RSDW20G-03 [MEANWELL]

20W 2x1 Package Reliable Railway DC-DC Converter;
RSDW20G-03
型号: RSDW20G-03
厂家: MEAN WELL ENTERPRISES CO., LTD.    MEAN WELL ENTERPRISES CO., LTD.
描述:

20W 2x1 Package Reliable Railway DC-DC Converter

文件: 总6页 (文件大小:141K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
20W 2"x1" Package Reliable Railway DC-DC Converter  
RSDW20 & RDDW20 series  
Applications  
Features  
Bus, tram, metro or railway system  
Telecom/datacom system  
Wireless network  
Compliance with EN50155 railway standard  
DIP 2"x1" package with standard pinout  
4:1 wide input range  
Wide operating temperature range -40 ~ +85℃  
No minimum load required  
Industrial control facility  
Instrument  
Full encapsulated  
Analyzer  
Protections: Short circuit (Continuous) / Overload /  
Over voltage / Input under voltage  
1.5KVDC,3KVDC I/O isolation by models  
Remote ON/OFF control  
Highly vibrating, heavily dusty, exteremely  
low or hightemperature harsh environment  
3 years warranty  
Description  
RSDW20 and RDDW20 series are 20W module type DC-DC reliable railway converter with 2"x1" package. It  
features international standard pins, a high efficiency up to 90%, wide working temperature range  
-40~+85, 1.5KVDC(F/G models)/3KVDC(H models) I/P-O/P isolation voltage, compliance with EN50155  
railway standard, continuous-mode short circuit protection, etc. The models account for different input  
voltage 9~36V, 18~75V and 43~160V 4:1 wide input range, and various output voltage, 3.3V/5V/12V/15V  
for single output and ±5V/±12V/±15V for dual outputs, which are suitable for railway, trams, buses and also  
can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.  
Model Encoding  
R S DW20H  
-12  
Output voltage (3.3/5/12/15Vdc±5/±12/±15Vdc)  
Input voltage (F: 9~36VdcG: 18~75VdcH: 43~160Vdc)  
Rated wattage  
S:Single output  
D:Dual output  
Series name  
{
File Name:RSDW20,RDDW20-SPEC 2018-08-06  
20W 2"x1" Package Reliable Railway DC-DC Converter  
RSDW20 & RDDW20 series  
MODEL SELECTION TABLE  
INPUT  
OUTPUT  
EFFICIENCY CAPACITOR LOAD  
OUTPUT  
ORDER NO.  
INPUT CURRENT  
INPUT VOLTAGE  
(RANGE)  
OUTPUT  
(Typ.)  
(MAX.)  
VOLTAGE  
CURRENT  
NO LOAD  
FULL LOAD  
RSDW20F-03  
RSDW20F-05  
RSDW20F-12  
RSDW20F-15  
RDDW20F-05  
RDDW20F-12  
RDDW20F-15  
RSDW20G-03  
RSDW20G-05  
RSDW20G-12  
RSDW20G-15  
RDDW20G-05  
RDDW20G-12  
RDDW20G-15  
RSDW20H-05  
RSDW20H-12  
RSDW20H-15  
RDDW20H-12  
RDDW20H-15  
55mA  
55mA  
55mA  
55mA  
70mA  
35mA  
35mA  
25mA  
25mA  
25mA  
25mA  
45mA  
25mA  
25mA  
3mA  
869mA  
3.3V  
5V  
5500mA  
87%  
90%  
90%  
90%  
89%  
88%  
88%  
88%  
89%  
90%  
90%  
89%  
88%  
88%  
88.5%  
90%  
89.5%  
89%  
88.5%  
5500μF  
4000μF  
935mA  
928mA  
935mA  
945mA  
947mA  
935mA  
430mA  
465mA  
465mA  
465mA  
468mA  
470mA  
470mA  
205mA  
202mA  
203mA  
206mA  
206mA  
4000mA  
12V  
1670mA  
1800μF  
Normal 24V  
(9 ~ 36V)  
15V  
1330mA  
1500μF  
± 5V  
± 12V  
± 15V  
3.3V  
5V  
± 0 ~ 2000mA  
± 0 ~835mA  
± 0 ~ 666mA  
5500mA  
*2000μF  
*1000μF  
*800μF  
5500μF  
4000mA  
4000μF  
12V  
1670mA  
1800μF  
Normal 48V  
(18 ~ 75V)  
15V  
1330mA  
1500μF  
± 5V  
± 12V  
± 15V  
5V  
± 0 ~ 2000mA  
± 0 ~835mA  
± 0 ~ 666mA  
4000mA  
*2000μF  
*1000μF  
*800μF  
5600μF  
3mA  
12V  
1670mA  
1000μF  
Normal 110V  
(43 ~ 160V)  
3mA  
15V  
1330mA  
1000μF  
3mA  
± 12V  
± 15V  
± 0 ~1833mA  
± 0 ~ 667mA  
*680μF  
3mA  
*350μF  
* For each output  
File Name:RSDW20,RDDW20-SPEC 2018-08-06  
20W 2"x1" Package Reliable Railway DC-DC Converter  
RSDW20 & RDDW20 series  
SPECIFICATION  
VOLTAGE RANGE  
SURGE VOLTAGE (100ms max.) 24Vin models : 50Vdc, 48Vin models : 100Vdc, 110Vin models : 200Vdc  
F: 9~36Vdc , G: 18~75Vdc , H: 43~160Vdc  
INPUT  
FILTER  
Pi type  
PROTECTION  
VOLTAGE ACCURACY  
RATED POWER  
Fuse recommended. 24Vin models: 4A delay time Type, 48Vin models: 2A delay time Type, 110Vin models: 0.8A delay time Type  
± 1.5%  
20W  
RIPPLE & NOISE Note.2 60mVp-p  
LINE REGULATION Note.3 ± 0.2%  
OUTPUT  
LOAD REGULATION Note.4 Single output models: ± 0.5%, Dual output models:± 1%  
F/G: Single output 350KHz, Dual output 400KHz  
SWITCHING FREQUENCY (Typ.)  
H: 250KHz  
EXTERNAL TRIM ADJ. RANGE (Typ.) ± 10% (Single output model only)  
SHORT CIRCUIT  
OVERLOAD  
Protection type : Continuous, automatic recovery  
110 ~ 160% rated output power  
Protection type : Recovers automatically after fault condition is removed  
Protection type : Clamp by diode  
PROTECTION  
FUNCTION  
OVER VOLTAGE  
UNDER VOLTAGE LOCKOUT  
Start-up voltage  
24Vin: 8.8Vdc, 48Vin: 17Vdc, 110Vin: 40Vdc  
24Vin: 8Vdc, 48Vin: 16Vdc, 110Vin: 38Vdc  
Shutdown voltage  
Power ON: >5.5~75Vdc or open circuit (F/G models) ; >3.5~75Vdc or open circuit (H models)  
Power OFF: <1.2Vdc or short (F/G/H models)  
REMOTE CONTROL  
Free-air convection  
COOLING  
-40 ~ +85(Refer to "Derating Curve")  
+105max.  
WORKING TEMP.  
CASE TEMPERATURE  
WORKING HUMIDITY  
STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
SOLDERING TEMPERATURE  
VIBRATION  
20% ~ 90% RH non-condensing  
-55 ~ +125, 10 ~ 95% RH non-condensing  
0.03% / (0 ~ 71)  
ENVIRONMENT  
1.5mm from case of 1 ~ 3sec./260max.  
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes  
EAC TP TC 004 approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
ISOLATION CAPACITANCE (Typ.)  
F/G: I/P-O/P 1.5KVDC, H: I/P-O/P 3KVDC  
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH  
1000pF  
Parameter  
Conducted  
Radiated  
Standard  
Test Level / Note  
EN55032  
Class A/B with external components  
N/A  
EMC EMISSION  
EN55032  
SAFETY &  
Parameter  
ESD  
Standard  
Test Level / Note  
EMC  
( Note.5)  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
Level 2, ± 8KV air, ± 4KV contact  
Level 2, 3V/m  
Radiated Susceptibility  
EFT/Burest  
Surge  
EMC IMMUNITY  
Level 1, 0.5KV  
Level 1, 0.5KV Line-Line  
Level 2, 3V(e.m.f.)  
Conducted  
RAILWAY STANDARD  
MTBF  
EN50155 / IEC60571 including EN61373 for shock & vibration, EN50121-3-2 for EMC  
F/G: 720Khrs ; H: 880Khrs MIL-HDBK-217F(25)  
50.8*25.4*10.2mm (2*1*0.4 inch)  
DIMENSION (L*W*H)  
CASE MATERIAL  
PACKING  
OTHERS  
NOTE  
Black coated copper with Non-Conductive Base  
35g  
1.All parameters are specified at normal input(F:24Vdc, G:48Vdc, H:110Vdc), rated load, 2570% RH ambient.  
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.  
3.Line regulation is measured from low line to high line at rated load.  
4.Load regulation is measured from 0% to 100% rated load.  
5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please  
refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)  
File Name:RSDW20,RDDW20-SPEC 2018-08-06  
20W 2"x1" Package Reliable Railway DC-DC Converter  
RSDW20 & RDDW20 series  
External Output Trimming  
In order to trim the voltage up or down one needs to connect the trim resistor either between the trim pin and -Vo for trim-up and between trim pin and  
+Vo for trim-down. The output voltage trim range is ± 10%. This is shown in Figures 1 and 2:  
+Vo  
+Vo  
+Vin  
+Vin  
R trim-down  
R-Load  
Trim  
R-Load  
R trim-up  
Trim  
-Vo  
-Vin  
-Vin  
-Vo  
Figure 1. Trim-up Voltage Setup  
Figure 2. Trim-down Voltage Setup  
Mechanical Specification  
Plug Assignment  
All dimensions in mm(inch)  
Tolerance:x.x± 0.5mm(x.xx± 0.02")  
x.xx± 0.25mm(x.xxx± 0.010")  
Pin size is:0.5± 0.05mm (0.02±± 0.002")  
F models(9~36Vin) and G models(18~75Vin):  
5.08  
(0.2)  
7.62(0.3)  
10.16(0.4)  
Pin-Out  
RSDW20F/G RDDW20F/G  
(Single output) (Dual output)  
Pin No.  
6
5
2
1
1
2
3
4
5
6
+Vin  
-Vin  
+Vin  
-Vin  
Bottom View  
4
Side View  
+Vout  
Trim  
-Vout  
+Vout  
-
3
Remote ON/OFF Remote ON/OFF  
10.2(0.4)  
10.16(0.4) 10.16(0.4)  
5.6(0.22 min.)  
25.4(1)  
H models(43~160Vin):  
25.4(1)  
10.16(0.4) 10.16(0.4)  
2.5(0.1)  
Pin-Out  
5
4
3
RSDW20H RDDW20H  
(Single output) (Dual output)  
Pin No.  
1
2
3
4
5
6
+Vin  
-Vin  
+Vin  
-Vin  
Side View  
Bottom View  
+Vout  
Trim  
-Vout  
+Vout  
-Vout  
Common  
1
2
6
Remote ON/OFF Remote ON/OFF  
5.08(0.2)  
15.24(0.6)  
10.2(0.4)  
5.1(0.2)  
5.6(0.22 min.)  
File Name:RSDW20,RDDW20-SPEC 2018-08-06  
20W 2"x1" Package Reliable Railway DC-DC Converter  
RSDW20 & RDDW20 series  
Derating Curve  
100  
80  
60  
Natural convection  
40  
20  
-40  
-20  
0
20  
40  
60  
73  
85  
105  
Ta ()  
EMC Suggestion Circuit  
F models(9~36Vin) and G models(18~75Vin):  
Comply to EN55032 conducted Class A without additional componets, required external componets to meet EN55032 conducted Class B  
emission are as below:  
L1  
L2  
+Vin  
-Vin  
+Vout  
-Vout  
+Vin  
-Vin  
+Vout  
-Vout  
C1  
RSDW20  
C2  
C3  
EN55032 Class B  
C2 C3  
Model No.  
C1  
L1  
L2  
220  
220  
220  
220  
μ
μ
μ
μ
F/50V KY  
F/50V KY  
F/50V KY  
F/50V KY  
1000pF/2KV 1000pF/2KV SHORT 1.2mH  
1000pF/2KV 1000pF/2KV SHORT 1.2mH  
1000pF/2KV 1000pF/2KV SHORT 1.2mH  
1000pF/2KV 1000pF/2KV SHORT 1.2mH  
1000pF/2KV 1000pF/2KV 0.15mH 1.2mH  
1000pF/2KV 1000pF/2KV 0.15mH 1.2mH  
1000pF/2KV 1000pF/2KV 0.15mH 1.2mH  
1000pF/2KV 1000pF/2KV 0.15mH 1.2mH  
RSDW20F-03  
RSDW20F-05  
RSDW20F-12  
RSDW20F-15  
RSDW20G-03  
RSDW20G-05  
RSDW20G-12  
RSDW20G-15  
220  
220  
220  
220  
μ
F/100V PW  
F/100V PW  
F/100V PW  
F/100V PW  
μ
μ
μ
Note: C1 is NIPPON-CHEMICON KY series or NICHICON PW series aluminum capacitor  
C2, C3 are ceramic capacitors  
Required external componets to meet EN55032 conducted Class A emission are as below:  
+Vin  
-Vin  
+Vout  
-Vout  
+Vin  
-Vin  
+Vout  
-Vout  
C1  
RDDW20  
EN55032 Class A  
Model No.  
C1  
10μ  
10μ  
10μ  
F/50V/MLCC 1210  
RDDW20F-05  
RDDW20F-12  
RDDW20F-15  
RDDW20G-05  
RDDW20G-12  
RDDW20G-15  
F/50V/MLCC 1210  
F/50V/MLCC 1210  
NC  
NC  
NC  
File Name:RSDW20,RDDW20-SPEC 2018-08-06  
20W 2"x1" Package Reliable Railway DC-DC Converter  
RSDW20 & RDDW20 series  
H models(43~160Vin):  
Comply to EN55032 conducted Class A without additional componets are as below:  
+Vin  
-Vin  
+Vout  
-Vout  
+Vin  
-Vin  
+Vout  
-Vout  
RSDW20  
RDDW20  
Required external componets to meet EN50121-3-2(EN55011 Class A conducted & Radiated Emission) are as below:  
+Vin  
-Vin  
+Vout  
-Vout  
+Vin  
-Vin  
+Vout  
-Vout  
RSDW20  
D1  
Model No.  
D1  
P6KE180A Littelfuse  
P6KE180A Littelfuse  
P6KE180A Littelfuse  
RSDW20H-05  
RSDW20H-12  
RSDW20H-15  
Installation Manual  
Please refer to : http://www.meanwell.com/manual.html  
File Name:RSDW20,RDDW20-SPEC 2018-08-06  

相关型号:

RSDW20G-05

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RSDW20G-12

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RSDW20G-15

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RSDW20H-05

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RSDW20H-12

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RSDW20H-15

20W 2x1 Package Reliable Railway DC-DC Converter
MEANWELL

RSDW20UW

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter
MEANWELL

RSDW20UW-05

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter
MEANWELL

RSDW20UW-12

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter
MEANWELL

RSDW20UW-15

8.5~160Vdc Ultra-wide Input Railway DC-DC Converter
MEANWELL

RSE-0505H2

2:1 Wide Input Range
RECOM

RSE-0505S

2:1 Wide Input Range
RECOM