ZL50409  
Managed 9FE Layer-2 Ethernet Switch  
Data Sheet  
August 2006  
Zarlink Features  
Integrated Single-Chip 10/100 Mbps Ethernet  
Ordering Information  
Switch  
Eight 10/100 Mbps auto-negotiating Fast  
Ethernet (FE) ports with RMII, MII, GPSI,  
Reverse MII & Reverse GPSI interface options  
One 10/100 Mbps auto-negotiating port with  
MII interface option, that can be used as a  
WAN uplink or as a 9th port  
ZL50409GDC  
208-Ball LBGA  
ZL50409GDG2 208-Ball LBGA**  
**Pb Free Tin/Silver/Copper  
-40°C to +85°C  
a 10/100 Mbps Fast Ethernet (FE) CPU port  
with Reverse MII interface option  
Built-in reset logic triggered by system  
malfunction  
Built-In Self Test for internal SRAM  
IEEE-1149.1 (JTAG) test port  
Embedded 2.0 Mbits (256 KBytes) internal  
memory for control databases and frame data  
buffer  
Supports jumbo frames up to 4 KBytes  
L2 Switching  
CPU access supports the following interface  
L2 switching  
options:  
MAC address self learning, up to 4 K MAC  
8/16-bit ISA interface  
Serial interface with MII port; recommended  
for light management  
Serial interface in lightly managed mode, or in  
unmanaged mode with optional I2C EEPROM  
interface  
addresses  
MAC address table supports unicast and  
multicast MAC address and IP multicast  
address learning  
Supports IP Multicast with IGMP snooping, up to  
4 K IP Multicast groups  
Ethernet IEEE 802.3x flow control for full duplex  
ports, back pressure flow control for half duplex  
ports  
8/16-bit  
or  
Serial  
C
P
ZL50409  
U
MII  
MII  
10/100  
PHY  
9-Port 10/100M  
Ethernet Switch  
EEPROM  
RMII / MII / GPSI  
Quad  
Quad  
10/100  
PHY  
10/100  
PHY  
Figure 1 - System Block Diagram  
1
Zarlink Semiconductor Inc.  
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.  
Copyright 2003-2006, Zarlink Semiconductor Inc. All Rights Reserved.  
ZL50409  
Data Sheet  
Supports the following spanning standards  
IEEE 802.1D spanning tree  
IEEE 802.1w rapid spanning tree  
Supports Ethernet multicasting and broadcasting and flooding control  
VLAN Support Features  
Supports the following VLAN standards  
port-based VLAN  
IEEE 802.1Q tag-based VLAN, up to 4 K VLANs  
Supports both shared VLAN learning (SVL) and independent VLAN learning (IVL) of MAC addresses  
Limited support for VLAN stacking (“Q-in-Q”)  
Classification and Security  
Search engine classification  
Classifies packets based on single field  
-
-
-
-
Source and destination L4 logical ports, or  
TOS/DS, or  
VLAN (IEEE 802.1p), or  
Physical port  
Assigns a transmission priority and drop precedence  
Packet filtering and security  
Static address filtering for source and/or destination MAC addresses  
Static MAC address not subject to aging  
Secure mode freezes MAC address learning (each port may independently use this mode)  
IEEE 802.1x access control  
Port-based priority: VLAN priority in a tagged frame can be overwritten by the priority of port VLAN ID  
Traffic Management  
Two (2) transmission classes for FE ports and four (4) transmission classes for uplink port  
Scheduling using weighted fair queuing (WFQ) or strict priority (SP) discipline  
At egress, per-queue weighted random early discard (WRED) with 2 drop precedence levels  
Configurable WRED thresholds  
For FE ports, supports ingress and egress rate control  
Bandwidth rationing, Bandwidth on demand, SLA (Service Level Agreement)  
Granularity of rate regulation to 16 Kbps  
Ingress rate regulated using WRED, with 2 drop precedence levels, or flow control  
Output traffic regulation per class available on uplink port  
Fully supports Differentiated Services' Expedited and Assured Forwarding (EF and AF) per-hop behaviours  
Intelligent buffer management  
Achieves high buffer utilization while ensuring fairness among traffic classes and ports  
Buffer reservations per class and per source port  
Failover Features  
Rapid link failure detection using hardware-generated heartbeat packets  
link failover in less than 50 ms  
Supports concentration mode  
2
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Supports IEEE 802.3ad link aggregation  
Eight (8) groups of up to 8 ports per group  
Supports load sharing among trunk ports based on:  
-
-
Source port  
Source and/or destination MAC address  
Traffic Mirroring  
Physical port based (RMII enabled ports only)  
Source or destination MAC address based  
MAC address pair based  
Supports module hot swap on all ports  
Network Management Support  
Built-in RMON MIB counters  
Description  
The ZL50409 is a low density, low cost, high performance, non-blocking Ethernet switch chip. A single chip  
provides 8 ports at 10/100 Mbps, 1 uplink port at 10/100 Mbps, and a CPU interface for managed, lightly managed  
and unmanaged switch applications. The chip supports up to 4 K MAC addresses and up to 4 K tagged-based  
Virtual LANs (VLANs).  
With strict priority and/or WFQ transmission scheduling and WRED dropping schemes, the ZL50409 provides  
powerful QoS functions for various multimedia and mission-critical applications. The chip provides 2 transmission  
priorities (4 priorities for uplink port) and 2 levels of dropping precedence. Each packet is assigned a transmission  
priority and dropping precedence based on the VLAN priority field in a VLAN tagged frame, or the DS/TOS field, or  
the UDP/TCP logical port fields in IP packets. The ZL50409 recognizes a total of 16 UDP/TCP logical ports, 8  
hard-wired and 8 programmable (including one programmable range).  
The ZL50409 provides the ability to monitor a link, detect a simple link failure, and provide notification of the failure  
to the CPU. The CPU can then failover that link to an alternate link.  
The ZL50409 supports up to 8 groups of port trunking/load sharing. Each group can contain up to 8 ports. Port  
trunking/load sharing can be used to group ports between interlinked switches to increase the effective network  
bandwidth.  
In half-duplex mode, all ports support backpressure flow control, to minimize the risk of losing data during long  
activity bursts. In full-duplex mode, IEEE 802.3x flow control is provided. The ZL50409 also supports a per-system  
option to enable flow control for best effort frames, even on QoS-enabled ports.  
Statistical information for SNMP and the Remote Monitoring Management Information Base (RMON MIB) are  
collected independently for all ports. Access to these statistical counters/registers is provided via the CPU interface.  
SNMP Management frames can be received and transmitted via the CPU interface, creating a complete network  
management solution.  
The ZL50409 is fabricated using 0.18 micron technology. The ZL50409 is packaged in a 208-pin Ball Grid Array  
package.  
3
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Changes Summary  
July 2003  
Initial Release  
November 2003  
Clarified IP Multicast support is up to 4K groups, as it wasn’t mentioned in the data sheets  
Updated Ball Signal Description Table (1.3, “Ball Signal Descriptions“ on page 14):  
clarified the ball signal I/O description for Mn_TXCLK & Mn_RXCLK showing these signals are either  
inputs OR outputs  
clarified that M9_MTXCLK is an input only  
Updated 1.4, “Signal Mapping and Internal pull-up/Down Configuration“ on page 19 to indicate operation of  
the internal pull-up/down resistors in different modes  
Clarified 10.1.3, “MMAC Reference Clock (REF_CLK) Speed Requirement“ on page 52 on usage of  
REF_CLK  
Clarified PVMODE register bit description for bits [2] & [5]  
Updated ECR4Pn register description as port 9 (uplink) operates differently than the RMAC ports for MII  
bi-directional clocking (bits [1:0])  
2
I C address mapping was corrected for QOSCn registers  
Added Maximum Junction Temperature to 13.1, “Absolute Maximum Ratings“ on page 126  
Updated I/O voltage levels to use TTL spec values rather than % of Vcc (13.2, “DC Electrical  
Characteristics“ on page 126)  
February 2004  
Added the following to the Feature List:  
4 K jumbo frames  
IEEE 802.3ad support  
Reverse MII/GPSI  
Added section on PHY addresses (2.2.4, “PHY Addresses“ on page 27)  
Clarified that they are hard-coded  
Fixed error in DS on sending Ethernet Frames via 8/16-bit or serial interface.  
The Status Bytes is sent before the frame, for both Tx and Rx  
Added more cross-references to available AppNotes  
Added section on Stacked VLAN (Q-in-Q) (5.9.3, “VLAN Stacking (Q-in-Q)“ on page 42) and IP Multicast  
Switching (5.10, “IP Multicast Switching“ on page 43) since they weren’t really discussed in the DS  
Added more clock descriptions to 10.0, “Clocks“ on page 52  
INT_MASK and INTP_MASK registers should state that the default register value is 0x00  
August 2004  
Added section Changes Summary to document  
Added section on SCL clock generation (10.2.2, “SCL“ on page 53)  
Interrupt Register was incorrectly identified as read only, should be read/write  
Clarified that only bit [7] is not self-clearing  
Updated CPU timing diagrams to clarify timing (13.4, “AC Characteristics and Timing“ on page 128)  
November 2004  
Added section 1.6, “Default Switch Configuration and Initialization Sequence“ on page 23  
Updated CPU timing diagrams to clarify P_A timing (13.4, “AC Characteristics and Timing“ on page 128)  
4
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
January 2005  
Removed reference to direct register INDEX_REG1 (address 0x1) from SSI diagrams, as not applicable  
June 2005  
Clarified that port mirroring is only available if the source & destination ports are in RMII mode  
Updated PVMODE bit [5] to reflect the proper MAC address range: 01-80-C2-00-00-00~F  
Clarified DATAOUT output can be open-drain or totem-pole based on debounce selection via bootstrap  
TSTOUT[0]  
Added power sequencing recommendation (1.7, “Power Sequencing“ on page 25)  
Added Reverse MII/GPSI timing characteristics (13.4.10, “Reverse General Purpose Serial Interface  
(RvGPSI)“ on page 137 and 13.4.11, “MII Management Data Interface (MDIO/MDC)“ on page 138)  
Clarified that counter “DelayExceededDiscards” is not applicable for the ZL50409 (11.0, “Hardware Statistics  
Counters“ on page 53)  
December 2005  
Clarified that TRST signal should be externally tied to GND via weak resistor, as per JTAG standard (1.3,  
“Ball Signal Descriptions“ on page 14)  
Added more text to section 2.8, “JTAG“ on page 28  
Clarified counter definitions (11.0, “Hardware Statistics Counters“ on page 53)  
Added more explaination to VLAN ID Hashing feature: register FEN, bit [3]  
Removed definition for SE_OPMODE bit[5] (ARP report control), as this feature was not implemented and  
this bit was mistakenly left in the register definition.  
April 2006  
Added Pb-free order code (ZL50409GDG2)  
Added section on multicast MAC address learning/switching (5.11, “L2 Multicast Switching“ on page 43)  
since it wasn’t really discussed in the DS  
Clarified registers UCC, MCC & MCCTH  
Renamed register UCC (now PCC), as name was misleading  
Updated timing to CPU RvMII, as min. output delay should have been 0 ns  
July 2006  
Added typical values to power numbers in “Recommended Operating Conditions” table.  
Updated RM6 “CPU_MII_TXEN Output Delay Time” & RM7 “CPU_MII_TXD[3:0] Output Delay Time” max. to  
5 ns (old 14 ns)  
5
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
July 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
November 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
February 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
August 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
November 2004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
January 2005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
June 2005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
December 2005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
April 2006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
1.0 BGA and Ball Signal Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
1.1 BGA Views (Top-View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
1.2 Power and Ground Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
1.3 Ball Signal Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
1.4 Signal Mapping and Internal pull-up/Down Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
1.5 Bootstrap Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
1.5.1 Recommended Default Bootstrap Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
1.6 Default Switch Configuration and Initialization Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
1.7 Power Sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
2.0 Block Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  
2.1 Internal Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
2.2 MAC Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
2.2.1 RMII MAC Module (RMAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
2.2.1.1 GPSI (7WS) Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
2.2.2 CPU MAC Module (CMAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
2.2.3 MII MAC Module (MMAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
2.2.4 PHY Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
2.3 Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
2.4 Frame Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
2.5 Search Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
2.6 Heartbeat Packet Generation and Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
2.7 Timeout Reset Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
2.8 JTAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
2.8.1 Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
2.8.2 Test Access Port (TAP) Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
2.8.3 Boundary Scan Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
3.0 Management and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  
3.1 Register Configuration, Frame Transmission and Frame Reception . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32  
3.1.1 Register Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32  
3.1.2 Rx/Tx of Standard Ethernet Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33  
3.1.3 Control Frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34  
3.2 I2C Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34  
3.2.1 Start Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.2.2 Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.2.3 Data Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.2.4 Acknowledgment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.2.5 Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.2.6 Stop Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.3 Synchronous Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35  
3.3.1 Write Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
3.3.2 Read Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
4.0 Data Forwarding Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
4.1 Unicast Data Frame Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
6
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
4.2 Multicast Data Frame Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
4.3 Frame Forwarding To and From CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
5.0 Search Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
5.1 Search Engine Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
5.2 Basic Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
5.3 Search, Learning and Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
5.3.1 MAC Search. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
5.3.2 Learning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
5.3.3 Aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
5.4 MAC Address Filtering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
5.5 Protocol Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40  
5.6 Logical Port Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40  
5.7 Quality of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40  
5.8 Priority Classification Rule. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41  
5.9 Port and Tag Based VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41  
5.9.1 Port-Based VLAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41  
5.9.2 Tag-Based VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
5.9.3 VLAN Stacking (Q-in-Q). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
5.10 IP Multicast Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
5.11 L2 Multicast Switching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
6.0 Frame Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
6.1 Data Forwarding Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
6.2 Frame Engine Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
6.2.1 FCB Manager. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
6.2.2 Rx Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
6.2.3 RxDMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
6.2.4 TxQ Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
6.2.5 Port Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
6.2.6 TxDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
7.0 Quality of Service and Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
7.1 Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
7.2 Two QoS Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
7.2.1 Strict Priority. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
7.2.2 Weighted Fair Queuing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
7.3 WRED Drop Threshold Management Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
7.4 Shaper. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
7.5 Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47  
7.6 Buffer Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47  
7.6.1 Dropping When Buffers Are Scarce. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48  
7.7 Flow Control Basics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48  
7.7.1 Unicast Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49  
7.7.2 Multicast Flow Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49  
7.8 Mapping to IETF Diffserv Classes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49  
7.9 Failover Backplane Feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
8.0 Port Trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
8.1 Features and Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
8.2 Unicast Packet Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
8.3 Multicast Packet Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51  
9.0 Traffic Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51  
9.1 Mirroring Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51  
9.2 Using port mirroring for loop back . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51  
7
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
10.0 Clocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
10.1 Clock Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
10.1.1 System Clock (SCLK) Speed Requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
10.1.2 RMAC Reference Clock (M_CLK) Speed Requirement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
10.1.3 MMAC Reference Clock (REF_CLK) Speed Requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
10.1.4 JTAG Test Clock (TCK) Speed Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
10.2 Clock Generation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
10.2.1 MDC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
10.2.2 SCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
10.2.3 Ethernet Interface Clocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
11.0 Hardware Statistics Counters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
11.1 Hardware Statistics Counters List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
11.2 IEEE 802.3 HUB Management (RFC 1516) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
11.2.1 Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
11.2.1.1 PortReadableFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
11.2.1.2 PortReadableOctets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54  
11.2.1.3 PortFCSErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54  
11.2.1.4 PortAlignmentErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
11.2.1.5 PortFrameTooLongs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
11.2.1.6 PortShortEvents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55  
11.2.1.7 PortRunts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56  
11.2.1.8 PortCollisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56  
11.2.1.9 PortLateEvents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56  
11.2.1.10 PortVeryLongEvents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56  
11.2.1.11 PortDataRateMisatches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.2.1.12 PortAutoPartitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.2.1.13 PortTotalErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3 IEEE 802.1 Bridge Management (RFC 1286) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3.1 Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3.1.1 PortDelayExceededDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3.1.2 PortMtuExceededDiscards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3.1.3 PortInFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3.1.4 PortOutFrames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.3.1.5 PortInDiscards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57  
11.4 RMON – Ethernet Statistic Group (RFC 1757) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
11.4.1 Event Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
11.4.1.1 DropEvents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
11.4.1.2 Octets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
11.4.1.3 Pkts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
11.4.1.4 BroadcastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58  
11.4.1.5 MulticastPkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
11.4.1.6 CRCAlignErrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
11.4.1.7 UndersizePkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
11.4.1.8 OversizePkts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
11.4.1.9 Fragments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  
11.4.1.10 Jabbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60  
11.4.1.11 Collisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61  
11.4.1.12 Packet Count for Different Size Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61  
11.5 Miscellaneous Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61  
12.0 Register Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62  
12.1 ZL50409 Register Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62  
12.2 Directly Accessed Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69  
8
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
12.3 Indirectly Accessed Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73  
12.3.1 (Group 0 Address) MAC Ports Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73  
12.3.1.1 ECR1Pn: Port n Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73  
12.3.1.2 ECR2Pn: Port n Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75  
12.3.1.3 ECR3Pn: Port n Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77  
12.3.1.4 ECR4Pn: Port n Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77  
12.3.1.5 BUF_LIMIT – Frame Buffer Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79  
12.3.1.6 FCC – Flow Control Grant Period. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79  
12.3.2 (Group 1 Address) VLAN Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80  
12.3.2.1 AVTCL – VLAN Type Code Register Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80  
12.3.2.2 AVTCH – VLAN Type Code Register High. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80  
12.3.2.3 PVMAP00_0 – Port 0 Configuration Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80  
12.3.2.4 PVMAP00_1 – Port 0 Configuration Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80  
12.3.2.5 PVMAP00_3 – Port 0 Configuration Register 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81  
12.3.2.6 PVMAPnn_0,1,3 – Ports 1~9 Configuration Registers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82  
12.3.2.7 PVMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82  
12.3.3 (Group 2 Address) Port Trunking Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83  
12.3.3.1 TRUNKn– Trunk Group 0~7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83  
12.3.3.2 TRUNKn_HASH10 – Trunk group n hash result 1/0 destination port number . . . . . . . . . . . 84  
12.3.3.3 TRUNKn_HASH32 – Trunk group n hash result 3/2 destination port number . . . . . . . . . . . 84  
12.3.3.4 TRUNKn_HASH54 – Trunk group n hash result 5/4 destination port number . . . . . . . . . . . 84  
12.3.3.5 TRUNKn_HASH76 – Trunk group n hash result 7/6 destination port number . . . . . . . . . . . 84  
Multicast Hash Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84  
12.3.3.6 MULTICAST_HASHn-0 – Multicast hash result 0~7 mask byte 0 . . . . . . . . . . . . . . . . . . . . 85  
12.3.3.7 MULTICAST_HASHn-1 – Multicast hash result 0~7 mask byte 1 . . . . . . . . . . . . . . . . . . . . 85  
12.3.4 (Group 3 Address) CPU Port Configuration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
12.3.4.1 MAC0 – CPU MAC address byte 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
12.3.4.2 MAC1 – CPU MAC address byte 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
12.3.4.3 MAC2 – CPU MAC address byte 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
12.3.4.4 MAC3 – CPU MAC address byte 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
12.3.4.5 MAC4 – CPU MAC address byte 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
12.3.4.6 MAC5 – CPU MAC address byte 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87  
12.3.4.7 INT_MASK0 – Interrupt Mask. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87  
12.3.4.8 INTP_MASK0 – Interrupt Mask for MAC Port 0,1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87  
12.3.4.9 INTP_MASKn – Interrupt Mask for MAC Ports 2~9 Registers . . . . . . . . . . . . . . . . . . . . . . . 88  
12.3.4.10 RQS – Receive Queue Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88  
12.3.4.11 RQSS – Receive Queue Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88  
12.3.4.12 MAC01 – Increment MAC port 0,1 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89  
12.3.4.13 MAC23 – Increment MAC port 2,3 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89  
12.3.4.14 MAC45 – Increment MAC port 4,5 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89  
12.3.4.15 MAC67 – Increment MAC port 6,7 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89  
12.3.4.16 MAC9 – Increment MAC port 9 address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90  
12.3.4.17 CPUQINS0 - CPUQINS6 – CPU Queue Insertion Command . . . . . . . . . . . . . . . . . . . . . . 90  
12.3.4.18 CPUQINSRPT – CPU Queue Insertion Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91  
12.3.4.19 CPUGRNHDL0 - CPUGRNHDL1 – CPU Allocated Granule Pointer . . . . . . . . . . . . . . . . . 91  
12.3.4.20 CPURLSINFO0 - CPURLSINFO4 – Receive Queue Status . . . . . . . . . . . . . . . . . . . . . . . 91  
12.3.4.21 CPUGRNCTR – CPU Granule Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92  
12.3.5 (Group 4 Address) Search Engine Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92  
12.3.5.1 AGETIME_LOW – MAC address aging time Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92  
12.3.5.2 AGETIME_HIGH –MAC address aging time High . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92  
12.3.5.3 SE_OPMODE – Search Engine Operation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92  
12.3.6 (Group 5 Address) Buffer Control/QOS Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93  
9
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
12.3.6.1 QOSC – QOS Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93  
12.3.6.2 PCC – Packet Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94  
12.3.6.3 MCC – Multicast Congestion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94  
12.3.6.4 MCCTH – Multicast Threshold Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94  
12.3.6.5 RDRC0 – WRED Rate Control 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94  
12.3.6.6 RDRC1 – WRED Rate Control 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95  
12.3.6.7 RDRC2 – WRED Rate Control 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95  
12.3.6.8 SFCB – Share FCB Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95  
12.3.6.9 C1RS – Class 1 Reserve Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95  
12.3.6.10 C2RS – Class 2 Reserve Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95  
12.3.6.11 C3RS – Class 3 Reserve Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96  
12.3.6.12 AVPML – VLAN Tag Priority Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96  
12.3.6.13 AVPMM – VLAN Priority Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96  
12.3.6.14 AVPMH – VLAN Priority Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97  
12.3.6.15 AVDM – VLAN Discard Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97  
12.3.6.16 TOSPML – TOS Priority Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97  
12.3.6.17 TOSPMM – TOS Priority Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98  
12.3.6.18 TOSPMH – TOS Priority Map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98  
12.3.6.19 TOSDML – TOS Discard Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98  
12.3.6.20 USER_PROTOCOL_n – User Define Protocol 0~7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99  
12.3.6.21 USER_PROTOCOL_FORCE_DISCARD – User Define Protocol 0~7 Force Discard. . . . 99  
User Defined Logical Ports and Well Known Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99  
12.3.6.22 WELL_KNOWN_PORT[1:0]_PRIORITY- Well Known Logic Port 1 and 0 Priority . . . . . 100  
12.3.6.23 WELL_KNOWN_PORT[3:2]_PRIORITY- Well Known Logic Port 3 and 2 Priority . . . . . 100  
12.3.6.24 WELL_KNOWN_PORT[5:4]_PRIORITY- Well Known Logic Port 5 and 4 Priority . . . . . 100  
12.3.6.25 WELL_KNOWN_PORT[7:6]_PRIORITY- Well Known Logic Port 7 and 6 Priority . . . . . 101  
12.3.6.26 WELL_KNOWN_PORT_ENABLE – Well Known Logic Port 0 to 7 Enables . . . . . . . . . . 101  
12.3.6.27 WELL_KNOWN_PORT_FORCE_DISCARD – Well Known Logic Port 0~7 Force Discard. .  
101  
12.3.6.28 USER_PORT[7:0]_[LOW/HIGH] – User Define Logical Port 0~7 . . . . . . . . . . . . . . . . . . 102  
12.3.6.29 USER_PORT_[1:0]_PRIORITY - User Define Logic Port 1 and 0 Priority. . . . . . . . . . . . 102  
12.3.6.30 USER_PORT_[3:2]_PRIORITY - User Define Logic Port 3 and 2 Priority. . . . . . . . . . . . 102  
12.3.6.31 USER_PORT_[5:4]_PRIORITY - User Define Logic Port 5 and 4 Priority. . . . . . . . . . . . 103  
12.3.6.32 USER_PORT_[7:6]_PRIORITY - User Define Logic Port 7 and 6 Priority. . . . . . . . . . . . 103  
12.3.6.33 USER_PORT_ENABLE[7:0] – User Define Logic Port 0 to 7 Enables . . . . . . . . . . . . . . 103  
12.3.6.34 USER_PORT_FORCE_DISCARD[7:0] – User Define Logic Port 0~7 Force Discard . . . 103  
12.3.6.35 RLOWL – User Define Range Low Bit 7:0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104  
12.3.6.36 RLOWH – User Define Range Low Bit 15:8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104  
12.3.6.37 RHIGHL – User Define Range High Bit 7:0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104  
12.3.6.38 RHIGHH – User Define Range High Bit 15:8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104  
12.3.6.39 RPRIORITY – User Define Range Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105  
12.3.7 (Group 6 Address) MISC Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105  
12.3.7.1 MII_OP0 – MII Register Option 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105  
12.3.7.2 MII_OP1 – MII Register Option 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106  
12.3.7.3 FEN – Feature Enable Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106  
12.3.7.4 MIIC0 – MII Command Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107  
12.3.7.5 MIIC1 – MII Command Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107  
12.3.7.6 MIIC2 – MII Command Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107  
12.3.7.7 MIIC3 – MII Command Register 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108  
12.3.7.8 MIID0 – MII Data Register 0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108  
12.3.7.9 MIID1 – MII Data Register 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108  
12.3.7.10 USD – One Micro Second Divider . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108  
10  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
12.3.7.11 DEVICE - Device Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109  
12.3.7.12 CHECKSUM - EEPROM Checksum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109  
12.3.7.13 LHBTimer – Link Heart Beat Timeout Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109  
12.3.7.14 LHBReg0, LHBReg1 - Link Heart Beat OpCode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109  
12.3.7.15 fMACCReg0, fMACCReg1 - MAC Control Frame OpCode . . . . . . . . . . . . . . . . . . . . . . . 110  
12.3.7.16 FCB Base Address Register 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110  
12.3.7.17 FCB Base Address Register 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110  
12.3.7.18 FCB Base Address Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110  
12.3.8 (Group 7 Address) Port Mirroring Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110  
12.3.8.1 MIRROR CONTROL – Port Mirror Control Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110  
12.3.8.2 MIRROR_DEST_MAC[5:0] – Mirror Destination MAC Address 0~5 . . . . . . . . . . . . . . . . . 111  
12.3.8.3 MIRROR_SRC _MAC[5:0] – Mirror Source MAC Address 0~5 . . . . . . . . . . . . . . . . . . . . . 111  
12.3.8.4 RMII_MIRROR0 – RMII Mirror 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111  
12.3.8.5 RMII_MIRROR1 – RMII Mirror 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111  
12.3.9 (Group 8 Address) Per Port QOS Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112  
12.3.9.1 FCRn – Port 0~9 Flooding Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112  
12.3.9.2 BMRCn - Port 0~9 Broadcast/Multicast Rate Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112  
12.3.9.3 PR100_n – Port 0~7 Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112  
12.3.9.4 PR100_CPU – Port CPU Reservation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112  
12.3.9.5 PRM – Port MMAC Reservation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
12.3.9.6 PTH100_n – Port 0~7 Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
12.3.9.7 PTH100_CPU – Port CPU Threshold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
12.3.9.8 PTHG – Port MMAC Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
12.3.9.9 QOSC00, QOSC01 - Classes Byte Limit port 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
12.3.9.10 QOSC02, QOSC15 - Classes Byte Limit port 1-7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
12.3.9.11 QOSC16 - QOSC21 - Classes Byte Limit CPU port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114  
12.3.9.12 QOSC22 - QOSC27 - Classes Byte Limit MMAC port . . . . . . . . . . . . . . . . . . . . . . . . . . . 114  
12.3.9.13 QOSC28 - QOSC31 - Classes WFQ Credit For MMAC. . . . . . . . . . . . . . . . . . . . . . . . . . 114  
12.3.9.14 QOSC36 - QOSC39 - Shaper Control Port MMAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115  
12.3.10 (Group E Address) System Diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115  
12.3.10.1 DTSRL – Test Output Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115  
12.3.10.2 DTSRM – Test Output Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115  
12.3.10.3 TESTOUT0, TESTOUT1 – Testmux Output [7:0], [15:8] . . . . . . . . . . . . . . . . . . . . . . . . . 115  
12.3.10.4 MASK0-MASK4 – Timeout Reset Mask. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115  
12.3.10.5 BOOTSTRAP0 – BOOTSTRAP3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116  
12.3.10.6 PRTFSMST0~9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116  
12.3.10.7 PRTQOSST0-PRTQOSST7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117  
12.3.10.8 PRTQOSST8A, PRTQOSST8B (CPU port). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117  
12.3.10.9 PRTQOSST9A, PRTQOSST9B (MMAC port) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118  
12.3.10.10 CLASSQOSST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118  
12.3.10.11 PRTINTCTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119  
12.3.10.12 QMCTRL0~9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119  
12.3.10.13 QCTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119  
12.3.10.14 BMBISTR0, BMBISTR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120  
12.3.10.15 BMControl. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120  
12.3.10.16 BUFF_RST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120  
12.3.10.17 FCB_HEAD_PTR0, FCB_HEAD_PTR1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121  
12.3.10.18 FCB_TAIL_PTR0, FCB_TAIL_PTR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121  
12.3.10.19 FCB_NUM0, FCB_NUM1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121  
12.3.10.20 BM_RLSFF_CTRL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122  
12.3.10.21 BM_RSLFF_INFO[5:0] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122  
12.3.11 (Group F Address) CPU Access Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123  
11  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Table of Contents  
12.3.11.1 GCR - Global Control Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123  
12.3.11.2 DCR - Device Status and Signature Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124  
12.3.11.3 DCR1 - Device Status Register 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124  
12.3.11.4 DPST – Device Port Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124  
12.3.11.5 DTST – Data read back register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125  
12.3.11.6 DA – Dead or Alive Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125  
13.0 Characteristics and Timing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126  
13.1 Absolute Maximum Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126  
13.2 DC Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126  
13.3 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127  
13.4 AC Characteristics and Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128  
13.4.1 Typical Reset & Bootstrap Timing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128  
13.4.2 Typical CPU Timing Diagram for a CPU Write Cycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129  
13.4.3 Typical CPU Timing Diagram for a CPU Read Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130  
13.4.4 Synchronous Serial Interface (SSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131  
13.4.5 EEPROM Inter-Integrated Circuit (I²C). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132  
13.4.6 Reduced Media Independent Interface (RMII). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133  
13.4.7 Media Independent Interface (MII). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134  
13.4.8 Reverse Media Independent Interface (RvMII) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135  
13.4.9 General Purpose Serial Interface (GPSI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136  
13.4.10 Reverse General Purpose Serial Interface (RvGPSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137  
13.4.11 MII Management Data Interface (MDIO/MDC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138  
13.4.12 JTAG (IEEE 1149.1-2001) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139  
12  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
1.0 BGA and Ball Signal Descriptions  
1.1 BGA Views (Top-View)  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
A
B
C
D
E
SCLK  
P_INT  
P_CS#  
P_A0  
P_RD#  
P_A1  
P_WE  
#
P_DAT  
A1  
P_DAT  
A3  
P_DAT  
A5  
P_DAT  
A7  
P_DAT  
A9  
P_DAT  
A11  
P_DAT  
A13  
P_DAT  
A15  
REF_C  
LK  
RSVD  
TMS  
M9_M  
M9_TX  
EN  
A
B
C
D
E
TXCLK  
P_A2  
P_DAT  
A0  
P_DAT  
A2  
P_DAT  
A4  
P_DAT  
A6  
P_DAT  
A8  
P_DAT  
A10  
P_DAT  
A12  
P_DAT  
A14  
TCK  
TDI  
RSVD  
M9_RX  
CK  
RESET  
OUT#  
TSTO  
UT1  
TSTO  
UT3  
TSTO  
UT5  
TSTO  
UT6  
TSTO  
UT7  
TSTO  
UT9  
TSTO  
UT11  
TSTO  
UT12  
TSTO  
UT14  
TSTO  
UT15  
TRST#  
3.3V  
RSVD  
RSVD  
RSVD  
M9_C  
RS  
M9_C  
OL  
RESIN  
#
TSTO  
UT0  
TSTO  
UT2  
TSTO  
UT4  
3.3V  
IC_GN  
D
TSTO  
UT8  
TSTO  
UT10  
1.8V  
TSTO  
UT13  
TDO  
RSVD  
3.3V  
M9_RX  
DV  
RSVD  
RSVD  
M2_C  
OL  
M0_C  
OL  
M1_C  
OL  
3.3V  
RSVD  
RSVD  
F
G
H
J
M_MD  
C
M_MDI  
O
M0_RX  
D2  
M0_RX  
D3  
M9_RX  
D2  
M9_RX  
D3  
RSVD  
F
G
H
J
M0_RX  
D0  
M0_RX  
D1  
M0_RX  
CK  
M0_TX  
D3  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
M9_RX  
D0  
M9_RX  
D1  
M9_TX  
D2  
M9_TX  
D3  
M0_C  
RS  
M0_TX  
EN  
M0_TX  
D2  
1.8V  
1.8V  
M7_C  
OL  
M9_TX  
D0  
M9_TX  
D1  
M0_TX  
D0  
M0_TX  
D1  
M0_TX  
CK  
M1_RX  
D3  
M7_TX  
D3  
M7_TX  
CK  
M7_TX  
D1  
M7_TX  
D0  
K
L
M1_RX  
D0  
M1_RX  
D1  
M1_RX  
D2  
M1_RX  
CK  
M7_TX  
D2  
M7_RX  
D2  
M7_TX  
EN  
M7_C  
RS  
K
L
M1_C  
RS  
M1_TX  
EN  
M1_TX  
D2  
M1_TX  
D3  
M7_RX  
D3  
M7_RX  
CK  
M7_RX  
D1  
M7_RX  
D0  
M
M1_TX  
D0  
M1_TX  
D1  
M1_TX  
CK  
3.3V  
3.3V  
M6_C  
OL  
M5_C  
OL  
M4_C  
OL  
M
N
P
R
T
M2_RX  
D3  
M2_TX  
CK  
M2_TX  
D3  
M3_RX  
D3  
3.3V  
M3_TX  
D3  
1.8V  
M4_RX  
D3  
M4_TX  
CK  
M4_TX  
D3  
M5_RX  
D3  
M5_TX  
CK  
M5_TX  
D3  
M6_RX  
D3  
M6_TX  
CK  
M6_TX  
D3  
N
P
R
T
M2_RX  
D2  
M2_RX  
CK  
M2_TX  
D2  
M3_RX  
D2  
M3_RX  
CK  
M3_TX  
D2  
M3_C  
OL  
M4_RX  
D2  
M4_RX  
CK  
M4_TX  
D2  
M5_RX  
D2  
M5_RX  
CK  
M5_TX  
D2  
M6_RX  
D2  
M6_RX  
CK  
M6_TX  
D2  
M2_RX  
D1  
M2_TX  
EN  
M2_TX  
D1  
M3_RX  
D1  
M3_TX  
EN  
M3_TX  
D1  
M_CLK  
M4_RX  
D1  
M4_TX  
EN  
M4_TX  
D1  
M5_RX  
D1  
M5_TX  
EN  
M5_TX  
D1  
M6_RX  
D1  
M6_TX  
EN  
M6_TX  
D1  
M2_RX  
D0  
M2_C  
RS  
M2_TX  
D0  
M3_RX  
D0  
M3_C  
RS  
M3_TX  
D0  
M3_TX  
CK  
M4_RX  
D0  
M4_C  
RS  
M4_TX  
D0  
M5_RX  
D0  
M5_C  
RS  
M5_TX  
D0  
M6_RX  
D0  
M6_C  
RS  
M6_TX  
D0  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
1.2 Power and Ground Distribution  
G7-10, H7-10, J7-10, K7-10  
GND  
3.3V  
V
V
Ground  
SS  
CC  
D5, D12, E4, E13, M4, M13,  
N5  
I/O Power  
D9, H4, H13, N7  
1.8V  
V
Core Power  
DD  
13  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
1.3 Ball Signal Descriptions  
All pins are CMOS type; all Input Pins are 5 Volt tolerance; and all Output Pins are 3.3 CMOS drive.  
Notes  
# =  
Active low signal  
Input =  
Input signal  
Input-ST =  
Output =  
I/O-TS =  
pull-up =  
Input signal with Schmitt-Trigger  
Output signal (Tri-State driver)  
Input & Output signal with Tri-State driver  
Weak internal pull-up (nominal 100K)  
(refer to Section 1.4 on page 19 as some internal  
pull-ups are not enabled in certain configurations)  
pull-down =  
Weak internal pull-down (nominal 100K)  
(refer to Section 1.4 on page 19 as some internal  
pull-downs are not enabled in certain configurations)  
Ball Signal Description Table  
Ball No(s)  
Symbol  
I/O  
Description  
16-Bit CPU Bus Interface  
A12, B12, A11, B11,  
A10, B10, A9, B9, A8,  
B8, A7, B7, A6, B6,  
A5, B5  
P_DATA[15:0]  
I/O-TS  
Processor Bus Data Bit [15:0]. P_DATA[7:0] is  
used in 8-bit mode.  
with pull-up  
B4, B3, B2  
P_A[2:0]  
P_WE#  
Input  
Processor Bus Address Bit [2:0]  
CPU Bus-Write Enable  
with pull-up  
A4  
Input  
with pull-up  
A3  
A2  
P_RD#  
P_CS#  
Input  
CPU Bus-Read Enable  
Chip Select  
Input  
with pull-up  
B1  
P_INT  
Output  
CPU Interrupt  
Active high, but can be changed via register  
DEVICE, bit [1].  
Fast Ethernet Access Ports [7:0] MII  
14  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Ball Signal Description Table (continued)  
Ball No(s)  
Symbol  
I/O  
Description  
L13, K14, L15, L16,  
N14, P14, R14, T14,  
N11, P11, R11, T11,  
N8, P8, R8, T8, N4,  
P4, R4, T4, N1, P1,  
R1, T1, J4, K3, K2,  
K1, F4, F3, G2, G1  
M[7:0]_RXD[3:0] Input  
Ports [7:0] – Receive Data Bit [3:0]  
with pull-up  
K16, T15, T12, T9, T5, M[7:0]_CRS_DV Input  
Ports [7:0] – Carrier Sense and Receive Data  
Valid  
T2, L1, H1  
with pull-up  
K15, R15, R12, R9,  
R5, R2, L2, H2  
M[7:0]_TXEN  
Output, slew  
Ports [7:0] – Transmit Enable  
This pin also serves as a bootstrap pin.  
Ports [7:0] – Transmit Data Bit [3:0]  
J13, K13, J15, J16,  
N16, P16, R16, T16,  
N13, P13, R13, T13,  
N10, P10, R10, T10,  
N6, P6, R6, T6, N3,  
P3, R3, T3, L4, L3,  
M2, M1, G4, H3, J2,  
J1  
M[7:0]_TXD[3:0] Output, slew  
H14, M14, M15, M16, M[7:0]_COL  
P7, E1, E3, E2  
Input  
Ports[7:0] – Collision  
with pull-down  
J14, N15, N12, N9,  
T7, N2, M3, J3  
M[7:0]_TXCLK  
Input or Output  
with pull-up  
Ports[7:0] – Transmit Clock  
This pin in an output if ECR4Pn[1:0]='11'  
Ports[7:0] – Receive Clock  
L14, P15, P12, P9,  
P5, P2, K4, G3  
M[7:0]_RXCLK  
Input or Output  
with pull-up  
This pin in an output if ECR4Pn[1:0]='11'  
Fast Ethernet Uplink Port MII  
G16, G15, H16, H15  
D15  
M9_TXD[3:0]  
Output  
Transmit Data Bit [3:0]  
Receive Data Valid  
M9_RXDV  
Input  
with pull-up  
C15  
C16  
B16  
M9_CRS  
Input  
Carrier Sense  
with pull-down  
M9_COL  
Input  
Collision Detected  
with pull-down  
M9_RXCLK  
Input or Output  
with pull-up  
Receive Clock  
This pin in an output if ECR4P9[1:0]='11'  
Receive Data Bit [3:0]  
F14, F13, G14, G13  
M9_RXD[3:0]  
Input  
with pull-up  
15  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Ball Signal Description Table (continued)  
Ball No(s) Symbol  
M9_TXEN  
I/O  
Description  
Transmit Data Enable  
A16  
A15  
Output  
with pull-up  
M9_MTXCLK  
Input  
Transmit Clock  
with pull-up  
Test Interface  
C11, C10, D10, C9,  
C8, D8, C7, D7, C6,  
C5, C4, D4, C3, D3,  
C2, D2  
TSTOUT[15:0]  
Output  
[15:4] Reserved  
[3] EEPROM checksum is good  
[2] Initialization Completed  
[1] Memory Self Test in progress  
[0] Initialization started  
These pins also serve as bootstrap pins.  
Test Facility  
C13  
TDI  
Input  
JTAG - Test Data In  
JTAG - Test Reset  
with pull-up  
C12  
TRST#  
Input  
with pull-up  
In normal operation, this pin should be pulled  
low. Recommend weak external pull-down  
resistor (470 to 1 k).  
B13  
B14  
D11  
TCK  
TMS  
TDO  
Input  
JTAG - Test Clock  
with pull-up  
Input  
JTAG - Test Mode State  
JTAG - Test Data Out  
with pull-up  
Output  
System Clock, Power, and Ground Pins  
A1  
SCLK  
Input  
System Clock. Based on system requirement,  
SCLK needs to operate at difference  
frequency.  
SCLK requires 40/60% duty cycle clock.  
D9, H4, H13, N7,  
V
V
Power  
Power  
+1.8 Volt DC Supply  
+3.3 Volt DC Supply  
DD  
CC  
D5, D12, E4, E13, M4,  
M13, N5,  
G7-10, H7-10, J7-10,  
K7-10  
V
Power Ground  
Ground  
SS  
Misc.  
D1  
RESIN#  
Input  
Reset Input  
Reset PHY  
C1  
RESETOUT#  
Output  
16  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Ball Signal Description Table (continued)  
Ball No(s) Symbol  
M_MDC  
I/O  
Description  
F1  
F2  
Output  
I/O-TS  
MII Management Data Clock  
MII Management Data I/O  
M_MDIO  
with pull-up  
R7  
M_CLK  
Input  
RMAC Reference Clock  
MMAC Reference Clock  
A13  
REF_CLK  
Input  
with pull-up  
, C14, D14, D13, E14, RSVD  
E16, E15, F16, F15,  
D16, B15, A14  
N/A  
Reserved. Leave unconnected.  
D6  
IC_GND  
IC_GND  
Internal Connect. Tie to ground (V ) via 1 K  
SS  
resistor.  
1
Bootstrap Pins  
External pull-up/down resistors are required on all bootstrap pins for proper operation. See “Bootstrap Options” on  
page 22 for more information.  
D2  
TSTOUT[0]  
Input (Reset Only)  
Enable Debounce on SSI interface  
Pullup – Enabled  
Pulldown - Disabled  
When enabled, DATAOUT is an open-drain  
output; when disabled, DATAOUT is a  
totem-pole output.  
See “Synchronous Serial Interface (SSI)” on  
page 131 for more details on debounce  
timing.  
C3, D3, C2  
TSTOUT[3:1]  
Input (Reset Only)  
Management interface operation mode:  
000 – 16-bit parallel interface  
001 – 8-bit parallel interface  
010 – Serial with MII as Ethernet frame  
transfer interface.  
011 – Serial only. CPU can transmit/receive  
frames with the serial interface.  
111 – Unmanaged Serial. No CPU packet can  
be transmit or received with the serial  
interface. EEPROM can be used to configure  
the device at bootup.  
A one (1) indicates pullup. A zero (0)  
indicates pulldown. TSTOUT[1] is the Least  
Significant Bit (LSB).  
17  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Ball Signal Description Table (continued)  
Ball No(s)  
C5, C4, D4  
Symbol  
I/O  
Description  
TSTOUT[6:4]  
Input (Reset Only)  
Device ID. Default address of the device for  
serial interface. Up to 8 device can be sharing  
the serial management bus with different  
device ID.  
A one (1) indicates pullup. A zero (0)  
indicates pulldown. TSTOUT[4] is the Least  
Significant Bit (LSB).  
C6  
D7  
TSTOUT[7]  
TSTOUT[8]  
Input (Reset Only)  
Input (Reset Only)  
EEPROM not installed.  
Pullup: Not installed  
Pulldown: Installed  
Manufacturing Option. Must be pulled up.  
Must be externally  
pulled-up  
C7  
D8  
TSTOUT[9]  
Input (Reset Only)  
Module Detect  
Pullup: Enable. In this mode, the device will  
detect the existence of a PHY (for hot swap  
purpose).  
Pulldown: Disable  
TSTOUT[10]  
Input (Reset Only)  
Manufacturing Option. Must be pulled down.  
Must be externally  
pulled-down  
C8  
TSTOUT[11]  
TSTOUT[12]  
Input (Reset Only)  
Power Saving  
Pullup: Enable MAC power saving mode  
Pulldown: Disable MAC power saving mode  
C9  
Input (Reset Only)  
Timeout Reset Enable  
Pullup: Enable  
Pulldown: Disable  
C11, C10, D10  
TSTOUT[15:13] Input (Reset Only)  
Manufacturing Options. Must be pulled-up.  
Must be externally  
pulled-up  
K15, R15, R12, R9,  
R5, R2, L2, H2  
M[7:0]_TXEN  
Input (Reset Only)  
User Defined Bootstrap:  
Usually used in conjuction with Module Detect  
to determine what interface to use for the  
inserted module. Can be read from  
BOOTSTRAP2 register  
1. Note: 1=pull-up; 0=pull-down  
18  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
1.4 Signal Mapping and Internal pull-up/Down Configuration  
The ZL50409 Fast Ethernet access ports (0-7) support 3 interface options: RMII, MII & GPSI. The table below  
summarizes the interface signals required for each interface and how they relate back to the Pin Symbol name  
shown in the “Ball Signal Description Table” on page 14. It also specifies whether the internal pull-up/down resistor  
is present for each pin in the specific operating mode.  
Notes:  
I – Input  
O – Output  
U – Pullup  
D - Pulldown  
No  
Fast Ethernet  
Access Ports  
Pin Symbol  
RMII Mode  
MII Mode  
GPSI Mode  
Module  
(ECR4Pn[4:3]='11')  
(ECR4Pn[4:3]='01')  
(ECR4Pn[4:3]='00')  
(Bootstrap  
TSTOUT9=’1’)  
M[7:0]_RXD0  
(U)  
(U)  
(U)  
(U)  
(O)  
(U)  
(O)  
(O)  
(O)  
(O)  
(D)  
(U)  
(U)  
M[7:0]_RXD0 (I)  
M[7:0]_RXD1 (I)  
NC (U)  
M[7:0]_RXD0 (I)  
M[7:0]_RXD1 (I)  
M[7:0]_RXD2 (I)  
M[7:0]_RXD3 (I)  
M[7:0]_TXEN (O)  
M[7:0]_DV (I)  
M[7:0]_TXD0 (O)  
M[7:0]_TXD1 (O)  
M[7:0]_TXD2 (O)  
M[7:0]_TXD3 (O)  
M[7:0]_COL (I)  
M[7:0]_RXD (I)  
NC (U)  
NC (U)  
NC (U)  
M[7:0]_TXEN (O)  
M[7:0]_CRS (I)  
M[7:0]_TXD (O)  
NC (O)  
NC (O)  
NC (O)  
M[7:0]_RXD1  
M[7:0]_RXD2  
M[7:0]_RXD3  
M[7:0]_TXEN  
M[7:0]_CRS_DV  
M[7:0]_TXD0  
M[7:0]_TXD1  
M[7:0]_TXD2  
M[7:0]_TXD3  
M[7:0]_COL  
NC (U)  
M[7:0]_TXEN (O)  
M[7:0]_CRS_DV (I)  
M[7:0]_TXD0 (O)  
M[7:0]_TXD1 (O)  
NC (O)  
NC (O)  
NC (D)  
NC (U)  
NC (U)  
M[7:0]_COL (I)  
M[7:0]_TXCLK (IO)  
M[7:0]_RXCLK (IO)  
M[7:0]_TXCLK  
M[7:0]_RXCLK  
M[7:0]_TXCLK (IO)  
M[7:0]_RXCLK (IO)  
Table 1 - Signal Mapping In Different Operation Mode  
19  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
The ZL50409 Fast Ethernet uplink port (port 9) supports 1 interface option: MII. The table below summarizes the  
interface signals required for each interface, and how they relate back to the Pin Symbol name shown in “Ball  
Signal Description Table” on page 14.  
No  
Fast Ethernet  
Uplink Port  
Pin Symbol  
MII Mode  
Module  
(ECR4P9[4:3]='11')  
(Bootstrap  
TSTOUT9=’1’)  
M9_RXD0  
M9_RXD1  
M9_RXD2  
M9_RXD3  
M9_RXDV  
M9_CRS  
(U)  
(U)  
(U)  
(U)  
(U)  
(D)  
(D)  
(U)  
(O)  
(O)  
(O)  
(O)  
(U)  
(U)  
(U)  
M9_RXD0 (I)  
M9_RXD1 (I)  
M9_RXD2 (I)  
M9_RXD3 (I)  
M9_RXDV (I)  
M9_CRS (I)  
M9_COL  
M9_COL (I)  
M9_RXCLK  
M9_TXD0  
M9_TXD1  
M9_TXD2  
M9_TXD3  
M9_TXEN  
REF_CLK  
M9_MTXCLK  
M9_RXCLK (IO)  
M9_TXD0 (O)  
M9_TXD1 (O)  
M9_TXD2 (O)  
M9_TXD3 (O)  
M9_TXEN (O)  
REF_CLK (I)  
M9_MTXCLK (I)  
Table 2 - Signal Mapping In Different Operation Mode  
20  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
The ZL50409 CPU access support 5 interface options: 8 or 16-bit parallel, serial+MII (port 8), serial only, and  
unmanaged serial (with optional EEPROM). The table below summarizes the interface signals required for each  
interface, and how they relate back to the Pin Symbol name shown in “Ball Signal Description Table” on page 14.  
Management  
16-bit CPU  
8-bit CPU  
Serial with MII  
Serial Only  
Interface  
(TSTOUT[3:1]=’000’)  
(TSTOUT[3:1]=’001’)  
(TSTOUT[3:1]=’010’)  
(TSTOUT[3:1]=’011’ or ‘111’)  
Pin Symbol  
P_A[0]  
P_A[0] (I)  
P_A[0] (I)  
NC (U)  
SDA (IOU) (111 only)  
SCL (OU) (111 only)  
NC (U)  
P_A[1]  
P_A[1] (I)  
P_A[1] (I)  
NC (U)  
P_A[2]  
P_A[2] (I)  
P_A[2] (I)  
NC (U)  
P_WE#  
P_WE# (I)  
P_WE# (I)  
P_RD# (I)  
STROBE (IU)  
DATAOUT (O)  
DATAIN (IU)  
STROBE (IU)  
DATAOUT (O)  
DATAIN (IU)  
P_INT (O)  
P_RD#  
P_RD# (I)  
P_CS#  
P_CS# (I)  
P_CS# (I)  
P_INT  
P_INT (O)  
P_INT (O)  
P_DATA0 (IOU)  
P_DATA1 (IOU)  
P_DATA2 (IOU)  
P_DATA3 (IOU)  
P_DATA4 (IOU)  
P_DATA5 (IOU)  
P_DATA6 (IOU)  
P_DATA7 (IOU)  
NC (U)  
P_INT (O)  
P_DATA0  
P_DATA1  
P_DATA2  
P_DATA3  
P_DATA4  
P_DATA5  
P_DATA6  
P_DATA7  
P_DATA8  
P_DATA9  
P_DATA10  
P_DATA11  
P_DATA12  
P_DATA13  
P_DATA14  
P_DATA15  
P_DATA0 (IOU)  
P_DATA1 (IOU)  
P_DATA2 (IOU)  
P_DATA3 (IOU)  
P_DATA4 (IOU)  
P_DATA5 (IOU)  
P_DATA6 (IOU)  
P_DATA7 (IOU)  
P_DATA8 (IOU)  
P_DATA9 (IOU)  
P_DATA10 (IOU)  
P_DATA11 (IOU)  
P_DATA12 (IOU)  
P_DATA13 (IOU)  
P_DATA14 (IOU)  
P_DATA15 (IOU)  
CPU_MII_TXD0 (O)  
CPU_MII_TXD1 (O)  
CPU_MII_TXD2 (O)  
CPU_MII_TXD3 (O)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
CPU_MII_TXCLK (O) NC (U)  
CPU_MII_TXEN (O)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
CPU_MII_RXD0 (I)  
CPU_MII_RXD1 (I)  
CPU_MII_RXD2 (I)  
CPU_MII_RXD3 (I)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
CPU_MII_RXCLK (O) NC (U)  
NC (U)  
CPU_MII_RXDV (I)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
NC (U)  
Table 3 - Signal Mapping In Different Operation Mode  
21  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
1.5 Bootstrap Options  
TSTOUT[15:0] and M[7:0]_TXEN pins serve as bootstrap pins during device power-up or reset. Please refer to  
“Typical Reset & Bootstrap Timing Diagram” on page 128 for more information on when the bootstrap pins are  
sampled. The bootstrap pins require external pull-up/down resistors for proper operation. Recommend 10 K for  
pull-ups and 1 K for pull-downs.  
The table below summarizes the bootstrap options.  
Feature  
CPU Interface  
Description  
The ZL50409 allows the selection of 5 different management interfaces:  
2
8/16-bit parallel, serial with MII, serial only and unmanaged serial with I C  
EEPROM.  
TSTOUT[3:1] is used to select the interface options mentioned above. If the  
serial interface is selected, addition bootstrap options are required:  
TSTOUT[0] enables or disables the DEBOUNCE feature (refer to  
“Synchronous Serial Interface” on page 35)  
TSTOUT[6:4] selects the device ID  
2
Also, in unmanaged mode, an optional I C EEPROM can be used to configure  
the device at power-up or reset. TSTOUT[7] selects the EEPROM option.  
Ethernet Interface  
Misc. Features  
The ZL50409 supports module hotswap on all it's ports. This is enabled via  
TSTOUT[9]. When enabled, bootstrap pins M[7:0]_TXEN (ports 0-7) are used  
to specify the module type to support multiple ethernet interfaces during  
module hotswap.  
Another feature is the MAC power savings mode. When enabled via  
TSTOUT[11], each port's MAC will detect inactivity on the port and go into a  
power savings state. When activity is detected once again on the port, the MAC  
will come out of this state.  
One other feature selected via bootstrap is Timeout Reset Enable  
(TSTOUT[12]). This enables a monitoring block with the device which will  
detect if any hardware state machine is in a non-idle state for more than 5  
seconds.  
Refer to section 2.7 for more details on this feature.  
Table 4 - Bootstrap Features  
1.5.1 Recommended Default Bootstrap Settings  
The following are the recommended default settings for the bootstrap options:  
Unmanaged/Lightly Managed  
Reserved/Manufacturing bootstraps  
-
-
TSTOUT[15:13,8] must be pulled-up  
TSTOUT[10] must be pulled-down  
CPU Interface:  
-
Strobe debounce bootstrap, TSTOUT[0], should be normally pulled-up, unless you wish to disable the  
debounce logic  
-
CPU Interface bootstrap, TSTOUT[3:1], should be pulled-up to indicate unmanaged SSI CPU  
interface. To enable SSI-only lightly managed mode, pulled-down TSTOUT[3]. To enable SSI+MII  
lightly managed mode, pulled-down TSTOUT[3,1]  
22  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
-
-
SSI Device ID bootstrap, TSTOUT[6:4], should be pulled-down to indicate device ID 0x0 for the SSI  
interface. Can be changed to whatever device ID required if more than one device on the SSI bus.  
EEPROM bootstrap, TSTOUT[7], should be pulled-up to disable until the system is debugged. You  
can pull-down this bootstrap if using the optional EEPROM in unmanaged mode (NOTE: this bootstrap  
is not valid in any other CPU mode)  
Module Detect bootstrap, TSTOUT[9], should be pulled-down  
-
-
In lightly managed mode, you can enable the optional Module Detect feature  
If enabled, need to use Mn_TXEN to indicate module type  
Power Saving bootstrap, TSTOUT[11], should be normally pulled-up  
Timeout Reset bootstrap, TSTOUT[12], should be pull-down  
- Once system is debugged, you can enable the optional feature with pull-up (Refer to section 2.7 for more  
details on this feature)  
Managed  
Reserved/Manufacturing bootstraps  
-
-
TSTOUT[15:13,6:4,8,7,0] must be pulled-up  
TSTOUT[10] must be pulled-down  
CPU Interface  
-
-
TSTOUT[3:1], should be pulled-down to indicate 16-bit CPU mode  
For 8-bit CPU mode, pull-up TSTOUT[1]  
Module Detect bootstrap, TSTOUT[9], should be pulled-down, unless using the Module Detect feature  
-
If enabled, need to use Mn_TXEN to indicate module type  
Power Saving bootstrap, TSTOUT[11], should be normally pulled-up  
Timeout Reset bootstrap, TSTOUT[12], should be pull-down  
-
Once system is debugged, you can enable the optional feature with pull-up (Refer to section 2.7 for  
more details on this feature)  
1.6 Default Switch Configuration and Initialization Sequence  
The ZL50409 will come out of reset in a default configuration, which will allow for basic L2 switching and automatic  
MAC address learning.  
In unmanaged mode, the default configuration will take effect immediately after reset. The default settings can be  
changed using the optional EEPROM.  
System Defaults  
Port-based VLAN  
MAC address 00-00-00-00-00-00 not learned  
Drop MAC addresses 01-80-C2-00-00-01~F  
No IP multicast switching support  
Trunking and mirroring disabled  
MAC address agetime is 300 seconds  
VLAN 802.1p prioritization  
-
All priority bits mapped to priority 0 (lowest)  
96 queued unicast/multicast frames will trigger flow control  
All WRED drop percentages equal to 0%  
Unicast/multicast/broadcast flood control disabled  
No shared or per-class buffer pools  
Per-port Defaults  
Disable per-port fixed priority and drop precedence  
Disable asynchronous flow control  
Spanning Tree per-port state equal to forwarding  
Don’t filter tagged/untagged VLAN frames  
23  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Automatic learning enabled  
Per-port security disabled  
Support frame size 64 <= n <= 1522  
Pad transmit frames < 64B  
Standard preamble  
Strict Priority scheduling  
FE Ports  
-
-
-
-
RMII mode  
Auto-negotiate 10/100 M, Full Duplex, Flow Control  
Rate control disabled  
per-source port buffer pool of 96 buffers, with flow control threshold of 48 buffers  
Uplink Port  
-
-
-
MII mode  
Auto-negotiate 10/100 M, Full Duplex, Flow Control  
per-source port buffer pool of 384 buffers, with flow control threshold of 192 buffers  
In lightly managed/managed mode, the default configuration can be used as well, however, the device needs to be  
told when to start switching. This is done via the “Init Complete” bit, set in GCR[4]. The default settings can be  
overridden using the CPU interface, but should be done before setting of GCR[4]. One thing to note is after reset,  
the device will start to initialize the control tables. Therefore, a short delay (100 us~1 ms) is necessary before  
changing the register settings and/or control tables, and before setting GCR[4].  
System Defaults  
CPU MAC address is 00-00-00-00-00-00  
Forward MAC addresses 01-80-C2-00-00-00~F to CPU port  
-
Except 01-80-C2-00-00-01~F, which are dropped  
All interrupts enabled  
MAC address learn report to CPU disabled  
Statistics counters disabled  
DiffServ EF code support disabled  
No VLAN ID hashing  
Per-port Defaults  
FE Ports  
-
Link heart beat disabled  
CPU Port  
-
-
-
100 M, Full Duplex, Flow Control  
8-byte header padding  
per-source port buffer pool of 96 buffers, with flow control threshold of 48 buffers  
24  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
1.7 Power Sequencing  
The ZL50409 has two separate power supplies: V  
(1.8 V) and V  
(3.3 V). The recommended power-up  
CC  
DD  
sequence is for V to be applied first, followed by the V supply. V should lead V supply by at least 0.2 V,  
CC  
DD  
CC  
DD  
but by no more than 2 V.  
Both supplies may be powered-down simultaneously.  
I/O supply (VCC = 3.3V)  
Core supply (VDD = 1.8V)  
>0.2 VDC  
VDC  
t
t
RESIN  
> 10 µs  
SCLK  
t
10 ns  
Figure 2 - Power-up Sequence  
See “Typical Reset & Bootstrap Timing Diagram” on page 128 for more details on reset and bootstrap sampling.  
2.0 Block Functionality  
Uplink MAC  
Interface  
Fast  
Ethernet  
Port  
Fast Ethernet  
MAC  
Frame Engine  
& Queuing  
8 Fast  
Ethernet  
Ports  
Interface  
Per -Class Traffic Shaping,  
SP/WFQ Scheduling,  
CPU MAC  
Fast  
Ethernet  
Port  
(RMII/MII/GPSI)  
Interface  
(RvMII)  
Congestion WRED  
Network Management  
Database & RMON Counters  
192 KB  
Frame  
64 KB  
Switch  
Buffer  
L2 Search Engine  
Single -Field Classifier,  
4K MAC, 4K VLAN  
Control  
Memory  
Databases  
Management Module  
I2C & Serial  
MDIO  
*CPU 8/16 Bit  
Parallel Interface  
JTAG  
Interface  
Interface  
Figure 3 - Functional Block Diagram  
25  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
2.1 Internal Memory  
Two Megabit of internal memory is provided for ethernet Frame Data Buffering (FDB), storing of MAC Control Table  
database (MCT), and the Network Management (NM) Database statistics counters and MIB.  
The MCT is used for storing MAC addresses and their physical port number. The FDB is used for storing the  
received frame data contents. The contents are stored in this memory until it is ready to be transmitted to the  
egress port.  
A memory arbiter is used to arbitrary the memory access requests from various sources. A Built In Self Test (BIST)  
is used to detect any error in the memory array when the device is powered up. The BIST can also be requested by  
the writing to the GCR register.  
2.2 MAC Modules  
2.2.1 RMII MAC Module (RMAC)  
The RMII Media Access Control (RMAC) module provides the necessary buffers and control interface between the  
Frame Engine (FE) and the external physical device (PHY). It has five interfaces: MII, RMII, GPSI (only for 10M),  
Reverse MII, or Reverse GPSI (only for 10M).  
The RMAC of the ZL50409 device meets the IEEE 802.3 specification. It is able to operate in either Half or Full  
Duplex mode with a back pressure/flow control mechanism. In addition, it will automatically retransmit upon  
collision for up to 16 total transmissions.  
These eight ports are denoted as ports 0 to 7. The PHY addresses for the PHY devices connected to the 8 RMAC  
ports has to be from 08h (port 0) to 0Fh (port 7).  
2.2.1.1 GPSI (7WS) Interface  
The RMAC ethernet port can function in GPSI (7WS) mode. In this mode, the TXD[0], RXD[0] serve as TX data, RX  
data and respectively. The link and duplex of the port can be controlled by programming the ECR1Pn register. Only  
port-based VLAN is supported with GPSI interface.  
2.2.2 CPU MAC Module (CMAC)  
The CPU Media Access Control (CMAC) module provides the necessary buffers and control interface between the  
Frame Engine (FE) and the external CPU device. It support either a Reverse MII interface, providing the necessary  
interface TX and RX clocks to the CPU, or a register access mechanism via the 8/16-bit or serial interface.  
Using the MII interface, the CMAC of the ZL50409 device meets the IEEE 802.3 specification. It is able to operate  
in either Half or Full Duplex mode with a back pressure/flow control mechanism. In addition, it will automatically  
retransmit upon collision for up to 16 total transmissions.  
This port is denoted as port 8.  
2.2.3 MII MAC Module (MMAC)  
The MII Media Access Control (MMAC) module provides the necessary buffers and control interface between the  
Frame Engine (FE) and the external physical device (PHY). The MMAC implements an MII interface.  
The MMAC of the ZL50409 device meets the IEEE 802.3 specification. It is able to operate in 10 M/100 M either  
Half or Full Duplex mode with a back pressure/flow control mechanism. Furthermore, it will automatically retransmit  
upon collision for up to 16 total transmissions.  
This port is denoted as port 9. The PHY address for the PHY device connected to the MMAC port has to be 10h.  
26  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
2.2.4 PHY Addresses  
The table below provides an overview of the PHY addresses required for each port in order for the MDIO  
auto-negotiation to work between the ZL50409 MAC and the PHY device. If a different PHY address is used, then  
the port must be manually brought up and the PHY will need to be polled for link status via the MIIC/D registers.  
MAC Port  
PHY Address  
RMAC Port 0  
RMAC Port 1  
...  
0x08  
0x09  
...  
RMAC Port 7  
CMAC Port 8  
MMAC Port 9  
0x0F  
NA  
0x10  
Table 5 - PHY Addresses  
2.3 Management Module  
The CPU can send a control frame to access or configure the internal network management database. The  
Management Module decodes the control frame and executes the functions requested by the CPU.  
This module is only active in managed mode. In unmanaged mode, no control frame is accepted by the device.  
2.4 Frame Engine  
The main function of the frame engine is to forward a frame to its proper destination port or ports. When a frame  
arrives, the frame engine parses the frame header (64 bytes) and formulates a switching request, sent to the  
search engine, to resolve the destination port. The arriving frame is moved to the internal memory. After receiving a  
switch response from the search engine, the frame engine performs transmission scheduling based on the frame’s  
priority. The frame engine forwards the frame to the MAC module when the frame is ready to be sent.  
2.5 Search Engine  
The Search Engine resolves the frame’s destination port or ports according to the destination MAC address (L2), or  
IP multicast address (L3) by searching the database. It also performs unicast MAC learning, trunking functions, and  
priority assignment.  
2.6 Heartbeat Packet Generation and Response  
The ZL50409 provides the ability to monitor a link and detect a simple link failure. The Link Heart Beat (LHB) packet  
generation module allows simultaneous tracking of all the RMAC ports.  
Periodically, a LHB message will be sent for each link when inactivity is detected with in a programmable time  
period, If a reply is not received in a specified amount of time, the failover detection module will identify a  
point-to-point failure for that link. The failover detection module will then interrupt the CPU.  
The LHB packet response module can also reply to LHB messages initiated by other ZL50409 devices in the  
system, or by non-ZL50409 devices which use a conventional and recognizable LHB message format.  
2.7 Timeout Reset Monitor  
The ZL50409 supports a state machine monitoring block which can trigger a reset or interrupt if any state machine  
is determined to be stuck in a non-idle state for more than 5 seconds. This feature is enabled via a bootstrap pin  
(TSTOUT12). It also requires some register configuration via the CPU interface.  
See Programming Timeout Reset application note, ZLAN-41, for more information.  
27  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
2.8 JTAG  
An IEEE1149.1 compliant test interface is provided for boundary scan. The JTAG interface, collectively known as a  
Test Access Port, or TAP, uses the following signals to support the operation of boundary scan:  
TCK – the TCK or ‘test clock’ synchronizes the internal state machine operations  
TMS – the TMS or ‘test mode state’ is sampled at the rising edge of TCK to determine the next state  
TDI – the TDI or ‘test data in’ represents the data shifted into the device’s test or programming logic. It is  
sampled at the rising edge of TCK when the internal state machine is in the correct state  
TDO – the TDO or ‘test data out’ represents the data shifted out of the device’s test or programming logic  
and is valid on the falling edge of TCK when the internal state machine is in the correct state  
TRST – the TRST or ‘test reset’ is an optional pin which, when available, can reset the TAP controller’s state  
machine  
2.8.1 Registers  
There are two types of registers associated with boundary scan. Each compliant device has one instruction register  
and two or more data registers.  
Instruction Register – the instruction register holds the current instruction. Its content is used by the TAP  
controller to decide what to do with signals that are received. Most commonly, the content of the instruction  
register will define to which of the data registers signals should be passed.  
Data Registers – there are three primary data registers, the Boundary Scan Register (BSR), the BYPASS  
register and the IDCODES register. Other data registers may be present, but they are not required as part of  
the JTAG standard.  
BSR – this is the main testing data register. It is used to move data to and from the ‘pins’ on a device.  
BYPASS – this is a single-bit register that passes information from TDI to TDO. It allows other devices in  
a circuit to be tested with minimal overhead.  
IDCODES – this register contains the ID code and revision number for the device. This information allows  
the device to be linked to its Boundary Scan Description Language (BSDL) file. The file contains details of  
the Boundary Scan configuration for the device.  
2.8.2 Test Access Port (TAP) Controller  
The TAP controller, a state machine whose transitions are controlled by the TMS signal, controls the behaviour of  
the JTAG system. For more detail on each state, refer to the IEEE 1149.1 Standard JTAG document.  
2.8.3 Boundary Scan Instructions  
The IEEE 1149.1 standard defines a set of instructions that must be available for a device to be considered  
compliant. These instructions are:  
BYPASS – the BYPASS instruction causes the TDI and TDO lines to be connected via a single-bit  
pass-through register (the BYPASS register). This instruction allows the testing of other devices in the JTAG  
chain without any unnecessary overhead.  
EXTEST – the EXTEST instruction causes the TDI and TDO to be connected to the Boundary Scan Register  
(BSR). The device’s pin states are sampled with the ‘capture dr’ JTAG state and new values are shifted into  
the BSR with the ‘shift dr’ state; these values are then applied to the pins of the device using the ‘update dr’  
state.  
SAMPLE/PRELOAD – the SAMPLE/PRELOAD instruction causes the TDI and TDO to be connected to the  
BSR. However, the device is left in its normal functional mode. During this instruction, the BSR can be  
accessed by a data scan operation to take a sample of the functional data entering and leaving the device.  
The instruction is also used to preload test data into the BSR prior to loading an EXTEST instruction.  
28  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Other available instructions for the ZL50409 include:  
IDCODE – the IDCODE instruction causes the TDI and TDO to be connected to the IDCODE register.  
HIGHZ – the HIGHZ instruction causes all of the logic outputs to be placed in an inactive drive state (e.g.,  
high impedance).  
3.0 Management and Configuration  
One extra port is dedicated to the CPU via the CPU interface module. Three modes this port can operate:  
managed, lightly managed or unmanaged mode. The different between these modes is tx/rx Ethernet frame, tx/rx  
control frame and receiving interrupt due to the lack of constant attention or processing power from the CPU.  
2
The CPU interface utilizes a 8/16-bit bus in managed mode. It also supports a serial+MII, serial only, and an I C  
interface, which provides an easy and lower cost way to configure the system for reduced management.  
Supported CPU interface modes are  
Operation Mode  
16-bit CPU  
ISA Interface  
Serial  
MII  
I²C  
16-bit  
8-bit  
NA  
NA  
NA  
NA  
Yes  
No  
No  
NA  
NA  
No  
No  
Yes  
8-bit CPU  
NA  
Serial with MII interface  
Lightly Managed Serial  
Unmanaged Serial  
Yes  
Yes  
Yes  
NA  
NA  
Table 6 - Supported CPU interface modes  
1. 16-bit CPU interface similar to the Industry Standard Architecture (ISA) specification.  
2. 8-bit CPU interface similar to ISA.  
3. Serial with MII. A synchronous serial interface (SSI) bus is used for accessing the configuration register and  
control frame. MII is used for sending and receiving CPU packets.  
4. Lightly Managed Serial. Configuration registers access, Control frame and CPU transmit/receive packets are  
sent through a synchronous serial interface (SSI) bus.  
5. Unmanaged Serial. The device can be configured by EEPROM using an I²C interface at bootup, or via a syn-  
chronous serial interface (SSI) otherwise. All configuration registers and internal control blocks are accessible  
by the interface. However, the CPU cannot receive or transmit frames nor will it receive any interrupt informa-  
tion.  
The CPU interface provides for easy and effective management of the switching system.  
29  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Figure 4 on page 30 provides an overview of the 8/16-bit interface. Figure 5 on page 31 provides an overview of the  
SSI interface. Figure 6 on page 32 provides an overview of the SSI+MII interface.  
Processor  
3-bit Address  
Bus  
8/16-bit DataBus  
Address  
I/ODataMUX  
Control  
Command2  
Reg  
Index Reg1  
(Addr = 1,  
8-bit only )  
Conf igData  
Reg  
(Addr = 2)  
Command/  
StatusReg  
(Addr = 4)  
ControlCommand  
1Reg  
Index Reg0  
(Addr = 0)  
CPUFrameReg  
(Addr = 3)  
InterruptReg  
(Addr = 5)  
(Addr = 6)  
(Addr = 7)  
8/16-bit Data Bus  
16-bitAddress  
8-bit Data Bus  
8/16-bit Data Bus  
Control  
Uf rame  
Internal  
Registers  
Inderect  
Access  
ControCommand1  
Control  
Command2  
Transmit  
FIFO  
nsmit  
CPUf rame  
Comman
Receiv
FIFO  
Transmit  
FIFO  
IFO  
Receiv e  
FIFO  
Interrupt  
Figure 4 - Overview of the 8/16-bit Interface  
30  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Processor  
SerialOut SerialIn  
Strobe Interrupt  
Synchronous SerialInterface  
3-bit Address Bus  
16-bit DataBus  
INTCSWR  
Address  
I/ODataMUX  
Control  
ConfigData  
Reg  
(Addr = 2)  
Command/  
StatusReg  
(Addr = 4)  
ControlCommand  
1Reg  
Index Reg0  
(Addr = 0)  
CPUFrameReg  
(Addr = 3)  
InterruptReg  
(Addr = 5)  
Command2  
Reg  
(Addr = 6)  
(Addr = 7)  
8/16-bit Data Bus  
8-bit Data Bus  
8/16-bit Data Bus  
16-bitAddress  
Control  
Uframe  
Internal  
Registers  
Inderect  
Access  
Contro
Control  
Command2  
Transmit  
FIFO  
Command1  
nsmit  
CPUframe  
Comma
Receiv
FIFO  
Transmit  
FIFO  
IFO  
Receive  
FIFO  
Interrupt  
Figure 5 - Overview of the SSI Interface  
31  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Processor  
Interrupt  
Tclk Txd Txen  
MII Interf ac e  
Rxd Rxdv Rclk  
SerialOut SerialIn  
Strobe  
Synchronous Serial Interface  
3-bit Address Bus  
16-bit Data Bus  
INTCSW R  
Address  
I/O DataMUX  
Control  
Command2  
Reg  
Conf igData  
Reg  
Command/  
StatusReg  
(Addr = 4)  
ControlCommand  
1 Reg  
Index Reg 0  
(Addr = 0)  
InterruptReg  
(Addr = 5)  
(Addr = 2)  
(Addr = 6)  
(Addr = 7)  
8-bit Data Bus  
8/16-bit Data Bus  
Control  
16-bitAddress  
Uf rame  
Internal  
Registers  
Inderect  
Access  
Contro
Control  
Command2  
Transmit  
FIFO  
Command1  
nsmit  
CPUf rame  
Comman
Receiv
FIFO  
Transmit  
FIFO  
IFO  
Receiv e  
FIFO  
Interrupt  
Figure 6 - Overview of the SSI+MII Interface  
3.1 Register Configuration, Frame Transmission and Frame Reception  
3.1.1 Register Configuration  
The ZL50409 has many programmable parameters, covering such functions as QoS weights, VLAN control, and  
port mirroring setup. In managed mode, the CPU interface provides an easy way of configuring these parameters.  
The parameters are contained in 8-bit configuration registers. The device allows indirect access to these registers,  
as follows:  
If operating in 8-bit interface mode, two “index” registers (addresses 000b and 001b) need to be written, to  
indicate the desired 16-bit register address. In 16-bit mode, only one register (address 000b) needs to be  
written for the desired 16-bit register address.  
In serial mode, the address, command and data are shifted in serially. To access the configuration registers,  
only one “index” register (addresses 000b) needs to be written with the configuration register address. The  
desired data can be written into or read from the “data” register (address 010b).  
For example, if “XX” is required to be written to register “YY”, a write of “YY” is required to write to  
address “000b” (Index register). Then, a write of “XX” is required to write to address “010b” (Data  
Register). This completes the register write and register “YY” will contain the value of “XX”.  
32  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
To indirectly configure the register addressed by the index register(s), a “data” register (address 010b) must  
be written with the desired 8-bit data.  
The ZL50409 supports special register-write in serial and 16-bit mode. This allows CPU to write to two  
consecutive configuration registers in a single write operation. By writing to bit[14] of configuration  
register address, CPU can write 16-bit data to address 010b. Lower 8 bit of data is for the address  
specified in index register and upper 8 bit of data is for the address + 1. In 8-bit mode, this special feature  
will be ignored.  
15  
14  
0
13  
12  
11  
INC  
SP  
W
Reserved  
12 Bit Register Address  
R/W  
Similarly, to read the value in the register addressed by the index register(s), the “data” register can now  
simply be read.  
The ZL50409 supports an incremental read/write. If CPU requires to read or write to the configuration  
registers incrementally, CPU only has to write to index register once with the MSB of configuration register  
address set and then CPU can continuously reading or writing to “data” register (010b).  
In summary, access to the many internal registers is carried out simply by directly accessing only two registers –  
one register to indicate the index of the desired parameter, and one register to read or write a value. Of course,  
because there is only one bus master, there can never be any conflict between reading and writing the  
configuration registers.  
3.1.2 Rx/Tx of Standard Ethernet Frames  
In serial mode with MII, the MII interface is used for CPU to transmit and receive Ethernet frames. In 8/16-bit or  
serial only mode, the Ethernet frame is transmitted and received through the CPU interface. There is no ability to  
send/receive Ethernet frames in unmanaged mode.  
To transmit a frame from the CPU in 8/16-bit or serial only mode:  
The CPU writes to the “data frame” register (address 011) with the frame size, destination port number, and  
frame status. After writing all the transmitting status bytes, it then writes the data it wants to transmit  
(minimum 64 bytes).  
The ZL50409 forwards the Ethernet frame to the desired destination port, no longer distinguishing the fact  
that the frame originated from the CPU.  
To receive a frame into the CPU in 8/16-bit or serial only mode:  
The CPU receives an interrupt when an Ethernet frame is available to be received.  
Frame information arrives first in the data frame register. This includes source port number, frame size, and  
VLAN tag.  
The actual data follows the frame information. The CPU uses the frame size information to read the frame  
out.  
To transmit a frame from the CPU with MII interface:  
ZL50409 acts as a PHY to provide receive clock (RXCLK) to CPU so the CPU will depend on this receive  
clock to send packets to ZL50409  
ZL50409 has the ability to halt the receive clock if the receive FIFO of ZL50409 is overflow. Transmitting from  
CPU to ZL50409 will resume once the receive FIFO of ZL50409 is no longer overflow  
Follow the standard Ethernet transmission format. CPU assert receive data valid (RXDV) before transmitting  
data to ZL50409 and de-assert RXDV after transmitting the last data  
To receive a frame into the CPU with MII interface:  
ZL50409 acts as a PHY to provide transmit clock (TXCLK) to CPU so the CPU will depend on the transmit  
clock to receive packets from ZL50409  
ZL50409 has the ability to halt the transmit clock if the transmit FIFO of ZL50409 is under-run. CPU will  
resume receiving packets from ZL50409 once the transmit FIFO of ZL50409 is no longer under-run  
33  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Follow the standard Ethernet transmission format. CPU will see transmit enable (TXEN) be asserted by  
ZL50409 and CPU can start receiving data. CPU will stop receiving data once TXEN is de-asserted by  
ZL50409.  
In summary, in 8/16-bit or serial only mode, receiving and transmitting frames to and from the CPU is a simple  
process that uses one direct access register only. In serial mode with MII interface, the CPU will be allowed to  
transmit and receive frames using standard IEEE 802.3 Ethernet transmission format.  
The details of sending an Ethernet Frame via the CPU interface is described in the Processor Interface Application  
Note, ZLAN-26.  
3.1.3 Control Frames  
In addition to standard Ethernet frames described in the preceding section, the CPU is also called upon to handle  
special “Control frames,” generated by the ZL50409 and sent to the CPU. These proprietary frames are related to  
such tasks as statistics collection, MAC address learning, and aging, etc. All Control frames are up to 40 bytes long.  
Transmitting and receiving these frames is similar to transmitting and receiving Ethernet frames, except that the  
register accessed is the “Control frame data” register (address 111).  
Specifically, there are the following types of control frames generated by the CPU and sent to the ZL50409:  
Memory read request  
Memory write request  
Learn Unicast MAC address  
Delete Unicast MAC address  
Search Unicast MAC address  
Learn IP Multicast address  
Delete IP Multicast address  
Search IP Multicast address  
Learn Multicast MAC address  
Delete Multicast MAC address  
Search Multicast MAC address  
Note: Memory read and write requests by the CPU may include all internal memories which include statistic  
counters, MAC address control link table and the 2 Mbit (256 KB) memory block.  
In addition, the following types of Control frames are generated by the ZL50409 and sent to the CPU:  
Interrupt CPU when statistics counter rolls over  
Response to memory read request from CPU  
Learn Unicast MAC address  
Delete Unicast MAC address  
Delete Multicast MAC address  
Delete IP Multicast address  
Response to search Unicast MAC address request from CPU  
Response to search IP Multicast address request from CPU  
Response to search Multicast MAC address request from CPU  
The format of the Control Frame is described in the Processor Interface application note, ZLAN-26.  
3.2 I2C Interface  
The I²C interface serves the function of configuring the ZL50409 at boot time. The master is the ZL50409, and the  
slave is the EEPROM memory.  
The I²C interface uses two bus lines, a serial data line (SDA) and a serial clock line (SCL). The SCL line carries the  
control signals that facilitate the transfer of information from EEPROM to the switch. Data transfer is 8-bit serial and  
bidirectional, at 50 Kbps. Data transfer is performed between master and slave IC using a request /  
34  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
acknowledgment style of protocol. The master IC generates the timing signals and terminates data transfer. Figure  
7 depicts the data transfer format. The slave address is the memory address of the EEPROM. Refer to “ZL50409  
Register Description” on page 62 for I²C address for each register.  
START  
SLAVE ADDRESS  
R/W  
ACK  
DATA 1 (8bits)  
ACK  
DATA 2  
ACK  
DATA M  
ACK  
STOP  
Figure 7 - Data Transfer Format for I²C Interface  
3.2.1 Start Condition  
Generated by the master (in our case, the ZL50409). The bus is considered to be busy after the Start condition is  
generated. The Start condition occurs if while the SCL line is High, there is a High-to-Low transition of the SDA line.  
Other than in the Start condition (and Stop condition), the data on the SDA line must be stable during the High  
period of SCL. The High or Low state of SDA can only change when SCL is Low. In addition, when the I²C bus is  
free, both lines are High.  
3.2.2 Address  
The first byte after the Start condition determines which slave the master will select. The slave in our case is the  
EEPROM. The first seven bits of the first data byte make up the slave address.  
3.2.3 Data Direction  
The eighth bit in the first byte after the Start condition determines the direction (R/W) of the message. A master  
transmitter sets this bit to W; a master receiver sets this bit to R.  
3.2.4 Acknowledgment  
Like all clock pulses, the acknowledgment-related clock pulse is generated by the master. However, the transmitter  
releases the SDA line (High) during the acknowledgment clock pulse. Furthermore, the receiver must pull-down the  
SDA line during the acknowledge pulse so that it remains stable Low during the High period of this clock pulse. An  
acknowledgment pulse follows every byte transfer.  
If a slave receiver does not acknowledge after any byte, then the master generates a Stop condition and aborts the  
transfer.  
If a master receiver does not acknowledge after any byte, then the slave transmitter must release the SDA line to let  
the master generate the Stop condition.  
3.2.5 Data  
After the first byte containing the address, all bytes that follow are data bytes. Each byte must be followed by an  
acknowledge bit. Data is transferred MSB first.  
3.2.6 Stop Condition  
Generated by the master. The bus is considered to be free after the Stop condition is generated. The Stop condition  
occurs if while the SCL line is High, there is a Low-to-High transition of the SDA line.  
3.3 Synchronous Serial Interface  
The synchronous serial interface (SSI) serves the function of configuring the ZL50409 not at boot time but via a PC.  
The PC serves as master and the ZL50409 serves as slave. The protocol for the synchronous serial interface is  
nearly identical to the I²C protocol. The main difference is that there is no acknowledgment bit after each byte of  
data transferred. Debounce logic on the clock signal (STROBE) can be turned off to speedup command time.  
35  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
3 ID bits are used to allow up to eight ZL50409 devices to share the same synchronous serial interface. The ID of  
each device can be setup by bootstrap.  
To reduce the number of signals required, the register address, command and data are shifted in serially through  
the DATAIN pin. STROBE- pin is used as the shift clock. DATAOUT pin is used as data return path.  
Each command consists of four parts.  
START pulse  
Register Address  
Read or Write command  
Data to be written or read back  
Write operation can be aborted in the middle by sending an ABORT pulse to the ZL50409. Read operation can only  
be aborted before issuing the read command to the ZL50409.  
A START command is detected when DATAIN is sampled high when STROBE- rise and DATAIN is sampled low  
when STROBE- fall.  
An ABORT command is detected when DATAIN is sampled low when STROBE- rise and DATAIN is sampled high  
when STROBE- fall.  
3.3.1 Write Command  
All registers in ZL50409 can be modified through this synchronous serial interface. Once the data has been sent,  
two extra STOBE clocks must be generated to indicate the end of the write command. The DATAIN line is ignored  
for these two pulses.  
STROBE  
2 Extra clocks after last  
transfer  
DATAIN  
ID0 ID1 ID2 A0  
START ID  
A1  
A2  
W
D0  
D1  
D2  
D3  
...  
D12 D13 D14 D15  
ADDR  
CMD  
DATA  
Figure 8 - Serial Interface Write Command Functional Timing  
3.3.2 Read Command  
All registers in ZL50409 can be read through this synchronous serial interface.  
STROBE  
DATAIN  
ID0 ID1 ID2  
ID  
A0  
A1 A2  
ADDR  
R
START  
DATAOUT  
CMD  
DATA  
...  
D0  
D1  
D2  
D12 D13 D14 D15  
Figure 9 - Serial Interface Read Command Functional Timing  
36  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
4.0 Data Forwarding Protocol  
4.1 Unicast Data Frame Forwarding  
When a frame arrives, it is assigned a handle in memory by the Frame Control Buffer Manager (FCB Manager). An  
FCB handle will always be available, because of advance buffer reservations.  
The memory (SRAM) interface is a 64-bit bus, connected to internal memory block. The Receive DMA (RxDMA) is  
responsible for multiplexing the data and the address. On a port’s “turn”, the RxDMA will move 8 bytes (or up to the  
end-of-frame) from the port’s associated RxFIFO into memory (Frame Data Buffer, or FDB).  
Once an entire frame has been moved to the FDB, and a good end-of-frame (EOF) has been received, the Rx  
interface makes a switch request. The RxDMA arbitrates among multiple switch requests.  
The switch request consists of the first 64 bytes of a frame, containing among other things, the source and  
destination MAC addresses of the frame. The search engine places a switch response in the switch response  
queue of the frame engine when done. Among other information, the search engine will have resolved the  
destination port of the frame and will have determined that the frame is unicast.  
After processing the switch response, the Transmission Queue Manager (TxQ manager) of the frame engine is  
responsible for notifying the destination port that it has a frame to forward. But first, the TxQ manager has to decide  
whether or not to drop the frame, based on global FDB reservations and usage, as well as TxQ occupancy at the  
destination. If the frame is not dropped, then the TxQ manager links the frame’s FCB to the correct  
per-port-per-class TxQ. The switch response will come with 8 classified results. The TxQ manager will map this  
result into the per-port-per-class queue. Unicast TxQ’s are linked lists of transmission jobs, represented by their  
associated frames’ FCB’s. There is one linked list for each transmission class for each port. There are 2  
transmission classes for each of the 8 RMAC ports, and 4 classes for the MMAC and CPU ports – a total of 24  
unicast queues.  
The TxQ manager is responsible for scheduling transmission among the queues representing different classes for a  
port. When the port control module determines that there is room in the MAC Transmission FIFO (TxFIFO) for  
another frame, it requests the handle of a new frame from the TxQ manager. The TxQ manager chooses among  
the head-of-line (HOL) frames from the per-class queues for that port, using a Zarlink Semiconductor scheduling  
algorithm.  
The Transmission DMA (TxDMA) is responsible for multiplexing the data and the address. On a port’s turn, the  
TxDMA will move 8 bytes (or up to the EOF) from memory into the port’s associated TxFIFO. After reading the EOF,  
the port control requests a FCB release for that frame. The TxDMA arbitrates among multiple buffer release  
requests.  
The frame is transmitted from the TxFIFO to the line.  
4.2 Multicast Data Frame Forwarding  
The search engine will resolve the destination ports of the multicast frame. This will be all ports within the VLAN (L2  
multicast), or the ports contained in the portmap of the learned multicast MAC address or IP multicast group. After  
receiving the switch response, the TxQ manager has to make the dropping decision. A global decision to drop can  
be made, based on global FDB utilization and reservations. If so, then the FCB is released and the frame is  
dropped.  
In addition, a selective decision to drop can be made, based on the TxQ occupancy at some subset of the multicast  
packet’s destinations. If so, then the frame is dropped at some destinations but not others, and the FCB is not  
released.  
If the frame is not dropped at a particular destination port, then the TxQ manager formats an entry in the multicast  
queue for that port and class. Multicast queues are physical queues (unlike the linked lists for unicast frames).  
There are 2 multicast queues for each of the 8 RMAC ports. There are 4 multicast queues for the MMAC and CPU  
ports. The mapping from the classified result to the priority queue is the same as the unicast traffic. By default, for  
the RMAC ports to map the 8 transmit priorities into 2 multicast queues, the 2 LSB are discarded. For the MMAC  
37  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
and CPU ports, to map the 8 transmit priorities into 4 multicast queues, the LSB is discarded. The priority mapping  
can be modified through memory configuration command. The multicast queue that is in FIFO format shares the  
space in the internal memory block. The size and starting address can also be programmed through memory  
configuration command.  
During scheduling, the TxQ manager treats the unicast queue and the multicast queue of the same class as one  
logical queue. The older head of line of the two queues is forwarded first. The port control requests a FCB release  
only after the EOF for the multicast frame has been read by all ports to which the frame is destined.  
4.3 Frame Forwarding To and From CPU  
Frame forwarding from the CPU port to a regular transmission port is nearly the same as forwarding between  
transmission ports. The only difference is that the physical destination port must be indicated in addition to the  
destination MAC address.  
Frame forwarding to the CPU port is nearly the same as forwarding to a regular transmission port. The only  
difference is in frame scheduling. Instead of using the patent-pending Zarlink Semiconductor scheduling algorithms,  
scheduling for the CPU port is simply based on strict priority. That is, a frame in a high priority queue will always be  
transmitted before a frame in a lower priority queue. There are four output queues to the CPU and one receive  
queue.  
5.0 Search Engine  
5.1 Search Engine Overview  
The ZL50409 search engine is optimized for high throughput searching, with enhanced features to support:  
Up to 4 K of Unicast/Multicast MAC addresses and IP Multicast addresses  
Up to 4 K VLANs  
Up to 8 groups of port trunking  
Traffic classification into 2 (or 4 for MMAC) transmission priorities, and 2 drop precedence levels  
Packet filtering based on MAC address, Protocol or Logical Port number  
Security  
Up to 4 K IP Multicast groups  
Individual Flooding, Broadcast, Multicast Storm Control  
MAC address learning and aging  
5.2 Basic Flow  
Shortly after a frame enters the ZL50409 and is written to the Frame Data Buffer (FDB), the frame engine generates  
a Switch Request, which is sent to the search engine. The switch request consists of the first 64 bytes of the frame,  
which contain all the necessary information for the search engine to perform its task. When the search engine is  
done, it writes to the Switch Response Queue, and the frame engine uses the information provided in that queue for  
scheduling and forwarding.  
In performing its task, the search engine extracts and compresses the useful information from the 64-byte switch  
request. Among the information extracted are the source and destination MAC addresses, the packet’s VLAN ID,  
and whether the frame is unicast or multicast or broadcast. Requests are sent to the SRAM to locate the associated  
entries in the MCT table.  
When all the information has been collected from the SRAM, the search engine has to compare the MAC address  
on the current entry with the MAC address for which it is searching. If it is not a match, the process is repeated on  
the internal MCT Table. All MCT entries other than the first of each linked list are maintained internal to the chip. If  
the desired MAC address is still not found, then the result is either learning (source MAC address unknown) or  
flooding (destination MAC address unknown).  
38  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
In addition, VLAN information is used to select the correct set of destination ports for the frame (for multicast), or to  
verify that the frame’s destination port is associated with the VLAN (for unicast).  
If the destination MAC address belongs to a port trunk, then the trunk number is retrieved instead of the port  
number. The selection of the port within the trunk that will transmit the frame is computed using a hash of the  
source and/or destination MAC addresses.  
When all the information is compiled, the switch response is generated, as stated earlier. The search engine also  
interacts with the CPU with regard to learning and aging.  
5.3 Search, Learning and Aging  
5.3.1 MAC Search  
The search block performs source MAC address and destination MAC address (or destination IP address for IP  
multicast) searching. As we indicated earlier, if a match is not found, then the next entry in the linked list must be  
examined, and so on until a match is found or the end of the list is reached.  
In tag-based VLAN mode, if the frame is unicast, and the frame's destination port is recognized as a member of the  
VLAN, then the frame is forwarded to that port; otherwise, the frame is forwarded to all the members in the VLAN  
domain. If the frame is multicast or broadcast, the frame is forwarded to all the members in the VLAN, or those  
ports in the learned mulicast MAC address’s or IP multicast group’s portmap.  
In port based VLAN mode, a bit map is used to determine whether the frame should be forwarded to the outgoing  
port. The main difference in this mode is that the bit map is not dynamic. Ports cannot enter and exit groups  
because of real-time learning made by a CPU.  
The MAC search block is also responsible for updating the source MAC address timestamp used for aging.  
Moreover, if port trunking is enabled, this block selects the destination port (among those in the trunk group).  
5.3.2 Learning  
The learning module learns new MAC addresses and performs port change operations on the MCT database. The  
goal of learning is to update this database as the networking environment changes over time.  
When CPU reporting is enabled, learning and port change will be performed when the CPU request queue has  
room, and a “Learn MAC Address” message is sent to the CPU.  
5.3.3 Aging  
Aging time is controlled by register 400h and 401h.  
The aging module scans and ages MCT entries based on a programmable “age out” time interval. As we indicated  
earlier, the search module updates the source MAC address timestamps for each frame it processes. When an  
entry is ready to be aged, the entry is removed from the table, and a “Delete MAC Address” message is sent to  
inform the CPU.  
Supported MAC entry types are: dynamic, static, multicast, source filter, destination filter, source and destination  
filter, and secure MAC addresses. The only supported IP entry type is IP multicast. Only dynamic entries can be  
aged; all others are static. The entry type is stored in the “status” field of the MCT data structure.  
5.4 MAC Address Filtering  
The ZL50409's implementation of intelligent traffic switching provides filters for source and destination MAC  
addresses. This feature filters unnecessary traffic, thereby providing intelligent control over traffic flows and  
broadcast traffic.  
Broadcast, unknown unicast or unknown multicast MAC address can also be filter on per VLAN basis.  
39  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
MAC address filtering allows the ZL50409 to block an incoming packet to an interface when it sees a specified MAC  
address in either the source address or destination address of the incoming packet. For example, if your network is  
congested because of high utilization from a MAC address, you can filter all traffic transmitted from that address  
and restore network flow, while you troubleshoot the problem.  
5.5 Protocol Filtering  
Packet filtering can be performed based on protocol type field in the packets. Up to eight protocols can be  
programmed to filter or allow packet to pass through the switch.  
5.6 Logical Port Filtering  
Similar to protocol filtering, if the packet’s logical ports match the programmable registers, the packet can be filtered  
or passed through the switch. Up to eight programmable ports and one ranges can be assigned.  
5.7 Quality of Service  
Quality of Service (QoS) refers to the ability of a network to provide better service to selected network traffic over  
various technologies. Primary goals of QoS include dedicated bandwidth, controlled jitter and latency (required by  
some real-time and interactive traffic), and improved loss characteristics.  
Traditional Ethernet networks have had no prioritization of traffic. Without a protocol to prioritize or differentiate  
traffic, a service level known as “best effort” attempts to get all the packets to their intended destinations with  
minimum delay; however, there are no guarantees. In a congested network or when a low-performance  
switch/router is overloaded, “best effort” becomes unsuitable for delay-sensitive traffic and mission-critical data  
transmission.  
The advent of QoS for packet-based systems accommodates the integration of delay-sensitive video and  
multimedia traffic onto any existing Ethernet network. It also alleviates the congestion issues that have previously  
plagued such “best effort” networking systems. QoS provides Ethernet networks with the breakthrough technology  
to prioritize traffic and ensure that a certain transmission will have a guaranteed minimum amount of bandwidth.  
Extensive core QoS mechanisms are built into the ZL50409 architecture to ensure policy enforcement and  
buffering of the ingress port, as well as weighted fair-queue (WFQ) scheduling at the egress port.  
In the ZL50409, QoS-based policies sort traffic into a small number of classes and mark the packets accordingly.  
The QoS identifier provides specific treatment to traffic in different classes, so that different quality of service is  
provided to each class. Frame and packet scheduling and discarding policies are determined by the class to which  
the frames and packets belong. For example, the overall service given to frames and packets in the premium class  
will be better than that given to the standard class; the premium class is expected to experience lower loss rate or  
delay.  
The ZL50409 supports the following QoS techniques:  
In a port-based setup, any station connected to the same physical port of the switch will have the same  
transmit priority.  
In a tag-based setup, a 3-bit field in the VLAN tag provides the priority of the packet. This priority can be  
mapped to different queues in the switch to provide QoS.  
In a TOS/DS-based set up, TOS stands for “Type of Service” that may include “minimize delay,” “maximize  
throughput,” or “maximize reliability.” Network nodes may select routing paths or forwarding behaviours that  
are suitably engineered to satisfy the service request.  
In a logical port-based set up, a logical port provides the application information of the packet. Certain  
applications are more sensitive to delays than others; using logical ports to classify packets can help speed  
up delay sensitive applications, such as VoIP.  
40  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
5.8 Priority Classification Rule  
Figure 10 shows the ZL50409 priority classification rule.  
Yes  
Fix Port Priority?  
Use Default port settings  
No  
TOS Precedence over VLAN?  
Yes  
(QOSC Register bit 5)  
No  
Yes  
No  
Use VLAN  
priority  
VLAN Tag?  
IP Frame?  
No  
Yes  
Yes  
No  
IP Frame?  
Use Logical Port?  
Use TOS  
No  
Yes  
Use Default port settings  
Use logical port  
Figure 10 - Priority Classification Rule  
5.9 Port and Tag Based VLAN  
The ZL50409 supports two models for determining and controlling how a packet gets assigned to a VLAN: port  
priority and tag -based VLAN.  
5.9.1 Port-Based VLAN  
An administrator can use the PVMAP Registers to configure the ZL50409 for port-based VLAN (see “Register  
Definition” on page 62). For example, ports 1-3 might be assigned to the Marketing VLAN, ports 4-6 to the  
Engineering VLAN, and ports 7-9 to the Administrative VLAN. The ZL50409 determines the VLAN membership of  
each packet by noting the port on which it arrives. From there, the ZL50409 determines which outgoing port(s)  
is/are eligible to transmit each packet, or whether the packet should be discarded.  
41  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Destination Port Numbers Bit Map  
Port Registers  
9
0
2
1
1
1
0
0
Register for Port #0  
PVMAP00_0[7:0] to PVMAP00_1[1:0]  
Register for Port #1  
0
0
1
0
0
0
1
0
PVMAP01_0[7:0] to PVMAP01_1[1:0]  
Register for Port #2  
PVMAP02_0[7:0] to PVMAP02_1[1:0]  
Register for Port #9  
0
0
0
0
PVMAP09_0[7:0] to PVMAP09_1[1:0]  
Table 7 - Port-Based VLAN Mapping  
For example, in the above table a 1 denotes that an outgoing port is eligible to receive a packet from an incoming  
port. A 0 (zero) denotes that an outgoing port is not eligible to receive a packet from an incoming port.  
In this example:  
Data packets received at port #0 are eligible to be sent to outgoing ports 1 and 2.  
Data packets received at port #1 are eligible to be sent to outgoing ports 0 and 2.  
Data packets received at port #2 are NOT eligible to be sent to ports 0 and 1.  
5.9.2 Tag-Based VLAN  
The ZL50409 supports the IEEE 802.1q specification for “tagging” frames. The specification defines a way to  
coordinate VLANs across multiple switches. In the specification, an additional 4-octet header (or “tag”) is inserted in  
a frame after the source MAC address and before the frame type. 12 bits of the tag are used to define the VLAN ID.  
Packets are then switched through the network with each ZL50409 simply swapping the incoming tag for an  
appropriate forwarding tag rather than processing each packet's contents to determine the path. This approach  
minimizes the processing needed once the packet enters the tag-switched network. In addition, coordinating VLAN  
IDs across multiple switches enables VLANs to extend to multiple switches.  
Up to 4 K VLANs are supported in the ZL50409. When tag-based VLAN is enabled, each MAC address is learned  
with it associated VLAN.  
See IEEE 802.1Q VLAN Setup application note, ZLAN-51, for more information.  
5.9.3 VLAN Stacking (Q-in-Q)  
The ZL50409 partially supports VLAN stacking, also called IEEE 802.1Q-in-Q. This technology allows an additional  
VLAN tag, called a provider VLAN tag, to be inserted into an existing IEEE 802.1Q tagged Ethernet frame. This  
technology has been widely adapted in Metro Ethernet applications since it provides a very cost-effective solution  
to transport multiple customers' VLAN across the service provider's MAN/WAN without interfering each other. The  
below figure illustrates the IEEE 802.1Q frame and the Q-in-Q frame, where the provider VLAN tag is inserted in  
front of the IEEE 802.1Q tag.  
42  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
IEEE 802.1Q Tagged  
Ethernet Frame  
IEEE  
802.1Q Tag  
VLAN  
Dest MAC  
(6 Bytes)  
Source MAC  
(6 Bytes)  
VLAN TCI  
(2 Bytes)  
Type/Length  
(2 Byte)  
Tag Protocol ID  
Data  
(0x8100)  
Provider  
IEEE 802.1Q-in-Q Tagged  
Ethernet Frame  
Tag  
(P-VLAN)  
IEEE  
802.1Q Tag  
VLAN  
VLAN  
Dest MAC  
(6 Bytes)  
Source MAC  
(6 Bytes)  
VLAN TCI  
(2 Bytes)  
VLAN TCI  
(2 Bytes)  
Type/Length  
(2 Byte)  
Tag Protocol ID  
Tag Protocol ID  
(0x8100)  
Data  
(0x88A8*)  
IEEE 802.1Q Tag TPID = 0x8100  
* Provider Tag TPID = Configurable on per device basis  
Figure 11 - Q-in-Q Tagged Ethernet Frame  
The value of the TPID of the Provider VLAN tag is not assigned in the IEEE 802.1ad standard. The ZL50409  
provides a global configurable TPID but only supports the Extreme EtherType TPID (i.e. the stacked VLAN tag  
cannot equal 0x81-00).  
See Stacked VLAN application note, ZLAN-82, for more information.  
5.10 IP Multicast Switching  
The ZL50409 supports IP Multicast Filtering by:  
Passively snooping on the IGMP Query and IGMP Report packets transferred between IP Multicast Routers  
and IP Multicast host groups to learn IP Multicast group members, and  
Actively sending IGMP Query messages to solicit IP Multicast group members.  
The purpose of IP multicast filtering is to optimize a switched network performance, so multicast packets will only  
be forwarded to those ports containing multicast group hosts members and routers instead of flooding to all ports in  
the subnet (VLAN).  
The ZL50409 with IP multicast filtering/switching capability not only passively monitor IGMP Query and Report  
messages, DVMRP Probe messages, PIM, and MOSPF Hello messages; they also actively send IGMP Query  
messages to learn locations of multicast routers and member hosts in multicast groups within each VLAN.  
See IP Multicast Switching application note, ZLAN-52, for more information.  
5.11 L2 Multicast Switching  
The ZL50409 supports multicast MAC address learning when in tagged-based VLAN mode. The purpose of  
multicast MAC learning is to optimize a L2 switched network performance, so multicast packets will only be  
forwarded to those ports configured to receive that multicast traffic instead of flooding to all ports within the VLAN.  
6.0 Frame Engine  
6.1 Data Forwarding Summary  
When a frame enters the device at the RxMAC, the RxDMA will move the data from the MAC RxFIFO to the FDB.  
Data is moved in 8-byte granules in conjunction with the scheme for the SRAM interface.  
43  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
A switch request is sent to the Search Engine. The Search Engine processes the switch request.  
A switch response is sent back to the Frame Engine and indicates whether the frame is unicast or multicast, and its  
destination port or ports. On receiving the response, the Frame Engine will check all the QoS related information  
and decide if this frame can be forwarded.  
A Transmission Scheduling Request is sent in the form of a signal notifying the TxQ manager. Upon receiving a  
Transmission Scheduling Request, the device will format an entry in the appropriate Transmission Scheduling  
Queue (TxSch Q) or Queues. There are 2 TxSch Q for each RMAC port (and 4 per MMAC and CPU ports), one  
for each priority. Creation of a queue entry either involves linking a new job to the appropriate linked list if unicast,  
or adding an entry to a physical queue if multicast.  
When the port is ready to accept the next frame, the TxQ manager will get the head-of-line (HOL) entry of one of  
the TxSch Qs, according to the transmission scheduling algorithm (so as to ensure per-class quality of service).  
(The unicast linked list and the multicast queue for the same port-class pair are treated as one logical queue. The  
older HOL between the two queues goes first.  
The TxDMA will pull frame data from the memory and forward it granule-by-granule to the MAC TxFIFO of the  
destination port.  
6.2 Frame Engine Details  
This section briefly describes the functions of each of the modules of the ZL50409 frame engine.  
6.2.1 FCB Manager  
The FCB manager allocates FCB handles to incoming frames, and releases FCB handles upon frame departure.  
The FCB manager is also responsible for enforcing buffer reservations and limits that will be used for QoS control  
and source port flow control. The default values can be determined by referring to Section 7.6 on page 47. The  
frame buffer is managed in a 128bytes block unit. During initialization, this block will link all the available blocks in a  
free buffer list. When each port is ready to receive, this module hands the buffer handle to each requesting port.  
The FCB manager will also link the released buffer back into the free buffer list.  
The maximum buffer size can be increased from the standard 1518 bytes (1522 with VLAN tag) to up to 4 K bytes.  
This is done using BUF_LIMIT, and is enabled on a per port basis via bit [1] in ECR3Pn. See Buffer Allocation  
application note, ZLAN-47, for more information.  
6.2.2 Rx Interface  
The Rx interface is mainly responsible for communicating with the RxMAC. It keeps track of the start and end of  
frame and frame status (good or bad). Upon receiving an end of frame that is good, the Rx interface makes a switch  
request.  
6.2.3 RxDMA  
The RxDMA arbitrates among switch requests from each Rx interface. It also buffers the first 64 bytes of each  
frame for use by the search engine when the switch request has been made.  
6.2.4 TxQ Manager  
First, the TxQ manager checks the per-class queue status and global reserved resource situation, and using this  
information, makes the frame dropping decision after receiving a switch response. The dropping decision includes  
the head-of-link blocking avoidance if the source port is not flow control enabled. If the decision is not to drop, the  
TxQ manager links the unicast frame’s FCB to the correct per-port-per-class TxQ and updates the FCB information.  
If multicast, the TxQ manager writes to the multicast queue for that port and class and also update the FCB  
information including the duplicate count for this multicast frame. The TxQ manager can also trigger source port  
flow control for the incoming frame’s source if that port is flow control enabled. Second, the TxQ manager handles  
transmission scheduling; it schedules transmission among the queues representing different classes for a port.  
44  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Once a frame has been scheduled, the TxQ manager reads the FCB information and writes to the correct port  
control module. The detail of the QoS decision guideline is described in chapter 5.  
6.2.5 Port Control  
The port control module calculates the SRAM read address for the frame currently being transmitted. It also writes  
start of frame information and an end of frame flag to the MAC TxFIFO. When transmission is done, the port control  
module requests that the buffer be released.  
6.2.6 TxDMA  
The TxDMA multiplexes data and address from port control, and arbitrates among buffer release requests from the  
port control modules.  
7.0 Quality of Service and Flow Control  
7.1 Model  
Quality of service is an all-encompassing term for which different people have different interpretations. In general,  
the approach to quality of service described here assumes that we do not know the offered traffic pattern. We also  
assume that the incoming traffic is not policed or shaped. Furthermore, we assume that the network manager  
knows his applications, such as voice, file transfer, or web browsing, and their relative importance. The manager  
can then subdivide the applications into classes and set up a service contract with each. The contract may consist  
of bandwidth or latency assurances per class. Sometimes it may even reflect an estimate of the traffic mix offered to  
the switch. As an added bonus, although we do not assume anything about the arrival pattern, if the incoming traffic  
is policed or shaped, we may be able to provide additional assurances about our switch’s performance.  
A class is capable of offering traffic that exceeds the contracted bandwidth. A well-behaved class offers traffic at a  
rate no greater than the agreed-upon rate. By contrast, a misbehaving class offers traffic that exceeds the  
agreed-upon rate. A misbehaving class is formed from an aggregation of misbehaving microflows. To achieve high  
link utilization, a misbehaving class is allowed to use any idle bandwidth. However, such leniency must not degrade  
the quality of service (QoS) received by well-behaved classes.  
Each traffic type may each have their own distinct properties and applications. Classes may receive bandwidth  
assurances or latency bounds. For example, the highest transmission class may require that all frames receive  
50% of the 100 Mbps of bandwidth at that port.  
Best-effort (P0) traffic forms a class that only receives bandwidth when none of the other classes have any traffic to  
offer. It is also possible to add a class that has strict priority over all others; if this class has even one frame to  
transmit, then it goes first. In the ZL50409, each RMAC port will support two total classes, and the MMAC port will  
support four classes. We will discuss the various modes of scheduling these classes in the next section.  
In addition, each transmission class has two subclasses, high-drop and low-drop. Well-behaved users should rarely  
lose packets. But poorly behaved users–users who send frames at too high a rate – will encounter frame loss, and  
the first to be discarded will be high-drop. Of course, if this is insufficient to resolve the congestion, eventually some  
low-drop frames are dropped, and then all frames in the worst case. For example, casual web browsing fits into the  
category of high-loss, high-latency-tolerant traffic, whereas VoIP fits into the category of low-loss, low-latency traffic.  
7.2 Two QoS Configurations  
There are two basic pieces to QoS scheduling in the MMAC port of ZL50409: strict priority (SP) or weighted fair  
queuing (WFQ). The only configuration for a RMAC and CPU port is strict priority between the queues.  
7.2.1 Strict Priority  
When strict priority is part of the scheduling algorithm, if a queue has any frame to transmit, it goes first. For RMAC  
ports, this is an easy way to provide the different service. For all recognizable traffic, the bandwidth is guaranteed to  
45  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
100% of the line rate. This scheme works as long as the overall high priority bandwidth is not over the line rate and  
the latency on all the low priority traffic is don’t care. The lowest priority queue is treated as “best effort” queue.  
The strict priority queue in the MMAC and CPU ports is similar to RMAC ports other than having 4 queues instead  
of 2 queues. The priority queue P0 can be scheduled only if the priority queue P1 is empty, so as to priority queues  
P2 and P3.  
Because we do not provide any assurances for “best effort” traffic, we do not enforce latency by dropping best effort  
traffic. Furthermore, because we assume that strict priority traffic is carefully controlled before entering the  
ZL50409, we do not enforce a fair bandwidth partition by dropping strict priority traffic. To summarize, dropping to  
enforce bandwidth or delay does not apply to strict priority or best effort queues. We only drop frames from best  
effort and strict priority queues when queue size is too long or global / class buffer resources become scarce.  
7.2.2 Weighted Fair Queuing  
In some environments – for example, in an environment in which delay assurances are not required, but precise  
bandwidth partitioning on small time scales is essential, WFQ may be preferable to a strict assurance scheduling  
discipline. The ZL50409 provides this kind of scheduling algorithm on MMAC port only. The user sets four WFQ  
“weights” such that all weights are whole numbers and sum to 64. This provides per-class bandwidth partitioning  
with granular within 2%.  
In WFQ mode, though we do not assure frame latency, the ZL50409 still retains a set of dropping rules that helps to  
prevent congestion and trigger higher level protocol end-to-end flow control.  
7.3 WRED Drop Threshold Management Support  
To avoid congestion, the Weighted Random Early Detection (WRED) logic drops packets according to specified  
parameters. The following table summarizes the behavior of the WRED logic.  
Px > WRED_L1  
Px > WRED_L2  
BM Reject  
High Drop  
Low Drop  
X%  
Y%  
100%  
Z%  
100%  
100%  
Table 8 - WRED Logic Behaviour  
Px is the total byte count, in the priority queue x, can be the strict priority queue of RMAC ports and higher 3 priority  
queues for MMAC port. The WRED logic has two drop levels, depending on the value of Px. Each drop level has  
defined high-drop and low-drop percentages, which indicate the minimum and maximum percentages of the data  
that can be discarded. The X, Y Z percent can be programmed by the register RDRC0, RDRC1. All packets will be  
dropped only if the system runs out of the specific buffer resource, per class buffer or per source port buffer. The  
WRED thresholds of each queue can be programmed by the QOS control registers (refer to the register group 8).  
See Programming QoS Registers application note, ZLAN-42, for more information.  
7.4 Shaper  
Although traffic shaping is not a primary function of the ZL50409, the chip does implement a shaper for every queue  
in the MMAC port. Our goal in shaping is to control the average rate of traffic exiting the ZL50409. If shaper is  
enabled, strict priority will be applied to that queue. The priority between two shaped queue is the same as in strict  
priority scheduling.  
Traffic rate is set using a programmable whole number, no greater than 64. For example, if the setting is 32, then  
the traffic rate transmit out of the shaped queue is 32/64 * 1000 Mbps = 500 Mbps. See Programming QoS Register  
application note, ZLAN-42, for more information.  
Also, when shaping is enabled, it is possible for a queue to explode in length if fed by a greedy source. The reason  
is that a shaper is by definition not work-conserving; that is, it may hold back from sending a packet even if the line  
46  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
is idle. Though we do have global resource management, we do nothing other than per port WRED to prevent this  
situation locally. We assume the traffic is policed at a prior stage to the ZL50409 or WRED dropping is fine and shall  
restrain this situation.  
7.5 Rate Control  
The ZL50409 provides a rate control function on its RMAC ports. The concept is much the same as shaping, except  
that it applies to both ingress and egress directions and the control is per port rather than per queue. It provides a  
way of reducing the total bandwidth of all frames received from or transmitted to a port, to a rate below wire speed.  
As with shaping, the maximum burst size can also be configured.  
Rate control may be a valuable feature on RMAC ports in access applications where the service provider would like  
to limit the traffic received and transmitted by each port independently of each other, and independently of the  
physical line rate. The service provider can then provide differential pricing, based on the negotiated bandwidth  
requirements for each user. In such applications of the ZL50409, the MMAC port is viewed as an uplink port, where  
rate control is not desired.  
See Rate Control application note, ZLAN-33, for more information.  
7.6 Buffer Management  
Because the number of FDB slots is a scarce resource, and because we want to ensure that one misbehaving  
source port or class cannot harm the performance of a well-behaved source port or class, we introduce the concept  
of buffer management into the ZL50409. Our buffer management scheme is designed to divide the total buffer  
space into numerous reserved regions and one shared pool, as shown in Figure 12 on page 48.  
As shown in the figure, the FDB pool is divided into several parts. A reserved region for temporary frames stores  
frames prior to receiving a switch response. Such a temporary region is necessary, because when the frame first  
enters the ZL50409, its destination port and class are as yet unknown, and so the decision to drop or not needs to  
be temporarily postponed. This ensures that every frame can be received first before subjecting them to the frame  
drop discipline after classifying.  
Three priority sections, one for each pair of the first six priority classes, ensure a programmable number of FDB  
slots per class. The lowest two classes do not receive any buffer reservation. Furthermore, a frame is stored in the  
region of the FDB corresponding to its class. As we have indicated, the eight classes use only two transmission  
scheduling queues for RMAC ports (four queues for the MMAC & CPU ports), but as far as buffer usage is  
concerned, there are still eight distinguishable classes.  
Another segment of the FDB reserves space for each of the 10 ports — 9 ports for Ethernet and one CPU port (port  
number 8). Each port has it’s own programmable source port reservation. These 10 reserved regions make sure  
that no well-behaved source port can be blocked by another misbehaving source port.  
In addition, there is a shared pool, which can store any type of frame. The frame engine allocates the frames first in  
the three priority sections. When the priority section is full or the packet has priority 1 or 0, the frame is allocated in  
the shared pool. Once the shared pool is full the frames are allocated in the section reserved for the source port.  
The following registers define the size of each section of the Frame data Buffer:  
-
-
-
-
-
-
-
PR100_N - Port Reservation for RMAC Ports  
PR100_CPU - Port Reservation for CPU Port  
PRM - Port Reservation for MMAC Port  
SFCB - Share FCB Size  
C1RS - Class 1 Reserve Size (priority 2 & 3)  
C2RS - Class 2 Reserve Size (priority 4 & 5)  
C3RS - Class 3 Reserve Size (priority 6 & 7)  
47  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Temporary reservation  
Rpri3 Shared Pool S  
Rpri1  
Rpri2  
Per Class  
Reservation  
Rp0  
Rp1  
Rp2  
Rp3  
Rp4  
Rp5  
Rp6  
Rp7  
Rp8  
Rp9  
(CPU)  
Per Source Port  
Reservation  
Figure 12 - Buffer Partition Scheme  
See Buffer Allocation application note, ZLAN-47, for more information.  
7.6.1 Dropping When Buffers Are Scarce  
As already discussed, the WRED mechanism may drop frames on output queue status. In addition to these  
reasons for dropping, we also drop frames when global buffer space becomes scarce. The function of buffer  
management is to make sure that such dropping causes as little blocking as possible.  
If a received frame is dispatched to the P0 (“best effort”) queue, the buffer management will check on the overall  
buffer situation plus the output queue status to decide the frame drop condition. If the source port has not enough  
buffer for it, the frame will be dropped. If the output queue reaches PCC (packet congest control) and the shared  
buffer has run out, the frame may be dropped by RED (at B%). If the output queue reaches PCC and the source  
port reservation is lower than the buffer low threshold, the frame will be dropped.  
For multicast frames, global thresholds are used to manage scarce resources. When a multicast frame is received,  
the buffer management will check on the overall buffer situation. If total multicast resources reaches MCCTH  
(multicast congest control threshold), the frame may be dropped by RED (at B%). If total multicast resources  
reaches MCC, the frame will be dropped.  
All the 100% dropping functions are disabled if the source port is flow control capable, however, RED (at B%) will  
still be applied.  
7.7 Flow Control Basics  
Because frame loss is unacceptable for some applications, the ZL50409 provides a flow control option. When flow  
control is enabled, scarcity of source port buffer space may trigger a flow control signal; this signal tells a source  
port sending a packet to this switch, to temporarily hold off.  
While flow control offers the clear benefit of no packet loss, it also introduces a problem for quality of service. When  
a source port receives an Ethernet flow control signal, all microflows originating at that port, well-behaved or not,  
are halted. A single packet destined for a congested output can block other packets destined for un-congested  
outputs. The resulting head-of-line blocking phenomenon means that quality of service cannot be assured with high  
confidence when flow control is enabled.  
On the other hand, the ZL50409 will still prioritize the received frame disregarding the outgoing port flow control  
capability. If a frame is classified as high priority, it is still subjected to the WRED, which means the no-loss on the  
high priority queue is not guaranteed. To resolve this situation, the user may set the output port WRED threshold so  
high that may never be reached, or program the priority mapping table in the queue manager to map all the traffic to  
“best effort” (P0) queue on the flow control capable port. The first method has side impact on the global resource  
management since the port may hold too much per class resource that is scarce in the system. The second  
method, by nature, lost the benefit of prioritization.  
48  
Zarlink Semiconductor Inc.  
ZL50409  
See Programming Flow Control Registers application note, ZLAN-44, for more information.  
7.7.1 Unicast Flow Control  
Data Sheet  
For unicast frames, flow control is triggered by source port resource availability. Recall that the ZL50409’s buffer  
management scheme allocates a reserved number of FDB slots for each source port. If a programmed number of a  
source port’s reserved FDB slots have been used, then flow control Xoff is triggered.  
Xon is triggered when a port is currently being flow controlled, and all of that port’s reserved FDB slots have been  
released.  
Note that the ZL50409’s per-source-port FDB reservations assure that a source port that sends a single frame to a  
congested destination will not be flow controlled.  
7.7.2 Multicast Flow Control  
Flow control for multicast frames is triggered by a global buffer counter. When the system exceeds a programmable  
threshold of multicast packets, Xoff is triggered. Xon is triggered when the system returns below this threshold.  
Note: If per-port flow control is on, QoS performance will be affected.  
7.8 Mapping to IETF Diffserv Classes  
The mapping between priority classes discussed in this chapter and elsewhere is shown below.  
ZL50409  
IETF  
P3  
P2  
P1  
P0  
BE  
NM+EF  
AF0  
AF1  
Table 9 - Mapping to IETF Diffserv Classes for MMAC & CPU Ports  
As the table illustrates, the classes of Table 9 are merged in pairs— P3 is used for network management (NM) and  
expedited forwarding service (EF) frames. Classes P2 and P1 correspond to an assured forwarding (AF) group of  
size 2. Finally, P0 is for best effort (BE) class.  
Features of the ZL50409 that correspond to the requirements of their associated IETF classes are summarized in  
the table below.  
Network management (NM) and Global buffer reservation for NM and EF  
Expedited forwarding (EF)  
Shaper for traffic on uplink port  
No dropping if admission controlled  
Assured forwarding (AF)  
Global buffer reservation for two AF classes  
Shaper for traffic on uplink port  
Random early discard, with programmable levels  
Best effort (BE)  
Service only when other queues are idle means that QoS not  
adversely affected  
Shaper for traffic on uplink port  
Random early discard, with programmable levels  
Traffic from flow control enabled ports automatically classified as BE  
Table 10 - ZL50409 Features Enabling IETF Diffserv Standards  
49  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
7.9 Failover Backplane Feature  
The ZL50409 implements a hardware assisted link failure detection mechanism utilizing a Link Heart Beat (LHB)  
packet. The LHB packet format is defined as a 64-byte MAC control frame with a user defined opcode. The packet  
format is illustrated below:  
01-80-C2-00-00-01  
xx-xx-xx-xx-xx-xx  
88-08  
yy-yy  
00-00-...  
CRC  
Where “xx-xx-xx-xx-xx-xx” is the source port MAC address and “yy-yy” is the special opcode defined by register  
setup (LHBReg0,1). The opcode “00-01” is reserved for the flow control packet. We recommend opcode “00-12” for  
the LHB packet.  
The LHB is done between two compatible MACs providing this function. A timer parameter will be set for both the  
receiver and transmitter (LHBTimer).  
On the transmission side, the MAC will monitor the transmission activities. If there is no activity for more than the  
set period, a LHB packet will be sent to its link partner. Therefore, there should always be at least one packet  
transmitted from the MAC for every period specified.  
On the receiving side, the MAC will also monitor the activity. If there is no good packet received for more than 2X  
the set period, an alarm will be raised to the CPU. The LHB packet is only used by the ZL50409 to reset the timeout  
counter, it is ignored otherwise (i.e. not passed on within the system).  
See the Failover Protection Application Note, ZLAN-43, for more information.  
8.0 Port Trunking  
See Port Trunking application note, ZLAN-48, for more information.  
8.1 Features and Restrictions  
A port group (i.e., trunk) can include up to 8 physical ports to form a fault tolerant link. There are eight trunk groups  
total.  
Load distribution among the ports in a trunk for unicast is performed using hashing based on source MAC address  
and destination MAC address. Three other options include source MAC address only, destination MAC address  
only, and source port (in bidirectional ring mode only). Load distribution for multicast is performed similarly.  
If a VLAN includes any of the ports in a trunk group, all the ports in that trunk group should be in the same VLAN  
member map.  
The ZL50409 also provides a safe fail-over mode for port trunking automatically. If one of the ports in the trunking  
group goes down, the ZL50409 can redistribute the traffic over to the remaining ports in the trunk with software  
assistance.  
8.2 Unicast Packet Forwarding  
The search engine finds the destination MCT entry, and if the status field says that the destination port found  
belongs to a trunk, then the trunk group number is retrieved.  
The source port of the packet is checked against the destination trunk group. If the source port belongs to the  
destination trunk group, the packet is discarded.  
A hash key, based on some combination of the source and destination MAC addresses for the current packet,  
selects the appropriate forwarding port, as specified in the Trunk_Hash registers. Each trunk has eight trunk_hash  
registers which selects one of the potential eight outgoing ports. The hash key provides a pseudo flow identifier  
which force the same flow to the same destination flow. As a result, the packet will always arrive in order.  
50  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
8.3 Multicast Packet Forwarding  
Multicast frame forwarding is only slightly more complex than unicast frame forwarding in a port trunking  
environment:  
1. Determine the VLAN to which the multicast frame belongs.  
2. Is the frame's source port a member of the VLAN? If so, exclude that port. Is the frame's source port a member  
of a trunk group? If so, exclude all other ports in that group as well.  
3. Finally, among the still-eligible members of the VLAN that belong to trunk groups, exclude all but one port from  
each trunk group. This selection is based on hashing or round robin, as in unicast frame forwarding.  
Example: Ports 0, 1, and 2 belong to trunk group A. Ports 3 and 4 belong to trunk group B. A multicast frame is  
received from source port 3. Suppose that the VLAN of the frame has member ports 0, 1, 2, 3, 4, 5, and 6.  
Ports 0, 1, 2, 3, 4, 5, and 6 are potential destination ports for the frame.  
Port 3 is excluded as a destination because it is the frame's source port.  
Port 4 is excluded as a destination because it belongs to the same trunk group as port 3.  
Two of the three ports in trunk group A must now be excluded. The ZL330ENG hashing algorithm is applied,  
and in this example, assume that ports 0 and 1 are excluded.  
Therefore, ports 2, 5 and 6 comprise the final set of destination ports for the multicast frame.  
9.0 Traffic Mirroring  
See Traffic Mirroring application note, ZLAN-50, for more information.  
9.1 Mirroring Features  
Packets can be mirrored (duplicated) for network monitor purpose and/or network debug purpose. Three types of  
mirroring is available in ZL50409.  
1. Source or Destination MAC address based  
2. Flow based  
3. Port based (RMII mode only)  
In source or destination mac address based mirroring, the “M” bit of the mirroring MAC address in the MCT is set.  
Also, the user need to specify the mirroring MAC address is source or destination of the packet. If source is  
selected, any packet received with the mirroring MAC address as source MAC address will be copied to the  
mirrored port. In the same way, if destination is selected, any packet received with mirroring MAC address as  
destination MAC address will be copied to the mirrored port.  
In flow based mirroring, a flow is established based on the source and destination mac address pair. When  
enabled, a packet with source and destination address match the pre-programmed source and destination mac  
address pair will be copied to the mirrored port. In reverse direction (source and destination match pre programmed  
destination and source), the flow can also be enabled and the frame will be copied to the mirrored port.  
In port based mirroring, traffic from any RMII port can be mirrored to any other RMII port. The traffic from the source  
port can be either ingress or egress traffic. Up to two ports can be setup as mirrored ports. As a result, the traffic  
(both ingress and egress) of a specific port can be monitored by setting up both mirrored ports. Once a port is setup  
as mirrored port, it cannot be used for regular traffic.  
The mirrored port can be any port in the ZL50409.  
9.2 Using port mirroring for loop back  
To perform remote loop back test, port mirroring can be used to bounce back the packet to the source port to check  
the data path.  
51  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
The CPU needs to setup the remote device through the command channel to enable port mirroring in the remote  
device. A CPU packet is send to the port in test in Device A. The packet will be forwarded to the test port, external  
cable, the destination port in Device B, and loop back to itself, back to the cable and go back to Device A and the  
CPU. This way, the whole channel can be tested.  
CPU  
DEVICE B  
DEVICE A  
Figure 13 - Remote Loopback Test  
10.0 Clocks  
10.1 Clock Requirements  
10.1.1 System Clock (SCLK) Speed Requirement  
SCLK is the primary clock for the ZL50409 device. The speed requirement is based on the system configuration.  
Below is a table for a few configuration.  
Minimum SCLK speed  
Configuration  
required  
6-9 ports 10/100 M  
1-5 ports 10/100 M  
50 MHz  
25 Mhz  
Table 11 - SCLK Speed Requirements  
10.1.2 RMAC Reference Clock (M_CLK) Speed Requirement  
M_CLK is a 50 MHz clock used for the RMAC ports (ports 0-7) and CPU port (port 8).  
If none of the RMAC ports are configured in RMII mode or Reverse MII mode, a different clock frequency can be  
applied to M_CLK, as long as it's less than 50 MHz. In this case, register USD must be set to provide an internal  
1usec timing.  
10.1.3 MMAC Reference Clock (REF_CLK) Speed Requirement  
REF_CLK is a reference clock required for the MMAC port (port 9).  
If the device is in a 9 port 10/100 configuration only, REF_CLK can be a lower frequency clock and can be  
connected to M_CLK to reduce the number of clock sources.  
If port 9 is not being used, REF_CLK can be left unconnected.  
10.1.4 JTAG Test Clock (TCK) Speed Requirements  
TCK is a clock used for the JTAG port. The frequency on this clock can vary. Refer to “JTAG (IEEE 1149.1-2001)”  
on page 139 for the frequency range.  
52  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
10.2 Clock Generation  
10.2.1 MDC  
MDC is used for the MII Management Interface and clocks data on MDIO. It is generated by the device from  
M_CLK and is equal to 500 kHz (M_CLK/100). If a different speed clock other than 50 MHz is used on M_CLK, the  
USD register must be programmed to reset MDC.  
10.2.2 SCL  
SCL is used for the I2C interface and clocks data on SDA. It is generated by the device from M_CLK and is equal to  
50kHz (M_CLK/1000). If a different speed clock other than 50 MHz is used on M_CLK, the USD register must be  
programmed to reset SCL.  
10.2.3 Ethernet Interface Clocks  
If the RMAC ports are configured in Reverse MII mode, TXCLK and RXCLK are generated from M_CLK and are  
equal to M_CLK/2 for 100 M mode or M_CLK/20 for 10M mode. M_CLK needs to be a 50 MHz clock in this mode.  
If the RMAC ports are configured in Reverse GPSI mode, TXCLK and RXCLK are generated from M_CLK and are  
equal to M_CLK/2 for 10 M mode. M_CLK needs to be a 20 MHz clock in this mode and USD must be programmed  
accordingly.  
For the CPU port in serial+MII mode, TXCLK and RXCLK are generated from M_CLK and are equal to M_CLK/2 for  
100 M mode or M_CLK/20 for 10 M mode. M_CLK needs to be a 50 MHz clock in this mode.  
If the MMAC port is configured in Reverse MII mode, RXCLK is generated from REF_CLK and is equal to  
REF_CLK/2 for 100 M mode (no support for 10M Reverse MII mode). REF_CLK needs to be a 50 MHz clock in this  
mode.  
11.0 Hardware Statistics Counters  
11.1 Hardware Statistics Counters List  
ZL50409 hardware provides a full set of statistics counters for each Ethernet port. The CPU accesses these  
counters through the CPU interface. All hardware counters are rollover counters. When a counter rolls over, the  
CPU is interrupted, so that long-term statistics may be kept. The MAC detects all statistics, except for the filtering  
counter (detected by queue manager). The following is the wrapped signal sent to the CPU through the command  
block.  
See Processor Interface application note, ZLAN-26, for more information.  
11.2 IEEE 802.3 HUB Management (RFC 1516)  
11.2.1 Event Counters  
11.2.1.1 PortReadableFrames  
Counts the number of frames of valid frame length that have been received on this port.  
53  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Min. Frame Size  
> 64 bytes,  
Max. Frame Size  
< 1518 bytes  
Frame size:  
(< 1522 bytes, if  
VLAN tagged)  
No FCS (i.e. checksum) error  
No collisions  
Use ZL50409 counter “Total Frames Received”, C[8].  
Note: max. frame size may be BUF_LIMIT, if enabled on this port.  
11.2.1.2 PortReadableOctets  
Counts the number of bytes (i.e. octets) contained in valid frames that have been received on this port.  
Min. Frame Size  
> 64 bytes,  
Max. Frame Size  
< 1518 bytes  
Frame size:  
(< 1522 bytes, if  
VLAN tagged)  
No FCS error  
No collisions  
Use ZL50409 counter “Total Bytes Received”, C[7].  
Note: max. frame size may be BUF_LIMIT, if enabled on this port.  
11.2.1.3 PortFCSErrors  
Counts number of valid frames received with bad FCS.  
Min. Frame Size  
> 64 bytes,  
Max. Frame Size  
< 1518 bytes  
Frame size:  
(< 1522 bytes, if  
VLAN tagged)  
No framing error  
No collisions  
Use ZL50409 counter “CRC”, C[23].  
Note: if BUF_LIMIT is enabled on this port, this counter still uses the above max. frame size definition. If a frame  
>1518B but <BUF_LIMIT has a CRC error, it will be countered as an Oversized frame.  
54  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
11.2.1.4 PortAlignmentErrors  
Counts number of valid frames received with bad alignment (not byte-aligned).  
Min. Frame Size  
Max. Frame Size  
< 1518 bytes  
Frame size:  
> 64 bytes,  
(< 1522 bytes, if  
VLAN tagged)  
Framing error  
FCS error  
No collisions  
Use ZL50409 counter “Alignment Error”, C[21].  
Note: when this counter is incremented, the ZL50409 also increments the “CRC” counter, C[23].  
11.2.1.5 PortFrameTooLongs  
Counts number of frames received with size exceeding the maximum allowable frame size.  
Min. Frame Size  
n/a  
Max. Frame Size  
> 1518 bytes  
Frame size:  
(> 1522 bytes, if  
VLAN tagged)  
Framing error: don’t care  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Oversize Frames”, C[15].  
Note: max. frame size may be BUF_LIMIT, if enabled on this port. Also, if a frame >1518B but <BUF_LIMIT has a  
CRC error, it will be countered as an Oversized frame.  
11.2.1.6 PortShortEvents  
Counts number of frames received with size less than the length of a short event.  
Min. Frame Size  
< 10 bytes  
Max. Frame Size  
Frame size:  
Framing error: don’t care  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Short Event”, C[24].  
55  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
11.2.1.7 PortRunts  
Counts number of frames received with size under 64 bytes, but greater than the length of a short event.  
Min. Frame Size  
> 10 bytes,  
Max. Frame Size  
< 64 bytes  
Frame size:  
Framing error: don’t care  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Undersize Frames”, C[22].  
11.2.1.8 PortCollisions  
Counts number of collision events.  
Min. Frame Size  
Max. Frame Size  
Frame size:  
any size  
Use ZL50409 counter “Collision”, C[25].  
11.2.1.9 PortLateEvents  
Counts number of collision events that occurred late (after LateEventThreshold = 64 bytes).  
Min. Frame Size  
Max. Frame Size  
Frame size:  
any size  
Use ZL50409 counter “Port Late Collision”, C[29].  
Note: when this counter is incremented, the ZL50409 also increments the “Collision” counter, C[25].  
11.2.1.10 PortVeryLongEvents  
Counts number of frames received with size larger than Jabber Lockup Protection Timer (TW3 = 5 ms or 50 000 bit  
times – 20% + 50%).  
Min. Frame Size  
> TW3  
Max. Frame Size  
Frame size:  
No ZL50409 counter.  
Note: the ZL50409 defines a jabber frame as any frame that exceeds 6400 bytes, however, the maximum buffer  
size supported by the device is 4 KBytes. Thus, any frame > 4KB would be counted as an Oversized Frame, C[15].  
56  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
11.2.1.11 PortDataRateMisatches  
For repeaters or HUB application only. No ZL50409 counter.  
11.2.1.12 PortAutoPartitions  
For repeaters or HUB application only. No ZL50409 counter.  
11.2.1.13 PortTotalErrors  
Sum of the following errors:  
PortFCSErrors  
PortAlignmentErrors  
PortFrameTooLong  
PortShortEvents  
PortLateEvents  
PortVeryLongEvents  
PortDataRateMisatches  
11.3 IEEE 802.1 Bridge Management (RFC 1286)  
11.3.1 Event Counters  
11.3.1.1 PortDelayExceededDiscards  
Counts number of frames discarded due to excessive transmit delay through the bridge.  
Note: Not applicable for the ZL50409.  
11.3.1.2 PortMtuExceededDiscards  
Counts number of frames discarded due to excessive size.  
11.3.1.3 PortInFrames  
Counts number of frames received by this port or segment.  
Note: A frame received by this port is only counted by this counter if and only if it is for a protocol being processed  
by the local bridge function.  
11.3.1.4 PortOutFrames  
Counts number of frames transmitted by this port.  
Note: A frame transmitted by this port is only counted by this counter if and only if it is for a protocol being  
processed by the local bridge function.  
11.3.1.5 PortInDiscards  
Counts number of valid frames received which were discarded (i.e. filtered) by the forwarding process.  
57  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
11.4 RMON – Ethernet Statistic Group (RFC 1757)  
11.4.1 Event Counters  
11.4.1.1 DropEvents  
Counts number of times a packet is dropped, because of lack of available resources. DOES NOT include all packet  
dropping -- for example, random early drop for quality of service support.  
Use ZL50409 counter “Drop”, C[26].  
11.4.1.2 Octets  
Counts the total number of octets (i.e. bytes) in any frames received.  
Min. Frame Size  
> 64 bytes,  
Max. Frame Size  
< 1518 bytes  
Frame size:  
(< 1522 bytes, if  
VLAN tagged)  
No framing error  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Bytes Received”, C[5].  
Note: max. frame size may be BUF_LIMIT, if enabled on this port.  
11.4.1.3 Pkts  
Counts the number of frames received, good or bad.  
Min. Frame Size  
> 64 bytes,  
Max. Frame Size  
< 1518 bytes  
Frame size:  
(< 1522 bytes, if  
VLAN tagged)  
No framing error  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Frames Received”, C[6].  
Note: max. frame size may be BUF_LIMIT, if enabled on this port.  
11.4.1.4 BroadcastPkts  
Counts the number of good frames received and forwarded with broadcast address. Does not include  
non-broadcast multicast frames.  
Use ZL50409 counter “Broadcast Frames Received”, C[11].  
58  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
11.4.1.5 MulticastPkts  
Counts the number of good frames received and forwarded with multicast address. Does not include broadcast  
frames.  
Use ZL50409 counter “Multicast Frames Received”, C[10].  
Note: this counter includes broadcast frames received.  
11.4.1.6 CRCAlignErrors  
Counts number of frames received with FCS or alignment errors.  
Min. Frame Size  
> 64 bytes,  
Max. Frame Size  
< 1518 bytes  
Frame size:  
(< 1522 bytes, if  
VLAN tagged)  
Framing error and/or FCS error  
No collisions  
Use ZL50409 counters “CRC”, C[23], and “Alignment Error”, C[21].  
Note: when the “Alignment Error” counter, C[21], is incremented, the ZL50409 also increments the “CRC” counter,  
C[23], thus, the CRC counter can be used for this statistic.  
11.4.1.7 UndersizePkts  
Counts number of frames received with size less than 64 bytes.  
Min. Frame Size  
n/a  
Max. Frame Size  
< 64 bytes  
Frame size:  
Framing error: don’t care  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Undersize Frames”, C[22].  
11.4.1.8 OversizePkts  
Counts number of frames received with size exceeding the maximum allowable frame size.  
59  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Min. Frame Size  
n/a  
Max. Frame Size  
> 1518 bytes  
Frame size:  
(> 1522 bytes, if  
VLAN tagged)  
Framing error: don’t care  
FCS error: don’t care  
No collisions  
Use ZL50409 counter “Oversize Frames”, C[15].  
Note: max. frame size may be BUF_LIMIT, if enabled on this port.  
11.4.1.9 Fragments  
Counts number of frames received with size less than 64 bytes and with bad FCS.  
Min. Frame Size  
n/a  
Max. Frame Size  
< 64 bytes  
Frame size:  
Framing error and/or FCS error  
No collisions  
Use ZL50409 counter “Fragments”, C[20].  
11.4.1.10 Jabbers  
Counts number of frames received with size exceeding maximum frame size and with bad FCS.  
Note that this definition of jabber is different than the definition in IEEE 802.3 (this standard defines jabber as the  
condition where any packet exceeds Jabber Lockup Protection Timer (TW3)).  
Min. Frame Size  
n/a  
Max. Frame Size  
> 1518 bytes  
Frame size:  
(> 1522 bytes, if  
VLAN tagged)  
Framing error: don’t care  
FCS error  
No collisions  
No ZL50409 counter.  
Note: the ZL50409 defines a jabber frame as any frame that exceeds 6400 bytes, however, the maximum buffer  
size supported by the device is 4 KBytes. Thus, any frame > 4 KB would be counted as an Oversized Frame, C[15].  
60  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
11.4.1.11 Collisions  
Counts number of collision events detected.  
Only a best estimate since collisions can only be detected while in transmit mode, but not while in receive mode.  
Min. Frame Size  
Max. Frame Size  
Frame size:  
any size  
Use ZL50409 counter “Collision”, C[25].  
11.4.1.12 Packet Count for Different Size Groups  
Six different size groups – one counter for each. Counts both good and bad packets.  
Pkts64Octets  
for any packet with size = 64 bytes.  
Use ZL50409 counter “Frames with Length of 64 Bytes”, C[12].  
for any packet with size from 65 bytes to 127 bytes  
Pkts65to127Octets  
Pkts128to255Octets  
Pkts256to511Octets  
Pkts512to1023Octets  
Pkts1024to1518Octets  
Use ZL50409 counter “Frames with Length Between 65-127 Bytes”, C[14].  
or any packet with size from 128 bytes to 255 bytes  
Use ZL50409 counter “Frames with Length Between 128-255 Bytes”, C[16].  
for any packet with size from 256 bytes to 511 bytes  
Use ZL50409 counter “Frames with Length Between 256-511 Bytes”, C[17].  
for any packet with size from 512 bytes to 1023 bytes  
Use ZL50409 counter “Frames with Length Between 512-1023 Bytes”, C[18].  
for any packet with size from 1024 bytes to 1518 bytes  
Use ZL50409 counter “Frames with Length Between 1024-1518 Bytes”, C[19].  
Note: the ZL50409 will include frames up to max. frame size.  
Note: the ZL50409 doesn’t include bad frames in the above counters.  
11.5 Miscellaneous Counters  
In addition to the statistics groups defined in previous sections, the ZL50409 has other statistics counters for its own  
purposes.  
1. Flow control – one counting the number of flow control frames received, C[9], and another counting the number  
of flow control frames sent, C[3].  
2. Frames sent – one for unicast frames sent, C[1], and one for non-unicast frames sent, C[4]. A broadcast or mul-  
ticast frame qualifies as non-unicast.  
3. A counter called “frame send fail”, C[2]. This keeps track of FIFO under-runs, late collisions, and collisions that  
have occurred 16 times.  
4. A counter called “filtering”, C[27]. This keeps track of all frames dropped due to queue congestion (i.e. egress  
WRED).  
61  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.0 Register Definition  
12.1 ZL50409 Register Description  
I²C  
Addr  
(Hex)  
CPU Addr  
(Hex)  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
0. ETHERNET Port Control Registers (Substitute [n] with Port number (0..9))  
ECR1Pn  
ECR2Pn  
ECR3Pn  
ECR4Pn  
Port Control Register 1 for  
Port n  
Port Control Register 2 for  
Port n  
Port Control Register 3 for  
Port n  
Port Control Register 4 for  
Port n  
0000+2n  
0001+2n  
0080+2n  
0081+2n  
R/W  
R/W  
R/W  
R/W  
000+n  
00A+n  
014+n  
01E+n  
C0  
00  
00  
18  
BUF_LIMIT  
FCC  
Frame Buffer Limit  
Flow Control Grant Period  
0036  
0037  
R/W  
R/W  
NA  
NA  
40  
03  
1. VLAN Control Registers (Substitute [n] with Port number (0..9))  
AVTCL  
VLAN Type Code Register  
Low  
VLAN Type Code Register  
High  
Port n Configuration  
Register 0  
Port n Configuration  
Register 1  
0100  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
028  
029  
00  
81  
FF  
FF  
00  
00  
AVTCH  
0101  
PVMAPn_0  
PVMAPn_1  
PVMAPn_3  
PVMODE  
0102+4n  
0103+4n  
0105+4n  
0170  
02A+n  
034+n  
03E+n  
048  
Port n Configuration  
Register 3  
VLAN Operating Mode  
2. TRUNK Control Registers (Substitute [n] with Trunk Group number (0..7))  
TRUNKn  
TRUNKn_HASH10  
Trunk Group n  
Trunk Group n Hash 10  
Destination Port  
0200+n  
0208+4n  
R/W  
R/W  
NA  
NA  
00  
00  
TRUNKn_HASH32  
TRUNKn_HASH54  
TRUNKn_HASH76  
MULTICAST_HASHn-0  
Trunk Group n Hash 32  
Destination Port  
Trunk Group n Hash 54  
Destination Port  
Trunk Group n Hash 76  
Destination Port  
Multicast hash result n  
mask byte 0  
0209+4n  
020A+4n  
020B+4n  
0228+2n  
R/W  
R/W  
R/W  
R/W  
NA  
NA  
NA  
NA  
00  
00  
00  
FF  
Table 12 - Register Description  
62  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
MULTICAST_HASHn-1  
Multicast hash result n  
mask byte 1  
0229+2n  
R/W  
NA  
FF  
3. CPU Port Configuration  
MAC0  
MAC1  
MAC2  
MAC3  
MAC4  
MAC5  
INT_MASK0  
INTP_MASKn  
CPU MAC Address byte 0  
CPU MAC Address byte 1  
CPU MAC Address byte 2  
CPU MAC Address byte 3  
CPU MAC Address byte 4  
CPU MAC Address byte 5  
Interrupt Mask 0  
0300  
0301  
0302  
0303  
0304  
0305  
0306  
0310+n  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
00  
00  
00  
00  
00  
00  
00  
00  
Interrupt Mask for MAC  
Port 2n, 2n+1  
(n=0..4)  
RQS  
RQSS  
MAC01  
Receive Queue Select  
Receive Queue Status  
Increment MAC port 0,1  
address  
0323  
0324  
0325  
R/W  
RO  
R/W  
NA  
NA  
NA  
00  
NA  
00  
MAC23  
MAC45  
MAC67  
Increment MAC port 2,3  
address  
Increment MAC port 4,5  
address  
Increment MAC port 6,7  
address  
0326  
0327  
0328  
R/W  
R/W  
R/W  
NA  
NA  
NA  
00  
00  
00  
MAC9  
Port 9 MAC address byte 5  
0329  
0330-0336  
0337  
0338-0339  
033A-033E  
033F  
R/W  
R/W  
RO  
RO  
R/W  
R/W  
NA  
NA  
NA  
NA  
NA  
NA  
00  
00  
NA  
NA  
00  
CPUQINS[6:0]  
CPUQINSRPT  
CPUGRNHDL[1:0]  
CPURLSINFO[4:0]  
CPUGRNCTR  
00  
4. Search Engine Configurations  
AGETIME_LOW  
AGETIME_HIGH  
SE_OPMODE  
MAC Address Aging Time  
0400  
0401  
0403  
R/W  
R/W  
R/W  
049  
04A  
NA  
5C  
00  
00  
Low  
MAC Address Aging Time  
High  
Search Engine Operating  
Mode  
5. Global QOS Control  
QOSC  
QOS Control  
0500  
R/W  
04B  
00  
Table 12 - Register Description (continued)  
63  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
PCC  
MCC  
Packet Congestion Control  
Multicast Congestion  
Control  
0510  
0511  
R/W  
R/W  
068  
069  
006  
06  
MCCTH  
Multicast Congestion  
Threshold  
0512  
R/W  
NA  
03  
RDRC0  
RDRC1  
RDRC2  
SFCB  
C1RS  
C2RS  
WRED Drop Rate Control 0  
WRED Drop Rate Control 1  
WRED Drop Rate Control 2  
Share FCB Size  
Class 1 Reserve Size  
Class 2 Reserve Size  
Class 3 Reserve Size  
VLAN Priority Map Low  
VLAN Priority Map Middle  
VLAN Priority Map High  
VLAN Discard Map  
TOS Priority Map Low  
TOS Priority Map Middle  
TOS Priority Map High  
TOS Discard Map  
User Define Protocol n  
User Define Protocol 0 To 7  
Force Discard Enable  
0513  
0514  
0515  
0518  
0519  
051A  
051B  
0530  
0531  
0532  
0533  
0540  
0541  
0542  
0543  
0550+n  
0558  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
090  
091  
NA  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
074  
075  
076  
077  
056  
057  
058  
05C  
059  
05A  
05B  
05D  
0B3+n  
0BB  
C3RS  
AVPML  
AVPMM  
AVPMH  
AVDM  
TOSPML  
TOSPMM  
TOSPMH  
TOSDML  
USER_PROTOCOL_n  
USER_PROTOCOL_  
FORCE_DISCARD  
(n=0..7)  
WLPP10  
WLPP32  
WLPP54  
WLPP76  
WLPE  
Well Known Logic Port 0  
and 1 Priority  
Well Known Logic Port 2  
and 3 Priority  
Well Known Logic Port 4  
and 5 Priority  
Well Known Logic Port 6  
and 7 Priority  
Well Known Logic Port 0 To  
7 Enable  
Well Known Logic Port 0 To  
7 Force Discard Enable  
0560  
0561  
0562  
0563  
0564  
0565  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
0A8  
0A9  
0AA  
0AB  
0AC  
0AD  
00  
00  
00  
00  
00  
00  
WLPFD  
Table 12 - Register Description (continued)  
64  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
USER_PORTn_LOW  
USER_PORTn_HIGH  
User Define Logical Port n  
Low  
User Define Logical Port n  
High  
User Define Logic Port 0  
and 1 Priority  
User Define Logic Port 2  
and 3 Priority  
User Define Logic Port 4  
and 5 Priority  
User Define Logic Port 6  
and 7 Priority  
User Define Logic Port 0 To  
7 Enable  
User Define Logic Port 0 To  
7 Force Discard Enable  
User Define Range Low Bit  
[7:0]  
User Define Range Low Bit  
[15:8]  
User Define Range High  
Bit [7:0]  
User Define Range High  
Bit [15:8]  
0570+2n  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
092+n  
09A+n  
0A2  
00  
(n=0..7)  
0571+2n  
0590  
0591  
0592  
0593  
0594  
0595  
05A0  
05A1  
05A2  
05A3  
05A4  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
USER_PORT1:0_  
PRIORITY  
USER_PORT3:2_  
PRIORITY  
USER_PORT5:4_  
PRIORITY  
USER_PORT7:6_  
PRI ORITY  
0A3  
0A4  
0A5  
USER_PORT_  
ENABLE[7:0]  
0A6  
USER_PORT_  
0A7  
FORCE_DISCARD[7:0]  
RLOWL  
0AE  
0AF  
0B0  
RLOWH  
RHIGHL  
RHIGHH  
RPRIORITY  
0B1  
User Define Range Priority  
0B2  
6. MISC Configuration Register  
MII_OP0  
MII_OP1  
FEN  
MIIC0  
MIIC1  
MIIC2  
MIIC3  
MIID0  
MIID1  
USD  
MII Register Option 0  
MII Register Option 1  
Feature Registers  
MII Command Register 0  
MII Command Register 1  
MII Command Register 2  
MII Command Register 3  
MII Data Register 0  
0600  
0601  
0602  
0603  
0604  
0605  
0606  
0607  
0608  
0609  
060A  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
RO  
0BC  
0BD  
0BE  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
00  
00  
10  
00  
00  
00  
00  
NA  
NA  
00  
02  
MII Data Register 1  
One micro second divider  
Device id and test  
RO  
R/W  
R/W  
DEVICE  
NA  
Table 12 - Register Description (continued)  
65  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
SUM  
EEPROM Checksum  
Register  
Link heart beat time out  
timer  
060B  
R/W  
R/W  
0FF  
00  
LHBTimer  
0610  
NA  
00  
LHBReg0  
LHBReg1  
LHB control field value[7:0]  
LHB control field value  
[15:8]  
0611  
0612  
R/W  
R/W  
NA  
NA  
00  
00  
fMACCReg0  
Forced MAC control field  
value [7:0]  
Forced MAC control field  
value [15:8]  
FCB Base Address  
Register 0  
FCB Base Address  
Register 1  
0613  
0614  
0620  
0621  
0622  
R/W  
R/W  
R/W  
R/W  
R/W  
NA  
NA  
00  
00  
00  
60  
00  
fMACCReg1  
FCB_BASE_ADDR0  
FCB_BASE_ADDR1  
FCB_BASE_ADDR2  
0BF  
0C0  
0C1  
FCB Base Address  
Register 2  
7. Port Mirroring Controls  
MIRROR_DEST_MAC0  
Mirror Destination MAC  
Address 0  
Mirror Destination MAC  
Address 1  
Mirror Destination MAC  
Address 2  
Mirror Destination MAC  
Address 3  
Mirror Destination MAC  
Address 4  
Mirror Destination MAC  
Address 5  
Mirror Source MAC  
Address 0  
Mirror Source MAC  
Address 1  
0700  
0701  
0702  
0703  
0704  
0705  
0706  
0707  
0708  
0709  
070A  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
00  
MIRROR_DEST_MAC1  
MIRROR_DEST_MAC2  
MIRROR_DEST_MAC3  
MIRROR_DEST_MAC4  
MIRROR_DEST_MAC5  
MIRROR_SRC_MAC0  
MIRROR_SRC_MAC1  
MIRROR_SRC_MAC2  
MIRROR_SRC_MAC3  
MIRROR_SRC_MAC4  
Mirror Source MAC  
Address 2  
Mirror Source MAC  
Address 3  
Mirror Source MAC  
Address 4  
Table 12 - Register Description (continued)  
66  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
MIRROR_SRC_MAC5  
Mirror Source MAC  
Address 5  
070B  
R/W  
NA  
00  
MIRROR_CONTROL  
RMII_MIRROR0  
RMII_MIRROR1  
8. Per Port QOS Control  
FCRn  
Port Mirror Control Register  
RMII Mirror 0  
RMII Mirror 1  
070C  
0710  
0711  
R/W  
R/W  
R/W  
NA  
NA  
NA  
00  
00  
00  
Flooding Control Register n  
Broadcast/Multicast Rate  
Control n  
0800+n  
0820+n  
R/W  
R/W  
04C+n  
05E+n  
00  
00  
(n=0..9)  
BMRCn  
PR100_n  
Port Reservation for RMAC  
Ports (n=0..7)  
0840+n  
R/W  
06A+n  
06  
‘d1536/1  
6=‘d96,  
‘d96>>4=  
’h6  
PR100_CPU  
PRM  
Port Reservation for CPU  
Port  
Port Reservation for MMAC  
Port  
0848  
0849  
R/W  
R/W  
073  
072  
06  
24  
‘d96  
‘d96x6=‘d  
576,  
‘d576>>4  
=’h24  
PTH100_n  
PTH100_CPU  
PTHM  
Port Threshold for RMAC  
Ports (n=0..7)  
Port Threshold for CPU  
Port  
Port Threshold for MMAC  
Port  
QOS Control n  
0860+n  
0868  
R/W  
R/W  
R/W  
0C2+n  
0CB  
03  
03  
12  
00  
½
½
½
0869  
0CA  
QOSCn  
0880+n  
R/W 078-08F  
NA  
(n=0..39)  
E. System Diagnostic  
DTSRL  
DTSRM  
TESTOUT0  
TESTOUT1  
MASK0  
MASK1  
MASK2  
MASK3  
MASK4  
Test Register Low  
Test Register Medium  
Testmux Output [7:0]  
Testmux Output [15:8]  
MASK Timeout 0  
MASK Timeout 1  
MASK Timeout 2  
MASK Timeout 3  
MASK Timeout 4  
0E00  
0E01  
0E02  
0E03  
0E10  
0E11  
0E12  
0E13  
0E14  
R/W  
R/W  
R/O  
R/O  
R/W  
R/W  
R/W  
R/W  
R/W  
NA  
NA  
NA  
00  
01  
NA  
NA  
00  
00  
00  
00  
00  
NA  
0F6  
0F7  
0F8  
0F9  
0FA  
Table 12 - Register Description (continued)  
67  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
BOOTSTRAP[2:0]  
PRTFSMSTn  
BOOTSTRAP Read Back  
Ethernet Port n Status  
Read Back  
RMAC Port n QOS and  
Queue Status  
CPU Port QOS and Queue  
Status A  
CPU Port QOS and Queue  
Status B  
MMAC Port QOS and  
Queue Status A  
MMAC Port QOS and  
Queue Status B  
0E80-0E82  
0E90+n  
RO  
RO  
NA  
NA  
NA  
NA  
(n=0..9)  
(n=0..7)  
PRTQOSSTn  
PRTQOSST8A  
PRTQOSST8B  
PRTQOSST9A  
PRTQUSST9B  
0EA0+n  
0EA8  
RO  
RO  
RO  
RO  
RO  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
0EA9  
0EAA  
0EAB  
CLASSQOSST  
PRTINTCTR  
QMCTRLn  
QCTRL  
BMBISTR0  
BMBISTR1  
BMControl  
BUFF_RST  
FCBHEADPTR0  
FCB_HEAD_PTR1  
FCB_TAIL_PTR0  
FCB_TAIL_PTR1  
FCB_NUM0  
FCB_NUM1  
Class Buffer Status  
Buffer Interrupt Status  
Ports Queue Control Status  
Ports Queue Control  
Memory bist result  
Memory bist result  
Memory control  
Buffer Reset Pool  
FCB Head Pointer [7:0]  
FCB Head Pointer [15:8]  
FCB Tail Pointer [7:0]  
FCB Tail Pointer [15:8]  
FCB Number [7:0]  
0EAC  
0EAD  
0EB0+n  
0EBA  
0EBB  
0EBC  
0EBD  
0EC0  
0EC1  
0EC2  
0EC3  
0EC4  
0EC5  
0EC6  
RO  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
00  
00  
00  
NA  
NA  
0F  
00  
00  
00  
00  
00  
00  
06  
R/W  
R/W  
R/W  
R/O  
R/O  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
(n=0..9)  
FCB Init Start and FCB  
Number [14:8]  
BM_RLSFF_CTRL  
BM_RLSFF_INFO0  
BM_RLSFF_INFO1  
BM_RLSFF_INFO2  
BM_RLSFF_INFO3  
BM_RLSFF_INFO4  
BM_RLSFF_INFO5  
Read control register  
Bm_rlsfifo_info[7:0]  
Bm_rlsfifo_info[15:8]  
Bm_rlsfifo_info[23:16]  
Bm_rlsfifo_info[31:24]  
Bm_rlsfifo_info[39:32]  
0EC7  
0EC8  
0EC9  
0ECA  
0ECB  
0ECC  
0ECD  
R/W  
RO  
RO  
RO  
RO  
RO  
RO  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
00  
NA  
NA  
NA  
NA  
NA  
NA  
Fifo_cnt[2:0],Bm_rlsfifo_inf  
o[44:40]  
Table 12 - Register Description (continued)  
68  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
I²C  
Addr  
(Hex)  
CPU Addr  
Default  
(Hex)  
Register  
Description  
R/W  
Notes  
(Hex)  
F. System Control  
GCR  
DCR  
DCR1  
DPST  
DTST  
DA  
Global Control Register  
Device Control Register  
Device Control Register 1  
Device Port Status Register  
Data read back register  
DA Register  
0F00  
0F01  
0F02  
0F03  
0F04  
0FFF  
R/W  
RO  
RO  
R/W  
RO  
RO  
NA  
NA  
NA  
NA  
NA  
NA  
00  
NA  
NA  
00  
NA  
DA  
Table 12 - Register Description (continued)  
12.2 Directly Accessed Registers  
INDEX_REG0  
Width  
Access  
Address  
Used to write the address of the indirect register to be accessed.  
8/16-bit  
W
0
Default: 00  
Bit #  
16-bit or serial CPU Interface  
[15:0] INDEX  
8-bit CPU Interface  
[7:0] INDEX_L  
Name  
Type  
W
Description  
16-bit address of the indirect register  
W
LSB [7:0] of the 16-bit address of the indirect register  
Register Table 1 - 0, INDEX_REG0  
INDEX_REG1  
Width  
Access  
Address  
Used to write the address of the indirect register to be accessed.  
8-bit  
W
1
Default: 00  
8-bit CPU Interface Only  
Bit #  
Name  
Type  
Description  
MSB [15:8] of the 16-bit address of the indirect register  
[7:0]  
INDEX_H  
W
Register Table 2 - 1, INDEX_REG1  
69  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
DATA_REG  
Width  
Access  
Address  
Reflects the value of the indirect access register set by INDEX_REG  
8-bit  
R/W  
2
Default: 00  
Bit #  
Name  
Type  
Description  
[7:0]  
DATA  
R/W  
8-bit indirect register data  
Register Table 3 - 2, DATA_REG  
CPU_FRAME_REG  
Width  
Access  
Address  
Used to transmit/receive Ethernet frames via an 8-byte FIFO to/from  
the CPU MAC.  
8/16-bit  
R/W  
3
Default: 00  
This register (FIFO) is disabled in SSI+MII CPU interface mode.  
Bit #  
16-bit or serial CPU Interface  
[15:0] CPU_FRAME  
Name  
Type  
Description  
W
Send Ethernet frame to CPU MAC. Bits [7:0] is even byte, [15:8] is  
odd byte.  
Data sequence specified in Processor Interface application note,  
ZLAN-26.  
R
Receive Ethernet frame from CPU MAC. Bits [7:0] is even byte,  
[15:8] is odd byte.  
Data sequence specified in Processor Interface application note,  
ZLAN-26.  
8-bit CPU Interface  
[7:0] CPU_FRAME  
W
R
Send Ethernet frame to CPU MAC  
Data sequence specified in Processor Interface application note,  
ZLAN-26.  
Receive Ethernet frame from CPU MAC  
Data sequence specified in Processor Interface application note,  
ZLAN-26.  
Register Table 4 - 3, CPU_FRAME_REG  
70  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
CMD_STATUS_REG  
Width  
Access  
Address  
CPU interface command status  
8-bit  
R/W  
4
Default: 00  
This register is not applicable in SSI+MII, MII-only and Remote/No  
CPU interface modes.  
Bit #  
Name  
Type  
Description  
[0]  
RXBUF_DONE  
W
Set Control Frame Receive buffer ready, after CPU writes a  
complete frame into the buffer. This bit is self-cleared.  
RXBUF_RDY  
R
Control Frame receive buffer ready, CPU can write a new frame  
1 – CPU can write a new control command  
0 – CPU has to wait until this bit is 1 to write a new control  
command  
[1]  
[2]  
[3]  
TXBUF1_DONE  
TXBUF1_RDY  
W
R
Set Control Frame Transmit buffer1 ready, after CPU reads out a  
complete frame from the buffer. This bit is self-cleared.  
Control Frame transmit buffer1 ready for CPU to read  
1 – CPU can read a new control command 1  
0 – CPU has to wait until this bit is 1 to read a new control  
command  
TXBUF2_DONE  
TXBUF2_RDY  
W
R
Set Control Frame Transmit buffer2 ready, after CPU reads out a  
complete frame from the buffer. This bit is self-cleared.  
Control Frame transmit buffer2 ready for CPU to read  
1 – CPU can read a new control command 1  
0 – CPU has to wait until this bit is 1 to read a new control  
command  
TXFIFO_RXDONE  
W
Set this bit to indicate CPU received a whole frame (transmit FIFO  
frame receive done), and flushed the rest of frame fragment, If  
occurs. This bit will be self-cleared.  
TXFIFO_RDY  
RXFIFO_EOF  
R
Transmit FIFO has data for CPU to read  
[4]  
[5]  
W
Set this bit to indicate that the following Write to the Receive FIFO  
is the last one. This bit will be self-cleared.  
RXFIFO_SPOK  
R
Receive FIFO has space for incoming CPU frame  
RXFIFO_REALIGN  
W
Set this bit to re-start the data that is sent from the CPU to Receive  
FIFO (re-align). This feature can be used for software debug. For  
normal operation must be '0'.  
TXFIFO_EOF  
RSVD  
R
Transmit FIFO End Of Frame  
Reserved  
[7:6]  
R/W  
Register Table 5 - 4, CMD_STATUS_REG  
71  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
INT_REG  
Width  
Access  
Address  
Interrupt sources  
8-bit  
R
5
Default: N/A  
Bit #  
Name  
Type  
Description  
[0]  
INT_CPU_FRAME  
R
Ethernet frame interrupt. Ethernet Frame receive buffer has data  
for processor to read  
[1]  
[2]  
INT_CTL_BUF1  
INT_CTL_BUF2  
R
R
Control frame 1 interrupt. Control Frame receive buffer 1 has data  
for processor to read  
Control frame 2 interrupt. Control Frame receive buffer 2 has data  
for processor to read  
[6:3]  
[7]  
RSVD  
R
R
Reserved  
INT_CHIP_RESET  
Device Timeout Detected interrupt  
Note: This bit is not self-cleared. After reading, the CPU has to  
clear the bit writing 0 to it.  
Register Table 6 - 5, INT_REG  
CTL_FRAME_BUF1  
Width  
Access  
Address  
Used to transmit/receive control frames  
8/16-bit  
R/W  
6
Default: 00  
Bit #  
16-bit or serial CPU Interface  
[15:0] CTL_BUF1  
Name  
Type  
Description  
W
Send control frame to command engine. Bits [7:0] is even byte,  
[15:8] is odd byte.  
Control frame format specified in Processor Interface application  
note, ZLAN-26.  
R
Receive control frame from command engine. Bits [7:0] is even  
byte, [15:8] is odd byte.  
Control frame format specified in Processor Interface application  
note, ZLAN-26.  
Register Table 7 - 6, CTL_FRAME_BUF1  
72  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
8-bit CPU Interface  
[7:0] CTL_BUF2  
W
R
Send control frame to command engine  
Control frame format specified in Processor Interface application  
note, ZLAN-26.  
Receive control frame from command engine  
Control frame format specified in Processor Interface application  
note, ZLAN-26.  
Register Table 7 - 6, CTL_FRAME_BUF1 (continued)  
CTL_FRAME_BUF2  
Width  
Access  
Address  
Used to receive control frames  
8/16-bit  
R
7
Default: 00  
Bit #  
16-bit or serial CPU Interface  
[15:0] CTL_BUF2  
Name  
Type  
Description  
R
Receive control frame from command engine. Bits [7:0] is even  
byte, [15:8] is odd byte.  
Control frame format specified in Processor Interface application  
note, ZLAN-26.  
8-bit CPU Interface  
[7:0] CTL_BUF2  
R
Receive control frame from command engine  
Control frame format specified in Processor Interface application  
note, ZLAN-26.  
Register Table 8 - 7, CTL_FRAME_BUF2  
12.3 Indirectly Accessed Registers  
12.3.1 (Group 0 Address) MAC Ports Group  
12.3.1.1 ECR1Pn: Port n Control Register  
I²C Address: h000+n; CPU Address: h0000+2n (n = port number)  
Accessed by CPU and I²C (R/W)  
Port 0 – 7 & 9: (RMAC & MMAC Ports)  
Bit [0]  
Bit [1]  
Flow Control  
0 - Enable (Default)  
1 - Disable  
Duplex Mode  
0 - Full Duplex (Default)  
1 - Half Duplex - Only in 10/100 mode  
73  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [2]  
Speed  
0 - 100 Mbps (Default)  
1 - 10 Mbps  
Bits [4:3] 00 - Enable Auto-Negotiation (Default)  
This enables hardware state machine for auto-negotiation.  
01 - Limited Disable Auto-Negotiation  
This disables hardware state machine for speed auto-negotiation (use  
ECR1Pn[2:0] for configuration). Hardware will still poll PHY for link status.  
10 - Force Link Down  
Disable the port. Hardware does not talk to PHY.  
11 - Force Link Up  
The configuration in ECR1Pn[2:0] is used for (speed/duplex/flow control)  
setup. Hardware does not talk to PHY.  
Bit [5]  
Asymmetric Flow Control Enable.  
0 – Disable asymmetric flow control (Default)  
1 – Enable Asymmetric flow control  
When this bit is set and flow control is on (bit [0] = 0), the device does not send out  
flow control frames, but it’s receiver interprets and processes flow control frames.  
Bits [7:6] SS - Spanning tree state (IEEE 802.1D spanning tree protocol)  
00 - Blocking:  
01 - Listening:  
10 - Learning:  
Frame is dropped  
Frame is dropped  
Frame is dropped. Source MAC address is learned.  
11 - Forwarding: Frame is forwarded. Source MAC address is learned. (Default)  
74  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Port 8: (CPU Port)  
8/16-bit or Serial Only Modes  
Bit [5:0] Reserved  
Bits [7:6] SS - Spanning tree state (IEEE 802.1D spanning tree protocol)  
00 - Blocking:  
01 - Listening:  
10 - Learning:  
Frame is dropped  
Frame is dropped  
Frame is dropped. Source MAC address is learned.  
11 - Forwarding: Frame is forwarded. Source MAC address is learned. (Default)  
Serial + MII Mode  
Bit [0]  
Flow Control  
0 - Enable (Default)  
1 - Disable  
Bit [1]  
Bit [2]  
Duplex Mode  
Must be 0 - Full Duplex (Default)  
Speed  
0 - 100 Mbps (Default)  
1 - 10 Mbps  
Bit [3]  
1 - MII Port Up  
The configuration in ECR1Pn[2:0] is used for (speed/duplex/flow control)  
setup.  
0 - MII Port Down  
Note: Bit [4] must be ‘1’.  
Must be ‘1’.  
Bit [4]  
Bit [5]  
Asymmetric Flow Control Enable.  
0 – Disable asymmetric flow control (Default)  
1 – Enable Asymmetric flow control  
When this bit is set and flow control is on (bit [0] = 0), the device does not send out  
flow control frames, but it’s receiver interprets and processes flow control frames.  
Bits [7:6] SS - Spanning tree state (IEEE 802.1D spanning tree protocol)  
00 - Blocking:  
01 - Listening:  
10 - Learning:  
Frame is dropped  
Frame is dropped  
Frame is dropped. Source MAC address is learned.  
11 - Forwarding: Frame is forwarded. Source MAC address is learned. (Default)  
12.3.1.2 ECR2Pn: Port n Control Register  
I²C Address: h00A+n; CPU Address: h0001+2n (n = port number)  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Filter untagged frame  
0: Disable (Default)  
1: All untagged frames from this port are discarded or follow security option when  
security is enable  
75  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [1]:  
Filter Tag frame  
0: Disable (Default)  
1: All tagged frames from this port are discarded or follow security option when  
security is enable  
Bit [2]:  
Bit [3]:  
Learning Disable  
0: Learning is enabled on this port (Default)  
1: Learning is disabled on this port  
Rate control timer select (RMAC ports only)  
0: 10 microsecond refreshing time (Default)  
1: 1 millisecond refreshing time  
Bit [4]  
Bit [5]  
0
Do not change VLAN tag. This overrides PVMAPnn_3 bit [2]. If this bit is set, no  
tag will be replaced nor removed.  
0: Disable (Default)  
1: Enable  
Bits [7:6] Security Enable. The ZL50409 checks the incoming data for one of the following  
conditions:  
If the source MAC address of the incoming packet is in the MAC table and is  
defined as secure address but the ingress port is not the same as the port  
associated with the MAC address in the MAC table.  
A MAC address is defined as secure when its entry at MAC table has  
static status and bit 0 is set to 1. MAC address bit 0 (the first bit  
transmitted) indicates whether the address is unicast or multicast. As  
source addresses are always unicast bit 0 is not used (always 0).  
ZL50409 uses this bit to define secure MAC addresses.  
If the port is set as learning disable and the source MAC address of the  
incoming packet is not defined in the MAC address table or the MAC  
address is not associated to the ingress port.  
If any one of the conditions is met, the packet is forwarded based on these setting.  
00 – Disable port security, forward packets as usual. (Default)  
01 – Discard violating packets  
10 – Forward violating packets as usual and also to the CPU for inspection  
11 – Forward violating packets to the CPU for inspection  
It also checks for one of the following additional conditions:  
If the port is configured to filter untagged frames and an untagged frame  
arrives, or  
If the port is configured to filter tagged frames and a tagged frame arrives, or  
If the packet has the source mac address on the source mac address filter  
list, or  
If the packet has the destination mac address on the destination mac  
address filter list  
If any one of the conditions is met, the packet will be handled according to:  
0X – Discard violating packets  
1X – Forward violating packets to CPU for inspection  
76  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.1.3 ECR3Pn: Port n Control Register  
I²C Address: h014+n; CPU Address: h0080+2n (n = port number)  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Enable receiving short frame < 64B  
0: Disable (Default)  
1: Allow receiving short frame with correct CRC.  
Enable receiving long frame > 1522  
0: Disable (Default)  
1: Allow receiving long frame that are <= BUF_LIMIT value  
Enable pad frame to 64B when transmitted  
0: Allow padding to 64B (Default)  
1: Disable  
Enable compress preamble  
0: Send standard preamble (Default)  
1: Only one byte preamble+SFD  
Bits [6:4] Number of bytes removed from the Inter-Frame Gap (IFG). (Default 0x0)  
Bit [7]  
Link Heart Beat Transmit (RMAC ports only)  
0: Disable (Default)  
1: Enable  
12.3.1.4 ECR4Pn: Port n Control Register  
I²C Address: h01E+n; CPU Address: h0081+2n (n = port number)  
Accessed by CPU and I²C (R/W)  
Port 0 – 7: (RMAC Ports)  
Bit [1:0]:  
Bit [2]:  
Enable PHY Mode  
00: MAC Mode (Default)  
11: PHY Mode (Reverse MII/GPSI)  
Only valid in MII and GPSI interface modes. In PHY mode, Mn_TXCLK &  
Mn_RXCLK pins becomes outputs.  
Internal loopback.  
0: Disable (Default)  
1: Enable  
In this mode, the packet is looped back in the MAC layer before going out of the  
chip. You must force linkup at full duplex as well.  
External loopback is another level of system diagnostic which involves the PHY  
device to loopback the packet.  
Bits [4:3]: Interface mode:  
00 - GPSI mode  
01 - MII mode  
10 - Reserved  
11 - RMII mode (Default)  
77  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [5]:  
Frame loopback.  
0: Disable frame from sending back to its source port. (Default)  
1: Allow frame to send back to its source port  
In a regular ethernet switch, a packet should never be receive and forwarded to  
the same port. Setting the bit allows it to happen.  
This is not the same as an ingress MAC loopback. The destination MAC address  
has to be stored (learned) in the MCT and associated with the originating source  
port. The frame loopback will only work for unicast packets.  
Bit [6]:  
Bit [7]:  
Link Heart Beat Receive  
0: Disable (Default). Also clears all MAC LHB status.  
1: Enable  
Soft reset.  
0: Normal operation (Default)  
1: Reset. Not self clearing.  
Port 8: (CPU Port)  
Bits [1:0]: Reserved  
Bit [2]:  
Enable special write to 2 registers in a single write operation.  
0: Disable (Default)  
1: Enable  
Should be enabled only in serial mode and disabled in 8/16-bit mode.  
Bits [4:3]: Enable insertion of 2-byte CPU information in CPU frame packet in Serial + MII  
mode  
00: No information is inserted  
01: Insert 2-byte of CPU information  
10: Reserved  
11: Insert 6-byte of padding + 2-byte of CPU information (Default)  
In port-based VLAN mode, the CPU MII interface must be in “No information is  
inserted” mode (ECR4P8[4:3]='00'). In tagged-based VLAN mode, the CPU MII  
interface supports all three modes (0,2,8 bytes insertion).  
Bit [5]:  
Frame loopback.  
0: Disable frame from sending back to its source port. (Default)  
1: Allow frame to send back to its source port  
In a regular ethernet switch, a packet should never be receive and forwarded to  
the same port. Setting the bit allows it to happen.  
This is not the same as an ingress MAC loopback. The destination MAC address  
has to be stored (learned) in the MCT and associated with the originating source  
port. The frame loopback will only work for unicast packets.  
Bit [6]:  
Bit [7]:  
Reserved  
Soft reset.  
0: Normal operation (Default)  
1: Reset. Not self clearing.  
78  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Port 9: (MMAC Port)  
Bits [1:0]: Enable PHY Mode  
00: MAC Mode (Default)  
11: PHY Mode (Reverse MII)  
In PHY mode, M9_RXCLK pin becomes an output and M9_MTXCLK must be tied  
to M9_RXCLK externally.  
Bit [2]:  
Internal loopback.  
0: Disable (Default)  
1: Enable  
In this mode, the packet is looped back in the MAC layer before going out of the  
chip. You must force linkup at full duplex as well.  
External loopback is another level of system diagnostic which involves the PHY  
device to loopback the packet.  
Bits [4:3]: Interface mode:  
11 - MII mode (Default)  
Bit [5]:  
Frame loopback.  
0: Disable frame from sending back to its source port. (Default)  
1: Allow frame to send back to its source port  
In a regular ethernet switch, a packet should never be receive and forwarded to  
the same port. Setting the bit allows it to happen.  
This is not the same as an ingress MAC loopback. The destination MAC address  
has to be stored (learned) in the MCT and associated with the originating source  
port. The frame loopback will only work for unicast packets.  
Bit [6]:  
Bit [7]:  
Reserved  
Soft reset.  
0: Normal operation (Default)  
1: Reset. Not self clearing.  
12.3.1.5 BUF_LIMIT – Frame Buffer Limit  
CPU Address: h0036  
Accessed by CPU (R/W)  
Bits [6:0]: Frame Buffer Limit (max 4 KB). Multiple of 64 bytes (Default 0x40)  
Bit [7]:  
Reserved  
12.3.1.6 FCC – Flow Control Grant Period  
CPU Address: h0037  
Accessed by CPU (R/W)  
Bits [2:0]:  
Flow Control Grant Period. (Default 0x3)  
Units are (FCC[2:0]+1)*4us  
Reserved  
Bits [7:3]:  
79  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.2 (Group 1 Address) VLAN Group  
12.3.2.1 AVTCL – VLAN Type Code Register Low  
I²C Address: h028; CPU Address: h0100  
Accessed by CPU and I²C (R/W)  
Bits [7:0]: VLANType_LOW: Lower 8 bits of the VLAN type code (Default 0x00)  
12.3.2.2 AVTCH – VLAN Type Code Register High  
I²C Address: h029; CPU Address: h0101  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
VLANType_HIGH: Upper 8 bits of the VLAN type code (Default is 0x81)  
12.3.2.3 PVMAP00_0 – Port 0 Configuration Register 0  
I²C Address: h02A, CPU Address: h0102  
Accessed by CPU and I²C (R/W)  
In Port Based VLAN Mode  
Bits [7:0]:  
VLAN Mask for port 0 (Default 0xFF)  
This register indicates the legal egress ports. A “1” on bit 3 means that the packet can be sent to port 3. A “0” on bit  
3 means that any packet destined to port 3 will be discarded. This register works with registers 1 to form a 10 bit  
mask to all egress ports.  
In Tag based VLAN Mode  
Bits [7:0]:  
PVID [7:0] (Default is 0xFF)  
This is the default VLAN tag. It works with configuration register PVMAP00_1 [7:5] [3:0] to form a default VLAN tag.  
If the received packet is untagged, then the packet is classified with the default VLAN tag. If the received packet has  
a VLAN ID of 0, then PVID is used to replace the packet’s VLAN ID.  
12.3.2.4 PVMAP00_1 – Port 0 Configuration Register 1  
I²C Address: h034, CPU Address: h0103  
Accessed by CPU and I²C (R/W)  
In Port based VLAN Mode  
Bits [1:0]:  
Bits [7:2]:  
VLAN Mask for ports 9 to 8 (Default 0x3)  
Reserved (Default 0x3F)  
80  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
In Tag based VLAN Mode  
Bits [3:0]:  
Bit [4]:  
PVID [11:8] (Default is 0xF)  
Untrusted Port.  
This register is used to change the VLAN priority field of a packet to a  
predetermined priority.  
1: VLAN priority field is changed to Bit [7:5] at ingress port (Default)  
0: Keep VLAN priority field  
Bits [7:5]:  
Untag Port Priority (Default 0x7)  
Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
12.3.2.5 PVMAP00_3 – Port 0 Configuration Register 3  
I²C Address: h3E, CPU Address: h0105  
Accessed by CPU and I²C (R/W)  
In Port Based VLAN Mode  
Bits [2:0]:  
Bits [5:3]:  
Reserved  
Default transmit priority. Used when Bit [7]=1 (Default 0)  
Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
Bit [6]:  
Bit [7]:  
Default drop precedence. Used when Bit [7]=1  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Enable Fix Priority (Default 0)  
0 - Disable. All frames are analysed. Transmit Priority and Drop Precedence are  
based on VLAN Tag, TOS or Logical Port.  
1 - Enable. Transmit Priority and Drop Precedence are based on values  
programmed in bit [6:3]  
In Tag-based VLAN Mode  
Bit [0]:  
Bit [1]:  
Not used  
Ingress Filter Enable  
0 - Disable Ingress Filter. Packets with VLAN not belonging to source port are  
forwarded, if destination port belongs to the VLAN. Symmetric VLAN. (Default)  
1 - Enable Ingress Filter. Packets with VLAN not belonging to source port are  
filtered. Asymmetric VLAN.  
81  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [2]:  
Force untag out (VLAN tagging is based on IEEE 802.1Q rule).  
0 - Disable (Default)  
1 - Force untagged output. All packets transmitted from this port are untagged.  
This bit is used when this port is connected to legacy equipment that does not  
support VLAN tagging.  
Bits [5:3]:  
Default transmit priority. Used when Bit [7]=1 (Default 0)  
Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
Bit [6]:  
Bit [7]:  
Default drop precedence. Used when Bit [7]=1  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Enable Fix Priority (Default 0)  
0 - Disable. All frames are analysed. Transmit Priority and Drop Precedence are  
based on VLAN Tag, TOS or Logical Port.  
1 - Enable. Transmit Priority and Drop Precedence are based on values  
programmed in bit [6:3]  
12.3.2.6 PVMAPnn_0,1,3 – Ports 1~9 Configuration Registers  
PVMAP01_0,1,3 - I²C Address h02B, 035, 03F; CPU Address:h0106, 0107, 0109 (Port 1)  
PVMAP02_0,1,3 - I²C Address h02C, 036, 040; CPU Address:h010A, 010B, 010D (Port 2)  
PVMAP03_0,1,3 - I²C Address h02D, 037, 041; CPU Address:h010E, 010F, 0111 (Port 3)  
PVMAP04_0,1,3 - I²C Address h02E, 038, 042; CPU Address:h0112, 0113, 0115 (Port 4)  
PVMAP05_0,1,3 - I²C Address h02F, 039, 043; CPU Address:h0116, 0117, 0119 (Port 5)  
PVMAP06_0,1,3 - I²C Address h030, 03A, 044; CPU Address:h011A, 011B, 011D (Port 6)  
PVMAP07_0,1,3 - I²C Address h031, 03B, 045; CPU Address:h011E, 011F, 0121 (Port 7)  
PVMAP08_0,1,3 - I²C Address h032, 03C, 046; CPU Address:h0122, 0123, 0125 (Port CPU)  
PVMAP09_0,1,3 - I²C Address h033, 03D, 047; CPU Address:h0126, 0127, 0129 (Port MMAC)  
12.3.2.7 PVMODE  
I²C Address: h048, CPU Address: h0170  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
VLAN Mode  
0: Port based VLAN Mode (Default)  
1: Tag based VLAN Mode  
Bit [1]:  
Slow learning (Default = 0)  
Same function as SE_OPMODE bit [7]. Either bit can enable the function; both need to  
be turned off to disable the feature.  
82  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [2]:  
Disable dropping of frames with destination MAC addresses 01-80-C2-00-00-01 to  
0x01-80-C2-00-00-0F.  
0: Drop all frames in this range (Default)  
1: Disable dropping of frames in this range  
Bit [3]:  
Bit [4]:  
Flooding control in secure mode  
0: Enable - Learning disabled port will not receive any flooding packets (Default)  
1: Disable  
Support MAC address 0  
0: MAC address 0 is not learned. (Default)  
This means packet with destination MAC address 0 is forwarded as unknown  
destination. It is subjected to unicast to multicast rate control.  
1: MAC address 0 is learned.  
Bit [5]:  
Disable IEEE multicast control frame (01-80-C2-00-00-00 to 01-80-C2-00-00-0F) to  
CPU in managed mode. In unmanaged mode, frame is forwarded as multicast (except  
PAUSE frame).  
0: Frame is forwarded to CPU (Default)  
1: Frame is forwarded as multicast (except PAUSE frame)  
Bit [6]:  
Bit [7]:  
IP Multicast Enable  
0: Disable (default)  
1: Enable  
In general, this bit is equal to ^FEN[4].  
Enable logical port match in secure mode  
0: Disable (Default)  
1: Enable - When Well Known or User Define logical port force discard enabled, force  
any IP packet with logical port number matching logical port numbers to CPU.  
12.3.3 (Group 2 Address) Port Trunking Groups  
Trunk Group – Up to eight RMAC ports can be selected for each trunk group.  
12.3.3.1 TRUNKn– Trunk Group 0~7  
CPU Address: h0200+n (n = trunk group)  
Accessed by CPU (R/W)  
Bit [7:0] Port 7-0 bit map of trunk n. (Default 0)  
B
i
t
B
i
t
7
0
TRUNK0  
P
o
r
P
o
r
t
t
7
0
83  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.3.2 TRUNKn_HASH10 – Trunk group n hash result 1/0 destination port number  
CPU Address: h0208+4n (n = trunk group)  
Accessed by CPU (R/W)  
Bits [3:0]  
Bits [7:4]  
Hash result 0 destination port number (Default 0)  
Hash result 1 destination port number (Default 0)  
12.3.3.3 TRUNKn_HASH32 – Trunk group n hash result 3/2 destination port number  
CPU Address: h0209+4n (n = trunk group)  
Accessed by CPU (R/W)  
Bits [3:0]  
Bits [7:4]  
Hash result 2 destination port number (Default 0)  
Hash result 3 destination port number (Default 0)  
12.3.3.4 TRUNKn_HASH54 – Trunk group n hash result 5/4 destination port number  
CPU Address: h020A+4n (n = trunk group)  
Accessed by CPU (R/W)  
Bits [3:0]  
Bits [7:4]  
Hash result 4 destination port number (Default 0)  
Hash result 5 destination port number (Default 0)  
12.3.3.5 TRUNKn_HASH76 – Trunk group n hash result 7/6 destination port number  
CPU Address: h020B+4n (n = trunk group)  
Accessed by CPU (R/W)  
Bits [3:0]  
Bits [7:4]  
Hash result 6 destination port number (Default 0)  
Hash result 7 destination port number (Default 0)  
Multicast Hash Registers  
Multicast Hash registers are used to distribute multicast traffic. 16 registers are used to form a 8-entry array; each  
entry has 10 bits, with each bit representing one port. Any port not belonging to a trunk group should be  
programmed with 1. Ports belonging to the same trunk group should only have a single port set to “1” per entry. The  
port set to “1” is picked to transmit the multicast frame when the hash value is met.  
84  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Hash Value =0 HASH0-1  
HASH0-0  
HASH1-0  
HASH2-0  
HASH3-0  
HASH4-0  
HASH5-0  
HASH6-0  
HASH7-0  
Hash Value =1 HASH1-1  
Hash Value =2 HASH2-1  
Hash Value =3 HASH3-1  
Hash Value =4 HASH4-1  
Hash Value =5 HASH5-1  
Hash Value =6 HASH6-1  
Hash Value =7 HASH7-1  
P
o
r
P P  
P
o
r
o o  
r
t
r
t
t
t
9
8 7  
0
12.3.3.6 MULTICAST_HASHn-0 – Multicast hash result 0~7 mask byte 0  
CPU Address: h0228+2n (n = hash value)  
Accessed by CPU (R/W)  
Bits [7:0]:  
Port 7-0 bit map for multicast hash. (Default 0xFF)  
12.3.3.7 MULTICAST_HASHn-1 – Multicast hash result 0~7 mask byte 1  
CPU Address: h0229+2n (n = hash value)  
Accessed by CPU (R/W)  
Bits [1:0]: Port 9-8 bit map for multicast hash. (Default 0x3)  
Bit [2]:  
Reserved (Default 0x1)  
Bits [5:3]: Reserved (Default 0x7)  
Bits [7:6]: MULTICAST_HASH0-1  
Hash Select. The hash algorithm selected is valid for all trunks  
00 - Use Source and Destination MAC Address for hashing  
01 - Use Source MAC Address for hashing  
10 - Use Destination MAC Address for hashing  
11 - Use Source Port Number for hashing (Default)  
MULTICAST_HASH[7:1]-1  
Reserved (Default 0x3)  
85  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4 (Group 3 Address) CPU Port Configuration Group  
47  
0
(MC bit)  
MAC5  
MAC4  
MAC3  
MAC2  
MAC1  
MAC0  
MAC5 to MAC0 registers form the CPU MAC address. When a packet with destination MAC address match MAC  
[5:0], the packet is forwarded to the CPU. The default MAC address is 00-00-00-00-00-00.  
12.3.4.1 MAC0 – CPU MAC address byte 0  
CPU Address: h0300  
Accessed by CPU (R/W)  
Bits [7:0]:  
Byte 0 (bits [7:0]) of the CPU MAC address (Default 0)  
12.3.4.2 MAC1 – CPU MAC address byte 1  
CPU Address: h0301  
Accessed by CPU (R/W)  
Bits [7:0]: Byte 1 (bits [15:8]) of the CPU MAC address (Default 0)  
12.3.4.3 MAC2 – CPU MAC address byte 2  
CPU Address: h0302  
Accessed by CPU (R/W)  
Bits [7:0]: Byte 2 (bits [23:16]) of the CPU MAC address (Default 0)  
12.3.4.4 MAC3 – CPU MAC address byte 3  
CPU Address: h0303  
Accessed by CPU (R/W)  
Bits [7:0]:  
Byte 3 (bits [31:24]) of the CPU MAC address (Default 0)  
12.3.4.5 MAC4 – CPU MAC address byte 4  
CPU Address: h0304  
Accessed by CPU (R/W)  
Bits [7:0]: Byte 4 (bits [39:32]) of the CPU MAC address (Default 0)  
86  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4.6 MAC5 – CPU MAC address byte 5  
CPU Address: h0305  
Accessed by CPU (R/W)  
Bits [7:0]: Byte 5 (bits [47:40]) of the CPU MAC address (Default 0)  
Note: Bits [42:40] are set on a per port basis using MAC01, MAC23, MAC45,  
MAC67 registers. For port 9, this register is ignored and MAC9 is used for bits  
[47:40].  
12.3.4.7 INT_MASK0 – Interrupt Mask  
CPU Address: h0306  
Accessed by CPU (R/W)  
The CPU can dynamically mask the interrupt when it is busy and doesn’t want to be interrupted. (Default 0x00)  
-
-
1: Mask the interrupt  
0: Unmask the interrupt (Enable interrupt) (Default)  
Bit [0]:  
Bit [1]:  
Bit [2]:  
CPU frame interrupt. CPU frame buffer has data for CPU to read  
Control Command 1 interrupt. Control Command Frame buffer1 has data for CPU to read  
Control Command 2 interrupt. Control command Frame buffer2 has data for CPU to read  
Bits [6:3]: Reserved  
Bit [7]: Device Timeout Detected interrupt  
12.3.4.8 INTP_MASK0 – Interrupt Mask for MAC Port 0,1  
CPU Address: h0310  
Accessed by CPU (R/W)  
The CPU can dynamically mask the interrupt when it is busy and doesn’t want to be interrupted (Default 0x00)  
-
-
1: Mask the interrupt  
0: Unmask the interrupt (Default)  
Bit [0]: Port 0 statistic counter wrap around interrupt mask. An Interrupt is generated when a statistic  
counter wraps around. Refer to hardware statistic counter for interrupt sources  
Bit [1]: Port 0 link change mask  
Bit [2]: Port 0 module detect mask  
Bit [3]: Reserved  
Bit [4]: Port 1 statistic counter wrap around interrupt mask. An interrupt is generated when a statistic  
counter wraps around. Refer to hardware statistic counter for interrupt sources.  
Bit [5]: Port 1 link change mask  
Bit [6]: Port 1 module detect mask  
Bit [7]  
Reserved  
87  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4.9 INTP_MASKn – Interrupt Mask for MAC Ports 2~9 Registers  
INTP_MASK1 - CPU Address: h0311 (Ports 2,3)  
INTP_MASK2 - CPU Address: h0312 (Ports 4,5)  
INTP_MASK3 - CPU Address: h0313 (Ports 6,7)  
INTP_MASK4 - CPU Address: h0314 (Port CPU,MMAC)  
12.3.4.10 RQS – Receive Queue Select  
CPU Address: h0323  
Accessed by CPU (RW)  
Select which receive queue is being used by the CPU port.  
Bit [0]:  
Select Queue 0  
0: Not selected (Default)  
1: Selected  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Select Queue 1  
Select Queue 2  
Select Queue 3  
Select Multicast Queue 0  
Select Multicast Queue 1  
Select Multicast Queue 2  
Select Multicast Queue 3  
Note: Strict priority applies between different selected queues (UQ3>UQ2>UQ1>UQ0>MQ3>MQ2>MQ1>MQ0).  
12.3.4.11 RQSS – Receive Queue Status  
CPU Address: h0324  
Accessed by CPU (RO)  
CPU receive queue status  
Bits [3:0]:  
Bits [7:4]:  
Unicast Queue 3 to 0 not empty  
0: Empty  
1: Not Empty  
Multicast Queue 3 to 0 not empty  
88  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4.12 MAC01 – Increment MAC port 0,1 address  
CPU Address: h0325  
Accessed by CPU (RW)  
Bits [2:0]:  
Bit [3]:  
Bits [42:40] of Port 0 CPU MAC address  
Reserved  
Bits [6:4]:  
Bit [7]:  
Bits [42:40] of Port 1 CPU MAC address  
Reserved  
MAC01, MAC23, MAC45, MAC67, and MAC9 registers are used with the MAC0~5 registers to form the CPU MAC  
address on a per port basis.  
12.3.4.13 MAC23 – Increment MAC port 2,3 address  
CPU Address: h0326  
Accessed by CPU (RW)  
Bits [2:0]: Bits [42:40] of Port 2 CPU MAC address  
Bit [3]:  
Bits [6:4]: Bits [42:40] of Port 3 CPU MAC address  
Bit [7]: Reserved  
Reserved  
12.3.4.14 MAC45 – Increment MAC port 4,5 address  
CPU Address: h0327  
Accessed by CPU (RW)  
Bits [2:0]:  
Bit [3]:  
Bits [42:40] of Port 4 CPU MAC address  
Reserved  
Bits [6:4]:  
Bit [7]:  
Bits [42:40] of Port 5 CPU MAC address  
Reserved  
12.3.4.15 MAC67 – Increment MAC port 6,7 address  
CPU Address: h0328  
Accessed by CPU (RW)  
Bits [2:0]:  
Bit [3]:  
Bits [42:40] of Port 6 CPU MAC address  
Reserved  
Bits [6:4]:  
Bit [7]:  
Bits [42:40] of Port 7 CPU MAC address  
Reserved  
89  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4.16 MAC9 – Increment MAC port 9 address  
CPU Address: h0329  
Accessed by CPU (RW)  
Bits [7:0]:  
Bits [47:40] of Port 9 CPU MAC address  
12.3.4.17 CPUQINS0 - CPUQINS6 – CPU Queue Insertion Command  
CPU Address: h0330-0336  
Accessed by CPU, (R/W)  
55  
0
CQ6  
CQ5  
CQ4  
CQ3  
CQ2  
CQ1  
CQ0  
CPU Queue insertion command  
CPUQINS0  
Bit[7:0]:  
Destination Map (port 7-0).  
CPUQINS1  
Bit[9:8]:  
Destination Map (MMAC, CPU).  
Priority  
Bits [13:10]  
Bits [15:14]  
CPUQINS2  
Bits [20:16]  
Bits [23:21]  
CPUQINS3  
Bits [31:24]  
CPUQINS4  
Bits [35:32]  
Bits [39:36]  
CPUQINS5  
Bits [47:40]  
CPUQINS6  
Bits [50:48]  
Bit [51]  
Number of granules for the frame  
Number of granules for the frame (con’t)  
Tail pointer  
Tail pointer (con’t)  
Tail pointer (con’t)  
Header Pointer  
Header Pointer (con’t)  
Header Pointer (con’t)  
Multicast frame (has to be one if more than one destination port)  
Reserved  
Bits [54:52]  
Bit [55]  
Command valid (will be processed on the rising edge of the signal)  
90  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4.18 CPUQINSRPT – CPU Queue Insertion Report  
CPU Address: h0337  
Accessed by CPU, (RO)  
CPU command queue status  
The command is under processing.  
Bit [0]:  
Bit [1]:  
Insertion Fail (May be due to queue full, WRED or filtering)  
12.3.4.19 CPUGRNHDL0 - CPUGRNHDL1 – CPU Allocated Granule Pointer  
CPU Address: h0338-339  
Accessed by CPU, (RO)  
15  
0
CG1  
CG0  
CPU Queue insertion command  
Granule pointer.  
Pointer valid  
Bits [14:0]:  
Bit [15]:  
12.3.4.20 CPURLSINFO0 - CPURLSINFO4 – Receive Queue Status  
CPU Address: h033A-033E  
Accessed by CPU, (R/W)  
0
CR4  
CR3  
CR2  
CR1  
CR0  
CPU Queue insertion command  
Header pointer  
Tail pointer  
Bits [14:0]:  
Bits [30:15]  
Bits [38:32]  
Number of granules for the release  
91  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.4.21 CPUGRNCTR – CPU Granule Control  
CPU Address: h033f  
Accessed by CPU, (R/W)  
CPU receive queue status  
Allocate granule to the CPU if set to one. Otherwise, do not allocate any resource.  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Read allocated granule (at rising edge only)  
Release info valid (will be processed at rising edge only)  
12.3.5 (Group 4 Address) Search Engine Group  
12.3.5.1 AGETIME_LOW – MAC address aging time Low  
I²C Address: h049; CPU Address: h0400  
Accessed by CPU and I²C (R/W)  
Used in conjuction with AGETIME_HIGH. The ZL50409 removes the MAC address from the data base and sends a  
Delete MAC Address Control Command to the CPU.  
Bits [7:0]:  
Low byte of the MAC address aging timer (Default 0x5C)  
12.3.5.2 AGETIME_HIGH –MAC address aging time High  
I²C Address: h04A; CPU Address: h0401  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
High byte of the MAC address aging timer (Default 0x00)  
The default setting of AGETIME_LOW/HIGH provides 300 seconds aging time. Aging time is based on the  
following equation:  
{AGETIME_HIGH,AGETIME_LOW} X (# of MAC entries in the memory X 800 µsec). Number of MAC entries = 4 K.  
12.3.5.3 SE_OPMODE – Search Engine Operation Mode  
CPU Address: h0403  
Accessed by CPU (R/W)  
Note: ECR2[2] enable/disable learning for each port.  
Bit [0]:  
Bit [1]:  
Reserved. Must be 0.  
Protocol filtering mode  
0 – Inclusive (Default)  
1 – Exclusive  
92  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [2]:  
Bit [3]:  
Delete MAC report control  
0 – Report MAC address deletion (MAC address is deleted from MCT after  
aging time) (Default)  
1 – Disable report MAC address deletion  
Delete Control  
0 – MAC address entry is removed when it is old enough to be aged (Default)  
1 – Disable aging logic from removing MAC during aging  
However, a report is still sent to the CPU in both cases, when bit [2] = 0  
Bit [4]:  
Enable RSVP Packet trapping  
0 - Disable RSVP Packet trapping. (Default)  
1 - Enable RSVP Packet trapping. IP Multicast also needs to be enabled for  
this function.  
Bit [5]  
Reserved  
Bit [6]:  
Disable MCT speed-up aging  
0 – Enable speed-up aging when MCT resource is low. (Default)  
1 – Disable speed-up aging when MCT resource is low.  
Bit [7]:  
Slow Learning  
0 – Learning is performed independent of search demand (Default)  
1 – Enable slow learning. Learning is temporary disabled when search  
demand is high  
12.3.6 (Group 5 Address) Buffer Control/QOS Group  
12.3.6.1 QOSC – QOS Control  
I²C Address: h04B; CPU Address: h0500  
Accessed by CPU and I2C (R/W)  
Bit [0]:  
Enable TX rate control (on RMAC ports only)  
0 – Disable (Default)  
1 – Enable  
Bit [1]:  
Enable RX rate control (on RMAC ports only)  
0 – Disable (Default)  
1 – Enable  
Bits [4:2]:  
Bit [5]:  
Reserved  
Select VLAN tag or TOS (IP packets) to be preferentially picked to map  
transmit priority and drop precedence  
0 – Select VLAN Tag priority field over TOS (Default)  
1 – Select TOS over VLAN tag priority field  
Bit [6]:  
Bit [7]:  
Select TOS bits for transmission priority  
0 – Use TOS [4:2] bits to map the transmit priority (Default)  
1 – Use TOS [7:5] bits to map the transmit priority  
Select TOS bits for drop precedence  
0 – Use TOS [4:2] bits to map the drop precedence (Default)  
1 – Use TOS [7:5] bits to map the drop precedence  
93  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.6.2 PCC – Packet Congestion Control  
I2C Address: h068; CPU Address: h0510  
Accessed by CPU and I2C (R/W)  
Bits [7:0]:  
Packet congestion control on the granule count of P0 queue.  
Used to trigger RED at B% when destination port’s P0 queue granule count  
reaches PCC and shared pool is all in use. Granularity is 16 granule (Default  
0x6).  
See Programming QoS Registers application note, ZLAN-42, for more information  
12.3.6.3 MCC – Multicast Congestion Control  
I²C Address: h069; CPU Address: h0511  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Global congestion control on the multicast granule count.  
Used to trigger 100% drop (or flow control, if FC enabled on source port)  
when total multicast granule count reaches MCC. Granularity is 16 granule  
(Default 0x6).  
See Programming QoS Registers application note, ZLAN-42, for more information  
12.3.6.4 MCCTH – Multicast Threshold Control  
CPU Address: h0512  
Accessed by CPU (R/W)  
Global congestion control threshold on the multicast granule count. Exceeding  
Bits [7:0]:  
the MCCTH threshold is considered as an indication of multicast resources being  
low.  
Used to trigger RED at B% when when total multicast granule count reaches  
MCCTH. Granularity is 16 granule (Default 0x3).  
See Programming QoS Registers application note, ZLAN-42, for more information  
12.3.6.5 RDRC0 – WRED Rate Control 0  
I²C Address: h090; CPU Address: h0513  
Accessed by CPU and I2C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Corresponds to the frame drop percentage Y% for WRED. Granularity  
6.25%.  
Corresponds to the frame drop percentage X% for WRED. Granularity  
6.25%.  
See Programming QoS Registers application note, ZLAN-42, for more information  
94  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.6.6 RDRC1 – WRED Rate Control 1  
I²C Address: h091; CPU Address: h0514  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Corresponds to the frame drop percentage B% for RED. Granularity 6.25%.  
Corresponds to the frame drop percentage Z% for WRED. Granularity  
6.25%.  
See Programming QoS Registers application note, ZLAN-42, for more information  
12.3.6.7 RDRC2 – WRED Rate Control 2  
CPU Address: h0515  
Accessed by CPU (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Corresponds to the frame drop percentage RB% for ingress rate control.  
Granularity 6.25%.  
Corresponds to the frame drop percentage RA% for ingress rate control.  
Granularity 6.25%.  
See Rate Control application note, ZLAN-33, for more information  
12.3.6.8 SFCB – Share FCB Size  
I²C Address: h074; CPU Address: h0518  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Expressed in multiples of 16 granules. Buffer reservation for shared pool.  
12.3.6.9 C1RS – Class 1 Reserve Size  
I²C Address: h075; CPU Address: h0519  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Class 1 FCB Reservation  
Buffer reservation for class 1. Granularity 16 granules. (Default 0)  
12.3.6.10 C2RS – Class 2 Reserve Size  
I²C Address: h076; CPU Address: h051A  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Class 2 FCB Reservation  
Buffer reservation for class 2. Granularity 16 granules. (Default 0)  
95  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.6.11 C3RS – Class 3 Reserve Size  
I²C Address: h077; CPU Address: h051B  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Class 3 FCB Reservation  
Buffer reservation for class 3. Granularity 16 granules. (Default 0)  
12.3.6.12 AVPML – VLAN Tag Priority Map  
I²C Address: h056; CPU Address: h0530  
Accessed by CPU and I²C (R/W)  
Registers AVPML, AVPMM, and AVPMH allow the eight VLAN Tag priorities to map into eight Internal level transmit  
priorities. Under the Internal transmit priority, seven is the highest priority where as zero is the lowest. This feature  
allows the user the flexibility of redefining the VLAN priority field. For example, programming a value of 7 into bit 2:0  
of the AVPML register would map packet VLAN priority 0 into Internal transmit priority 7. The new priority is used  
inside the ZL50409. When the packet goes out it carries the original priority.  
Bits [2:0]:  
Priority when the VLAN tag priority field is 0 (Default 0)  
Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
Bits [5:3]:  
Bits [7:6]:  
Priority when the VLAN tag priority field is 1 (Default 0)  
Priority when the VLAN tag priority field is 2 (Default 0)  
12.3.6.13 AVPMM – VLAN Priority Map  
I²C Address: h057; CPU Address: h0531  
Accessed by CPU and I²C (R/W)  
Map VLAN priority into eight level transmit priorities:  
Bit [0]:  
Priority when the VLAN tag priority field is 2 (Default 0)  
Priority when the VLAN tag priority field is 3 (Default 0)  
Priority when the VLAN tag priority field is 4 (Default 0)  
Priority when the VLAN tag priority field is 5 (Default 0)  
Bits [3:1]:  
Bits [6:4]:  
Bit [7]:  
96  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.6.14 AVPMH – VLAN Priority Map  
I²C Address: h058; CPU Address: h0532  
Accessed by CPU and I²C (R/W)  
Map VLAN priority into eight level transmit priorities:  
Bits [1:0]:  
Bits [4:2]:  
Bits [7:5]:  
Priority when the VLAN tag priority field is 5 (Default 0)  
Priority when the VLAN tag priority field is 6 (Default 0)  
Priority when the VLAN tag priority field is 7 (Default 0)  
12.3.6.15 AVDM – VLAN Discard Map  
I²C Address: h05C; CPU Address: h0533  
Accessed by CPU and I²C (R/W)  
Map VLAN priority into frame discard when low priority buffer usage is above threshold  
Bit [0]:  
Frame drop precedence when VLAN Tag priority field is 0 (Default 0)  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Frame drop precedence when VLAN Tag priority field is 1 (Default 0)  
Frame drop precedence when VLAN Tag priority field is 2 (Default 0)  
Frame drop precedence when VLAN Tag priority field is 3 (Default 0)  
Frame drop precedence when VLAN Tag priority field is 4 (Default 0)  
Frame drop precedence when VLAN Tag priority field is 5 (Default 0)  
Frame drop precedence when VLAN Tag priority field is 6 (Default 0)  
Frame drop precedence when VLAN Tag priority field is 7 (Default 0)  
12.3.6.16 TOSPML – TOS Priority Map  
I²C Address: h059; CPU Address: h0540  
Accessed by CPU and I²C (R/W)  
Map TOS field in IP packet into eight level transmit priorities  
Bits [2:0]:  
Priority when the TOS field is 0 (Default 0)  
Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
97  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bits [5:3]:  
Bits [7:6]:  
Priority when the TOS field is 1 (Default 0)  
Priority when the TOS field is 2 (Default 0)  
12.3.6.17 TOSPMM – TOS Priority Map  
I²C Address: h05A; CPU Address: h0541  
Accessed by CPU and I²C (R/W)  
Map TOS field in IP packet into eight level transmit priorities  
Bit [0]:  
Priority when the TOS field is 2 (Default 0)  
Priority when the TOS field is 3 (Default 0)  
Priority when the TOS field is 4 (Default 0)  
Priority when the TOS field is 5 (Default 0)  
Bits [3:1]:  
Bits [6:4]:  
Bit [7]:  
12.3.6.18 TOSPMH – TOS Priority Map  
I²C Address: h05B; CPU Address: h0542  
Accessed by CPU and I²C (R/W)  
Map TOS field in IP packet into eight level transmit priorities:  
Bits [1:0]:  
Bits [4:2]:  
Bits [7:5]:  
Priority when the TOS field is 5 (Default 0)  
Priority when the TOS field is 6 (Default 0)  
Priority when the TOS field is 7 (Default 0)  
12.3.6.19 TOSDML – TOS Discard Map  
I²C Address: h05D; CPU Address: h0543  
Accessed by CPU and I²C (R/W)  
Map TOS into frame discard when low priority buffer usage is above threshold  
Bit [0]:  
Frame drop precedence when TOS field is 0 (Default 0)  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Frame drop precedence when TOS field is 1 (Default 0)  
Frame drop precedence when TOS field is 2 (Default 0)  
Frame drop precedence when TOS field is 3 (Default 0)  
Frame drop precedence when TOS field is 4 (Default 0)  
Frame drop precedence when TOS field is 5 (Default 0)  
98  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [6]:  
Bit [7]:  
Frame drop precedence when TOS field is 6 (Default 0)  
Frame drop precedence when TOS field is 7 (Default 0)  
12.3.6.20 USER_PROTOCOL_n – User Define Protocol 0~7  
I²C Address: h0B3+n; CPU Address: h0550+n  
Accessed by CPU and I²C (R/W)  
(Default 00) This register is duplicated eight times from PROTOCOL 0~7 and allows the CPU to define eight  
separate protocols.  
Bits [7:0]:  
User Define Protocol  
12.3.6.21 USER_PROTOCOL_FORCE_DISCARD – User Define Protocol 0~7 Force Discard  
I²C Address: h0BB; CPU Address: h0558  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Enable Protocol 0 Force Discard  
1 – Enable  
0 – Disable  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Enable Protocol 1 Force Discard  
Enable Protocol 2 Force Discard  
Enable Protocol 3 Force Discard  
Enable Protocol 4 Force Discard  
Enable Protocol 5 Force Discard  
Enable Protocol 6 Force Discard  
Enable Protocol 7 Force Discard  
User Defined Logical Ports and Well Known Ports  
The ZL50409 supports classifying packet priority through layer 4 logical port information. It can be setup by 8 Well  
Known Ports, 8 User Defined Logical Ports, and 1 User Defined Range. The 8 Well Known Ports supported are:  
23  
512  
6000  
443  
111  
22555  
22  
554  
Their respective priority can be programmed via WELL_KNOWN_PORT[7:0]_PRIORITY register.  
WELL_KNOWN_PORT[_ENABLE can individually turn on/off each Well Known Port if desired.  
99  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Similarly, the User Defined Logical Port provides the user programmability to the priority, plus the flexibility to select  
specific logical ports to fit the applications. The 8 User Logical Ports can be programmed via User_Port 0-7  
registers. Two registers are required to be programmed for the logical port number. The respective priority can be  
programmed to the User_Port [7:0] priority register. The port priority can be individually enabled/disabled via  
User_Port_Enable register.  
The User Defined Range provides a range of logical port numbers with the same priority level. Programming is  
similar to the User Defined Logical Port. Instead of programming a fixed port number, an upper and lower limit need  
to be programmed, they are: {RHIGHH, RHIGHL} and {RLOWH, RLOWL} respectively. If the value in the upper limit  
is smaller or equal to the lower limit, the function is disabled. Any IP packet with a logical port that is less than the  
upper limit and more than the lower limit will use the priority specified in RPRIORITY.  
12.3.6.22 WELL_KNOWN_PORT[1:0]_PRIORITY- Well Known Logic Port 1 and 0 Priority  
I²C Address: h0A8; CPU Address: h0560  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Priority setting, transmission + dropping, for Well known port 0 (23 for telnet)  
Bit[0]  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Bits[3:1] Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
Bits [7:4]:  
Priority setting, transmission + dropping, for Well known port 1 (512 for  
TCP/UDP)  
12.3.6.23 WELL_KNOWN_PORT[3:2]_PRIORITY- Well Known Logic Port 3 and 2 Priority  
I²C Address: h0A9; CPU Address: h0561  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Priority setting, transmission + dropping, for Well known port 2 (6000 for  
XWIN)  
Priority setting, transmission + dropping, for Well known port 3 (443 for HTTP  
sec)  
12.3.6.24 WELL_KNOWN_PORT[5:4]_PRIORITY- Well Known Logic Port 5 and 4 Priority  
I²C Address h0AA, CPU Address 562  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Priority setting, transmission + dropping, for Well known port 4 (111 for sun  
remote procedure call)  
100  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bits [7:4]:  
Priority setting, transmission + dropping, for Well known port 5 (22555 for IP  
Phone call setup)  
12.3.6.25 WELL_KNOWN_PORT[7:6]_PRIORITY- Well Known Logic Port 7 and 6 Priority  
I²C Address: h0AB; CPU Address: h0563  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Priority setting, transmission + dropping, for Well known port 6 (22 for ssh)  
Priority setting, transmission + dropping, for Well known port 7 (554 for rtsp)  
12.3.6.26 WELL_KNOWN_PORT_ENABLE – Well Known Logic Port 0 to 7 Enables  
I²C Address: h0AC; CPU Address: h0564  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Enable Well Known Port 0 Priority  
1 – Enable  
0 – Disable  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Enable Well Known Port 1 Priority  
Enable Well Known Port 2 Priority  
Enable Well Known Port 3 Priority  
Enable Well Known Port 4 Priority  
Enable Well Known Port 5 Priority  
Enable Well Known Port 6 Priority  
Enable Well Known Port 7 Priority  
12.3.6.27 WELL_KNOWN_PORT_FORCE_DISCARD – Well Known Logic Port 0~7 Force  
Discard  
I²C Address: h0AD; CPU Address: h0565  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Enable Well Known Port 0 Force Discard  
1 – Enable  
0 – Disable  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Enable Well Known Port 1 Force Discard  
Enable Well Known Port 2 Force Discard  
Enable Well Known Port 3 Force Discard  
Enable Well Known Port 4 Force Discard  
Enable Well Known Port 5 Force Discard  
101  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [6]:  
Bit [7]:  
Enable Well Known Port 6 Force Discard  
Enable Well Known Port 7 Force Discard  
12.3.6.28 USER_PORT[7:0]_[LOW/HIGH] – User Define Logical Port 0~7  
I²C Address: h092+n(Low); CPU Address: h0570+2n(Low) (n = logical port number)  
I²C Address: h09A+n(High); CPU Address: h0571+2n(High)  
Accessed by CPU and I²C (R/W)  
(Default 00) This register is duplicated eight times from PORT 0 through PORT 7 and allows the CPU to define  
eight separate ports.  
7
0
TCP/UDP Logic Port Low  
TCP/UDP Logic Port High  
7
0
12.3.6.29 USER_PORT_[1:0]_PRIORITY - User Define Logic Port 1 and 0 Priority  
I²C Address: h0A2; CPU Address: h0590  
Accessed by CPU and I²C (R/W)  
The chip allows the CPU to define the priority  
Bits [3:0]:  
Priority setting, transmission + dropping, for logic port 0  
Bit[0]  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Bits[3:1] Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
Bits [7:4]:  
Priority setting, transmission + dropping, for logic port 1 (Default 00)  
12.3.6.30 USER_PORT_[3:2]_PRIORITY - User Define Logic Port 3 and 2 Priority  
I²C Address: h0A3; CPU Address: h0591  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Priority setting, transmission + dropping, for logic port 2  
Priority setting, transmission + dropping, for logic port 3 (Default 00)  
102  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.6.31 USER_PORT_[5:4]_PRIORITY - User Define Logic Port 5 and 4 Priority  
I²C Address: h0A4; CPU Address: h0592  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Priority setting, transmission + dropping, for logic port 4  
Priority setting, transmission + dropping, for logic port 5 (Default 00)  
12.3.6.32 USER_PORT_[7:6]_PRIORITY - User Define Logic Port 7 and 6 Priority  
I²C Address: h0A5; CPU Address: h0593  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Priority setting, transmission + dropping, for logic port 6  
Priority setting, transmission + dropping, for logic port 7 (Default 00)  
12.3.6.33 USER_PORT_ENABLE[7:0] – User Define Logic Port 0 to 7 Enables  
I²C Address: h0A6; CPU Address: h0594  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Enable User Port 0 Priority  
1 – Enable  
0 – Disable  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Enable User Port 1 Priority  
Enable User Port 2 Priority  
Enable User Port 3 Priority  
Enable User Port 4 Priority  
Enable User Port 5 Priority  
Enable User Port 6 Priority  
Enable User Port 7 Priority  
12.3.6.34 USER_PORT_FORCE_DISCARD[7:0] – User Define Logic Port 0~7 Force Discard  
I²C Address: h0A7; CPU Address: h0595  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Bit [1]:  
Enable User Port 0 Force Discard  
1 – Enable  
0 – Disable  
Enable User Port 1 Force Discard  
103  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Enable User Port 2 Force Discard  
Enable User Port 3 Force Discard  
Enable User Port 4 Force Discard  
Enable User Port 5 Force Discard  
Enable User Port 6 Force Discard  
Enable User Port 7 Force Discard  
12.3.6.35 RLOWL – User Define Range Low Bit 7:0  
I²C Address: h0AE; CPU Address: h05A0  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Lower 8 bit of the User Define Logical Port Low Range  
12.3.6.36 RLOWH – User Define Range Low Bit 15:8  
I²C Address: h0AF; CPU Address: h05A1  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Upper 8 bit of the User Define Logical Port Low Range  
12.3.6.37 RHIGHL – User Define Range High Bit 7:0  
I²C Address: h0B0; CPU Address: h05A2  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Lower 8 bit of the User Define Logical Port High Range  
12.3.6.38 RHIGHH – User Define Range High Bit 15:8  
I²C Address: h0B1; CPU Address: h05A3  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Upper 8 bit of the User Define Logical Port High Range  
104  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.6.39 RPRIORITY – User Define Range Priority  
I²C Address: h0B2; CPU Address: h05A4  
Accessed by CPU and I²C (R/W)  
RLOW and RHIGH form a range for logical ports to be classified with priority specified in RPRIORITY.  
Bit [0]:  
Drop Precedence (inclusive only)  
0 – Drop Precedence Level 0 (Lowest) (Default)  
1 – Drop Precedence Level 1 (Highest)  
Bits [3:1]  
Transmit Priority (inclusive only)  
Transmit Priority Level 0 (Lowest)  
Transmit Priority Level 1  
...  
Transmit Priority Level 6  
Transmit Priority Level 7 (Highest)  
Bits [5:4]  
Bits [7:6]  
Reserved  
00 - No Filtering  
01 - Exclusive Filtering (x<=RLOW or x>=RHIGH)  
10 - Inclusive Filtering (RLOW<x<RHIGH)  
11 - Invalid  
12.3.7 (Group 6 Address) MISC Group  
12.3.7.1 MII_OP0 – MII Register Option 0  
I²C Address: h0BC; CPU Address: h0600  
Accessed by CPU and I²C (R/W)  
Bits [4:0]:  
Bits [5]  
Vendor specified link status register address (null value means don’t use it)  
(Default 00). This is used if the Linkup bit position in the PHY is non-standard  
Disable jabber detection. This is for HomePNA applications or any serial  
operation slower than 10 Mbps.  
0 = Enable  
1 = Disable  
Bits [6]  
Bit [7]:  
Reserved  
Half duplex flow control feature  
0 = Half duplex flow control always enable  
1 = Half duplex flow control by negotiation  
105  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.7.2 MII_OP1 – MII Register Option 1  
I²C Address: h0BD; CPU Address: h0601  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [7:4]:  
Duplex bit location in vendor specified register  
Speed bit location in vendor specified register  
(Default 00)  
12.3.7.3 FEN – Feature Enable Register  
I²C Address: h0BE; CPU Address: h0602  
Accessed by CPU and I²C (R/W)  
Bit [0]:  
Statistic Counter  
0 – Disable (Default)  
1 – Enable (all ports)  
When statistic counter is enable, an interrupt control frame is generated to  
the CPU, every time a counter wraps around. This feature requires an  
external CPU.  
Bit [1]:  
Bit [2]:  
0
Support DS EF Code.  
0 – Disable (Default)  
1 – Enable (all ports)  
When 101110 is detected in DS field (TOS[7:2]), the frame priority is set for  
110 and drop is set for 0.  
Bit [3]:  
Enable VLAN ID hashing  
0 – Disable (Default)  
1 – Enable  
If this is enabled, the VLAN ID will be used along with the MAC address when  
determining the HASH index for learning/searching. This is to allow  
Independent VLAN Learning (IVL).  
This feature is only applicable in tagged-based VLAN mode  
(PVMODE[0]=’1’). In port-based VLAN mode (PVMODE[0]=’0’), this bit must  
be ‘0’.  
Bit [4]:  
Disable IP Multicast Support  
0 – Enable IP Multicast Support (Must also set PVMODE[6]=1)  
1 – Disable IP Multicast Support (Default)  
When enable, IGMP packets are identified by search engine and are passed  
to the CPU for processing. IP multicast packets are forwarded to the IP  
multicast group members according to the VLAN port mapping table.  
106  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [5]:  
Report to CPU  
0 – Disable (Default)  
1 – Enable  
When disable new VLAN port association report, new MAC address report or  
aging reports are disable for all ports. When enable, register SE_OPMODE is  
used to enable/disable selectively each function.  
Bit [6]:  
Bit [7]:  
MII Management State Machine  
0: Enable (Default)  
1: Disable  
This bit must be set so that there is no contention on the MDIO bus between  
MII Management state machine and MIIC & MIID PHY register accesses.  
MCT Link List structure  
0 – Enable (Default)  
1 – Disable  
12.3.7.4 MIIC0 – MII Command Register 0  
CPU Address: h0603  
Accessed by CPU (R/W)  
Bits [7:0]:  
MII Command Data [7:0]  
Note: Before programming MII command: set FEN[6]; check MIIC3, making sure RDY; then program MII  
command.  
12.3.7.5 MIIC1 – MII Command Register 1  
CPU Address: h0604  
Accessed by CPU (R/W)  
Bits [7:0]:  
MII Command Data [15:8]  
12.3.7.6 MIIC2 – MII Command Register 2  
CPU Address: h0605  
Accessed by CPU (R/W)  
Bits [4:0]  
Bits [6:5]  
REG_AD – Register PHY Address  
OP – Operation code  
“10” for read command  
“01” for write command  
Bits [7]  
Reserved  
107  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.7.7 MIIC3 – MII Command Register 3  
CPU Address: h0606  
Accessed by CPU (R/W)  
Bits [4:0]  
Bit [5]  
PHY_AD – 5-bit PHY address  
Reserved  
Bit [6]  
VALID – Data valid from PHY (Read Only)  
RDY – MII management interface ready (Read Only)  
Bit [7]  
Note: Writing to this register will initiate a serial management cycle to the MII management interface.  
12.3.7.8 MIID0 – MII Data Register 0  
CPU Address: h0607  
Accessed by CPU (RO)  
Bits [7:0]:  
MII Data [7:0]  
12.3.7.9 MIID1 – MII Data Register 1  
CPU Address: h0608  
Accessed by CPU (RO)  
Bits [7:0]:  
MII Data [15:8]  
12.3.7.10 USD – One Micro Second Divider  
CPU Address: h0609  
Accessed by CPU (R/W)  
Bits [5:0]: Divider to get one micro second from M_CLK (only used when not in standard RMII mode)  
In a MII or GPSI system, a 50 MHz M_CLK may not be available. The system designer can  
decide to use another frequency on the M_CLK signal. To compensate for this, this register  
is required to be programmed.  
For example. If 20 MHz is used on M_CLK, to compensate for the difference, this register is  
programmed with 20 to provide 1 usec for internal reference.  
Bits [7:6]: Reserved  
108  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.7.11 DEVICE - Device Mode  
CPU Address: h060A  
Accessed by CPU (R/W)  
Bit [0]:  
Bit [1]:  
Reserved  
CPU Interrupt Polarity  
0: Negative Polarity  
1: Positive Polarity (Default)  
Reserved  
Bits [4:2]:  
Bits [7:5]:  
Device ID (Default 0x0). See application note ZLAN-26, Processor Interface,  
for usage.  
12.3.7.12 CHECKSUM - EEPROM Checksum  
I²C Address: 0FF; CPU Address: h060B  
Accessed by CPU and I²C (R/W)  
Bits [7:0]:  
Checksum content (Default 0)  
This register is used in unmanaged mode only. Before requesting that the ZL50409 updates the EEPROM device,  
the correct checksum needs to be calculated and written into this checksum register.  
The checksum formula is:  
FF  
Σ
I²C register = 0  
i = 0  
When the ZL50409 boots from the EEPROM the checksum is calculated and the value must be zero. If the  
checksum is not zeroed the ZL50409 does not start and pin CHECKSUM_OK is set to zero.  
12.3.7.13 LHBTimer – Link Heart Beat Timeout Timer  
CPU Address: h0610  
Accessed by CPU (R/W)  
In slot time (512 bit time). LHB packet will be sent out to the remote device if no other packet is transmitted in half  
this period. The receiver will trigger LHB timeout interrupt if not receiving any good packet in this period.  
12.3.7.14 LHBReg0, LHBReg1 - Link Heart Beat OpCode  
CPU Address: h0611, h6012  
Accessed by CPU (R/W)  
The LHB frame uses MAC control frame format (same as flow control frame.) The register here defines the  
operation code (we recommend h00-12).  
109  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.7.15 fMACCReg0, fMACCReg1 - MAC Control Frame OpCode  
CPU Address: h0613, h0614  
Accessed by CPU (R/W)  
The registers define the operation code if MAC control frame is forced out by processor.  
12.3.7.16 FCB Base Address Register 0  
I²C Address: h0BF; CPU Address: h0620  
Accessed by CPU and I²C (R/W)  
Bits [7:0]  
FCB Base address bit 7:0 (Default 0)  
12.3.7.17 FCB Base Address Register 1  
I²C Address: h0C0; CPU Address: h0621  
Accessed by CPU and I²C (R/W)  
Bits [7:0]  
FCB Base address bit 15:8 (Default 0x60)  
12.3.7.18 FCB Base Address Register 2  
I²C Address: h0C1; CPU Address: h0622  
Accessed by CPU and I²C (R/W)  
Bits [7:0]  
FCB Base address bit 23:16 (Default 0)  
12.3.8 (Group 7 Address) Port Mirroring Group  
12.3.8.1 MIRROR CONTROL – Port Mirror Control Register  
CPU Address: h070C  
Accessed by CPU (R/W) (Default 00)  
Bits [3:0]:  
Bit [4]  
Destination port to be mirrored to.  
Mirror Flow from MIRROR_SRC_MAC[5:0] to MIRROR_DEST_MAC[5:0]  
Mirror Flow from MIRROR_DEST_MAC[5:0] to MIRROR_SRC_MAC[5:0]  
Mirror when address is destination  
Bit [5]  
Bit [6]:  
Bit [7]:  
Mirror when address is source  
110  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.8.2 MIRROR_DEST_MAC[5:0] – Mirror Destination MAC Address 0~5  
CPU Address: h0700-0705  
Accessed by CPU (R/W)  
DEST_MAC5 DEST_MAC4 DEST_MAC3 DEST_MAC2 DEST_MAC1 DEST_MAC0  
[47:40]  
[39:32]  
[31:24]  
[23:16]  
[15:8]  
[7:0]  
(Default 00)  
(Default 00)  
(Default 00)  
(Default 00)  
(Default 00)  
(Default 00)  
12.3.8.3 MIRROR_SRC _MAC[5:0] – Mirror Source MAC Address 0~5  
CPU Address: h0706-070B  
Accessed by CPU (R/W)  
SRC_MAC5  
SRC_MAC4  
SRC_MAC3  
SRC_MAC2  
SRC_MAC1  
SRC_MAC0  
[47:40]  
[39:32]  
[31:24]  
[23:16]  
[15:8]  
[7:0]  
(Default 00)  
(Default 00)  
(Default 00)  
(Default 00)  
(Default 00)  
(Default 00)  
12.3.8.4 RMII_MIRROR0 – RMII Mirror 0  
CPU Address: h0710  
Accessed by CPU (R/W)  
Bits [2:0]:  
Bit [3]:  
Source port to be mirrored  
Mirror path  
0: Receive  
1: Transmit  
Bits [6:4]:  
Bit [7]:  
Destination port for mirrored traffic  
Mirror enable  
12.3.8.5 RMII_MIRROR1 – RMII Mirror 1  
CPU Address: h0711  
Accessed by CPU (R/W)  
Bits [2:0]:  
Bit [3]:  
Source port to be mirrored  
Mirror path  
0: Receive  
1: Transmit  
Bits [6:4]:  
Bit [7]:  
Destination port for mirrored traffic  
Mirror enable  
111  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.9 (Group 8 Address) Per Port QOS Control  
12.3.9.1 FCRn – Port 0~9 Flooding Control Register  
I²C Address: h04C+n; CPU Address: h0800+n (n = port number)  
Accessed by CPU and I²C (R/W)  
Bits [3:0]:  
Bits [6:4]:  
U2MR: Unicast to Multicast Rate. Units in terms of time base defined in bits  
[6:4]. This is used to limit the amount of flooding traffic from Port n. The value  
in U2MR specifies how many packets are allowed to flood within the time  
specified by bit [6:4]. To disable this function, program U2MR to 0.  
(Default = 0)  
Time Base for Unicast to Multicast, Multicast and Broadcast rate control of  
Port n: (Default = 000)  
000 = 100 us  
001 = 200 us  
010 = 400 us  
011 = 800 us  
100 = 1.6 ms  
101 = 3.2 ms  
110 = 6.4 ms  
111 = 12.8 ms  
Bit [7]:  
Reserved  
12.3.9.2 BMRCn - Port 0~9 Broadcast/Multicast Rate Control  
I²C Address: h05E+n; CPU Address: h0820+n (n = port number)  
Accessed by CPU and I²C (R/W)  
This broadcast and multicast rate defines for Port n, the number of packets allowed to be forwarded within a  
specified time. Once the packet rate is reached, packets will be dropped. To turn off the rate limit, program the field  
to 0. Time base is based on register FCR0 [6:4]  
Bits [3:0]:  
Bits [7:4]:  
Multicast Rate Control. Number of multicast packets allowed within the time defined in  
bits 6 to 4 of the Flooding Control Register (FCRn). (Default 0).  
Broadcast Rate Control. Number of broadcast packets allowed within the time defined  
in bits 6 to 4 of the Flooding Control Register (FCRn). (Default 0)  
12.3.9.3 PR100_n – Port 0~7 Reservation  
I²C Address: h06A+n; CPU Address: h0840+n (n = port number)  
Accessed by CPU and I²C (R/W)  
Expressed in multiples of 16 granules. (Default 0x6)  
12.3.9.4 PR100_CPU – Port CPU Reservation  
I²C Address: h073; CPU Address: h0848  
Accessed by CPU and I²C (R/W)  
Expressed in multiples of 16 granules. (Default 0x6)  
112  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.9.5 PRM – Port MMAC Reservation  
I²C Address: h072; CPU Address: h0849  
Accessed by CPU and I²C (R/W)  
Expressed in multiples of 16 granules. (Default 0x24)  
12.3.9.6 PTH100_n – Port 0~7 Threshold  
I²C Address: h0C2+n; CPU Address: h0860+n (n = port number)  
Accessed by CPU and I²C (R/W)  
Expressed in multiples of 16 granules. More than this number used on a source port will trigger either random drop  
or flow control (Default 0x3)  
12.3.9.7 PTH100_CPU – Port CPU Threshold  
I²C Address: h0CB; CPU Address: h0868  
Accessed by CPU and I²C (R/W)  
Expressed in multiples of 16 granules. More than this number used on a source port will trigger either random drop  
or flow control (Default 0x3)  
12.3.9.8 PTHG – Port MMAC Threshold  
I²C Address: h0CA; CPU Address: h0869  
Accessed by CPU and I²C (R/W)  
Expressed in multiples of 16 granules. More than this number used on a source port will trigger either random drop  
or flow control (Default 0x12)  
12.3.9.9 QOSC00, QOSC01 - Classes Byte Limit port 0  
I²C Address: h078-079; CPU Address: h0880-0881  
Accessed by CPU and I²C (R/W)  
QOSC00 – Port 0 L1 threshold for queue 1  
QOSC01 – Port 0 L2 threshold for queue 1  
Multiple of 16 granules. The two numbers set the two level for WRED on the high priority queue. When the queue  
size exceeds the L1 threshold, received frame will subject to X% (high drop) or Y% (low drop) WRED. When the  
queue size exceeds L2 threshold, received frame will either be filtered (high drop) or subject to Z% WRED.  
12.3.9.10 QOSC02, QOSC15 - Classes Byte Limit port 1-7  
I²C Address: h07A-087; CPU Address: h0882-088F  
Accessed by CPU and I²C (R/W)  
Same as QOSC00, QOSC01 for ports 1-7  
113  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.9.11 QOSC16 - QOSC21 - Classes Byte Limit CPU port  
I2C Address: h088-08D; CPU Address: h0890-0895  
Accessed by CPU and I2C (R/W):  
QOSC16 – Port 8 (CPU) L1 threshold for queue 1  
QOSC17 – Port 8 (CPU) L2 threshold for queue 1  
QOSC18 – Port 8 (CPU) L1 threshold for queue 2  
QOSC19 – Port 8 (CPU) L2 threshold for queue 2  
QOSC20 – Port 8 (CPU) L1 threshold for queue 3  
QOSC21 – Port 8 (CPU) L2 threshold for queue 3  
Multiple of 16 granules. The two numbers set the two level for WRED on the high priority queue. When the queue  
size exceeds the L1 threshold, received frame will subject to X% (high drop) or Y% (low drop) WRED. When the  
queue size exceeds L2 threshold, received frame will either be filtered (high drop) or subject to Z% WRED.  
12.3.9.12 QOSC22 - QOSC27 - Classes Byte Limit MMAC port  
I²C Address: h08E-08F; CPU Address: h0896-089B  
Accessed by CPU and I²C (R/W)  
QOSC22 – Port 9 (uplink) L1 threshold for queue 1  
QOSC23 – Port 9 (uplink) L2 threshold for queue 1  
QOSC24 – Port 9 (uplink) L1 threshold for queue 2  
QOSC25 – Port 9 (uplink) L2 threshold for queue 2  
QOSC26 – Port 9 (uplink) L1 threshold for queue 3  
QOSC27 – Port 9 (uplink) L2 threshold for queue 3  
Multiple of 16 granules. The two numbers set the two level for WRED on the high priority queue. When the queue  
size exceeds the L1 threshold, received frame will subject to X% (high drop) or Y% (low drop) WRED. When the  
queue size exceeds L2 threshold, received frame will either be filtered (high drop) or subject to Z% WRED.  
12.3.9.13 QOSC28 - QOSC31 - Classes WFQ Credit For MMAC  
CPU Address: h089C-089F  
Accessed by CPU (R/W)  
QOSC28 – CREDIT_C00  
QOSC29 – CREDIT_C01  
QOSC30 – CREDIT_C02  
QOSC31 – CREDIT_C03  
Bits [5:0] in QOSC28 through QOSC31 represents one set of WFQ parameters for MMAC port. The granularity of  
the numbers is 1, and their sum must be 64. QOSC31 corresponds to queue 3, that is the highest priority, and  
QOSC27 corresponds to queue 0.  
Default scheduling method will be strict priority across all queues. Only when the bit [7] is set, the queue will be  
scheduled as WFQ. The credit number also works as shaper credit if bit [6] is set. A queue with shaper enabled will  
be scheduled by strict priority when the token is available. The shaper setting override the WFQ (bit [7]) setting.  
Bits [5:0]:  
Bit [6]:  
Class scheduling credit  
Traffic Shaper Enable  
0: Disable  
1: Enable  
114  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Bit [7]:  
Enable WFQ Scheduling  
0: Strict Priority  
1: WFQ  
12.3.9.14 QOSC36 - QOSC39 - Shaper Control Port MMAC  
CPU Address: h08A4-08A7  
Accessed by CPU (R/W)  
QOSC36 – TOKEN_LIMIT_C00  
QOSC37 – TOKEN_LIMIT_C01  
QOSC38 – TOKEN_LIMIT_C02  
QOSC39 – TOKEN_LIMIT_C03  
QOSC36 through QOSC39 represents one set of token limit on the shaper of MMAC port. The granularity of the  
numbers is 64 bytes. The shaper is implemented as leaky bucket and the limit here works as bucket size. Since the  
hardware implementation can keep negative number, the limit can be as small as one and still can transmit  
oversized frame, as long as one byte token is available.  
12.3.10 (Group E Address) System Diagnostic  
NOTE: Device Manufacturing test registers.  
12.3.10.1 DTSRL – Test Output Selection  
CPU Address: h0E00  
Accessed by CPU (R/W)  
Test group selection for testout[7:0].  
12.3.10.2 DTSRM – Test Output Selection  
CPU Address: h0E01  
Accessed by CPU (R/W)  
Test group selection for testout[15:8].  
12.3.10.3 TESTOUT0, TESTOUT1 – Testmux Output [7:0], [15:8]  
CPU Address: h0E02-0E03  
Accessed by CPU (RO)  
12.3.10.4 MASK0-MASK4 – Timeout Reset Mask  
CPU Address: h0E10-E14  
Accessed by CPU (R/W)  
Disable timeout reset on selected state machine status.  
See Programming Timeout Reset application note, ZLAN-41, for more information.  
115  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.10.5 BOOTSTRAP0 – BOOTSTRAP3  
CPU Address: h0E80-E83  
Accessed by CPU (RO)  
31  
23  
15  
0
BT3  
BT2  
BT1  
BT0  
Bits [15:0]:  
Bootstrap value from TSTOUT[15:0]:  
Bit [6:0]: TSTOUT[6:0]  
Bit [8:7]: Invert of TSTOUT[8:7]  
Bit [9]: TSTOUT[11]  
Bit [10]: TSTOUT[9]  
Bit [11]: TSTOUT[10]  
Bit [14:12]: TSTOUT[14:12]  
Bit [15]: Always 0  
Bits [23:16]:  
Bits [31:24]:  
Bootstrap value from M[7:0]_TXEN  
Bit [16]: M0_TXEN  
Bit [17]: M1_TXEN  
...  
Bit [23]: M7_TXEN  
Reserved  
12.3.10.6 PRTFSMST0~9  
CPU Address: h0E90+n  
Accessed by CPU (RO)  
TX FSM NOT idle for 5 sec  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]  
Bit [7]:  
TX FIFO control NOT idle for 5 sec  
RX SFD detection NOT idle for 5 sec  
RXINF NOT idle for 5 sec  
PTCTL NOT idle for 5 sec  
Reserved  
LHB frame detected  
LHB receiving timeout  
116  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.10.7 PRTQOSST0-PRTQOSST7  
CPU Address: h0EA0+n  
Accessed by CPU (RO)  
Source port reservation low  
No source port buffer left  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Unicast congestion detected on best effort (P0) queue  
Reserved  
High priority queue reach L1 WRED level  
High priority queue reach L2 WRED level  
Low priority MC queue full  
High priority MC queue full  
12.3.10.8 PRTQOSST8A, PRTQOSST8B (CPU port)  
CPU Address: h0EA8 – 0EA9  
Accessed by CPU (RO)  
0
15  
PQSTB  
PQSTA  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Bit [8]:  
Bit [9]:  
Bit [10]:  
Bit [11]:  
Bit [12]:  
Bit [13]:  
Source port reservation low  
No source port buffer left  
Unicast congestion detected on best effort (P0) queue  
Reserved  
priority queue 1 reach L1 WRED level  
priority queue 1 reach L2 WRED level  
priority queue 2 reach L1 WRED level  
priority queue 2 reach L2 WRED level  
priority queue 3 reach L1 WRED level  
priority queue 3 reach L2 WRED level  
priority 0 MC queue full  
priority 1 MC queue full  
priority 2 MC queue full  
Priority 3 MC queue full  
Bits [15:14]: Reserved  
117  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.10.9 PRTQOSST9A, PRTQOSST9B (MMAC port)  
CPU Address: h0EAA – 0EAB  
Accessed by CPU (RO)  
0
15  
PQSTB  
PQSTA  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Bit [8]:  
Bit [9]:  
Bit [10]:  
Bit [11]:  
Bit [12]:  
Bit [13]:  
Source port reservation low  
No source port buffer left  
Unicast congestion detected on best effort (P0) queue  
Reserved  
Priority queue 1 reach L1 WRED level  
Priority queue 1 reach L2 WRED level  
Priority queue 2 reach L1 WRED level  
Priority queue 2 reach L2 WRED level  
Priority queue 3 reach L1 WRED level  
Priority queue 3 reach L2 WRED level  
Priority 0 MC queue full  
Priority 1 MC queue full  
Priority 2 MC queue full  
Priority 3 MC queue full  
Bits [15:14]: Reserved  
12.3.10.10 CLASSQOSST  
CPU Address: h0EAC  
Accessed by CPU (RO)  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
No share buffer  
No class 1 buffer  
No class 2 buffer  
No class 3 buffer  
Bits [7:4]: Reserved  
118  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.10.11 PRTINTCTR  
CPU Address: h0EAD  
Accessed by CPU (R/W)  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bit [4]:  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Interrupt when source buffer low  
Interrupt when no source buffer  
Interrupt when UC congest  
Interrupt when L1 WRED level  
Interrupt when L2 WRED level  
Interrupt when MC queue full  
Interrupt when LHB timeout  
Interrupt when no class buffer  
12.3.10.12 QMCTRL0~9  
CPU Address: h0EB0+n  
Accessed by CPU (R/W)  
Bit [0]:  
Bit [1]:  
Suspend port scheduling (no departure)  
Reset queue  
Bits [4:2]: Reserved  
Bit [5]:  
Bit [6]:  
Bit [7]:  
Force out MAC control frame  
Force out XOFF flow control frame  
Force out XON flow control frame  
12.3.10.13 QCTRL  
CPU Address: h0EBA  
Accessed by CPU (R/W)  
Stop QM FSM at idle  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Bit [3]:  
Bits [7:4]:  
Stop MCQ FSM at idle  
Stop new granule grant to any source  
Stop release granule from any source  
Reserved  
119  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.10.14 BMBISTR0, BMBISTR1  
CPU Address: h0EBB - 0EBC  
Accessed by CPU (RO)  
12.3.10.15 BMControl  
CPU Address: h0EBD  
Accessed by CPU (R/W)  
Bits [3:0]: Block Memory redundancy control  
0: Use hardware detected value  
All others: Overwrite the hardware detected memory swap map  
Bits [7:4]: Reserved  
12.3.10.16 BUFF_RST  
CPU Address: h0EC0  
Accessed by CPU (R/W)  
Bits [3:0] Assign a value that the pool to be reset  
0: port 0 pool  
1: port 1 pool  
2: port 2 pool  
3: port 3 pool  
4: port 4 pool  
5: port 5 pool  
6: port 6 pool  
7: port 7 pool  
8: port MMAC pool  
9: shared pool  
10: class 1 pool  
11: class 2 pool  
12: class 3 pool  
13: multicast pool  
14: cpu pool  
15: reserved  
Bit [4]  
Bit [5]  
If this bit is 1, then all the pools are assigned  
Set 1 to reset the pools that are assigned  
Bits [7:6] Reserved  
If CPU wants to reset pools again, CPU has to clear bit 5 and then set bit 5.  
Note: Before CPU doing so, CPU should set QCTRL (CPU Address EBA) bit 2 and bit 3 to one. After reset the  
pools, CPU shall reprogram free granule link list (CPU address EC1, EC2, EC3, EC4, EC5, EC6). Then clear  
QCTRL (EBA).  
120  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.10.17 FCB_HEAD_PTR0, FCB_HEAD_PTR1  
CPU address: h0EC1  
Accessed by CPU (R/W)  
Fcb_head_ptr[7:0]. The head pointer of free granule link that CPU assigns.  
Bits [7:0]  
CPU address: h0EC2  
Accessed by CPU (R/W)  
Fcb_head_ptr[14:8]. The head pointer of free granule link that CPU assigns.  
Set 1 to write  
Bits [6:0]  
Bit [7]  
If CPU wants to write again, CPU has to clear bit 15 and then set bit 15.  
12.3.10.18 FCB_TAIL_PTR0, FCB_TAIL_PTR1  
CPU address: h0EC3  
Accessed by CPU (R/W)  
Bits [7:0]  
Fcb_tail_ptr[7:0]. The tail pointer of free granule link that CPU assigns.  
CPU address: h0EC4  
Accessed by CPU (R/W)  
Bits [6:0]  
Bit [7]  
Fcb_tail_ptr[14:8]. The tail pointer of free granule link that CPU assigns.  
Set 1 to write  
If CPU wants to write again, CPU has to clear bit 15 and then set bit 15.  
12.3.10.19 FCB_NUM0, FCB_NUM1  
CPU address: h0EC5  
Accessed by CPU (R/W)  
Bits [7:0] Fcb_number[7:0]. The total number of granules that CPU assigns.  
CPU address: h0EC6  
Accessed by CPU (R/W)  
Bits [6:0] Fcb_number[14:8]. The total number of granules that CPU assigns.  
Bit [7]  
Set 1 to write  
If CPU wants to write again, CPU has to clear bit 15 and then set bit 15.  
121  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
Note: There are two ways to reprogram the free granules.  
1. CPU links all the granules: CPU writes memory directly, at last write head pointer (address EC1, EC2), tail  
pointer (address EC3, EC4) and granule number (address EC5, EC6).  
2. CPU tells Buffer Manager to link: CPU clear head pointer (address EC1, EC2), clear tail pointer (address EC3,  
EC4), then write granule number that tells Buffer Manager to link (address EC5, EC6).  
12.3.10.20 BM_RLSFF_CTRL  
CPU address: h0EC7  
Accessed by CPU (R/W)  
Bit [0]  
Read BM release FIFO.  
Bits [7:1] Reserved  
The information of BM release FIFO is relocated to registers BM_RLSFF_INFO (address ECD, ECC, ECB, ECA,  
EC9 and EC8). If the FIFO is not empty, CPU can read out the next by setting the bit 0. Read only happens when bit  
0 is changing from 0 to 1.  
12.3.10.21 BM_RSLFF_INFO[5:0]  
CPU address: h0EC8  
Accessed by CPU (RO)  
Bits [7:0] Rls_head_ptr[7:0].  
CPU address: h0EC9  
Accessed by CPU (RO)  
Bits [6:0]  
Bit [7]  
Rls_head_ptr[14:8].  
Rls_tail_ptr[0]  
CPU address: h0ECA  
Accessed by CPU (RO)  
Bits [7:0]  
Rls_tail_ptr[8:1]  
CPU address: h0ECB  
Accessed by CPU (RO)  
Bits [5:0] Rls_tail_ptr[14:9]  
Bits [7:6] Rls_count[1:0]  
122  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
CPU address: h0ECC  
Accessed by CPU (RO)  
Bits [4:0] Rls_count[6:2]  
Bit [5] If 1, then It is multicast packet.  
Bits [7:6] Rls_src_port[1:0[  
CPU address: h0ECD  
Accessed by CPU (RO)  
Bits [1:0] Rls_src_port[3:2]  
Bits [3:2] Class[1:0]  
Bit [4] This release request is from QM directly.  
Bits [7:5] Entries count in release FIFO, 0 means FIFO is empty  
12.3.11 (Group F Address) CPU Access Group  
12.3.11.1 GCR - Global Control Register  
CPU Address: h0F00  
Accessed by CPU (R/W)  
Bit [0]:  
Bit [1]:  
Bit [2]:  
Store configuration (Default = 0)  
Write ‘1’ followed by ‘0’ to store configuration into external EEPROM  
Store configuration and reset (Default = 0)  
Write ‘1’ to store configuration into external EEPROM and reset chip  
Start BIST (Default = 0)  
Write ‘1’ followed by ‘0’ to start the device’s built-in self-test. The result is  
found in the DCR register.  
Bit [3]:  
Bit [4]:  
Soft Reset (Default = 0)  
Write ‘1’ to reset chip  
Initialization Completed (Default = 0)  
This bit is reserved in unmanaged mode.  
In managed mode, the CPU writes this bit with ‘1’ to indicate initialization is  
completed and ready to forward packets. The ‘0' to '1' transition will toggle  
TSTOUT[2] from low to high.  
Bits [7:5]:  
Reserved  
123  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.11.2 DCR - Device Status and Signature Register  
CPU Address: h0F01  
Accessed by CPU (RO)  
Bit [0]:  
1: Busy writing configuration to I²C  
0: Not busy (not writing configuration to I²C)  
Bit [1]:  
1: Busy reading configuration from I²C  
0: Not busy (not reading configuration from I²C)  
Bit [2]:  
1: BIST in progress  
0: BIST not running  
Bit [3]:  
1: RAM Error  
0: RAM OK  
Bits [5:4]:  
Bits [7:6]:  
Device Signature  
10: ZL50409 device  
Revision  
00: Initial Silicon  
01: Second Silicon  
12.3.11.3 DCR1 - Device Status Register 1  
CPU Address: h0F02  
Accessed by CPU (RO)  
Bits [6:0]  
Bit [7]  
Reserved  
Chip initialization completed  
12.3.11.4 DPST – Device Port Status Register  
CPU Address: h0F03  
Accessed by CPU (R/W)  
Bits [4:0]:  
Read back index register. This is used for selecting what to read back from  
DTST. (Default 00)  
-
-
-
-
-
-
-
-
-
-
5’b00000 - Port 0 Operating mode and Negotiation status  
5’b00001 - Port 1 Operating mode and Negotiation status  
5’b00010 - Port 2 Operating mode and Negotiation status  
5’b00011 - Port 3 Operating mode and Negotiation status  
5’b00100 - Port 4 Operating mode and Negotiation status  
5’b00101 - Port 5 Operating mode and Negotiation status  
5’b00110 - Port 6 Operating mode and Negotiation status  
5’b00111 - Port 7 Operating mode and Negotiation status  
5’b01000 - Port CPU Operating mode and Negotiation status  
5’b01001 - Port MMAC Operating mode and Negotiation status  
Bits [7:5]:  
Reserved  
124  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
12.3.11.5 DTST – Data read back register  
CPU Address: h0F04  
Accessed by CPU (RO)  
This register provides various internal information as selected in DPST bit [4:0]. Refer to the PHY Port Control  
Application Note, ZLAN-37.  
Bit [0]  
Flow control enable  
1: Flow control  
0: No flow control  
Bit [1]  
Full duplex port  
1: Full duplex  
0: Half duplex  
Bit [2]  
Bit [3]  
Fast Ethernet port  
1: FE Port  
Link is down  
1: Link down  
0: Link up  
Bit [4]  
Auto negotiation disabled  
1: Disable  
0: Enable  
Bit [5]  
Bit [6]  
Bit [7]  
Reserved  
Reserved  
Module detected (for hot swap purpose)  
0: No module  
1: Module detected  
Note: If Module Detect feature is disabled (bootstrap TSTOUT[9]=’0’), this bit  
will always be ‘1’.  
12.3.11.6 DA – Dead or Alive Register  
CPU Address: h0FFF  
Accessed by CPU (RO)  
Always return 8’h DA. Indicate the CPU interface or serial port connection is good.  
Bits [7:0]  
Always return DA  
125  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.0 Characteristics and Timing  
13.1 Absolute Maximum Ratings  
Storage Temperature  
-65°C to +150°C  
-40°C to +85°C  
Operating Temperature  
Maximum Junction Temperature  
Supply Voltage VCC with Respect to VSS  
Supply Voltage VDD with Respect to VSS  
Voltage on 5 V Tolerant Input Pins  
Voltage on Other Pins  
+125°C  
+2.95 V to +3.65 V  
+1.60 V to +2.00 V  
-0.5 V to (VCC + 2.5 V)  
-0.5 V to (VDD + 0.3 V)  
Caution: Stress above those listed may damage the device. Exposure to the Absolute Maximum Ratings for  
extended periods may affect device reliability. Functionality at or above these limits is not implied.  
13.2 DC Electrical Characteristics  
VCC = 3.3 V +/- 10%  
TAMBIENT = -40 C to +85 C  
VDD = 1.8 V +/- 5%  
126  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.3 Recommended Operating Conditions  
Symbol  
Parameter Description  
Min.  
Typ.1  
Max.  
Unit  
Notes  
fosc  
ICC  
Frequency of Operation (SCLK)  
50  
50  
45  
100  
60  
MHz  
mA  
mA  
mA  
mA  
W
VCC (3.3V) Supply Current @ SCLK = 100MHz  
@ SCLK = 50MHz  
35  
50  
IDD  
VDD (1.8V) Supply Current @ SCLK = 100MHz  
@ SCLK = 50MHz  
225  
140  
0.55  
0.37  
290  
180  
0.72  
0.49  
Pwr  
Power @ SCLK = 100MHz  
@ SCLK = 50MHz  
W
VOH  
VOL  
VIH  
Output High Voltage (CMOS)  
Output Low Voltage (CMOS)  
Input High Voltage  
2.4  
2.0  
V
0.4  
V
VCC  
2.0  
+
V
(TTL 5V  
tolerant  
inputs)  
VIL  
IIL  
Input Low Voltage  
0.8  
10  
V
Input Leakage Current (0.1 V < VIN < VCC  
(all pins except those with internal  
pull-up/pull-down resistors)  
)
µA  
IOL  
Output Leakage Current (0.1 V < VOUT < VCC  
Input Capacitance  
)
10  
5
µA  
pF  
CIN  
COUT  
CI/O  
θja  
Output Capacitance  
5
pF  
I/O Capacitance  
7
pF  
Thermal resistance with 0 air flow  
Thermal resistance with 1 m/s air flow  
Thermal resistance with 2 m/s air flow  
24.3  
20.0  
18.1  
4.6  
C/W  
C/W  
C/W  
C/W  
C/W  
No Heat Sink  
θjc  
Thermal resistance between junction and case  
θja-min  
Min. required thermal resistance ((TJ-TA) / Pwr)  
@ SCLK = 100MHz  
55  
No Heat Sink  
Req’d  
@ SCLK = 50MHz  
108  
C/W  
1. Assuming full line-rate switching  
127  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4 AC Characteristics and Timing  
13.4.1 Typical Reset & Bootstrap Timing Diagram  
RESIN#  
RESETOUT#  
Tri-Stated  
R1  
R3  
Bootstrap Pins  
Outputs  
Inputs  
Outputs  
R2  
Figure 14 - Typical Reset & Bootstrap Timing Diagram  
Symbol  
Parameter  
Min.  
Typ.  
Refer to Figure 14  
R1  
Delay until RESETOUT# is tri-stated  
10 ns RESETOUT# state is then determined by  
the external pull-up/down resistor  
R2  
R3  
Bootstrap stabilization  
1 µs  
10 µs Bootstrap pins sampled on rising edge of  
RESIN#  
RESETOUT# assertion  
2 ms  
Table 13 - Reset Timing  
128  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.2 Typical CPU Timing Diagram for a CPU Write Cycle  
ADDR0  
ADDR1  
P_A[2:0]  
P_CS#  
TWH  
TWH  
TWS  
TWS  
TWA  
Activ eTime  
TWR  
TWA  
Activ eTime  
Recov ery Time  
P_WE#  
TDH  
TDH  
TDS  
TDS  
P_DATA  
(todev ice)  
DATA0  
DATA1  
Set uptime  
Holdtime  
Figure 15 - Typical CPU Timing Diagram for a CPU Write Cycle  
Description  
(SCLK=100 Mhz) (SCLK=50 Mhz)  
Refer to Figure 15  
Min.  
(ns)  
Max.  
(ns)  
Min.  
(ns)  
Max.  
(ns)  
Write Cycle  
Symbol  
Write Set up Time  
TWS  
10  
10  
P_A and P_CS# to falling  
edge of P_WE#  
Write Active Time  
Write Hold Time  
TWA  
TWH  
20  
2
40  
2
At least 2 SCLK cycles  
P_A and P_CS# to rising  
edge of P_WE#  
Write Recovery time  
Data Set Up time  
TWR  
TDS  
30  
10  
60  
10  
At least 3 SCLK cycles  
P_DATA to falling edge of  
P_WE#  
Data Hold time  
TDH  
2
2
P_DATA to rising edge of  
P_WE#  
Table 14 - CPU Write Timing  
129  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.3 Typical CPU Timing Diagram for a CPU Read Cycle  
ADDR0  
ADDR1  
P_A[2:0]  
TRH  
TRH  
TRS  
TRS  
P_CS#  
TRA  
TRR  
TRA  
Activ eTime  
Activ eTime  
Recov ery Time  
P_RD#  
TDI  
TDI  
TDV  
TDV  
P_DATA  
(toCPU)  
DATA0  
DATA1  
Valid time  
Inv alidtime  
Figure 16 - Typical CPU Timing Diagram for a CPU Read Cycle  
Description  
Read Cycle  
(SCLK=100 Mhz)  
(SCLK=50 Mhz)  
Refer to Figure 16  
Min.  
(ns)  
Max.  
(ns)  
Min.  
(ns)  
Max.  
(ns)  
Symbol  
Read Set up Time  
TRS  
10  
10  
P_A and P_CS# to falling  
edge of P_RD#  
Read Active Time  
Read Hold Time  
TRA  
TRH  
20  
2
40  
2
At least 2 SCLK cycles  
P_A and P_CS# to rising  
edge of P_RD#  
Read Recovery time  
Data Valid time  
TRR  
TDV  
30  
60  
At least 3 SCLK cycles  
12  
10  
12  
10  
P_DATA to falling edge of  
P_RD#  
Data Invalid time  
TDI  
P_DATA to rising edge of  
P_RD#  
Table 15 - CPU Read Timing  
130  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.4 Synchronous Serial Interface (SSI)  
STROBE  
D4  
D5  
D2  
D2  
D1  
D1  
Datain  
Figure 17 - SSI Setup & Hold Timing  
STROBE  
D3-max  
D3-min  
Dataout  
Figure 18 - SSI Output Delay Timing  
Symbol  
Parameter  
Min. (ns) Max. (ns)  
Notes  
D1  
D2  
DATAIN setup time  
DATAIN hold time  
20  
3 µs  
20  
Debounce on  
Debounce off  
D3*  
D3**  
D4  
DATAOUT output delay time  
Debounce on  
CL = 100 pf  
1
50  
Debounce off  
CL = 100 pf  
STROBE low time  
5 µs  
50  
Debounce on  
Debounce off  
Debounce on  
Debounce off  
Debounce on  
Debounce off  
D5  
STROBE high time  
5 µs  
50  
STROBE frequency of operation  
100 kHz  
10 MHz  
* Open Drain Output. Low to High transition is controlled by external pullup resistor.  
** Totem Pole Output.  
131  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.5 EEPROM Inter-Integrated Circuit (I²C)  
SCL  
S2  
S1  
SDA  
Figure 19 - I²C Setup & Hold Timing  
SCL  
S3-max  
S3-min  
SDA  
Figure 20 - I²C Output Delay Timing  
SCL=50 KHz  
Symbol  
Parameter  
SDA input setup time  
Notes  
Min. (ns) Max. (ns)  
S1  
S2  
20  
1
SDA input hold time  
S3*  
SDA output delay time  
4 µs  
6 µs  
CL = 30 pf  
* Open Drain Output. Low to High transition is controlled by external pullup resistor.  
132  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.6 Reduced Media Independent Interface (RMII)  
M_CLK  
M6-max  
M6-min  
Mn_TXEN  
M7-max  
M7-min  
Mn_TXD[1:0]  
Figure 21 - RMII Transmit Timing  
M_CLK  
M2  
Mn_RXD  
M3  
M4  
Mn_CRS_DV  
M5  
Figure 22 - RMII Receive Timing  
M_CLK=50 MHz  
Symbol  
Parameter  
Notes  
Min. (ns)  
Max. (ns)  
M2  
M3  
M4  
M5  
M6  
M7  
M[7:0]_RXD[1:0] Input Setup Time  
M[7:0]_RXD[1:0] Input Hold Time  
M[7:0]_CRS_DV Input Setup Time  
M[7:0]_CRS_DV Input Hold Time  
M[7:0]_TXEN Output Delay Time  
M[7:0]_TXD[1:0] Output Delay Time  
4
2
4
3
2
2
11  
11  
CL = 20 pF  
CL = 20 pF  
133  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.7 Media Independent Interface (MII)  
Mn_TXCLK  
Mn_TXEN  
MM6-max  
MM6-min  
MM7-max  
MM7-min  
Mn _TXD[3:0]  
Figure 23 - MII Transmit Timing  
Mn_RXCLK  
MM2  
MM4  
Mn_RXD[3:0]  
Mn_CRS_DV  
MM  
3
MM  
5
Figure 24 - MII Receive Timing  
25 MHz  
Symbol  
Parameter  
Notes  
Min. (ns)  
Max. (ns)  
MM2  
MM3  
MM4  
MM5  
MM6  
MM7  
Mn_RXD[3:0] Input Setup Time  
Mn_RXD[3:0] Input Hold Time  
Mn_CRS_DV Input Setup Time  
Mn_CRS_DV Input Hold Time  
Mn_TXEN Output Delay Time  
Mn_TXD[3:0] Output Delay Time  
4
2
4
2
2
2
14  
14  
CL = 20 pF  
CL = 20 pF  
134  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.8 Reverse Media Independent Interface (RvMII)  
Mn_TXCLK  
RM6-max  
RM6-min  
Mn_TXEN  
RM7-max  
RM7-min  
Mn _TXD[3:0]  
Figure 25 - RvMII Transmit Timing  
Mn_RXCLK  
RM2  
RM4  
Mn_RXD[3:0]  
Mn_CRS_DV  
RM3  
RM5  
Figure 26 - RvMII Receive Timing  
25 MHz  
Symbol  
Parameter  
Notes  
Min. (ns)  
Max. (ns)  
RM2  
Mn_RXD[3:0] Input Setup Time  
CPU_MII_RXD[3:0] Input Setup Time  
Mn_RXD[3:0] Input Hold Time  
4
10  
2
RM3  
RM4  
RM5  
RM6*  
RM7*  
CPU_MII_RXD[3:0] Input Hold Time  
Mn_CRS_DV Input Setup Time  
CPU_MII_CRS_DV Input Setup Time  
Mn_CRS_DV Input Hold Time  
4
10  
2
CPU_MII_CRS_DV Input Hold Time  
Mn_TXEN Output Delay Time  
2
0
2
0
14  
5
CL = 20 pF  
CPU_MII_TXEN Output Delay Time  
Mn_TXD[3:0] Output Delay Time  
CPU_MII_TXD[3:0] Output Delay Time  
14  
5
CL = 20 pF  
* May need to add external delay depending on other MAC device’s min. hold time.  
135  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.9 General Purpose Serial Interface (GPSI)  
Mn_TXCLK  
Mn_TXEN  
SM6-max  
SM6-min  
SM7-max  
SM7-min  
Mn_TXD  
Figure 27 - GPSI Transmit Timing  
Mn_RXCLK  
SM2  
SM4  
Mn_RXD  
SM3  
SM5  
Mn_CRS_DV  
Figure 28 - GPSI Receive Timing  
10 MHz  
Symbol  
Parameter  
Notes  
Min. (ns)  
Max. (ns)  
SM2  
SM3  
SM4  
SM5  
SM6  
SM7  
M[7:0]_RXD Input Setup Time  
M[7:0]_RXD Input Hold Time  
4
2
4
2
2
2
M[7:0]_CRS_DV Input Setup Time  
M[7:0]_CRS_DV Input Hold Time  
M[7:0]_TXEN Output Delay Time  
M[7:0]_TXD Output Delay Time  
14  
14  
CL = 20 pF  
CL = 20 pF  
136  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.10 Reverse General Purpose Serial Interface (RvGPSI)  
Mn_TXCLK  
RS6-max  
RS6-min  
Mn_TXEN  
RS7-max  
RS7-min  
Mn_TXD  
Figure 29 - RvGPSI Transmit Timing  
Mn_RXCLK  
RS2  
Mn_RXD  
RS3  
RS4  
Mn_CRS_DV  
RS5  
Figure 30 - RvGPSI Receive Timing  
10 MHz  
Symbol  
Parameter  
Notes  
Min. (ns)  
Max. (ns)  
RS2  
RS3  
RS4  
RS5  
RS6*  
RS7*  
M[7:0]_RXD Input Setup Time  
M[7:0]_RXD Input Hold Time  
4
2
4
2
2
2
M[7:0]_CRS_DV Input Setup Time  
M[7:0]_CRS_DV Input Hold Time  
M[7:0]_TXEN Output Delay Time  
M[7:0]_TXD Output Delay Time  
14  
14  
CL = 20 pF  
CL = 20 pF  
* May need to add external delay depending on other MAC device’s min. hold time.  
137  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.11 MII Management Data Interface (MDIO/MDC)  
MDC  
MD1  
MD2  
MDIO  
Figure 31 - MDIO Setup & Hold Timing  
MDC  
MD3-max  
MD3-min  
MDIO  
Figure 32 - MDIO Output Delay Timing  
MDC=500 KHz  
Parameter  
Symbol  
Notes  
Min. (ns) Max. (ns)  
MD1  
MDIO input setup time  
10  
MD2  
MD3  
MDIO input hold time  
0
1
MDIO output delay time  
20  
CL = 50 pf  
138  
Zarlink Semiconductor Inc.  
ZL50409  
Data Sheet  
13.4.12 JTAG (IEEE 1149.1-2001)  
TCK  
TMS, TDI  
J1  
J2  
J3-max  
TDO  
J3-min  
Figure 33 - JTAG Timing Diagram  
Symbol  
Parameter  
Min.  
Typ.  
Max.  
Units  
Refer to Figure 33  
TCK frequency of operation  
TCK cycle time  
0
10  
50  
MHz  
ns  
20  
10  
20  
TCK clock pulse width  
TRST# assert time  
ns  
-
ns  
TRST is an  
asynchronous signal  
J1  
J2  
J3  
TMS, TDI data setup time  
TMS, TDI data hold time  
TCK to TDO data valid  
3
7
0
ns  
ns  
ns  
15  
139  
Zarlink Semiconductor Inc.  
BOTTOM VIEW  
TOP VIEW  
MIN  
0.30  
MAX  
1.40  
0.50  
Dimension  
A
A1  
A2  
D
E
b
0.53 REF  
16.90  
16.90  
0.40  
17.10  
17.10  
0.60  
1.00  
208  
e
N
Conforms to JEDEC MO-192  
b
SIDE VIEW  
Package Code  
c
Zarlink Semiconductor 2002 All rights reserved.  
Previous package codes  
1
ISSUE  
ACN  
213730  
14Nov02  
DATE  
APPRD.  
For more information about all Zarlink products  
visit our Web Site at  
www.zarlink.com  
Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable.  
However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such  
information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or  
use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual  
property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in  
certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink.  
This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part  
of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other  
information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the  
capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute  
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and  
suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does  
not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in  
significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request.  
Purchase of Zarlink’s I2C components conveys a licence under the Philips I2C Patent rights to use these components in and I2C System, provided that the system  
conforms to the I2C Standard Specification as defined by Philips.  
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.  
Copyright Zarlink Semiconductor Inc. All Rights Reserved.  
TECHNICAL DOCUMENTATION - NOT FOR RESALE  

相关型号:

ZL50409GDG2

DATACOM, LAN SWITCHING CIRCUIT, PBGA208, 17 X 17 MM, 1.40 MM HEIGHT, LEAD FREE, MO-192, LBGA-208
MICROSEMI

ZL50410

Managed 8-Port 10/100M + 1-Port 10/100/1000M Ethernet Switch
ZARLINK

ZL50410GDC

LAN Switching Circuit, PBGA208, 17 X 17 MM, 1.40 MM HEIGHT, MO-192, LBGA-208
MICROSEMI

ZL50410GDC

LAN Switching Circuit, PBGA208, 17 X 17 MM, 1.40 MM HEIGHT, MO-192, LBGA-208
ZARLINK

ZL50410GDC208

Managed 8-Port 10/100M + 1-Port 10/100/1000M Ethernet Switch
ZARLINK

ZL50410GDG

Interface Circuit, PBGA208, 17 X 17 MM, 1.40 MM HEIGHT, MO-192, LBGA-208
ZARLINK

ZL50410GDG2

LAN Switching Circuit, PBGA208, 17 X 17 MM, 1.40 MM HEIGHT, LEAD FREE, MO-192, LBGA-208
ZARLINK

ZL50411GDC

LAN Switching Circuit, PBGA208, 17 X 17 MM, 1.40 MM HEIGHT, MO-192, LBGA-208
ZARLINK

ZL50415

Managed 16-Port 10/100 M + 2-Port 1 G Ethernet Switch
ZARLINK

ZL50415/GKC

DATACOM, LAN SWITCHING CIRCUIT, PBGA553, 37.50 X 37.50 MM, 2.33 MM HEIGHT, MS-034, HSBGA-553
MICROSEMI

ZL50415GKG

LAN Switching Circuit, PBGA553, 37.50 X 37.50 MM, 2.33 MM HEIGHT, MS-034, HSBGA-553
MICROSEMI

ZL50415GKG2

DATACOM, LAN SWITCHING CIRCUIT, PBGA553, 37.50 X 37.50 MM, 2.33 MM HEIGHT, LEAD FREE, MS-034, HSBGA-553
MICROSEMI