WRA4805ZD-1W5 [MICRODC]
1.5W, WIDE INPUT, ISOLATED®ULATED DUAL OUTPUT DC-DC CONVERTER; 1.5W ,宽电压输入,隔离章; ULATED双输出DC- DC转换器型号: | WRA4805ZD-1W5 |
厂家: | MICRODC POWER TECHNOLOGY CO., LTD |
描述: | 1.5W, WIDE INPUT, ISOLATED®ULATED DUAL OUTPUT DC-DC CONVERTER |
文件: | 总3页 (文件大小:674K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRA-ZD-1W5&WRB-ZD-1W5 Series
1.5W, WIDE INPUT, ISOLATED®ULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
SELECTION GUIDE
Input
Output
Current(mA)
Efficiency
(%,Typ)
Order code
Voltage(VDC)
No-load
Voltage
(VDC)
Nominal
24
Range
9-36
Max.*
40
Max.
Min.
(mA)(typ.)
WRA2405ZD-1W5
WRA2412ZD-1W5
WRA2415ZD-1W5
WRB2403ZD-1W5
WRB2405ZD-1W5
WRB2409ZD-1W5
WRB2412ZD-1W5
WRB2415ZD-1W5
WRA4805ZD-1W5
WRA4812ZD-1W5
WRA4815ZD-1W5
WRB4803ZD-1W5
WRB4805ZD-1W5
WRB4809ZD-1W5
WRB4812ZD-1W5
WRB4815ZD-1W5
16
16
16
16
16
16
16
16
8
±5
±12
±15
3.3
5
±150
±15
74
78
79
72
74
76
78
80
74
78
80
72
74
76
78
80
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
9-36
9-36
40
40
40
40
40
40
40
80
80
80
80
80
80
80
80
±63
±50
455
±6
±5
45
FEATURES
9-36
◆DIP24 package
9-36
300
30
◆Wide input voltage range(4:1)
◆Operating temperature: -40℃~ +85℃
◆1500VDC Input/Output isolation
◆Short circuit protection(automatic recovery)
◆Internal SMD construction
9-36
9
167
17
9-36
12
125
12
9-36
15
100
10
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
±5
±12
±15
3.3
5
±150
±63
±50
455
±15
±6
±5
45
8
8
◆No external component required
◆No heat sink required
8
8
300
30
8
9
167
17
◆Industry standard pinout
8
12
125
12
◆Five-sided shielding package
◆MTBF>1,000,000 hours
◆RoHS Compliance
8
15
100
10
* Input voltage over it may cause permanent damage to the device.
MODEL SELECTION
⑥
①
②
③
④
⑤
WRA 24 12 Z D -1W5
①Product Series ②Input Voltage
③Output Voltage ④Wide (4:1) Input Range
⑤DIP24 Package ⑥Rated Power
COMMON SPECIFICATIONS
Parameter
Test conditions
Min.
Typ.
Max.
Units
APPLICATIONS
Storage humidity
Operating temperature
Storage Temperature
Temp. rise at full load
Lead temperature
Cooling
95
85
%
℃
℃
℃
℃
The WRA_ZD-1W5&WRB_ZD-1W5 series
are specially designed for applications where
a wide range input voltage power supplies
are isolated from the input power supply in a
distributed power supply system on a circuit
board.
-40
-55
125
15
1.5mm from case for 10 seconds
300
Free air convection
Case material
Plastic(UL94-V0) or Stainless steel
These products apply to:
1) Where the voltage of the input power supply
is wide range (voltage range≤4:1);
Short circuit protection
MTBF
Continuous, automatic recovery
1000
15
K hours
g
Weight
2) Where isolation is necessary between input
and output (Isolation Voltage≤1500VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
ISOLATION SPECIFICATIONS
Parameter
Isolation voltage
Test conditions
Min.
Typ.
100
Max.
Units
MICRODC RESERVES THE COPYRIGHT
Tested for 1 minute and 1mA max
Test at 500VDC
1500
1000
VDC
MΩ
pF
Isolation resistance
Isolation capacitance
Input/Output, 100KHz/1V
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 3
WRA-ZD-1W5&WRB-ZD-1W5 Series
ISOLATION SPECIFICATIONS
TYPICAL CHARECTERISTICS
Parameter
Output power
Test conditions
Min.
0.15
Typ.
Max
Units
See above products program
Refer to recommended circuit
Refer to recommended circuit
From 10% to 100% load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
1.5
±3
W
%
Positive voltage accuracy
Negative voltage accuracy
Load regulation
Line regulation
±1
±3
±5
%
±0.5
±0.2
±2*
±0.75
±0.03
50
%
%
Temperature drift
Ripple**
%/℃
mVp-p
mVp-p
KHz
20
50
Noise**
20MHz Bandwidth
100
Switching frequency
100% load, input voltage range
300
* Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable”method. See detailed operation instructions at Testing of Power
Converter section, application notes.
RECOMMENDED CIRCUIT
APPLICATION NOTE
1) Requirement on output load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full
load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of
input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less
than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability
will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra
loading, or contact our company for other lower output power products.
2) Recommended Circuit
All the WRA_ZD-1W5&WRB_ZD-1W5 Series have been tested according to the following
recommended testing circuit before leaving factory. (See Figure 1).
If you want to further decrease the input/output ripple, you can increase capacitance properly or choose
capacitors with low ESR. However, the capacitance should not be too high, or may cause start-up
problem. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees (Table 1).If you want to use the products in high EMI, please
choose our metal packaged products (WRA_ZD-1W5 & WRB_ZD-1W5). General:
Cin:
24V&48V
10µF~47µF
Cout: 10µF/100mA
3) Input Current
When it is used in unregulated power supply, be sure that the fluctuating range of the power supply
and the rippled voltage do not exceed the module standard. Input current of power supply should afford the
startup current of this kind of DC/DC module. (See figure 2)
General: Ip ≤1.4*Iin-max
4) No parallel connection or plug and play
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3
WRA-ZD-1W5&WRB-ZD-1W5 Series
OUTLINE DIMENSIONS&FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT(TOP VIEW)
TUBE OUTLINE DIMENSIONS
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25℃, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this data sheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
RoHS COMPLIANT INFORMATION
Microdc Professional Power Module,Inc.
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C
for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte
Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are
backward compatible with Sn/Pb soldering systems.
Tel:0086-20-86000646 E-mail:tech@microdc.cn
Website:http://www.microdc.cn
Microdc Professional Power module,Inc.makes no representation that
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
future patent rights. Specifications are subject to change without notice.
©2010 Microdc Professional Power Module, Inc. Guangzhou
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has harmful chemical
substances through the registration, inspection and approval.
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 3
相关型号:
©2020 ICPDF网 联系我们和版权申明