HRP-150N-24 [MEANWELL]
150W Single Output wi th PFC Funct ion;型号: | HRP-150N-24 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 150W Single Output wi th PFC Funct ion 功率因数校正 |
文件: | 总5页 (文件大小:161K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
150W Single Output with PFC Function
HRP-150N series
Bauart gepruft
Sicherheit
egelma ge
od
o s
be wac
g
www.tuv.com
ID 2000000000
AS/NZS 62368.1
EN62368-1
TPTC004 IEC62368-1
■ Features
■ Applications
ꢀUniversal AC input / Full range
ꢀIndustrial automation machinery
ꢀIndustrial control system
ꢀBuilt-in active PFC function, PF>0.95
ꢀ250% peak power capability
ꢀHigh efficiency up to 89%
ꢀMechanical and electrical equipment
ꢀDiagnostic or biological facilities
ꢀTest or measurement systems
ꢀTelecommunication equipment
ꢀWithstand 300VAC surge input for 5 seconds
ꢀProtections: Short circuit / Overload / Over voltage /
Over temperature
ꢀCooling by free air convection
ꢀ1U low profile 38mm
ꢀBuilt-in remote sense function
ꢀ5 years warranty
■ Description
HRP-150N is a 150W single output type AC/DC power supply. This series operates for 85~264VAC input
voltage and offers the models with the DC output mostly demanded from the industry. Each model is
cooled by free air convection, working for the temperature up to 70℃ without cover. Moreover, HRP-150N
provides 250% short-duration peak power for motor applications and electromechanical loads requiring
much higher power during start-up.
■ Model Encoding
HRP - 150N - 24
Output voltage(12/24/36/48V)
Rated wattage
Series name
File Name:HRP-150N-SPEC 2020-11-03
150W Single Output with PFC Function
HRP-150N series
SPECIFICATION
MODEL
HRP-150N-36
HRP-150N-12
HRP-150N-24
HRP-150N-48
DC VOLTAGE
12V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
13A
6.5A
4.3A
3.3A
0 ~ 6.5A
0 ~ 4.3A
154.8W
200mVp-p
28.8 ~ 39.6V
1.5%
0 ~ 3.3A
158.4W
240mVp-p
40.8 ~ 55.2V
1.5%
0 ~ 13A
156W
156W
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
10.2 ~ 13.8V
21.6 ~ 28.8V
1.5%
1.5%
0.2%
0.2%
0.2%
0.3%
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
0.5%
0.5%
3000ms, 50ms/230VAC
3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
120 ~ 370VDC
VOLTAGE RANGE
Note.4 85 ~ 264VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF>0.95/230VAC
PF>0.98/115VAC at full load
88%
INPUT
89%
89%
88%
1.7A/115VAC
35A/115VAC
<1mA / 240VAC
0.9A/230VAC
70A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power
on to recover
OVERLOAD
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power
on to recover
PROTECTION
14.4 ~ 16.8V
30 ~ 34.8V
41.4 ~ 48.6V
57.6 ~ 67.2V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-50 ~ +85℃, 10 ~ 95% RH
0.04%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6 5000 meters
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
UL62368-1, TUV EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
Test Level / Note
Conducted
EN55032
Class B
Class B
Class A
-----
Radiated
EN55032
Harmonic current
Voltage Flicker
EN61000-3-2
EN61000-3-3
EMC EMISSION
SAFETY &
EMC
EN55035 , EN61000-6-2(EN50082-2)
(Note 5)
Parameter
ESD
Standard
Test Level / Note
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air; Level 2, 4KV contact
Level 3, 10V/m
RF field
EFT/ Burst
Surge
Level 3, 2KV
EMC IMMUNITY
Level 4, 4KV/Line-FG; 2KV/Line-Line
Level 3, 10V
Conducted
Magnetic Field
Level 4, 30A/m
95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
578.15K hrs min. Telcordia TR/SR-332 (Bellcore) ; 221.71K hrs min. MIL-HDBK-217F (25℃)
MTBF
OTHERS
DIMENSION
PACKING
159*97*38mm (L*W*H)
0.54Kg; 24pcs/12.96Kg/0.9CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
NOTE
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:HRP-150N-SPEC 2020-11-03
150W Single Output with PFC Function
HRP-150N series
Block Diagram
PWM fosc :90KHz
+S
ACTIVE
INRUSH
RECTIFIERS
RECTIFIERS
+V
EMI
FILTER
POWER
&
I/P
&
CURRENT
LIMITING
SWITCHING
-V
PFC
FILTER
-S
DETECTION
CIRCUIT
O.L.P.
O.T.P.
FG
O.T.P.
O.V.P.
PFC
PWM
CONTROL
CONTROL
Derating Curve
Output Derating VS Input Voltage
100
90
80
70
60
50
40
100
80
Without Cover
60
With Cover
Normal load only
40
20
-40
-10
0
10
20
30
40
50
60
70 (HORIZONTAL)
85
100
125
135
155
264
AMBIENT TEMPERATURE (℃)
INPUT VOLTAGE (V) 60Hz
Function Manual
1.Remote Sense
The remote sensing compensates voltage drop on the
load wiring up to 0.5V.
-V -V +V +V
CN100
6 4 2
5 3 1
CN100
NC
NC
NC
NC
+S
-S
6
5
2
1
Sense lines should
be twisted in pairs
LOAD
+S
(Pin2)
-S
(Pin1)
-
+
Fig 1.1
File Name:HRP-150N-SPEC 2020-11-03
150W Single Output with PFC Function
HRP-150N series
2.Peak Power
x
t
(T-t)
35%
x
+
Ppk
Pnpk
P
P
av : Average output power (W)
Pav =
≤
Prated
T
pk : Peak output power (W)
npk : Non-peak output power(W)
rated : Rated output power(W)
t
Duty
x
100%
≤
T
P
P
t
≤
5 sec
t : Peak power width(sec)
T: Period(sec)
Ppk
Pav
Pnpk
t
T
125
40
35
30
25
20
15
10
5
200Vac (1s)
100Vac (5s)
200Vac (5s)
154.8 175
200
225
250
275
300
325
350
375
Peak output power (W)
For example (12V model) :
Vin = 100V Duty_max = 25%
Pav= Prated = 156W
Ppk= 300W
t ≤ 5 sec
T ≧ 20 sec
x t
x
(T-t)
+
Ppk
Pnpk
T
300x5+ Pnpk (20-5)
20
Pav
=
=
≤156W
Pnpk ≤ 108W
File Name:HRP-150N-SPEC 2020-11-03
150W Single Output with PFC Function
HRP-150N series
Mechanical Specification
Case No.901I
Unit:mm
152.5
1
2
3
4
5
6
7
CN100
SVR1
4.5
24
78
159
6.5
150
6-M3(Both Sides) L=6
10 max.
22
117
Connector Pin No. Assignment (CN100) :
Terminal Pin No. Assignment :
Pin No. Assignment Pin No.
HRS DF11-6DP-2DSA or equivalent
Pin No. Assignment Mating Housing
Assignment
Terminal
1
2
3
AC/L
AC/N
FG
4,5
6,7
DC OUTPUT -V
DC OUTPUT +V
1
2
-S
+S
NC
HRS DF11-6DS
or equivalent
HRS DF11-**SC
or equivalent
3~6
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:HRP-150N-SPEC 2020-11-03
相关型号: