WRB2412YMD-10W [MICRODC]
2:1 WIDE INPUT,ISOLATED®ULATED Single Output DC/DC Converter; 2 : 1宽电压输入,隔离章; ULATED单输出DC / DC转换器型号: | WRB2412YMD-10W |
厂家: | MICRODC POWER TECHNOLOGY CO., LTD |
描述: | 2:1 WIDE INPUT,ISOLATED®ULATED Single Output DC/DC Converter |
文件: | 总3页 (文件大小:829K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRA-YMD-10W&WRB-YMD-10W Series
2:1 WIDE INPUT,ISOLATED®ULATED Dual/Single Output DC/DC Converter
SELECTION GUIDE
Input
Output
Current(MA)
Efficiency
(%,Typ)
order code
Voltage
(VDC)
Voltage(VDC)
Range
Nominal
Max*
Max
Min
WRA0505YMD-10W
WRA0509YMD-10W
WRA0512YMD-10W
WRA0515YMD-10W
WRB0505YMD-10W
WRB0509YMD-10W
WRB0512YMD-10W
WRB0515YMD-10W
WRA1205YMD-10W
WRA1209YMD-10W
WRA1212YMD-10W
WRA1215YMD-10W
WRB1203YMD-10W
WRB1205YMD-10W
WRB1209YMD-10W
WRB1212YMD-10W
WRB1215YMD-10W
WRB1224YMD-10W
WRA2405YMD-10W
WRA2409YMD-10W
WRA2412YMD-10W
WRA2415YMD-10W
WRB2403YMD-10W
WRB2405YMD-10W
WRB2409YMD-10W
WRB2412YMD-10W
WRB2415YMD-10W
WRA4805YMD-10W
WRA4809YMD-10W
WRA4812YMD-10W
WRA4815YMD-10W
WRB4803YMD-10W
WRB4805YMD-10W
WRB4809YMD-10W
WRB4812YMD-10W
WRB4815YMD-10W
5
4.5-9.0
4.5-9.0
11
11
11
11
11
11
11
11
20
20
20
20
20
20
20
20
20
20
40
40
40
40
40
40
40
40
40
80
80
80
80
80
80
80
80
80
±1000
±556
±416
±333
2000
1111
833
±100
±56
±42
±33
200
111
83
±5
±9
±12
±15
5
75
76
80
82
76
78
80
82
79
84
82
84
79
79
81
82
84
82
81
79
84
86
78
80
78
84
86
80
80
84
85
78
80
80
84
86
5
5
4.5-9.0
5
4.5-9.0
FEATURES
◆RoHS compliant
5
4.5-9.0
5
4.5-9.0
9
5
4.5-9.0
12
15
±5
±9
±12
±15
3.3
5
◆Efficiency up to 86%
5
4.5-9.0
666
66
◆DIP Package
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
9.0-18.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
18.0-36.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
36.0-72.0
±1000
±556
±416
±333
2500
2000
1111
833
±100
±56
±42
±33
250
200
111
83
◆Wide temperature performance at full 10 Watt
load,-40°C to 85°C
◆UL 94V-0 package material
◆No heatsink required
9
12
15
24
±5
±9
±12
±15
3.3
5
◆ Industry standard pinout
◆ I/O Isolation 1500VDC
◆ Short Circuit Protection(automatic recovery)
◆ Metal shielding package
◆ MTBF>1000000 hours
666
66
416
42
±1000
±556
±416
±333
2500
2000
1111
833
±100
±56
±42
±33
250
200
111
83
9
12
15
±5
±9
±12
±15
3.3
5
MODEL SELECTION
666
66
①
②
③
④
⑤
⑥
⑦
WRB 24 05 Y M D -10W
±1000
±556
±416
±333
2500
2000
1111
833
±100
±56
±42
±33
250
200
111
83
①Product Series
③Output Voltage
⑤Metal Shield
⑦Rated Power
②Input Voltage
④Wide (2:1) Input Range
⑥DIP Package Style
9
DESCRIPTION
12
15
The WRA_YMD-10W & WRB_YMD-10W series are
specially designed for applications where a group of polar
power supplies are isolated from the input power supply in
a distributed power supply system on a circuit board.
These products apply to:
666
66
*Input voltage can't exceed this value,or will cause the permanent damage.
OUTPUT SPECIFICATIONS
1) where the voltage of the input power supply is wide
range (voltage range ≤2:1);
Parameter
Output power
Test conditions
Refer to products program
Refer to recommended circuit
Refer to recommended circuit
From 10% to 100% full load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
Min.
1
Typ.
Max.
10
Units
W
2) where isolation is necessary between input and output
(isolation voltage ≤1500VDC);
Positive voltage accuracy
Negative voltage accuracy
Load regulation
±1.0
±3.0
±0.5
±0.2
±3.0
±5.0
±1.0*
±0.5
±0.03
50
%
3) where the regulation of the output voltage and the
output ripple noise are demanded.
%
%
Line regulation(at full load)
Temperature drift(Vout)
Output Ripple**
%
%/°C
MV p-p
MV p-p
Khz
20
85
Output Noise**
20MHz Bandwidth
150
MICRODC RESERVES THE COPYRIGHT
Switching frequency
100% Full load,input voltage range
300
*
Dual output models unbalanced load (25/100%):±5%Max
* *Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 3
WRA-YMD-10W&WRB-YMD-10W Series
TYPICAL CHARACTERISTICS
TEMPERATURE CHARACTERISTICS
Temperature Derating Graph
Parameter
Conditions
Min.
Typ.
Max.
Units
Storage humidity range
NO-load power consumption
Operating temperature
Storage temperature
Lead temperature
Temp.rise at full load
Cooling
95
%
MW
°C
500
-40
-55
85
125
300
°C
1.5mm from case for 10 seconds
°C
40
°C
Free air convection
Plastic(UL94-V0)
Case material
Short circuit protection*
Case material
Continuous,automatic recovery
Aluminium alloy
MTBF
1000
K hours
g
Weight
23.5
*Supply voltage must be discontinued at the end of short circuit duration.
RECOMMENDED CIRCUIT
ISOLATION SPECIFICATIONS
OUTPUT Graph
Parameter
Test conditions
Min.
Typ.
Max.
Units
Flash tested for 1 minute and 1mA max
Test at Viso=500VDC
Isolation test voltage
Isolation resistance
Isolation capacitance
1500
1000
VDC
MΩ
pF
Input/Output
100
APPLICATION NOTE
1) Requirement on output load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely full
load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified range of
input voltage is not exceeded, the minimum output load no less than 10% load. If the actual load is less
than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability
will reduce greatly. If the actual output power is very small, please add an appropriate resistor as extra
loading, or contact our company for other lower output power products.
2) Recommended Circuit
All the WRA_YMD-10W & WRB_YMD-10W Series have been tested according to the following
recommended testing circuit before leaving factory. This series should be tested under load. Never be
tested under no load (see Figure 1).
If you want to further decrease the input/output ripple,you can increase capacitance properly or
choose capacitors with low ESR. However, the capacitance of the output filter capacitor must be proper.
If the capacitance is too big, a startup problem might arise. For every channel of output,provided the safe
and reliable operation is ensured,the greatest capacitance of its filter capacitor sees (Table 1). General:
Cin: 5V&12V
24V&48V
100μF
10μF-47μF
Cout: 10PF/100mA
3) Input current
When it is used in unregulated power supply,be sure that the fluctuating range of the power supply
and the rippled voltage do not exceed the module standard.Input current of power supply should afford
the startup current of this kind of DC/DC module (Figure 2).
General: Ip≤1.4*Iin-max
EXTERNAL CAPACITOR TABLE (TABLE 1)
Single Vout
Cout
(μF)
2200
1000
470
Dual Vout
Cout
(μF)
680
330
220
_
4) No parallel connection or plug and play
(VDC)
3.3
5
(VDC)
±5
±12
±15
_
12
15
330
24
220
_
_
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 2 of 3
WRA-YMD-10W&WRB-YMD-10W Series
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
DUAL OUTPUT
SINGLE OUTPUT
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT
Top view,grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
FOOTPRINT DETAILS
TUBE OUTLINE DIMENSIONS
Pin
1
Single
GND
Vin
Dual
GND
Vin
2
3
+Vo
+Vo
4
NC
COM
-Vo
5
0V
6*
CTRL*
CTRL*
NC:No connection
*CTRL:CTRL pin can be added according to customers' need
When the environment temperature is higher than 71℃, the
product output power should be less then 60% of the rated
power.
Note:
Unit :mm[inch]
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening output pin (0V)
to use as single output.
General tolerances:±0.50mm[±0.020inch]
L=230mm[9.055inch] Tube Quantity: 7pcs
Note:
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 3 of 3
相关型号: