SY100S331_10 [MICREL]

TRIPLE D FLIP-FLOP; 三重D触发器
SY100S331_10
型号: SY100S331_10
厂家: MICREL SEMICONDUCTOR    MICREL SEMICONDUCTOR
描述:

TRIPLE D FLIP-FLOP
三重D触发器

触发器
文件: 总6页 (文件大小:392K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1  
TRIPLE D  
FLIP-FLOP  
SY100S331  
FEATURES  
DESCRIPTION  
TheSY100S331offersthreeD-type,edge-triggeredmaster/  
slave flip-flops with true and complement outputs, designed  
for use in high-performance ECL systems. Each flip-flop is  
controlled by a common clock (CPc), as well as its own clock  
pulse (CPn). The resultant clock signal controlling the flip-flop  
is the logical OR operation of these two clock signals. Data  
entersthemasterwhenbothCPc andCPn areLOWandenters  
the slave on the rising edge of either CPc or CPn (or both).  
Additional control signals include Master Set (MS) and  
Master Reset (MR) inputs. Each flip-flop also has its own  
Direct Set (SDn) and Direct Clear (CDn) signals. The MR, MS,  
SDn and DCn signals override the clock signals. The inputs  
on this device have 75kΩ pull-down resistors.  
■ꢀ Max.ꢀtoggleꢀfrequencyꢀofꢀ800MHz  
■ꢀ Differentialꢀoutputs  
■ꢀ IEEꢀmin.ꢀofꢀ–80mA  
■ꢀ Industryꢀstandardꢀ100KꢀECLꢀlevels  
■ꢀ Extendedꢀsupplyꢀvoltageꢀoption:  
VEEꢀ=ꢀ–4.2Vꢀtoꢀ–5.5V  
■ꢀ Voltageꢀandꢀtemperatureꢀcompensationꢀforꢀimprovedꢀ  
noiseꢀimmunity  
■ꢀ Internalꢀ75kΩꢀinputꢀpull-downꢀresistors  
■ꢀ 150%ꢀfasterꢀthanꢀFairchild  
■ꢀ 40%ꢀlowerꢀpowerꢀthanꢀFairchild  
■ꢀ FunctionꢀandꢀpinoutꢀcompatibleꢀwithꢀFairchildꢀF100K  
■ꢀ Availableꢀinꢀ28-pinꢀPLCCꢀpackage  
BLOCKꢀDIAGRAM  
PINꢀNAMES  
Pinꢀ  
CP0 – CP2  
CPc  
Function  
Individual Clock Inputs  
Common Clock Input  
Data Inputs  
D0 – D2  
CD0 – CD2  
SDn  
Individual Direct Clear Inputs  
Individual Direct Set Inputs  
Master Reset Input  
Master Set Input  
MR  
MS  
Q0 – Q2  
Q0 – Q2  
VEES  
Data Outputs  
Complementary Data Outputs  
VEE Substrate  
VCCA  
VCCO for ECL Outputs  
Rev.: I  
Amendment: /0  
M9999-060910  
hbwhelp@micrel.com or (408) 955-1690  
1
Issue Date: June 2010  
SY100S331  
Micrel, Inc.  
PACKAGE/ORDERINGꢀINFORMATION  
OrderingꢀInformation  
Packageꢀ Operatingꢀꢀ  
Packageꢀ  
Markingꢀ  
Lead  
Finish  
PartꢀNumberꢀ  
Typeꢀ  
J28-1  
J28-1  
J28-1  
Rangeꢀ  
SY100S331JC  
Commercial  
Commercial  
Commercial  
SY100S331JC  
SY100S331JC  
Sn-Pb  
Sn-Pb  
SY100S331JCTR(1)  
SY100S331JZ(2)  
SY100S331JZ with  
Matte-Sn  
Pb-Free bar-line indicator  
SY100S331JZTR(1, 2)  
J28-1  
Commercial  
SY100S331JZ with  
Matte-Sn  
Pb-Free bar-line indicator  
SY100S331JY with  
Pb-Free bar-line indicator  
SY100S331JY(2)  
J28-1  
J28-1  
Matte-Sn  
Matte-Sn  
Industrial  
Industrial  
SY100S331JY with  
Pb-Free bar-line indicator  
SY100S331JYTR(1,2)  
28-PinꢀPLCCꢀ(J28-1)  
Notes:  
1. Tape and Reel.  
2. Pb-Free package is recommended for new designs.  
TRUTHꢀTABLES  
SynchronousꢀOperation(1)  
AsynchronousꢀOperation(1)  
Inputsꢀ  
Outputs  
Inputsꢀ  
Outputs  
MS  
MR  
MS  
MR  
Dnꢀ  
L
CPnꢀ  
CPc  
L
SDnꢀ  
DCn  
Qn  
L
Dnꢀ  
X
CPnꢀ  
X
CPc  
X
SDnꢀ  
DCn  
Qnꢀ(t+1)  
u
u
L
L
L
H
X
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
L
L
H
H
H
L
H
L
L
H
X
X
X
u
L
X
X
X
H
U
H
X
u
H
NOTE:  
L
Qn (t)  
Qn (t)  
Qn (t)  
1. H = High Voltage Level, L = Low Voltage Level, X = Don't Care, U =  
Undefined, t = Time before CP Positive Transition, t+1 = Time after CP  
Positive Transition, u = Low-to-High Transition  
X
X
X
H
NOTE:  
1. H = High Voltage Level, L = Low Voltage Level, X = Don't Care, U =  
Undefined, t = Time before CP Positive Transition, t+1 = Time after CP  
Positive Transition, u = Low-to-High Transition  
M9999-060910  
hbwhelp@micrel.com or (408) 955-1690  
2
ꢀ Symbolꢀ  
Parameterꢀ  
Max  
                                                                                                   
.
Min.ꢀ  
800  
Max.ꢀ  
Min.ꢀ  
800  
Max.ꢀ  
Min.ꢀꢀꢀꢀꢀꢀMax.ꢀꢀꢀꢀUnitꢀꢀꢀꢀꢀCondition  
SY100S331  
Micrel, Inc.  
DCꢀELECTRICALꢀCHARACTERISTICS  
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND  
ꢀ Symbolꢀ  
Parameterꢀ  
Min.ꢀ  
Typ.ꢀ  
Max.ꢀ  
200  
Unitꢀ  
µA  
Condition  
IIH  
Input HIGH Current, All Inputs  
Power Supply Current  
VIN = VIH (Max.)  
IEE  
–80  
–65  
–35  
mA  
Inputs Open  
ACꢀELECTRICALꢀCHARACTERISTICS  
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND  
TAꢀ=ꢀ-40°C  
Min.  
TAꢀ=ꢀ0°CꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀTAꢀ=ꢀ+25°CꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀTAꢀ=ꢀ+85°C  
800  
300  
fmax  
Toggle Frequency  
800  
300  
MHz  
ps  
700  
tPLH  
tPHL  
Propagation Delay  
300  
700  
300  
700  
700  
CPc to Output  
300  
tPLH  
tPHL  
Propagation Delay  
CPn to Output  
300  
300  
300  
300  
700  
800  
900  
900  
300  
300  
300  
300  
700  
800  
900  
900  
300  
300  
300  
300  
700  
800  
900  
900  
700  
800  
900  
900  
ps  
ps  
tPLH  
tPHL  
Propagation Delay  
CDn, SDn to Output  
300  
300  
300  
tPLH  
tPHL  
Propagation Delay  
MS, MR to Output  
ps  
ps  
ps  
tTLH  
tTHL  
Transition Time  
20% to 80%, 80% to 20%  
tS  
Set-up Time  
Dn  
400  
400  
500  
800  
400  
500  
800  
400  
500  
800  
CDn, SDn (Release Time) 500  
MS, MR (Release Time)  
800  
300  
ps  
ps  
tH  
Hold Time Dn  
300  
800  
300  
800  
300  
800  
tpw (H)  
Pulse Width HIGH  
CPn, CPc, DCn  
SDn, MR, MS  
800  
M9999-060910  
hbwhelp@micrel.com or (408) 955-1690  
3
SY100S331  
Micrel, Inc.  
TIMINGꢀDIAGRAMS  
PropagationꢀDelayꢀ(Clock)ꢀandꢀTransitionꢀTimes  
Note:  
VEE = –4.2V to –5.5V unless otherwise specified, VCC = VCCA = GND  
PropagationꢀDelayꢀ(SetsꢀandꢀResets)  
M9999-060910  
hbwhelp@micrel.com or (408) 955-1690  
4
SY100S331  
Micrel, Inc.  
TIMINGꢀDIAGRAMSꢀ  
DataꢀSetupꢀandꢀHoldꢀTime  
Notes:  
ts is the minimum time before the transition of the clock that information must be present at the data input.  
th is the minimum time after the transition of the clock that information must remain unchanged at the data input.  
M9999-060910  
hbwhelp@micrel.com or (408) 955-1690  
5
SY100S331  
Micrel, Inc.  
28-PINꢀPLCCꢀ(J28-1)  
MICREL,ꢀINC.ꢀ 2180ꢀFORTUNEꢀDRIVEꢀ SANꢀJOSE,ꢀCAꢀ 95131ꢀ USA  
t e l + 1 (408) 944-0800 f a x + 1 (408) 474-1000 w e b http://www.micrel.com  
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.  
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.  
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can  
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into  
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s  
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify  
Micrel for any damages resulting from such use or sale.  
© 2006 Micrel, Incorporated.  
M9999-060910  
hbwhelp@micrel.com or (408) 955-1690  
6

相关型号:

SY100S336

4-STAGE COUNTER/ SHIFT REGISTER
MICREL

SY100S336A

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336ADC

Counter/Shift Register
ETC

SY100S336AFC

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336AFCTR

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336AJC

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336AJCTR

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336AJZ

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336AJZTR

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336A_06

ENHANCED 4-STAGE COUNTER/SHIFT REGISTER
MICREL

SY100S336DC

Counter/Shift Register
ETC

SY100S336FC

4-STAGE COUNTER/ SHIFT REGISTER
MICREL