SN54LS192J [MOTOROLA]

PRESETTABLE BCD/DECADE UP/DOWN COUNTER PRESETTABLE 4-BIT BINARY UP/DOWN COUNTER; 可预置BCD / DECADE UP / DOWN COUNTER可预置4位二进制加/减计数器
SN54LS192J
型号: SN54LS192J
厂家: MOTOROLA    MOTOROLA
描述:

PRESETTABLE BCD/DECADE UP/DOWN COUNTER PRESETTABLE 4-BIT BINARY UP/DOWN COUNTER
可预置BCD / DECADE UP / DOWN COUNTER可预置4位二进制加/减计数器

计数器 CD
文件: 总9页 (文件大小:278K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SN54/74LS192  
SN54/74LS193  
PRESETTABLE BCD/DECADE  
UP/DOWN COUNTER  
PRESETTABLE 4-BIT BINARY  
UP/DOWN COUNTER  
PRESETTABLE BCD/DECADE  
UP/DOWN COUNTER  
PRESETTABLE 4-BIT BINARY  
UP/DOWN COUNTER  
The SN54/74LS192 is an UP/DOWN BCD Decade (8421) Counter and the  
SN54/74LS193 is an UP/DOWN MODULO-16 Binary Counter. Separate  
Count Up and Count Down Clocks are used and in either counting mode the  
circuits operate synchronously. The outputs change state synchronous with  
the LOW-to-HIGH transitions on the clock inputs.  
LOW POWER SCHOTTKY  
Separate Terminal Count Up and Terminal Count Down outputs are  
provided which are used as the clocks for a subsequent stages without extra  
logic, thus simplifying multistage counter designs. Individual preset inputs  
allow the circuits to be used as programmable counters. Both the Parallel  
Load (PL) and the Master Reset (MR) inputs asynchronously override the  
clocks.  
J SUFFIX  
CERAMIC  
CASE 620-09  
16  
1
Low Power . . . 95 mW Typical Dissipation  
High Speed . . . 40 MHz Typical Count Frequency  
Synchronous Counting  
Asynchronous Master Reset and Parallel Load  
Individual Preset Inputs  
N SUFFIX  
PLASTIC  
CASE 648-08  
16  
1
Cascading Circuitry Internally Provided  
Input Clamp Diodes Limit High Speed Termination Effects  
D SUFFIX  
SOIC  
CASE 751B-03  
CONNECTION DIAGRAM DIP (TOP VIEW)  
16  
1
ORDERING INFORMATION  
NOTE:  
SN54LSXXXJ  
SN74LSXXXN Plastic  
SN74LSXXXD SOIC  
Ceramic  
The Flatpak version  
has the same pinouts  
(Connection Diagram) as  
the Dual In-Line Package.  
LOGIC SYMBOL  
PIN NAMES  
LOADING (Note a)  
HIGH  
LOW  
CP  
CP  
MR  
PL  
Count Up Clock Pulse Input  
Count Down Clock Pulse Input  
Asynchronous Master Reset (Clear) Input  
Asynchronous Parallel Load (Active LOW) Input  
Parallel Data Inputs  
Flip-Flop Outputs (Note b)  
Terminal Count Down (Borrow) Output (Note b)  
Terminal Count Up (Carry) Output (Note b)  
0.5 U.L.  
0.5 U.L.  
0.5 U.L.  
0.5 U.L.  
0.5 U.L.  
10 U.L. 5 (2.5) U.L.  
10 U.L. 5 (2.5) U.L.  
10 U.L. 5 (2.5) U.L.  
0.25 U.L.  
0.25 U.L.  
0.25 U.L.  
0.25 U.L.  
0.25 U.L.  
U
D
P
Q
TC  
TC  
n
n
D
U
NOTES:  
a. 1 TTL Unit Load (U.L.) = 40 µA HIGH/1.6 mA LOW.  
b. The Output LOW drive factor is 2.5 U.L. for Military (54) and 5 U.L. for Commercial (74)  
b. Temperature Ranges.  
FAST AND LS TTL DATA  
5-351  
SN54/74LS192 SN54/74LS193  
STATE DIAGRAMS  
LS192 LOGIC EQUATIONS  
FOR TERMINAL COUNT  
TC = Q  
Q
Q
CP  
U
2
U
0
0
3
1
TC = Q  
Q
Q
CP  
3 D  
D
LS193 LOGIC EQUATIONS  
FOR TERMINAL COUNT  
TC = Q  
Q
Q
Q
Q
Q
Q
CP  
3 U  
U
0
0
1
1
2
2
TC = Q  
CP  
3 D  
D
LS192  
LS193  
LOGIC DIAGRAMS  
LS192  
FAST AND LS TTL DATA  
5-352  
SN54/74LS192 SN54/74LS193  
LOGIC DIAGRAMS (continued)  
LS193  
FAST AND LS TTL DATA  
5-353  
SN54/74LS192 SN54/74LS193  
FUNCTIONAL DESCRIPTION  
The LS192 and LS193 are Asynchronously Presettable  
Decade and 4-Bit Binary Synchronous UP/DOWN (Revers-  
able) Counters. The operating modes of the LS192 decade  
counter and the LS193 binary counter are identical, with the  
only difference being the count sequences as noted in the  
State Diagrams. Each circuit contains four master/slave  
flip-flops, with internal gating and steering logic to provide  
master reset, individual preset, count up and count down  
operations.  
Each flip-flop contains JK feedback from slave to master  
such that a LOW-to-HIGH transition on its T input causes the  
slave, and thus the Q output to change state. Synchronous  
switching, as opposed to ripple counting, is achieved by  
driving the steering gates of all stages from a common Count  
Up line and a common Count Down line, thereby causing all  
state changes to be initiated simultaneously. A LOW-to-HIGH  
transition on the Count Up input will advance the count by one;  
a similar transition on the Count Down input will decrease the  
count by one. While counting with one clock input, the other  
shouldbe held HIGH. Otherwise, the circuit will either count by  
twos or not at all, depending on the state of the first flip-flop,  
which cannot toggle as long as either Clock input is LOW.  
The Terminal Count Up (TC ) and Terminal Count Down  
U
(TC ) outputs are normally HIGH. When a circuit has reached  
D
the maximum count state (9 for the LS192, 15 for the LS193),  
the next HIGH-to-LOW transition of the Count Up Clock will  
cause TC to go LOW. TC will stay LOW until CP goes  
U
U
U
HIGH again, thus effectively repeating the Count Up Clock,  
but delayed by two gate delays. Similarly, the TC output will  
D
go LOW when the circuit is in the zero state and the Count  
Down Clock goes LOW. Since the TC outputs repeat the clock  
waveforms, they can be used as the clock input signals to the  
next higher order circuit in a multistage counter.  
Each circuit has an asynchronous parallel load capability  
permitting the counter to be preset. When the Parallel Load  
(PL) and the Master Reset (MR) inputs are LOW, information  
present on the Parallel Data inputs (P , P ) is loaded into the  
0
3
counter and appears on the outputs regardless of the  
conditions of the clock inputs. A HIGH signal on the Master  
Reset input will disable the preset gates, override both Clock  
inputs, and latch each Q output in the LOW state. If one of the  
Clock inputs is LOW during and after a reset or load operation,  
the next LOW-to-HIGH transition of that Clock will be  
interpreted as a legitimate signal and will be counted.  
MODE SELECT TABLE  
MR  
PL  
CP  
CP  
MODE  
U
D
H
L
L
L
L
X
L
H
H
H
X
X
H
X
X
H
H
Reset (Asyn.)  
Preset (Asyn.)  
No Change  
Count Up  
H
Count Down  
L = LOW Voltage Level  
H = HIGH Voltage Level  
X = Don’t Care  
= LOW-to-HIGH Clock Transition  
FAST AND LS TTL DATA  
5-354  
SN54/74LS192 SN54/74LS193  
GUARANTEED OPERATING RANGES  
Symbol  
Parameter  
Min  
Typ  
Max  
Unit  
V
CC  
Supply Voltage  
54  
74  
4.5  
4.75  
5.0  
5.0  
5.5  
5.25  
V
T
A
Operating Ambient Temperature Range  
54  
74  
55  
0
25  
25  
125  
70  
°C  
I
I
Output Current — High  
Output Current — Low  
54, 74  
0.4  
mA  
mA  
OH  
54  
74  
4.0  
8.0  
OL  
DC CHARACTERISTICS OVER OPERATING TEMPERATURE RANGE (unless otherwise specified)  
Limits  
Min  
Typ  
Max  
Symbol  
Parameter  
Input HIGH Voltage  
Unit  
Test Conditions  
Guaranteed Input HIGH Voltage for  
All Inputs  
V
2.0  
V
IH  
54  
74  
0.7  
0.8  
Guaranteed Input LOW Voltage for  
All Inputs  
V
V
V
Input LOW Voltage  
V
IL  
Input Clamp Diode Voltage  
Output HIGH Voltage  
0.65  
3.5  
1.5  
V
V
V
V
V
= MIN, I = 18 mA  
IN  
IK  
CC  
54  
74  
2.5  
2.7  
= MIN, I  
OH  
= MAX, V = V  
IN  
CC  
IH  
OH  
or V per Truth Table  
IL  
3.5  
V
V
= V  
CC  
MIN,  
= V or V  
IL IH  
54, 74  
74  
0.25  
0.35  
0.4  
0.5  
V
V
I
I
= 4.0 mA  
= 8.0 mA  
CC  
IN  
OL  
V
Output LOW Voltage  
Input HIGH Current  
OL  
per Truth Table  
OL  
20  
0.1  
µA  
mA  
mA  
mA  
mA  
V
V
V
V
V
= MAX, V = 2.7 V  
IN  
CC  
CC  
CC  
CC  
CC  
I
IH  
= MAX, V = 7.0 V  
IN  
I
I
I
Input LOW Current  
0.4  
100  
34  
= MAX, V = 0.4 V  
IN  
IL  
Short Circuit Current (Note 1)  
Power Supply Current  
20  
= MAX  
= MAX  
OS  
CC  
Note 1: Not more than one output should be shorted at a time, nor for more than 1 second.  
AC CHARACTERISTICS (T = 25°C)  
A
Limits  
Typ  
Symbol  
Parameter  
Unit  
Test Conditions  
Min  
Max  
f
Maximum Clock Frequency  
25  
32  
MHz  
MAX  
t
t
CP Input to  
17  
18  
26  
24  
PLH  
PHL  
U
ns  
ns  
ns  
TC Output  
U
t
t
CP Input to  
16  
15  
24  
24  
PLH  
PHL  
D
TC Output  
D
V
C
= 5.0 V  
CC  
= 15 pF  
L
t
t
27  
30  
38  
47  
PLH  
PHL  
Clock to Q  
t
t
24  
25  
40  
40  
PLH  
PHL  
PL to Q  
ns  
ns  
t
MR Input to Any Output  
23  
35  
PHL  
FAST AND LS TTL DATA  
5-355  
SN54/74LS192 SN54/74LS193  
AC SETUP REQUIREMENTS (T = 25°C)  
A
Limits  
Typ  
Symbol  
Parameter  
Unit  
ns  
Test Conditions  
Min  
20  
Max  
t
t
t
t
Any Pulse Width  
W
Data Setup Time  
Data Hold Time  
Recovery Time  
20  
ns  
s
V
CC  
= 5.0 V  
5.0  
40  
ns  
h
ns  
rec  
DEFINITIONS OF TERMS  
SETUP TIME (t ) is defined as the minimum time required for  
s
tion. A negative HOLD TIME indicates that the correct logic  
level may be released prior to the PL transition from  
LOW-to-HIGH and still be recognized.  
thecorrectlogicleveltobepresentatthelogicinputpriortothe  
PLtransitionfromLOW-to-HIGHinordertoberecognizedand  
transferred to the outputs.  
RECOVERY TIME (t ) is defined as the minimum time  
rec  
HOLD TIME (t ) is defined as the minimum time following the  
h
PL transition from LOW-to-HIGH that the logic level must be  
maintained at the input in order to ensure continued recogni-  
required between the end of the reset pulse and the clock  
transition from LOW-to-HIGH in order to recognize and  
transfer HIGH data to the Q outputs.  
FAST AND LS TTL DATA  
5-356  
SN54/74LS192 SN54/74LS193  
AC WAVEFORMS  
Figure 1  
NOTE: PL = LOW  
Figure 2  
Figure 3  
Figure 4  
Figure 5  
* The shaded areas indicate when the input is permitted  
* to change for predictable output performance  
Figure 6  
Figure 7  
FAST AND LS TTL DATA  
5-357  
Case 751B-03 D Suffix  
16-Pin Plastic  
SO-16  
-A-  
16  
1
9
8
P
C
-B-  
R X 45°  
G
-T-  
J
M
F
D
°
°
°
°
K
Case 648-08 N Suffix  
16-Pin Plastic  
-A-  
16  
1
9
B
S
8
F
L
C
K
-T-  
M
H
J
G
D
°
°
°
°
Case 620-09 J Suffix  
16-Pin Ceramic Dual In-Line  
-A-  
16  
9
-B-  
1
8
L
C
-T-  
K
M
N
E
J
F
G
D
°
°
°
°
FAST AND LS TTL DATA  
5-358  
Motorolareserves the right to make changes without further notice to any products herein. Motorola makes no warranty, representationorguaranteeregarding  
the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit,  
andspecifically disclaims any and all liability, includingwithoutlimitationconsequentialorincidentaldamages. “Typical” parameters can and do vary in different  
applications. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. Motorola does  
not convey any license under its patent rights nor the rights of others. Motorola products are not designed, intended, or authorized for use as components in  
systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of  
the Motorola product could create a situation where personal injury or death may occur. Should Buyer purchase or use Motorola products for any such  
unintendedor unauthorized application, Buyer shall indemnify and hold Motorola and its officers, employees, subsidiaries, affiliates, and distributors harmless  
against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death  
associated with such unintended or unauthorized use, even if such claim alleges that Motorola was negligent regarding the design or manufacture of the part.  
Motorola and  
are registered trademarks of Motorola, Inc. Motorola, Inc. is an Equal Opportunity/Affirmative Action Employer.  
Literature Distribution Centers:  
USA: Motorola Literature Distribution; P.O. Box 20912; Phoenix, Arizona 85036.  
EUROPE: Motorola Ltd.; European Literature Centre; 88 Tanners Drive, Blakelands, Milton Keynes, MK14 5BP, England.  
JAPAN: Nippon Motorola Ltd.; 4-32-1, Nishi-Gotanda, Shinagawa-ku, Tokyo 141, Japan.  
ASIA PACIFIC: Motorola Semiconductors H.K. Ltd.; Silicon Harbour Center, No. 2 Dai King Street, Tai Po Industrial Estate, Tai Po, N.T., Hong Kong.  

相关型号:

SN54LS192J-00

LS SERIES, SYN POSITIVE EDGE TRIGGERED 4-BIT BIDIRECTIONAL DECADE COUNTER, CDIP16
TI

SN54LS192JD

Decade Counter, LS Series, Synchronous, Positive Edge Triggered, 4-Bit, Bidirectional, TTL, CDIP16, CERAMIC, DIP-16
MOTOROLA

SN54LS192W

SYNCHRONOUS 4-BIT UP/DOWN COUNTERS (DUAL CLOCK WITH CLEAR)
TI

SN54LS192W

Decade Counter, Synchronous, Bidirectional, TTL, CDFP16,
MOTOROLA

SN54LS192W-00

LS SERIES, SYN POSITIVE EDGE TRIGGERED 4-BIT BIDIRECTIONAL DECADE COUNTER, CDFP16
TI

SN54LS193

SYNCHRONOUS 4-BIT UP/DOWN COUNTERS (DUAL CLOCK WITH CLEAR)
TI

SN54LS193-SP

SYNCHRONOUS 4-BIT UP/DOWN COUNTERS
TI

SN54LS193FK

SYNCHRONOUS 4-BIT UP/DOWN COUNTERS (DUAL CLOCK WITH CLEAR)
TI

SN54LS193J

PRESETTABLE BCD/DECADE UP/DOWN COUNTER PRESETTABLE 4-BIT BINARY UP/DOWN COUNTER
MOTOROLA

SN54LS193J

PRESETTABLE BCD/DECADE UP/DOWN COUNTER PRESETTABLE 4-BIT BINARY UP/DOWN COUNTER
ONSEMI

SN54LS193J

SYNCHRONOUS 4-BIT UP/DOWN COUNTERS (DUAL CLOCK WITH CLEAR)
TI

SN54LS193J-00

LS SERIES, SYN POSITIVE EDGE TRIGGERED 4-BIT BIDIRECTIONAL BINARY COUNTER, CDIP16
TI