DRL-DPM-PCIE [MOLEX]

Direct-Link PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x; 直接链接PCU - DPIO PROFIBUS- DP主/从12 Mbps时, PCI Express的1X
DRL-DPM-PCIE
型号: DRL-DPM-PCIE
厂家: Molex    Molex
描述:

Direct-Link PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x
直接链接PCU - DPIO PROFIBUS- DP主/从12 Mbps时, PCI Express的1X

PC
文件: 总6页 (文件大小:1325K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
This document was generated on 05/18/2010  
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION  
Part Number:  
Status:  
1120115028  
Active  
EU RoHS  
ELV and RoHS  
Compliant  
China RoHS  
Description:  
Direct-Link™ PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x  
REACH SVHC  
Not Reviewed  
Halogen-Free  
Status  
Documents:  
Drawing (PDF)  
RoHS Certificate of Compliance (PDF)  
Not Reviewed  
Need more information on product  
environmental compliance?  
General  
Product Family  
Series  
Network Interface  
112011  
Approvals  
Comments  
CE  
Email productcompliance@molex.com  
For a multiple part number RoHS Certificate of  
Compliance, click here  
Profibus DP-V0 (Master & Slave). . PROFIBUS DP-V1  
(Master)  
Profibus: 9.6 kbps to 12 Mbps  
N/A  
Communication Speed  
MAC Address  
Mounting Style  
Product Name  
Protocol  
Please visit the Contact Us section for any  
non-product compliance questions.  
N/A  
Direct-Link®  
Profibus* DP  
Profibus* Card  
Type  
Search Parts in this Series  
112011Series  
Physical  
Channels  
1
Interface  
Profibus*  
Network Connection Type  
Packaging Type  
Processor  
D-Sub Female (9 pin)  
Individual Carton  
AMD SC520  
0°C to +65°C  
Temperature Range - Operating  
Electrical  
Current - Maximum Input  
EMC  
5.5W  
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, IEC  
61000-6-2  
3.3V  
Supply Voltage  
Material Info  
Old Part Number  
DRL-DPM-PCIE  
SD-112011-0008  
Reference - Drawing Numbers  
Sales Drawing  
This document was generated on 05/18/2010  
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION  
BradCommunications™ Direct-LinkProfibus-DP network  
interface cards allow deterministic I/O data acquisition  
for PC-based control applications.  
27 Jan. 10  
DW200591  
Direct-Link™ Profibus-DP  
Data acquisition for real time Control applications  
Features  
NEW! RoHS compliant  
Connect PC-Based Control  
applications directly to I/O  
devices  
PCI-Universal  
PC/104  
Protocols supported:  
ƒ Profibus-DP V0 Master/Slave  
Class-1 & 2  
PCI Express  
ƒ Profibus-DP V1 Master Class-1 &  
2 (for PCI-Universal card only)  
ƒ
Profibus-DP Slave passive  
Available in various card form  
factor: PC/104, PCI-Universal and  
CompactPCI 3U  
CompactPCI  
Overview  
1 Serial or Ethernet port for  
remote configuration  
and diagnostic  
BradCommunications™ Direct-Link™ is a low range of automation components for  
industrial communication. It includes a variety of products such as diagnostic tools,  
intelligent connectors, tunneling gateways, fieldbuses network interface cards, and  
software drivers for industrial networks.  
Automatic devices detection on  
the network  
Simple as they are affordable, BradCommunications™ Direct-Link™ products allow  
you to acquire the equipment to develop your architectures and industrial  
applications at a lower cost.  
Embedded Communication on  
the card for powerful data  
throughput  
Direct-Link™ products are characterized by their simple use and fast  
implementation; they are modular and scalable. Moreover, they are designed to be  
easily embedded into computerized systems and are available in a wide selection  
of form factors.  
Configuration stored in the device  
(Flash memory), with auto boot  
mode  
Powerful Network Interface card  
Particularly, the BradCommunications™ Direct-Link™ Profibus-DP interface  
cards are equipped with 1 Profibus port handling Profibus protocol in Master  
and/or Slave modes up to 12 Mbps.  
OS supported  
Standard package  
Windows 32-bit (XP SP1/ 2000 SP4 /  
NT SP6, 2003 Server), Ardence  
RTX  
A smart A.D.M (Automatic Dual port ram Mapping) mechanism avoids the I/O tags  
configuration in the Dual Port RAM of the card. More than a simple I/O acquisition  
card, the Direct-Link™ interface cards provide the applications with additional  
information such as: device status and diagnostics, process data read/write  
monitoring, communication tools for troubleshooting, hardware and software  
Watchdog, etc..  
Free Download  
Windows XP Embedded, QNX,  
VxWorks, Linux, Phar Lap ETS,  
DOS  
The communication layers are completely embedded on the cards, allowing easy  
and fast communication with field devices resulting in remarkable application  
performance.  
Woodhead is a member of PTO (PROFIBUS  
Trade Organization), PNO (PROFIBUS  
Nutzerorganisation e. V.) and France  
Profibus.  
Product package includes:  
ƒ
ƒ
Graphical console for configuration and diagnostic tools  
Data servers (Multi-protocol OPC DA 3.0 & 2.05, ActiveX, DAServer,  
FastDDE/SuiteLink)  
ƒ
I/O libraries for Windows (DLL) and Ardence's hard real time extensions  
(RTX)  
ƒ
ƒ
Static library for non-windows OS  
Drivers for soft-logic packages  
Technical data  
Direct-Link™  
PCU-DPIO  
Direct-Link™  
PCIE-DPIO  
Key Benefits  
Fast data exchange (on-board processor take off the load of the host CPU)  
Speed up to 12 Mbps  
Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS  
DP-V0 Master Class 1 & 2/Slave simultaneously  
DP-V1 Master Class 1 & 2  
Hardware  
PCI-Universal 3.3/5V, PCI-X compatible  
AMD SC520, 133 Mhz  
PCI Express 1x  
Unit  
AMD SC520, 133 Mhz  
UART High Speed  
Processor  
Profibus ASIC  
UART High Speed  
16 Mbytes SDRAM  
4 Mbytes  
16 Mbytes SDRAM  
4 Mbytes  
Memory  
Flash Memory  
Interruption  
Hardware Plug&Play  
Hardware Plug&Play  
Hardware Plug&Play (32 Kbytes)  
Hardware Plug&Play (32 Kbytes)  
DPRAM Address  
Discrete Input  
1 x Opto-coupled discrete input,  
1 x Opto-coupled discrete input,  
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)  
1 x "WatchDog" output contact free from potential  
(floating) (24 V DC, 0.25 A)  
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)  
1 x "WatchDog" output contact free from potential  
(floating) (24 V DC, 0.25 A)  
Discrete Output  
168mm x 107mm (6.61" x 4.21")  
5.5W (max. 1.2A)  
168mm x 107mm (6.61" x 4.21")  
5.5W (max. 1.2A)  
Dimensions (LxW)  
Consumption  
Operating T°  
Storage T°  
0ºC (32ºF) up to +65°C (149°F)  
0ºC (32ºF) up to +65°C (149°F)  
-40º C (-40°F) up to +85ºC (185º F)  
-40º C (-40°F) up to +85ºC (185º F)  
EN55022 Class B, EN61000-6-2, EN61000-3-2,  
EN61000-3-3  
EN55022 Class B, EN61000-6-2, EN61000-3-2,  
EN61000-3-3  
EMC Compliance  
RoHS Compliance  
Communication port  
YES  
YES  
1 Profibus port (EN 50170)  
1 Profibus port (EN 50170)  
Port type  
Profibus D-Sub, 9 pin, female  
2 bicolor Leds: bus fault and communication status  
RS485 optical insulation (500 V)  
9.6 kbps 12 Mbps  
Profibus D-Sub, 9 pin, female  
2 bicolor Leds: bus fault and communication status  
RS485 optical insulation (500 V)  
9.6 kbps 12 Mbps  
Connector  
LED Indicator  
Electrical Interface  
Baud Rate  
Port for remote configuration and diagnostic  
Ethernet port  
RJ45  
Ethernet port  
RJ45  
Port Type  
Connector type  
LED indicators  
Electrical interface  
Speed  
4 Leds - TX/RX/Link/100 Mbps  
Ethernet  
4 Leds - TX/RX/Link/100 Mbps  
Ethernet  
10/100 Mbps  
10/100 Mbps  
Technical data  
Direct-Link™  
PC104-DPIO  
Direct-Link™  
CPCI-DPIO  
Key Benefits  
Fast data exchange (on-board processor take off the load of the host CPU)  
Speed up to 12 Mbps  
Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS  
DP-V0 Master Class 1 & 2/ Slave simultaneously  
Hardware  
PC/104 bus  
CompactPCI bus, 5V  
AMD SC520, 133 Mhz  
ASPC2  
Unit  
AMD SC520, 100 Mhz  
ASPC2  
Processor  
Profibus ASIC  
Memory  
8 Mbytes SDRAM  
8 Mbytes SDRAM  
512 kbytes  
512 Kbytes  
Flash Memory  
Interruption  
DPRAM Address  
2, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15  
From C8000 to DE000 (8 Kbytes used per card)  
Hardware Plug&Play  
Hardware Plug&Play (16 Kbytes)  
1 x Opto-coupled discrete input,  
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)  
1 x Opto-coupled discrete input,  
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)  
Discrete Input  
1 x "WatchDog" output contact free from potential  
(floating) (24 V DC, 0.25 A)  
1 x "WatchDog" output contact free from potential  
(floating) (24 V DC, 0.25 A)  
Discrete Output  
95mm x 90mm (3.74" x 3.54")  
5.5W (max. 1.2A)  
100mm x 160mm (3.93" x 6.29") - 3U  
5,5W (max. 1.2A)  
Dimensions (LxW)  
Consumption  
Operating T°  
Storage T°  
0ºC (32°F) up to +65ºC (149ºF)  
-40º C (-40°F) up to +85ºC (185º F)  
0º C (32º F) +65º C (149º F)  
-40º C (-40°F) up to +85ºC (185º F)  
EN55022 Class B, EN61000-6-2, EN61000-3-2,  
EN61000-3-3  
EN55022 Class B, EN61000-6-2, EN61000-3-2,  
EN61000-3-3  
EMC Compliance  
RoHS Compliance  
NO  
YES  
Communication port  
Port type  
1 Profibus port (EN 50170)  
1 Profibus port (EN 50170)  
Profibus D-Sub, 9 pin, female  
In standard: HE13 (2 x 5 pins) or in option: 9-pin, Sub-  
D, female  
Connector  
2 bicolor Leds: bus fault and communication status  
RS485 optical insulation (500 V)  
9.6 kbps 12 Mbps  
2 bicolor Leds: bus fault and communication status  
RS485 optical insulation (500 V)  
9.6 kbps 12 Mbps  
LED Indicator  
Electrical Interface  
Baud Rate  
Port for remote configuration and diagnostic  
Asynchronous Serial port  
HE13 (2 x 5 pins)  
-
Asynchronous Serial port  
9-pin, Sub-D, male  
2 Leds - TX/RX  
Port Type  
Connector type  
LED indicators  
Electrical interface  
Speed  
RS232 – 2 signals  
9600, 38400, 115200 bps  
RS232 – 2 signals  
9600, 38400, 115200 bps  
Direct-Link™ Profibus-DP  
Protocol Specifications  
All BradCommunications™ Direct-Link™ networks interface cards for Profibus-DP support following protocols:  
ƒ
ƒ
ƒ
DP-V0 Master/Scanner Class-1 & -2 and Slave modes simultaneously  
DP-V0 Slave passive mode only  
DP-V1 Master Class-1 & -2 (for PCU card)  
DP Master features  
Access Modes  
DPV0 Master/Scanner Class-1 for optimized exchange of input/output data with the slaves  
(Data_Exchange).  
DP-V0 Master Class-2 for:  
ƒ
ƒ
ƒ
ƒ
Slave diagnostics  
Reading inputs/outputs of a slave  
Reading configuration data  
Changing the slave address.  
DP-V1 Master Class-1 & -2:  
ƒ
ƒ
ƒ
ƒ
ƒ
Read Data Block Class 1  
Write Data Block Class 1  
Read Data Block Class 2  
Write Data Block Class 2  
Abort Data Block Comm Class 2  
Yes (able to share the bus with other DP masters connected on the network)  
Multi-master mode  
Watchdog control  
Yes, enables the master to switch into error if no data has been exchanged during this period  
(Bus Fault)  
ƒ
Memory of I/O data image:  
o
o
o
o
PC/104:  
PCI-Universal: up to 8Kbytes  
PCI Express:  
CompactPCI:  
up to 2Kbytes  
Input/Output Data  
up to 8Kbytes  
up to 4Kbytes  
ƒ
ƒ
Manage up to 244 data bytes per slave  
Automatic organization of I/O data in the DPRAM memory  
Connect up to 126 slaves  
Max. DP Slave  
Yes (i.e. user gets the data up to 122 bytes of a slave from one and the same DP cycle)  
Direct access to variable types (bit, byte, word, double word)  
Data consistency  
Data format  
Run simultaneously with Master modes.  
Local DP slave  
Offers data exchange with another master on the network. The size of the input and output data  
is user-definable, and all exchange combinations are possible (from 0 to 244 bytes). The slave  
can ensure data consistency up to 122 bytes. (see DP-Slave features below for details).  
DP Slave passive features  
Access Mode  
DP-V0 Slave passive (no management of Profibus token)  
Configurable from 0 to 244 bytes  
Input memory size  
Output memory size  
Slave address  
GSD files  
Configurable from 0 to 244 bytes  
Configurable from 0 to 126 by software configuration  
Provided on the CD-Rom  
Data Format  
Configurable Intel or Motorola  
Address Assignment  
Master (Set_Slave_Address)  
Not supported  
Not supported  
Extended Diagnostic  
Direct-Link™ Profibus-DP  
Software tools  
The core of BradCommunications™ Direct-Link™ PC Network Interface cards lies in  
effective software tools enabling fast integration of industrial communication into your  
applications.  
More precisely, Direct-Link™ package includes configuration software called Console  
used to set up card, network and equipments connected to the fieldbus. The Console  
performs dynamic network diagnostic and allows defining access items to the  
input/output data used by the software interfaces (OPC server, ActiveX Control,  
DAServer, DDE/SuiteLink server).  
The console is common to all fieldbuses offer as EtherNet/IP, PROFINET IO, Modbus  
TCP, DeviceNet and CANopen. Other great features managed by the Console:  
- Powerful Graphical User Interface  
- Automatic detection of cards plugged into the host computer  
- User configuration manager: create, backup and restore many user configurations  
- Manual or Automatic device configuration  
- Device Configuration -  
- Profibus scanner (automatic configuration by detection of slaves connected)  
- GSD library. Add/Remove GSD file  
- Diagnostic monitor; scan devices connected on the bus, able to change DP slave  
address  
- Card Status indicator: allows you to quickly find the initialization status of each  
card  
- Profibus Network Monitoring -  
- Troubleshooting & Testing tool –  
Ordering Information  
Part Number  
DRL-DPM-PCU  
SAP  
Product Description  
BradCommunications™ Direct-Link™ PCU-DPIO Profibus-  
DP Master/Slave 12 Mbps, PCI-Universal bus, 3.3/5V  
1120110008  
BradCommunications™ Direct-Link™ PCU-DPIO Profibus-  
DP Master/Slave 12 Mbps, PCI Express 1x  
DRL-DPM-PCIE 1120115028  
- Browsing of OPC Server -  
BradCommunications™ Direct-Link™ CPCI-DPIO Profibus-  
DP Master/Slave 12 Mbps, CompactPCI bus 3U  
DRL-DPM-CPI  
DRL-DPM-104  
1120185004  
1120130003  
BradCommunications™ Direct-Link™ PC104-DPIO  
Profibus-DP Master/Slave 12 Mbps, PC/104 bus  
To contact us: www.woodhead.com  
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136  
Europe:  
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –  
United Kingdom: +44 1495 356300  
Asia:  
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717  
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950  
Brad is a registered trademark and BradCommunications and applicom are trademarks of Molex Incorporated. © 2008 Molex  

相关型号:

DRL-DPS-SRM

Connect Profibus to Modbus Serial devices
MOLEX

DRL-DVN-104

BradCommunications Direct-Link PC104-DVNIO DeviceNet card, PC/104 bus
MOLEX

DRL-DVN-PCU

Direct-Link PCU-DVNIO DeviceNet Mstr/Slave card (Univ. PCI)
MOLEX

DRL-EIP-PCIE

BradCommunications Direct-Link PCIE-ETHIO Ethernet card for EtherNet/IP Scanner/Adapter
MOLEX

DRL-EMB-PCIE

BradCommunications Direct-Link PCIE-ETHIO Ethernet card for Modbus TCP/ UDP Client
MOLEX

DRL-EMB-PCU

BradCommunications Direct-Link PCU-ETHIO Ethernet card for Modbus TCP/UDP Client
MOLEX

DRL-EPN-PCIE

BradCommunications Direct-Link PCIE-ETHIO Ethernet card for PROFINET IOController & IO-Device
MOLEX

DRL-EPN-PCU

BradCommunications Direct-Link PCU-ETHIO Ethernet card for PROFINET IOController & IO-Device
MOLEX

DRL-SIE-SWF

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection
MOLEX

DRL-SIE-SWF-P

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection
MOLEX

DRL-SIE-SWF-S

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Software Key Protection
MOLEX

DRL-SIE-SWF-U

DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - USB Dongle Protection
MOLEX