DRL-DPM-PCIE [MOLEX]
Direct-Link PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x; 直接链接PCU - DPIO PROFIBUS- DP主/从12 Mbps时, PCI Express的1X型号: | DRL-DPM-PCIE |
厂家: | Molex |
描述: | Direct-Link PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x |
文件: | 总6页 (文件大小:1325K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
This document was generated on 05/18/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Part Number:
Status:
1120115028
Active
EU RoHS
ELV and RoHS
Compliant
China RoHS
Description:
Direct-Link™ PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x
REACH SVHC
Not Reviewed
Halogen-Free
Status
Documents:
Drawing (PDF)
RoHS Certificate of Compliance (PDF)
Not Reviewed
Need more information on product
environmental compliance?
General
Product Family
Series
Network Interface
112011
Approvals
Comments
CE
Email productcompliance@molex.com
For a multiple part number RoHS Certificate of
Compliance, click here
Profibus DP-V0 (Master & Slave). . PROFIBUS DP-V1
(Master)
Profibus: 9.6 kbps to 12 Mbps
N/A
Communication Speed
MAC Address
Mounting Style
Product Name
Protocol
Please visit the Contact Us section for any
non-product compliance questions.
N/A
Direct-Link®
Profibus* DP
Profibus* Card
Type
Search Parts in this Series
112011Series
Physical
Channels
1
Interface
Profibus*
Network Connection Type
Packaging Type
Processor
D-Sub Female (9 pin)
Individual Carton
AMD SC520
0°C to +65°C
Temperature Range - Operating
Electrical
Current - Maximum Input
EMC
5.5W
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, IEC
61000-6-2
3.3V
Supply Voltage
Material Info
Old Part Number
DRL-DPM-PCIE
SD-112011-0008
Reference - Drawing Numbers
Sales Drawing
This document was generated on 05/18/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
BradCommunications™ Direct-Link™ Profibus-DP network
interface cards allow deterministic I/O data acquisition
for PC-based control applications.
27 Jan. 10
DW200591
Direct-Link™ Profibus-DP
Data acquisition for real time Control applications
Features
• NEW! RoHS compliant
• Connect PC-Based Control
applications directly to I/O
devices
PCI-Universal
PC/104
• Protocols supported:
Profibus-DP V0 Master/Slave
Class-1 & 2
PCI Express
Profibus-DP V1 Master Class-1 &
2 (for PCI-Universal card only)
Profibus-DP Slave passive
• Available in various card form
factor: PC/104, PCI-Universal and
CompactPCI 3U
CompactPCI
Overview
• 1 Serial or Ethernet port for
remote configuration
and diagnostic
BradCommunications™ Direct-Link™ is a low range of automation components for
industrial communication. It includes a variety of products such as diagnostic tools,
intelligent connectors, tunneling gateways, fieldbuses network interface cards, and
software drivers for industrial networks.
• Automatic devices detection on
the network
Simple as they are affordable, BradCommunications™ Direct-Link™ products allow
you to acquire the equipment to develop your architectures and industrial
applications at a lower cost.
• Embedded Communication on
the card for powerful data
throughput
Direct-Link™ products are characterized by their simple use and fast
implementation; they are modular and scalable. Moreover, they are designed to be
easily embedded into computerized systems and are available in a wide selection
of form factors.
• Configuration stored in the device
(Flash memory), with auto boot
mode
Powerful Network Interface card
Particularly, the BradCommunications™ Direct-Link™ Profibus-DP interface
cards are equipped with 1 Profibus port handling Profibus protocol in Master
and/or Slave modes up to 12 Mbps.
OS supported
Standard package
• Windows 32-bit (XP SP1/ 2000 SP4 /
NT SP6, 2003 Server), Ardence
RTX
A smart A.D.M (Automatic Dual port ram Mapping) mechanism avoids the I/O tags
configuration in the Dual Port RAM of the card. More than a simple I/O acquisition
card, the Direct-Link™ interface cards provide the applications with additional
information such as: device status and diagnostics, process data read/write
monitoring, communication tools for troubleshooting, hardware and software
Watchdog, etc..
Free Download
• Windows XP Embedded, QNX,
VxWorks, Linux, Phar Lap ETS,
DOS
The communication layers are completely embedded on the cards, allowing easy
and fast communication with field devices resulting in remarkable application
performance.
Woodhead is a member of PTO (PROFIBUS
Trade Organization), PNO (PROFIBUS
Nutzerorganisation e. V.) and France
Profibus.
Product package includes:
Graphical console for configuration and diagnostic tools
Data servers (Multi-protocol OPC DA 3.0 & 2.05, ActiveX, DAServer,
FastDDE/SuiteLink)
I/O libraries for Windows (DLL) and Ardence's hard real time extensions
(RTX)
Static library for non-windows OS
Drivers for soft-logic packages
Technical data
Direct-Link™
PCU-DPIO
Direct-Link™
PCIE-DPIO
Key Benefits
• Fast data exchange (on-board processor take off the load of the host CPU)
• Speed up to 12 Mbps
• Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS
• DP-V0 Master Class 1 & 2/Slave simultaneously
• DP-V1 Master Class 1 & 2
Hardware
PCI-Universal 3.3/5V, PCI-X compatible
AMD SC520, 133 Mhz
PCI Express 1x
Unit
AMD SC520, 133 Mhz
UART High Speed
Processor
Profibus ASIC
UART High Speed
16 Mbytes SDRAM
4 Mbytes
16 Mbytes SDRAM
4 Mbytes
Memory
Flash Memory
Interruption
Hardware Plug&Play
Hardware Plug&Play
Hardware Plug&Play (32 Kbytes)
Hardware Plug&Play (32 Kbytes)
DPRAM Address
Discrete Input
1 x Opto-coupled discrete input,
1 x Opto-coupled discrete input,
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
Discrete Output
168mm x 107mm (6.61" x 4.21")
5.5W (max. 1.2A)
168mm x 107mm (6.61" x 4.21")
5.5W (max. 1.2A)
Dimensions (LxW)
Consumption
Operating T°
Storage T°
0ºC (32ºF) up to +65°C (149°F)
0ºC (32ºF) up to +65°C (149°F)
-40º C (-40°F) up to +85ºC (185º F)
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
EMC Compliance
RoHS Compliance
Communication port
YES
YES
1 Profibus port (EN 50170)
1 Profibus port (EN 50170)
Port type
Profibus D-Sub, 9 pin, female
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps ↔ 12 Mbps
Profibus D-Sub, 9 pin, female
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps ↔ 12 Mbps
Connector
LED Indicator
Electrical Interface
Baud Rate
Port for remote configuration and diagnostic
Ethernet port
RJ45
Ethernet port
RJ45
Port Type
Connector type
LED indicators
Electrical interface
Speed
4 Leds - TX/RX/Link/100 Mbps
Ethernet
4 Leds - TX/RX/Link/100 Mbps
Ethernet
10/100 Mbps
10/100 Mbps
Technical data
Direct-Link™
PC104-DPIO
Direct-Link™
CPCI-DPIO
Key Benefits
• Fast data exchange (on-board processor take off the load of the host CPU)
• Speed up to 12 Mbps
• Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS
• DP-V0 Master Class 1 & 2/ Slave simultaneously
Hardware
PC/104 bus
CompactPCI bus, 5V
AMD SC520, 133 Mhz
ASPC2
Unit
AMD SC520, 100 Mhz
ASPC2
Processor
Profibus ASIC
Memory
8 Mbytes SDRAM
8 Mbytes SDRAM
512 kbytes
512 Kbytes
Flash Memory
Interruption
DPRAM Address
2, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15
From C8000 to DE000 (8 Kbytes used per card)
Hardware Plug&Play
Hardware Plug&Play (16 Kbytes)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)
Discrete Input
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
Discrete Output
95mm x 90mm (3.74" x 3.54")
5.5W (max. 1.2A)
100mm x 160mm (3.93" x 6.29") - 3U
5,5W (max. 1.2A)
Dimensions (LxW)
Consumption
Operating T°
Storage T°
0ºC (32°F) up to +65ºC (149ºF)
-40º C (-40°F) up to +85ºC (185º F)
0º C (32º F) ↔ +65º C (149º F)
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
EMC Compliance
RoHS Compliance
NO
YES
Communication port
Port type
1 Profibus port (EN 50170)
1 Profibus port (EN 50170)
Profibus D-Sub, 9 pin, female
In standard: HE13 (2 x 5 pins) or in option: 9-pin, Sub-
D, female
Connector
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps ↔ 12 Mbps
2 bicolor Leds: bus fault and communication status
RS485 optical insulation (500 V)
9.6 kbps ↔ 12 Mbps
LED Indicator
Electrical Interface
Baud Rate
Port for remote configuration and diagnostic
Asynchronous Serial port
HE13 (2 x 5 pins)
-
Asynchronous Serial port
9-pin, Sub-D, male
2 Leds - TX/RX
Port Type
Connector type
LED indicators
Electrical interface
Speed
RS232 – 2 signals
9600, 38400, 115200 bps
RS232 – 2 signals
9600, 38400, 115200 bps
Direct-Link™ Profibus-DP
Protocol Specifications
All BradCommunications™ Direct-Link™ networks interface cards for Profibus-DP support following protocols:
DP-V0 Master/Scanner Class-1 & -2 and Slave modes simultaneously
DP-V0 Slave passive mode only
DP-V1 Master Class-1 & -2 (for PCU card)
DP Master features
Access Modes
DPV0 Master/Scanner Class-1 for optimized exchange of input/output data with the slaves
(Data_Exchange).
DP-V0 Master Class-2 for:
Slave diagnostics
Reading inputs/outputs of a slave
Reading configuration data
Changing the slave address.
DP-V1 Master Class-1 & -2:
Read Data Block Class 1
Write Data Block Class 1
Read Data Block Class 2
Write Data Block Class 2
Abort Data Block Comm Class 2
Yes (able to share the bus with other DP masters connected on the network)
Multi-master mode
Watchdog control
Yes, enables the master to switch into error if no data has been exchanged during this period
(Bus Fault)
Memory of I/O data image:
o
o
o
o
PC/104:
PCI-Universal: up to 8Kbytes
PCI Express:
CompactPCI:
up to 2Kbytes
Input/Output Data
up to 8Kbytes
up to 4Kbytes
Manage up to 244 data bytes per slave
Automatic organization of I/O data in the DPRAM memory
Connect up to 126 slaves
Max. DP Slave
Yes (i.e. user gets the data up to 122 bytes of a slave from one and the same DP cycle)
Direct access to variable types (bit, byte, word, double word)
Data consistency
Data format
Run simultaneously with Master modes.
Local DP slave
Offers data exchange with another master on the network. The size of the input and output data
is user-definable, and all exchange combinations are possible (from 0 to 244 bytes). The slave
can ensure data consistency up to 122 bytes. (see DP-Slave features below for details).
DP Slave passive features
Access Mode
DP-V0 Slave passive (no management of Profibus token)
Configurable from 0 to 244 bytes
Input memory size
Output memory size
Slave address
GSD files
Configurable from 0 to 244 bytes
Configurable from 0 to 126 by software configuration
Provided on the CD-Rom
Data Format
Configurable Intel or Motorola
Address Assignment
Master (Set_Slave_Address)
Not supported
Not supported
Extended Diagnostic
Direct-Link™ Profibus-DP
Software tools
The core of BradCommunications™ Direct-Link™ PC Network Interface cards lies in
effective software tools enabling fast integration of industrial communication into your
applications.
More precisely, Direct-Link™ package includes configuration software called Console
used to set up card, network and equipments connected to the fieldbus. The Console
performs dynamic network diagnostic and allows defining access items to the
input/output data used by the software interfaces (OPC server, ActiveX Control,
DAServer, DDE/SuiteLink server).
The console is common to all fieldbuses offer as EtherNet/IP, PROFINET IO, Modbus
TCP, DeviceNet and CANopen. Other great features managed by the Console:
- Powerful Graphical User Interface
- Automatic detection of cards plugged into the host computer
- User configuration manager: create, backup and restore many user configurations
- Manual or Automatic device configuration
- Device Configuration -
- Profibus scanner (automatic configuration by detection of slaves connected)
- GSD library. Add/Remove GSD file
- Diagnostic monitor; scan devices connected on the bus, able to change DP slave
address
- Card Status indicator: allows you to quickly find the initialization status of each
card
- Profibus Network Monitoring -
- Troubleshooting & Testing tool –
Ordering Information
Part Number
DRL-DPM-PCU
SAP
Product Description
BradCommunications™ Direct-Link™ PCU-DPIO Profibus-
DP Master/Slave 12 Mbps, PCI-Universal bus, 3.3/5V
1120110008
BradCommunications™ Direct-Link™ PCU-DPIO Profibus-
DP Master/Slave 12 Mbps, PCI Express 1x
DRL-DPM-PCIE 1120115028
- Browsing of OPC Server -
BradCommunications™ Direct-Link™ CPCI-DPIO Profibus-
DP Master/Slave 12 Mbps, CompactPCI bus 3U
DRL-DPM-CPI
DRL-DPM-104
1120185004
1120130003
BradCommunications™ Direct-Link™ PC104-DPIO
Profibus-DP Master/Slave 12 Mbps, PC/104 bus
To contact us: www.woodhead.com
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136
Europe:
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –
United Kingdom: +44 1495 356300
Asia:
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950
Brad is a registered trademark and BradCommunications and applicom are trademarks of Molex Incorporated. © 2008 Molex
相关型号:
DRL-EIP-PCIE
BradCommunications Direct-Link PCIE-ETHIO Ethernet card for EtherNet/IP Scanner/Adapter
MOLEX
DRL-EMB-PCIE
BradCommunications Direct-Link PCIE-ETHIO Ethernet card for Modbus TCP/ UDP Client
MOLEX
DRL-EPN-PCIE
BradCommunications Direct-Link PCIE-ETHIO Ethernet card for PROFINET IOController & IO-Device
MOLEX
DRL-EPN-PCU
BradCommunications Direct-Link PCU-ETHIO Ethernet card for PROFINET IOController & IO-Device
MOLEX
DRL-SIE-SWF
DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection
MOLEX
DRL-SIE-SWF-P
DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Parallel Dongle Protection
MOLEX
DRL-SIE-SWF-S
DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - Software Key Protection
MOLEX
DRL-SIE-SWF-U
DirectLink SW1000 Software Drivers for Siemens S5, S7, TI - Full tags - USB Dongle Protection
MOLEX
©2020 ICPDF网 联系我们和版权申明