DS1923-F5 [MAXIM]
Hygrochron Temperature/Humidity Logger iButton with 8KB Data-Log Memory; 温度/湿度记录仪iButton ,具有8KB数据记录存储器![DS1923-F5](http://pdffile.icpdf.com/pdf1/p00137/img/icpdf/DS192_757364_icpdf.jpg)
型号: | DS1923-F5 |
厂家: | ![]() |
描述: | Hygrochron Temperature/Humidity Logger iButton with 8KB Data-Log Memory |
文件: | 总55页 (文件大小:633K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
19-4991; Rev 3; 10/09
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
♦ Quick Access to Alarmed Devices Through 1-Wire
General Description
Conditional Search Function
®
The DS1923 temperature/humidity logger iButton is a
♦ 512 Bytes of General-Purpose Memory Plus 64
rugged, self-sufficient system that measures temperature
and/or humidity and records the result in a protected
memory section. The recording is done at a user-defined
rate. A total of 8192 8-bit readings or 4096 16-bit readings,
taken at equidistant intervals ranging from 1s to 273hr, can
be stored. Additionally, 512 bytes of SRAM store applica-
tion-specific information and 64 bytes store calibration
data. A mission to collect data can be programmed to
begin immediately, after a user-defined delay, or after a
temperature alarm. Access to the memory and control
functions can be password protected. The DS1923 is con-
figured and communicates with a host-computing device
Bytes of Calibration Memory
♦ Two-Level Password Protection of All Memory
and Configuration Registers
♦ Communicates to Host with a Single Digital Signal
at Up to 15.4kbps at Standard Speed or Up to
125kbps in Overdrive Mode Using 1-Wire Protocol
♦ Individually Calibrated in an NIST-Traceable Chamber
♦ Calibration Coefficients for Temperature and
Humidity Factory Programmed Into Nonvolatile
(NV) Memory
®
through the serial 1-Wire protocol, which requires only a
Common iButton Features
single data lead and a ground return. Every DS1923 is
factory lasered with a guaranteed unique 64-bit registra-
tion number that allows for absolute traceability. The
durable stainless-steel package is highly resistant to envi-
ronmental hazards such as dirt, moisture, and shock.
Accessories permit the DS1923 to be mounted on almost
any object, including containers, pallets, and bags.
♦ Digital Identification and Information by
Momentary Contact
♦ Unique Factory-Lasered 64-Bit Registration Number
Ensures Error-Free Device Selection and Absolute
Traceability Because No Two Parts Are Alike
♦ Built-In Multidrop Controller for 1-Wire Net
♦ Chip-Based Data Carrier Compactly Stores Information
♦ Data Can Be Accessed While Affixed to Object
♦ Button Shape is Self-Aligning with Cup-Shaped Probes
Applications
Temperature and Humidity Logging in Food
Preparation and Processing
♦ Durable Stainless-Steel Case Engraved with
Transportation of Temperature-Sensitive and
Humidity-Sensitive Goods, Industrial Production
Registration Number Withstands Harsh Environments
♦ Easily Affixed with Self-Stick Adhesive Backing,
Latched by Its Flange, or Locked with a Ring
Pressed Onto Its Rim
Warehouse Monitoring
Environmental Studies/Monitoring
Features
♦ Presence Detector Acknowledges When Reader
♦ Digital Hygrometer Measures Humidity with 8-Bit
First Applies Voltage
(0.6%RH) or 12-Bit (0.04%RH) Resolution
♦ Meets UL 913 (4th Edit.); Intrinsically Safe Apparatus:
Approved Under Entity Concept for Use in Class I,
Division 1, Group A, B, C, and D Locations
♦ Operating Range: -20°C to +85°C; 0 to 100%RH
(see Safe Operating Range Graph)
♦ Automatically Wakes Up, Measures Temperature
and/or Humidity, and Stores Values in 8KB of
Data-Log Memory in 8-Bit or 16-Bit Format
Ordering Information
PART
TEMP RANGE
PIN-PACKAGE
♦ Digital Thermometer Measures Temperature with
DS1923-F5#
-20°C to +85°C
F5 iButton
8-Bit (0.5°C) or 11-Bit (0.0625°C) Resolution
#Denotes a RoHS-compliant device that may include lead(Pb)
that is exempt under the RoHS requirements.
♦ Temperature Accuracy Better Than 0.5°C from
-10°C to +65°C with Software Correction
Examples of Accessories
♦ Built-In Capacitive Polymer Humidity Sensor for
Humidity Logging
PART
ACCESSORY
Self-Stick Adhesive Pad
Multipurpose Clip
Mounting Lock Ring
Snap-In FOB
♦ Hydrophobic Filter Protects Sensor Against Dust, Dirt,
DS9096P
DS9101
Contaminants, and Water Droplets/Condensation
♦ Sampling Rate from 1s Up to 273hr
DS9093RA
DS9093A
DS9092
♦ Programmable Recording Start Delay After Elapsed
Time or Upon a Temperature Alarm Trip Point
iButton Probe
♦ Programmable High and Low Trip Points for
Pin Configuration appears at end of data sheet.
Temperature and Humidity Alarms
iButton and 1-Wire are registered trademarks of Maxim Integrated Products, Inc.
________________________________________________________________ Maxim Integrated Products
1
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
ABSOLUTE MAXIMUM RATINGS
IO Voltage Range Relative to GND ..........................-0.3V to +6V
IO Sink Current....................................................................20mA
Operating Temperature
and Humidity Range ................-20°C to +85°C, 0 to 100%RH*
Storage Temperature
and Humidity Range ................-40°C to +85°C, 0 to 100%RH*
*See the Safe Operating Range graph.
DS1923
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
PUP
= +3.0V to +5.25V, T = -20°C to +85°C.)
A
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
IO PIN: GENERAL DATA
1-Wire Pullup Resistance
Input Capacitance
R
(Notes 1, 2)
(Note 3)
2.2
800
10
kꢀ
pF
μA
V
PUP
C
100
6
IO
Input Load Current
I
L
IO pin at V
PUP
High-to-Low Switching Threshold
Input Low Voltage
V
(Notes 4, 5)
(Notes 1, 6)
(Notes 4, 7)
(Note 8)
0.4
3.2
0.3
3.4
N/A
0.4
TL
V
V
IL
Low-to-High Switching Threshold
Switching Hysteresis
V
0.7
V
TH
HY
OL
V
V
0.09
V
Output Low Voltage
At 4mA (Note 9)
V
Standard speed, R
= 2.2kꢀ
5
2
PUP
Overdrive speed, R
= 2.2kꢀ
PUP
Recovery Time
(Note 1)
t
t
μs
REC
REH
Overdrive speed directly prior to reset
pulse, R = 2.2kꢀ
5
PUP
Rising-Edge Hold-Off Time
Time-Slot Duration (Note 1)
(Note 10)
0.6
65
8
2.0
μs
μs
Standard speed
t
Overdrive speed, V
> 4.5V
SLOT
PUP
Overdrive speed (Note 11)
IO PIN: 1-Wire RESET, PRESENCE-DETECT CYCLE
Standard speed, V
9.5
> 4.5V
480
690
48
720
720
80
80
60
63.5
7
PUP
Standard speed (Note 11)
Overdrive speed, V > 4.5V
Reset Low Time (Note 1)
t
μs
RSTL
PUP
Overdrive speed (Note 11)
Standard speed, V > 4.5V
70
15
PUP
Presence-Detect High Time
t
μs
μs
Standard speed (Note 11)
Overdrive speed (Note 11)
15
PDH
2
Standard speed, V
Standard speed
Overdrive speed
> 4.5V
1.5
1.5
0.15
5
PUP
Presence-Detect Fall Time
(Note 12)
t
8
FPD
1
2
_______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
ELECTRICAL CHARACTERISTICS (continued)
(V
PUP
= +3.0V to +5.25V, T = -20°C to +85°C.)
A
PARAMETER
SYMBOL
CONDITIONS
Standard speed, V > 4.5V
MIN
60
60
7
TYP
MAX
240
287
24
UNITS
PUP
Standard speed (Note 11)
Overdrive speed, V > 4.5V (Note 11)
Presence-Detect Low Time
t
μs
PDL
PUP
Overdrive speed (Note 11)
7
28
Standard speed, V
Standard speed
Overdrive speed
> 4.5V
65
71.5
8
75
PUP
Presence-Detect Sample Time
(Note 1)
t
μs
75
MSP
9
IO PIN: 1-Wire WRITE
Standard speed
60
6
120
12
Write-Zero Low Time
(Note 1)
t
μs
μs
Overdrive speed, V
> 4.5V (Note 11)
W0L
PUP
Overdrive speed (Note 11)
Standard speed
7.5
5
12
15 - ꢁ
1.95 - ꢁ
Write-One Low Time
(Notes 1, 13)
t
W1L
Overdrive speed
1
IO PIN: 1-Wire READ
Standard speed
Overdrive speed
Standard speed
Overdrive speed
5
1
15 - ꢂ
1.95 - ꢂ
15
Read Low Time
(Notes 1, 14)
t
μs
μs
RL
t
t
+ ꢂ
Read Sample Time
(Notes 1, 14)
RL
RL
t
MSR
+ ꢂ
1.95
REAL-TIME CLOCK (RTC)
Min/
Month
Accuracy
+25°C
-3
+3
Frequency Deviation
ꢃ
F
-20°C to +85°C
-300
+60
ppm
TEMPERATURE CONVERTER
8-bit mode (Note 15)
16-bit mode (11 bits)
30
75
Conversion Time
t
ms
s
CONV
240
600
Thermal Response Time
Constant
ꢄ
iButton package (Note 16)
(Notes 15, 17, 18, 19)
(Notes 15, 17, 18, 19)
130
RESP
ꢃꢅ
Conversion Error Without
Software Correction
See the Temperature
Accuracy graph
°C
°C
Conversion Error with Software
Correction
See the Temperature
Accuracy graph
ꢃꢅ
HUMIDITY CONVERTER (Note 20)
Humidity Response Time
Constant
ꢄ
Slow moving air (Note 21)
30
s
RH
8
0.64
0
12
12
Bits
%RH
%RH
RH Resolution
RH Range
(Note 22)
(Note 23)
0.04
0.04
100
_______________________________________________________________________________________
3
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
ELECTRICAL CHARACTERISTICS (continued)
(V
PUP
= +3.0V to +5.25V, T = -20°C to +85°C.)
A
PARAMETER
SYMBOL
CONDITIONS
With software correction
(Notes 18, 19, 24, 25, 26)
With software correction (Note 18)
(Notes 27, 28)
MIN
TYP
MAX
UNITS
RH Accuracy and
Interchangeability
5
%RH
RH Nonlinearity
RH Hysteresis
RH Repeatability
< 1
0.5
0.5
DS1923
%RH
%RH
(Note 29)
%RH/
year
Long-Term Stability
At 50%RH (Note 30)
< 1.0
Note 1: System requirement.
Note 2: Maximum allowable pullup resistance is a function of the number of 1-Wire devices in the system and 1-Wire recovery
times. The specified value here applies to systems with only one device and with the minimum 1-Wire recovery times. For
more heavily loaded systems, an active pullup such as that in the DS2480B may be required.
Note 3: Capacitance on the data pin could be 800pF when V
is first applied. If a 2.2kΩ resistor is used to pull up the data line,
PUP
2.5μs after V
has been applied, the parasite capacitance does not affect normal communications.
PUP
Note 4:
Note 5: Voltage below which, during a falling edge on IO, a logic 0 is detected.
Note 6: The voltage on IO must be less than or equal to V whenever the master drives the line low.
V and V are a function of the internal supply voltage.
TL TH
ILMAX
Note 7: Voltage above which, during a rising edge on IO, a logic 1 is detected.
Note 8: After V is crossed during a rising edge on IO, the voltage on IO must drop by V to be detected as logic 0.
TH
HY
Note 9: The I-V characteristic is linear for voltages less than 1V.
Note 10: The earliest recognition of a negative edge is possible at t
after V has been previously reached.
TH
REH
Note 11: Numbers in bold are not in compliance with the published iButton standards. See the Comparison Table.
Note 12: Interval during the negative edge on IO at the beginning of a presence-detect pulse between the time at which the voltage
is 90% of V
and the time at which the voltage is 10% of V
.
PUP
PUP
Note 13: ε in Figure 13 represents the time required for the pullup circuitry to pull the voltage on IO up from V to V
.
TH
IL
Note 14: δ in Figure 13 represents the time required for the pullup circuitry to pull the voltage on IO up from V to the input high
IL
threshold of the bus master.
Note 15: To conserve battery power, use 8-bit temperature logging whenever possible.
Note 16: This number was derived from a test conducted by Cemagref in Antony, France, in July 2000:
www.cemagref.fr/English/index.htm Test Report No. E42.
Note 17: For software-corrected accuracy, assume correction using calibration coefficients with calibration equations for error
compensation.
Note 18: Software correction for humidity and temperature is handled automatically using the 1-Wire Viewer Software package
available at: http://www.ibutton.com.
Note 19: Warning: Not for use as the sole method of measuring or tracking temperature and/or humidity in products and articles
that could affect the health or safety of persons, plants, animals, or other living organisms, including but not limited to
foods, beverages, pharmaceuticals, medications, blood and blood products, organs, and flammable and combustible
products. User shall assure that redundant (or other primary) methods of testing and determining the handling methods,
quality, and fitness of the articles and products should be implemented. Temperature and/or humidity tracking with this
product, where the health or safety of the aforementioned persons or things could be adversely affected, is only recom-
mended when supplemental or redundant information sources are used. Data-logger products are 100% tested and cali-
brated at time of manufacture by Maxim to ensure that they meet all data sheet parameters, including temperature
accuracy. User shall be responsible for proper use and storage of this product. As with any sensor-based product, user
shall also be responsible for occasionally rechecking the accuracy of the product to ensure it is still operating properly.
Note 20: All humidity specifications are determined at +25°C except where specifically indicated.
Note 21: Response time is determined by measuring the 1/e point as the device transitions from 40%RH to 90%RH or 90%RH to
40%RH, whichever is slower. Test was performed at 5L/min airflow.
Note 22: All DS1923 humidity measurements are 12-bit readings. Missioning determines 8-bit or 16-bit data logging. Battery life-
time is the same no matter what RH resolution is logged.
Note 23: Reliability studies have shown that the device survives a minimum of 1000 cycles of condensation and drying, but this
product is not guaranteed for extended use in condensing environments.
4
_______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
ELECTRICAL CHARACTERISTICS (continued)
(V
PUP
= +3.0V to +5.25V, T = -20°C to +85°C.)
A
Note 24: Software-corrected accuracy is accomplished using the method detailed in the Software Correction Algorithm for
Temperature section.
Note 25: Every DS1923 device is measured and calibrated in a controlled, NIST-traceable RH environment.
Note 26: Higher accuracy versions may be available. Contact the factory for details.
Note 27: If this device is exposed to a high humidity environment (> 70%RH), and then exposed to a lower RH environment, the
device reads high for a period of time. The device typically reads within +0.5%RH at 20%RH, 30 minutes after being
exposed to continuous 80%RH for 30 minutes.
Note 28: All capacitive RH sensors can change their reading depending upon how long they have spent at high (> 70%RH) or low
RH (< 20%RH). This effect is called saturation drift and can be compensated through software, as described in the
Software Saturation Drift Compensation section.
Note 29: Individual RH readings always include a noise component (repeatability). To minimize measurement error, average as
many samples as is reasonable.
Note 30: Like all relative humidity sensors, when exposed to contaminants and/or conditions toward the limits of the safe operating
range, accuracy degradation can result (see the Safe Operating Range graph). For maximum long-term stability, the sen-
sor should not be exposed or subjected to organic solvents, corrosive agents (e.g., strong acids, SO , H SO , CI , HCL,
2
2
4
2
H S) and strong bases (i.e., compounds with a pH greater than 7). Dust settling on the filter surface does not affect the
2
sensor performance except to possibly decrease the speed of response. For more information on the RH sensor’s toler-
ance to chemicals visit: http://content.honeywell.com/sensing/prodinfo/humiditymoisture/technical/c15_144.pdf.
COMPARISON TABLE
LEGACY VALUES
STANDARD SPEED OVERDRIVE SPEED
(μs) (μs)
DS1923 VALUES
STANDARD SPEED
(μs)
OVERDRIVE SPEED
(μs)
PARAMETER
MIN
61
MAX
MIN
7
MAX
MIN
65*
690
15
MAX
MIN
9.5
70
2
MAX
t
t
t
t
t
(including t
)
(undefined)
(undefined)
60
(undefined)
(undefined)
720
(undefined)
SLOT
REC
480
15
48
2
80
6
80
7
RSTL
PDH
PDL
63.5
60
240
8
24
16
60
287
7
28
12
60
120
6
60
120
7.5
W0L
*Intentional change; longer recovery time requirement due to modified 1-Wire front-end.
Note: Numbers in bold are not in compliance with the published iButton standards.
iButton CAN PHYSICAL SPECIFICATION
SIZE
See the Package Information section.
WEIGHT
Ca. 5.0 grams
Meets UL 913 (4th Edit.); Intrinsically Safe Apparatus, approval under Entity Concept for use in Class I,
Division 1, Group A, B, C, and D Locations.
SAFETY
_______________________________________________________________________________________
5
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Safe Operating Range
100
80
60
40
20
0
DS1923
SAFE OPERATING ZONE
STORAGE
ONLY
-40
-20
0
20
40
60
80
TEMPERATURE (°C)
Temperature Accuracy
2.0
1.5
1.0
0.5
0
UNCORRECTED MAXIMUM ERROR
SW CORRECTED MAXIMUM ERROR
SW CORRECTED MINIMUM ERROR
UNCORRECTED MINIMUM ERROR
-0.5
-1.0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
NOTE: THE GRAPHS ARE BASED ON 11-BIT DATA.
6
_______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Minimum Lifetime vs. Temperature, Slow Sampling (Temperature Only)
EVERY MINUTE
EVERY 3 MINUTES
NO SAMPLES
EVERY 10 MINUTES
OSCILLATOR OFF
EVERY 60 MINUTES
10
9
8
7
6
5
4
3
2
1
0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
EVERY MINUTE
EVERY 3 MINUTES
EVERY 10 MINUTES
NO SAMPLES
EVERY 30 MINUTES
OSCILLATOR OFF
EVERY 60 MINUTES
EVERY 300 MINUTES
10
9
8
7
6
5
4
3
2
1
0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
_______________________________________________________________________________________
7
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Minimum Lifetime vs. Temperature, Fast Sampling (Temperature Only)
EVERY SECOND
EVERY 3 SECONDS
EVERY 60 SECONDS
EVERY 10 SECONDS
EVERY 30 SECONDS
350
300
250
200
150
100
50
DS1923
0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
EVERY SECOND
EVERY 3 SECONDS
EVERY 60 SECONDS
EVERY 10 SECONDS
EVERY 30 SECONDS
100
80
60
40
20
0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
8
_______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Minimum Lifetime vs. Temperature, Slow Sampling
(Temperature with Humidity)
EVERY MINUTE
EVERY 3 MINUTES
NO SAMPLES
EVERY 10 MINUTES
OSCILLATOR OFF
EVERY 60 MINUTES
10
9
8
7
6
5
4
3
2
1
0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
Minimum Lifetime vs. Temperature, Fast Sampling
(Temperature with Humidity)
EVERY SECOND
EVERY 3 SECONDS
EVERY 60 SECONDS
EVERY 10 SECONDS
EVERY 30 SECONDS
350
300
250
200
150
100
50
0
-20
-10
0
10
20
30
40
50
60
70
80
TEMPERATURE (°C)
_______________________________________________________________________________________
9
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Minimum Product Lifetime vs. Sample Rate (Temperature Only)
10
0°C
+40°C
+60°C
DS1923
+75°C
1
+85°C
0.1
0.01
0.01
0.1
1
10
100
MINUTES BETWEEN SAMPLES
NOTE: WITH HUMIDITY LOGGING ACTIVATED, THE LIFETIME IS REDUCED BY LESS THAN 11% FOR THE SAMPLE RATES OF 3MIN. AND SLOWER, AND BY A
MAXIMUM OF 20% FOR SAMPLE RATES OF 1MIN. AND FASTER.
10
0°C
+40°C
+60°C
+75°C
1
+85°C
0.1
0.01
0.001
0.01
0.1
1
10
100
MINUTES BETWEEN SAMPLES
NOTE: WITH HUMIDITY LOGGING ACTIVATED, THE LIFETIME IS REDUCED BY A MAXIMUM OF 4%. THE INCREMENTAL ENERGY CONSUMED BY HUMIDITY
LOGGING IS INDEPENDENT OF THE HUMIDITY LOGGING RESOLUTION.
10 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Figure 2 shows the hierarchical structure of the 1-Wire
protocol. The bus master must first provide one of the
Detailed Description
The DS1923 is an ideal device to monitor for extended
eight ROM function commands: Read ROM, Match
ROM, Search ROM, Conditional Search ROM, Skip
ROM, Overdrive-Skip ROM, Overdrive-Match ROM, or
Resume. Upon completion of an Overdrive-ROM com-
mand executed at standard speed, the device enters
overdrive mode, where all subsequent communication
occurs at a higher speed. The protocol required for
these ROM function commands is described in Figure
11. After a ROM function command is successfully exe-
cuted, the memory and control functions become
accessible and the master can provide any one of the
eight available commands. The protocol for these mem-
ory and control function commands is described in
Figure 9. All data is read and written least significant
bit first.
periods of time the temperature and humidity of any
object it is attached to or shipped with, such as fresh
produce, medical drugs and supplies, and for use in
refrigerators and freezers, as well as for logging climat-
ic data during the transport of sensitive objects and
critical processes such as curing. A 1.27mm diameter
hole in the lid of the device allows for air to reach the
humidity sensor. The rest of the electronics inside the
DS1923 is sealed so that it is not exposed to ambient
humidity. Note that the initial sealing level of the
DS1923 achieves the equivalent of IP56. Aging and use
conditions can degrade the integrity of the seal over
time, so for applications with significant exposure to liq-
uids, sprays, or other similar environments, it is recom-
mended to place the Hygrochron™ under a shield to
protect it (refer to Application Note 4126: Understanding
the IP (Ingress Protection) Ratings of iButton Data
Loggers and Capsule). The hydrophobic filter may not
protect the DS1923 from destruction in the event of full
submersion in liquid. Software for setup and data
retrieval through the 1-Wire interface is available for free
download from the iButton website (www.ibutton.com).
This software also includes drivers for the serial and USB
port of a PC and routines to access the general-purpose
memory for storing application-specific or equipment-
specific data files.
Parasite Power
The block diagram (Figure 1) shows the parasite-pow-
ered circuitry. This circuitry “steals” power whenever
the IO input is high. IO provides sufficient power as
long as the specified timing and voltage requirements
are met. The advantages of parasite power are two-
fold: 1) By parasiting off this input, battery power is
conserved, and 2) if the battery is exhausted for any
reason, the ROM can still be read.
64-Bit Lasered ROM
Each DS1923 contains a unique ROM code that is 64
bits long. The first 8 bits are a 1-Wire family code. The
next 48 bits are a unique serial number. The last 8 bits
are a cyclic redundancy check (CRC) of the first 56 bits
(see Figure 3 for details). The 1-Wire CRC is generated
using a polynomial generator consisting of a shift regis-
ter and XOR gates as shown in Figure 4. The polynomi-
Overview
The block diagram in Figure 1 shows the relationships
between the major control and memory sections of the
DS1923. The device has six main data components:
64-bit lasered ROM; 256-bit scratchpad; 512-byte gen-
eral-purpose SRAM; two 256-bit register pages of time-
keeping, control, status, and counter registers and
passwords; 64 bytes of calibration memory; and 8192
bytes of data-logging memory. Except for the ROM and
the scratchpad, all other memory is arranged in a sin-
gle linear address space. The data-logging memory,
counter registers, and several other registers are read
only for the user. Both register pages are write protect-
ed while the device is programmed for a mission. The
password registers, one for a read password and
another one for a read/write password, can only be writ-
ten, never read.
8
5
4
al is X + X + X + 1. Additional information about the
1-Wire CRC is available in Application Note 27:
Understanding and Using Cyclic Redundancy Checks
with Maxim iButton Products.
The shift register bits are initialized to 0. Then, starting
with the least significant bit of the family code, one bit
at a time is shifted in. After the 8th bit of the family code
has been entered, the serial number is entered. After
the last bit of the serial number has been entered, the
shift register contains the CRC value. Shifting in the 8
bits of CRC returns the shift register to all 0s.
Hygrochron is a trademark of Maxim Integrated Products, Inc.
______________________________________________________________________________________ 11
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
ROM
FUNCTION
CONTROL
64-BIT
LASERED
ROM
PARASITE-POWERED
CIRCUITRY
1-Wire PORT IO
DS1923
256-BIT
SCRATCHPAD
MEMORY
FUNCTION
CONTROL
3V LITHIUM
DS1923
GENERAL-PURPOSE
SRAM
(512 BYTES)
INTERNAL
32.768kHz
TIMEKEEPING,
CONTROL REGISTERS,
AND COUNTERS
REGISTER PAGES
(64 BYTES)
OSCILLATOR
CALIBRATION MEMORY
(64 BYTES)
THERMAL
SENSE
ADC1
HUMIDITY
SENSOR AND
ADC2
CONTROL
LOGIC
DATA-LOG MEMORY
8KB
Figure 1. Block Diagram
12 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
1-Wire NET
BUS
MASTER
OTHER DEVICES
DS1923
COMMAND LEVEL:
AVAILABLE COMMANDS:
DATA FIELD AFFECTED:
READ ROM
64-BIT ROM, RC-FLAG
MATCH ROM
64-BIT ROM, RC-FLAG
SEARCH ROM
64-BIT ROM, RC-FLAG
1-Wire ROM
FUNCTION COMMANDS
CONDITIONAL SEARCH ROM
SKIP ROM
64-BIT ROM, RC-FLAG, ALARM FLAGS, SEARCH CONDITIONS
RC-FLAG
RESUME
RC-FLAG
OVERDRIVE-SKIP ROM
OVERDRIVE-MATCH ROM
RC-FLAG, OD-FLAG
64-BIT ROM, RC-FLAG, OD-FLAG
WRITE SCRATCHPAD
256-BIT SCRATCHPAD, FLAGS
READ SCRATCHPAD
256-BIT SCRATCHPAD
COPY SCRATCHPAD WITH PW
READ MEMORY WITH PW AND CRC
CLEAR MEMORY WITH PW
512-BYTE DATA MEMORY, REGISTERS, FLAGS, PASSWORDS
MEMORY, REGISTERS, PASSWORDS
MISSION TIMESTAMP, MISSION SAMPLES COUNTER,
START DELAY, ALARM FLAGS, PASSWORDS
MEMORY ADDRESSES 020Ch TO 020Fh
FLAGS, TIMESTAMP, MEMORY ADDRESSES
020Ch TO 020Fh (WHEN LOGGING)
FLAGS
DS1923-SPECIFIC
MEMORY/CONTROL FUNCTION
COMMANDS
FORCED CONVERSION
START MISSION WITH PW
STOP MISSION WITH PW
Figure 2. Hierarchical Structure for 1-Wire Protocol
MSB
LSB
LSB
8-BIT
CRC CODE
8-BIT FAMILY CODE
(41h)
48-BIT SERIAL NUMBER
MSB
LSB MSB
LSB MSB
Figure 3. 64-Bit Lasered ROM
8
5
4
POLYNOMIAL = X + X + X + 1
1ST
2ND
3RD
4TH
5TH
6TH
7TH
8TH
STAGE
STAGE
STAGE
STAGE
STAGE
STAGE
STAGE
STAGE
0
1
2
3
4
5
6
7
8
X
X
X
X
X
X
X
X
X
INPUT DATA
Figure 4. 1-Wire CRC Generator
______________________________________________________________________________________ 13
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
of the calibration memory page stores an 8-bit CRC of
Memory
Figure 5 shows the DS1923 memory map. Pages 0 to
15 contain 512 bytes of general-purpose SRAM. The
various registers to set up and control the device fill
pages 16 and 17, called register pages 1 and 2 (see
Figure 6 for details). Pages 18 and 19 can be used as
storage space for calibration data. The data-log log-
ging memory starts at address 1000h (page 128) and
extends over 256 pages. The memory pages 20 to 127
are reserved for future extensions. The scratchpad is
an additional page that acts as a buffer when writing to
the SRAM memory or the register pages. The calibra-
tion memory holds data from the device calibration that
can be used to further improve the accuracy of temper-
ature and humidity readings. See the Software
Correction Algorithm sections for details. The last byte
the preceding 31 bytes. Page 19 is an exact copy of
the data in page 18. While the user can overwrite the
calibration memory, this is not recommended. See the
Security by Password section for ways to protect the
memory. The access type for the register pages is reg-
ister-specific and depends on whether the device is
programmed for a mission. Figure 6 shows the details.
The data-log memory is read only for the user. It is writ-
ten solely under supervision of the on-chip control
logic. Due to the special behavior of the write access
logic (write scratchpad, copy scratchpad), it is recom-
mended to only write full pages at a time. This also
applies to the register pages. See the Address
Registers and Transfer Status section for details.
DS1923
32-BYTE INTERMEDIATE STORAGE
SCRATCHPAD
ADDRESS
32-BYTE GENERAL-PURPOSE SRAM
(R/W)
0000h TO 001Fh
PAGE 0
PAGES 1 TO 15
PAGE 16
0020h TO 01FFh
0200h TO 021Fh
0220h TO 023Fh
0240h TO 025Fh
0260h TO 027Fh
0280h TO 0FFFh
1000h TO 2FFFh
GENERAL-PURPOSE SRAM (R/W)
32-BYTE REGISTER PAGE 1
32-BYTE REGISTER PAGE 2
PAGE 17
CALIBRATION MEMORY PAGE 1 (R/W)
CALIBRATION MEMORY PAGE 2 (R/W)
(RESERVED FOR FUTURE EXTENSIONS)
DATA-LOG MEMORY (READ ONLY)
PAGE 18
PAGE 19
PAGES 20 TO 127
PAGES 128 TO 383
Figure 5. Memory Map
14 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
ADDRESS
0200h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
FUNCTION
ACCESS*
0
0
10 Seconds
10 Minutes
Single Seconds
Single Minutes
0201h
20 Hour
AM/PM
Real-
Time Clock
Registers
0202h
0203h
0204h
0
0
12/24
10 Hour
Single Hours
Single Date
R/W
R
0
0
10 Date
10
Months
CENT
0
Single Months
Single Years
0205h
0206h
0207h
0208h
0209h
020Ah
020Bh
020Ch
020Dh
020Eh
020Fh
10 Years
Low Byte
Sample
Rate
R/W
R/W
R/W
R
R
R
R
R
R
0
0
High Byte
Low Threshold
High Threshold
Low Threshold
High Threshold
Temperature
Alarms
Humidity
Alarms
Low Byte
0
0
0
0
0
Latest
Temperature
High Byte
Low Byte
High Byte
Latest
Humidity
R
Temperature
Alarm
0210h
0211h
0
1
0
1
0
1
0
0
1
0
1
ETHA
EHHA
ETLA
EHLA
R/W
R/W
R
R
Enable
Humidity
Alarm
1
Enable
0212h
0213h
0214h
0215h
0
1
0
1
1
1
0
SUTA
1
0
RO
1
0
0
TLFS
HLF
0
EHSS
EHL
THF
MIP
EOSC
ETL
TLF
0
RTC Control R/W
R
R
R
R
Mission
R/W
HLFS
HHF
Control
BOR
1
Alarm Status
R
R
General
Status
0
WFTA MEMCLR
0216h
0217h
0218h
Low Byte
Center Byte
High Byte
Start
Delay
Counter
R/W
R
*The left entry in the ACCESS column is valid between missions. The right entry shows the applicable access type while a
mission is in progress.
Figure 6. Register Pages Map
______________________________________________________________________________________ 15
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
ADDRESS
0219h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
FUNCTION
ACCESS*
0
0
10 Seconds
10 Minutes
Single Seconds
Single Minutes
021Ah
20 Hour
AM/PM
021Bh
021Ch
021Dh
0
0
12/24
10 Hour
Single Hours
Single Date
Mission
Timestamp
R
R
9
0
0
10 Date
10
Months
CENT
0
Single Months
Single Years
021Eh
021Fh
0220h
0221h
0222h
0223h
0224h
0225h
0226h
0227h
0228h
…
10 Years
(No Function; Reads 00h)
Low Byte
—
R
R
R
R
Mission
Samples
Counter
Center Byte
High Byte
Low Byte
Device
Samples
Counter
R
R
Center Byte
High Byte
Configuration Code
EPW
Flavor
R
R
R
PW Control
R/W
First Byte
…
Read
Access
Password
W
W
R
—
—
R
022Fh
0230h
…
Eighth Byte
First Byte
…
Full
Access
Password
0237h
0238h
…
Eighth Byte
(No function; all these bytes read 00h)
—
023Fh
*The left entry in the ACCESS column is valid between missions. The right entry shows the applicable access type while a
mission is in progress.
Figure 6. Register Pages Map (continued)
16 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Sample Rate
Detailed Register Descriptions
The content of the Sample Rate register (addresses
Timekeeping and Calendar
0206h, 0207h) specifies the time elapse (in seconds if
The RTC and calendar information is accessed by
EHSS = 1, or minutes if EHSS = 0) between two tem-
reading/writing the appropriate bytes in the register
perature/humidity-logging events. The sample rate can
page, address 0200h to 0205h. For readings to be
be any value from 1 to 16,383, coded as an unsigned
valid, all RTC registers must be read sequentially start-
14-bit binary number. If EHSS = 1, the shortest time
ing at address 0200h. Some of the RTC bits are set to
between logging events is 1s and the longest (sample
0. These bits always read 0 regardless of how they are
rate = 3FFFh) is 4.55hr. If EHSS = 0, the shortest is
written. The number representation of the RTC registers
1min and the longest time is 273.05hr (sample rate =
is binary-coded decimal (BCD) format.
3FFFh). The EHSS bit is located in the RTC Control reg-
The DS1923’s RTC can run in either 12hr or 24hr mode.
Bit 6 of the Hours register (address 0202h) is defined
as the 12hr or 24hr mode select bit. When high, the
12hr mode is selected. In the 12hr mode, bit 5 is the
AM/PM bit with logic 1 being PM. In the 24hr mode, bit
5 is the 20hr bit (20hr to 23hr). The CENT bit, bit 7 of
the Months register, can be written by the user. This bit
changes its state when the years counter transitions
from 99 to 00.
ister at address 0212h. It is important that the user sets
the EHSS bit accordingly while setting the Sample Rate
register. Writing a sample rate of 0000h results in a
sample rate = 0001h, causing the DS1923 to log the
temperature either every minute or every second
depending upon the state of the EHSS bit.
The calendar logic is designed to automatically com-
pensate for leap years. For every year value that is
either 00 or a multiple of 4, the device adds a 29th of
February. This works correctly up to (but not including)
the year 2100.
RTC Registers Bitmap
ADDRESS
0200h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0
0
10 Seconds
10 Minutes
Single Seconds
0201h
Single Minutes
Single Hours
20 Hour
AM/PM
0202h
0
12/24
10 Hour
0203h
0204h
0205h
0
0
0
10 Date
Single Date
Single Months
Single Years
CENT
0
10 Months
10 Years
Note: During a mission, there is only read access to these registers. Bit cells marked “0” always read 0 and cannot be written to 1.
Sample Rate Register Bitmap
ADDRESS
0206h
BIT 7
BIT 6
BIT 5
BIT 4
Sample Rate Low
Sample Rate High
BIT 3
BIT 2
BIT 1
BIT 0
0207h
0
0
Note: During a mission, there is only read access to these registers. Bit cells marked “0” always read 0 and cannot be written to 1.
______________________________________________________________________________________ 17
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Because the temperature alarm threshold is only one
Temperature Conversion
The DS1923’s temperature range begins at -20°C and
ends at +85°C. Temperature values are represented as
an 8-bit or 16-bit unsigned binary number with a resolu-
tion of 0.5°C in 8-bit mode and 0.0625°C in 16-bit
mode.
byte, the resolution or temperature increment is limited to
0.5°C. The TALM value must be converted into hexadec-
imal format before it can be written to one of the
Temperature Alarm Threshold registers (Low Alarm
address 0208h; High Alarm address 0209h).
Independent of the conversion mode (8-bit or 16-bit),
only the most significant byte of a temperature conver-
sion is used to determine whether an alarm is generated.
The higher temperature byte TRH is always valid. In
16-bit mode, only the three highest bits of the lower
byte TRL are valid. The five lower bits all read 0. TRL is
undefined if the device is in 8-bit temperature mode. An
out-of-range temperature reading is indicated as 00h or
0000h when too cold and FFh or FFE0h when too hot.
DS1923
Humidity Conversion
In addition to temperature, the DS1923 can log humidi-
ty data in an 8-bit or 16-bit format. Humidity values are
represented as 8-bit or 16-bit unsigned binary numbers
with a resolution of 0.64%RH in the 8-bit mode and
0.04%RH in the 16-bit mode.
With TRH and TRL representing the decimal equivalent
of a temperature reading, the temperature value is cal-
culated as:
The DS1923 reads data from its humidity sensor when-
ever a Forced Conversion command is executed (see
the Memory/Control Function Commands section) or
during a mission if the device is set up to log humidity
data. Regardless of its setup, the DS1923 always reads
16 bits from the humidity sensor. The result of the latest
humidity reading is found at address 020Eh (low byte)
and 020Fh (high byte). The most significant bit read
from the humidity sensor can always be found as H11
at address 020Fh. Due to the 12-bit digital output of the
humidity sensor, the lower 4 bits in 16-bit format are
undefined.
ϑ(°C) = TRH/2 - 41 + TRL/512 (16-bit mode,
TLFS = 1, see address 0213h)
ϑ(°C) = TRH/2 - 41 (8-bit mode, TLFS = 0,
see address 0213h)
This equation is valid for converting temperature read-
ings stored in the data-log memory as well as for data
read from the Latest Temperature Conversion Result
register.
To specify the temperature alarm thresholds, the previ-
ous equations are resolved to:
TALM = 2 x ϑ(°C) + 82
Latest Temperature Conversion Result Register Bitmap
ADDRESS
020Ch
BIT 7
T2
BIT 6
T1
BIT 5
T0
BIT 4
0
BIT 3
0
BIT 2
0
BIT 1
0
BIT 0
0
BYTE
TRL
020Dh
T10
T9
T8
T7
T6
T5
T4
T3
TRH
Table 1. Temperature Conversion Examples
TRH
TRL
MODE
ꢀ(°C)
HEX
54h
17h
54h
17h
DECIMAL
HEX
DECIMAL
8-Bit
8-Bit
84
23
84
23
—
—
—
—
0
1.0
-29.5
16-Bit
16-Bit
00h
60h
1.000
96
-29.3125
Table 2. Temperature Alarm Threshold Examples
TALM
ꢀ(°C)
HEX
85h
3Eh
DECIMAL
133
25.5
-10.0
62
18 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Latest Humidity Conversion Result Register Bitmap
ADDRESS
020Eh
BIT 7
H3
BIT 6
H2
BIT 5
H1
BIT 4
H0
BIT 3
X
BIT 2
X
BIT 1
X
BIT 0
X
BYTE
HRL
020Fh
H11
H10
H9
H8
H7
H6
H5
H4
HRH
During a mission, if humidity logging is enabled, the
HRH byte (H11 to H4) is always recorded. The HRL
byte is only recorded if the DS1923 is set up for 16-bit
humidity logging. The logging mode (8-bit or 16-bit) is
selected through the HLFS bit at the Mission Control
register, address 0213h.
With HRH and HRL representing the decimal equivalent
of a humidity reading, the actual humidity is calculated
according to the algorithms shown in the table below.
16-BIT MODE, HLFS = 1
8-BIT MODE, HLFS = 0
(N/A)
IVAL = (HRH x 256 + HRL)/16
Round IVAL down to the nearest integer; this eliminates the
undefined 4 bits of HRL.
ADVAL = IVAL x 5.02/4096
ADVAL = HRH x 5.02/256
HUMIDITY(%RH) = (ADVAL - 0.958)/0.0307
The result is a raw humidity reading that needs to be
corrected to achieve the specified accuracy. See the
Software Correction Algorithm for Humidity section for
further details.
mode (8-bit or 16-bit), only the most significant byte of a
humidity conversion is used to determine whether an
alarm is generated. The alarm thresholds are applied to
the raw humidity readings. Therefore, if software correc-
tion is used, the effect of the software correction is to be
reversed before calculating a humidity alarm threshold.
For example, let the desired alarm threshold be 60%RH.
The 60% threshold may correspond to a raw reading of
65%RH (i.e., before correction). To set a 60%RH (after
correction) threshold, the HALM value then needs to be
calculated for 65%RH.
To specify the humidity alarm thresholds, the equation
needs to be resolved to:
ADVAL = HUMIDITY(%RH) x 0.0307 + 0.958
HALM = ADVAL x 256/5.02
Round HALM to the nearest integer.
The HALM value needs to be converted into hexadeci-
mal before it can be written to one of the Humidity Alarm
Threshold registers (Low Alarm address 020Ah; High
Alarm address 020Bh). Independent of the conversion
These examples do not include the effects of software
correction.
Table 3. Humidity Conversion Examples
HRH
HRL
MODE
HUMIDITY (%RH)
HEX
B5h
67h
B5h
67h
DECIMAL
181
HEX
ꢀ
DECIMAL
8-bit
ꢀ
ꢀ
12
48
84.41
34.59
84.89
34.70
8-bit
103
ꢀ
16-bit
16-bit
181
C0h
30h
103
Table 4. Humidity Alarm Threshold Examples
HALM
HUMIDITY (%RH)
HEX
97h
58h
DECIMAL
151
65
25
88
______________________________________________________________________________________ 19
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Temperature Sensor Control Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0210h
0
0
0
0
0
0
ETHA
ETLA
Note: During a mission, there is only read access to this register. Bits 2 to 7 have no function. They always read 0 and cannot be written to 1.
Humidity Sensor Control Register Bitmap
DS1923
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0211h
1
1
1
1
1
1
EHHA
EHLA
Note: During a mission, there is only read access to this register. Bits 2 to 7 have no function. They always read 1 and cannot be written to 0.
RTC Control Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0212h
0
0
0
0
0
0
EHSS
EOSC
Note: During a mission, there is only read access to this register. Bits 2 to 7 have no function. They always read 0 and cannot be written to 1.
alarm signaling is enabled. The bits EHLA and EHHA
that enable the humidity alarm are located in the
Humidity Sensor Control register. The corresponding
alarm flags HLF and HHF are found in the Alarm Status
register at address 0214h.
Temperature Sensor Alarm
The DS1923 has two Temperature Alarm Threshold
registers (address 0208h, 0209h) to store values that
determine whether a critical temperature has been
reached. A temperature alarm is generated if the
device measures an alarming temperature and the
alarm signaling is enabled. The bits ETLA and ETHA
that enable the temperature alarm are located in the
Temperature Sensor Control register. The temperature
alarm flags TLF and THF are found in the Alarm Status
register at address 0214h.
Bit 1: Enable Humidity High Alarm (EHHA). This bit
controls whether, during a mission, the humidity high
alarm flag (HHF) can be set, if a value from the humidi-
ty sensor is equal to or higher than the value in the
Humidity High Alarm Threshold register. If EHHA is 1,
humidity high alarms are enabled. If EHHA is 0, humidi-
ty high alarms are not generated.
Bit 1: Enable Temperature High Alarm (ETHA). This
bit controls whether, during a mission, the temperature
high alarm flag (THF) can be set, if a temperature con-
version results in a value equal to or higher than the
value in the Temperature High Alarm Threshold register.
If ETHA is 1, temperature high alarms are enabled. If
ETHA is 0, temperature high alarms are not generated.
Bit 0: Enable Humidity Low Alarm (EHLA). This bit
controls whether, during a mission, the humidity low
alarm flag (HLF) can be set, if a value from the humidity
sensor is equal to or lower than the value in the
Humidity Low Alarm Threshold register. If EHLA is 1,
humidity low alarms are enabled. If EHLA is 0, humidity
low alarms are not generated.
Bit 0: Enable Temperature Low Alarm (ETLA). This
bit controls whether, during a mission, the temperature
low alarm flag (TLF) can be set, if a temperature con-
version results in a value equal to or lower than the
value in the Temperature Low Alarm Threshold register.
If ETLA is 1, temperature low alarms are enabled. If
ETLA is 0, temperature low alarms are not generated.
RTC Control
To minimize the power consumption of a DS1923, the
RTC oscillator should be turned off when the device is
not in use. The oscillator on/off bit is located in the RTC
Control register. This register also includes the EHSS
bit, which determines whether the sample rate is speci-
fied in seconds or minutes.
Humidity Alarm
The DS1923 has two Humidity Alarm Threshold regis-
ters (address 020Ah, 020Bh) to store values that deter-
mine whether humidity readings can generate an
alarm. Such an alarm is generated if the humidity data
read from the sensor qualifies for an alarm and the
Bit 1: Enable High-Speed Sample (EHSS). This bit
controls the speed of the sample rate counter. When set
to logic 0, the sample rate is specified in minutes. When
set to logic 1, the sample rate is specified in seconds.
20 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Bit 0: Enable Oscillator (EOSC). This bit controls the
ning, overwriting previously collected data. If this bit is
0, the logging and conversions stop once the data-log
memory is full. However, the RTC continues to run and
the MIP bit remains set until the Stop Mission command
is performed.
crystal oscillator of the RTC. When set to logic 1, the
oscillator starts. When written to logic 0, the oscillator
stops and the device is in a low-power data-retention
mode. This bit must be 1 for normal operation. A
Forced Conversion or Start Mission command automati-
cally starts the RTC by changing the EOSC bit to
logic 1.
Bit 3: Humidity Logging Format Selection (HLFS).
This bit specifies the format used to store humidity
readings in the data-log memory. If this bit is 0, the
data is stored in 8-bit format. If this bit is 1, the 16-bit
format is used (higher resolution). With 16-bit format,
the most significant byte is stored at the lower address.
Mission Control
The DS1923 is set up for its operation by writing appro-
priate data to its special function registers, which are
located in the two register pages. The settings in the
Mission Control register determine whether temperature
and/or humidity is logged, which format (8 or 16 bits)
applies, and whether old data can be overwritten by
new data once the data-log memory is full. An addition-
al control bit can be set to tell the DS1923 to wait with
logging data until a temperature alarm is encountered.
Bit 2: Temperature Logging Format Selection
(TLFS). This bit specifies the format used to store tem-
perature readings in the data-log memory. If this bit is
0, the data is stored in 8-bit format. If this bit is 1, the
16-bit format is used (higher resolution). With 16-bit for-
mat, the most significant byte is stored at the lower
address.
Bit 1: Enable Humidity Logging (EHL). To set up the
DS1923 for a humidity-logging mission, this bit must be
set to logic 1. If temperature and humidity logging are
enabled, the recorded humidity values begin at
address 2000h (TLFS = HLFS) or 1A00h (TLFS = 0;
HLFS = 1) or 2400h (TLFS = 1; HLFS = 0). If only
humidity logging is enabled, the recorded values are
stored starting at address 1000h. Since humidity data
has little scientific value without knowing the tempera-
ture, typically both humidity and temperature logging
are enabled (i.e., ETL and EHL are set to 1).
Bit 5: Start Mission Upon Temperature Alarm
(SUTA). This bit specifies whether a mission begins
immediately (includes delayed start) or if a temperature
alarm is required to start the mission. If this bit is 1, the
device performs an 8-bit temperature conversion at the
selected sample rate and begins with data logging only
if an alarming temperature (high alarm or low alarm)
was found. The first logged temperature is when the
alarm occurred. However, the Mission Sample Counter
does not increment. The start upon temperature alarm
function is only available if temperature logging is
enabled (ETL = 1).
Bit 0: Enable Temperature Logging (ETL). To set up
the device for a temperature-logging mission, this bit
must be set to logic 1. To successfully start a mission,
ETL or EHL must be 1. If temperature logging is
enabled, the recorded temperature values are always
stored starting at address 1000h.
Bit 4: Rollover Control (RO). This bit controls whether,
during a mission, the data-log memory is overwritten
with new data or whether data logging is stopped once
the data-log memory is full. Setting this bit to 1 enables
the rollover and data logging continues at the begin-
Mission Control Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0213h
1
1
SUTA
RO
HLFS
TLFS
EHL
ETL
Note: During a mission, there is only read access to this register. Bits 6 and 7 have no function. They always read 1 and cannot be written to 0.
______________________________________________________________________________________ 21
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Alarm Status Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0214h
BOR
1
1
1
HHF
HLF
THF
TLF
Note: There is only read access to this register. Bits 4 to 6 have no function. They always read 1. All five alarm status bits are cleared
simultaneously when the Clear Memory command is invoked. See the Memory and Control Functions section for details.
DS1923
General Status Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0215h
1
1
0
WFTA
MEMCLR
0
MIP
0
Note: There is only read access to this register. Bits 0, 2, 5, 6, and 7 have no function.
during a mission revealing a temperature equal to or
lower than the value in the Temperature Low Alarm reg-
ister. A forced conversion can affect the TLF bit. This
bit can also be set with the initial alarm in the SUTA = 1
mode.
Alarm Status
The fastest way to determine whether a programmed
temperature or humidity threshold was exceeded during
a mission is through reading the Alarm Status register.
In a networked environment that contains multiple
DS1923 iButtons, the devices that encountered an alarm
can quickly be identified by means of the Conditional
Search command (see the 1-Wire ROM Function
Commands section). The humidity and temperature
alarm only occurs if enabled (see the Temperature
Sensor Alarm and Humidity Alarm sections). The BOR
alarm is always enabled.
General Status
The information in the General Status register tells the
host computer whether a mission-related command
was executed successfully. Individual status bits indi-
cate whether the DS1923 is performing a mission, wait-
ing for a temperature alarm to trigger the logging of
data or whether the data from the latest mission has
been cleared.
Bit 7: Battery-On Reset Alarm (BOR). If this bit reads
1, the device has performed a power-on reset. This
indicates that the device has experienced a shock big
enough to interrupt the internal battery power supply.
The device can still appear functional, but it has lost its
factory calibration. Any data found in the data-log
memory should be disregarded.
Bit 4: Waiting for Temperature Alarm (WFTA). If this
bit reads 1, the mission start upon temperature alarm
was selected and the Start Mission command was suc-
cessfully executed, but the device has not yet experi-
enced the temperature alarm. This bit is cleared after a
temperature alarm event, but is not affected by the
Clear Memory command. Once set, WFTA remains set
if a mission is stopped before a temperature alarm
occurs. To clear WFTA manually before starting a new
mission, set the high temperature alarm (address
0209h) to -40°C and perform a forced conversion.
Bit 3: Humidity High Alarm Flag (HHF). If this bit
reads 1, there was at least one humidity reading during
a mission revealing a value equal to or higher than the
value in the Humidity High Alarm register. A forced
conversion can affect the HHF bit.
Bit 2: Humidity Low Alarm Flag (HLF). If this bit reads
1, there was at least one humidity reading during a mis-
sion revealing a value equal to or lower than the value
in the Humidity Low Alarm register. A forced conversion
can affect the HLF bit.
Bit 3: Memory Cleared (MEMCLR). If this bit reads 1,
the Mission Timestamp, Mission Samples Counter, and
all the alarm flags of the Alarm Status register have
been cleared in preparation of a new mission.
Executing the Clear Memory command clears these
memory sections. The MEMCLR bit returns to 0 as soon
as a new mission is started by using the Start Mission
command. The memory must be cleared for a mission
to start.
Bit 1: Temperature High Alarm Flag (THF). If this bit
reads 1, there was at least one temperature conversion
during a mission revealing a temperature equal to or
higher than the value in the Temperature High Alarm
register. A forced conversion can affect the THF bit.
This bit can also be set with the initial alarm in the
SUTA = 1 mode.
Bit 1: Mission in Progress (MIP). If this bit reads 1, the
device has been set up for a mission and this mission is
still in progress. The MIP bit returns from logic 1 to logic
0 when a mission is ended. See the Start Mission with
Password and Stop Mission with Password sections.
Bit 0: Temperature Low Alarm Flag (TLF). If this bit
reads 1, there was at least one temperature conversion
22 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Mission Start Delay Counter Register Bitmap
ADDRESS
0216h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
Delay Low Byte
0217h
Delay Center Byte
Delay High Byte
0218h
Note: During a mission, there is only read access to this register.
Mission Timestamp Register Bitmap
ADDRESS
0219h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0
0
10 Seconds
10 Minutes
Single Seconds
021Ah
Single Minutes
Single Hours
20 Hours
AM/PM
021Bh
0
12/24
10 Hours
021Ch
021Dh
021Eh
0
0
0
10 Date
Single Date
Single Months
Single Years
CENT
0
10 Months
10 Years
Note: There is only read access to this register.
Mission Samples Counter Register Bitmap
ADDRESS
0220h
BIT 7
BIT 6
BIT 5
BIT 4
Low Byte
BIT 3
BIT 2
BIT 1
BIT 0
0221h
Center Byte
High Byte
0222h
Note: There is only read access to this register. Note that when both the internal temperature and humidity logging are enabled, the
two log readings are counted as one event in the Mission Sample Counter and Device Sample Counter.
Mission Start Delay
The content of the Mission Start Delay Counter register
tells how many minutes must expire from the time a mis-
sion was started until the first measurement of the mis-
sion takes place (SUTA = 0) or until the device starts
testing the temperature for a temperature alarm (SUTA =
1). The Mission Start Delay register is stored as an
unsigned 24-bit integer number. The maximum delay is
16,777,215min, equivalent to 11,650 days or roughly
31yr. If the start delay is nonzero and the SUTA bit is set
to 1, first the delay must expire before the device starts
testing for temperature alarms to begin logging data.
Mission Timestamp
The Mission Timestamp register indicates the date and time
of the first temperature and humidity sample of the mission.
There is only read access to the Mission Timestamp register.
Mission Progress Indicator
Depending on settings in the Mission Control register
(address 0213h), the DS1923 logs temperature and/or
humidity in 8-bit or 16-bit format. The description of the
ETL and EHL bit explains where the device stores data
in its data-log memory. The Mission Samples Counter
register together with the starting address and the log-
ging format (8 or 16 bits) provide the information to iden-
tify valid blocks of data that have been gathered during
the current (MIP = 1) or latest mission (MIP = 0). See the
Data-Log Memory Usage section for an illustration. Note
that when SUTA = 1, the Mission Samples Counter does
not increment when the first sample is logged.
For a typical mission, the Mission Start Delay is 0. If a
mission is too long for a single DS1923 to store all read-
ings at the selected sample rate, one can use several
devices and set the Mission Start Delay for the second
device to start recording as soon as the memory of the
first device is full, and so on. The RO bit in the Mission
Control register (address 0213h) must be set to 0 to
prevent overwriting of collected data once the data-log
memory is full.
The number read from the Mission Samples Counter indi-
cates how often the DS1923 woke up during a mission to
measure temperature and/or humidity. The number for-
mat is 24-bit unsigned integer. The Mission Samples
Counter is reset through the Clear Memory command.
______________________________________________________________________________________ 23
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Device Samples Counter Register Bitmap
ADDRESS
0223h
BIT 7
BIT 6
BIT 5
BIT 4
Low Byte
BIT 3
BIT 2
BIT 1
BIT 0
0224h
Center Byte
High Byte
0225h
Note: There is only read access to this register.
DS1923
Device Configuration Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
PART
0
0
0
0
1
0
0
1
1
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
DS2422
DS1923
DS1922L
DS1922T
DS1922E
0226h
Note: There is only read access to this register.
Password Control Register Bitmap
ADDRESS
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
0227h
EPW
Note: During a mission, there is only read access to this register.
Other Indicators
The Device Samples Counter register is similar to the
Mission Samples Counter register. During a mission this
counter increments whenever the DS1923 wakes up to
measure and log data and when the device is testing
for a temperature alarm in SUTA mode. Between mis-
sions, the counter increments whenever the Forced
Conversion command is executed. This way the Device
Samples Counter register functions like a gas gauge for
the battery that powers the iButton.
Security by Password
The DS1923 is designed to use two passwords that
control read access and full access. Reading from or
writing to the scratchpad as well as the Forced
Conversion command does not require a password.
The password must be transmitted immediately after
the command code of the memory or control function. If
password checking is enabled, the password transmit-
ted is compared to the passwords stored in the device.
The data pattern stored in the Password Control regis-
ter determines whether password checking is enabled.
The Device Samples Counter register is reset to zero
when the iButton is assembled. The counter increments
a couple of times during final test. The number format is
24-bit unsigned integer. The maximum number that can
be represented in this format is 16,777,215.
To enable password checking, the EPW bits need to
form a binary pattern of 10101010 (AAh). The default
pattern of EPW is different from AAh. If the EPW pattern
is different from AAh, any pattern is accepted as long
as it has a length of exactly 64 bits. Once enabled,
changing the passwords and disabling password
checking requires the knowledge of the current full-
access password.
The code in the Device Configuration register allows the
master to distinguish between the DS2422 chip and dif-
ferent versions of the DS1922 iButtons. The Device
Configuration Register table shows the codes assigned
to the various devices.
24 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Read-Access Password Register Bitmap
ADDRESS
0228h
0229h
…
BIT 7
RP7
BIT 6
RP6
BIT 5
RP5
BIT 4
RP4
BIT 3
RP3
BIT 2
RP2
BIT 1
RP1
BIT 0
RP0
RP15
RP14
RP13
RP12
RP11
RP10
RP9
RP8
…
022Eh
022Fh
RP55
RP63
RP54
RP62
RP53
RP61
RP52
RP60
RP51
RP59
RP50
RP58
RP49
RP57
RP48
RP56
Note: There is only write access to this register. Attempting to read the password reports all zeros. The password cannot be
changed while a mission is in progress.
Full-Access Password Register Bitmap
ADDRESS
0230h
0231h
…
BIT 7
FP7
BIT 6
FP6
BIT 5
FP5
BIT 4
FP4
BIT 3
FP3
BIT 2
FP2
BIT 1
FP1
BIT 0
FP0
FP15
FP14
FP13
FP12
FP11
FP10
FP9
FP8
…
0236h
0237h
FP55
FP63
FP54
FP62
FP53
FP61
FP52
FP60
FP51
FP59
FP50
FP58
FP49
FP57
FP48
FP56
Note: There is only write access to this register. Attempting to read the password reports all zeros. The password cannot be
changed while a mission is in progress.
Before enabling password checking, passwords for
read-only access as well as for full access
(read/write/control) must be written to the password
registers. Setting up a password or enabling/dis-
abling the password checking is done in the same
way as writing data to a memory location; only the
address is different. Since they are located in the
same memory page, both passwords can be rede-
fined at the same time.
The Full Access Password must be transmitted exactly
in the sequence FP0, FP1…FP62, FP63. It affects the
commands Read Memory with CRC, Copy Scratchpad,
Clear Memory, Start Mission, and Stop Mission. The
DS1923 executes the command only if the password
transmitted by the master was correct or if password
checking is not enabled.
Due to the special behavior of the write-access logic,
the Password Control register and both passwords
must be written at the same time. When setting up new
passwords, always verify (read back) the scratchpad
before sending the Copy Scratchpad command. After a
new password is successfully copied from the scratch-
pad to its memory location, erase the scratchpad by fill-
ing it with new data (Write Scratchpad command).
Otherwise, a copy of the passwords remains in the
scratchpad for public read access.
The Read Access Password must be transmitted exact-
ly in the sequence RP0, RP1…RP62, RP63. This pass-
word only applies to the Read Memory with CRC
command. The DS1923 delivers the requested data
only if the password transmitted by the master was cor-
rect or if password checking is not enabled.
______________________________________________________________________________________ 25
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
If alarm signaling is desired, the temperature alarm
Data-Log Memory Usage
and/or humidity alarm low and high thresholds must be
defined. See the Temperature Conversion section for
information on how to convert a temperature value into
the binary code to be written to the threshold registers.
See the Humidity Conversion section for information on
determining the thresholds for the humidity alarm. In
addition, the temperature alarm and/or humidity alarm
must be enabled for the low and/or high threshold. This
makes the device respond to a Conditional Search
command (see the1-Wire ROM Function Commands
section), provided that an alarming condition has been
encountered.
Once set up for a mission, the DS1923 logs the temper-
ature and/or humidity measurements at equidistant time
points entry after entry in its data-log memory. The
data-log memory can store 8192 entries in 8-bit format
or 4096 entries in 16-bit format (Figure 7a). If tempera-
ture as well as humidity are logged, both in the same
format, the memory is split into two equal sections that
can store 4096 8-bit entries or 2048 16-bit entries
(Figure 7b). If the device is set up to log data in differ-
ent formats, e. g., temperature in 8-bit and humidity in
16-bit format, the memory is split into blocks of different
size, accommodating 2560 entries for either data
source (Figure 7c). In this case, the upper 256 bytes
are not used. In 16-bit format, the higher 8 bits of an
entry are stored at the lower address. Knowing the
starting time point (Mission Timestamp) and the interval
between temperature measurements, one can recon-
struct the time and date of each measurement.
DS1923
The setting of the RO bit (rollover enable) and sample
rate depends on the duration of the mission and the
monitoring requirements. If the most recently logged
data is important, the rollover should be enabled (RO =
1). Otherwise one should estimate the duration of the
mission in minutes and divide the number by 8192 (sin-
gle channel 8-bit format) or 4096 (single channel 16-bit
format, two channels 8-bit format) or 2048 (two channels
16-bit format) or 2560 (two channels, one 8-bit and one
16-bit format) to calculate the value of the sample rate
(number of minutes between conversions). If the esti-
mated duration of a mission is 10 days (= 14400min), for
example, then the 8192-byte capacity of the data-log
memory would be sufficient to store a new 8-bit value
every 1.8min (110s). If the data-log memory of the
DS1923 is not large enough to store all readings, one
can use several devices and set the Mission Start Delay
to values that make the second device start logging as
soon as the memory of the first device is full, and so on.
The RO-bit needs to be set to 0 to disable rollover that
would otherwise overwrite the logged data.
There are two alternatives to the way the DS1923
behaves after the data-log memory is filled with data.
The user can program the device to either stop any fur-
ther recording (disable rollover) or overwrite the previ-
ously recorded data (enable rollover), one entry at a
time, starting again at the beginning of the respective
memory section. The contents of the Mission Samples
Counter in conjunction with the sample rate and the
Mission Timestamp allow reconstructing the time
points of all values stored in the data-log memory. This
gives the exact history over time for the most recent
measurements taken. Earlier measurements cannot be
reconstructed.
Missioning
After the RO bit and the Mission Start Delay are set, the
sample rate must be written to the Sample Rate regis-
ter. The sample rate can be any value from 1 to 16,383,
coded as an unsigned 14-bit binary number. The
fastest sample rate is one sample per second (EHSS =
1, sample rate = 0001h) and the slowest is one sample
every 273.05hr (EHSS = 0, sample rate = 3FFFh). To
get one sample every 6min, for example, the sample
rate value must be set to 6 (EHSS = 0) or 360 decimal
(equivalent to 0168h at EHSS = 1).
The typical task of the DS1923 iButton is recording tem-
perature and/or humidity. Before the device can per-
form this function, it needs to be set up properly. This
procedure is called missioning.
First, the DS1923 must have its RTC set to a valid time
and date. This reference time can be the local time, or,
when used inside of a mobile unit, UTC (also called
GMT, Greenwich Mean Time), or any other time stan-
dard that was agreed upon. The RTC oscillator must be
running (EOSC = 1). The memory assigned to store the
Mission Timestamp, Mission Samples Counter, and
alarm flags must be cleared using the Memory Clear
command. To enable the device for a mission, at least
one of the enable logging bits (ETL, EHL) must be set
to 1. These are general settings that must be made in
any case, regardless of the type of object to be moni-
tored and the duration of the mission.
If there is a risk of unauthorized access to the DS1923
or manipulation of data, one should define passwords
for read access and full access. Before the passwords
become effective, their use must be enabled. See the
Security by Password section for more details.
26 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
ETL = 1; EHL = 0 OR ETL = 0; EHL = 1
TLFS = HLFS = 0
ETL = 1; EHL = 0 OR ETL = 0; EHL = 1
TLFS = HLFS = 1
1000h
8192
1000h
4096
8-BIT ENTRIES
TEMPERATURE
OR
16-BIT ENTRIES
TEMPERATURE
OR
WITH 16-BIT FORMAT, THE MOST SIGNIFICANT
BYTE IS STORED AT THE LOWER ADDRESS.
HUMIDITY DATA
HUMIDITY DATA
2FFFh
2FFFh
Figure 7a. 1-Channel Logging
ETL = EHL = 1
ETL = EHL = 1
TLFS = HLFS = 0
TLFS = HLFS = 1
1000h
1000h
TEMPERATURE
TEMPERATURE
2048
4096
8-BIT ENTRIES
16-BIT ENTRIES
1FFFh
2000h
1FFFh
2000h
WITH 16-BIT FORMAT, THE MOST SIGNIFICANT
BYTE IS STORED AT THE LOWER ADDRESS.
HUMIDITY DATA
4096
HUMIDITY DATA
2048
8-BIT ENTRIES
16-BIT ENTRIES
2FFFh
2FFFh
Figure 7b. 2-Channel Logging, Equal Resolution
ETL = EHL = 1
ETL = EHL = 1
TLFS = 0; HLFS = 1
TLFS = 1; HLFS = 0
1000h
1000h
TEMPERATURE
2560
8-BIT ENTRIES
TEMPERATURE
2560
19FFh
16-BIT ENTRIES
1A00h
23FFh
HUMIDITY DATA
2560
16-BIT ENTRIES
WITH 16-BIT FORMAT, THE MOST SIGNIFICANT
BYTE IS STORED AT THE LOWER ADDRESS.
2400h
HUMIDITY DATA
2560
8-BIT ENTRIES
2DFFh
2DFFh
2E00h
(NOT USED)
2E00h
(NOT USED)
2FFFh
2FFFh
Figure 7c. 2-Channel Logging, Different Resolution
______________________________________________________________________________________ 27
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
The last step to begin a mission is to issue the Start
Mission command. As soon as it has received this com-
mand, the DS1923 sets the MIP flag and clears the
MEMCLR flag. With the immediate/delayed start mode
(SUTA = 0), after as many minutes as specified by the
Mission Start Delay are over, the device wakes up,
copies the current date and time to the Mission
Timestamp register, and logs the first entry of the mis-
sion. This increments both the Mission Samples
Counter and Device Samples Counter. All subsequent
log entries are made as specified by the value in the
Sample Rate register and the EHSS bit.
at any time, e.g., to watch the progress of a mission.
Attempts to read the passwords read 00h bytes instead
of the data that is stored in the password registers.
Memory Access
Address Registers and Transfer Status
Because of the serial data transfer, the DS1923
employs three address registers called TA1, TA2, and
E/S (Figure 8). Registers TA1 and TA2 must be loaded
with the target address to which the data is written or
from which data is sent to the master upon a Read
command. Register E/S acts like a byte counter and
transfer status register. It is used to verify data integrity
with Write commands. Therefore, the master only has
read access to this register. The lower 5 bits of the E/S
register indicate the address of the last byte that has
been written to the scratchpad. This address is called
ending offset. The DS1923 requires that the ending
offset is always 1Fh for a Copy Scratchpad to func-
tion. Bit 5 of the E/S register, called PF or partial byte
flag, is set if the number of data bits sent by the master
is not an integer multiple of 8. Bit 6 is always a 0. Note
that the lowest 5 bits of the target address also deter-
mine the address within the scratchpad, where interme-
diate storage of data begins. This address is called
byte offset. If the target address for a Write command is
13Ch, for example, the scratchpad stores incoming
data beginning at the byte offset 1Ch and is full after
only 4 bytes. The corresponding ending offset in this
example is 1Fh. For best economy of speed and
DS1923
If the start upon temperature alarm mode is chosen
(SUTA = 1) and temperature logging is enabled (ETL =
1), the DS1923 first waits until the start delay is over.
Then the device wakes up in intervals as specified by
the sample rate and EHSS bit and measures the tem-
perature. This increments the Device Samples Counter
register only. The first sample of the mission is logged
when the temperature alarm occurred. However, the
Mission Sample Counter does not increment. One sam-
ple period later the Mission Timestamp register is set.
From then on, both the Mission Samples Counter and
Device Samples Counter registers increment at the
same time. All subsequent log entries are made as
specified by the value in the Sample Rate register and
the EHSS bit.
The general-purpose memory operates independently of
the other memory sections and is not write protected
during a mission. All the DS1923’s memory can be read
BIT NUMBER
7
6
5
4
3
2
1
0
TARGET ADDRESS (TA1)
T7
T6
T5
T4
T3
T2
T1
T0
TARGET ADDRESS (TA2)
T15
AA
T14
0
T13
PF
T12
E4
T11
E3
T10
E2
T9
E1
T8
E0
ENDING ADDRESS WITH
DATA STATUS (E/S)
(READ ONLY)
Figure 8. Address Registers
28 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
efficiency, the target address for writing should point to
Memory and Control
Function Commands
the beginning of a page, i.e., the byte offset is 0. Thus,
the full 32-byte capacity of the scratchpad is available,
resulting also in the ending offset of 1Fh. The ending
offset together with the PF flag are a means to support
the master checking the data integrity after a Write
command. The highest valued bit of the E/S register,
called authorization accepted (AA), indicates that a
valid Copy command for the scratchpad has been
received and executed. Writing data to the scratchpad
clears this flag.
Figure 9 shows the protocols necessary for accessing
the memory and the special function registers of the
DS1923. An example on how to use these and other
functions to set up the DS1923 for a mission is included
in the Mission Example: Prepare and Start a New
Mission section. The communication between the mas-
ter and the DS1923 takes place either at standard
speed (default, OD = 0) or at overdrive speed (OD =
1). If not explicitly set into the overdrive mode, the
DS1923 assumes standard speed. Internal memory
access during a mission has priority over external
access through the 1-Wire interface. This affects sever-
al commands in this section. See the Memory Access
Conflicts section for details and solutions.
Writing with Verification
To write data to the DS1923, the scratchpad must be
used as intermediate storage. First, the master issues
the Write Scratchpad command to specify the desired
target address, followed by the data to be written to the
scratchpad. In the next step, the master sends the
Read Scratchpad command to read the scratchpad
and to verify data integrity. As preamble to the scratch-
pad data, the DS1923 sends the requested target
address TA1 and TA2 and the contents of the E/S
Register. If the PF flag is set, data did not arrive cor-
rectly in the scratchpad. The master does not need to
continue reading; it can start a new trial to write data to
the scratchpad. Similarly, a set AA flag indicates that
the Write command was not recognized by the device.
If everything went correctly, both flags are cleared and
the ending offset indicates the address of the last byte
written to the scratchpad. Now the master can continue
verifying every data bit. After the master has verified the
data, it must send the Copy Scratchpad command.
This command must be followed exactly by the data of
the three address registers TA1, TA2, and E/S, as the
master has read them verifying the scratchpad. As
soon as the DS1923 has received these bytes, it copies
the data to the requested location beginning at the tar-
get address.
Write Scratchpad [0Fh]
After issuing the Write Scratchpad command, the mas-
ter must first provide the 2-byte target address, fol-
lowed by the data to be written to the scratchpad. The
data is written to the scratchpad starting at the byte off-
set T[4:0]. The master must send as many bytes as are
needed to reach the ending offset of 1Fh. If a data byte
is incomplete, its content is ignored and the partial byte
flag PF is set.
When executing the Write Scratchpad command, the
CRC generator inside the DS1923 calculates a CRC of
the entire data stream, starting at the command code
and ending at the last data byte sent by the master
(Figure 15). This CRC is generated using the CRC-16
polynomial by first clearing the CRC generator and then
shifting in the command code (0Fh) of the Write
Scratchpad command, the target addresses TA1 and
TA2 as supplied by the master, and all the data bytes.
If the ending offset is 11111b, the master can send 16
read time slots and receive the inverted CRC-16 gener-
ated by the DS1923.
Note that both register pages are write protected dur-
ing a mission. Although the Write Scratchpad command
works normally at any time, the subsequent copy
scratchpad to a register page fails during a mission.
______________________________________________________________________________________ 29
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
progress, write attempts to the register pages are not
Read Scratchpad [AAh]
This command is used to verify scratchpad data and
target address. After issuing the Read Scratchpad
command, the master begins reading. The first 2 bytes
are the target address. The next byte is the ending off-
set/data status byte (E/S) followed by the scratchpad
data beginning at the byte offset T[4:0], as shown in
Figure 8. The master can continue reading data until
the end of the scratchpad after which it receives an
inverted CRC-16 of the command code, target
addresses TA1 and TA2, the E/S byte, and the scratch-
pad data starting at the target address. After the CRC
is read, the bus master reads logic 1s from the DS1923
until a reset pulse is issued.
successful. The AA bit remaining at 0 indicates this.
Read Memory with Password
and CRC [69h]
The Read Memory with CRC command is the general
function to read from the device. This command gener-
ates and transmits a 16-bit CRC following the last data
byte of a memory page.
DS1923
After having sent the command code of the Read
Memory with CRC command, the bus master sends a
2-byte address that indicates a starting byte location.
Next, the master must transmit one of the 64-bit pass-
words. If passwords are enabled and the transmitted
password does not match one of the stored passwords,
the Read Memory with Password and CRC command
fails. The device stops communicating and waits for a
reset pulse. If the password was correct or if pass-
words were not enabled, the master reads data from
the DS1923 beginning from the starting address and
continuing until the end of a 32-byte page is reached.
At that point the bus master sends 16 additional read-
data time slots and receives the inverted 16-bit CRC.
With subsequent read-data time slots the master
receives data starting at the beginning of the next
memory page followed again by the CRC for that page.
This sequence continues until the bus master resets the
device. When trying to read the passwords or memory
areas that are marked as “reserved,” the DS1923 trans-
mits 00h or FFh bytes, respectively. The CRC at the end
of a 32-byte memory page is based on the data as it
was transmitted.
Copy Scratchpad with Password [99h]
This command is used to copy data from the scratch-
pad to the writable memory sections. After issuing the
Copy Scratchpad command, the master must provide a
3-byte authorization pattern, which can be obtained by
reading the scratchpad for verification. This pattern
must exactly match the data contained in the three
address registers (TA1, TA2, E/S, in that order). Next,
the master must transmit the 64-bit full access pass-
word. If passwords are enabled and the transmitted
password is different from the stored full access pass-
word, the Copy Scratchpad with Password command
fails. The device stops communicating and waits for a
reset pulse. If the password was correct or if pass-
words were not enabled, the device tests the 3-byte
authorization code. If the authorization code pattern
matches, the AA flag is set and the copy begins. A pat-
tern of alternating 1s and 0s is transmitted after the
data has been copied until the master issues a reset
pulse. While the copy is in progress, any attempt to
reset the part is ignored. Copy typically takes 2μs per
byte.
With the initial pass through the Read Memory with
CRC flow, the 16-bit CRC value is the result of shifting
the command byte into the cleared CRC generator fol-
lowed by the 2 address bytes and the contents of the
data memory. Subsequent passes through the Read
Memory with CRC flow generate a 16-bit CRC that is
the result of clearing the CRC generator and then shift-
ing in the contents of the data memory page. After the
16-bit CRC of the last page is read, the bus master
receives logic 1s from the DS1923 until a reset pulse is
issued. The Read Memory with CRC command
sequence can be ended at any point by issuing a reset
pulse.
The data to be copied is determined by the three
address registers. The scratchpad data from the begin-
ning offset through the ending offset are copied, start-
ing at the target address. The AA flag remains at logic
1 until it is cleared by the next Write Scratchpad com-
mand. With suitable password, the copy scratchpad
always functions for the 16 pages of data memory and
the 2 pages of calibration memory. While a mission is in
30 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
MASTER Tx MEMORY OR
CONTROL FUNCTION COMMAND
FROM ROM FUNCTIONS
FLOWCHART (FIGURE 11)
99h
TO FIGURE 9b
0Fh
AAh
N
N
N
COPY SCRATCHPAD
[WITH PW]
WRITE SCRATCHPAD?
READ SCRATCHPAD?
Y
Y
Y
MASTER Tx
TA1 [T7:T0]
MASTER Rx
TA1 [T7:T0]
MASTER Tx
TA1 [T7:T0], TA2 [T15:T8]
AUTHORIZATION
CODE
MASTER Tx
TA2 [T15:T8]
MASTER Rx
TA2 [T15:T8]
MASTER Tx
E/S BYTE
DS1923 SETS
SCRATCHPAD OFFSET = [T4:T0]
AND CLEARS (PF, AA)
MASTER Rx ENDING OFFSET
WITH DATA STATUS
(E/S)
MASTER Tx
64 BITS [PASSWORD]
N
N
PASSWORD
ACCEPTED?
MASTER Tx DATA BYTE
TO SCRATCHPAD OFFSET
DS1923 SETS
SCRATCHPAD OFFSET = [T4:T0]
Y
DS1923
INCREMENTS
SCRATCHPAD
OFFSET
DS1923 SETS [E4:E0] =
SCRATCHPAD OFFSET
DS1923
INCREMENTS
SCRATCHPAD
OFFSET
MASTER Rx DATA BYTE FROM
SCRATCHPAD OFFSET
AUTHORIZATION
CODE MATCH?
Y
Y
Y
MASTER Tx RESET?
N
MASTER Tx RESET?
N
AA = 1
DS1923 COPIES SCRATCHPAD
DATA TO MEMORY
N
Y
SCRATCHPAD
OFFSET = 11111b?
N
SCRATCHPAD
OFFSET = 11111b?
PARTIAL
BYTE WRITTEN?
Y
Y
Y
MASTER Rx "1"s
MASTER Rx "1"s
N
COPYING
FINISHED
MASTER Rx CRC-16 OF
COMMAND, ADDRESS DATA,
E/S BYTE, AND DATA STARTING
AT THE TARGET ADDRESS
N
MASTER Tx RESET?
N
N
Y
MASTER Tx RESET?
Y
PF = 1
DS1923 Tx "0"
MASTER Rx CRC-16 OF
COMMAND, ADDRESS DATA
Y
MASTER Tx RESET?
Y
MASTER Tx RESET?
N
Y
MASTER Tx RESET?
MASTER Rx "1"s
N
N
DS1923 Tx "1"
MASTER Rx "1"s
N
MASTER Tx RESET?
Y
FROM FIGURE 9b
TO ROM FUNCTIONS
FLOWCHART (FIGURE 11)
Figure 9a. Memory/Control Function Flowchart
______________________________________________________________________________________ 31
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
69h
96h
FROM FIGURE 9a
TO FIGURE 9c
55h
N
N
N
READ MEMORY [WITH
PW] AND CRC
CLEAR MEMORY
[WITH PW]
FORCED CONVERSION?
Y
Y
Y
DS1923
MASTER Tx
MASTER Tx
MASTER Tx
TA1 [T7:T0], TA2 [T15:T8]
64 BITS [PASSWORD]
FFh DUMMY BYTE
MASTER Tx
64 BITS [PASSWORD]
MASTER Tx
FFh DUMMY BYTE
Y
MISSION IN
PROGRESS?
DECISION MADE
BY DS1923
N
N
N
Y
PASSWORD
ACCEPTED?
PASSWORD
ACCEPTED?
DS1923 PERFORMS A
TEMPERATURE CONVERSION
Y
Y
DECISION MADE
BY MASTER
DS1923 SETS
MEMORY ADDRESS = [T15:T0]
DS1923 COPIES RESULT TO
ADDRESS 020C/Dh
MISSION IN
PROGRESS?
N
MASTER Rx DATA BYTE FROM
MEMORY ADDRESS
DS1923 PERFORMS A
HUMIDITY CONVERSION
DS1923 CLEARS
MISSION TIMESTAMP,
MISSION SAMPLES COUNTER,
ALARM FLAGS
DS1923
INCREMENTS
ADDRESS
DS1923 COPIES RESULT TO
ADDRESS 020E/Fh
Y
MASTER Tx RESET?
N
COUNTER
DS1923 SETS
MEMCLR = 1
N
MASTER Tx RESET?
Y
N
END OF PAGE?
Y
N
MASTER Tx RESET?
Y
MASTER Rx CRC-16 OF
COMMAND, ADDRESS, DATA
(1ST PASS); CRC-16 OF DATA
(SUBSEQUENT PASSES)
N
MASTER Tx RESET
CRC OK?
Y
N
N
END OF MEMORY?
Y
MASTER Rx "1"s
MASTER Tx RESET?
Y
TO FIGURE 9a
FROM FIGURE 9c
Figure 9b. Memory/Control Function Flowchart (continued)
32 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
CCh
START MISSION
[WITH PW]
33h
FROM FIGURE 9b
N
N
STOP MISSION
[WITH PW]
MISSION START
DELAY PROCESS
Y
Y
MASTER Tx
MASTER Tx
64 BITS [PASSWORD]
64 BITS [PASSWORD]
Y
START DELAY
COUNTER = 0?
MASTER Tx
FFh DUMMY BYTE
MASTER Tx
FFh DUMMY BYTE
N
DS1923 WAITS FOR 1 MINUTE
N
Y
N
N
N
PASSWORD
ACCEPTED?
PASSWORD
ACCEPTED?
DS1923 DECREMENTS
START DELAY COUNTER
Y
Y
N
MISSION IN
PROGRESS?
MISSION IN
PROGRESS?
SUTA = 1?
Y
N
Y
DS1923 SETS WFTA = 1
DS1923 SETS
MIP = 0,
WFTA = 0
MEMCLR = 1?
Y
DS1923 WAITS ONE
SAMPLE PERIOD
DS1923 SETS
MIP = 1,
MEMCLR = 0
N
Y
MASTER Tx RESET?
Y
MIP = 0?
N
DS1923 INITIATES MISSION
START DELAY PROCESS
DS1923 PERFORMS 8-BIT
TEMPERATURE CONVERSION
N
N
TEMPERATURE
ALARM?
MASTER Tx RESET?
Y
Y
THE MISSION
DS1923 SETS WFTA = 0
AND LOGS FIRST SAMPLE
SAMPLES COUNTER
DOES NOT
INCREMENT
DS1923 WAITS ONE
SAMPLE PERIOD
IF SUTA = 1,
THIS IS THE
SECOND SAMPLE.
DS1923 COPIES RTC DATA TO
MISSION TIMESTAMP REGISTER
DS1923 STARTS LOGGING
TAKING FIRST SAMPLE
END OF PROCESS
TO FIGURE 9b
Figure 9c. Memory/Control Function Flowchart (continued)
______________________________________________________________________________________ 33
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Clear Memory with Password [96h]
The Clear Memory with Password command is used to
prepare the device for another mission. This command
is only executed if no mission is in progress. After the
command code, the master must transmit the 64-bit
full-access password followed by an FFh dummy byte.
If passwords are enabled and the transmitted pass-
word is different from the stored full access password
or a mission is in progress, the Clear Memory with
Password command fails. The device stops communi-
cating and waits for a reset pulse. If the password was
correct or if passwords were not enabled, the device
clears the Mission Timestamp register, Mission
Samples Counter register, and all alarm flags of the
Alarm Status register. After these cells are cleared, the
MEMCLR bit of the General Status register reads 1 to
indicate the successful execution of the Clear Memory
with Password command. Clearing of the data-log
memory is not necessary because the Mission Samples
Counter indicates how many entries in the data-log
memory are valid.
Start Mission with Password [CCh]
The DS1923 uses a control function command to start a
mission. A new mission can only be started if the previ-
ous mission has been ended and the memory has been
cleared. After the command code, the master must
transmit the 64-bit full access password followed by an
FFh dummy byte. If passwords are enabled and the
transmitted password is different from the stored full-
access password or a mission is in progress, the Start
Mission with Password command fails. The device
stops communicating and waits for a reset pulse. If the
password was correct or if passwords were not
enabled, the device starts a mission. If SUTA = 0, the
sampling begins as soon as the Mission Start Delay is
over. If SUTA = 1, the first sample is written to the data-
log memory at the time the temperature alarm
occurred. However, the Mission Sample Counter does
not increment. One sample period later, the Mission
Timestamp register is set and the regular sampling and
logging begins. While the device is waiting for a tem-
perature alarm to occur, the WFTA flag in the General
Status register reads 1. During a mission there is only
read access to the register pages.
DS1923
Forced Conversion [55h]
The Forced Conversion command can be used to mea-
sure the temperature and humidity without starting a
mission. After the command code, the master must
send one FFh byte to get the conversion started. The
conversion result is found as a 16-bit value in the Latest
Temperature Conversion Result and Latest Humidity
Conversion Result registers. This command is only exe-
cuted if no mission is in progress (MIP = 0). It cannot
be interrupted and takes maximum 666ms to complete.
During this time memory access through the 1-Wire
interface is blocked. The device behaves the same way
as during a mission when the sampling interferes with a
memory/control function command. See the Memory
Access Conflicts section for details.
Stop Mission with Password [33h]
The DS1923 uses a control function command to stop a
mission. Only a mission that is in progress can be
stopped. After the command code, the master must
transmit the 64-bit full access password followed by a
FFh dummy byte. If passwords are enabled and the
transmitted password is different from the stored full-
access password or a mission is not in progress, the
Stop Mission with Password command fails. The device
stops communicating and waits for a reset pulse. If the
password was correct or if passwords were not
enabled, the device clears the MIP bit in the General
Status register and restores write access to the register
pages. The WFTA bit is not cleared. See the description
of the general status register for a method to clear the
WFTA bit.
34 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
device is waiting for a temperature alarm. Table 5
Memory Access Conflicts
explains how the remaining five commands are affect-
While a mission is in progress or while the device is
ed by internal activity, how to detect this interference,
and how to work around it.
waiting for a temperature alarm to start a mission, peri-
odically a temperature and/or humidity sample is taken
and logged. This “internal activity” has priority over
1-Wire communication. As a consequence, device-spe-
cific commands (excluding ROM function commands
and 1-Wire reset) do not perform properly when internal
and “external” activities interfere with each other. Not
affected are the commands Start Mission, Forced
Conversion, and Clear Memory, because they are not
applicable while a mission is in progress or while the
The interference is more likely to be seen with a high-
sample rate (one sample every second) and with high-
resolution logging, which can last up to 666ms when
both temperature and humidity are recorded. With
lower sample rates, interference may hardly be visible
at all. In any case, when writing driver software it is
important to know about the possibility of interference
and to take measures to work around it.
Table 5. Memory Access Conflicts and Solutions
COMMAND
INDICATION OF INTERFERENCE
SOLUTION
Wait 0.5s, 1-Wire reset, address the device, repeat
Write Scratchpad with the same data, and check the
validity of the CRC-16 at the end of the command
flow. Alternatively, use Read Scratchpad to verify
data integrity.
The CRC-16 at the end of the command flow reads
FFFFh.
Write Scratchpad
The data read changes to FFh bytes or all bytes
received are FFh, including the CRC at the end of
the command flow.
Wait 0.5s, 1-Wire reset, address the device, repeat
Read Scratchpad, and check the validity of the
CRC-16 at the end of the command flow.
Read Scratchpad
Copy Scratchpad
Wait 0.5s, 1-Wire reset, address the device, issue
Read Scratchpad, and check the AA bit of the E/S
byte. If the AA bit is set, Copy Scratchpad was
successful.
The device behaves as if the authorization code or
password was not valid or as if the copy function
would not end.
The data read changes to all FFh bytes or all bytes
received are FFh, including the CRC at the end of
the command flow, despite a valid password.
Wait 0.5s, 1-Wire reset, address the device, repeat
Read Memory with CRC, and check the validity of
the CRC-16 at the end of the memory page.
Read Memory with
CRC
Wait 0.5s, 1-Wire reset, address the device, and
repeat Stop Mission. Perform a 1-Wire reset, address
the device, read the General Status register at
address 0215h, and check the MIP bit. If the MIP bit
is 0, Stop Mission was successful.
The General Status register at address 0215h reads
FFh or the MIP bit is 1 while bits 0, 2, and 5 are 0.
Stop Mission
______________________________________________________________________________________ 35
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
The value of the pullup resistor primarily depends on
1-Wire Bus System
the network size and load conditions. The DS1923
requires a pullup resistor of maximum 2.2kΩ at any
speed.
The 1-Wire bus is a system that has a single bus mas-
ter and one or more slaves. In all instances the DS1923
is a slave device. The bus master is typically a micro-
controller. The discussion of this bus system is broken
down into three topics: hardware configuration, trans-
action sequence, and 1-Wire signaling (signal types
and timing). The 1-Wire protocol defines bus transac-
tions in terms of the bus state during specific time slots
that are initiated on the falling edge of sync pulses from
the bus master.
The idle state for the 1-Wire bus is high. If for any rea-
son a transaction needs to be suspended, the bus
must be left in the idle state if the transaction is to
resume. If this does not occur and the bus is left low for
more than 16μs (overdrive speed) or more than 120μs
(standard speed), one or more devices on the bus may
be reset. Note that the DS1923 does not quite meet the
full 16μs maximum low time of the normal 1-Wire bus
overdrive timing. With the DS1923 the bus must be left
low for no longer than 12μs at overdrive to ensure that
no DS1923 on the 1-Wire bus performs a reset. The
DS1923 communicates properly when used in conjunc-
tion with a DS2480B or DS2490 1-Wire driver and
adapters that are based on these driver chips.
DS1923
Hardware Configuration
The 1-Wire bus has only a single line by definition; it is
important that each device on the bus be able to drive
it at the appropriate time. To facilitate this, each device
attached to the 1-Wire bus must have open-drain or
three-state outputs. The 1-Wire port of the DS1923 is
open drain with an internal circuit equivalent to that
shown in Figure 10.
Transaction Sequence
The protocol for accessing the DS1923 through the
1-Wire port is as follows:
A multidrop bus consists of a 1-Wire bus with multiple
slaves attached. At standard speed the 1-Wire bus has
a maximum data rate of 16.3kbps. The speed can be
boosted to 142kbps by activating the overdrive mode.
The DS1923 is not guaranteed to be fully compliant to
the iButton standard. Its maximum data rate in standard
speed is 15.4kbps and 125kbps in overdrive speed.
• Initialization
• ROM Function Command
• Memory/Control Function Command
• Transaction/Data
V
PUP
BUS MASTER
DS1923 1-Wire PORT
R
PUP
DATA
Rx
Tx
Rx
I
L
Tx
Rx = RECEIVE
Tx = TRANSMIT
OPEN-DRAIN
PORT PIN
100Ω MOSFET
Figure 10. Hardware Configuration
36 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
numbers of all slave devices. For each bit of the regis-
tration number, starting with the least significant bit, the
Initialization
All transactions on the 1-Wire bus begin with an initial-
bus master issues a triplet of time slots. On the first slot,
each slave device participating in the search outputs
the true value of its registration number bit. On the sec-
ond slot, each slave device participating in the search
outputs the complemented value of its registration num-
ber bit. On the third slot, the master writes the true
value of the bit to be selected. All slave devices that do
not match the bit written by the master stop participat-
ing in the search. If both of the read bits are zero, the
master knows that slave devices exist with both states
of the bit. By choosing which state to write, the bus
master branches in the ROM code tree. After one com-
plete pass, the bus master knows the registration num-
ber of a single device. Additional passes identify the
registration numbers of the remaining devices. Refer to
Application Note 187: 1-Wire Search Algorithm for a
detailed discussion, including an example.
ization sequence. The initialization sequence consists
of a reset pulse transmitted by the bus master followed
by presence pulse(s) transmitted by the slave(s). The
presence pulse lets the bus master know that the
DS1923 is on the bus and is ready to operate. For more
details, see the 1-Wire Signaling section.
1-Wire ROM Function Commands
Once the bus master has detected a presence, it can
issue one of the eight ROM function commands that the
DS1923 supports. All ROM function commands are 8
bits long. A list of these commands follows (see the
flowchart in Figure 11).
Read ROM [33h]
This command allows the bus master to read the
DS1923’s 8-bit family code, unique 48-bit serial number,
and 8-bit CRC. This command can only be used if there
is a single slave on the bus. If more than one slave is pre-
sent on the bus, a data collision occurs when all slaves
try to transmit at the same time (open drain produces a
wired-AND result). The resultant family code and 48-bit
serial number results in a mismatch of the CRC.
Conditional Search ROM [ECh]
The Conditional Search ROM command operates simi-
larly to the Search ROM command except that only
those devices that fulfill certain conditions participate in
the search. This function provides an efficient means
for the bus master to identify devices on a multidrop
system that have to signal an important event. After
each pass of the conditional search that successfully
determined the 64-bit ROM code for a specific device
on the multidrop bus, that particular device can be indi-
vidually accessed as if a Match ROM had been issued,
since all other devices have dropped out of the search
process and are waiting for a reset pulse.
Match ROM [55h]
The Match ROM command, followed by a 64-bit ROM
sequence, allows the bus master to address a specific
DS1923 on a multidrop bus. Only the DS1923 that exact-
ly matches the 64-bit ROM sequence responds to the fol-
lowing memory function command. All other slaves wait
for a reset pulse. This command can be used with a sin-
gle device or multiple devices on the bus.
The DS1923 responds to the conditional search ROM
command if one of the five alarm flags of the Alarm
Status register (address 0214h) reads 1. The humidity
and temperature alarm only occurs if enabled (see the
Temperature Sensor Alarm and Humidity Alarm sec-
tions). The BOR alarm is always enabled. The first
alarm that occurs makes the device respond to the
Conditional Search ROM command.
Search ROM [F0h]
When a system is initially brought up, the bus master
might not know the number of devices on the 1-Wire
bus or their registration numbers. By taking advantage
of the wired-AND property of the bus, the master can
use a process of elimination to identify the registration
______________________________________________________________________________________ 37
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
ROM command sets the DS1923 in the overdrive mode
Skip ROM [CCh]
This command can save time in a single-drop bus sys-
tem by allowing the bus master to access the memory
functions without providing the 64-bit ROM code. For
example, if more than one slave is present on the bus
and a Read command is issued following the Skip ROM
command, data collision occurs on the bus as multiple
slaves transmit simultaneously (open-drain pulldowns
produce a wired-AND result).
(OD = 1). All communication following this command
must occur at overdrive speed until a reset pulse of
minimum 690μs duration resets all devices on the bus
to standard speed (OD = 0).
When issued on a multidrop bus, this command sets all
overdrive-supporting devices into overdrive mode. To
subsequently address a specific overdrive-supporting
device, a reset pulse at overdrive speed must be
issued followed by a Match ROM or Search ROM com-
mand sequence. This speeds up the time for the
search process. If more than one slave supporting
overdrive is present on the bus and the Overdrive-Skip
ROM command is followed by a Read command, data
collision occurs on the bus as multiple slaves transmit
simultaneously (open-drain pulldowns produce a wired-
AND result).
DS1923
Resume [A5h]
The DS1923 must be accessed several times before a
mission starts. In a multidrop environment this means
that the 64-bit ROM code after a Match ROM command
must be repeated for every access. To maximize the
data throughput in a multidrop environment, the Resume
command was implemented. This command checks the
status of the RC bit and, if it is set, directly transfers con-
trol to the memory/control functions, similar to a Skip
ROM command. The only way to set the RC bit is
through successfully executing the Match ROM, Search
ROM, or Overdrive-Match ROM command. Once the RC
bit is set, the device can repeatedly be accessed
through the Resume command. Accessing another
device on the bus clears the RC bit, preventing two or
more devices from simultaneously responding to the
Resume command.
Overdrive-Match ROM [69h]
The Overdrive-Match ROM command followed by a
64-bit ROM sequence transmitted at overdrive speed
allows the bus master to address a specific DS1923 on
a multidrop bus and to simultaneously set it in overdrive
mode. Only the DS1923 that exactly matches the 64-bit
ROM sequence responds to the subsequent
memory/control function command. Slaves already in
overdrive mode from a previous Overdrive-Skip ROM or
successful Overdrive-Match ROM command remain in
overdrive mode. All overdrive-capable slaves return to
standard speed at the next reset pulse of minimum
690μs duration. The Overdrive-Match ROM command
can be used with a single or multiple devices on the
bus.
Overdrive-Skip ROM [3Ch]
On a single-drop bus this command can save time by
allowing the bus master to access the memory/control
functions without providing the 64-bit ROM code. Unlike
the normal Skip ROM command, the Overdrive-Skip
38 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
BUS MASTER Tx
RESET PULSE
FROM FIGURE 11b
FROM MEMORY/CONTROL
FUNCTION FLOWCHART (FIGURE 9)
OD
N
OD = 0
RESET PULSE?
Y
BUS MASTER Tx ROM
FUNCTION COMMAND
DS1923 Tx
PRESENCE PULSE
33h
READ ROM
COMMAND?
55h
MATCH ROM
COMMAND?
F0h
SEARCH ROM
COMMAND?
ECh
TO FIGURE 11b
N
N
N
N
CONDITIONAL SEARCH
COMMAND?
Y
Y
Y
Y
RC = 0
RC = 0
RC = 0
RC = 0
N
N
N
CONDITION
MET?
Y
DS1923 Tx BIT 0
DS1923 Tx BIT 0
MASTER Tx BIT 0
DS1923 Tx BIT 0
DS1923 Tx BIT 0
MASTER Tx BIT 0
DS1923 Tx
FAMILY CODE
(1 BYTE)
MASTER Tx BIT 0
BIT 0 MATCH?
N
N
BIT 0 MATCH?
Y
BIT 0 MATCH?
Y
Y
DS1923 Tx BIT 1
DS1923 Tx BIT 1
MASTER Tx BIT 1
DS1923 Tx BIT 1
DS1923 Tx BIT 1
MASTER Tx BIT 1
DS1923 Tx
SERIAL NUMBER
(6 BYTES)
MASTER Tx BIT 1
N
N
BIT 1 MATCH?
Y
BIT 1 MATCH?
Y
BIT 1 MATCH?
Y
DS1923 Tx BIT 63
DS1923 Tx BIT 63
MASTER Tx BIT 63
DS1923 Tx BIT 63
DS1923 Tx BIT 63
MASTER Tx BIT 63
DS1923 Tx
CRC BYTE
MASTER Tx BIT 63
BIT 63 MATCH?
N
N
N
BIT 63 MATCH?
BIT 63 MATCH?
Y
Y
Y
RC = 1
RC = 1
RC = 1
TO FIGURE 11b
FROM FIGURE 11b
TO MEMORY/CONTROL
FUNCTION FLOWCHART (FIGURE 9)
Figure 11a. ROM Functions Flowchart
______________________________________________________________________________________ 39
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
TO FIGURE 11a
DS1923
CCh
SKIP ROM
COMMAND?
A5h
RESUME
COMMAND?
3Ch
OVERDRIVE-
SKIP ROM?
69h
OVERDRIVE-
MATCH ROM?
FROM FIGURE 11a
N
N
N
N
Y
Y
Y
Y
RC = 0
RC = 0; OD = 1
RC = 0; OD = 1
N
RC = 1?
Y
Y
MASTER Tx
RESET?
MASTER Tx BIT 0
BIT 0 MATCH?
N
(SEE NOTE)
OD = 0
Y
N
N
N
MASTER Tx
RESET?
N
Y
MASTER Tx BIT 1
(SEE NOTE)
OD = 0
BIT 1 MATCH?
Y
MASTER Tx BIT 63
BIT 63 MATCH?
(SEE NOTE)
OD = 0
Y
RC = 1
FROM FIGURE 11a
TO FIGURE 11a
NOTE: THE OD FLAG REMAINS AT 1 IF THE DEVICE WAS ALREADY AT OVERDRIVE SPEED BEFORE THE OVERDRIVE-MATCH ROM COMMAND WAS ISSUED.
Figure 11b. ROM Functions Flowchart (continued)
40 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
DS1923 is in overdrive mode and t
is no longer
RSTL
1-Wire Signaling
than 80μs, the device remains in overdrive mode.
The DS1923 requires strict protocols to ensure data
integrity. The protocol consists of four types of signaling
on one line: reset sequence with reset pulse and pres-
ence pulse, write-zero, write-one, and read-data. Except
for the presence pulse, the bus master initiates all these
signals. The DS1923 can communicate at two different
speeds: standard speed and overdrive speed. If not
explicitly set into the overdrive mode, the DS1923 com-
municates at standard speed. While in overdrive mode
the fast timing applies to all waveforms.
After the bus master has released the line, it goes into
receive mode (Rx). Now the 1-Wire bus is pulled to
PUP
V
through the pullup resistor or, in the case of a
DS2480B driver, through active circuitry. When the
threshold V is crossed, the DS1923 waits for t
TH
PDH
and then transmits a presence pulse by pulling the line
low for t . To detect a presence pulse, the master
PDL
must test the logical state of the 1-Wire line at t
.
MSP
The t
window must be at least the sum of
RSTH
t
t
, t
, and t
. Immediately after
RECMIN
PDHMAX PDLMAX
RSTH
To get from idle to active, the voltage on the 1-Wire line
is expired, the DS1923 is ready for data commu-
needs to fall from V
below the threshold V . To get
TL
PUP
nication. In a mixed population network, t
should
RSTH
from active to idle, the voltage needs to rise from
past the threshold V . The time it takes for the
be extended to minimum 480μs at standard speed and
48μs at overdrive speed to accommodate other 1-Wire
devices.
V
ILMAX
TH
voltage to make this rise is seen in Figure 12 as “ε” and
its duration depends on the pullup resistor (R ) used
PUP
and the capacitance of the 1-Wire network attached.
Read/Write Time Slots
Data communication with the DS1923 takes place in
time slots that carry a single bit each. Write time slots
transport data from bus master to slave. Read time slots
transfer data from slave to master. The definitions of the
write and read time slots are illustrated in Figure 13.
The voltage V
is relevant for the DS1923 when
ILMAX
determining a logical level, not triggering any events.
The initialization sequence required to begin any com-
munication with the DS1923 is shown in Figure 12. A
reset pulse followed by a presence pulse indicates the
DS1923 is ready to receive data, given the correct ROM
and memory function command. If the bus master uses
slew-rate control on the falling edge, it must pull down
All communication begins with the master pulling the
data line low. As the voltage on the 1-Wire line falls
below the threshold V , the DS1923 starts its internal
TL
timing generator that determines when the data line is
sampled during a write time slot and how long data is
valid during a read time slot.
the line for t
RSTL
+ t to compensate for the edge. A
F
RSTL
t
duration of 690μs or longer exits the overdrive
mode, returning the device to standard speed. If the
MASTER Tx "RESET PULSE"
MASTER Rx "PRESENCE PULSE"
ε
t
MSP
V
PUP
V
IHMASTER
V
TH
V
TL
V
ILMAX
0V
t
PDH
t
t
t
REC
RSTL
PDL
t
F
t
RSTH
RESISTOR
MASTER
DS1923
Figure 12. Initialization Procedure: Reset and Presence Pulse
______________________________________________________________________________________ 41
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Master-to-Slave
sources can also result in signal glitching. A glitch dur-
For a write-one time slot, the voltage on the data line
ing the rising edge of a time slot can cause a slave
device to lose synchronization with the master and, as
a consequence, result in a search ROM command
coming to a dead end or cause a device-specific func-
tion command to abort. For better performance in net-
work applications, the DS1923 uses a new 1-Wire
front-end, which makes it less sensitive to noise and
also reduces the magnitude of noise injected by the
slave device itself.
must have crossed the V threshold before the write-one
TH
low time t
is expired. For a write-zero time slot,
W1LMAX
the voltage on the data line must stay below the V
TH
threshold until the write-zero low time t
is expired.
W0LMIN
The voltage on the data line should not exceed V
ILMAX
window. After the V
DS1923
during the entire t
or t
W0L
W1L TH
threshold has been crossed, the DS1923 needs a recov-
ery time t before it is ready for the next time slot.
REC
The DS1923’s 1-Wire front-end differs from traditional
slave devices in four characteristics:
Slave-to-Master
A read-data time slot begins like a write-one time slot.
1) The falling edge of the presence pulse has a con-
trolled slew rate. This provides a better match to the
line impedance than a digitally switched transistor,
converting the high-frequency ringing known from
traditional devices into a smoother, low-bandwidth
transition. The slew-rate control is specified by the
The voltage on the data line must remain below V
TL
RL
until the read low time t
is expired. During the t
RL
window, when responding with a 0, the DS1923 starts
pulling the data line low; its internal timing generator
determines when this pulldown ends and the voltage
starts rising again. When responding with a 1, the
DS1923 does not hold the data line low at all, and the
parameter t
, which has different values for stan-
FPD
dard and overdrive speed.
voltage starts rising as soon as t is over.
RL
2) There is additional lowpass filtering in the circuit that
detects the falling edge at the beginning of a time
slot. This reduces the sensitivity to high-frequency
noise. This additional filtering does not apply at over-
drive speed.
The sum of t + δ (rise time) on one side and the inter-
RL
nal timing generator of the DS1923 on the other side
define the master sampling window (t
MSRMAX
the data line. For most reliable communication, t
to
MSRMIN
t
) in which the master must perform a read from
RL
should be as short as permissible and the master
should read close to but no later than t . After
3) There is a hysteresis at the low-to-high switching
MSRMAX
threshold V . If a negative glitch crosses V
but
TH
TH
reading from the data line, the master must wait until
does not go below V
- V , it is not recognized
HY
TH
t
is expired. This guarantees sufficient recovery
REC
SLOT
(Figure 14, Case A). The hysteresis is effective at
any 1-Wire speed.
time t
slot.
for the DS1923 to get ready for the next time
4) There is a time window specified by the rising edge
hold-off time t
during which glitches are ignored,
Improved Network Behavior
(Switchpoint Hysteresis)
REH
even if they extend below V
- V
threshold
HY
TH
REH
(Figure 14, Case B, t
< t
). Deep voltage
GL
In a 1-Wire environment, line termination is possible
only during transients controlled by the bus master (1-
Wire driver). 1-Wire networks, therefore, are susceptible
to noise of various origins. Depending on the physical
size and topology of the network, reflections from end
points and branch points can add up or cancel each
other to some extent. Such reflections are visible as
glitches or ringing on the 1-Wire communication line.
Noise coupled onto the 1-Wire line from external
droops or glitches that appear late after crossing the
threshold and extend beyond the t window
V
TH
REH
cannot be filtered out and are taken as the begin-
ning of a new time slot (Figure 14, Case C, t
≥
GL
t ).
REH
Devices that have the parameters t , V , and t
FPD HY REH
specified in their electrical characteristics use the
improved 1-Wire front-end.
42 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
WRITE-ONE TIME SLOT
t
W1L
V
PUP
V
IHMASTER
V
TH
V
TL
V
ILMAX
0V
ε
t
F
t
SLOT
RESISTOR
MASTER
WRITE-ZERO TIME SLOT
t
W0L
V
PUP
V
IHMASTER
V
TH
V
TL
V
ILMAX
0V
ε
t
F
t
REC
t
SLOT
RESISTOR
MASTER
READ-DATA TIME SLOT
t
MSR
t
RL
V
PUP
V
IHMASTER
V
TH
MASTER
SAMPLING
WINDOW
V
TL
V
ILMAX
0V
δ
t
t
REC
F
t
SLOT
RESISTOR
MASTER
DS1923
Figure 13. Read/Write Timing Diagrams
______________________________________________________________________________________ 43
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
t
REH
t
REH
V
PUP
V
TH
V
HY
CASE A
CASE B
CASE C
DS1923
0V
t
GL
t
GL
Figure 14. Noise Suppression Scheme
16
15
2
POLYNOMIAL = X + X + X + 1
1ST
2ND
3RD
4TH
5TH
6TH
7TH
8TH
STAGE
STAGE
STAGE
STAGE
STAGE
STAGE
STAGE
STAGE
0
1
2
3
4
5
6
7
X
X
X
X
X
X
X
X
9TH
STAGE
10TH
STAGE
11TH
STAGE
12TH
STAGE
13TH
STAGE
14TH
STAGE
15TH
STAGE
16TH
STAGE
8
9
10
11
12
13
14
15
16
CRC OUTPUT
X
X
X
X
X
X
X
X
X
INPUT DATA
Figure 15. CRC-16 Hardware Description and Polynomial
CRC, the 16-bit CRC is always communicated in the
inverted form. A CRC generator inside the DS1923
(Figure 15) calculates a new 16-bit CRC as shown in
the command flowchart of Figure 9. The bus master
compares the CRC value read from the device to the
one it calculates from the data and decides whether to
continue with an operation or to reread the portion of
the data with the CRC error. With the initial pass
through the Read Memory with CRC flowchart, the 16-
bit CRC value is the result of shifting the command byte
into the cleared CRC generator, followed by the 2
address bytes and the data bytes. The password is
excluded from the CRC calculation. Subsequent pass-
es through the Read Memory with CRC flowchart gen-
erate a 16-bit CRC that is the result of clearing the CRC
generator and then shifting in the data bytes.
CRC Generation
The DS1923 uses two types of CRCs. One CRC is an
8-bit type and is stored in the most significant byte of
the 64-bit ROM. The bus master can compute a CRC
value from the first 56 bits of the 64-bit ROM and com-
pare it to the value stored within the DS1923 to deter-
mine if the ROM data has been received error-free. The
equivalent polynomial function of this CRC is
8
5
4
X + X + X + 1. This 8-bit CRC is received in the true
(noninverted) form, and it is computed at the factory
and lasered into the ROM.
The other CRC is a 16-bit type, generated according to
the standardized CRC-16 polynomial function
16
15
2
X
+ X + X + 1. This CRC is used for error detec-
tion when reading register pages or the data-log mem-
ory using the Read Memory with CRC command and
for fast verification of a data transfer when writing to or
reading from the scratchpad. In contrast to the 8-bit
With the Write Scratchpad command, the CRC is gener-
ated by first clearing the CRC generator and then shift-
44 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
ing in the command code, the target addresses TA1
shifting in the command code, the target addresses
TA1 and TA2, the E/S byte, and the scratchpad data
starting at the target address. The DS1923 transmits
this CRC only if the reading continues through the end
of the scratchpad, regardless of the actual ending off-
set. For more information on generating CRC values,
refer to Application Note 27.
and TA2, and all the data bytes. The DS1923 transmits
this CRC only if the data bytes written to the scratchpad
include scratchpad ending offset 11111b. The data can
start at any location within the scratchpad.
With the Read Scratchpad command, the CRC is gen-
erated by first clearing the CRC generator and then
Command-Specific 1-Wire Communication Protocol—Legend
SYMBOL
RST
DESCRIPTION
1-Wire reset pulse generated by master.
PD
1-Wire presence pulse generated by slave.
Command and data to satisfy the ROM function protocol.
Command “Write Scratchpad.”
Select
WS
RS
Command “Read Scratchpad.”
CPS
Command “Copy Scratchpad with Password.”
Command “Read Memory with Password and CRC.”
Command “Clear Memory with Password.”
RMC
CM
FC
Command “Forced Conversion.”
SM
Command “Start Mission with Password.”
STP
Command “Stop Mission with Password.”
TA
Target Address TA1, TA2.
TA–E/S
<Data to EOS>
<Data to EOP>
<Data to EOM>
<PW/Dummy>
<32 Bytes>
<Data>
FFh
Target Address TA1, TA2 with E/S byte.
Transfer of as many data bytes as are needed to reach the scratchpad offset 1Fh.
Transfer of as many data bytes as are needed to reach the end of a memory page.
Transfer as many bytes as are needed to reach the end of the data-log memory.
Transfer of 8 bytes that either represent a valid password or acceptable dummy data.
Transfer of 32 bytes.
Transfer of an undetermined amount of data.
Transmission of one FFh byte.
CRC-16
FF Loop
AA Loop
Transfer of an inverted CRC-16.
Indefinite loop where the master reads FF bytes.
Indefinite loop where the master reads AA bytes.
______________________________________________________________________________________ 45
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Command-Specific 1-Wire Communication Protocol—Color Codes
Master-to-Slave Slave-to-Master
1-Wire Communication Examples
DS1923
Write Scratchpad, Reaching the End of the Scratchpad (Cannot Fail)
RST PD Select WS TA <Data to EOS> CRC-16 FF Loop
Read Scratchpad (Cannot Fail)
RST PD Select RS TA-E/S <Data to EOS> CRC-16 FF Loop
Copy Scratchpad with Password (Success)
RST PD Select CPS TA-E/S <PW/Dummy> AA Loop
Copy Scratchpad with Password (Fail TA-E/S or Password)
RST PD Select CPS TA-E/S <PW/Dummy> FF Loop
Read Memory with Password and CRC (Success)
RST PD Select RMC TA <PW/Dummy> <Data to EOP> CRC-16
<32 Bytes>
CRC-16 FF Loop
Loop
Read Memory with Password and CRC (Fail Password or Address)
RST PD Select RMC TA <PW/Dummy> FF Loop
Clear Memory with Password
RST PD Select CM <PW/Dummy> FFh FF Loop
To verify success, read the General Status register at address 0215h. If MEMCLR is 1, the command was
executed successfully.
46 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
1-Wire Communication Examples (continued)
Forced Conversion
RST PD Select FC FFh FF Loop
To read the result and to verify success, read the addresses 020Ch to 020Fh (results) and the Device Samples
Counter at address 0223h to 0225h. If the count has incremented, the command was executed successfully.
Start Mission with Password
RST PD Select SM <PW/Dummy> FFh FF Loop
To verify success, read the General Status register at address 0215h. If MIP is 1 and MEMCLR is 0, the command
was executed successfully.
Stop Mission with Password
RST PD Select STP <PW/Dummy> FFh FF Loop
To verify success, read the General Status register at address 0215h. If MIP is 0, the command was executed
successfully.
Step 1: Clear the data of the previous mission.
Mission Example: Prepare
and Start a New Mission
Assumption: The previous mission has been ended by
Step 2: Write the setup data to register page 1.
Step 3: Start the new mission.
using the Stop Mission command. Passwords are not
enabled. The device is a DS1923.
Step 1: Clear the data of the previous mission.
With only a single device connected to the bus master,
the communication of step 1 looks like this:
Starting a mission requires three steps:
MASTER MODE
DATA (LSB FIRST)
(Reset)
COMMENTS
Tx
Rx
Tx
Tx
Tx
Tx
Tx
Rx
Reset pulse
(Presence)
CCh
Presence pulse
Issue “Skip ROM” command
Issue “Clear Memory” command
Send dummy password
Send dummy byte
Reset pulse
96h
<8 FFh bytes>
FFh
(Reset)
(Presence)
Presence pulse
______________________________________________________________________________________ 47
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Step 2: Write the setup data to register page 1.
• Alarm Controls (Response to Conditional Search)
During the setup, the device needs to learn the follow-
ing information:
• General Mission Parameters (e.g., Channels to Log
and Logging Format, Rollover, Start Mode)
• Time and Date
• Sample Rate
• Mission Start Delay
The following data sets up the DS1923 for a mission
that logs temperature and humidity using 8-bit format
for both.
• Alarm Thresholds
DS1923
ADDRESS
0200h
0201h
0202h
0203h
0204h
0205h
0206h
0207h
0208h
0209h
020Ah
020Bh
020Ch
020Dh
020Eh
020Fh
0210h
0211h
0212h
0213h
0214h
0215h
0216h
0217h
0218h
DATA
00h
30h
15h
15h
05h
04h
0Ah
00h
66h
7Ah
6Fh
9Eh
FFh
FFh
FFh
FFh
03h
FFh
01h
C3h
FFh
FFh
5Ah
00h
00h
EXAMPLE VALUES
FUNCTION
15:30:00 hours
Time
15th of May in 2004
Date
Every 10 minutes (EHSS = 0)
Sample rate
10°C Low
20°C High
Temperature Alarm Thresholds
40%RH Low
70%RH High
Humidity Alarm Threshold, no software
correction used
(Don’t care)
Clock through read-only registers
Enable high and low alarm
Enable high and low alarm
Temperature Alarm Control
Humidity Alarm Control
On (enabled), EHSS = 0 (low sample rate)
Normal start; no rollover; 8-bit logging
RTC Oscillator Control, sample rate selection
General Mission Control
(Don’t care)
Clock through read-only registers
90 minutes
Mission Start Delay
48 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
With only a single device connected to the bus master,
the communication of step 2 looks like this:
MASTER MODE
DATA (LSB FIRST)
(Reset)
(Presence)
CCh
COMMENTS
Tx
Rx
Tx
Tx
Tx
Tx
Tx
Tx
Tx
Rx
Tx
Tx
Rx
Rx
Rx
Rx
Tx
Rx
Tx
Tx
Tx
Tx
Tx
Tx
Tx
Rx
Reset pulse
Presence pulse
Issue “Skip ROM” command
Issue “Write Scratchpad” command
TA1, beginning offset = 00h
TA2, address = 0200h
0Fh
00h
02h
<25 Data Bytes>
<7 FFh Bytes>
(Reset)
(Presence)
CCh
Write 25 bytes of data to scratchpad
Write through the end of the scratchpad
Reset pulse
Presence pulse
Issue “Skip ROM” command
Issue “Read Scratchpad” command
Read TA1, beginning offset = 00h
Read TA2, address = 0200h
Read E/S, ending offset = 1Fh, flags = 0h
Read scratchpad data and verify
Reset pulse
AAh
00h
02h
1Fh
<32 Data Bytes>
(Reset)
(Presence)
CCh
Presence pulse
Issue “Skip ROM” command
Issue “Copy Scratchpad” command
TA1
99h
00h
(AUTHORIZATION CODE)
02h
TA2
E/S
1Fh
<8 FFh Bytes>
(Reset)
(Presence)
Send dummy password
Reset pulse
Presence pulse
Step 3: Start the new mission.
If step 3 was successful, the MIP bit in the General
Status register is 1, the MEMCLR bit is 0, and the
Mission Start Delay counts down.
With only a single device connected to the bus master,
the communication of step 3 looks like this:
MASTER MODE
DATA (LSB FIRST)
(Reset)
COMMENTS
Tx
Rx
Tx
Tx
Tx
Tx
Tx
Rx
Reset pulse
(Presence)
CCh
Presence pulse
Issue “Skip ROM” command
Issue “Start Mission” command
Send dummy password
Send dummy byte
Reset pulse
CCh
<8 FFh Bytes>
FFh
(Reset)
(Presence)
Presence pulse
______________________________________________________________________________________ 49
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
The software correction algorithm requires two addition-
al values, which are not stored in the device. For the
DS1923 these values are Tr1 = 60°C and Offset = 41.
Software Correction Algorithm
for Temperature
The accuracy of high-resolution temperature conver-
sion results (forced conversion as well as temperature
logs) can be improved through a correction algorithm.
The data needed for this software correction is stored in
the calibration memory (memory page 18). It consists of
reference temperature (Tr) and conversion result (Tc)
for two different temperatures, as shown below. See the
Temperature Conversion section for the binary number
format.
The correction algorithm consists of two steps, prepara-
tion and execution. The preparation step first converts
temperature data from binary to decimal °C format.
Next, three coefficients A, B, and C are computed. In
the execution step, the temperature reading as deliv-
ered by the DS1923 is first converted from the low/high-
byte format (TcL, TcH) to °C (Tc) and then corrected to
Tcorr. Once step 1 is performed, the three coefficients
can be used repeatedly to correct any temperature
reading and temperature log of the same device.
DS1923
ADDRESS
0240h
0241h
0242h
0243h
0244h
0245h
0246h
0247h
DESIGNATOR
Tr2H
DESCRIPTION
Cold reference temperature, high-byte.
Tr2L
Cold reference temperature, low-byte.
Tc2H
Conversion result at cold reference temperature, high-byte.
Conversion result at cold reference temperature, low-byte.
Hot reference temperature, high-byte.
Tc2L
Tr3H
Tr3L
Hot reference temperature, low-byte.
Tc3H
Conversion result at hot reference temperature, high-byte.
Conversion result at hot reference temperature, low-byte.
Tc3L
Step 1: Preparation
Tr1 = 60
Offset = 41
Tr2 = Tr2H/2 + Tr2L/512 - Offset
Tr3 = Tr3H/2 + Tr3L/512 - Offset
Tc2 = Tc2H/2 + Tc2L/512 - Offset
Tc3 = Tc3H/2 + Tc3L/512 - Offset
Err2 = Tc2 - Tr2
(convert from binary to °C)
(convert from binary to °C)
(convert from binary to °C)
(convert from binary to °C)
Err3 = Tc3 - Tr3
Err1 = Err2
2
2
2
2
2
2
B = (Tr2 - Tr1 ) x (Err3 - Err1)/[(Tr2 - Tr1 ) x (Tr3 - Tr1) + (Tr3 - Tr1 ) x (Tr1 - Tr2)]
2
2
A = B x (Tr1 - Tr2)/(Tr2 - Tr1 )
2
C = Err1 - A x Tr1 - B x Tr1
Step 2: Execution
Tc = TcH/2 + TcL/512 - Offset
(convert from binary to °C)
(the actual correction)
2
Tcorr = Tc - (A x Tc + B x Tc + C)
50 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Numerical Temperature Correction Example
CONVERTED DATA FROM CALIBRATION MEMORY
ERROR VALUES
Tr2 = -10.1297°C
Err2 = 0.0672°C
Err3 = -0.1483°C
Err1 = Err2
Tr3 = 24.6483°C
Tc2 = -10.0625°C
Tc3 = 24.5°C
APPLICATION OF CORRECTION COEFFICIENTS
TO SAMPLE READING
RESULTING CORRECTION COEFFICIENTS
B = -0.008741
A = 0.000175/°C
C = -0.039332°C
Tc = 22.500000°C
Tcorr = 22.647275°C
Note: The software correction requires floating point arithmetic (24-bit or better). Suitable math libraries for microcontrollers are
found on various websites and are included in cross-compilers.
The correction algorithm consists of two steps: prepara-
Software Correction Algorithm
tion and execution. The preparation step first converts
for Humidity
humidity data from binary to decimal %RH format. Next,
The accuracy of humidity conversion results (forced
conversion as well as logged data) can be improved
through a correction algorithm. The data needed for
this software correction is stored in the calibration
memory (memory page 18). It consists of reference
humidity (Hr) and conversion result (Hc) for three differ-
ent humidity levels, as shown below. The data is taken
at 25°C.
three coefficients A, B, and C are computed. In the exe-
cution step the humidity reading as delivered by the
DS1923 (raw data) is first converted from the low/high-
byte format (HcL, HcH) to %RH (Hc) and then correct-
ed to Hcorr. Once step 1 is performed, the three
coefficients can be used repeatedly to correct any
humidity reading and humidity log of the same device.
ADDRESS
0248h
0249h
024Ah
024Bh
024Ch
024Dh
024Eh
024Fh
0250h
0251h
0252h
0253h
DESIGNATOR
Hr1H
DESCRIPTION
Low reference humidity, high byte.
Hr1L
Low reference humidity, low byte.
Hc1H
Hc1L
Conversion result at low reference humidity, high byte.
Conversion result at low reference humidity, low byte.
Medium reference humidity, high byte.
Hr2H
Hr2L
Medium reference humidity, low byte.
Hc2H
Hc2L
Conversion result at medium reference humidity, high byte.
Conversion result at medium reference humidity, low byte.
High reference humidity, high byte.
Hr3H
Hr3L
High reference humidity, low byte.
Hc3H
Hc3L
Conversion result at high reference humidity, high byte.
Conversion result at high reference humidity, low byte.
______________________________________________________________________________________ 51
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Step 1: Preparation
For the humidity data in the calibration memory, the lower 4 bits of each low byte are set to 0. This simplifies the con-
version from the binary data format to raw %RH values to a one-line equation.
Hr1 = ((Hr1H x 256 + Hr1L) x 5.02/65536 - 0.958)/0.0307
Hr2 = ((Hr2H x 256 + Hr2L) x 5.02/65536 - 0.958)/0.0307
Hr3 = ((Hr3H x 256 + Hr3L) x 5.02/65536 - 0.958)/0.0307
Hc1 = ((Hc1H x 256 + Hc1L) x 5.02/65536 - 0.958)/0.0307
Hc2 = ((Hc2H x 256 + Hc2L) x 5.02/65536 - 0.958)/0.0307
Hc3 = ((Hc3H x 256 + Hc3L) x 5.02/65536 - 0.958)/0.0307
Err1 = Hc1 - Hr1
(convert from binary to %RH)
DS1923
Err2 = Hc2 - Hr2
Err3 = Hc3 - Hr3
2
2
2
2
2
2
2
2
B = [(Hr2 - Hr1 ) x (Err3 - Err1) + Hr3 x (Err1 - Err2) + Hr1 x (Err2 - Err1)]/[(Hr2 - Hr1 ) x (Hr3 - Hr1) +
(Hr3 - Hr1 ) x (Hr1 - Hr2)]
2
2
A = [Err2 - Err1 + B x (Hr1 - Hr2)]/(Hr2 - Hr1 )
2
C = Err1 - A x Hr1 - B x Hr1
Step 2: Execution
Hc = ((HcH x 256 + HcL) x 5.02/65536 - 0.958)/0.0307
(convert from binary to %RH)
(the actual correction)
2
Hcorr = Hc - (A x Hc + B x Hc + C)
Numerical Humidity Correction Example
CONVERTED DATA FROM CALIBRATION MEMORY
ERROR VALUES
Hr1 = 20%RH
Hr2 = 60%RH
Hr3 = 90%RH
Hc1 = 17.65%RH
Hc2 = 56.41%RH
Hc3 = 89.57%RH
Err1 = -2.35%RH
Err2 = -3.59%RH
Err3 = -0.43%RH
APPLICATION OF CORRECTION COEFFICIENTS
TO SAMPLE READING
RESULTING CORRECTION COEFFICIENTS
B = -0.186810
A = 0.001948%RH
C = 0.607143%RH
Hc = 8.9%RH
Hcorr = 9.8%RH
Note: The software correction requires floating point arithmetic (24-bit or better). Suitable math libraries for microcontrollers are
found on various websites and are included in cross-compilers.
52 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Temperature compensation uses the following equation:
RH Temperature Compensation
HTcorr = (Hcorr x K + α x (T - 25°C)
The data for the software correction of humidity is taken
at 25°C. Since the temperature characteristics of the
humidity sensor are known, humidity readings taken at
other temperatures can be corrected, provided the
temperature at the time of the humidity conversion is
also known. Therefore, to obtain the most accurate
humidity results, both temperature and humidity should
be logged.
2
2
- β x (T - 25°C) )/(K + γ x (T - 25°C) - δ x (T - 25°C) )
Hcorr is the humidity reading with the software correc-
tion algorithm for humidity already applied, as
explained in the previous section. The function and val-
ues of the other parameters are explained in the table
below.
NAME
FUNCTION
VALUE
T
K
ꢀ
ꢁ
Temperature at the time of humidity conversion.
Humidity sensor conversion constant.
Linear compensation, enumerator.
(in °C)
0.0307
0.0035/°C
2
Quadratic compensation, enumerator.
0.000043/°C
>15°C: 0.00001/°C
ꢃ 15°C: -0.00005/°C
ꢂ
Linear compensation, denominator.
Quadratic compensation, denominator.
2
ꢄ
0.000002/°C
Numerical RH Temperature Compensation Example
SAMPLE INPUT DATA
APPLICATION OF CORRECTION COEFFICIENTS TO SAMPLE READING
ꢀ = 0.00001/°C
T = 70°C
Hcorr = 24.445%RH
2
2
HTcorr = (24.445 x 0.0307 + 0.0035 x 45 - 0.000043 x 45 )/(0.0307 + 0.00001 x 45 - 0.000002 x 45 )
HTcorr = 30.291%
Software Saturation Drift
Compensation
−0.3502 × k
N
∑
0.0156 × ARH × 2.54
k
HScorr = HTcorr −
1+ T − 25 /100
(
)
k=1
k
Capacitive humidity sensors read higher humidity val-
ues than the actual humidity level when they are
exposed to a high-humidity environment for an extend-
ed time period. The DS1923’s humidity sensor pro-
duces readings that are higher than the actual humidity
when exposed to humidity levels of about 70%RH and
higher. This shift continues to increase while the device
remains at 70%RH and above. This effect is called sat-
uration drift, or hysteresis. This drift is reversible.
Readings return to their regular level when the DS1923
is removed from a high-humidity environment.
ARH
The average software-corrected and tempera-
ture-compensated humidity reading of the k
hour that the device is continuously exposed
to 70%RH or higher.
k
th
T
k
The average software-corrected temperature
th
reading of the k hour that the device is
continuously exposed to 70%RH or higher.
N
The number of hours that the device is contin-
uously exposed to 70%RH or higher.
th
HTcorr The humidity reading at the end of the N
hour with the software correction algorithm for
humidity and temperature compensation
already applied. See the Software Correction
Algorithm for Humidity and RH Temperature
Compensation sections for details.
It is possible to compensate for most of the error intro-
duced by the saturation drift by post-processing tem-
perature and humidity logs using the equation below,
which is based on laboratory tests and curve-fitting
techniques.
The numbers in the equation are derived from curve fit-
ting. They apply to a time scale in hours.
______________________________________________________________________________________ 53
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
Numerical Saturation Drift Compensation Example
SAMPLE INPUT DATA (N = 8)
APPLICATION OF CORRECTION ALGORITHM
k (HOUR)
T (°C)
k
ARH (%RH)
k
PARTIAL CORRECTIONS (INDIVIDUAL ADDENDS)
1
2
3
4
5
6
7
8
25.1
91.1
92.5
92.9
93.1
93.2
93.3
93.6
93.7
1.024321
0.751140
0.544824
0.393535
0.283950
0.205086
0.148591
0.107428
25.0
DS1923
24.9
25.0
25.1
25.1
25.0
24.9
HTcorr = 93.70207%RH
Sum of partial corrections:
3.458875
HScorr = HTcorr - Sum of partial corrections
= 93.70207%RH - 3.458875%RH
HScorr = 90.24319%RH
test chamber. The drift per hour decreases the longer
the device is exposed to high humidity. The correction
algorithm compensates for the drift reasonably well. For
some applications, compensation may not be neces-
sary since the error introduced by the saturation is rela-
tively small.
The data in this example was taken from devices that
were exposed for several hours to 90%RH at 25°C in a
Pin Configuration
5.89mm
0.51mm
FRONT-SIDE BRANDING
BACK-SIDE BRANDING
16.25mm
A1
41
®
000000FBC52B
®
1-Wire
Hygrochron™
17.35mm
IO
GND
Package Information
For the latest package outline information and land patterns, go to www.maxim-ic.com/packages.
PACKAGE TYPE
PACKAGE CODE
DOCUMENT NO.
21-0266
F5 iButton
IB-6HB
54 ______________________________________________________________________________________
Hygrochron Temperature/Humidity Logger
iButton with 8KB Data-Log Memory
DS1923
Revision History
REVISION REVISION
PAGES
CHANGED
DESCRIPTION
NUMBER
DATE
0
8/04
Initial release.
—
Changed bullet from “Hydrophobic Filter Protects Sensor Against Dust, Dirt,
Water, and Contaminants” to “Hydrophobic Filter Protects Sensor Against Dust,
Dirt, Contaminants, and Water Droplets/Condensation.”
Deleted “Application Pending” from UL bullet and safety statement.
1
12/07
Added text to the Application section: Note that the initial sealing level of
DS1923 achieves IP56. Aging and use conditions can degrade the integrity of
the seal over time, so for applications with significant exposure to liquids,
sprays, or other similar environments, it is recommended to place the
Hygrochron under a shield to protect it. (See www.maxim-ic.com/AN4126). The
hydrophobic filter may not protect the DS1923 from destruction in the event of
full submersion in liquid.
1, 4, 10
2
3
4/09
Created newer template-style data sheet.
All
1
10/09
Deleted the standard part number from the Ordering Information table.
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 ____________________ 55
© 2009 Maxim Integrated Products
Maxim is a registered trademark of Maxim Integrated Products, Inc.