WRB-YD -30W Series(2.16)
30W, WIDE INPUT, DIP PACKAGE,ISOLATED®ULATED SINGLE OUTPUT DC-DC CONVERTER
FEATURES
SELECTION GUIDE
◆Wide (2:1) Input Range
Input
Output
Current
◆Short Circuit Protection(automatic recovery)
◆1500VDC Isolation
Efficiency
Capacitance
Voltage(VDC)
Voltage
(VDC)
Order code
(%.Typ.)
(max,UF.)
(%,Typ).
Nominal
Range
◆Operating Temperature: -40℃~﹢85℃
◆Six sided metal shielding
◆Over Voltage protection
WRB1203YD-30W
WRB1205YD-30W
WRB1212YD-30W
WRB1215YD-30W
WRB1224YD-30W
WRB2403YD-30W
WRB2405YD-30W
WRB2412YD-30W
WRB2415YD-30W
WRB2424YD-30W
WRB4803YD-30W
WRB4805YD-30W
WRB4812YD-30W
WRB4815YD-30W
WRB4824YD-30W*
12
12
12
12
12
24
24
24
24
24
48
48
48
48
48
9-18
9-18
3.3
5
6000
6000
2500
2000
1250
6000
6000
2500
2000
1250
6000
6000
2500
2000
1250
85
88
83
82
81
81
88
81
83
85
83
81
81
84
81
19000
10300
3340
1100
900
9-18
12
15
24
3.3
5
9-18
◆Internal SMD construction
◆RoHS Compliance
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
19500
10200
3300
1100
900
12
15
24
3.3
5
◆Industry Standard Pin Out
◆MTBF>1000Khours
19500
10200
3300
1100
900
MODEL SELECTION
①
②
③
④
⑤
⑥
WRB 24 15 Y D -30W
12
15
24
①Product Series ②Input Voltage
③Output Voltage ④Wide (2:1) Input Range
⑤DIP Package Style
*Designing…
⑥Rated Power
COMMON SPECIFICATIONS
Parameter
Storage humidity
Operating temperature
Storage temperature
Lead temperature
Case material
Conditions
Min. Typ. Max. Units
APPLICATIONS
5
95
85
%
℃
℃
℃
The WRB_YD-30W Series are specially
designed for applications where a wide range
input voltage power supplies are isolated from
the input power supply in a distributed power
supply system on a circuitboard.
-40
-55
105
300
1.5mm from case for 10 seconds
Steel,nickel coated, copper
These productsapply to:
Tested for1 minute and 1mA max
Isolation voltage
Isolation resistance
Isolation Capacitance
MTBF
1500
1000
1000
1000
45
VDC
MΩ
1) Where the voltage of the input power
supply is wide range (Voltage range≤2:1);
2) Where isolation is necessary between
input and output
100KHz/1V
pF
K hours
g
Weight
(Isolation voltage≤1500VDC);
3) Where the regulation of the Output voltage
and the output ripple noise are demanded.
INPUT SPECIFICATIONS
Parameter
Start voltage/Under
voltage shutdown
Conditions
Min.
Typ. Max. Units
12V input models
24V input models
48V input models
8.6/8.1
17.5/16
34/32
8.8/8.
17.8/1
35/33
20
9/8.5
18/17
36/34
VDC
VDC
VDC
MS
Start up time
Input filter
Pi
Method of Remote
On
Off
3.5-40VDC or open circuit
0-1.2VDC
MICRODC reserves the copyright
(Reference point:GND)
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 3
WRB-YD -30W Series(2.16)
TEMPERATURE CHARACTERISTICS
TYPICAL CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Temperature Derating Graph
Output voltage accuracy
Refer to recommended circuit
±1
±3
%
Over load protection
Output Short Circuit
Load regulation
Input voltage range
Input voltage range
120
130
150
%
Hiccup,automatics recovery
From 10% to 100% load
±0.5
±1
%
Trim
±10%V0
VDC
%/℃
%
Temperature drift (Vout)
Line regulation
0.02
Input voltage from low to high
Tested under 20MHz brand
25% load change
±0.2
75
±0.5
150
300
±5
Ripple&Noise
50
mV
Transient recovery time
Transient peak deviation
200
±3
us
±2
%
3.3V
5V
3.63
5.5
4.29
6.5
VDC
VDC
VDC
VDC
VDC
RECOMMENDED CIRCUIT
Over voltage protection
12V
15V
24V
13.2
16.5
26.4
15.6
19.5
31.2
Output Graph
Note:
1. All specifications are measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
2. The CTRL control pin voltage is referenced to GND.
3. Typical efficiency value at nominal input voltage and full load.
4. Capacitor MAX load tested at nominal input voltage and constant resistive load.
5. Refer to the diagram of Output Voltage trim up/down for trim applications.
6. The products cannot be used in parallel and in plug and play.
In order to abtain better performance for the DC/DC
models.it’s recommended that use input and output
filters as Fig.1 shown.
DERATING&EFFICIENCY CURVE
Requirement on output load
L:12uH
C:100uF/100V
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load.If the actual
load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
OUTPUT VOLTAGE TRIM
Output Graph
Curve of Efficiency VS input Voltage WRB2424YD-30W
Curve of Efficiency VS output load WRB2424YD-30W
No parallel connection or plug and play
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3
WRB-YD -30W Series(2.16)
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
RECOMMENDED FOOTPRINT
Top view grid:2.54mm(0.1inch)
diameter:1.50mm(0.059inch)
Note:
Unit:mm[inch]
Pin diameter:1.00mm[0.039inch]
Pin diameter tolerances:±0.05mm[±0.002inch]
General tolerances:±0.25mm[±0.010inch]
TUBE OUTLINE DIMENSIONS
FOOTPRINT DETAILS
Pin
1
Single
Vin
2
GND
Ctrl
3
4
Trim
0V
5
6
+Vo
Note: The CTRL control pin voltage is referenced to GND
When the environment temperature is higher than
71℃, the product output power should be less
then 60% of the rated power.
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening
output pin (0V) to use as single output.
Note:
Unit :mm[inch]
General tolerances:±0.250mm[±0.010inch]
Note:
1. The CTRL control pin voltage is referenced to GND.
2. Typical efficiency value at nominal input voltage and full load.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Capacitor MAX load tested at nominal input voltage and constant resistive load.
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 3
相关型号:
©2020 ICPDF网 联系我们和版权申明