1845E-100+  
DS1845B-010+T&R  
DS1845B-010/T&R  
DS1845B-100+  
DS1845E-100+T&R  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
10 kꢂꢄ10 kꢂ  
10 kꢂꢄ100 kꢂ  
10 kꢂꢄꢅꢆ0 kꢂ  
DS1845B-010+  
DS1845E-010+  
DS1845E-010+T&R  
DS1845E-050+T&R  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
10 kꢂꢄꢅ0 kꢂ  
10 kꢂꢄꢅ0 kꢂ  
10 kꢂꢄꢅ0 kꢂ  
10 kꢂꢄꢇ0 kꢂ  
DS1845B-050+  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
-40ºC TO +85ºC  
10 kꢂꢄꢇꢆ kꢂ  
10 kꢂꢄꢇ0 kꢂ  
10 kꢂꢄꢈ0 kꢂ  
10 kꢂꢄꢇ0 kꢂ  
10 kꢂꢄꢇ0 kꢂ  
DS1845E-050+  
DS1845B-020  
16 BALL CSBGA (4X4 MM)  
16 BALL CSBGA/T&R  
16 BALL CSBGA/T&R LF (4X4  
MM)  
DS1845B-050/T&R  
DS1845B-050+T&R  
DS1845E-020  
14 PIN TSSOP  
-40ºC TO +85ºC  
10 kꢂꢄꢈ0 kꢂ  
*LF = lead free  
14 of 14  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY