URB2415LD-30WR3 [MORNSUN]
DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, PACKAGE-6;型号: | URB2415LD-30WR3 |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 30W, Hybrid, PACKAGE-6 |
文件: | 总9页 (文件大小:4396K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
30W, Ultra wide input isolated & regulated dual/
single output, DC/DC converter
FEATURES
Ultra wide input voltage range (4:1)
High efficiency up to 90% with full load
High efficiency up to 82% with 5% load
No-load power consumption as low as 0.14W
Isolation voltage: 1.5K VDC
Input under-voltage protection, output short
circuit, over-voltage, over-current protection
Operating temperature range: -40℃to +80℃
Meet CISPR22/EN55022 CLASS A, without
external components
Six-sided metal shielding package
Reverse voltage protection available with
A2S(Chassis mounting) or A4S(35mm DIN-Rail
mounting)
IEC60950, UL60950, EN60950 approval
CB Patent Protection RoHS
URA_LD-30WR3 & URB_LD-30WR3 series are isolated 30W DC-DC products with 4:1 input voltage. They feature efficiency up to 90%, 1.5K VDC
isolation, operating temperature of -40℃ to +80℃, Input under-voltage protection, output short circuit protection, over-voltage protection,
over-current protection and EMI meets CISPR22/EN55022 CLASS A, which make them widely applied in data transmission device, battery
power supply device, tele-comunication device, distributed power supply system, remote control system, industrial robot fields. And
extension package A2S and A4S also enable them with reverse voltage protection.
Selection Guide
④
Input Voltage (VDC)
②
Output
Output Current
Efficiency
(%,Min./Typ.)
@ Full Load
Max.
Capacitive
Load(µF)
①
Certification
Part No.
Nominal
Output Voltage
(VDC)
③
⑤
Max.
(mA)(Max./Min.)
(Range)
URB2403LD-30WR3
3.3
6000/0
83/85
86/88
10000
URB2405LD-30WR3
URB2409LD-30WR3
URB2412LD-30WR3
URB2415LD-30WR3
URB2424LD-30WR3
URA2405LD-30WR3
URA2412LD-30WR3
URA2415LD-30WR3
URA2424LD-30WR3
URB4803LD-30WR3
URB4805LD-30WR3
URB4812LD-30WR3
URB4815LD-30WR3
URB4824LD-30WR3
URA4805LD-30WR3
URA4812LD-30WR3
URA4815LD-30WR3
5
9
6000/0
3333/0
2500/0
2000/0
1250/0
±3000/0
±1250/0
±1000/0
±625/0
6000/0
6000/0
2500/0
2000/0
1250/0
±3000/0
±1250/0
±1000/0
10000
4700
2700
1680
680
86/88
88/90
UL/CE/CB
12
88/90
88/90
15
24
(9-36)
40
24
±5
±12
±15
±24
3.3
5
84/86
87/89
87/89
87/89
84/86
86/88
86/88
87/89
87/89
84/86
86/88
86/88
2000
1250
680
CE
470
10000
10000
2700
1680
680
12
UL/CE/CB
15
48
(18-75)
80
24
±5
±12
±15
2000
1250
680
CE
Notes:①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example
URB2405LD-30WHR3A2S is chassis mounting of with heat sink,URB2405LD-30WR3A4S is DIN-Rail mounting of without heat sink; If the application has a
higher requirement for heat dissipation, you can choose modules with heat sink;
②A2S (wiring) and A4S (rail) Model due to input reverse polarity protection function, input voltage range the minimum value and starting voltage is higher
than 1VDC DIP package;
③Absolute maximum rating without damage on the converter, but it isn't recommended;
④Efficiency is measured In nominal input voltage and rated output load;A2S (wiring) and A4S (rail) Model due to input reverse polarity protection,
minimum efficiency greater than Min.-2 is qualified;
⑤ The capacitive loads of positive and negative outputs are identical.
2017.01.18-A/5
Page 1 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Input Specifications
Min.
--
Typ.
970/60
1420/60
1388/6
474/20
710/20
702/5
40
Max.
993/100
1453/100
1488/12
485/30
726/35
744/10
--
Unit
mA
Item
Operating Conditions
3.3V output
5V output
Others
24VDC nominal input series,
nominal input voltage
--
--
Input Current
(full load / no-load)
3.3V output
5V output
Others
--
48VDC nominal input series,
nominal input voltage
--
--
Reflected Ripple Current
Surge Voltage (1sec. max.)
Nominal input voltage
--
24VDC nominal input series
48VDC nominal input series
24VDC nominal input series
48VDC nominal input series
24VDC nominal input series
48VDC nominal input series
-0.7
-0.7
--
--
50
--
100
--
9
VDC
ms
Starting Voltage
--
--
18
6.5
5.5
12.0
--
--
Shutdown Voltage
15.5
10
--
Starting Time
Input Filter
Hot Plug
Nominal input voltage & constant resistance load
--
Pi filter
Unavailable
Ctrl suspended or connected to TTL high level
(3.5-12VDC)
Module switch on
Ctrl pin connected to GND or low level
Ctrl *
Module switch off
(0-1.2VDC)
--
5
8
mA
Input current when switched off
Note: *The voltage of Ctrl pin is relative to input pin GND.
Output Specifications
Item
Operating Conditions
Min.
--
Typ.
±1
Max.
±3
Unit
5%-100% load
0%-5% load
Output Voltage Accuracy
--
±1
±5
Positive output
Negative output
Positive output
Negative output
--
±0.2
±0.5
±0.5
±0.5
±0.5
±1
Full load, the input voltage is
from low voltage to high voltage
Line Regulation
--
%
--
±1
①
Load Regulation
5%-100% load
--
±1.5
Dual output, main output 50% load,
Supplement output from 10% - 100% load
Cross Regulation
--
--
±5
Transient Recovery Time
--
--
--
300
±5
500
±8
µs
%
25% load step change,
3.3V/5V/±5V output
nominal input voltage
Full load
Transient Response Deviation
Temperature Coefficient
Others
±3
±5
%/℃
Mv p-p
--
±0.03
100
--
--
--
--
50
Singe output
Dual output
20MHz bandwidth, nominal input
voltage, 100% load
②
Ripple & Noise
50
150
--
Trim
±10
%Vo
%Io
Output Over-voltage Protection
110
110
--
--
160
190
Output Over-current Protection Input voltage range
Short circuit Protection
Hiccup, Continuous, self-recovery
Note: ①When testing from 0% -100%load working conditions, load regulation index of ±5%;
②Ripple and noise are measured by “parallel cable” method, please see DC-DC Converter Application Notes for specific operation.
2017.01.18-A/5
Page 2 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
General Specifications
Item
Operating Conditions
Min.
Typ.
--
Max.
--
Unit
Input-output, with the test time of 1 minute and the
leak current lower than 1mA
Insulation Voltage
1500
VDC
Input-output, insulation voltage 500VDC/60sec.,
Ta=25℃, humidity=75%RH
Insulation Resistance
1000
--
--
--
--
M
Ω
Isolation Capacitance
Operating Temperature
Storage Temperature
Storage Humidity
Input-output, 100KHz/0.1V
2000
pF
see Fig. 1, Fig. 2, Fig. 3 and Fig. 4
-40
-55
5
--
--
+80
+125
95
℃
Non-condensing
--
%RH
Pin Welding Resistance
Temperature
℃
Welding spot is 1.5mm away from the casing, 10 seconds
--
--
+300
Vibration
10-55Hz, 10G, 30 Min. along X, Y and Z
Switching Frequency *
PWM mode
--
300
--
--
--
KHz
MIL-HDBK-217F@25℃, Full load(Ground, Benign,
controlled environment)
MTBF
1000
K hours
Note:* This series of products using reduced frequency technology, the switching frequency is test value of full load,When the load is reduced to below 50%, the
switching frequency decreases with decreasing load.
Physical Specifications
Casing Material
Aluminum alloy
Horizontal package( without heat sink)
Horizontal package( with heat sink)
A2S wiring package ( without heat sink)
A2S wiring package( with heat sink)
A4S rail package( without heat sink)
A4S rail package( with heat sink)
50.80*25.40*11.80 mm
50.80*25.40*16.30 mm
76.00*31.50*21.20 mm
76.00*31.50*25.10 mm
76.00*31.50*25.80 mm
76.00*31.50*29.70 mm
26g/48g/68g(Typ.)
Package Dimensions
without heat sink
with heat sink
Horizontal package/A2S wiring package/A4S rail package
Horizontal package/A2S wiring package/A4S rail package
Weight
34g/56g/76g(Typ.)
Cooling Method
Free air convection
EMC Specifications
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.6-② for recommended circuit)
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.7-② for recommended circuit)
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.6-② for recommended circuit)
Single output
CE
Dual output
EMI
Single output
RE
CISPR22/EN55022 CLASS A (Bare component)/ CLASS B (see Fig.7-
② for recommended circuit)
perf. Criteria B
Dual output
ESD
RS
IEC/EN61000-4-2 Contact ±4KV
IEC/EN61000-4-3 10V/m
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria A
perf. Criteria A
① for recommended circuit)
IEC/EN61000-4-4 ±2KV (see Fig.7-① for recommended circuit)
IEC/EN61000-4-5 line to line ±2KV (see Fig.6-①for recommended circuit)
IEC/EN61000-4-5 line to line ±2KV (see Fig.7-①for recommended circuit)
Single output IEC/EN61000-4-4 ±2KV (see Fig.6-
EFT
Dual output
Single output
Dual output
EMS
Surge
CS
Single output IEC/EN61000-4-6 3 Vr.m.s
Dual output IEC/EN61000-4-6 10Vr.m.s
2017.01.18-A/5
Page 3 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Product Characteristic Curve
Fig. 2
Apply model:URA2405LD-30W(H)R3(18-36V input voltage)、
URA2424LD-30W(H)R3(18-36V input voltage)、
URA4805LD-30W(H)R3(36-75V input voltage)、
URA2412LD-30W(H)R3、URA2415LD-30W(H)R3、
URA4812LD-30W(H)R3、 URA4815LD-30W(H)R3
Fig. 1
Apply model:URA2405LD-30W(H)R3(9-18V input voltage)、
URA2424LD-30W(H)R3(9-18V input voltage)、
URA4805LD-30W(H)R3(18-36V input voltage)
Fig. 4
Fig. 3
Apply model:URB2409LD-30W(H)R3、URB2412LD-30W(H)R3、
URB2415LD-30W(H)R3、URB2424LD-30W(H)R3、
URB4812LD-30W(H)R3、URB4815LD-30W(H)R3、
URB4824LD-30sW(H)R3
Apply model:URB2403LD-30W(H)R3、URB2405LD-30W(H)R3、
URB4803LD-30W(H)R3、URB4805LD-30W(H)R3
2017.01.18-A/5
Page 4 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Design Reference
1. Typical application
All the DC/DC converters of this series are tested according to the recommended circuit (see Fig. 5) before delivery.
If it is required to further reduce input and output ripple, properly increase the input & output of additional capacitors Cin and Cout or
select capacitors of low equivalent impedance provided that the capacitance is no larger than the max. capacitive load of the product.
Dual output:
+Vo
Vin
Cout
Cout
Single output
voltage
Dual output
voltage
Cout
(µF)
Cin
(µF)
Cout
(µF)
Cin
(µF)
Cin
0V
DC DC
(VDC)
(VDC)
GND
-Vo
Single output:
Vin
3.3/5/9
220
100
±5/±12/±15
±24
220
100
100
100
+Vo
0V
12/15/24
Cin
Cout
DC DC
GND
Fig. 5
2. EMC solution-recommended circuit
Parameter description
Model
Vin:24V
Vin:48V
Single output:
Choose according to actual input
current
FUSE
CY1
LCM
FUSE
Vin
Vin
+Vo
0V
MOV
C0
C1
S20K30
S14K60
C3
+
+
LOAD
DC/DC
C2
680µF/50V
330µF/50V
4.7µF/50V
330µF/100V
330µF/100V
2.2µF/100V
C1
C0
MOV
GND
GND
①
②
2
CY
C2
C3
Refer to the Cout in Fig.5
Fig. 6
1mH, recommended to use
MORNSUN’s FL2D-30-102s
LCM
Notes: Part ①in the Fig. 6 is used for EMS test and part ②for EMI filtering;
selected based on needs.
CY1、CY2
1nF/2KV
Model
FUSE
Vin:24V
Vin:48V
Choose according to actual input
current
Dual output:
CY1
FUSE
MOV
C0
S20K30
S14K60
Vin
Vin
+Vo
-V0
680µF/50V
2.2µF/50V
2.2µF/50V
330µF/50V
330µF/100V
2.2µF/100V
2.2µF/100V
330µF/100V
C4
+
+
C3
LOAD
DC/DC
C2
C0
C1
MOV
C1
GND
GND
LDM1
C2
①
②
2
CY
C3
Fig.7
C4
Refer to the Cout in Fig.5
3.3µH
Notes: Part ①in the Fig. 7 is used for EMS test and part ②for EMI filtering;
LDM1
CY1、CY2
selected based on needs.
2.2nF/400VAC Safety Y Capacitor
3. Application of Trim and calculation of Trim resistance
Vo’
Calculation formula of Trim resistance:
Vo’
aR2
R2-a
Vref
Vo’-Vref
R1
-R3
up:
RT=
RT=
a=
a=
R1
R2
RT
R1
R3
Vref
R2
Trim
R3
Vref
R2
aR1
R1-a
Vo’-Vref
Vref
Trim
down:
-R3
RT
RT is Trim resistance ,a is a self-defined
parameter, with no real meaning.
Vo’ for the actual needs of the up or
down regulated voltage
0V
Trim down
0V
Trim up
Applied circuits of Trim (Part in broken line is the interior of models)
2017.01.18-A/5
Page 5 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
R1(KΩ)
4.801
R2(KΩ)
2.87
R3(KΩ)
12.4
10
Vout(VDC)
Vref(V)
1.24
2.5
3.3
5
2.883
2.87
9
7.500
2.87
15
2.5
12
15
24
11.000
14.494
24.872
2.87
15
2.5
2.87
15
2.5
2.87
17.8
2.5
4. It is not allowed to connect modules output in parallel to enlarge the power
5. For more information please find DC-DC converter application notes on www.mornsun-power.com
Horizontal Package (without heat sink) Dimensions and Recommended Layout
2017.01.18-A/5
Page 6 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
Horizontal Package (with heat sink) Dimensions
URA_LD-30WR3A2S & URB_LD-30WR3A2S(without heat sink) Dimensions
2017.01.18-A/5
Page 7 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
URA_LD-30WR3A2S & URB_LD-30WR3A2S(with heat sink) Dimensions
URA_LD-30WR3A4S & URB_LD-30WR3A4S(without heat sink) Dimensions
2017.01.18-A/5
Page 8 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
DC/DC Converter
URA_LD-30WR3 & URB_LD-30WR3 Series
URA_LD-30WR3A4S & URB_LD-30WR3A4S(with heat sink) Dimensions
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com.
Horizontal Packing Bag Number: 58200035(without heat sink), 58200051(with heat sink), A2S/A4S Packing Bag Number: 58220022;
2. The maximum capacitive load offered were tested at input voltage range and full load;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25℃, humidity<75%RH with nominal
input voltage and rated output load;
4. All index testing methods in this datasheet are based on Company’s corporate standards;
5. We can provide product customization service, please contact our technicians directly for specific information;
6. Specifications are subject to change without prior notice.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: info@mornsun.cn
2017.01.18-A/5
Page 9 of 9
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
相关型号:
URB2415S-10WR3
10W, Ultra wide input, isolated & regulated single output, SIP package, DC-DC converter
MORNSUN
URB2415S-6WR3
6W, Ultra wide input, isolated & regulated single output, SIP package, DC-DC converter
MORNSUN
URB2415YMD-15WR3
15W isolated DC-DC converter DIP package with Ultra-wide Input and Regulated Single Output
MORNSUN
URB2415YMD-20WR3
20W isolated DC-DC converter DIP package with Ultra-wide Input and Regulated Single Output
MORNSUN
URB2415ZP-10WR3
10W, Ultra wide input, isolated & regulated dual/ single output, DIP package, DC-DC converter
MORNSUN
URB2415ZP-6WR2
DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, ROHS COMPLIANT, PACKAGE-7
MORNSUN
©2020 ICPDF网 联系我们和版权申明