M38510/31301BCA [MOTOROLA]

NAND Gate, LS Series, 2-Func, 4-Input, TTL, CDIP14, CERAMIC, DIP-14;
M38510/31301BCA
型号: M38510/31301BCA
厂家: MOTOROLA    MOTOROLA
描述:

NAND Gate, LS Series, 2-Func, 4-Input, TTL, CDIP14, CERAMIC, DIP-14

栅 CD
文件: 总18页 (文件大小:159K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
INCH-POUND  
MIL-M-38510/313B  
23 May 2003  
_
SUPERSEDING  
MIL-M-38510/313A  
22 July 1983  
MILITARY SPECIFICATION  
MICROCIRCUITS, DIGITAL, BIPOLAR LOW-POWER SCHOTTKY TTL,  
SCHMITT TRIGGER POSITIVE NAND GATES AND INVERTERS, MONOLITHIC SILICON  
Inactive for new design after 18 April 1997.  
This specification is approved for use by all Departments  
and Agencies of the Department of Defense.  
1. SCOPE  
1.1 Scope. This specification covers the detail requirements for monolithic silicon, low-power Schottky TTL,  
Schmitt trigger positive NAND gate and inverter microcircuits. Two product assurance classes and a choice of case  
outlines and lead finishes are provided for each type and are reflected in the complete part number. For this product,  
the requirements of MIL-M-38510 have been superseded by MIL-PRF-38535, (see 6.3).  
1.2 Part number. The part number should be in accordance with MIL-PRF-38535, and as specified herein.  
1.2.1 Device types. The device types should be as follows:  
Device type  
Circuit  
01  
02  
03  
Dual 4 input, Schmitt trigger positive NAND gate  
Hex Schmitt trigger inverter  
Quad 2 input Schmitt trigger positive NAND gate  
1.2.2 Device class. The device class should be the product assurance level as defined in MIL-PRF-38535.  
1.2.3 Case outlines. The case outlines should be as designated in MIL-STD-1835 and as follows:  
Outline letter  
Descriptive designator  
Terminals  
Package style  
A
B
C
D
X
2
GDFP5-F14 or CDFP6-F14  
GDFP4-F14  
GDIP1-T14 or CDIP2-T14  
GDFP1-F14 or CDFP2-F14  
CQCC2-N20  
14  
14  
14  
14  
20  
20  
Flat pack  
Flat pack  
Dual-in-line  
Flat pack  
Square leadless chip carrier  
Square leadless chip carrier  
CQCC1-N20  
Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in  
improving this document should be addressed to: Commander, Defense Supply Center Columbus, ATTN:  
DSCC-VAS, P. O. Box 3990, Columbus, OH 43216-5000, by using the self addressed Standardization  
Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.  
AMSC N/A  
FSC 5962  
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.  
MIL-M-38510/313B  
1.3 Absolute maximum ratings.  
Supply voltage range ............................................................................. -0.5 V dc to +7.0 V dc  
Input voltage range ................................................................................ -1.5 V dc at -18 mA to +5.5 V dc  
Storage temperature range .................................................................... -65° to +150°C  
Maximum power dissipation, (PD) 1/  
Device type 01 ..................................................................................... 38.5 mW dc  
Device type 02 ..................................................................................... 115.5 mW dc  
Device type 03 ..................................................................................... 77 mW dc  
Lead temperature (soldering, 10 seconds) ............................................. +300°C  
Thermal resistance, junction to case (θJC):  
Cases A, B, C, D, X, and 2 ................................................................... (See MIL-STD-1835)  
Junction temperature (TJ) 2/ ................................................................... +175°C  
1.4 Recommended operating conditions.  
Supply voltage (VCC) .............................................................................. +4.5 V dc minimum to +5.5 V dc  
maximum  
Minimum high level input voltage (VIH) ................................................... +1.4 V dc  
Maximum low level input voltage (VIL) .................................................... +1.0 V dc  
Normalized fanout (each output) 3/ ....................................................... 10 maximum  
Case operating temperature range (TC) ................................................. -55° to +125°C  
2. APPLICABLE DOCUMENTS  
2.1 Government documents.  
2.1.1 Specifications and Standards. The following specifications and standards form a part of this specification to  
the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the  
issue of the Departments of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited  
in the solicitation.  
SPECIFICATION  
DEPARTMENT OF DEFENSE  
MIL-PRF-38535  
STANDARDS  
DEPARTMENT OF DEFENSE  
-
Integrated Circuits (Microcircuits) Manufacturing, General Specification for.  
MIL-STD-883  
MIL-STD-1835  
-
-
Test Method Standard for Microelectronics.  
Interface Standard Electronic Component Case Outlines  
(Unless otherwise indicated, copies of the above specifications and standards are available from the  
Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)  
2.2 Order of precedence. In the event of a conflict between the text of this specification and the references cited  
herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws  
and regulations unless a specific exemption has been obtained.  
_______  
1/ Must withstand the added PD due to short-circuit test (e.g., IOS).  
2/ Maximum junction temperature shall not be exceeded except in accordance with allowable short  
duration burn-in screening condition in accordance with MIL-PRF-38535.  
3/ The device shall fanout in both high and low levels to the specified number of inputs of the same device  
type as that being tested.  
2
MIL-M-38510/313B  
3. REQUIREMENTS  
3.1 Qualification. Microcircuits furnished under this specification shall be products that are manufactured by a  
manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturers list before  
contract award (see 4.3 and 6.4).  
3.2 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535 and as  
specified herein or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the  
QM plan shall not affect the form, fit, or function as described herein.  
3.3 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be  
as specified in MIL-PRF-38535 and herein.  
3.3.1 Terminal connections and logic diagrams. The terminal connections and logic diagrams shall be as  
specified on figure 1.  
3.3.2 Truth tables. The truth tables shall be as specified on figure 2.  
3.3.3 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available to  
the qualifying activity and the preparing activity upon request.  
3.3.4 Case outlines. The case outlines shall be as specified in 1.2.3.  
3.4 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).  
3.5 Electrical performance characteristics. The electrical performance characteristics are as specified in table I,  
and apply over the full recommended case operating temperature range, unless otherwise specified.  
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups  
specified in table II. The electrical tests for each subgroup are described in table III.  
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.  
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group  
number 8 (see MIL-PRF-38535, appendix A).  
4. VERIFICATION  
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535  
or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall  
not effect the form, fit, or function as described herein.  
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535 and shall be conducted on all devices prior  
to qualification and quality conformance inspection. The following additional criteria shall apply:  
a. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as  
specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test  
circuit shall be maintained under document control by the device manufacturer's Technology Review  
Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or  
preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power  
dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-883.  
b. Interim and final electrical test parameters shall be as specified in table II, except interim electrical  
parameters test prior to burn-in is optional at the discretion of the manufacturer.  
c. Additional screening for space level product shall be as specified in MIL-PRF-38535.  
3
MIL-M-38510/313B  
TABLE I. Electrical performance characteristics.  
Test  
Symbol  
Conditions  
Device  
types  
Limits  
Unit  
Min  
1.4  
Max  
1.9  
-55°C TC +125°C  
unless otherwise specified  
Positive going threshold VT+  
voltage  
VCC = +5.0 V  
All  
All  
All  
All  
All  
All  
All  
All  
All  
V
V
V
V
V
V
V
V
Negative going threshold VT-  
voltage  
VCC = +5.0 V  
VCC = +5.0 V  
0.5  
0.4  
2.5  
1.0  
1.4  
Hysteresis  
H
High level output voltage VOH1  
Low level output voltage VOL1  
High level output voltage VOH2  
Low level output voltage VOL2  
VCC = +4.5 V, IOH = -.4 mA,  
VIN = +0.5 V  
VCC = +4.5 V, IOL = +4 mA,  
VIN = +1.9 V  
0.4  
VCC = +5.0 V, IOH = -.4 mA,  
VIN = +0.5 V, then +1.4 V  
VCC = +5.0 V, IOL = +4 mA,  
VIN = +1.9 V, then +1.0 V  
VCC = +4.5 V, IIN = -18 mA,  
TC = +25°C  
2.5  
0.4  
-1.5  
20  
Input clamp voltage  
VIC  
IIH1  
IIH2  
High level input current  
VCC = +5.5 V, VIN = +2.7 V  
µA  
VCC = +5.5 V, VIH = +5.5 V  
All  
100  
µA  
mA  
mA  
mA  
Low level input current  
1/  
IIL  
VCC = +5.5 V, VIN = +0.4 V  
VCC = +5.5 V, VIN = GND 2/  
VCC = +5.5 V, VIN = GND  
All  
All  
-.12  
-.36  
-100  
Short circuit output  
current  
IOS  
ICCH  
-15  
High level supply  
current (total)  
01  
02  
03  
01  
02  
03  
All  
6.0  
16.0  
11.0  
7.0  
Low level supply  
current (total)  
ICCL  
VCC = +5.5 V, VIN = 5.5 V  
mA  
21.0  
14.0  
52  
Propagation delay time  
high to low level  
tPHL  
tPLH  
VCC = +5.0 V,  
5
5
ns  
ns  
RL = 2 kΩ ±10%  
CL = 50 pF ±10%,  
Propagation delay time  
low to high level  
All  
52  
1/ For CKT E, device type 03, IIL limits are -.17 mA min and -.41 mA max.  
2/ Not more than one output should be shorted at a time.  
4
MIL-M-38510/313B  
TABLE II. Electrical test requirements.  
Subgroups (see table III)  
MIL-PRF-38535  
test requirements  
Class S  
devices  
1
Class B  
devices  
1
Interim electrical parameters  
Final electrical test parameters  
Group A test requirements  
1*, 2, 3, 9  
1*, 2, 3, 9  
1, 2, 3,  
1, 2, 3, 9,  
10, 11  
N/A  
9, 10, 11  
1, 2, 3,  
Group B electrical test parameters  
when using the method 5005 QCI option  
Group C end-point electrical parameters  
9, 10, 11  
1, 2, 3,  
1, 2, 3  
1, 2, 3  
9, 10, 11  
1, 2, 3  
Group D end-point electrical parameters  
*PDA applies to subgroup 1.  
4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.  
4.4 Technology Conformance inspection (TCI). Technology conformance inspection shall be in accordance with  
MIL-PRF-38535 and herein for groups A, B, C, and D inspections (see 4.4.1 through 4.4.4).  
4.4.1 Group A inspection. Group A inspection shall be in accordance with table III of MIL-PRF-38535 and as  
follows:  
a. Tests shall be as specified in table II herein.  
b. Subgroups 4, 5, 6, 7, and 8 shall be omitted.  
4.4.2 Group B inspection. Group B inspection shall be in accordance with table II of MIL-PRF-38535.  
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as  
follows:  
a. End-point electrical parameters shall be as specified in table II herein.  
b. The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be  
as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test  
circuit shall be maintained under document control by the device manufacturer's Technology Review  
Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or  
preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power  
dissipation, as applicable, in accordance with the intent specified in test method 1005 of MIL-STD-883.  
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535. End-point  
electrical parameters shall be as specified in table II herein.  
4.5 Methods of inspection. Methods of inspection shall be specified and as follows.  
4.5.1 Voltage and current. All voltages given are referenced to the microcircuit ground terminal. Currents given  
are conventional and positive when flowing into the referenced terminal.  
5
MIL-M-38510/313B  
FIGURE 1. Terminal connections and logic diagrams.  
6
MIL-M-38510/313B  
FIGURE 1. Terminal connections and logic diagrams - Continued.  
7
MIL-M-38510/313B  
Device type 01  
Truth table  
Input  
Output  
A
L
B
C
L
D
L
Y
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
H
L
L
L
H
H
L
L
L
H
L
L
L
H
H
H
H
L
L
H
L
L
L
H
H
L
L
H
L
L
H
H
H
H
H
H
H
H
H
L
L
L
H
H
L
L
H
L
L
H
H
H
H
H
L
L
H
H
H
Positive logic Y = ABCD  
Device type 02  
Truth table each gate  
Input  
Output  
A
L
Y
H
L
H
Positive logic Y = A  
Device type 03  
Truth table each gate  
Input  
Output  
A
B
L
Y
H
H
H
L
L
H
L
L
H
H
H
Positive logic Y = AB  
FIGURE 2. Truth tables and logic equations.  
8
MIL-M-38510/313B  
NOTES:  
1. Pulse generator characteristics: PRR 1 MHz, tI 15 ns, tO 6 ns, and ZOUT 50.  
2. CL = 50 pF ±10% including probe and jig capacitance. All diodes are 1N3064 or equivalent.  
FIGURE 3. Switching time test circuit and waveforms.  
9
TABLE III. Group A inspection for device type 01. 1/  
Cases  
A,B,C,D  
Cases  
X, 2 2/  
Test no.  
1
1
2
2
3
3
4
4
6
5
8
6
9
7
8
9
10  
14  
2B  
11  
16  
12  
18  
2C  
13  
19  
2D  
14  
20  
MIL-STD-  
883  
method  
Subgroup Symbol  
10  
12  
2Y  
13  
2A  
Measured  
terminal  
Limits  
Unit  
1A  
0.5 V  
1.9 V  
"
1B  
NC  
1C  
1D  
1.9 V  
"
1Y  
-.4 mA  
"
"
"
GND  
GND  
NC  
VCC  
4.5 V  
"
"
"
"
"
"
Min  
Max  
1
VOH1  
3006  
"
"
"
"
"
"
"
3007  
3007  
3006  
"
"
"
"
"
"
1.9 V  
0.5 V  
1.9 V  
1.9 V  
1.9 V  
1.9 V  
0.5 V  
1.9 V  
1Y  
1Y  
1Y  
1Y  
2Y  
2Y  
2Y  
2Y  
1Y  
2Y  
1Y  
1Y  
1Y  
1Y  
2Y  
2Y  
2Y  
2Y  
1Y  
2Y  
1A  
1B  
1C  
1D  
2A  
2B  
2C  
2D  
1A  
1B  
1C  
1D  
2A  
2B  
2C  
2D  
1A  
1B  
1C  
1D  
2A  
2B  
2C  
2D  
2.5  
V
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
µA  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
"
"
0.5 V  
-.4 mA  
0.5 V  
1.9 V  
"
"
1.9 V  
0.5 V  
1.9 V  
1.9 V  
1.9 V  
1.9 V  
0.5 V  
1.9 V  
1.9 V  
"
"
"
"
"
0.5 V  
"
"
"
VOL1  
VOH2  
1.9 V  
1.9 V  
1.9 V  
1.9 V  
4 mA  
0.4  
0.4  
4 mA  
1.9 V  
1.9 V  
1.9 V  
1.9 V  
3/  
1.9 V  
"
"
1.9 V  
3/  
1.9 V  
1.9 V  
1.9 V  
1.9 V  
3/  
1.9 V  
"
"
-.4 mA  
5.0 V  
"
"
"
"
"
"
"
2.5  
"
"
"
"
"
"
"
"
"
"
1.9 V  
3/  
-.4 mA  
3/  
1.9 V  
"
"
1.9 V  
3/  
1.9 V  
1.9 V  
1.9 V  
1.9 V  
3/  
1.9 V  
"
"
"
"
"
"
1.9 V  
3/  
VOL2  
VIC  
3007  
3007  
4/  
4/  
4/  
4/  
4 mA  
"
"
0.4  
0.4  
-1.5  
4 mA  
4/  
4/  
4/  
4/  
-18 mA  
4.5 V  
"
"
"
"
"
"
"
-18 mA  
"
"
"
"
"
"
"
20  
"
"
"
"
"
"
"
-18 mA  
-18 mA  
-18 mA  
-18 mA  
-18 mA  
-18 mA  
IIH1  
3010  
2.7 V  
GND  
"
"
GND  
2.7 V  
GND  
GND  
GND  
GND  
2.7 V  
GND  
GND  
"
"
5.5 V  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2.7 V  
2.7 V  
GND  
"
"
GND  
2.7 V  
GND  
GND  
GND  
GND  
2.7 V  
GND  
GND  
"
"
34  
35  
36  
37  
38  
39  
40  
41  
2.7 V  
IIH2  
5.5 V  
GND  
"
"
GND  
5.5 V  
GND  
GND  
GND  
GND  
5.5 V  
GND  
GND  
"
"
100  
"
"
"
"
"
"
"
5.5 V  
5.5 V  
GND  
"
"
GND  
5.5 V  
GND  
GND  
GND  
GND  
5.5 V  
GND  
GND  
"
"
42  
43  
44  
5.5 V  
See footnotes at end of table.  
TABLE III. Group A inspection for device type 01 – Continued. 1/  
Cases  
A,B,C,D  
1
2
2
3
3
4
4
6
5
8
6
9
7
8
9
10  
14  
2B  
11  
16  
12  
18  
2C  
13  
19  
2D  
14  
20  
MIL-STD-  
883  
method  
Cases  
X, 2 2/  
Subgroup Symbol  
10  
12  
2Y  
13  
2A  
Measured  
terminal  
Limits  
Unit  
Test no.  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
1A  
0.4 V  
5.5 V  
"
1B  
NC  
1C  
1D  
5.5 V  
"
1Y  
GND  
GND  
NC  
VCC  
5.5 V  
Min  
Max  
1
I I L  
3009  
"
"
"
"
"
"
5.5 V  
0.4 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
0.4 V  
5.5 V  
1A  
1B  
1C  
1D  
2A  
2B  
2C  
2D  
1Y  
2Y  
VCC  
VCC  
-.12  
"
"
"
"
"
"
"
-.36  
"
"
"
"
"
"
"
-100  
-100  
6.0  
7.0  
mA  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
"
"
0.4 V  
0.4 V  
5.5 V  
"
"
5.5 V  
0.4 V  
5.5 V  
5.5 V  
5.5 V  
5.5 V  
0.4 V  
5.5 V  
5.5 V  
"
"
"
0.4 V  
IOS  
3011  
3011  
3005  
3005  
GND  
GND  
GND  
GND  
GND  
-15  
-15  
GND  
GND  
GND  
5.5 V  
GND  
GND  
5.5 V  
GND  
GND  
5.5 V  
GND  
GND  
5.5 V  
ICCH  
ICCL  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
"
"
2
3
9
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125°C and VI C tests are omitted.  
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VI C tests are omitted.  
tPHL  
tPLH  
tPHL  
tPLH  
3003  
Fig. 3  
57  
58  
59  
60  
61  
62  
63  
64  
IN  
IN  
IN  
IN  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
OUT  
OUT  
OUT  
OUT  
GND  
5.0 V  
1A to 1Y  
2A to 2Y  
1A to1Y  
2A to 2Y  
1A to 1Y  
2A to 2Y  
1A to1Y  
2A to 2Y  
5
32  
ns  
"
"
"
"
"
OUT  
OUT  
OUT  
OUT  
IN  
IN  
IN  
IN  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
"
"
"
"
"
"
"
Tc = 25°C  
"
"
"
"
"
"
"
"
"
"
"
"
52  
"
"
10  
Tc = 125°C  
"
"
"
"
"
"
11  
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55°C.  
1/ Terminal conditions (pins not designated may be H 1.4 V; L 1.0 V; or open).  
2/ Case X and 2 pins not referenced are NC.  
3/ Momentary 0.5 V, then 1.4 V without overshoot during test.  
4/ Momentary 1.9 V, then 1.0 V without undershoot during test.  
TABLE III. Group A inspection for device type 02. 1/  
Cases  
A,B,C,D  
Cases  
X, 2 2/  
Test no.  
1
1
2
2
3
3
4
4
6
5
8
6
9
7
8
9
10  
14  
5Y  
11  
16  
5A  
12  
18  
6Y  
13  
19  
6A  
14  
20  
MIL-STD-  
883  
method  
Subgroup Symbol  
10  
12  
4Y  
13  
4A  
Measured  
terminal  
Limits  
Unit  
1A  
0.5 V  
1Y  
-.4 mA  
2A  
2Y  
3A  
3Y  
GND  
GND  
VCC  
4.5 V  
Min  
Max  
1
VOH1  
VOL1  
VOH2  
VOL2  
VI C  
3006  
"
"
"
"
"
3007  
"
"
"
"
"
3006  
"
"
"
"
"
1Y  
2Y  
3Y  
4Y  
5Y  
6Y  
6Y  
5Y  
4Y  
3Y  
2Y  
1Y  
1Y  
2Y  
3Y  
4Y  
5Y  
6Y  
6Y  
5Y  
4Y  
3Y  
2Y  
1Y  
1A  
2A  
3A  
4A  
5A  
6A  
6A  
5A  
4A  
3A  
2A  
1A  
1A  
2A  
3A  
4A  
5A  
6A  
6A  
5A  
4A  
3A  
2A  
1A  
2.5  
V
"
"
"
V
"
"
"
"
"
"
"
µA  
2
3
4
5
6
7
8
9
0.5 V  
-.4 mA  
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
0.5 V  
-.4 mA  
-.4 mA  
4 mA  
0.5 V  
1.9 V  
-.4 mA  
4 mA  
0.5 V  
1.9 V  
-.4 mA  
4 mA  
0.5 V  
1.9 V  
0.4 V  
"
"
"
"
"
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
1.9 V  
4 mA  
1.9 V  
3/  
4 mA  
1.9 V  
3/  
4 mA  
-.4 mA  
5.0 V  
"
4.5 V  
"
"
"
2.5  
-.4 mA  
"
"
"
"
"
3/  
-.4 mA  
-.4 mA  
4 mA  
3/  
4/  
-.4 mA  
4 mA  
3/  
4/  
-.4 mA  
4 mA  
3/  
4/  
3007  
0.4 V  
"
"
"
"
"
-1.5  
"
"
"
"
20  
"
"
"
"
"
4/  
4 mA  
4/  
4 mA  
4/  
-18 mA  
4 mA  
-18 mA  
-18 mA  
-18 mA  
2.7 V  
-18 mA  
2.7 V  
-18 mA  
2.7 V  
II H 1  
II H 2  
II L  
3010  
"
"
"
"
"
"
"
"
"
"
"
5.5 V  
"
"
"
"
2.7 V  
5.5 V  
2.7 V  
5.5 V  
2.7 V  
5.5 V  
100  
"
5.5 V  
0.4 V  
5.5 V  
0.4 V  
5.5 V  
0.4 V  
3009  
-.12  
-.36  
mA  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
0.4 V  
0.4 V  
0.4 V  
See footnotes at end of table.  
TABLE III. Group A inspection for device type 02. 1/  
Cases  
A,B,C,D  
Cases  
X, 2 2/  
Test no.  
49  
50  
51  
52  
53  
1
2
2
3
3
4
4
6
5
8
6
9
7
8
9
10  
14  
5Y  
11  
16  
5A  
12  
18  
6Y  
13  
19  
6A  
14  
20  
MIL-STD-  
883  
method  
Subgroup Symbol  
10  
12  
4Y  
13  
4A  
Measured  
terminal  
Limits  
Unit  
1A  
GND  
1Y  
GND  
2A  
2Y  
3A  
3Y  
GND  
GND  
VCC  
5.5 V  
Min  
Max  
1
IOS  
3011  
"
"
"
"
1Y  
2Y  
3Y  
4Y  
5Y  
6Y  
VC C  
VC C  
-15  
-100  
mA  
GND  
GND  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
GND  
GND  
GND  
GND  
GND  
GND  
"
54  
55  
56  
GND  
GND  
GND  
5.5 V  
IC CH  
IC CL  
3005  
3005  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
16  
21  
2
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125° C, and V I C tests are omitted.  
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55° C, and V I C tests are omitted.  
3
9
tPHL  
tPLH  
tPHL  
tPLH  
3003  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
IN  
IN  
IN  
IN  
OUT  
OUT  
OUT  
OUT  
GND  
5.0 V  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
5A to 5Y  
6A to 6Y  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
5A to 5Y  
6A to 6Y  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
5A to 5Y  
6A to 6Y  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
5A to 5Y  
6A to 6Y  
5
"
"
"
"
"
32  
ns  
Fig. 3  
IN  
IN  
IN  
IN  
OUT  
OUT  
OUT  
OUT  
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
"
IN  
IN  
IN  
IN  
OUT  
OUT  
OUT  
OUT  
"
"
OUT  
OUT  
OUT  
OUT  
IN  
IN  
IN  
IN  
"
"
OUT  
OUT  
OUT  
OUT  
IN  
IN  
IN  
IN  
"
OUT  
OUT  
OUT  
OUT  
IN  
IN  
IN  
IN  
"
"
"
"
"
"
"
"
10  
3003  
52  
"
Fig. 3  
Tc = 125°C  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
11  
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55°C.  
1/ Terminal conditions (pins not designated may be H 1.4 V; L 1.0 V; or open).  
2/ Case X and 2 pins not referenced are NC.  
3/ Momentary 0.5 V, then 1.4 V without overshoot during test.  
4/ Momentary 1.9 V, then 1.0 V without undershoot during test.  
TABLE III. Group A inspection for device type 03. 1/  
Cases  
A,B,C,D  
Cases  
X, 2 2/  
Test no.  
1
1
2
2
3
3
4
4
6
5
8
6
9
7
8
9
10  
14  
3B  
11  
16  
4Y  
12  
18  
4A  
13  
19  
4B  
14  
20  
MIL-STD-  
883  
method  
Subgroup Symbol  
10  
12  
3Y  
13  
3A  
Measured  
terminal  
Limits  
Unit  
1A  
0.5 V  
1.9 V  
1B  
1.9 V  
0.5 V  
1Y  
-.4 mA  
-.4 mA  
2A  
2B  
2Y  
GND  
GND  
VCC  
4.5 V  
"
"
"
"
"
"
"
"
"
"
Min  
Max  
1
VOH1  
3006  
"
"
"
"
"
"
"
3007  
"
"
"
3006  
"
"
"
1Y  
1Y  
2Y  
2Y  
3Y  
3Y  
4Y  
4Y  
4Y  
3Y  
2Y  
1Y  
1Y  
1Y  
2Y  
2Y  
3Y  
3Y  
4Y  
4Y  
4Y  
3Y  
2Y  
1Y  
1A  
1B  
2A  
2B  
3A  
3B  
4A  
4B  
1A  
1B  
2A  
2B  
3A  
3B  
4A  
4B  
1A  
1B  
2A  
2B  
3A  
3B  
4A  
4B  
2.5  
V
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
µA  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2
3
4
5
6
7
8
9
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
0.5 V  
1.9 V  
1.9 V  
0.5 V  
-.4 mA  
-.4 mA  
-.4 mA  
-.4 mA  
0.5 V  
1.9 V  
1.9 V  
0.5 V  
-.4 mA  
-.4 mA  
4 mA  
0.5 V  
1.9 V  
1.9 V  
1.9 V  
0.5 V  
1.9 V  
VOL1  
0.4  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
4 mA  
1.9 V  
1.9 V  
"
"
"
1.9 V  
1.9 V  
4 mA  
1.9 V  
3/  
1.9 V  
1.9 V  
1.9 V  
3/  
4 mA  
-.4 mA  
-.4 mA  
"
VOH2  
5.0 V  
"
"
"
"
"
"
"
"
"
"
"
4.5 V  
"
"
"
"
"
"
"
2.5  
"
"
"
"
"
"
"
3/  
1.9 V  
1.9 V  
3/  
-.4 mA  
-.4 mA  
"
"
"
"
-.4 mA  
-.4 mA  
3/  
1.9 V  
1.9 V  
3/  
-.4 mA  
-.4 mA  
4 mA  
3/  
1.9 V  
4/  
1.9 V  
3/  
4/  
VOL2  
3007  
0.4  
"
"
"
4 mA  
4/  
4/  
"
"
"
4/  
4/  
4 mA  
4/  
-18 mA  
4/  
4 mA  
VI C  
-1.5  
-18 mA  
"
"
"
"
"
"
"
20  
"
"
"
"
"
"
"
-18 mA  
-18 mA  
-18 mA  
-18 mA  
-18 mA  
-18 mA  
IIH1  
3010  
2.7 V  
GND  
GND  
2.7 V  
5.5 V  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2.7 V  
GND  
GND  
2.7 V  
2.7 V  
GND  
GND  
2.7 V  
2.7 V  
GND  
GND  
2.7 V  
IIH2  
5.5 V  
GND  
GND  
5.5 V  
100  
"
"
"
"
"
"
"
5.5 V  
GND  
GND  
5.5 V  
5.5 V  
GND  
GND  
5.5 V  
5.5 V  
GND  
GND  
5.5 V  
See footnotes at end of table.  
TABLE III. Group A inspection for device type 03 – Continued. 1/  
Cases  
A,B,C,D  
1
2
2
3
3
4
4
6
5
8
6
9
7
8
9
10  
14  
3B  
11  
16  
4Y  
12  
18  
4A  
13  
19  
4B  
14  
20  
MIL-STD-  
883  
method  
Cases  
X, 2 2/  
Subgroup Symbol  
10  
12  
3Y  
13  
3A  
Measured  
terminal  
Limits  
Unit  
Test no.  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
1A  
0.4 V  
5.5 V  
1B  
5.5 V  
0.4 V  
1Y  
2A  
2B  
2Y  
GND  
GND  
VCC  
5.5 V  
Min  
Max  
1
I I L  
5/  
3009  
"
"
"
"
"
"
"
1A  
1B  
2A  
2B  
3A  
3B  
4A  
4B  
1Y  
2Y  
3Y  
4Y  
VCC  
VCC  
-.12  
"
"
"
"
"
"
"
-15  
"
"
"
-.36  
"
"
"
"
"
"
"
-100  
"
"
"
mA  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
0.4 V  
5.5 V  
5.5 V  
0.4 V  
0.4 V  
5.5 V  
5.5 V  
0.4 V  
0.4 V  
5.5 V  
5.5 V  
0.4 V  
IOS  
3011  
"
"
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
"
GND  
GND  
GND  
5.5 V  
GND  
GND  
5.5 V  
ICCH  
ICCL  
3005  
3005  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
GND  
5.5 V  
11.0  
14.0  
2
3
9
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125°C and VI C tests are omitted.  
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VI C tests are omitted.  
tPHL  
tPLH  
tPHL  
tPLH  
3003  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
IN  
IN  
IN  
IN  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
OUT  
OUT  
OUT  
OUT  
GND  
5.0 V  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
1A to 1Y  
2A to 2Y  
3A to 3Y  
4A to 4Y  
5
"
"
"
"
"
"
"
"
"
"
"
32  
ns  
Fig. 3  
IN  
IN  
IN  
IN  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
OUT  
OUT  
OUT  
OUT  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
Tc = 25°C  
"
"
"
"
"
"
"
"
"
"
"
"
"
"
OUT  
OUT  
OUT  
OUT  
IN  
IN  
IN  
IN  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
"
"
"
"
OUT  
OUT  
OUT  
OUT  
IN  
IN  
IN  
IN  
5.0 V  
5.0 V  
5.0 V  
5.0 V  
"
"
"
"
"
52  
"
"
10  
Tc = 125°C  
"
"
"
"
"
"
"
"
"
"
11  
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55°C.  
1/ Terminal conditions (pins not designated may be H 1.4 V; L 1.0 V; or open).  
2/ Case X and 2 pins not referenced are NC.  
3/ Momentary 0.5 V, then 1.4 V without overshoot during test.  
4/ Momentary 1.9 V, then 1.0 V without undershoot during test.  
5/ For CKT E IIL limits are as follows, -0.17 to -0.41 mA.  
MIL-M-38510/313B  
5. PACKAGING  
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the  
contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD personnel, these  
personnel need to contact the responsible packaging activity to ascertain requisite packaging requirements.  
Packaging requirements are maintained by the Inventory Control Point's packaging activity within the Military  
Department of Defense Agency, or within the Military Department's System Command. Packaging data retrieval is  
available from the managing Military Department's or Defense Agency's automated packaging files, CD-ROM  
products, or by contacting the responsible packaging activity.  
6. NOTES  
(This section contains information of a general or explanatory nature which may be helpful, but is not  
mandatory.)  
6.1 Intended use. Microcircuits conforming to this specification are intended for original equipment design  
applications and logistic support of existing equipment.  
6.2 Acquisition requirements. Acquisition documents should specify the following:  
a. Title, number, and date of the specification.  
b. Complete part number (see 1.2).  
c. Requirements for delivery of one copy of the quality conformance inspection data pertinent to the device  
inspection lot to be supplied with each shipment by the device manufacturer, if applicable.  
d. Requirements for certificate of compliance, if applicable.  
e. Requirements for notification of change of product or process to contracting activity in addition to  
notification to the qualifying activity, if applicable.  
f. Requirements for failure analysis (including required test condition of method 5003 of MIL-STD-883),  
corrective action, and reporting of results, if applicable.  
g. Requirements for product assurance options.  
h. Requirements for special carriers, lead lengths, or lead forming, if applicable. These requirements should  
not affect the part number. Unless otherwise specified, these requirements will not apply to direct  
purchase by or direct shipment to the Government.  
j. Requirements for "JAN" marking.  
6.3 Superseding information. The requirements of MIL-M-38510 have been superseded to take advantage of the  
available Qualified Manufacturer Listing (QML) system provided by MIL-PRF-38535. Previous references to MIL-M-  
38510 in this document have been replaced by appropriate references to MIL-PRF-38535. All technical requirements  
now consist of this specification and MIL-PRF-38535. The MIL-M-38510 specification sheet number and PIN have  
been retained to avoid adversely impacting existing government logistics systems and contractor's parts lists.  
6.4 Qualification. With respect to products requiring qualification, awards will be made only for products which  
are, at the time of award of contract, qualified for inclusion in Qualified Manufacturers List QML-38535 whether or not  
such products have actually been so listed by that date. The attention of the contractors is called to these  
requirements, and manufacturers are urged to arrange to have the products that they propose to offer to the Federal  
Government tested for qualification in order that they may be eligible to be awarded contracts or purchase orders for  
the products covered by this specification. Information pertaining to qualification of products may be obtained from  
DSCC-VQ, 3990 E. Broad Street, Columbus, Ohio 43123-1199.  
16  
MIL-M-38510/313B  
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined  
in MIL-PRF-38535, MIL-HDBK-1331, and as follows:  
GND ........................................... Ground zero voltage potential  
IIN ................................................ Current flowing into an input terminal  
VIN ............................................... Voltage level at an input terminal  
6.6 Logistic support. Lead materials and finishes (see 3.4) are interchangeable. Unless otherwise specified,  
microcircuits acquired for Government logistic support will be acquired to device class B (see 1.2.2), lead material  
and finish A (see 3.4). Longer length leads and lead forming should not affect the part number.  
6.7 Substitutability. The cross-reference information below is presented for the convenience of users.  
Microcircuits covered by this specification will functionally replace the listed generic-industry type. Generic-industry  
microcircuit types may not have equivalent operational performance characteristics across military temperature  
ranges or reliability factors equivalent to MIL-M-38510 device types and may have slight physical variations in relation  
to case size. The presence of this information should not be deemed as permitting substitution of generic-industry  
types for MIL-M-38510 types or as a waiver of any of the provisions of MIL-PRF-38535.  
Military device  
Generic-industry  
type  
type  
01  
54LS13  
02  
54LS14  
03  
54LS132  
6.8 Manufacturers' designation. Manufacturers' circuits which form a part of this specification are designated with  
an "X" as shown in table IV herein.  
TABLE IV. Manufacturers' designations.  
Circuits  
Device  
type  
A
B
C
D
E
National  
Semiconductor  
Corp.  
Texas  
Instruments  
Signetics Motorola Inc.  
Corp.  
Raytheon  
Co.  
01  
02  
03  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
6.9 Changes from previous issue. Asterisks are not used in this revision to identify changes with respect to the  
previous issue due to the extensiveness of the changes.  
Custodians:  
Army - CR  
Navy - EC  
Air Force - 11  
DLA - CC  
Preparing activity:  
DLA - CC  
(Project 5962-1962)  
Review activities:  
Army - MI, SM  
Navy - AS, CG, MC, SH, TD  
Air Force - 03, 19, 99  
17  
STANDARDIZATION DOCUMENT IMPROVEMENT PROPOSAL  
INSTRUCTIONS  
1. The preparing activity must complete blocks 1, 2, 3, and 8. In block 1, both the document number and revision letter should be given.  
2. The submitter of this form must complete blocks 4, 5, 6, and 7, and send to preparing activity.  
3. The preparing activity must provide a reply within 30 days from receipt of the form.  
NOTE: This form may not be used to request copies of documents, nor to request waivers, or clarification of requirements on current contracts.  
Comments submitted on this form do not constitute or imply authorization to waive any portion of the referenced document(s) or to amend  
contractual requirements.  
1. DOCUMENT NUMBER  
MIL-M-38510/313B  
2. DOCUMENT DATE (YYYYMMDD)  
I RECOMMEND A CHANGE:  
2003-05-23  
3. DOCUMENT TITLE  
MICROCIRCUITS, DIGITAL, LOW-POWER SCHOTTKY TTL, SCHMITT TRIGGER POSITIVE NAND GATE AND  
INVERTER, MONOLITHIC SILICON  
4. NATURE OF CHANGE (Identify paragraph number and include proposed rewrite, if possible. Attach extra sheets as needed.)  
5. REASON FOR RECOMMENDATION  
6. SUBMITTER  
a. NAME (Last, First Middle Initial)  
b. ORGANIZATION  
c. ADDRESS (Include Zip Code)  
d. TELEPHONE (Include Area Code)  
(1) Commercial  
7. DATE SUBMITTED  
(YYYYMMDD)  
(2) DSN  
(If applicable)  
8. PREPARING ACTIVITY  
a. NAME  
b. TELEPHONE (Include Area Code  
Defense Supply Center, Columbus  
(1) Commercial 614-692-0536  
(2) DSN 850-0536  
c. ADDRESS (Include Zip Code)  
DSCC-VA  
IF YOU DO NOT RECEIVE A REPLY WITHIN 45 DAYS, CONTACT:  
Defense Standardization Program Office (DLSC-LM)  
8725 John J. Kingman Road, Suite 2533  
P. O. Box 3990  
Columbus, Ohio 43216-5000  
Fort Belvoir, Virginia 22060-6221  
Telephone (703)767-6888 DSN 427-6888  
DD Form 1426, FEB 1999 (EG)  
PREVIOUS EDITIONS ARE OBSOLETE.  
WHS/DIOR, Feb 99  

相关型号:

M38510/31301BCX

IC LS SERIES, DUAL 4-INPUT NAND GATE, CDIP14, CERAMIC, DIP-14, Gate
ACTEL

M38510/31301BDA

NAND Gate, LS Series, 2-Func, 4-Input, TTL, CDFP14, CERAMIC, FP-14
MOTOROLA

M38510/31301BDX

IC LS SERIES, DUAL 4-INPUT NAND GATE, CDFP14, CERAMIC, FP-14, Gate
ACTEL

M38510/31302B2C

Inverter, LS Series, 6-Func, 1-Input, TTL, CQCC20, CERAMIC, LCC-20
MOTOROLA

M38510/31302B2X

Inverter, LS Series, 6-Func, 1-Input, TTL, CQCC20, CERAMIC, LCC-20
ACTEL

M38510/31302BAX

Inverter, LS Series, 6-Func, 1-Input, TTL, CDFP14, CERAMIC, FP-14
ACTEL

M38510/31302BBA

Inverter, LS Series, 6-Func, 1-Input, TTL, CDFP14, CERAMIC, FP-14
MOTOROLA

M38510/31302BBC

Inverter, LS Series, 6-Func, 1-Input, TTL, CDFP14, CERAMIC, FP-14
MOTOROLA

M38510/31302BBX

Inverter, LS Series, 6-Func, 1-Input, TTL, CDFP14, CERAMIC, FP-14
ACTEL

M38510/31302BCA

具有施密特触发输入的军用 6 通道、4.5V 至 5.5V 双极反相器 | J | 14 | -55 to 125
TI

M38510/31302BCX

IC LS SERIES, HEX 1-INPUT INVERT GATE, CDIP14, CERAMIC, DIP-14, Gate
ACTEL

M38510/31302BDX

Inverter, LS Series, 6-Func, 1-Input, TTL, CDFP14, CERAMIC, FP-14
ACTEL