MSSW003 [MOSEL]
14 Talking Clock/Watch; 14语音报时钟/手表型号: | MSSW003 |
厂家: | MOSEL VITELIC, CORP |
描述: | 14 Talking Clock/Watch |
文件: | 总8页 (文件大小:96K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MSSW003
MOSEL VITELIC INC.
April 1996
14" Talking Clock/Watch
Features
Setting alarm time in hour and minute.
Single power can operate at 3.0V or 4.5V (LCD
dependent)
PM flag displayed at 12 HR format after 12:00.
12/24 HR format selectable by pressing HOUR
key when in regular mode.
3 1/2 gidits LCD display with 5 information flags,
in 1/2 duty 1/2 bias.
Two independent chime sentence groups for 12
& 24 HR chime modes. A group has 24 chime
sentences for 24 HR chime mode. The other
group has 12 sentences.
Based on the 32768 Hz quartz crystal.
Current output can drive 8 ohm speaker with a
transistor. Vout can drive buzzer directly.
Hour and minute digit adjustable individually by
pressing HR and MN key and can be repeat in
fast mode.
They are colon, PM, CHM, ALM, AL.
4 operation modes and easily operating :
Regular mode, current time adjust mode, Alarm
time adjust mode, Chime on/off & alarm on/off
mode.
The voice content is stored up to 14.5 seconds
at 6 KHz (15400h) and can be separated up to
64 sections.
The length of each section can be different and
is multiples of 100h.
Time rolling reading in 1 Hz flash on two colon
dots.
The length of a section with mute could be up to
8000h.
Automatic ramp up and ramp down.
Power on reset automatically.
Report current time by each TALK key trigger,
except in Alarm mode.
Automatic power down.
Current time display at regular mode.
Set alarm function on/off by setting ALM flag
on/off.
Report Alarm on/off status and display.
Report Chime on/off status and display.
Setting current time the dsiplay in flashing.
Alarm time will report at every setting.
Report Alarm sound with time when alarm time
is due.
Reset to regular mode when in other mode
without any key input for 20 - 40 seconds.
Voice output frequency can be tuned by external
resistor.
Mosel standard codes are available.
MSM9203 demo board (COB) is provided.
General Description
The Mosel SW003 is a monolithic CMOS LSI intelligent chip that is dedicated for clock/watch application with
time announcing & alarm warning. 10 sentences are built-in for report and adjusting time and alarm. 3 1/2
digits LCD with 3 information flags are interfaced. With Mosel Editing system, every human language can be
defined by user when manuafacturing.
Pages 9, 10, 11, 14 through 17 are provided herein. Pages 1 through 8 and 12, 13 are provided by file in DOS
format per request.
Taiwan
Taipei
Hongkong
U.S.A.
#1, Creation Road I,
Science - based Industrial Park,
Hsinchu, 30077
7F, #102 Sec. 3,
Ming Chung E. Road,
Taipei,105
#19 Dai Fu Street,
Taipo Industrial Estate,
Taipo, N.T.
#3910 North First Street,
San Jose,
CA. 65134-1501
U.S.A.
Taiwan, ROC
Taiwan, ROC
Hongkong
"taylor_hsiao@ccmail.mosel.com.tw"
TEL: 886-3-5770055
FAX: 886-3-5772788
FAX: 886-3-5784732
TEL: 852-2388-8277(MKO)
TEL: 852-2665-4883
FAX: 852-2664-2406
FAX: 852-2770-8011(MKO)
TEL: 886-2-5451213
FAX: 886-2-5451214
TEL: 1-408-433-6000
FAX: 1-408-433-0952
Specifications subject to change without notice, contact your sales representatives for the most recent information.
(PID 249** 04/96)
(1/17)
MOSEL VITELIC INC.
Preliminary
MSSW003
Legend
COB Informations
Copper pad for X'tal
Copper pad for LCD
Copper pad for LCD
Through hole
Alignment hole
Standing hole
2 cm
1
0
1 2
6
11
15 16
COM2
PM/AL
G2/A2
COM1
CHM/ALM
C3/B3
SPK
BZ
VDD
E C B
X'tal
8050
32.768 KHz
HOUR
MIN
TALK
MODE
GND
MOSEL-VITELIC
MSM9203-
INC @ 1996
V1M1 SN:
Specifications subject to change without notice, contact your sales representatives for the most recent information.
9/17
PID249** 04/96
MOSEL VITELIC INC.
Preliminary
MSSW003
Timing Diagrams
I. Mode key operation, selecting modes
Mode key
Mode 1
Mode 2
Mode 3
Mode 4
Mode 1
Status
Voice
Sentence 10
Sentence 1
Sent. 1
Sentence 10
Sentence 10
Sentence 10
II.a. Talk key in mode 1,2,4
Talk
Voice
II.b. Several Talk keys in mode 1,2,4
Talk
Sent. 1
Sentence 1
Voice
II.c. Long Talk key in mode 1,2,4
Talk
Sentence 1
Alarm (C4)
Alarm (C4)
Voice
II.d. Talk key in mode 3
Talk
Sentence 3
Voice
III.a. HR key in mode 1
2412 (HR)
12 hr.
24 Hr.
12 Hr.
Sent. 4
24 Hr.
Sent. 4
12 Hr.
Hour Format
III.b. HR key in mode 2,3
HR key
Voice
Sent. 4
Sent.4
Sent. 4
Sent. 4
III.c. HR key in mode 4 (initial state is OFF)
CHM (HR)
Voice
ON (sent. 9)
OFF (sent. 8)
Sent.5
ON (sent. 9)
Sent.5
IV.a. MN Key in mode 2,3
MN key
Sent.5
Sent.5
Sent.5
Sent.5
Voice
IV.b. MN key in mode 4 (initial state is OFF)
ALM (MN)
Voice
ON (sent.7)
OFF (sent.6)
ON (sent.7)
V.a. Talk at Alarm : (condition : Alarm time = 11:30, Alarm ON, Chime ON or OFF)
11:29
11:30
11:31
Current
Talk
Sentence 2
Sent. 2
Sentence 1
Voice
Specifications subject to change without notice, contact your sales representatives for the most recent information.
10/17
PID249** 04/96
MOSEL VITELIC INC.
Preliminary
MSSW003
V.b. Alarm function (conditions as V.a.)
11:29
11:30
11:31
Current time
Voice
Sentence 2
Sentence 2
Sentence 2
V.c. Key (mode or HR or MN) at Alarm (conditions as V.a.)
11:29
11:30
11:31
Current time
Key
Sentence 2
Sent. 2
XY:00
Voice
VI.a. Chime function : (conditions : Alarm OFF, Chime ON)
XX:59
XY:01
XY:01
Current time
Voice
Sentence 1
VI.b. Talk at Chime (conditions as VI.a)
XX:59
XY:00
Current time
Talk key
Voice
Sent. 1
Sentence 1
VI.c. Key (Mode or HR or MN) at Chime (conditions as VI.a)
XX:59
XY:00
XY:01
Current time
Key
Sentence 1
The number referred is pad number.
Voice
Application Circuits
COM2
1
COM2
PM/AL
C1
VSS
VEE
R2
X2
C1/ADEG1
4
5
6
3
2
30
29
28
27
26
25
24
23
22
L
C
D
32768Hz
X1
D2/B1
E2/F2
M
O
D
U
L
COUT
G2/A2
C2/B2
D4/COL
E3/F3
VDD
V2
MSSW003
7
8
E
Buzzer
V1
G3/A3D3
C3/B3
9
T1
10
HOUR
11
E4/F4
21
14 15 16 17 18 19
13
VSS
D1
VDD
G4/A4
20
12
MIN
HOUR
C4/B4
CHM/ALM
COM1
CHM/ALM
COM1
R1
+
VSS
Specifications subject to change without notice, contact your sales representatives for the most recent information.
11/17
PID249** 04/96
MOSEL VITELIC INC.
Preliminary
T I T L E
MSSW003
1<
<64
Product Request Form A : Voice Word Definitions : There are
words defined.
Voice Description Voice Length MuteLength W< o8r0d0T0ohtal 33
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
Addr-
ess
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h
00h 34
00h 35
00h 36
00h 37
00h 38
00h 39
00h 40
00h 41
00h 42
00h 43
00h 44
00h 45
00h 46
00h 47
00h 48
00h 49
00h 50
00h 51
00h 52
00h 53
00h 54
00h 55
00h 56
00h 57
00h 58
00h 59
00h 60
00h 61
00h 62
00h 63
00h
00h
00h
Length summ. of above 64 words
Signature & date
00h must be < 15400h
MVI Sales & date
Specifications is subject to change without notice, contact your sales representatives for the most recent information
14/17
PID249** 04/96
MOSEL VITELIC INC.
Preliminary
T I T L E
MSSW003
Product Request Form B : Minutes Reading Definitions Table
Entry
Minute
List of Entries (addresses)
:31
:32
:33
:34
:35
:36
:37
:38
:39
:40
:41
:42
:43
:44
:45
:46
:47
:48
:49
:50
:51
:52
:53
:54
:55
:56
:57
:58
:59
:60( :00)
Count
Note 1
:00
:01
:02
:03
:04
:05
:06
:07
:08
:09
:10
:11
:12
:13
:14
:15
:16
:17
:18
:19
:20
:21
:22
:23
:24
:25
:26
:27
:28
:29
:30
Note 2
Entry count summation of above 61 minutes =
Note 1. This minute reading is not read by sentence 5.
Note 2. This minute reading is read only by sentence 5.
Signature & date
MVI Sales & date
Specifications is subject to change without notice, contact your sales representatives for the most recent information
15/17
PID249** 04/96
MOSEL VITELIC INC.
Preliminary
T I T L E
MSSW003
Product Request Form C : Hour Reading Definitions
24 Hour Format Definition Table
12 Hour Format Definition Table
Entry
Count
Entry
Hour
01:
02:
03:
04:
05:
06:
07:
08:
09:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:(00:)
Hour
List of Entries (addresses)
List of Entries (addresses)
Count
01:(13:)
02:(14:)
03:(15:)
04:(16:)
05:(17:)
06:(18:)
07:(19:)
08:(20:)
09:(21:)
10:(22:)
11:(23:)
12:(24:)(00:)
Entry count summation of above 12 hours =
Entry count summation of above 3 tables =
(must be < 512)
These 3 tables are 24 hours,
12 hours and 61 minutes
Entry count summation of above 24 hours =
Signature & date
MVI Sales & date
Specifications is subject to change without notice, contact your sales representatives for the most recent information
16/17
PID249** 04/96
MOSEL VITELIC INC.
Preliminary
T I T L E
MSSW003
Product Request Form D : Vocabulary & Sentence Definitions
Definitions of Vocabularies
Address or
Address or
Address or
Vocabulary
Vocabulary
Vocabulary
KeyWord
KeyWord
KeyWord
C0
C1
C4.Sound
C5.RESET
C6.RETURN
C7
C10
C11
C12
C13
C14
C15
Note
Note
Hour.Table
C2
Minute.Table
C3.AM
C3.PM
Note
C8.CARRY
C9
Note. C5, C6, C8 all have to have length 800h or longer.
Definitions of Sentences
SentenceIndex
List of Vocabularies
1
2
3
4
5
6
7
8
9
10
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 1
Current Time
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
C
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 2
Alarm is due
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 3
Alarm time you set
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 4
Adjust hour
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 5
Adjust minute
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 6
Set alarm off
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 7
Set alarm on
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 8
Set chime off
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 9
Set chime on
C
1
C
2
C
3
C
4
C
5
C
6
C
7
C
8
C
9
10
C
11
C
12
C
13
C
14
C
15
C
16
C
Sentence 10
Mode changed
C
C
C
C
C
C
C
C
C
Signature & Date
MVI Sales & Date
Specifications is subject to change without notice, contact your sales representatives for the most recent information
17/17
PID249** 04/96
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明