MDWI03 SERIES  
DC/DC CONVERTER 3W, DIP Package  
FEATURES  
Ultra compact DIP Package  
23.8 x 13.7 x 8.0 mm (0.94 x 0.54 x 0.31 inches)  
Efficiency up to 80%  
I/O-isolation 1500VDC  
Ultra-wide 4:1 Input Range  
Operating Temp. Range -40°C to +85°C  
Remote On/Off Control  
Input Filter meets EN 55022,class A and FCC, level A  
CSA/UL/IEC/EN 60950-1 Safety Approval  
3 Years Product Warranty  
PRODUCT OVERVIEW  
Minmax's MDWI03 series power modules are in mini-DIP DC/DC converters that operate over input voltage ranges of 9-36VDC and 18-75VDC which  
provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, 24V, ±5V, ±12V and ±15VDC.  
Pin compatible with the MDW1000 series, the MDWI03 offers a power rating up to 3W and a typical full-load efficiency of 80%, continuous short circuit,  
remote on/off control, EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering.  
The MDWI03 series is an excellent selection for data communication equipment, mobile battery driven equipment, distributed power system,  
telecommunication equipment, mixed analog/digital subsystem, process/machine control equipment, computer peripheral equipment and industrial robot  
system.  
Model Selection Guide  
Model  
Input  
Voltage  
(Range)  
VDC  
Output  
Output  
Input Current  
Max. capacitive  
Load  
Efficiency  
(typ.)  
Number  
Voltage  
Current  
@Max. Load  
@No Load  
mA(typ.)  
Max.  
Min.  
@Max. Load  
VDC  
3.3  
5
12  
15  
mA  
600  
600  
250  
200  
mA  
90  
90  
38  
30  
mA(typ.)  
110  
160  
156  
156  
156  
162  
156  
156  
55  
μF  
220  
220  
47  
47  
47  
47#  
47#  
47#  
220  
220  
47  
47  
47  
47#  
47#  
47#  
%
75  
78  
80  
80  
80  
77  
80  
80  
75  
78  
80  
80  
80  
77  
80  
80  
MDWI03-24S033  
MDWI03-24S05  
MDWI03-24S12  
MDWI03-24S15  
MDWI03-24S24  
MDWI03-24D05  
MDWI03-24D12  
MDWI03-24D15  
MDWI03-48S033  
MDWI03-48S05  
MDWI03-48S12  
MDWI03-48S15  
MDWI03-48S24  
MDWI03-48D05  
MDWI03-48D12  
MDWI03-48D15  
24  
(9 ~ 36)  
30  
24  
125  
19  
±5  
±12  
±15  
3.3  
5
12  
15  
24  
±300  
±125  
±100  
600  
600  
250  
200  
125  
±300  
±125  
±100  
±45  
±19  
±15  
90  
90  
38  
30  
19  
±45  
±19  
±15  
80  
78  
78  
78  
81  
78  
78  
48  
(18 ~ 75)  
20  
±5  
±12  
±15  
# For each output  
Input Specifications  
Parameter  
Model  
Min.  
-0.7  
-0.7  
4.5  
8.5  
---  
Typ.  
Max.  
50  
Unit  
VDC  
mW  
24V Input Models  
48V Input Models  
24V Input Models  
48V Input Models  
24V Input Models  
48V Input Models  
---  
---  
6
Input Surge Voltage (1 sec. max.)  
Start-Up Threshold Voltage  
Under Voltage Shutdown  
100  
8.5  
17  
12  
---  
---  
---  
8
---  
16  
Short Circuit Input Power  
Conducted EMI  
---  
2000  
All Models  
Compliance to EN 55022,class A and FCC part 15,class A  
E-mail:sales@minmax.com.tw  
Tel:886-6-2923150  
2012/07/16 REV:17  
Page 1 of 4  
®
MDWI03 SERIES  
DC/DC CONVERTER 3W, DIP Package  
Output Specifications  
Parameter  
Conditions  
Min.  
---  
Typ.  
---  
Max.  
±2.0  
±2.0  
±1.0  
±1.2  
100  
Unit  
%Vom.  
%
Output Voltage Setting Accuracy  
Output Voltage Balance  
Line Regulation  
At 50% Load and Nominal Vin  
Dual Output, Balanced Loads  
Vin=Min. to Max.  
---  
±1.0  
±0.5  
±0.5  
50  
---  
%
Load Regulation  
Io=15% to 100%  
---  
%
Ripple & Noise (20MHz)  
Transient Recovery Time  
Transient Response Deviation  
Temperature Coefficient  
Over Load Protection  
Short Circuit Protection  
---  
mV P-P  
μsec  
%
---  
300  
±3  
600  
25% Load Step Change  
Foldback  
---  
---  
---  
±0.01  
150  
±0.02  
---  
%/  
%
110  
Continuous  
General Specifications  
Parameter  
I/O Isolation Voltage (rated)  
I/O Isolation Resistance  
I/O Isolation Capacitance  
Switching Frequency  
Conditions  
60 Seconds  
500 VDC  
Min.  
1500  
1000  
---  
Typ.  
---  
Max.  
---  
Unit  
VDC  
MΩ  
---  
---  
100KHz, 1V  
350  
350  
---  
500  
---  
pF  
---  
KHz  
Hours  
MTBF (calculated)  
MIL-HDBK-217F@25, Ground Benign  
300,000  
---  
Safety Approvals  
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme)  
Input Fuse  
24V Input Models  
48V Input Models  
1500mA Slow-Blow Type  
800mA Slow-Blow Type  
Remote On/Off Control  
Parameter  
Conditions  
Min.  
Typ.  
Max.  
Unit  
Converter On  
Converter Off  
2.5V ~ 5.5V or Open Circuit  
-0.7V ~ 0.8V  
Control Input Current (on)  
Control Input Current (off)  
Control Common  
Vctrl = Min. to Max.  
Vctrl = Min. to Max.  
---  
---  
-400  
μA  
μA  
---  
---  
-400  
Referenced to Negative Input  
---  
Standby Input Current  
---  
5
mA  
Environmental Specifications  
Parameter  
Conditions  
Natural Convection  
Min.  
Max.  
+85  
Unit  
% rel. H  
Operating Ambient Temperature Range (See Power Derating Curve)  
Case Temperature  
-40  
---  
+105  
+125  
95  
Storage Temperature Range  
-50  
---  
Humidity (non condensing)  
Cooling  
Free-Air convection  
---  
Lead Temperature (1.5mm from case for 10Sec.)  
260  
E-mail:sales@minmax.com.tw  
Tel:886-6-2923150  
2012/07/16 REV:17  
Page 2 of 4  
®
MDWI03 SERIES  
DC/DC CONVERTER 3W, DIP Package  
Power Derating Curve  
Notes  
1
2
3
4
Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.  
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%  
Ripple & Noise measurement bandwidth is 0-20MHz.  
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules;  
however, they may not meet all specifications listed.  
5
6
7
8
All DC/DC converters should be externally fused at the front end for protection.  
Other input and output voltage may be available, please contact factory.  
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).  
Specifications are subject to change without notice.  
Package Specifications  
Mechanical Dimensions  
Pin Connections  
Pin  
Single Output  
-Vin  
Dual Output  
-Vin  
23.8 [0.94]  
1
2
7
Remote On/Off  
Remote On/Off  
NC  
NC  
NC  
8
Common  
+Vout  
9
+Vout  
-Vout  
+Vin  
10  
16  
-Vout  
+Vin  
[0.02]  
0.5  
0.5 [0.02]  
NC: No Connection  
2.54  
3.0  
12.7  
2.54  
[0.10]  
[0.10]  
[0.12]  
[0.50]  
1
2
7
8
Bottom View  
16  
10  
9
All dimensions in mm (inches)  
Tolerance: X.X±0.25 (X.XX±0.01)  
15.24 [0.60]  
23.8 [0.94]  
2.54  
[0.10]  
X.XX±0.13 ( X.XXX±0.005)  
Pin diameter 0.5 ±0.05 (0.02±0.002)  
Physical Characteristics  
Case Size  
Case Material  
Pin Material  
Weight  
:
:
:
:
23.8x13.7x8.0 mm (0.94x0.54x0.31 inches)  
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)  
phosphor bronze  
5.4g  
E-mail:sales@minmax.com.tw  
Tel:886-6-2923150  
2012/07/16 REV:17  
Page 3 of 4  
®
MDWI03 SERIES  
DC/DC CONVERTER 3W, DIP Package  
Test Setup  
Input Reflected-Ripple Current Test Setup  
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0at 100 KHz) to simulate source impedance. Capacitor Cin, offsets  
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.  
To Oscilloscope  
+Vin  
+Out  
+
+
Lin  
DC / DC  
Converter  
Current  
Probe  
Load  
Battery  
Cin  
-Vin  
-Out  
Peak-to-Peak Output Noise Measurement Test  
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load  
between 50 mm and 75 mm from the DC/DC Converter.  
Copper Strip  
Cout  
+Vin  
+Out  
Copper Strip  
+Vin  
+Out  
Com.  
-Out  
Scope  
Scope  
Single Output  
DC / DC  
Converter  
Dual Output  
DC / DC  
Converter  
Resistive  
Load  
Resistive  
Load  
Cout  
Scope  
Copper Strip  
Cout  
-Vin  
-Out  
Copper Strip  
-Vin  
Copper Strip  
Technical Notes  
Remote On/Off  
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,  
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.  
A logic low is -0.7V to 0.8V. A logic high is 2.5V to 5.5V. The maximum sink current of the switch at on/off terminal during a logic low is -300 μA.  
The maximum sink current of the switch at on/off terminal during a logic high is -200μA or open.  
Overcurrent Protection  
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited  
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back  
into its specified range.  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.  
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.  
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR <  
1.0at 100 KHz) capacitor of a 4.7μF for the 24V input devices and a 2.2μF for the 48V devices.  
+
+Vin  
+Out  
+
DC / DC  
Converter  
DC Power  
Source  
Load  
Cin  
-
-Vin  
-Out  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is  
recommended to use 3.3μF capacitors at the output.  
+
+Vin  
-Vin  
+Out  
+
+Vin  
-Vin  
+Out  
Com.  
-Out  
Single Output  
DC / DC  
Converter  
Load  
Load  
Dual Output  
DC / DC  
Converter  
DC Power  
Source  
Cout  
Cout  
DC Power  
Source  
Cout  
Load  
-
-Out  
-
Maximum Capacitive Load  
The MDWI03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,  
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the  
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105. The derating curves are determined  
from measurements obtained in a test setup.  
Position of air velocity  
probe and thermocouple  
Air Flow  
50mm / 2in  
15mm / 0.6in  
DUT  
Minmax Technology Co., Ltd.  
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan  
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: sales@minmax.com.tw  
2012/07/16 REV:17 Page 4 of 4  

相关型号:

MDWI06

DC-DC CONVERTER 6W
MINMAX

MDWI06-24D12

DC-DC CONVERTER 6W
MINMAX

MDWI06-24D15

DC-DC CONVERTER 6W
MINMAX

MDWI06-24S033

DC-DC CONVERTER 6W
MINMAX

MDWI06-24S05

DC-DC CONVERTER 6W
MINMAX

MDWI06-24S12

DC-DC CONVERTER 6W
MINMAX

MDWI06-24S15

DC-DC CONVERTER 6W
MINMAX

MDWI06-24S24

DC-DC CONVERTER 6W
MINMAX

MDWI06-48D12

DC-DC CONVERTER 6W
MINMAX

MDWI06-48D15

DC-DC CONVERTER 6W
MINMAX

MDWI06-48S033

DC-DC CONVERTER 6W
MINMAX

MDWI06-48S05

DC-DC CONVERTER 6W
MINMAX