MAX17201X [MAXIM]

Battery charger or power supply;
MAX17201X
型号: MAX17201X
厂家: MAXIM INTEGRATED PRODUCTS    MAXIM INTEGRATED PRODUCTS
描述:

Battery charger or power supply

电池
文件: 总24页 (文件大小:2553K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
General Description  
Quick Start  
The MAX17201G/MAX17201X/MAX17211G/MAX17211X  
evaluation kits (EV kits) are fully assembled and test-  
ed surface-mount PCBs that evaluate the stand-alone  
ModelGauge™ m5 pack-side fuel-gauge ICs for lithium-  
ion (Li+) batteries in handheld and portable equipment.  
The MAX17201 and MAX17211 are for single-cell appli-  
cations. See the MAX17205 and MAX17215 for multicell  
applications.  
Required Equipment  
MAX17201G/MAX17201X/MAX17211G/MAX17211X  
EV kit  
Lithium battery pack of desired configuration  
Battery charger or power supply  
Load circuit  
DS91230+ USB adapter  
The MAX17201G/MAX17201X/MAX17211G/MAX17211X  
EV kits include the Maxim DS91230+ USB interface, IC  
RJ-11 6pos reverse modular cord  
®
evaluation board, and RJ-11 connection cable. Windows  
PC with Windows 7 or newer windows operating sys-  
based graphical user interface (GUI) software is avail-  
able for use with the EV kit and can be downloaded from  
Maxim’s website www.maximintegrated.com/evkitsoft-  
ware. Windows 7 or newer Windows operating system is  
required to use with the EV kit GUI software.  
tem and USB port  
Procedure  
The EV kits are fully assembled and tested. Follow the  
steps below to install the EV kit software, make required  
hardware connections, and start operation of the kits. The  
EV kit software can be run without hardware attached.  
It automatically locates the hardware when connections  
are made. Note that after communication is established  
the IC must still be configured correctly for the fuel  
gauge to be accurate. See the Configuration Wizard and  
ModelGauge m5 EZ Configuration sections of the GUI  
software description.  
Benefits and Features  
ModelGauge m5 Algorithm  
Nonvolatile Memory Configured for Stand-Alone  
Operation  
Monitors 1S Cell Packs  
Battery Pack Input Voltage Range of +2.1V to +4.9V  
per Cell  
1) Visit www.maximintegrated.com/evkitsoftware to  
downloadthelatestversionoftheMAX17201_05_11_15K  
EV kit software. Save the EV kit software to a temporary  
folder and unpack the ZIP file.  
Thermistor Measurement Network  
Optional On-Board PCB Trace Sense Resistor  
Windows 7 or Newer Compatible Software  
Proven PCB Layout  
2) Install the EV kit software on your computer by run-  
ning the MAX17201_05_11_15K_Install.exe program  
inside the temporary folder. The program files are  
copied and icons are created in the Windows Start  
menu. The software requires the .NET Framework 4.5  
or later. If you are connected to the internet, Windows  
automatically updates .NET framework as needed.  
Fully Assembled and Tested  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X EV Kit Files  
3) The EV kit software launches automatically after in-  
stallation or alternatively it can be launched by click-  
ing on its icon in the Windows Start menu.  
FILE  
DECRIPTION  
MAX17201_05_11_15K_ Installs all EV kit files  
V2_0_0_0_Install.exe on your computer  
4) Connect the DS91230+ adapter to a USB port on the  
PC. The DS91230+ is a HID device and is located  
automatically by Windows without the need to install  
additional drivers.  
Ordering Information appears at end of data sheet.  
Windows is a registered trademarks and registered service  
marks of Microsoft Corporation.  
ModelGauge is a trademark of Maxim Integrated Products, Inc.  
19-8473; Rev 1; 4/16  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
5) Make connections to the EV kit board based on cell  
pack configuration as shown in Figure 1. The cell  
connects between the BAT- and BAT+ pads and the  
charger/load connect between the PACK- and PACK+  
pads. The load or charger circuit can be connected at  
this time as well.  
Communication Connections  
The RJ-11 connector provides all signal lines necessary  
2
for I C, SMBus, 1-Wire, or 1-Wire overdrive communica-  
tion between the IC and the software GUI interface. When  
developing code separately, connections to the commu-  
nication lines can be made directly to the board. Table 1  
summarizes the connections that should be made. The  
user must apply the appropriate external pullup resistors  
to the communication lines when not using the DS91230+  
communication interface.  
6) Connect the RJ-11 cable between the USB adapter  
and the EV kit board. The GUI software establishes  
communication automatically.  
7) If the IC has not been configured, run the Configura-  
tion Wizard in the EV kit software to configure op-  
eration for the desired application circuit and lithium  
cell type. Configuration information is permanently  
saved inside the IC.  
External Thermistors  
The MAX17201/MAX17211 can be configured to use up  
to two external thermistors. All EV kit boards come with  
these thermistors installed as surface mount components  
RT1 and RT2. If the application requires direct thermal  
contact to the cells, RT1 and RT2 can be removed and  
replaced with leaded thermistors connected between the  
RT1+/RT1- and RT2+/RT2- solder pads.  
Detailed Description of Hardware  
The MAX17201/MAX17211 EV kit boards provide a vari-  
ety of features that highlight the functionality of the ICs.  
The following sections detail the most important aspects  
of the kit boards.  
CELL  
CHARGER/  
LOAD  
J2  
ALRT1  
J1  
BAT+  
J6  
J7  
J8  
PROTECTOR  
CIRCUIT  
PACK+ SCL/OD SDA/DQ  
J5  
BAT-  
RJ-11  
PC  
MAX17201/MAX17211  
J14  
J4  
J10 J11  
J12 J13  
PACK-  
CELLx  
RT1- RT1+  
RT2+ RT2-  
Figure 1. MAX17201/MAX17211 Board Connections  
Table 1. Communication Line Solder Points  
MAX17201  
MAX17201  
MAX17211  
J7  
MAX17211  
J8  
COMMUNICATION MODE  
J7  
J8  
2
I C  
SCL  
N/A  
N/A  
SDA  
N/A  
N/A  
N/A  
N/A  
DQ  
DQ  
1-Wire  
Logic-low  
Logic-high  
1-Wire Overdrive  
Maxim Integrated  
2  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Sense Resistor Options  
Detailed Description of Software  
All EV kit boards are shipped with an 0805 size 0.010Ω  
chip sense resistor installed. Oversized land pattern  
pads allow for different size sense resistors to be used  
if desired. Also, each board contains an optional 0.003Ω  
copper trace sense resistor that can be enabled if desired.  
To do so, the chip sense resistor must be removed and 0Ω  
jumpers must be resoldered to change the circuit. Table 2  
summarizes the changes for each board type. Note that  
the IC must be reconfigured to support the new resistor  
type. See the Configuration Wizard section for details.  
The MAX17201G/MAX17201X/MAX17211G/MAX17211X  
evaluation kit software gives the user complete control of  
all functions of the MAX17201/MAX17211, as well as the  
ability to load a custom model into the ICs. It also comes  
with a sophisticated Configuration wizard to allow user to  
easily adjust fuel gauge settings. Separate control tabs  
allow the user access to view real-time updates of all  
monitored parameters. The software also incorporates a  
data-logging feature to monitor a cell over time.  
Software Installation  
The software requires Windows 7 or newer operating  
system. .NET version 4.5 is required for operation and is  
automatically installed if an older version of .NET frame-  
work is detected. To install the evaluation software, exit  
all programs currently running and unzip the provided  
MAX17201_05_11_15K Installation Package zipped file.  
Double click the MAX17201_05_11_15K_V_x_x_x_x  
Install.exe icon and the installation process begins.  
Follow the prompts to complete the installa-  
tion. The evaluation software can be uninstalled in  
the Add/Remove Programs tool in the Control Panel.  
After the installation is complete, open the Maxim  
Integrated/MAX17201_05_11_15K folder and run  
MAX17201_05_11_15K.exe or select it from the pro-  
gram menu. Figure 2 shows a splash screen containing  
information about the evaluation kit that appears as the  
program is being loaded.  
Table 2. Sense Resistor Selection for  
MAX17201/MAX17211  
VALUE FOR  
CHIP SENSE  
VALUE FOR BOARD  
TRACE SENSE  
COMPONENT  
R13  
R14  
0Ω  
Not populated  
Not populated  
0Ω  
Desired sense  
value  
R15  
R16  
Not populated  
0Ω (R17 is trace  
resistor)  
Not populated  
Communication Port  
The EV kit software automatically finds the DS91230+  
adapter when connected to any USB port. Communication  
status is shown on the right-hand side of the bottom sta-  
tus bar. See Figure 3. If the adapter cannot be found, a  
“No USB Adapter” message is displayed. If the adapter is  
found, but the IC daughter board cannot be found, a “No  
Slave Device” message is displayed. Otherwise, if com-  
munication is valid, a green bar updates as the software  
continuously reads the IC registers.  
If the DS91230+ is connected, the status bar should be  
active. The bottom status bar also displays information on  
data logging status, the communication mode, hiberna-  
tion status, selected current-sense resistor value, device  
serial number, and the EVKIT GUI’s version number.  
Figure 2. EV Kit Splash Screen  
Figure 3. EV Kit Bottom Status Bar  
Maxim Integrated  
3  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Program Tabs  
ModelGauge m5 Tab  
All functions of the program are divided under eight tabs  
in the main program window. Click on the appropriate  
tab to move to the desired function page. Located on  
the ModelGauge m5 tab is the primary user information  
measured and calculated by the IC. The Graphs tab  
visually displays fuel gauge register changes over time.  
The Registers and SBS registers tabs allow the user to  
modify common fuel gauge registers one at a time. The  
Commands tab allows for special operations such as  
changing communication mode, initiate fuel gauge log-  
ging and performing fuel gauge reset. The Configuration  
tab displays the value of the nonvolatile registers as  
well as the remaining number of available writes. The  
Authentication tab displays SHA authentication-related  
information. The History tab allows the user to read out  
and save battery history information logged by the IC over  
its lifetime. All tabs are described in more detail in the fol-  
lowing sections.  
The ModelGauge m5 tab displays the important output  
information read from the IC. Figure 4 shows the format  
of the ModelGauge m5 Tab. Information is grouped by  
function and each is detailed separately.  
State of Charge  
The State of Charge group box displays the main output  
information from the fuel gauge: state of charge of the  
cell, remaining capacity, time to full, and time to empty.  
Cell Information  
The Cell Information group box displays information  
related to the health of the cell such as the cell’s age,  
internal resistance, present capacity, number of equivalent  
full cycles, and change in capacity from when it was new.  
Figure 4. ModelGauge m5 Tab  
Maxim Integrated  
4  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
corresponding hypothetical Qresidual, TTE, AvSOC, and  
AvCap values.  
IC Information  
The IC Information group box displays information relat-  
ed to IC itself. This includes the IC part number, IC unique  
ROM ID, and IC firmware revision.  
Graphs Tab  
The Graphs tab displays up to 20 ADC readings and fuel  
gauge outputs. Figure 5 shows the format of the Graphs  
Tab. Graph information is grouped into four categories:  
voltages, temperatures, capacities, and currents. The  
user can turn on or off any data series using the check  
boxes on the right-hand side of the tab. The graph visible  
viewing area can be adjusted from 10 minutes up to 1  
week. The graphs remember up to 1 week worth of data.  
If the viewing area is smaller than the time range of the  
data already collected, the scroll bar below the graphs  
can be used to scroll through graph history. All graph  
history information is maintained by the program. Graph  
settings can be changed at any time without losing data.  
Measurements  
The Measurements group box displays ADC measure-  
ments that are used by the fuel gauge to determine state  
of charge.  
Alerts  
The Alerts group box tracks all eleven possible alert  
trigger conditions. If any alert occurs, the corresponding  
checkbox is checked for the user to see. The clear alerts  
button resets all alert flags.  
At Rate  
The At Rate group box allows user to input a hypo-  
thetical load current and the fuel gauge calculates the  
Figure 5. Graphs Tab  
Maxim Integrated  
5  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
representation of the data stored in the register, and if appli-  
cable a conversion to application units. To write a register  
location click on the button containing the register name.  
A pop-up window allows the user to enter a new value in  
either hexadecimal units or application units. The main  
read loop temporarily pauses while the register updates.  
Registers Tab  
The Registers tab allows the user access to all fuel gauge  
related registers of the IC. Figure 6 shows the format of  
the Registers tab. By using the two buttons on the left  
side of the tab, the user can sort the registers either by  
function or by their internal address. Each line of data  
contains the register name, register address, hexadecimal  
Figure 6. Registers Tab  
Maxim Integrated  
6  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
name, register address, hexadecimal representation of the  
data stored in the register, and if applicable a conversion  
to application units. To write a register location click on  
the button containing the register name. A pop-up window  
allows the user to enter a new value in either hexadecimal  
units or application units. The main read loop temporarily  
pauses while the register updates.  
SBS Registers Tab  
The SBS registers tab is visible only if SBS functions of the  
IC are enabled. The SBS registers tab has the same for-  
matting as the standard Registers tab as shown in Figure  
7. By using the two buttons on the left side of the tab, the  
user can sort the registers either by function or by their  
internal address. Each line of data contains the register  
Figure 7. SBS Registers Tab  
Maxim Integrated  
7  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Commands Tab  
The Commands tab allows the user to access any general IC functions not related to normal writing and reading of  
register locations. Figure 8 shows the format of the Commands tab. Each group box of the Commands tab is described  
in detail in the following sections.  
Figure 8. Commands Tab  
Maxim Integrated  
8  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
1-Wire Communication Speed  
Reset IC  
This option affects 1-wire ICs only. The user can select  
either standard or overdrive communication speed.  
Communication speed is controlled by the EV kit software  
by driving the OD pin of the IC high or low. Regardless of  
the desired communication rate, the kit software commu-  
nicates with any IC it discovers at either communication  
speed. The actual communication speed is displayed in  
the bottom status bar of the EV kit window.  
Clicking the Full Reset button sends the software POR  
command to the command register and sets the POR_  
CMD bit of the Config2 register to fully reset operation  
the same as if the IC had been power cycled. Note that  
resetting the IC when the cell is not relaxed causes fuel  
gauge error.  
Lock Register Blocks  
Clicking one of the five lock buttons locks a page or pages  
of memory as listed to the right of each button. This is a  
permanent operation so the user is prompted to confirm  
the operation prior to setting the lock.  
Read/Write Register  
The user can read a single register location by entering  
the address in hex and clicking the Read button. The  
user can write a single register location by entering the  
address and data in hex and clicking the Write button.  
The read loop is temporarily paused each time to com-  
plete this action.  
Configuration Tab  
The Configuration tab has similar formatting to the stan-  
dard Registers tab as shown in Figure 9, but there are  
some major differences. When the user changes a register  
value on the Configuration tab, only the RAM value of  
that location is changed. The nonvolatile value remains  
unchanged. Register text changes to BLUE to indicate the  
RAM and nonvolatile values do not match. The user must  
complete a nonvolatile burn on the Commands tab or run  
the Configuration Wizard to change the nonvolatile value.  
Log Data to File  
Data logging is always active when the kit software is  
started. The default data log storage location is the My  
Documents/Maxim Integrated/MAX17201_205_211_215/  
Datalog.csv. The user can stop data logging by clicking  
the Stop Log button or change the data log file name by  
clicking the Change Path button. Whenever data logging  
is active, it is displayed on the bottom status bar of the EV  
kit window. All user available IC registers are logging in a  
.csv formatted file. The user can adjust the logging inter-  
val at any time. The user can also enable or disable the  
event logging at any time. When event logging is enabled,  
the data log also stores any IC write or reads that are not  
part of the normal read data loop and indicates any time  
communication to the IC is lost.  
The nonvolatile memory has a limited number of updates  
that is shown in a box on the left-hand side of the tab.  
Maxim recommends using the Configuration Wizard to  
make any changes to nonvolatile memory instead of  
changing registers manually. The wizard can be launched  
through the Device drop-down menu at the top of the EV  
kit software window or by the button on the left-hand side  
of the Configuration tab. See the Configuration Wizard  
section for details.  
Burn Nonvolatile Memory Block  
Note any register information that is displayed in RED  
text indicates a nonvolatile burn error where the data read  
back after a burn does not match the expected value.  
Clicking the Burn NV Block button sends the Copy NV  
Block command to the command register that causes  
all register locations from 180h to 1DFh to be stored to  
nonvolatile memory. Nonvolatile memory has a limited  
number of copies and the user is prompted to confirm  
prior to executing the copy.  
Maxim Integrated  
9  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Figure 9. Configuration Tab  
these values after a compute next secret command to  
what it believes the secret value should be. The secret  
value cannot be written directly or read from the IC. The  
secret value has a limited number of updates that are  
displayed in the changes remaining box. Note that once  
the secret is locked or if the number of remaining updates  
reaches 0, it can no longer be changed.  
Authentication Tab  
The Authentication tab allows the user to perform any  
action related to the SHA 256 authentication feature of the  
IC. Figure 10 shows the format of the Authentication tab.  
Each group box of the Authentication tab is described in  
detail in the following sections.  
SHA Challenge/ROM ID  
SHA Authentication Results  
Enter values into the challenge registers directly or click  
the Randomize Challenge button to fill the challenge  
registers with a completely random value. The challenge  
value is not written to the IC until one of the Compute  
MAC buttons is clicked. The ROM ID is used in some SHA  
calculations so it is displayed here for reference.  
After a SHA operation occurs, the output is displayed in  
the Reported MAC column. The EV kit software calcu-  
lates its own hash and displays the result in the Expected  
MAC column. If the results match, the operation is a suc-  
cess. If the results do not match, it is most likely because  
the secret inside the IC does not match the secret value  
entered into the EV kit software.  
SHA Secret  
Enter the secret value here to allow software to verify the  
SHA calculations of the IC. The EV kit software updates  
Maxim Integrated  
10  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Figure 10. Authentication Tab  
it is displayed to the user starting with page 1. Figure 11  
shows the history tab format.  
Generate Challenge/Response Pairs  
Some applications use challenge-response pairs to con-  
firm battery pack authenticity instead of maintaining the  
secret on the host side. The EV kit software can generate  
a file of any length of random challenge-response pairs  
for use by the application. Ensure to have the correct  
secret entered before generating the pairs.  
Each history page has a status of “BLANK” if it has not yet  
been written, “WRITTEN” if it contains good history data,  
or “SKIPPED” if the IC experienced a write error while  
storing the data. Each history page contains 16 words of  
data. The user can click through each of the 203 history  
pages or enter a page number directly into the box to  
jump to a certain page.  
History Tab  
The History tab allows the user to see all battery history  
logging information stored inside the IC. When the EV kit  
software is loaded, this page is blank. History information  
is not automatically read from the IC. The user must click  
either the Read Battery History button to display history  
data or the Read History and Save to File button to store  
history data in a tab delimited .csv file and then display  
the data. After history data has been read from the IC,  
If a page has been written, all page data is displayed as  
hexadecimal values. Some history information can be  
converted into application units. Those locations contain  
one or two additional boxes of information showing the  
converted values. Value boxes can display “User Data”  
if that location has been configured to store user data  
instead of history information or “A.F. Data” if that location  
is being used for cycle+ age forecasting information.  
Maxim Integrated  
11  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Figure 11. History Tab  
The history information is also displayed in a graph on the  
left side of the tab. The graph displays data only from his-  
tory pages that have been written by the IC. Click on the  
corresponding register name button to change the data  
shown by the graph.  
information that can be programmed into the IC using the  
Configuration Wizard tool. Contact Maxim for details on  
this procedure.  
The second method is ModelGauge m5 EZ configuration.  
This is the default characterization information shipped  
inside every IC. This default model produces accurate  
results for most applications under most operating condi-  
tions. It is the recommended method for new designs as  
it bypasses the custom cell characterization procedure.  
Some additional information is required from the user for  
EZ configuration initialization. The Configuration Wizard  
tool handles this as well.  
ModelGauge m5 EZ Configuration  
Before the IC accurately fuel gauges the battery pack, it  
must be configured with characterization information. This  
can be accomplished two ways.  
The first is through a custom characterization procedure  
that can be performed by Maxim under certain condi-  
tions. The result is an .INI summary file that contains  
Maxim Integrated  
12  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
can click the previous button in the bottom left corner of  
any page to return to any previous step if desired. Once  
the last step is completed, the wizard closes, the IC is  
configured, and a new INI file is saved (if selected).  
Configuration Wizard  
The EV kit software contains a fuel gauge Configuration  
Wizard that can be launched either on the Configuration  
tab or from the Device drop-down menu.The Configuration  
Wizard is the recommended way to change any nonvola-  
tile settings inside the IC. The wizard allows user to:  
Step 1: Starting the Template  
Choose between the existing nonvolatile memory data  
already inside the IC or revert back to the factory default  
values (ModelGauge m5 EZ).  
Open a custom INI file or generate a ModelGauge  
m5 EZ configuration.  
Make any adjustments specific to the application.  
Load the final configuration into the IC.  
Step 2: Cell Model Selection  
Choose between existing model already in the IC’s non-  
volatile memory, the ModelGauge m5 EZ model, or a  
custom model from an INI file by using the Select File  
button. Note that ModelGauge m5 EZ is recommended if  
a custom model is not available.  
Export the generated configuration to a new INI file.  
The Configuration Wizard walks users through an 18 step  
process to configure the IC. Figure 12 shows the first  
page of the wizard. Each step is detailed below. The user  
Figure 12. Configuration Wizard Steps 1 and 2  
Maxim Integrated  
13  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
applications. Die temperature measurements are enabled by  
default if no other measurement channels are enabled..  
Step 3: General Pack Configuration  
Select the configuration that most closely resembles the  
application circuit. The choice made in step 3 determines  
which options are available in step 4 as certain functions  
and ADC channels are not available in certain pack con-  
figurations.  
Step 10: Temperature Measurement Details  
Selections made in step 9 determine which options are  
available in this step. The user must select which tem-  
perature input is used by the fuel gauge. See the nPack-  
Cfg register definition for details. If a thermistor channel is  
enabled then gain, offset, and curve scaling values must  
be used to convert the ADC reading to temperature. If the  
application uses a common thermistor type found in the  
pulldown menu, select that thermistor and the scaling val-  
ues are automatically populated. If the application does  
not use one of these common thermistors, select other  
and enter the scaling values manually.  
Step 4: Specific Pack Configuration Details  
Select the number of series cells in the pack configura-  
tion as well as which ADC channels are used to measure  
pack voltages. If Multicell Inside Protector configuration  
was selected in step 3, cell balancing is possible. The cell  
balancing threshold can be selected from the drop-down  
box. If the application has more than 15 cells in series,  
contact Maxim about configuration options.  
Step 11: Alert Configuration  
Step 5: Shutdown Mode  
Enable the desired alert conditions and then select the desired  
alert thresholds. Note that the current related alert thresholds  
scale based on the sense resistor selection from step 7.  
Select the checkbox if the user intends for the IC to enter  
shutdown mode any time the battery pack is removed  
from the application (communication lines low).  
Step 12: Overcurrent Detection  
Step 6: SBS Compliant Functionality  
Choose the over-discharge (OD) and short-circuit (SC)  
detection settings for the application. Each can be enabled  
independently of other alerts. The user then selects  
a threshold and delay setting. Threshold values scale  
depending on the sense resistor selection from step 7.  
Select the checkbox if user intends to use IC in smart  
battery system (SBS) compliant mode. If SBS mode is not  
used, these device registers are available for general-pur-  
pose data storage in step 16. If SBS mode is enabled, all  
SBS-related configuration settings can be adjusted here.  
Step 13: ALRT Pin Polarity  
Step 7: Sense Resistor Selection  
Choose between active high and active low for the ALRT  
pin’s polarity. ALRT pin polarity is forced to active low if  
either OD or SC comparators are enabled.  
Choose the value of the sense resistor to be used in the  
application. Also, select the resistor temperature com-  
pensation. Maxim recommends disabling temperature  
compensation when using a chip sense resistor. If using a  
PCB signal trace as the sense resistor, the default temper-  
ature coefficient value of 0.4% per °C is ideal for copper.  
Step 14: Cycle+ Age Forecasting  
Enable age forecasting here and then choose the  
DeadTargetRatio and CycleStart for the age forecasting  
function. Note that if age forecasting is enabled, the nVolt-  
Temp and nSOC registers are used to store age forecast-  
ing information and are not available in step 15.  
Step 8: Current Measurement Calibration  
(Optional)  
Current measurement gain calibration is not required for  
proper operation of the fuel gauge. Perform this operation  
calibration step only if the application requires it. To cali-  
brate current, first force a known current of at least one half  
the full-scale value through the sense resistor and enter  
that value into the Forced Current text box. When the  
Current register and AvgCurrent register readings become  
stable, the Auto Calibrate button is enabled to allow  
calibration to occur. Alternatively, the user can adjust gain  
manually by entering a value into the Gain Adjust text box.  
The default value for gain adjust is 1.000 or 100%.  
Step 15: Battery Life Logging  
Enable or disable any of the registers used for Battery Life  
Logging. Any unchecked registers not otherwise used by  
age forecasting are available for general-purpose data  
storage during step 16. The Cycles Per Save box sets  
the rate at which cell history information is data logged  
by the IC.  
Step 16: General-Purpose Data Storage  
Configuration choices in steps 1–15 determine which reg-  
isters are available for general-purpose data storage. The  
user can now enter any data they wish into any nongrey  
register location.  
Step 9: Temperature Measurement Channels  
Select which temperature measurements are used by the appli-  
cation. Die temperature measurement is recommended for all  
Maxim Integrated  
14  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
tion shadow RAM and then restart firmware so that those  
changes take effect. This allows the user to experience the  
new operation of the IC without using one of the limited  
nonvolatile copies. Finally, option three writes the new con-  
figuration to the IC, burns the configuration into nonvolatile  
memory, and then restarts the IC so those changes take  
effect. This option is not available if the IC already used up  
all of the available configuration copies. Additionally, the  
user can store the new configuration options into a new  
INI file for easy programming of additional units. Select the  
desired path name for the new INI file.  
Step 17: Summary of Changes  
After all desired nonvolatile configuration settings have  
been entered by the user, the table in step 17 shows a  
color-coded summary of how the nonvolatile memory  
settings are changed by the new configuration. Note the  
Configuration Wizard automatically converts any mem-  
ory location that matches its alternate default value into  
general-purpose data storage. This can cause changes  
to the nNVCfg0 to nNVCfg2 registers not selected by the  
user, but does not affect IC operation. Figure 13 shows  
an example of the Configuration Wizard summary table.  
The Configuration Wizard completes once the user clicks  
the Done button below step 18. The desired actions from  
step 18 occur after Done is clicked and the wizard closes.  
Click the window close button in the upper right corner of  
the wizard to exit at any time without performing any of the  
actions from step 18.  
Step 18: Update IC and Save New Configuration  
In the final step, the user is given options of how to use the  
new configuration. Figure 14 shows step 18 of the configu-  
ration wizard. Option one is to discard all changes which  
has no effect on the IC. Option two is to write configura-  
Figure 13. Configuration Wizard Step 17  
Maxim Integrated  
15  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Figure 14. Configuration Wizard Step 18  
Maxim Integrated  
16  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Component Suppliers  
SUPPLIER  
PHONE  
WEBSITE  
Murata Electronics North America, Inc.  
770-436-1300  
847-803-6100  
402-563-6866  
www.murata.com/en-us  
www.component.tdk.com  
www.vishay.com  
TDK Corp.  
Vishay  
Note: Indicate that you are using the MAX17201/MAX17205/MAX17211/MAX17215 when contacting these component suppliers.  
Ordering Information  
PART  
TYPE  
EV Kit  
EV Kit  
EV Kit  
EV Kit  
MAX17201GEVKIT#  
MAX17201XEVKIT#  
MAX17211GEVKIT#  
MAX17211XEVKIT#  
#Denotes RoHS compliant.  
Maxim Integrated  
17  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
MAX17201G/MAX17211G Bill of Materials  
PART  
C1  
QTY  
1
DESCRIPTION  
0.1uF ±10%, 50V X7R ceramic capacitor (0402)  
1000pF ±10%, 50V X7R ceramic capacitor (0402), not populated  
1000pF ±10%, 50V X7R ceramic capacitor (0402)  
0.47uF ±10%, 25V X5R ceramic capacitor (0402)  
10Ω ±1%, resistor (0402)  
C2  
C3  
C4  
R1  
1
1
1
1
R2  
1
51.1KΩ ±1%, resistor (0402)  
R4, R5  
2
1KΩ ±1%, resistor (0402)  
R6-R10  
5
150Ω ±1%, resistor (0402)  
R11, R12  
2
10kΩ ±1%, resistor (0402)  
R13  
1
0Ω resistor (0402)  
R14  
R15  
1
1
0Ω resistor (0402), not populated  
0.010Ω ±1%, resistor (0805)  
R16  
RT1, RT2  
D2-D4  
1
2
2
0Ω resistor (0805), not populated  
Thermistor 10K NTC (0402) Murata NCP15XH103F03  
5.6V Zener Diode (SOD323)  
J1-J2, J4-J8, J10-J14  
J9  
J15  
U1  
12  
1
1
1
1
Plated through hole solder pad (16g wire)  
RJ-11,R/A,6-POSITION/6-CONTACTS  
Exposed copper trace jumper  
MAX17201G/MAX17211G Li+ fuel gauge IC 3x3 TDFN 14 pin  
PCB: MAX17201EVKIT/MAX17211EVKIT  
USB-to-RJ11 board DS91230+  
1
1
RJ11 6pos-6pos reverse modular cord 6ft.  
Maxim Integrated  
18  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
MAX17201G/MAX17211G Schematics  
ꢀ$ꢁ75$&(  
-ꢃ %$7ꢋ  
3$&.ꢋ -ꢀ  
5ꢀ  
2'ꢎ6&/ ,1  
6&/ꢎ2' -ꢄ  
6'$ꢎ'4 -ꢑ  
ꢃꢅꢆ  
ꢃꢇ  
5ꢄ  
5ꢃ  
ꢃꢅꢆ  
ꢃꢇ  
$38  
ꢃꢆ  
-ꢏ  
ꢏꢅꢆꢆꢏꢌꢄꢀꢀꢃ  
ꢃꢇ  
$38 ,1  
5ꢑ  
ꢃꢉ  
ꢃꢃ  
9%$77  
5(*ꢐ  
'4ꢎ6'$  
2'ꢎ6&/  
ꢃꢅꢆ  
ꢃꢇ  
'ꢐ  
5ꢃꢆ  
&ꢃ  
ꢆꢈꢃ8)  
$
&
ꢃꢅꢆ  
ꢃꢇ  
ꢅꢈꢀ9  
5ꢏ  
-ꢃꢅ  
5ꢉ  
ꢅꢃꢈꢃ.  
ꢃꢅꢆ  
ꢃꢇ  
,1 2'ꢎ6&/  
5ꢐ  
'ꢉ  
ꢅꢈꢀ9  
&(//ꢃ  
&(//ꢉ  
'1,  
5ꢃꢉ  
ꢃꢍ  
7+50  
,1 57ꢉꢋ  
,1 57ꢃꢋ  
5ꢃꢃ  
ꢃꢆ.  
ꢃꢆ.  
ꢃꢇ  
8ꢃ  
&ꢉ  
'1,  
57ꢃꢌ -ꢃꢆ  
57ꢃꢋ -ꢃꢃ  
0$;ꢃꢄꢉꢆꢃ*ꢋ  
ꢃꢇ  
5ꢍ  
ꢃ.  
ꢃꢇ  
$,1ꢃ  
$,1ꢉ  
57ꢃ  
ꢃꢆ.  
$/57ꢃ  
-ꢉ $/57ꢃ  
-ꢍ &(//;  
ꢃꢆ  
57ꢉꢋ -ꢃꢉ  
57ꢉꢋ  
'ꢍ  
ꢅꢈꢀ9  
,1  
5ꢅ  
5(*ꢉ  
&61  
57ꢉ  
ꢃꢆ.  
ꢃꢐ  
&(//;  
&63  
57ꢉꢌ -ꢃꢐ  
ꢃ.  
ꢃꢇ  
&ꢐ  
ꢃꢆꢆꢆ3)  
&ꢍ  
ꢆꢈꢍꢄ8)  
5ꢃꢐ  
5ꢃꢍ '1,  
,1 6,*Bꢃ  
5ꢃꢅ  
3$&.-ꢃꢍ  
ꢆꢈꢆꢃ  
ꢃꢇ  
ꢀ$ꢁ75$&(  
5ꢃꢀ  
'1,  
5ꢃꢄ  
-ꢅ %$7ꢌ  
ꢂ5ꢃꢄꢁ,6ꢁ$ꢁ%2$5'ꢁ75$&(ꢁ5(6,6725  
,1 6,*Bꢃ  
'
Note the schematic and layout are identical for the MAX17201G and MAX17211G EV kit boards. The only difference between boards  
is IC type and board name silkscreen. The MAX17201G is shown in the following figures.  
Maxim Integrated  
19  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
MAX17201G/MAX17211G PCB Layout  
Component Placement  
Top Layout  
Bottom Layout  
Maxim Integrated  
20  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
MAX17201X/MAX17211X Bill of Materials  
PART  
C1  
QTY  
1
DESCRIPTION  
0.1uF ±10%, 50V X7R ceramic capacitor (0402)  
1000pF ±10%, 50V X7R ceramic capacitor (0402), not populated  
1000pF ±10%, 50V X7R ceramic capacitor (0402)  
0.47uF ±10%, 25V X5R ceramic capacitor (0402)  
10Ω ±1%, resistor (0402)  
C2  
C3  
C4  
R1  
1
1
1
1
R2  
1
51.1KΩ ±1%, resistor (0402)  
R4, R5  
2
1KΩ ±1%, resistor (0402)  
R6-R10  
5
150Ω ±1%, resistor (0402)  
R11, R12  
2
10kΩ ±1%, resistor (0402)  
R13  
1
0Ω resistor (0402)  
R14  
R15  
1
1
0Ω resistor (0402), not populated  
0.010Ω ±1%, resistor (0805)  
R16  
RT1, RT2  
D2-D4  
1
2
2
0Ω resistor (0805), not populated  
Thermistor 10K NTC (0402) Murata NCP15XH103F03  
5.6V Zener Diode (SOD323)  
J1-J2, J4-J8, J10-J14  
J9  
J15  
U1  
12  
1
1
1
1
Plated through hole solder pad (16g wire)  
RJ-11,R/A,6-POSITION/6-CONTACTS  
Exposed copper trace jumper  
MAX17201X/MAX17211X Li+ fuel gauge WLP 15 pin  
PCB: MAX17201XEVKIT/MAX17211XEVKIT  
USB-to-RJ11 board DS91230+  
1
1
RJ11 6pos-6pos reverse modular cord 6ft.  
Maxim Integrated  
21  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
MAX17201X/MAX17211X Schematics  
ꢀꢁ$ꢂ75$&(  
-ꢀ %$7ꢋ  
3$&.ꢋ -ꢉ  
5ꢉ  
2'ꢎ6&/ ,1  
6&/ꢎ2' -ꢄ  
6'$ꢎ'4 -ꢐ  
ꢀꢇꢁ  
ꢀꢊ  
5ꢄ  
5ꢀ  
ꢀꢇꢁ  
ꢀꢊ  
ꢀꢁ  
-ꢍ  
ꢍꢇꢁꢁꢍꢌꢄꢉꢉꢀ  
$38  
,1  
$38  
ꢀꢊ  
,1  
5ꢐ  
%ꢀ  
&ꢀ  
&ꢑ  
&ꢏ  
9%$77  
5(*ꢑ  
'4ꢎ6'$  
2'ꢎ6&/  
5ꢅ  
ꢇꢀꢈꢀ.  
ꢀꢇꢁ  
ꢀꢊ  
'ꢑ  
5ꢀꢁ  
&ꢀ  
ꢁꢈꢀ8)  
$
&
ꢀꢇꢁ  
ꢀꢊ  
ꢇꢈꢉ9  
5ꢍ  
ꢀꢇꢁ  
ꢀꢊ  
,1 2'ꢎ6&/  
'ꢅ  
ꢇꢈꢉ9  
%ꢑ  
%ꢅ  
&(//ꢀ  
&(//ꢅ  
5ꢀꢅ  
%ꢇ  
7+50  
,1 57ꢅꢋ  
,1 57ꢀꢋ  
5ꢀꢀ  
ꢀꢁ.  
ꢀꢁ.  
ꢀꢊ  
8ꢀ  
57ꢀꢌ -ꢀꢁ  
57ꢀꢋ -ꢀꢀ  
0$;ꢀꢄꢅꢁꢀ;ꢋ  
ꢀꢊ  
5ꢏ  
ꢀ.  
ꢀꢊ  
&ꢇ  
%ꢏ  
$,1ꢀ  
$,1ꢅ  
57ꢀ  
ꢀꢁ.  
$ꢇ  
$/57ꢀ  
-ꢅ $/57ꢀ  
-ꢏ &(//;  
57ꢅꢋ -ꢀꢅ  
57ꢅꢋ  
'ꢏ  
ꢇꢈꢉ9  
,1  
5ꢇ  
$ꢀ  
$ꢑ  
5(*ꢅ  
&61  
57ꢅ  
ꢀꢁ.  
&ꢅ  
$ꢏ  
&(//;  
&63  
57ꢅꢌ -ꢀꢑ  
ꢀ.  
ꢀꢊ  
&ꢑ  
ꢀꢁꢁꢁ3)  
*1'  
&ꢏ  
ꢁꢈꢏꢄ8)  
5ꢀꢑ  
5ꢀꢏ '1,  
,1 6,*Bꢀ  
5ꢀꢇ  
3$&.-ꢀꢏ  
ꢁꢈꢁꢀ  
ꢀꢊ  
ꢀꢁ$ꢂ75$&(  
5ꢀꢉ  
'1,  
5ꢀꢄ  
-ꢇ %$7ꢌ  
ꢆ  
(  
ꢃ5ꢀꢄꢂ,6ꢂ$ꢂ%2$5'ꢂ75$&(ꢂ5(6,6725  
,1 6,*Bꢀ  
(1*,1((5ꢒ  
Note the schematic and layout are identical for the MAX17201X and MAX17211X EV kit boards. The only difference between boards  
is IC type and board name silkscreen. The MAX17201X is shown in the following figures.  
Maxim Integrated  
22  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
MAX17201X/MAX17211X PCB Layout  
Component Placement  
Top Layout  
Bottom Layout  
Maxim Integrated  
23  
www.maximintegrated.com  
Evaluate: MAX17201/MAX17211  
MAX17201G/MAX17201X/  
MAX17211G/MAX17211X  
Evaluation Kits  
Revision History  
REVISION REVISION  
PAGES  
CHANGED  
DESCRIPTION  
NUMBER  
DATE  
0
1
3/16  
Initial release  
Removed MAX17205/MAX17215 from EV kit  
4/16  
1–24  
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com.  
Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses  
are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time.  
©
Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc.  
2016 Maxim Integrated Products, Inc.  
24  

相关型号:

MAX17201X+

Power Supply Support Circuit,
MAXIM

MAX17201X+00E

Power Supply Support Circuit,
MAXIM

MAX17201X+T

Power Supply Support Circuit,
MAXIM

MAX17205

Stand-Alone ModelGauge m5 Fuel Gauge
MAXIM

MAX17205G+00E

Power Supply Support Circuit,
MAXIM

MAX17205G+T

Power Supply Support Circuit,
MAXIM

MAX17205G+T0E

Power Supply Support Circuit,
MAXIM

MAX17205X+

Power Supply Support Circuit,
MAXIM

MAX17205X+00E

Power Supply Support Circuit,
MAXIM

MAX17205X+T

Power Supply Support Circuit,
MAXIM

MAX1720EUT

SOT23, Switched-Capacitor Voltage Inverters with Shutdown
MAXIM

MAX1720EUT

Switched Capacitor Voltage Inverter with Shutdown
ONSEMI