NTS-400P-148 [MEANWELL]

400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter;
NTS-400P-148
型号: NTS-400P-148
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter

文件: 总6页 (文件大小:304K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter  
NTS-400P series  
User’s Manual  
Video  
(DC input side)  
(AC output side)  
E13  
AS/NZS 62368.1  
TPTC004  
IEC62368-1  
Features  
Applications  
Mobile device  
Compact size and light weight  
True sine wave output (THD<3%)  
High surge power up to 800W  
250W convection, 400W forced air  
Home and office appliance  
Portable equipment  
Vehicle  
AC output voltage and frequency selectable by DIP S.W  
No load disspation <1.5W max. at standby saving mode  
-20~+70wide operating temperature  
Power ON-OFF remote control  
Yacht  
Off-grid solar power system  
Wireless network  
Telecom or datacom system  
Protections :  
Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage  
Output : Short circuit / Overload / Over temp.  
Battery over discharge protection (Low voltage disconnect)  
Suitable for lead-acid or li-ion batteries  
Support Tx/Rx for monitoring power inverter status  
Conformal coating  
3 years warranty  
Description  
NTS-400P is a 400W highly reliable built-in type off-grid true sine wave DC-AC power inverter. Its key  
features include: digital design with MCU control, streamlined control circuitry that quickly responds to  
environmental changes and improves reliability, compact size, light weight, 800W peak power,  
adjustable AC output voltage and frequency, -20~+70wide operating temperature range, built-in  
remote ON/OFF control, low no-load power consumption (energy saving mode < 1.5W max)., complete  
protection features, and etc. Combined with batteries, the NTS-400P is suitable for use in residential,  
commercial, marine, automobile, and remote areas with no access to utility power, and the output can be  
used to power fans, TV, radio, phone charger, PC/laptop, lighting, outdoor camping equipment, marine  
AC power, and etc.  
Model Encoding  
NTS - 400 P - 1 12  
DC input voltage (12: 12Vdc, 24: 24Vdc, 48: 48Vdc)  
AC output voltage (1: 100/110/115/120Vac, 2:200/220/230/240Vac)  
PCB Built-in type  
Rated wattage  
Series name  
File Name:NTS-400P-SPEC 2021-08-04  
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter  
NTS-400P series  
SPECIFICATION  
MODEL NO.  
NTS-400P-112  
NTS-400P-124  
NTS-400P-148  
NTS-400P-212  
NTS-400P-224  
NTS-400P-248  
RATED POWER(Continuous) 400W  
OVER RATED POWER(3 Min.) 460W  
PEAK POWER(10 Sec.)  
600W  
800W  
SURGE POWER(30 Cycles)  
Default setting set at 110VAC  
Default setting set at 230VAC  
AC VOLTAGE  
FREQUENCY  
AC OUTPUT  
100 / 110 / 115 / 120Vac selectable by DIP S.W  
Default setting set at 60Hz 0.1Hz  
50/60Hz selectable by DIP S.W  
200 / 220 / 230 / 240Vac selectable by DIP S.W  
Default setting set at 50Hz 0.1Hz  
50/60Hz selectable by DIP S.W  
WAVEFORM  
Note.1 True sine wave (THD<3%)  
3.0% at rated input voltage  
Please refer to page3  
AC REGULATION  
LED STATUS  
24V  
48V  
24V  
48V  
DC VOLTAGE  
12V  
12V  
VOLTAGE RANGE (Typ.)  
DC CURRENT (Typ.)  
10 ~ 16.5Vdc  
40A  
20 ~ 33Vdc  
20A  
40 ~ 66Vdc  
10A  
10 ~ 16.5Vdc  
40A  
20 ~ 33Vdc  
20A  
40 ~ 66Vdc  
10A  
10W  
10W  
10W  
12W  
10W  
12W  
Non-Saving mode  
NO LOAD  
DISSPATION  
(Typ.)  
DC INPUT  
Default disable, 1.2W ~ 1.5W by models @ auto detec AC output load 10W will be changed to saving mode  
Saving mode  
1.2W  
1.2W  
1.3W  
1.5W  
1.3W  
1.5W  
OFF MODE CURRENT DRAW <1mA at battery ~DC input must be disconnected  
EFFICIENCY (Typ.)  
BATTERY TYPES  
FUSE(Internal)  
Note.1 89%  
Lead Acid or Li-ion  
91%  
91%  
91%  
93%  
93%  
40A*2  
30A*2  
10A*2  
40A*2  
30A*2  
10A*2  
ALARM  
11 0.3Vdc  
10 0.3Vdc  
12.5 0.3Vdc  
15.5 0.3Vdc  
16.5 0.3Vdc  
22 0.5Vdc  
20 0.5Vdc  
25 0.5Vdc  
31 0.5Vdc  
33 0.5Vdc  
30 0.5Vdc  
44 1Vdc  
40 1Vdc  
50 1Vdc  
62 1Vdc  
66 1Vdc  
60 1Vdc  
11 0.3Vdc  
10 0.3Vdc  
12.5 0.3Vdc  
15.5 0.3Vdc  
16.5 0.3Vdc  
15 0.3Vdc  
22 0.5Vdc  
20 0.5Vdc  
25 0.5Vdc  
31 0.5Vdc  
33 0.5Vdc  
30 0.5Vdc  
44 1Vdc  
40 1Vdc  
50 1Vdc  
62 1Vdc  
66 1Vdc  
60 1Vdc  
LOW  
HIGH  
SHUTDOWN  
RESTART  
ALARM  
SHUTDOWN  
RESTART  
15 0.3Vdc  
By internal fuse open  
BAT. POLARITY  
OVER TEMPERATURE  
OUTPUT SHORT  
Protection type : Shut down o/p voltage, re-power on to recover  
Protection type : Shut down o/p voltage, re-power on to recover  
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.  
Protection type : Shut down o/p voltage, re-power on to recover  
OVER LOAD (Typ.)  
Power ON-OFF remote control by front panel dry contact connector (by RELAY), Open : Normal work ; Short : Remote off  
Support Tx/Rx for monitoring power inverter status  
REMOTE CONTROL  
Tx/Rx  
FUNCTION  
WORKING TEMP.  
-20 ~ +70(Refer to “Derating curve”)  
20% ~ 90% RH non-condensing  
WORKING HUMIDITY  
ENVIRONMENT  
-30 ~ +70/ -22 ~ +158oF, 10 ~ 95% RH non-condensing  
STORAGE TEMP., HUMIDITY  
VIBRATION  
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes  
CB IEC62368-1 for all models,E13, EAC TPTC004 for NTS-400P-212/224/248 approved  
Design refer to BS EN/EN62368-1, AS/NZS 62368.1 for NTS-400P-212/224/248  
DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
Parameter  
Standard  
Test Level / Note  
FCC for 112,124,148 only  
Class A  
Radiated  
BS EN/EN55032(CISPR32) for 212,224,248 only Class A  
EMC EMISSION  
SAFETY  
&
Harmonic Current  
Voltage Flicker  
BS EN/EN61000-3-2  
BS EN/EN61000-3-3  
-----  
-----  
EMC  
(Note.3)  
BS EN/EN55024, BS EN/EN55035  
Parameter  
ESD  
Standard  
Test Level / Note  
BS EN/EN61000-4-2  
BS EN/EN61000-4-3  
BS EN/EN61000-4-8  
Level 4, 15KV air ; Level 4, 8KV contact  
Level 3, 10V/m  
EMC IMMUNITY  
Radiated  
Magnetic Field  
Level 4, 30A/m  
278.7K hrs min. Telcordia TR/SR-332 (Bellcore) ; 84K hrs min. MIL-HDBK-217F (25)  
186*100.5*32mm (L*W*H)  
MTBF  
OTHERS  
DIMENSION  
PACKING  
0.75Kg; 18pcs/ 14.5Kg/ 1.01CUFT  
1.Efficiency, AC regulation and THD are tested by 400W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.  
2.All parameters not specified above are measured at rated load, 25of ambient temperature and set to factory setting.  
3.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
NOTE  
Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx  
File Name:NTS-400P-SPEC 2021-08-04  
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter  
NTS-400P series  
DERATING CURVE  
100  
80  
60  
50  
40  
Force air with 10CFM fan  
Natural convection  
-20  
0
10  
20  
30  
40  
50  
60  
70 (HORIZONTAL)  
AMBIENT TEMPERATURE ()  
100  
80  
60  
Force air with 10CFM fan  
40  
20  
Natural convection  
10Vdc  
20Vdc  
40Vdc  
10.5Vdc  
21Vdc  
16.5Vdc  
33Vdc  
42Vdc  
66Vdc  
Remote ON-OFF Control  
Remote ON-OFF  
(CN301 PIN1,2)  
CN100  
AC Output Status  
CN301  
R.C  
power inverter ON  
power inverter OFF  
Open  
Short  
1
1
2
2
3
1
2
AC output voltageFrequencyPower saving mode selectable by DIP SW  
Output Voltage and Frequency Setting Factory settings are either 110Vac/60Hz or 230Vac/50Hz, users are able to adjust the  
voltage and frequency, through the DIP switch of position 1,2,3,4.  
LED  
CN50  
AC Output VoltageFrequencyPower saving mode selectable by DIP SW  
ON  
SW4  
SW1 SW2  
SW3  
1 2  
3 4  
DIP S.W  
OFF OFF : 100Vac or 200Vac  
OFF ON : 110Vac or 220Vac  
ON : 50Hz  
ON : Saving mode  
ON  
ON  
OFF : 115Vac or 230Vac  
ON : 120Vac or 240Vac  
OFF: Non-Saving mode  
OFF: 60Hz  
Support Tx/Rx for monitoring power inverter status  
Users can monitor the status of the power inverter through Tx/Rx, and can modify the input and output parameters set internally.  
File Name:NTS-400P-SPEC 2021-08-04  
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter  
NTS-400P series  
LED STATUS  
Normal work:  
Green  
Orange  
Red  
Remote off  
Saving mode  
Status  
Abnormal Status  
Inverter OK  
(See below table)  
Green  
Orange  
Red  
12.5~15.5Vdc  
25~31Vdc  
11~12.5Vdc  
22~25Vdc  
44~50Vdc  
<11Vdc or >15.5Vdc  
<22Vdc or >31Vdc  
<44Vdc or >62Vdc  
DC Input  
50~62Vdc  
Green  
Orange  
Red  
Load  
<40% load  
40~80% load  
>80% load  
Abnormal status :  
LED Indicator  
Abnormal Indication  
Status  
DC Input  
Load  
Output overload or AC output short circuit  
Status  
DC Input  
Load  
Abnormal DC voltage  
Status  
DC Input  
Load  
Over temperature or Fan lock  
Status  
Inverter fail  
DC Input  
Load  
Light  
Light off  
Flash  
File Name:NTS-400P-SPEC 2021-08-04  
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter  
NTS-400P series  
MECHANICAL SPECIFICATION  
Unit:mm  
186  
32  
174.6  
5.7  
3
φ5.5  
(M5)  
φ3.5  
(M3)  
CN500  
2
CN301  
R.C  
1
5cm  
26  
1
2
1
2
3
CN100  
Air flow  
direction  
LED CN50  
4
3
2
3
2
Red  
1
TB1  
1
φ3.5  
(M3)  
Black  
φ3.5  
(M3)  
2.5mm(Max.)  
Load  
DC input  
TX RX GND  
Status  
Pin No.  
Pin  
Description  
Mating Housing  
1327FP or equivalent  
Terminal  
Connect to +  
Red  
261G2-LPBK  
or equivalent  
TB1  
Black  
Connect to -  
1327G6FP or equivalent  
1
2
3
1
2
1
2
3
Output AC/L  
JST VHR  
or equivalent  
JST SVH-21T-P1.1  
or equivalent  
Output AC/N  
CN500  
CN301  
CN50  
FG  
Pin 1,2 Open: Inverter Normal work  
Pin 1,2 Short: Inverter Remote off  
Signal GND  
JST SXH-001T  
or equivalent  
JST XHP  
or equivalent  
UART-RX  
CHYAO SHIUNN  
CHYAO SHIUNN  
UART-TX  
JS-2001  
or equivalent  
JS-2001-TX  
or equivalent  
1
2
3
Fan supply +V  
12V/0.4A max.  
Fan supply -V  
CN100  
PWM signal for Fan speed control  
DIP SW  
Please refer to page3 for more detail  
Suggested Fan model: CCHV CHT4012BH-W20D 4020B  
File Name:NTS-400P-SPEC 2021-08-04  
400W High Reliable Built-in Type True Sine Wave DC-AC Power Inverter  
NTS-400P series  
TYPICAL APPLICATION  
INSTALLATION MANUAL  
Please refer to : http://www.meanwell.com/manual.html  
File Name:NTS-400P-SPEC 2021-08-04  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY