HSN-200-5B [MEANWELL]
AC/DC CONVERTER 5V 200W;型号: | HSN-200-5B |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | AC/DC CONVERTER 5V 200W |
文件: | 总3页 (文件大小:588K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
200W Single Output Switching Power Supply
HSN-200 series
■
‧
‧
‧
‧
‧
‧
‧
‧
‧
SPECIFICATION
MODEL
HSN-200-5A
HSN-200-4.2A
HSN-200-4.2B
HSN-200-5B
4.2V
4.2V
5V
5V
DC VOLTAGE
30A
Note.2
40A
0 ~ 40A
168W
150mVp-p
3.6~4.4V
±2.0%
30A
40A
0 ~ 40A
200W
150mVp-p
4.5~5.5V
±2.0%
±0.5%
±2.0%
RATED CURRENT
CURRENT RANGE
0 ~ 30A
126W
150mVp-p
0 ~ 30A
150W
150mVp-p
RATED POWER(convection)
RIPPLE & NOISE (max.) Note.3
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.4
LINE REGULATION
OUTPUT
3.6~4.4V
±2.0%
±0.5%
4.5~5.5V
±2.0%
±0.5%
±0.5%
±2.0%
±2.0%
±2.0%
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
1500ms, 100ms/230VAC 2500ms, 100ms/115VAC
20ms/230VAC 16ms/115VAC at full load
180~264VAC or 254~373VDC
180~264VAC or 254~373VDC
88%
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
90~132VAC or 254~373VDC
47 ~ 63Hz
86.5%
90~132VAC or 254~373VDC
86.5%
88%
INPUT
3.0A/115VAC
2.5A/230VAC
AC CURRENT (Typ.)
COLD START <80A(twidth<1000μs measured at 50% Ipeak) at 115/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
<1mA
A Type:105~185% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
B Type:105~140% rated output power
OVERLOAD
SHORT CIRCUIT
PROTECTION
4.6 ~ 5.4V
5.7 ~ 7.0V
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Shut down O/P voltage, recovers automatically after temperature goes down
-25 ~ +70℃(Refer to "Derating Curve")
OVER TEMPERATURE
WORKING TEMP.
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 60℃)
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, EAC TP TC 004 approved
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
ENVIRONMENT
I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Refer to EN55022 (CISPR22) Class A, EAC TP TC 020
Refer to EN61000-4-5; 4KV, criteria A, EAC TP TC 020
EMC
(Note 5)
EMC IMMUNITY
MTBF
DIMENSION
PACKING
283.069K hrs min. MIL-HDBK-217F (25℃)
210*62*31mm (L*W*H)
0.55kg; 20pcs/12kg/1.63CUFT
OTHERS
NOTE
℃
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:HSN-200-SPEC 2020-09-27
200W Single Output Switching Power Supply
HSN-200 series
Mechanical Specification
CASE NO.:232A
Unit:mm
210
206
2
1
3
SVR1
K
TB1
3
2
1
1
2
LED1
4-ψ3.3
AC Input Terminal(TB1) pin NO. Assignment
DC Output Terminal pin NO. Assignment
Pin No. Assignment
Terminal
Pin No. Assignment
Terminal
1
2
3
AC/L
AC/N
1
2
-V
+V
CPB-7 M5
DG28C-B-03P-13-00AH
Block Diagram
POWER
SWITCH-
ING
SYNCHRONOUS
RECTIFIERS
+V
-V
EMI
FILTER
BRIDGE
RECTIFIERS
I/P
FG
&
FILTER
O.T.P.
DETECTION
CIRCUIT
PWM
CONVERTER
O.L.P.
O.V.P.
Derating Curve
Static Characteristics
fosc=90Khz
Mount with a
40
30
20
10
450*450*3mm
heatsink
100
80
180~264VAC
90~132VAC
60
40
20
(HORIZONTAL)
-25
-10
0
10
30
40
50
60
70
90
180
95
190
100
200
110
220
120
230
125 132
240 264
AMBIENT TEMPERATURE (℃)
INPUT VOLTAGE (V) 60Hz
File Name:HSN-200-SPEC 2020-09-27
HSN-200 series
Installation
1.Operate with additional aluminum plate
In order to meet the“Derating Curve”and the “Static Characteristics” ,HSN-200 series must be installed onto an aluminum plate(or the cabinet of the same size)
on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and
smooth surface (or coated with thermal grease), and HSN-200 series must be firmly mounted at the center of the aluminum plate.
M3*4
4
5
0
2.For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below:
1
3
SVR1
K
5cm
5cm
File Name:HSN-200-SPEC 2020-09-27
相关型号:
©2020 ICPDF网 联系我们和版权申明