PSC-100_V01 [MEANWELL]
100W Single Output with Battery Charger(UPS Function);型号: | PSC-100_V01 |
厂家: | MEAN WELL ENTERPRISES CO., LTD. |
描述: | 100W Single Output with Battery Charger(UPS Function) 电池 |
文件: | 总3页 (文件大小:892K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
100W Single Output with Battery Charger(UPS Function)
PSC-100 series
‧
‧
‧
‧
‧
‧
‧
‧
Bauart gepruft
Sicherheit
‧
egelma ge
od
o s
g
be wac
www.tuv.com
ID 2000000000
SPECIFICATION
UL62368-1
BS EN/EN62368-1 TPTC004 IEC62368-1
MODEL
PSC-100A
PSC-100B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
4.75A
0 ~ 7A
100.05W
13.8V
2.5A
--------
27.6V
2.4A
27.6V
1.25A
--------
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 ±1.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0 ~ 3.5A
100.74W
100mVp-p
CH1: 24 ~ 29V
±1.0%
--------
--------
OUTPUT
CH1: 12 ~ 15V
--------
--------
--------
--------
--------
--------
±0.5%
±0.5%
±0.5%
±0.5%
Note.4 2400ms, 30ms/230VAC
2400ms, 30ms/115VAC at full load
14ms/115VAC at full load
127 ~ 370VDC
40ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
86%
2A/115VAC
COLD START 35A/115VAC
88%
INPUT
1.2A/230VAC
70A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVERLOAD
CH1:14.49 ~ 18.63V
Protection type : Shut down o/p voltage, re-power on to recover
CH1:28.98 ~ 37.26V
PROTECTION
OVER VOLTAGE
20±1V
10±0.5V
BATTERY CUT OFF
Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A
Note.6
AC OK
ALARM
FUNCTION
Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A
BATTERY LOW
Battery low voltage : < 11V
Battery low voltage : < 22V
-20 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0~50℃) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, criteria A, EAC TP TC 020
417.6K hrs min. MIL-HDBK-217F (25℃)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
MTBF
PCB:127*76.2*31mm (L*W*H) ; Enclosed type:130*85*37mm (L*W*H)
PCB:0.23Kg; 63pcs/15.5Kg/1.28CUFT ; Enclosed type:0.44Kg;32pcs/15Kg/0.73CUFT
¢
OTHERS
NOTE
DIMENSION
PACKING
(as available on http://www.meanwell.com)
、
℃℃
※:https://www.meanwell.com/serviceDisclaimer.aspx
File Name:PSC-100-SPEC 2021-06-21
100W Single Output with Battery Charger(UPS Function)
PSC-100 series
Mechanical Specification
Unit:mm
Cover:
No. 946B-T
M2
CN2
AC FUSE
1
2
3
4
5
6
7
8
T3.15A/250V
FS1
3
2
1
CN1
1
2
3
4
CN3
SVR1
M1
HS2
HS3
M3
115.8
127
5.6
Mylar film
8
1
7
.
1
2
-
M
3 L
=
4
1
1
5
.
8
2
-
M
3
7
3
2
.
8
7
.
1
4
6
.
8
5
6
8
L-Bracket:
No. 946A-D
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. Assignment
Mating Housing
Terminal
Alarm Output Connector(CN3) : JST B4B-XH or equivalent
1
2
3
AC/N
No Pin
AC/L
JST VHR
JST SVH-21T-P1.1
or equivalent
Pin No. Assignment
Mating Housing
Terminal
or equivalent
1
3
2
4
AC OK
JST SXH-001T-P0.6
or equivalent
JST XHP
or equivalent
DC Output Connector (CN2) : JST B8P-VH or equivalent
Pin No. Assignment
Bat. Low
Mating Housing
Terminal
1,2
3,4
5,6
7,8
-V
+V
Bat+
Bat-
JST VHR
JST SVH-21T-P1.1
or equivalent
or equivalent
: Grounding Required
Block Diagram
AC OK
RL1
RL2
ALARM
CIRCUIT
Bat. Low
EMI FILTER
&
RECTIFIERS
POWER
SWITCHING
+V
-V
Bat. +
I/P
FG
&
RECTIFIER
FILTER
DETECTION
CIRCUIT
Bat. -
PWM
Battery Charger
&
O.L.P.
CONTROL
O.V.P.
Back up Control
File Name:PSC-100-SPEC 2021-06-21
100W Single Output with Battery Charger(UPS Function)
PSC-100 series
Output Derating
Output Derating VS Input Voltage
100
90
100
80
PCB only
PCB only
Enclosed type
80
Enclosed tpye
60
50
40
70
60
50
40
20
(HORIZONTAL)
70
-20
0
10
20
30
40
50
60
90 95 100 115 120 140 160 180 200 220 240 264
AMBIENT TEMPERATURE (¢)
INPUT VOLTAGE (VAC) 60Hz
Suggested Application
1.Backup connection for AC interruption
(1) Please refer to the Fig1.1 for suggested connection.
The power supply charges the battery and provides energy to the load at the same time when the AC main is OK.
The battery starts to supply power to the load when the AC mains fails.
-V
-
+
Load
+V
Bat+
Bat-
A : 12V
B : 24V
+
-
Battery
Fig 1.1 Suggested system connection
2.Alarm signal for AC OK and Battery Low
(1) Alarm signal is sent out through " AC OK " & " Battery Low " pins.(relay contact type)
(2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A.
(3) Table2.1 explains the alarm function built in the power supply
AC OK (Battery low)
CN3 Pin1(Pin3)
Function
Description
Output of Alarm
Low or short
The signal is "Low" when the power supply
turns on
AC OK
High or open(External applied
voltage 30V max.)
The signal turns to be "High" when the power
supply turns OFF
R
V
The signal is "Low" when the voltage of
battery is under A:11V, B:22V
Low or short
Battery
Low
High or open(External applied
voltage 30V max.)
The signal is "High" when the voltage of
battery is above A:11V, B:22V
CN3 Pin2(Pin4)
External voltage source (V)
and resistor (R)
(The max. Sink is 1A and 30V)
Table 2.1 Explanation of Alarm Signal
Fig 2.2 Internal circuit of AC OK (Battery Low)
(4) RL1 (AC OK)signal will go into hiccup mode when the overload protection is activating.