WRA2405YMD-6W [MORNSUN]
DUAL/SINGLE OUTPUT DC-DC CONVERTER; 双/单路输出DC -DC转换器型号: | WRA2405YMD-6W |
厂家: | MORNSUN SCIENCE& TECHNOLOGY LTD. |
描述: | DUAL/SINGLE OUTPUT DC-DC CONVERTER |
文件: | 总2页 (文件大小:127K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WRA_YMD-6W & WRB_YMD-6W Series
6W, WIDE INPUT ISOLATED & REGULATED
DUAL/SINGLE OUTPUT DC-DC CONVERTER
multi-country patent protection RoHS
FEATURES
PRODUCT PROGRAM
Efficiency up to 86%
DIP Package
Operating Temperature: -40°C to +85°C
1.5KVDC Isolation
Metal Case Package
No Heat sink Required
Industry Standard Pin out
MTBF>1,000,000 hours
RoHS Compliance
Input
Output
Part
Number
Efficiency
(%, Typ)
Voltage (VDC)
Current (mA)
Voltage
(VDC)
Nominal Range
Max*
11
Max
Min
±60
±25
±20
120
50
WRA0505YMD-6W
WRA0512YMD-6W
WRA0515YMD-6W
WRB0505YMD-6W
WRB0512YMD-6W
WRB0515YMD-6W
WRA1205YMD-6W
WRA1212YMD-6W
WRA1215YMD-6W
WRA1224YMD-6W
WRB1205YMD-6W
WRB1212YMD-6W
WRB1215YMD-6W
WRB1224YMD-6W
WRA2405YMD-6W
WRA2412YMD-6W
WRA2415YMD-6W
WRA2424YMD-6W
WRB2403YMD-6W
WRB2405YMD-6W
WRB2412YMD-6W
WRB2415YMD-6W
WRB2424YMD-6W
WRA4805YMD-6W
WRA4812YMD-6W
WRA4815YMD-6W
WRA4824YMD-6W
WRB4803YMD-6W
WRB4805YMD-6W
WRB4812YMD-6W
WRB4815YMD-6W
WRB4824YMD-6W
±5
±12
±15
5
±600
±250
±200
1200
500
76
80
82
76
80
82
79
82
84
82
79
82
84
82
81
84
86
84
78
80
84
86
85
80
84
85
86
78
80
84
86
85
5
4.5-9
12
15
400
40
±5
±600
±250
±200
±125
1200
500
±60
±25
±20
±13
120
50
±12
±15
±24
5
12
9-18
20
APPLICATIONS
12
The WRA_YMD-6W/WRB_YMD-6W Series
are specially designed for applications where a
wide range input voltage power supplies are
15
400
40
24
250
25
±5
±600
±250
±200
±125
1500
1200
500
±60
±25
±20
±13
150
120
50
isolated from the input power supply in
a
±12
±15
±24
3.3
5
distributed power supply system on a circuit
board.
These products apply to:
24
18-36
40
1) Where the voltage of the input power supply
is wide range (voltage range ≤2:1);
2) Where isolation is necessary between input
and output (Isolation voltage ≤1500VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
12
15
400
40
24
250
25
±5
±600
±250
±200
±125
1500
1200
500
±60
±25
±20
±13
150
120
50
±12
±15
±24
3.3
5
48
36-72
80
12
MODEL SELECTION
15
400
40
WRA2415YMD-6W
24
250
25
Rated Power
Package Style
Output Voltage
*Input voltage can’t exceed this value, or will cause the permanent damage.
Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
Input Voltage
Product Series
OUTPUT SPECIFICATION
Item
Test Conditions
Min
0.6
Typ
Max
6
Units
W
Output Power
See above products program
Positive Voltage Accuracy Refer to recommended circuit
Negative Voltage Accuracy Refer to recommended circuit
±1
±3
±3
±5
%
Load Regulation
From 10% To 100% load
±0.5
±0.2
0.02
20
±1*
±0.5
Line Regulation(at full load) Input voltage from low to high
MORNSUN Science & Technology co.,Ltd.
Address: 2th floor 6th building, Huangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Temperature Drift(Vout)
Ripple**
Refer to recommended circuit
20MHz bandwidth
%/°C
50
mVp-p
Noise**
20MHz bandwidth
50
100
Fax: 86-20-38601272
Http://www.mornsun-power.com
Switching Frequency
100% load, nominal Input voltage
300
KHz
* Dual output models unbalanced load: ±5%.
* * Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_YMD-6W & WRB_YMD-6W
A/2-2008
Page 1 of 2
Recommended Circuit
COMMON SPECIFICATIONS
All the WRA_YMD-6W & WRB_YMD-6W Series
have been tested according to the following
recommended testing circuit before leaving
factory. This series should be tested under load.
Never be tested under no load (see Figure 1).
Item
Test Conditions
Min
Typ
40
Max
95
Units
%
Storage Humidity Range
Operating temperature
Storage Temperature
Lead Temperature
Temp. Rise at Full Load
Isolation voltage
Isolation resistance
Isolation capacitance
No-load power consumption
Cooling
-40
-55
85
125
300
°C
1.5mm from case for 10 seconds
Dual Output
Tested for 1 minute and 1mA max 1500
VDC
MΩ
pF
+Vout
Vin
Test at 500VDC
Input/Output
1000
Cin
0V
DC DC
100
500
GND
-Vout
mW
Single Output
Free Air Convection
+Vout
0V
Vin
Short Circuit Protection
Case Material
Continuous, automatic recovery
Aluminium alloy
Cin
DC DC
(Figure 1)
GND
MTBF
1000
K hours
g
Weight
Note:
15
If you want to further decrease the input/output
ripple, you can increase capacitance properly or
choose capacitors with low ESR. However, the
capacitance of the output filter capacitor must be
proper. If the capacitance is too big, a startup
problem might arise. For every channel of output,
provided the safe and reliable operation is
ensured, the greatest capacitance of its filter
capacitor sees (Table 1). General:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless
otherwise specified.
2. See below recommended circuits for more details.
TYPICAL CHARECTERISTICS
Cin: 5V&12V
24V&48V
100μF
10μF-47μF
Cout: 10μF/100mA
Output External Capacitor Table(Table 1)
100
Operating Temp.(
C )
Single Vout
(VDC)
Cout
(uF)
Dual Vout
(VDC)
Cout
(uF)
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
3.3
5
2200
1000
680
±5
±9
±12
±15
-
680
470
330
220
-
First Angle Projection
(1.000)
25.40
9
10.16 10.16
(0.400) (0.400)
12
15
24
470
Dual Output
330
220
-
-
3
Bottom view
Input Current
When it is used in unregulated power supply, be
sure that the fluctuating range of the power supply
and the rippled voltage do not exceed the module
standard. Input current of power supply should
afford the startup current of this kind of DC/DC
module. (Figure 2).
Single Output
5.08
(0.200)
Side view
General: Ip ≤1.4*Iin-max
FOOTPRINT DETAILS
0.50
(0.020)
Dual
GND
Vin
Single
GND
Pin
1
Ip
Vin
+Vo
2
3
4
5
Note:
Unit:mm(inch)
Pin diameter:0.80mm(0.031inch)
Pin diameter tolerances: 0.05mm( 0.002inch)
General tolerances: 0.25mm( 0.010inch)
+Vo
0V
No Pin
0V
-Vo
Input Voltage
Range
APPLICATION NOTE
Input Voltage (V)
Requirement on output load
In order to ensure the product operate efficiently and reliably, in addition to a max load (namely
full load), a minimum load is specified for this kind of DC/DC converter. Make sure the specified
range of input voltage is not exceeded, the minimum output load no less than 10% load. If the
actual load is less than the specified minimum load, the output ripple may increase sharply while its
efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading, or contact our company for other lower output power
products.
No parallel connection or plug and play.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_YMD-6W & WRB_YMD-6W
A/2-2008
Page 2 of 2
相关型号:
WRA2405YMT-2W
2W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC/DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YMT-3W
3W, WIDE INPUT , ISOLA TED & REGULATED SINGLE/DUAL OUTPUTDC/DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YQD-20W
20W,WIDEINPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUTDC-DCCONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YQD-40W
30W~40W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YS-1W
WIDE INPUT,ISOLATED & REGULATED Dual Output SIP DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YS-2W
WIDE INPUT,ISOLATED & REGULATED Dual Output SIP DC/DC ConverterWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YS-3W
3W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405YT-2W
2W,WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLEOUTPUTDC/DCCONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405ZD-1W5
1.5W, WIDE INPUT, ISOLATED®ULATED DUAL OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405ZD-3W
3W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405ZD-4W
4W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
WRA2405ZD-5W
5W, WIDE INPUT, ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTERWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
MICRODC
©2020 ICPDF网 联系我们和版权申明