NTS-400P-112 [MEANWELL]
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter;型号: | NTS-400P-112 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter |
文件: | 总6页 (文件大小:304K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter
NTS-400P series
User’s Manual
Video
(DC input side)
(AC output side)
E13
AS/NZS 62368.1
TPTC004
IEC62368-1
■ Features
■ Applications
ꢀMobile device
ꢀCompact size and light weight
ꢀTrue sine wave output (THD<3%)
ꢀHigh surge power up to 800W
ꢀ250W convection, 400W forced air
ꢀHome and office appliance
ꢀPortable equipment
ꢀVehicle
ꢀAC output voltage and frequency selectable by DIP S.W
ꢀNo load disspation <1.5W max. at standby saving mode
ꢀ-20℃~+70℃ wide operating temperature
ꢀPower ON-OFF remote control
ꢀYacht
ꢀOff-grid solar power system
ꢀWireless network
ꢀTelecom or datacom system
ꢀProtections :
Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage
Output : Short circuit / Overload / Over temp.
ꢀBattery over discharge protection (Low voltage disconnect)
ꢀSuitable for lead-acid or li-ion batteries
ꢀSupport Tx/Rx for monitoring power inverter status
ꢀConformal coating
ꢀ3 years warranty
■ Description
NTS-400P is a 400W highly reliable built-in type off-grid true sine wave DC-AC power inverter. Its key
features include: digital design with MCU control, streamlined control circuitry that quickly responds to
environmental changes and improves reliability, compact size, light weight, 800W peak power,
adjustable AC output voltage and frequency, -20~+70℃ wide operating temperature range, built-in
remote ON/OFF control, low no-load power consumption (energy saving mode < 1.5W max)., complete
protection features, and etc. Combined with batteries, the NTS-400P is suitable for use in residential,
commercial, marine, automobile, and remote areas with no access to utility power, and the output can be
used to power fans, TV, radio, phone charger, PC/laptop, lighting, outdoor camping equipment, marine
AC power, and etc.
■ Model Encoding
NTS - 400 P - 1 12
DC input voltage (12: 12Vdc, 24: 24Vdc, 48: 48Vdc)
AC output voltage (1: 100/110/115/120Vac, 2:200/220/230/240Vac)
PCB Built-in type
Rated wattage
Series name
File Name:NTS-400P-SPEC 2021-08-04
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter
NTS-400P series
SPECIFICATION
MODEL NO.
NTS-400P-112
NTS-400P-124
NTS-400P-148
NTS-400P-212
NTS-400P-224
NTS-400P-248
RATED POWER(Continuous) 400W
OVER RATED POWER(3 Min.) 460W
PEAK POWER(10 Sec.)
600W
800W
SURGE POWER(30 Cycles)
Default setting set at 110VAC
Default setting set at 230VAC
AC VOLTAGE
FREQUENCY
AC OUTPUT
100 / 110 / 115 / 120Vac selectable by DIP S.W
Default setting set at 60Hz 0.1Hz
50/60Hz selectable by DIP S.W
200 / 220 / 230 / 240Vac selectable by DIP S.W
Default setting set at 50Hz 0.1Hz
50/60Hz selectable by DIP S.W
WAVEFORM
Note.1 True sine wave (THD<3%)
3.0% at rated input voltage
Please refer to page3
AC REGULATION
LED STATUS
24V
48V
24V
48V
DC VOLTAGE
12V
12V
VOLTAGE RANGE (Typ.)
DC CURRENT (Typ.)
10 ~ 16.5Vdc
40A
20 ~ 33Vdc
20A
40 ~ 66Vdc
10A
10 ~ 16.5Vdc
40A
20 ~ 33Vdc
20A
40 ~ 66Vdc
10A
10W
10W
10W
12W
10W
12W
Non-Saving mode
NO LOAD
DISSPATION
(Typ.)
DC INPUT
Default disable, ≦1.2W ~ 1.5W by models @ auto detec AC output load ≦10W will be changed to saving mode
Saving mode
1.2W
1.2W
1.3W
1.5W
1.3W
1.5W
OFF MODE CURRENT DRAW <1mA at battery ~DC input must be disconnected
EFFICIENCY (Typ.)
BATTERY TYPES
FUSE(Internal)
Note.1 89%
Lead Acid or Li-ion
91%
91%
91%
93%
93%
40A*2
30A*2
10A*2
40A*2
30A*2
10A*2
ALARM
11 0.3Vdc
10 0.3Vdc
12.5 0.3Vdc
15.5 0.3Vdc
16.5 0.3Vdc
22 0.5Vdc
20 0.5Vdc
25 0.5Vdc
31 0.5Vdc
33 0.5Vdc
30 0.5Vdc
44 1Vdc
40 1Vdc
50 1Vdc
62 1Vdc
66 1Vdc
60 1Vdc
11 0.3Vdc
10 0.3Vdc
12.5 0.3Vdc
15.5 0.3Vdc
16.5 0.3Vdc
15 0.3Vdc
22 0.5Vdc
20 0.5Vdc
25 0.5Vdc
31 0.5Vdc
33 0.5Vdc
30 0.5Vdc
44 1Vdc
40 1Vdc
50 1Vdc
62 1Vdc
66 1Vdc
60 1Vdc
LOW
HIGH
SHUTDOWN
RESTART
ALARM
SHUTDOWN
RESTART
15 0.3Vdc
By internal fuse open
BAT. POLARITY
OVER TEMPERATURE
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.)
Power ON-OFF remote control by front panel dry contact connector (by RELAY), Open : Normal work ; Short : Remote off
Support Tx/Rx for monitoring power inverter status
REMOTE CONTROL
Tx/Rx
FUNCTION
WORKING TEMP.
-20 ~ +70℃(Refer to “Derating curve”)
20% ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT
-30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
CB IEC62368-1 for all models,E13, EAC TPTC004 for NTS-400P-212/224/248 approved
Design refer to BS EN/EN62368-1, AS/NZS 62368.1 for NTS-400P-212/224/248
DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac
SAFETY STANDARDS
WITHSTAND VOLTAGE
Parameter
Standard
Test Level / Note
FCC for 112,124,148 only
Class A
Radiated
BS EN/EN55032(CISPR32) for 212,224,248 only Class A
EMC EMISSION
SAFETY
&
Harmonic Current
Voltage Flicker
BS EN/EN61000-3-2
BS EN/EN61000-3-3
-----
-----
EMC
(Note.3)
BS EN/EN55024, BS EN/EN55035
Parameter
ESD
Standard
Test Level / Note
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-8
Level 4, 15KV air ; Level 4, 8KV contact
Level 3, 10V/m
EMC IMMUNITY
Radiated
Magnetic Field
Level 4, 30A/m
278.7K hrs min. Telcordia TR/SR-332 (Bellcore) ; 84K hrs min. MIL-HDBK-217F (25℃)
186*100.5*32mm (L*W*H)
MTBF
OTHERS
DIMENSION
PACKING
0.75Kg; 18pcs/ 14.5Kg/ 1.01CUFT
1.Efficiency, AC regulation and THD are tested by 400W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
2.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
3.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
NOTE
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:NTS-400P-SPEC 2021-08-04
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter
NTS-400P series
DERATING CURVE
100
80
60
50
40
Force air with 10CFM fan
Natural convection
-20
0
10
20
30
40
50
60
70 (HORIZONTAL)
AMBIENT TEMPERATURE (℃)
100
80
60
Force air with 10CFM fan
40
20
Natural convection
10Vdc
20Vdc
40Vdc
10.5Vdc
21Vdc
16.5Vdc
33Vdc
42Vdc
66Vdc
Remote ON-OFF Control
Remote ON-OFF
(CN301 PIN1,2)
CN100
AC Output Status
CN301
R.C
power inverter ON
power inverter OFF
Open
Short
1
1
2
2
3
1
2
AC output voltage、Frequency、Power saving mode selectable by DIP SW
Output Voltage and Frequency Setting Factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the
voltage and frequency, through the DIP switch of position 1,2,3,4.
LED
CN50
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
ON
SW4
SW1 SW2
SW3
1 2
3 4
DIP S.W
OFF OFF : 100Vac or 200Vac
OFF ON : 110Vac or 220Vac
ON : 50Hz
ON : Saving mode
ON
ON
OFF : 115Vac or 230Vac
ON : 120Vac or 240Vac
OFF: Non-Saving mode
OFF: 60Hz
Support Tx/Rx for monitoring power inverter status
Users can monitor the status of the power inverter through Tx/Rx, and can modify the input and output parameters set internally.
File Name:NTS-400P-SPEC 2021-08-04
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter
NTS-400P series
LED STATUS
Normal work:
Green
Orange
Red
Remote off
Saving mode
Status
Abnormal Status
Inverter OK
(See below table)
Green
Orange
Red
12.5~15.5Vdc
25~31Vdc
11~12.5Vdc
22~25Vdc
44~50Vdc
<11Vdc or >15.5Vdc
<22Vdc or >31Vdc
<44Vdc or >62Vdc
DC Input
50~62Vdc
Green
Orange
Red
Load
<40% load
40~80% load
>80% load
Abnormal status :
LED Indicator
Abnormal Indication
Status
DC Input
Load
Output overload or AC output short circuit
Status
DC Input
Load
Abnormal DC voltage
Status
DC Input
Load
Over temperature or Fan lock
Status
Inverter fail
DC Input
Load
Light
Light off
Flash
File Name:NTS-400P-SPEC 2021-08-04
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter
NTS-400P series
MECHANICAL SPECIFICATION
Unit:mm
186
32
174.6
5.7
3
φ5.5
(M5)
φ3.5
(M3)
CN500
2
CN301
R.C
1
5cm
26
1
2
1
2
3
CN100
Air flow
direction
LED CN50
4
3
2
3
2
Red
1
TB1
1
φ3.5
(M3)
Black
φ3.5
(M3)
2.5mm(Max.)
Load
DC input
TX RX GND
Status
Pin No.
Pin
Description
Mating Housing
1327FP or equivalent
Terminal
Connect to +
Red
261G2-LPBK
or equivalent
TB1
Black
Connect to -
1327G6FP or equivalent
1
2
3
1
2
1
2
3
Output AC/L
JST VHR
or equivalent
JST SVH-21T-P1.1
or equivalent
Output AC/N
CN500
CN301
CN50
FG
Pin 1,2 Open: Inverter Normal work
Pin 1,2 Short: Inverter Remote off
Signal GND
JST SXH-001T
or equivalent
JST XHP
or equivalent
UART-RX
CHYAO SHIUNN
CHYAO SHIUNN
UART-TX
JS-2001
or equivalent
JS-2001-TX
or equivalent
1
2
3
Fan supply +V
12V/0.4A max.
Fan supply -V
CN100
PWM signal for Fan speed control
DIP SW
Please refer to page3 for more detail
Suggested Fan model: CCHV CHT4012BH-W20D 4020B
File Name:NTS-400P-SPEC 2021-08-04
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter
NTS-400P series
TYPICAL APPLICATION
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
File Name:NTS-400P-SPEC 2021-08-04
相关型号: